Loading...
HomeMy WebLinkAboutPLAN REVIEW RECORD1901-0021 V CqN -- - --St, tUciS C u® - - - PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING THE SQUARE FOOT INFORMATIOSEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION. THE ENERGY CALULATIONS MUST HAVE THE PREPARERS ORIGINAL SIGNATURE PLEASE FURNISH NEW ENERGY CALULATIONS WITH ORIGINAL SIGNATURES PER 107.1 OF THE 2017 FLORIDA BUILDING CODE ENERGY CALCS INFORMATION BLOCK AT THE TOP OF THE PAGE IS INCOMEPLETE BUILDERS NAME PERMIT OFFICE ARE MISSING. SEE SECTION 405.4.2 (1) OF THE 2017 FLORIDA ENERGY CODE. 2�1%5—INTERNATIONAL RESIDENTIAL CODE® Plan -Review-# 1901-0021 " Date:1/16/19 ' FOR ONE- AND TWO-FAMILY DWELLINGS Valuation: $328,440.00 © PLAN REVIEW RECORD Fee: $2361.56/ $17,146.56 JURISDICTION: FORT PIERCE, FL 34951 - (City, County, Township, eto.) —` — - ---- ---9628-KNOLLWOOD LN BUILDING -LOCATION: — - - (Street address)- , - BUILDING DESCRIPTION: SFR REVIEWED BY: Numerals Indicated in parenthesis are applicable code sections of the gal s Intemational Resideirdal Code (IRC). The plan reviewaccomplished as indicated in this record is limited to those code sections specifically identified herein. This recored references commonly applicable code sections with due regard for, the amount and type of detailed Information which is typically"found on construction documents for one- and two-famlly dwellings and townhouses. It fides not reference all code provisions which maybe applicable to specific buildings. This record is designedtobe used only by those who ate knowledgeable �• -and: capable of exercising.competent judgment In evaluating construction documents for code compliance. CORRECTIONS LIST No. DESCRIPTION Code Section 2015, International• prohibited. ISBN 978-1-6a983-611-8 • •• is registered To the U.S. Patent and \\TrademarkOffice, For additional forms, contact� III IIII IIIIIII I I III IIIIII •EEE•ninLINTERNATIONAL CODE• 9 781t509 836115 CODE COUNCIL'PHONE•- , t • - -1- CORRECTION LIST (cont'd.) No. DESCRIPTION Code Section -2- NOTE: Entries to this Plan Review Record that require a field check or Inspection of the Installation must be coordinated with the inspection phase (R109) of the project. BUILDING PLANNING (Chapter 3) DESIGN CRITERIA [fable R301.2(1)] Parapets and construction Floor live load (Table R301.5) psf (R302.2.2, R302.2.3) Roof live load (Table R301.6) 30 psf Two-family dwelling separation (R302.3) Ground snow load psf Dwelling unit penetrations (R302.4) Ultimate design wind speed 160 mph Dwelling/garage opening/penetration protec- tion (R302.5) Wind exposure category (R301.2.1.4) 2-C Dwelling/garage fire separation_(R302.6) High wind design criteria applicable (R301.2.1.1) Seismic design category (SDC) [Figure R301.2(2)] SDC C&D provisions (R301.2.2) Weathering NEG Frost line Termite a VH Decay area Winter design temperature Ice barrier underlayment required Flood hazards FIRE-RESISTANT CONSTRUCTION (R302) Exterior walls (R302.1, Tables R302.1(1) and R302.1(2)] Townhouse separation (R302.2) Continuity and structural independence (R302.2.1, R302.2.4) ROOM PLANNING REQUIREMENTS (R303 through R305) Under -stair protection (R302.7) Wall and ceiling finishes (R302.9) Flame spread index (R302.9.1) Smoke -developed index (R302.9.2) Testing (R302.9.3, R302.9.4) Insulation (R302.10) Flame spread/smoke-developed (R302.10.1, R302.10.2) Cellulose loose -fill and exposed attic insulation (R302.10.3, R302.10.4) Testing (R302.10.5) Fireblocking (R302.11) Draftstopping (R302.12) Fire protection of floors (R302.13) Combustible insulation clearance (R302.14) Use Area (ft2) Width Ceiling height' Natural light' Natural ventilation' Living 70 T-0" T-0" 8% floor area 4% floor area Dining 70 7'-0" T-0" 8% floor area 4% floor area Kitchen N.A. N.A. 7'-0" 8% floor area 4% floor area Bedroom 70 7'.0" 7'-0" 8% floor area 4% floor area Bathroom N.A. N.A 6'-8" 3 square feet 1 V. square feet See Sections R303.1 & R303.3 for mechanical ventilation and artificial light and R303.4 for required whole -house mechanical ventilation. t 6'-8" min. at plumbing fixtures and for non -habitable basements. X Required heating (R303.9) GLAZING (R308) SANITATION (R306 and R307) Identification (R308.1) X Water closet Louvered windows or jalousies (R308.2) X Lavatory X Tub or shower X Kitchen area with sink X Sanitary sewer (Chapter 30) X Private disposal (Appendix)) Human impact loads/hazardous locations (R308.3, R308.4) Skylights and sloped glazing (R308.6) -3- BUILDING PLANNING (cont'd.) GARAGES AND CARPORTS (R309) X Floor surface noncombustible; sloped floor (R309.1) Carport: open two sides; noncombustible floors; sloped floor (R309.2) Automatic garage door opener (R309.4) Fire sprinklers (R309.5) EMERGENCY ESCAPE AND RESCUE OPENINGS (R310) Where required (R310.1) Areas, height, width, operations (17310) Window wells (R310.2.3) Under decks and porches (R310.2.4) Bars, grilles, covers and screens (R310.4) MEANS OF EGRESS (R311) X General (17311.1) X Egress door (R311.2) Landings at exterior doors (11311.3 - R311.3.3) Vertical egress (R311.4) Construction and attachment (17311.5) X Hallways (R311.6) Stairway width, headroom, vertical rise, walk - line (R311.71 - R311.7.4) Stairway treads, risers profiles (17311.75 - R311.7.5.4) Stairway landings and walking surfaces (R311.76, R311.7.7) Handrails required (17311.7.8) Handrail height, continuity, grip -size (17311.7.8.1 - R311.7.8.4) Stairway illumination (13303.7, R311.79) Special stairways (17311.710) Ramp slope, landings, handrails (R311.8) GUARDS AND WINDOW PROTECTION (R312) Required for open -sided surfaces, stairs, ramps and landings > 30" above floor/ grade (13312.1.1) Height -36" (R312.1.2) Opening limitations (R312.1.3) Window fall protection (R312.2) AUTOMATIC FIRE SPRINKLER SYSTEMS (R313) Townhouses (R313.1) One- and two-family dwellings (R313.2) SMOKE ALARMS (R314) Referenced standards (R314.1) Location and interconnection (R314.3, R314.4) Power source (R314.6) CARBON MONOXIDE ALARMS (R315) New construction (17315.1, 13315.2) Existing construction (R315.2.2) Referenced standard (13315.6) FOAM PLASTIC (R302.8, R316) Labeling (R316.2) Surface burning, thermal barrier, specific approval (R316.3 - R316.8) DECAY AND TERMITE PROTECTION (R317 and R318) X Protection required (Table R301.2(1), R3171, R318.1) Quality mark (R317.2 and R318.1.1) SITE ADDRESS (R319) Address numbers (13319.1) ACCESSIBILITY (R320) Type B dwelling units applicable (13320.1) ELEVATORS/PLATFORM LIFTS (R321) Referenced standards (17321.1 - R321.3) FLOOD -RESISTANT CONSTRUCTION (R322) General (R322.1) Hazard area and requirements (R301.2.4, R309.3, R322.2, R322.3) Design professional (R322.3.6) STORM SHELTERS (R323) Generallreferenced standard (R323.1) SOLAR ENERGY SYSTEMS (R324) System, installation, access (R324.2 - R324.7) MEZZANINES (R325) Area, egress, openness (R325.2 - R325.5) SWIMMING POOLS, SPAS AND HOT TUBS (R326) ISPSC (13326.1) .4- FOUNDATIONS (Chapter 4) Wood foundations (13402.1) Concrete, compressive