Loading...
HomeMy WebLinkAboutPRODUCT APPROVALI, 11312019, Professional Regulation SCIS Home I Log In I User Registration I Hot Topics Florida Building Code Online pfawwn fY2t/' W1_ �� Submit Surcharge I Stats&Facts I Publications I Contact Us I BCLS Site Map I 11n1c9 I Search I d r � �IIProduct Approval b USER: Public User product Aopmval Menu > Product or Application Search > Aopliwnon List > Application Dothan FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method SCANNED BY St. Lucie County FL11651-R3 Revision RECEIVED 2017 Approved JAN 0 4 2019 O ST. Lucie County,,,.Fermitting Gulf Coast Supply & Manufacturing, LLC. I a67'/ —cp0r17 4020 S. W. 449th Street ST. LUCIE COU Horseshoe Beach, FL 32648 (352) 498-0778 BUILDING DIVIt Info@gulfcoastsupply.com REVAEW56 FOR COMP IAI REVIEWE Eng David DATE Info@gulfcoastsupply.com r„ „.,••,_ __- David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352) 498-0778 lnfo@gulfcoastsupply.com David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 david.eng@gulfcoastsupply.com Roofing Metal Roofing MUST BE KEPT ON J03 OR NO INSPECTION WILL IE MADE I THESE PIANS AND -ALL PROPOSED WORK ARE SUMOT TO ANY CORRECTIONS REQUIItED.®Y FlEL4.INBPECTORS TI IAT WY BE NECESSARY IN ORDER TO WITH ALL APPLICAHE CODES. XHC%EED FASTENERS ORAITACHMEHTS ARE THE RESpOHSIgIL7y OF THE CONNCTOR OF RECORD Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer C Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Daniel S. Kuhn Evaluation Report Florida Ucense Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence PE-75519 Keystone Certifications, Inc. 04/12/2024 Locke Bowden P.E. t t Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year FM 4471 1992 TAS 100 1995 FILE20 UL 1897 L UL580 - 2006 hftps://www.floddabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgsQFc5K°/p2frrZeCSHgw99R5wgrf9OEegvkzBZ4cWkSTfwnAa/a3d0/p3d 1/3 •1/3/2019, Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page 1 Method 1 Option D 10/10/2017 10/12/2017 10/17/2017 12/12/2017 00 Page2/200 FL # Model, Number or Name Description 11651.21 26 Ga. GulfRib Min 26 Ga. GulfRib over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 21 R3 Metal Roof Panel Detail - Lfgned.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-164.2PSF Created by Independent Third Party: Yes Other:-109.25 psf @ 24" o.c. fastener spacing.-164.25 psf @ Evaluation Reports 12" fastener spacing. Install per manufacturer's details. Not for FL11651 R3 AE FL11651 21 R3 26GulfRib 1x4 15- 32P1y_wood NonHVHZ-signed.odf use in HVHZ Zones Created by Independent Third Party: Yes 11651.22 26 Ga. GulfRib Min 26 Ga. Gulflub over 15/32" Plywood Limits of Use Installation Instructions Approved for use In HVHZ: No FL11651 R3 I1 FL11651 22 R3 Metal Roof Panel Detail - 5[gned.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-159.2PSF Created by Independent Third Party: Yes Other: -69.25 psf @ 24" o.c. fastener spacing.-159.25 psf @ Evaluation Reports 12" fastener spacing. Install per manufacturer's details. Not for FL11651 R3 AE FL11651 22 R3 26GulfRib 15- use In HVHZ Zones 3Iywood NonHVHZ-sicned.odf Created by Independent Third Party: Yes 11651.23 26 Ga. GulfRib Min 26 Ga. GulfRib over 15/32" P od Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R3 11 FL11651 23 R3 Metal Rof Panel D II - Ligerl d.pdF Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-159.2PSF Created by Independent Third Party: Yes Other: -71.75 psf @ 24" o.c. fastener spacing.-159.25 psf @ Evaluation Reports 12" fastener spacing. Install per manufacturer's details. For use FL11651 R3 AE FL11651 R3 26GulfRib S- in HVHZ Zones 2P ywcod HVHZ-slgne .0f, Created by Independent Third Pa 11651.24 26 Ga. GulfRlb Min 26 Ga. GulfRib over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes FL11651 R3 IT FL11651 24 R3 Metal Roof Panel Detail - aigned.odf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-164.2PSF Created by Independent Third Party: Yes Other:-106.75 psf @ 24" o.c. fastener spacing.-164.25 psf @ Evaluation Reports 12" fastener spacing. Install per manufacturer's details. For use FL11651 R3 AE FL11651 24 R3 26GulfRib Ix4 15- 3M1ywood HVHZ-signP .gi in HVHZ Zones Created by Independent Third Party: Yes 11651.25 29 Ga. GulfRib Min 29 Ga. GulfRib over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 11 FL11651 25 R3 Metal Roof Panel Detail - ,@Igned. d Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-123.5PSF Created by Independent Third Party: Yes Other: -76.7S psf @ 24" o.c. fastener spacing. -123.5 psf @ Evaluation Reports 24" fastener spacing. Install per manufacturer's details. Not for FL11651 R3 AE FL11651 25 R3 29GuIfRib Sx4 15- use in HVHZ Zones https://www.flofldabuilding.orglpr/pr app_oti.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5wgrf9OEegvkzBZ4cWkSTfwnA%3d%3d 2/3 ,1/3/2019, -- Florida Building Code Online 32Plyw2od NorAv Z-slgned.pd Created by Independent Third Party: Yes 11651.26 29 Ga. GulfRib Min 29 Ga. GuifRib over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 26 R3 Metal Roof Panel Detail - 5igned.