Loading...
HomeMy WebLinkAboutFIELD WITHDRAWAL RESISTANCE TEST RESULTS REPORT., ,I REC FE 118 2099 ST. Lucie County, Perndtting TESTING APPLICATION STANDARD (TAS)105 - - - APPENDIX A FLORIDA BUILDING CODE FIELD WITHDRAWAL RESISTANCE TEST RESULTS REPORT FILE COPY SCANNED Test Date: February8n', 2019 BY File #: 1111-19 6��v5�4 t. Lucie County GENERAL INFORMATION Job. Name: Schuler Residence — Residential Flat Deck.Clg C UNV BUILDING D REVIEWED FOR COM LIANC l Job Address: 2405 Elizabeth Avenue. REVI Y Fort Pierce, Florida DAT PLAN AN ERMIT MUST BE KEPT JOB SITE OR NO INSPECTION(5) WIL MADE Job Contact: Tim Sutton —The Roof Authority, Inc. TESTING AGENCY AND EQUIPMENT INFORMATION Note: The Undersigned representative agrees that all testing has been conducted and results have been reported in compliance with Florida Building Code TAS 105 or TAS 105 A. Testing Agency Name: A. Tomassi Roof Testing Inc. Address: 5451 NW 24" Street, Suite # 3 Margate, Florida 33063 Telephone: (954) 979 - 1180 Fax: 954 979 - 1182 THESE PLANS AND ALL PROPOSED WO ARE SUBJECT TO ANY CORRECTIONS Lab C61EIIMtIRED BY FIELD INSPECTORS THATAnthony Tomassi Pd1AY BE NECESSARY IN ORDER TO ..PLY IM ITH ALL APPLICABLE CODES. ReporMview: Dominick Scarfo Title: Architect, AR0010248 Signature: a Pl, lti� Test Apparatus: DMD PFT — 2000A Dade County Certified Testing Agency # 17-0719.01 Revises # 03-0317.03 Page —1 Building and Roof System Information Area = #1 Height =10' ft Ht. approx. Length = 27' approx. Second largest dimension =12' approx. Total roof area = 313 square feet approx. Perimeter Area = 234 square feet approx. Page 2 FASTENER INSTALLATION INFORMATION: Is the fastener a self — driller? Yes If `yes' list the type of tool used for installation: Craftsman Speed of Tool 0 — 2,000 RPMs TEST INFORMATION: Number of Tests Conducted: n =10 * See Section 7 of Dade County PA 105 or PA 105A * Note the locations of all tests on `Building Information' Detail # 2 Attached Page 3 a FIELD WITHDRAWAL RESISTANCE TEST -RECORDING SHEET - Area = #1 Component to be secured: Insulation Existing Roof Membrane Anchor or Base Sheet Wood Blocking Metal Profiles Fastener Type: #14 Fasteners MFGR. DekFast Deck Type: Plywood Pre - Drilled No Drill Bit Size N/A Hole Depth N/A Sample No. Plan Identifier Initial Failure Load lb Field Test Area Perimeter Test Area Corner Test Area 41 same 491 X #2 266 X #3 468 X #4 382 X #5 421 X #6 492 X #7 479 X #8 489 X #9 343 X #10 387 X Page 4 STATISTICAL ANALYSIS Area = #1 --- Mean Failure Load: F = 421.80 Ibf Sample Standard Deviation: Sf = 72.74 lbf Minimum Characteristic Resistance Force: F'= 369.76 Ibf Notes: 1. Use the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined on FLORIDA BUILDING CODE TAS —117, Shall utilize the minimum characteristic force (F'), determined in compliance with section 8 of TAS 105. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105 or TAS 195(A) - 2. A safety factor of 2 to 1 shall be applied to laboratory testing, 3. The following pages shall be completed for each roof area and included with all Field Withdrawal Resistance Test Recording Sheets. Notes: ROOF AREA = #1 Insert Building and Parapet Heights. If no Parapet exists, insert C N/A") GROUND LEVEL Page 5 27' 12' T-1 T4 T-S T-5 T-2 T-9 T-6 T-3 T-7 T-10 Note: All Dimensions are Approximate —Drawing NTS ATRT Title Project: A. Tomassi Roof Testing, Inc. 5451 NW 24TR Street, Suite # 3 Margate, Florida 33063 Project No. 1111-19 I Fastener Withdrawal Test Schuler Residence 2405 Elizabeth Avenue Fort Pierce, Florida Drawn Sheet No. D.G.Z I of 1 TAS 105 - Test locations T = Tested Locations