strength (R402.2, R402.3) FOOTINGS (R403) X -_ Soil bearing value (13401.4, R403.1) X Footing width (Tables R403.1(1) - R403.1(3)] Footing edge thickness; footing projection = 2" minimum, buts footing thickness (R403.1.1) Footings in SDC and D (R403.1.2 and R403.1.6.1) X Depth below (outside) grade = 12" minimum; but below frost line (13403.1.4, R403.1.4.1) Sill plate bolting in concrete/masonry ='/2" di- ameter bolts, within 12" but not less than 7 bolt diameters from ends, 7" embedment (R403.1.6) Footings adjacent to slopes (R403.1.7) Frost -protected shallow foundations (R403.3) Footings for precast concrete foundations (R403.4) FOUNDATION/RETAINING WALLS (R404 - R406) Masonry foundation walls (R404.1.2) Wall height, unbalanced backfill, nominal thickness (Tables R404.1.1(1) - R404.1.1(4), R404.1.5.1] Reinforcement size and spacing (Tables R404.1.1(2) - R404.1.1(4)] Concrete foundation walls (R404.1.3) Wall height, unbalanced backfill, nominal thickness (Tables R404.1.2(1) - R404.1.2(8), R404.1.5.21 Horizontal and vertical reinforcement size and R404.1.3.2, Stay -in -place forms (R404.1.3.3.6.1) SDC D provisions (R404.1.4) Height above finished grade (R404.1.6) Sill plate size (R404.3) Precast concrete foundation walls (R404.5) Drains required if habitable or usable spaces are below grade` (R405) Soil class (Table R405.1) Dampproofing if basements are below grade' (R406.1) Waterproofing if high water table' (R406.2) ' If uninhabitable, see Under -Floor Space (13408) COLUMNS (R407) Protection from decay or corrosion (R407.1 and R407.2) X Structural requirements (R407.3) Anchorage (R407.3) Wood columns (minimum 4" square) (R407.3) Steel columns (minimum 3" diameter, Sched- ule 40 pipe) (R407.3) UNDER -FLOOR SPACE (R408) Ventilation (R408.1 and R408.2) Unvented crawl space (R408.3) Access (R408.4) Removal of debris (R408.5) Finished grade (R408.6) Flood resistance (R408.7) -5- FLOORS (Chapter 5) WOOD JOISTS AND GIRDERS (R502) Species and grade (17502.1) Joists —Sleeping areas, LL = 30 psf [Table R502.3.1(1)] Joists—Nonsleeping areas, LL = 40 psf [Table R502.3.1(2)] Cantilevered joists (Tables R502.3.3(1) and R502.3.3(2)] Girder and header spans (Tables R602.7(1) - R602.7(3)] Joists under bearing partitions (R502.4) Bearing (1.5" minimum on wood or metal; 3" on masonry or concrete) and lapped joists (311) (R502.6, R502.6.1) Lateral restraint and bridging (13502.7, R502.7.1) Drilling and notching (R502.8) Fastening (R502.9) Framing of openings (R502.10) Wood trusses (R502.11) Draftstopping (13502.12) LUMBER FLOOR SHEATHING (R503.1) Allowable span (Table R503.1) End joints (13503.1.1) WOOD STRUCTURAL PANEL SHEATHING (R503.2) Grade (R503.2.1) Thickness (R503.2.1) Allowable spans (Tables R503.2.1.1(1) and R503.2.1.1(2)] Installation [Table 602.3(1)] PARTICLEBOARD UNDERLAYMENT (R503.3) Grade (17503.3.1) Thickness (R503.3.2) Installation [Table R602.3(1)] TREATED -WOOD FLOORS (ON GROUND) (R504) Base course: 4" thick with maximum 3/4' gravel or'/2' crushed stone (R504.2.1) Moisture barrier: placed over base course (R504.2.2) Materials (R504.3) STEEL FLOOR FRAMING (R505) Cold -formed steel; applicability limits; in -line framing (R505.1) Structural framing (R505.2) Material (17505.2.1) Corrosion protection (R505.2.2) Identification (R505.2.4) Fastening (R505.2.5) Floor construction (R505.3) CONCRETE FLOORS (ON GROUND) (R506) X Thickness: 31/z" minimum; Concrete strength (R506.1) Support: prepared subgrade; maximum earth fill = 8"; maximum