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-146.OPSF Created by Independent Third Party: Yes Other: -71.75 psf @ 24" o.c. fastener spacing. -146.0 psf @ Evaluation Reports 12" fastener spacing. Install per manufacturer's details. Not for FL11651 R3 AE FL11651 26 R3 29Gulflub IS - use in HVHZ Zones 32Plywood NonHVHZ-signed.odf Created by Independent Third Party: Yes 11651.27 29 Ga. Gulfwb Min 29 Ga. GulfRib over 1x4 Wood Purlins over 7/16" O.S.B. Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 11 EL11651 27 R3 Metal Roof Panel Detail - sicined.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-301.OPSF Created by Independent Third Party: Yes Other: -101.0 psf @ 24" o.c, fastener spacing. Install per Evaluation Reports manufacturer's details. Not for use In HVHZ Zones FL11651 R3 AE FL11651 27 R3 29GuIfRib Ix4 NonHVHZ- slJc ned.Odf Created by Independent Third Party: Yes 11651.28 29 Ga, GUlfRib Min 29 Ga. GulfRlb over 7/16" O.S.B. Limps of Use Installation Instructions Approved for use In HVHZ: No FL11651 R3 II FL11651 28 R3 Metal Roof Panel Detail - �IgLleQpdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-116.OPSF Created by Independent Third Party: Yes Other: -22.66 psf @ 24" o.c. fastener spacing. -116.0 psf @ Evaluation Reports 6" fastener spacing. Install per manufacturer's details. Not for FL11651 R3 AE FL11651 28 R3 29GulfRib 7- use in HVHZ Zones 16QS8 NonHVHZ-signed.pd Created by Independent Third Party: Yes Go to Page Back Ncxt 00 Page2/200 Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an WEED employer. Ciipmdght 2007-2013 State of Florida.:: Privacy Statement :: Acc ssiblllty, Statement :: Refund Statement Under Florida law, email addresses arc public records. If you do not want your e-mail address released in response to a public -records inquest, do not send electronic mail to this entry. Instead, mntact the office by phone or by trzdltlonal mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ,® ® �� M Credit Card Safe https:lhvww.flo6dabuilding.org/pdpr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw9gR5wgrf9OEegvkzBZ4GWkSTNirA°/p3d%3d 3/3 1212012018 aCls MPme Log In user Regiunatlon not Tapia Florida Building Code Online YMrr.I t rod; = Submit Surcharge $Wts & Facts Publications 1 contact us SCIS Sire Map Links Search Oiildt,�J ( >t9 Product Approval 10 r USER: Public User RECEIVED Pmaan APPrueal Menu > Pr rtNrt nr A II111fallcn Search > A;InII It > ApPllaetion netPll ;- _— — JAN 0 4 93'9 " I FL # FL20853-112 Application Type Revision ST. Lucie County, Permitting Code Version 2017 -- Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the.POC and/or the Commission If necessary. Comments Archived Product Manufacturer FT Synthetics Inc. V c'q I v4�'D Address/Phone/Email 13120 76 Ave Unit I St L Sy Surrey, NON -US 98225 UC%� (604) 594-3439 CopntY rrobson@ftsyn.com !' Authorized Signature Russ Robson rrobson@ftsyn.com Technical Representative Russ Robson Address/Phone/Email 12179 86 Ave Surrey, NON -US 00000 (604) 594-3439 rrobson@ftsyn.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity Intertek Testing Services NA, Inc. Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 01/01/2020 Validated By Intertek Testing Services NA, Inc. Certificate of Independence Referenced Standard and Year (of Standard) Standard Year ASTM D226 2009 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I Option C FILE, COPY hhps:l/www.floridabuilding.org/prfpr_app_dti,aspx?pamm=wGEVXOwtDglbxPgODTr%2bXl%2fn2hm4SoVST9TdomZjJ6ejBsbJRYLOVA%3d%3d 'I/2 12/20/2018 Florida Building Code Online Date Submitted 01/08/2018 Date Validated 01/10/2018 Date Pending FBC Approval Date Approved 01/14/2018 r.—Suinmary of Products FL _ Modelr Number or Name 20853.1 I FT Synthetles Roof Undedayments Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A - Other: 00 may_—. Description L Synthetic Roofing Unclorlayrinent Installation Instrucos Created by Evaluation tertek Te9 ng Services NA, Inc. lependegrThind Party: port EfIPIS-011-01 CCRR-102B.pdI Contact Us:: 2601 Slab Stone 110od, Tallahassee FL 32399 Monet 060-487-1024 The Slate of Florida is a0 WEED employer.'r"_dght 2002-2013 State of Florida,f: Pdve v. Statement:: dttasslbility Statement :: Refund Statement Under Florida low, en,all addresses are public records. If you do not want your a -mall address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by trachlonal mall. If you have any questions, please contact 850.482.1395. *Pursuant to Section 455.275(1)i Florida Statures, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emads provided may M used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Deportment with an email address which can be made available to the public. To determine R you are a licensee under Chapter 455, F.S., please click here . product Approval Accepts: ® rtrF] Credo Gerd Safe I httpsJ/www.floridabuilding.orglpr/pr_app_dtl.aspx?param=wGEVXQwtDgtbxPgODTr'12bXI/2m2hm4SOV8T9TdomZjJ6ejBsbjRYLOVA%3d%3d 212