HomeMy WebLinkAboutENERGY EFFICIENCY CODE - FILE COPYFORM R405-2017
Zoi - oar
FILE COPY
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business anctProfessional-Regulation-Residential-PP-erforrnance-Method
Project Name: MW-68
Builder Name:
RECEIVED
Street: 2632 CONIFER DR
Permit Office:
City; State, Zip: FORT PIERCE, FL, 34951
Permit Number.
JAN 0 2 2019
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (FI rATIPMEW68no
2
)Permittinu
unty,
1. New construction or existing New (From Plans)
9. Wall Types (1830.1 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.0 1632.60 ft2
b. Frame - Wood, Adjacent
R=11.0 197.56 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. WA
R= ft
5. Is this a worst case? No
10. Ceiling Types (1832.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1832.00 ft=
6. Conditioned floor area above grade (ft2) 1832
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(263.7 sqft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Mal 6 629
�CgNNED
a. U-Factor: Dbl, U=0.62 263.67 ft2
SHGC: SHGC=0.26
12. Cooling
BYkBtulhr
b. U-FactoNIA ft2
systems
`St
Efficiencyr.
SHGC:
a. Central Unit Lucie
C 36.0 SEER:16.00
olint
c. U-Factor: NIA ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. NIA ft2
a. Electric Strip Heat
24.8 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
8. Floor Types (1832.0 sgft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1832.00 ft2
b. Conservation features
EF: 0.900
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Patel
Glass/Floor Area: 0.144 Total Proposed Modified Loads: 57.55
PASS
Total Baseline
Loads: 61.28
1 hereby certify that the plans and specifications covered by
Review of the plans and
ST't?E.
this calculation are in compliance with the Florida Energy
specifications covered by this
�F4HE
= O�
Code. ^ v�
*V4---
calculation indicates compliance
the Florida Energy Code.
q iii, =;Z-' A
(• •.; >,,.•
with
nu,. n „ O
PREPARED BY:
Before construction is completed
r O
DATE; 11/8/18
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
.�
with the Florida Eneer/r@y��C''ottde.nn�� nn--..,,'' ��II
OOp WE
OWNER/AGENT 4AA:t� UCb-UAL
BUILDING OFFICIAL:
DATE: 11
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
11/8/2018 11:20 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
— Title:— — —
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
" Jurisdiction:
Family Type:
New/Existing:
— Comment:
—MW-68- — — —
User
1
Single-family
New (From Plans)
— — —_—_.Bedrooms:— _ 2 _
Conditioned Area: 1832
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type:
Lot -#--
Block/Subdivision:
PlalBook:
Street:
County:
City, State, Zip:
Street Address
2632 CONIFER DR
St. Lucie
FORT PIERCE,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockt
1832 17037.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled Heated
1
Main
1832 17037.6 Yes 3
2
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 166.5 ft 0
1832 ft-
----
0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Concrete 2049 ft' 0 ft' Medium
0.4
N 0.9
No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150
1832 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Double Batt 1832 ft' 0.1
Wood
11/8/2018 11:20 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
--
rnt
Adjacent - Cavity Width Height
In WaLLSype -Space-R-glueEraction--Absoc--Grade/_
Sheathing Framing Solar Below
_ 1 N
Exterior Concrete Block - Ext Insul Main
4 43 7 9
4
406.8 ft2
0
0 0.3
0
-2 E
Exterior Concrete Block - Ext Insul Main
4 53 10 9
4
502.4 ft2
0
0 0.3
0
-3 S
Exterior Concrete Block - Ext Insul Main
4 19 6 9
4
182.0 ft'
0
0 0.3
0
._4 W
Exterior Concrete Block - Ext Insul Main
4 58 0 9
4
541.3 ft'
0
0 0.3
0
5 -
Garage Frame - Wood Main
11 21 2 9
4
197.6 ft2
0
0.25 0.3
0
-
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S Wood Main
None
.39
3
8
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
_ /
Wall
Overhang
V #
Omt 10 Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
n 1 Metal Double (Clear) Yes
0.62 0.26 N
30.0 ft2
0 It 0 in
0 It 0 in
None
None
_ 2
n 1 Metal Double (Clear) Yes
0.62 0.26 N
36.0 ft2
0 ft 0 in
0 It 0 in
None
None
3
n 1 Metal Double (Clear) Yes
0.62 0.26 N
96.0 ft-
0 It 0 in
0 ft 0 in
None
None
4
e 2 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft-
0 It 0 in
0 ft 01n
None
None
5
e 2 Metal Double (Clear) Yes