sand or gravel fill = 24" (R506.2.1) Base course: 4" graded with 2" maximum aggregate (17506.2.2) X Vapor retarder (R506.2.3) X Reinforcement support (R506.2.4) EXTERIOR DECKS (R507) Support, attachment (R507.1 - R507.2.4) Plastic composite materials (R5073) Decking/deckjoists (R507.4, R507.5) Deck beams (R507.6) Deck posts, connections, footings (R507.7.1, R507.8) 19 WALL CONSTRUCTION (Chapter 6) Construction (Figures R602.3(1) and R602.3(2)] Stud grade (R602.2) Design/construction (R602.3) Studspacing[R602.3.1, Table R602.3(5)] Interior load -bearing walls (R602.4) X Interior nonbearing walls: 2" x 3" at 24" o.c. or 2" x 4" flat at 16" o.c. (R602.5) Drilling and notching —studs (17602.6) Drilling and notching —top plate (R602.6.1) Headers (Tables R602.7(1) - R602.7(3) and Figure R602.7.21 Fireblocking (R602.8, R302.11) Cripple walls (17602.9) Wall bracing, lines, panels (R602.10.1, R602.10.2) Required length of bracing, method (R602.10.3, R602.10.4, Tables R602.10.3(1) and R602.10.3(3)] Minimum length, connections, support, joints, cripple walls (17602.10.5-14602. 10. 11) Wall anchorage (SDC C and D) (17602.11) Simplified wall bracing (13602.12) STEEL WALL FRAMING (R603) General (R603.1) Structural framing (R603.2) Material (R603.2.1) Corrosion protection (R603.2.2) Identification (R603.2.4) Fastening (R603.2.5) Wall construction (R603.3 - R603.5) Headers (17603.6) Studs, tracks and structural sheathing (R603.7 - R603.9) SHEATHING (R604 and R605) Wood structural panels (R604) Particleboard (R605) MASONRY CONSTRUCTION (R606 - R610) X General design (R606) Seismic requirements (R606.12) Glass unit masonry (R607) X Exterior concrete wall construction (17608) X Exterior windows/doors (R609) Glass unit masonry (17610) STRUCTURAL INSULATED PANEL WALL CONSTRUCTION (R610) Applicability (R610.2) Materials (R610.3) Wall panels, construction details (R610.4 - R610.10) -7- WALL COVERING (Chapter 7) INTERIOR WALL COVERING (R702) Plaster material (R702.2) Plaster support (R702.2.3) X Gypsum board materials (R702.3.1) Gypsum board support, application and fas- tening (R702.3.2 - R702.3.7) X Ceramic tile (R702.4) Other finishes (R702.5 and R702.6) Vapor retarders (R702.7) EXTERIOR WALL COVERING (R703) X Water -resistive barrier (R703.2) Attachment and minimum thickness [Table R703.3(1)] Wood siding (R703.5) Wood shakes and shingles (R703.6) Exterior plaster (R703.7) _Stone & masonry veneer (R703.8 & Figure R703.8); Steel angle lintels-4" minimum bearing each end (R703.8.3) Veneer ties: #9 U.S. gage wire or #22 U.S. gage by'/8" corrugated metal; horizontal and vertical spacing _2.67_square feet maximum area supported (wind > 30 psf and SDC C or D, maximum area = 2 square feet) (R703.8.4.1) Flashing (R703.4 and R703.8.5) Exterior insulation and finish systems (R703.9) X Fiber cement siding (R703.10) Vinyl siding (R703.11) Other sidings (17703.12 - R703.17) ROOF -CEILING CONSTRUCTION (Chapter 8) WOOD ROOF FRAMING (R802) Fire -retardant -treated wood (R802.1.5) X Framing details (R802.3) Rafter ties (R802.3.1) Collar ties (4' o.c., in upper third of attic) (R802.3.1) Purlins (2" x 4" at 4' o.c. minimum) (Figure R802.5.1, R802.5.1) Bearing (R802.6) Cutting and notching (R802.7) X Engineered wood products (R802.72) Lateral support and bridging (R802.8) X Framing of openings (13802.9) X Wood trusses (13802.10) X Roof tie -down (13802.11) CEILING JOISTS [Tables R802.4(1), R802.4(2)] Without attic storage, LL = 10psf With attic storage LL = 20psf Spacing Species