Loading...
HomeMy WebLinkAboutSCREEN ENCLOSURE DETAILSL (2)-fIOx2' SALS. R(iOscN6N' ROSS ) 012a3/4' S.W.S. DEAN OR SLOPED) (4) #Ib3/4' SU.S.J EACH Lm 3' w 7- SUPER GUTTER Hm 0090' THICK );'ea3' LG a EACH ANfd F MOTES R ATTAOR C@IVEN / FACIA TO BE Ba O1DL) SPF. DVERxaNUTED l R WESTER RED CEDAR STRLCTIRTAL GRADE 2 TDn U) J eat' LG LAD SCREW a 24' C.C.ENiee: LENGTH M GUTTER SECURE FASCIA TO EACH RAFTER TAIL W/ C) KNIa4- LONG PAN HEAD LAG SCREWS' BEFORE ATTACHING SUPER GUTTER USE /IW%' SIM O 24' C.C. - To CONMECTT TO lag OS. TO 20. (OR) C) YNa2' LG LAC SCREWS (TYP. a EACH BEAR) lag O.B FASTENED TO COWNN/PC: C) e12a2' SAS a 12' ma W/(2) /IOa1$ SYS. R(TO SCREW BOSS (MATU IS BEANS (Gtl1 �. m — Na' THICK CONTINUOUS If i10aS/4' O 2' O.C. �� -=• I - -,' AN STITOONO SCREWS (SEE TABLE) 2 24o G f gM SPLICE PLATE SIDEQUA IF BEAR) p 388E-H32 ALLOYY aR OA EQUAL, VB' TIQOWESS _ -\\\ O{pl 111404' SCREWS � (m) I (v) I (NOW) (eni -LINE LINE SCREWS PLAT siF.'1 Owv) ,a�la ��� BEAM A •B'l'C' TAL VIDT lh �4�,F�' 2x4 3 2 24 12' t 2K5 3 3 32. 14- --X—�3` -_40� a14_' M 2a8 5 5 64 16' 2x9 5 6 72 IB' ROOF BEAM zS7 6 7 Be IF z CONNECTION DETAIL 2.1B 7 7 96 - 716' YN. (4) JIW- LONG S.W.S. D(TO - LE®P e (3)) /L2dj- 3.W.3.. FAOI LEG AND 9CREW D0536 (1)P. ALTF19(ATNE) (6) I19dj' S.W.S. pNMVa TO BEAN/ \�(R7 SCREW =AL eDIY TOP AND BOTTOM 2C O.0 �(EE TOP AND IZES) OF SYB SEE TABLE FOR sTELS) CHAIR RAIL / GIRT TO POST CONNECTION DETAIL PURUN FASTENED TO COLUYN/POSf MRRI (44)MT EAR BENT) IIW* SITS. (EACH AEG) IroN� t806)-TBALL" B 2a3:m FAYETWL ATTACKED ro BEAM WITH (])-PlGxr SL.S D(TO SCREW BOSS. _. SINS. O 24' O.C. TO 14 O.B. TO 2.3. +7I S.YS. EACH SIDE Y Ow) OR r7j' SYS. EACH SIDE J i0R 2d COLUYN TO .1.1, ' BY 3' LONG ANGLE; EACH SIDE (LEG (6)3 SM TAL PURLIN TO ROOF BEAM CONNECTION DETAIL Y MD4. 3 1¢' MAX C-C ALDG OF FASTENTRT (TYPJ 75 NIK REAM EWE DISTANCE (TTPJ OR MT STEER DO KIM & ASSDCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tempe, FL 33670 Tet (813) 374-0321 wm tR� f.—I o 15 C O W G D U O J U w � W Z W Z K a o I_ J � a U C3 BY t. Lucie County DO YEON KIM, P.E. FLA. REG. NUMBER45497 DO KIM SOCIIETES, LLC UBBer P Box 10039 Tampa, FL 33M rt, tq•Lj Drawing No. - 060811 SHEET 1OF3 G9 a 3- MIN. (TIP.) SEE PLAN FOR lag GS. FASTENED TO I SECTION WITH /14.%'? 24' O.C. i) SIDE) &MS. WITH MIN. EDGE O(SIANCE 5-1—A TOE y4le 4N EDGE OF SUPPORT—'- -�`•- a — - 1/PO 2 1/6' a 2' I.G. ANGLE W/ (4) JIW/4- S.MS S.MS. EATK MIN. )§• EDGE DISTANCE (EACH SIDS i6Y CONCRETE ANCHOR W/2i!• EMBEDMENT ORO BDNCNkLL CONCRETE (EACHSIX) N - ANGLE EACH SIDE (TTP.) %10 CONCRETE ANCHOR W/2)6' EMBEDMENT IKTO STRUMRAL CONCRETE (IYP., SEE NOTE 10) ,I-W O.B. SDLE PLATE COLUMN/POST- 1a2 O.B. SOD 1 1' CTYPJ 1 N 0 P:�4 )(1' ANGLE EACH SIDE DYP.) �36`0 CONCRETE ANCHOR W/2%' EYBEDME INTO MU07MRAL CONCRETE DYP, (���EEEE NOTE`) � 15Q•� SIXE PATE 2.a AND 9- FROM 1.2 OS. SOLE BFAW SUPPORT COWMN/POST 2 1/6' a 2' LC. ANGLE W/, (4) /12z3/4- S.M.S BEW MAY BE MT OR SLOPED � 1 BOLT, WITH OFED� ATTACHED TOBEA ATTACHED IXNGON ( AATTACHEDATTACHEDTO m Ra RI 2 .093 BRACE / (SEE PLAN) AT W Oa FASTENED TO CORNER SECTION WITH I10a2' S.Ms. W/ V ROOF '%• CTT. WASHER a 16' O.C. LE COPY COLUMN 2K' MAX. YKK]( BRIM PAWLS SET IN MORTAR ON TOP OF FOGIFN G1A