HomeMy WebLinkAboutENERGY EFRFICIENCY CODEORM R405-2017 FILE COPY {I,-LORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation---Residential-Performance Method F.f Project Name: MW-2056 Builder Name: GHO HOMES gV Street: 9628 KNOLLWOOD LN Permit Office: ST. LUCIE BLDG DPTMNT St L City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: O !nv �.� ucle County Owner: Jurisdiplion: V Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2107.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 1883.70 f' b. Frame - Wood, Adjacent R=11.0 224.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 10. Ceiling Types (1954.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1954.00 ft = 6. Conditioned floor area above grade (ft') 1954 b. NIA R= ft' -- Conditioned floor area below grade (ft2) 0 c. NIA R= ft' 11. Ducts R ft' 7. Windows(266.5 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 651 a:' U-Factor: Dbl, U=0.62 266.50 ft' , SHGC: SHGC=0.26 b. U-Factor: N/A ft' 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 42.0 SEER:16.00 m c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Strip Heat 24.8 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons d. Floor Types 119.14.0 sgft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 1954.00 ft' b. Conservation features b. N/A R= ft' None • c. N/A R= ft' 15. Credits Patel Glass/Floor Area: 0.136 Total Proposed Modified Loads: 60.48 PASS SS Total Baseline Loads: 64.68 r!�►�7 f hereby certi that the plans and specifications covered by Review of the plans and 4K8E STgl this calculation a in co pliance with a Florida Energy specifications covered by this 1� Cade. calculation indicates compliance with the Florida Energy Code. rnn"a ..i;'.,`.,•',,,, 'PREPARED B DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 a / I hereby certify th is b , as as s in compliance Florida Statutes. 9� COD0 with the Florida nor /Code -OWNER/AGENT: / BUILDING OFFICIAL: DATE: DATE: v -.R Compliance requires certifica Von the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in actor nee w ` envelope leakage test report with envelope leakage no greater than 5.00 ACH50 ( lr1 e m i 1/17/2019 10:46 AM JAN ° 2 _r]'9 ermitting Department EnergyGauge® USA Section R405.4.1 Compliant 419t. Pag 1 of4 Lucie County, FL an FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT R A PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: _ New/Existing: Comment: MW-2056— - - - - - - - - - - Bedrooms_ - - - -2 _ _ _ User Conditioned Area: 1954 Total Stories: 1 1 Worst Case: No GHO HOMES Rotate Angle: 0 ST. LUCIE BLDG DPTMNT Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) - - Address Type: Lot #- - Block/Subdivislon: PlatBook: Street: County: City, State, Zip: Street Address 9628 KNOLLWOOD LN St. Lucie FORT PIERCE, FL, 34951 CLIMATE ' _ / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Healing Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1954 18172.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated - 1 Main 1954 18172.2 Yes 3 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 190.3 ft 0 1954 ft' -_- 0 0 1 ROOF V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitl Deck Pitch Tested Insul. (deg) 1 Hip Concrete 2185 ft' 0 ft' Medium 0.4 N 0.9 No 0 26.6 ATTIC �. / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1954 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1954 ft' 0.1 Wood 1/17/2019 10:46 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 a hwKM K4Ut)-ZU1I IIVYU I AUIVIIVIAKT 1.P11Cl.nLl0I KCYUKI WALLS - L Adjacent - - - - - - - - - - - Space _ _Cavity _ Width Height -rn - -E - Sheathing Framing Solar Below -Omt TzWall Type P- A r•f t -in- - --Area-- Rt(alue_Eractio-r-A_bs_or__-Grader%, _ 1 N Exterior Concrete Block - Ext Insul Main 4 24 3 9 4 226.3 112 0 0 0.3 0 -2 E Exterior Concrete Block - Ext Insul Main 4 59 2 9 4 552.2112 0 0 0.3 0 -3 SE Exterior Concrete Block - Ext Insul Main 4 4 0 10 8 42.7 ft' 0 0 0.3 0 -4 S Exterior Concrete Block - Ext Insul Main 4 46 2 9 4 430.9 ft- 0 0 0.3 0 5 W Exterior Concrete Block - Ext Insul Main 4 67 8 9 4 631.6 112 0 0 0.3 0 - -.6 - Garage Frame - Wood Main 11 24 0 9 4 224.0 ft2 0 0.25 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood Main None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 8.0 ft2 0 it 0 in 0 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 36.0 ft' 0 It 0 in 0 It 0 in None None 3 e 2 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft2 0 it 0 in 0 It 0 In None None 4 e 2 Metal Double (Clear) Yes 0.62 0.26 N 43.3 ft2 0 ft 0 in 0 ft 0 in None None 5 s 4 Metal Double (Clear) Yes 0.62 0.26 N 30.0 112 0 ft 0 in 0 ft 0 in None None 6 s 4 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 0 It 0 in 0 ft 0 in None None 7 s 4 Metal Double (Clear) Yes 0.62 0.26 N 72.0 ft2 0 It 0 In 0 ft 0 In None None 8 w 5 Metal Double (Clear) Yes 0.62 0.26 N 7.5 112 0 ft 0 in 0 It 0 in None None 9 W 5 Metal Double (Clear) Yes 0.62 0.26 N 36.0 ft2 0 It 0 in 0 It 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 930.9 fP 930.9 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgIA ACH ACH 50 ''l Wholehouse Proposed ACH(50) .000295 1514.3 83.14 156.35 .224 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat( None CORI 24.82 kBtulhr 1 sys#1 Ill 7/2019 10:46 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT It r r COOLING SYSTEM i V system Type - - - - - - - -Subtype_ _ Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 42 kBtU/h-r --1260-cfm - -0:7- - - -0- - _ sys#1 _ HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / — Supply-• — Return — Air CFM 25 CFM25 # Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RLF H 1 Attic 6 651 ft' Attic 597 ft' Default Leakage Main (Default) (Default) TEMPERATURES jeat Programablre Ceiling Fans: ,ThermostarXt:,Y Heating Jan Feb Mar A Mayrr Junfr[[ ]] May rr r Oct Nov Dec Venting [((( 1111 Jan [((( 1111 Feb l l l l X MarThermostat Apr [ Jun lXl Jul [ Aug Sep Oct Nov Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 - 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main Name: Signature: Rating Compant: Date: 1/17/2019 10:46 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY- CARD_ _ ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity42.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned Floor area (sq. ft.) 6. 1954 d) Room unit(PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 c) Area 7c. 266.5 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.0 14. Heating system: Capacity 24.8 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.90 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 1) Heat recovery unit HeatRec% g) Other 10131. 11.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11 a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed bIised on installed code compliant features. Builder Address of New Home: Date: II 6I11 T City/FL Zip: FORT PIERCE, FL 34951 1/17/2019 10:46:39 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1