Loading...
HomeMy WebLinkAboutCERTIFICATION LETTERJ r **�l (S) 360 14th Street Phone 724-266-6484 Ambridge, PA 15003 Fax 724-266-6510 LETTER OF CERTIFICATION 8/7/2018 Re: Sukup Steel Structures Job No. 20619 STEFANI/JONES 1202 WEST WEATHERBEE ROAD FORT PIERCE FL 34982 Bldg. A: 25 ft Wide x 50 ft Long x 17 ft E.H., 2.0:12 Roof Slope Bldg. B: 12 ft Wide x 50 ft Long x 15 ft E.H., 2.0:12 Roof Slope RF�F2 a ✓qN 0 Fa a� A10 O Uc/U �pU4 EY PUt SCANNE® By St. Lucie County To Whom It May Concern: This is to certify that the above referenced building is designed in accordance with the following Loads and building Code AISC10 and AISI S 100-12 specifications. The load combinations used for design are from the applicable section of the building code listed below. All welding is per the American Welding Society (AWS) specifications. Loads are applied in accordance with the Metal Building Manufacturers Association standard "Metal Building Systems Manual," latest edition unless otherwise noted below. Design Code FBC 2017 Building Risk Category II (Is = Dead Load 2.2 psf Live Load 20 psf Snow Design Data Ground Snow Load (Pg) 0.00 psf Roof Snow Load (Pr) 0.00 psf Snow Exposure Factor (Ce) 1.00 Thermal Factor (Ct) 1.00 Maximum Snow Drift Load N/A Earthquake Design Data 1.00 Ie= 1.00 ) Collateral Load 1 psf Trib. Reduction No Wind Design Data Ultimate Wind Exposure Enclosure Internal Pressure Coeff Basic Design Pressure Mapped Spectral Response Acceleration Ss = 0.055 Sl = 0.029 Spectral Response Coefficients Sds = 0.059 Shc = 0.046 Site Class D Seismic Design Category A Design Base Shear V = Cs * W 161 mph C Closed 0.18 / -0.18 49.07 Seismic Response Modification Coefficients Cs (OMRF) = 0.020 Cs (OCBF) = 0.020 Response Modification Factors R (OMRF) = 3.00 R (OCBF) = 3.00 Basic Force resisting system Ordinary Steel Moment Frame Analysis Procedure Used Equivalent Lateral Force Procedure Other Loads All framed openings are designed to support a maximum of 5 psf Door/Accessory Weight Mezzanine N/A DL ----- psf LL ----- psf Crane N/A Capacity ----- ton This Letter of Certification applies solely to the building and its component parts as furnished by Sukup Steel Structures and specifically excludes any foundation, masonry, or general contract work to include erection certification. The design and certification for this project is in accordance with the provisions and loads specified on the building order. The buyer is responsible to verify that the specified loads are in compliance with the local regulatory authorities. Sincerely, Christopher Jones P.E. * No. 83864 E-* -o ATATE OF psf +nntum-, — AUG 14 2018