i N Yi Ad' CONCRETE SCREWS O 2P D.C. 2%' MIN. CONIC. (M.). IYA' CONC. EMBEDMENT (MIN.) EMBEDMENT CrYP.) TYPCIAL FRONT VIEW OF POST TO FOUNDATION CONNECTION WITH PAVERS ANGLE Or LOW Y, :114 INTO TOP OF 24 EA.L � AND C2)- T(S INTO THE FRONT DF THE CORNER POST 1a2 O.B. TOP iRAME NER POST O.B. 510E WALL COINER UPRGM ELEVATION VIEW CORNER POST/ COLUMN UPRIGHT DETAIL DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tempe. FL 33679 Tel: (813) 374-0321 TevlDrD C>esai goon n ;a lssueD III.II ;II.�I lL- ILL- . , .: „ •. II71 • III.�I.1 r ':RI . 1- z V W MIN. CONTINUOUS PERIMETER FOOTING m w c Z 0: a O (On Z � J U ., AA W U _ ' 4 fdl POST auA1 ALTERNATE (1) -1LIJ a 3' Mm. (ttp. w++ 2zirJ(' ANGLE V (4) /12+}••' S.M BRACE DRAWN BY: DYK 4' NOMINAL CONCRETE SLAB 2•. PUR1N 2'zt'aII' ANGLE (BRACE) W/ CHECKED Sr. DYK (2500 PSI. MIN. W/B.wlo 10 <4) N2.3'i' s.Ms. a EACH W.W.M. OR RD (4) 012BER BOD(SEC.0 SCALE AS SHOWN CPDLWROPnENE FIBER - DATE: enims 1.5 POUND (MIN)PER C.Y.) e n O m� q O 2aLdL' ANGLE 2' LONG ON LMOERSIDEW/(4) fl;z ' S.M.S. 4 : MAV WY FACN LEG (BEAM h BRACE) • .. .�,... ' .'. ; • 40 :.�.... BE ETA` . OR sLaPEli • 4„ •v "• • " . a11O.A" S.M.B. a FACEADO YEON KIM, P.E. EACH END) . REG. NUMBER 49497n PLAN) ED)EAC NALTERNATE 121 ,a DO KIAtt-SO ITS, LLC • 1423 BRACE UNDISTURBED SOL OR COWACE Tmp CRUSHED LIIEROO( (BOW PROCTOR) \/ ID(. (1)-15 REBAR CONTINUOUS, SPLICE yL1'li MUST OVERLAP 20' MIN. PLAN - TYPICAL ROOF F B'WNJ 3• COVER C"') BRACE TO BEAM CONNECTION 1 FOUNDATION/SLAB DETAIL Drawing No. - 060811 SHEET 20F3 FILE COPY Genera! Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318. Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318. 3. All dimensions are provided by contractor, 00 Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 7005453 Alloy, 6005-T5 Alloy; for secondary components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6. Unless otherwise noted, SMB shall be stitched with #10x3/4" SMS at 24"o.c., top and bottom. 7. Connections using screw bosses shall have minimum (4)410x2" per connection unless shown otherwise. 8. Unless otherwise shown. screws shall have minimum edoe distance and center -to -center distances as shown in this table. C-1022 Low Carbon Steel SMS & Self -Drilling ITEK) Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance #10 0.188 '/ii' V2" #14 (1/4") 0.250 Y2" DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENS INEE IRS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED J Q w 0 p c LU 0 U 0 c z w iv w O v' a F cn J W (n Il U O DYK DO YEON KIM, P.E. FLA REG. NUMBER 49497 9. Structure has been designed to meet the 6" Edition FBC (2017 FBC). Project is sited where the ultimate design wind speed, V41, is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure B. Design pressures are from Table 2002.4, o KI a �6867 2ClATrS, LLC 2017 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASO).6867 9 Ta FL 33679 10. Concrete anchors may be "Large Diameter Tapcons" (LTOs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal. 11. Screen enclosure structure shall meet Section 454.2.17 Residential Swimming Barrier Requirements and the screen enclosure per 454.2.17.1.11. if enclosing a pool. Drawing No. - 060811 SHEET 3 OF