and grade X Span X Size RAFTERS [Tables R802.5.1(1) - R802.5.1(8)] Ground snow load/LL = 20 psf Controlling design (LL or snow) Ceiling not attached/ceiling attached Spacing Species and grade Span Size Hc/HR; Adjustment factor ROOF SHEATHING (R803.2) Grade X Thickness FRTW allowable stresses/grading X Allowable spans [Table R503.2.1.1(1)] X Installation (R803.2.3) ROOF -CEILING CONSTRUCTION (cont'd.) General (R804.1) Structural framing (R804.2) Material (R804.2.1) Corrosion protection (R804.2.2) Identification (R804.2.3) Fastening (R804.2.5) Roof construction (R804.3) Roof tie -down ROOF VENTILATION (R806) X Ventilation requirements (R806.1 - R806.5) ATTIC ACCESS (R807) X Access requirements (807.1) ROOF ASSEMBLIES (Chapter 9) ROOF CLASSIFICATION (R902) X Roof covering materials (R902.1) WEATHER PROTECTION (R903) Flashing (R903.2) Coping (R903.3) Roof drainage (R903.4) MATERIALS (R904) Compatibility; specifications; physical charac- teristics; identification (17904.2 - R904.4) REQUIREMENTS FOR ROOF COVERINGS (R905) X Underlayment (R905.1.1, R905.1.2) Asphalt shingles (R905.2) Clay and concrete tile (R905.3) Metal roof shingles (17905.4) Mineral -surfaced roll roofing (R905.5) Slate shingles (R905.6) Wood shingles (R905.7) Wood shakes (R905.8) Built-up roofs (R905.9) X Metal roof panels (R905.10) NOA / PA Modified bitumen roofing (R905.11) NOA / PA Thermoset single -ply roofing (R905.12) NOA / PA Thermoplastic single -ply roofing (17905.13) NOA / PA Sprayed polyurethane foam roofing (R905.14) NOA / PA Liquid -applied roofing (R905.15) NOA / PA Photovoltaic shingles (R905.16) ROOF INSULATION (R906) General (17906.1) ROOFTOP - MOUNTED PHOTOVOLTAIC SYSTEMS (R907) Materials and installation (R9071 - R907.5) REROOFING (R908) Materials and methods (R908.1) Structural support (R908.2) Replacement/re-covering (R908.3, R908.4) ROOFTOP - MOUNTED PHOTOVOLTAIC PANEL SYSTEMS (R909) Materials and installation (17909.1 - R909.3) CHIMNEYS AND FIREPLACES (Chapter 10) MASONRY FIREPLACES (R1001) Construction (Figure R1001.1 and Table R1001.1) SDC D reinforcing/anchorage (R1001.3 and R1001.4) Firebox walls and dimensions (R1001.5 and R1001.6) Steel fireplace units (R1001.5.1) Lintel (noncombustible) (R1001.7) Hearth extension (171001.9, R1001.10) Fireplace clearance (111001.11) Fireblocking (R1001.12) MASONRY CHIMNEYS (R1003) Construction (Table R1001.1, R1003.2, R1003.3, and Figure R1001.1) Corbeling (R1003.5) CHIMNEYS AND FIREPLACES (cont'd.) Changes in dimension (R1003.6) Additional load (R1003.8) Termination (171003.9) Spark arrestors (R1003.9.2) Wall thickness; z 4" (131003.10) Flue lining - material/installation (131003.11 and R1003.12) Multiple flues (131003.13) Flue area (appliance) (171003.14) Flue area (masonry fireplace) (171003.15) Inlet (171003.16) Cleahout opening (R1003.17) Chimney clearance (R1003.18) Fireblocking (R1003.19) Chimney crickets (R1003.20) FACTORY -BUILT FIREPLACES (111004) Listed and labeled (171004.1) Installation (R1004.2 - R1004.5) FACTORY -BUILT CHIMNEYS (R1005) Listed and labeled (R1005.1) Installation (R1005.3and R1005.4) EXTERIOR AIR SUPPLY (1711006) Intake size (131006.2, R1006.4) ENERGY EFFICIENCY (Chapter 11) Compliance; information Electrical (N1104) (N1 f01.5, N1101.13) Simulated performance (N1105) Climate zone (Table N1101.7) ERI compliance alternative (N1106) Building thermal envelope (N1102) Existing buildings (N1107 - N1111) Systems (N1103) MECHANICAL (Chapters 12-23) Appliance labeling (M1302, M1303) Appliance