Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEa Project Name: Project Address: /fa/ - da21 Planning& Development ServiEX e_n COP Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL34982-(772) 62-15fiECEIVED Certification for Design Load Compliance -I -JAN 0 2-1019 ST. Lucie Permit #: Occupancy Type: Construction Type: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or mufti -family) SCq o Residential Addition eye ey�/�c4 o Any accessory structure requiring a building permit 4% o Any non-residential structure. ' Note: Form not required for interior renovations provided that no exterior structural elements are affected certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 mph X ASO _LRFD End Zane Width:.6 ft S. Mean Roof Height / r7pp ft Roof Pitch: 6 :12 Parapet N/A ft 6. Components & Cladding Design P5essures Used: (PSF, based on 10sgk @@ IVMRH, dearly label on all plan openings): 5� Zone 1: —N,. Zone 2:- >5- 3 Zone 3: ^ fl/. % Zone 4: -3; •, Zone 5: --YGcS"' Garage: 3 ,r7/5 r 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: WA PSF Dock: NIA PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? Yes )!C._NotApplicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also ce that structural elements depicted on these plans provide adequate resistance to the design forces spe ' tt0: , Pawaz (J Print Name Cert # & Co. Cert Auth. s' Date, antlse I /(a 3 y Set_ ✓11�u/1� f g Company Name & Address Revised 07/2S/2014.