HomeMy WebLinkAboutENERGY EFRFICIENCY CODEORM R405-2017 FILE COPY
{I,-LORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation---Residential-Performance Method
F.f
Project Name: MW-2056
Builder Name: GHO HOMES
gV
Street: 9628 KNOLLWOOD LN
Permit Office: ST. LUCIE BLDG DPTMNT
St L
City, State, Zip: FORT PIERCE, FL,
34951
Permit Number: O !nv �.� ucle County
Owner:
Jurisdiplion: V
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (2107.7 sgft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 1883.70 f'
b. Frame - Wood, Adjacent
R=11.0 224.00 ft'
3. Number of units, if multiple family
1
c. N/A
R= ft'
4. Number of Bedrooms
2
d. N/A
R= ft'
10. Ceiling Types (1954.0 sqft.)
Insulation Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0 1954.00 ft =
6. Conditioned floor area above grade (ft')
1954
b. NIA
R= ft'
-- Conditioned floor area below grade (ft2)
0
c. NIA
R= ft'
11. Ducts
R ft'
7. Windows(266.5 sgft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Main
6 651
a:' U-Factor: Dbl, U=0.62
266.50 ft'
,
SHGC: SHGC=0.26
b. U-Factor: N/A
ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
42.0 SEER:16.00
m c. U-Factor: N/A
ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft'
a. Electric Strip Heat
24.8 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
0.000 ft.
Area Weighted Average SHGC:
0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
d. Floor Types 119.14.0 sgft.)
Insulation Area
EF: 0.900
a. Slab -On -Grade Edge Insulation
R=0.0 1954.00 ft'
b. Conservation features
b. N/A
R= ft'
None
• c. N/A
R= ft'
15. Credits
Patel
Glass/Floor Area: 0.136
Total Proposed Modified Loads: 60.48
PASS
SS
Total Baseline Loads: 64.68
r!�►�7
f hereby certi that the plans and specifications covered by
Review of the plans and
4K8E STgl
this calculation a in co pliance with
a Florida Energy
specifications covered by this
1�
Cade.
calculation indicates compliance
with the Florida Energy Code.
rnn"a ..i;'.,`.,•',,,,
'PREPARED B
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
a
/
I hereby certify th is b , as as s in compliance
Florida Statutes.
9�
COD0
with the Florida nor
/Code
-OWNER/AGENT: /
BUILDING OFFICIAL:
DATE:
DATE:
v
-.R Compliance requires certifica Von the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in actor nee w
` envelope leakage test report with envelope leakage no greater than 5.00 ACH50 ( lr1 e m i
1/17/2019 10:46 AM
JAN ° 2 _r]'9
ermitting Department
EnergyGauge® USA Section R405.4.1 Compliant 419t.
Pag 1 of4
Lucie County, FL
an
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
R
A
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
_ New/Existing:
Comment:
MW-2056— - - - - - - - - - - Bedrooms_ - - - -2 _ _ _
User Conditioned Area: 1954
Total Stories: 1
1 Worst Case: No
GHO HOMES Rotate Angle: 0
ST. LUCIE BLDG DPTMNT Cross Ventilation: No
Whole House Fan: No
Single-family
New (From Plans)
- -
Address Type:
Lot #- -
Block/Subdivislon:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
9628 KNOLLWOOD LN
St. Lucie
FORT PIERCE,
FL, 34951
CLIMATE
' _ /
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Healing Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1954 18172.2
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfI ID Finished Cooled Heated
- 1
Main
1954 18172.2 Yes 3
2
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 190.3 ft 0
1954 ft'
-_-
0 0 1
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitl Deck Pitch
Tested Insul. (deg)
1
Hip
Concrete 2185 ft' 0 ft' Medium
0.4
N 0.9
No 0 26.6
ATTIC
�. /
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1954 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1954 ft' 0.1
Wood
1/17/2019 10:46 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4
a
hwKM K4Ut)-ZU1I IIVYU I AUIVIIVIAKT 1.P11Cl.nLl0I KCYUKI
WALLS
- L
Adjacent - - - - - - - - - - -
Space
_ _Cavity _ Width Height
-rn -