access (M1305, M1401) Appliance installation (141307) Heating and cooling equipment; load calcula- tions (Chapter 14) Exhaust systems (Chapter 15) Duct systems (Chapter 16) Combustion air (Chapter 17) Chimney and vent location and terminations (Chapters 10 and 18) Special equipment (Chapter 19) Boilers/water heaters (Chapter20) Hydronic piping (Chapter2l) Special piping and storage systems (Chapter22) Solar thermal energy systems (Chapter23) Penetrations of fire -resistance rated assem- blies (R302.4, R302.5) FUEL GAS (Chapter 24) Application (G2401.1) Clearances (G2409) General regulations (G2404) Electrical and electrical bonding (G2410, G2411) Appliance location (G2406) Pipe sizing (G2413) Air requirements (G2407) Piping materials (G2414) Installation (G2408) -10- FUEL GAS (cont'd) Piping installation (G2415 and G2419) Piping support (G2418 and G2424) Valves, controls, connections (G2420, G2421 and G2422) Venting (G2425 - G2429) -Mist appliances - (G2423, G2430 - G2454) PLUMBING (Chapters 25-33) Water service location and depth (172603, P2604) Sanitary and storm sewer location and depth (P2603, P2604) Piping support (Table P2605.1) Listed plastic materials (P2609) Plumbing fixtures (Chapter27) Water heater size and location (Chapter28) Water supply and distribution system -design and calculations (Chapter29) Dwelling unit fire sprinkler systems (P2904) NFPA 13D system (P2904.1) Temperature rating (P29042.1, P290422) Freezing protection (P2904.2.3) Sprinkler coverage (P2904.2.4) Piping materials (P2904.3) Flow rates (P2904.4.1, P2904.42) Water supply capacity (P2904.52) Pipe sizing (P2904.6) Drain, waste and vent pipe sizing and riser diagram (P3004, P3005, Chapter3l) Sumps and ejectors (P3007) Backwater valves (P3008) Fixture traps (P3201) Storm drainage (Chapter33) Penetrations of fire -resistance rated assem- blies (R302.4, R302.5) ELECTRICAL (Chapters 34-43) Penetrations of fire -resistance rated assem- Wiring methods (Chapter38) blies (E34022) Required lighting and receptacle outlets Listed and labeled materials (E3403) (E3901, E3903) Service equipment and location (E3405, E3601, E3606) Service size and load calculations (E3602) Available fault current (E3606) System grounding (E3607) Required branch circuits (E3703) Feeder requirements and load calculations (E3704) Ground -fault and arc -fault circuit -interrupter protection (E3902) Devices and lighting fixtures (Chapter40) Appliance installation (Chapter 41) Swimming pools (Chapter42) Class 2 remote -control, signaling and power - limited circuits (Chapter43) MANUFACTURED HOUSING USED AS DWELLINGS (Appendix E) Provisions adopted (R102.5) Compliance with Appendix E verified SEE PASSIVE RADON GAS CONTROLS (Appendix F) Provisions adopted (R102.5) Compliance with Appendix F verified PATIO COVERS (Appendix H) Provisions adopted (R102.5) Compliance with Appendix H verified PRIVATE SEWAGE DISPOSAL (Appendix 1) Provisions adopted (R102.5) Compliance with Appendix I verified EXISTING BUILDINGS AND STRUCTURES (Appendix J) Provisions adopted (R102.5) Compliance with Appendix J verified SOUND TRANSMISSION (Appendix K) Provisions adopted (R102.5) Compliance with Appendix K verified HOME DAY CARE—R-3 OCCUPANCY (Appendix M) Provisions adopted (R102.5) Compliance with Appendix M verified AUTOMATIC VEHICULAR GATES (Appendix O) Provisions adopted (R102.5) Compliance with Appendix O verified SOLAR -READY PROVISIONS (Appendix U) Provisions adopted (R102.5) Compliance with Appendix U verified NOTES -12-