-E -
Sheathing Framing Solar
Below
-Omt
TzWall Type P- A r•f t
-in- -
--Area--
Rt(alue_Eractio-r-A_bs_or__-Grader%,
_ 1 N
Exterior Concrete Block - Ext Insul Main
4 24 3 9
4
226.3 112
0
0 0.3
0
-2 E
Exterior Concrete Block - Ext Insul Main
4 59 2 9
4
552.2112
0
0 0.3
0
-3 SE
Exterior Concrete Block - Ext Insul Main
4 4 0 10
8
42.7 ft'
0
0 0.3
0
-4 S
Exterior Concrete Block - Ext Insul Main
4 46 2 9
4
430.9 ft-
0
0 0.3
0
5 W
Exterior Concrete Block - Ext Insul Main
4 67 8 9
4
631.6 112
0
0 0.3
0
- -.6 -
Garage Frame - Wood Main
11 24 0 9
4
224.0 ft2
0
0.25 0.3
0
DOORS
#
Omt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N Wood Main
None
.39
3
8
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
n 1 Metal Double (Clear) Yes
0.62 0.26 N
8.0 ft2
0 it 0 in
0 ft 0 in
None
None
2
n 1 Metal Double (Clear) Yes
0.62 0.26 N
36.0 ft'
0 It 0 in
0 It 0 in
None
None
3
e 2 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft2
0 it 0 in
0 It 0 In
None
None
4
e 2 Metal Double (Clear) Yes
0.62 0.26 N
43.3 ft2
0 ft 0 in
0 ft 0 in
None
None
5
s 4 Metal Double (Clear) Yes
0.62 0.26 N
30.0 112
0 ft 0 in
0 ft 0 in
None
None
6
s 4 Metal Double (Clear) Yes
0.62 0.26 N
21.7 ft2
0 It 0 in
0 ft 0 in
None
None
7
s 4 Metal Double (Clear) Yes
0.62 0.26 N
72.0 ft2
0 It 0 In
0 ft 0 In
None
None
8
w 5 Metal Double (Clear) Yes
0.62 0.26 N
7.5 112
0 ft 0 in
0 It 0 in
None
None
9
W 5 Metal Double (Clear) Yes
0.62 0.26 N
36.0 ft2
0 It 0 in
0 It 0 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
930.9 fP 930.9 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgIA
ACH
ACH 50
''l Wholehouse Proposed ACH(50) .000295
1514.3 83.14 156.35
.224
5
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat( None
CORI
24.82 kBtulhr
1
sys#1
Ill 7/2019 10:46 AM
EnergyGauge® USA Section R405.4.1 Compliant Software
Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
It
r
r
COOLING SYSTEM
i V system Type -
- - - - - -
-Subtype_
_ Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 16
42 kBtU/h-r --1260-cfm -
-0:7- -
- -0- -
_ sys#1 _
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.9 50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft'
DUCTS
/ — Supply-•
— Return —
Air
CFM 25 CFM25
# Location R-Value Area
Location
Area Leakage Type
Handier
TOT OUT
ON
RLF
H
1 Attic
6 651 ft'
Attic
597 ft' Default Leakage
Main
(Default) (Default)
TEMPERATURES
jeat
Programablre
Ceiling Fans:
,ThermostarXt:,Y
Heating Jan Feb
Mar
A
Mayrr Junfr[[ ]]
May
rr
r
Oct
Nov
Dec
Venting [((( 1111 Jan [((( 1111 Feb
l l l l
X MarThermostat
Apr
[ Jun lXl Jul
[ Aug
Sep
Oct
Nov
Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11Cooling
(WD) AM
78
78
78
78 78 78
78
78 80
80
- 80
PM
80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78 78
78
78
78
PM
78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft'
0 ft
0.3
Main
Name: Signature:
Rating Compant:
Date:
1/17/2019 10:46 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY- CARD_ _
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 2 13. Cooling system: Capacity42.0
a) Split system SEER 16.0
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned Floor area (sq. ft.) 6. 1954 d) Room unit(PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.620
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260
c) Area 7c. 266.5
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.0
14. Heating system: Capacity 24.8
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.90
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
1) Heat recovery unit HeatRec%
g) Other
10131. 11.0
10B2.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11 a. 30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed bIised on installed code compliant features.
Builder
Address of New Home:
Date: II 6I11
T
City/FL Zip: FORT PIERCE, FL 34951
1/17/2019 10:46:39 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1