0.62 0.26 N
7.0 ft2
0 ft 0 in
0 ft 0 in
None
None
_ 6
e 2 Metal Double (Clear) Yes
0.62 0.26 N
21.7 ft2
0 ft 0 in
0 It 0 in
None
None
_ 7
s 3 Metal Double (Clear) Yes
0.62 0.26 N
26.0 ft2
0 ft 0 in
0 ft 0 in
None
None
8
w 4 Metal Double (Clear) Yes
0.62 0.26 N
20.0 ft-
0 It 0 in
0 It 0 in
None
None
9
W 4 Metal Double (Clear) Yes
0.62 0.26 N
15.0 ft2
0 ft 0 in
0 It 0In
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
584 ft2 584 ft2
64 ft
8
It
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000295
1419.8 77.95 146.59
.224
5
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1
24.82 kBtu/hr
1
sys#1
11/8/2018 11:20 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
_# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 16
36 kBtu/h-r----T089-cfm—0.7--I-
—sys#1---
HOT WATER SYSTEM
# System Type
SubTpe
Location
EF Cap
Use
SetPnl
Conservation
1 Electric
None
Garage
0.9 50 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Carl # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft'
DUCTS
_ / —Supply—
Return
Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1 Attic
6 629 ft'
Attic
515 ft' Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programabire,Thermostat:
CFans:
]]Y
Heatng Jan [X] Feb
[[ ��
[X] Mar
Aprrreiling
Apr
[[XX]]
Jay un I I Jul
fXI
[ ] Aug
rX�
[ ] Sep
�
rD0'
Dec
rD0'
Ventl I 1 Jan l 1 Feb
l l
lX) Mar
[
May l l Jun I) Jul
I ] Aug
[ ] Sep
Oct
[X] Nov
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Healing(WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft'
Oft
0.3
Main
Name:
Rating Compant:
Signature:
Date:
11/8/2018 11:20 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL-)-DISPLAY CARD-- -
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1.
New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts
R 6.0
2. Single-family or multiple -family
2.
Single-family
b) Return ducts
R 6.0
c) AHU location
Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system:
Capacity36.0
a) Split system
SEER 16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package
SEER
c) Ground/water source
SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1832
d) Room unit/PTAC
EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.620
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260
c) Area 7c. 263.7
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.0
14. Heating system: Capacity24.8
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.90
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
1081. 11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied Pith the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installs (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed basecfQn installed code compliant features.
Builder
Address of New Home:
Date:
City/FL Zip: FORT PIERCE, FL 34951
11/8/2018 11:20:28 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1
-- wrightsoft. Load Short Form
Entire House
For: MW-68
2632 CONIFER DR, FORT PIERCE, FL 34951
Job:
Date: Nov 6, 2018
By:
Design Information
Htg
Clg Infiltration
Outside db (°F)
43
91 Method Simplified
Inside db (°F)
70
72 Construction quality Average
Design TD (°F)
27
19 Fireplaces 0
Daily range
-
L
Inside humidity (°/a)
30
50
Moisture difference (gr/lb)
0
65
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
7.3
kW
24817
Btuh
19
°F
1167
cfm
0.047
cfm/Btuh
0
in H2O
COOLING EQUIPMENT
Make
Carrier
Trade
16 SEER PURON AC
Cond
CA16NA036""A
Coil
FV4CNB006
AHRI ref
4584643
Efficiency
13.7 EER, 16.5 SEER
Sensible cooling
24500 Btuh
Latent cooling
10500 Btuh
Total cooling
35000 Btuh
Actual air flow
1167 cfm
Air flow factor
0.050 cfm/Btuh
Static pressure
0 in H2O
Load sensible heat ratio 0.66
ROOM NAME
Area
W)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
MASTER SUITE
312
5079
3663
239
181
HER WIC
60
941
432
44
21
MASTER BATH
169
1815
1830
85
91
BED 2
205
2427
2881
114
143
UTILITY
72
599
920
28
46
BATH 2
79
78
218
4
11
FOYER
100
792
608
37
30
DINING
130
3727
3552
175
176
KITCHEN
151
1770
2251
83
112
DEN
179
3847
3307
181
164
rOCAT o\I
090
nOnn
nooe
Ivv
.Inn
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2018-Nov-08 11:00:33
}
c wrightSOft RlghtSuite® Universal 201212.1.05 RSU02818 Page 1
vrc& C1UsersUasonTowmentsMdghtsoft WACWW-68.rup Calc=MJ8 Front Door faces: S
Entire House
1831
24800
23546
1167
1167
Other equip loads
0
0
Equip. @ 0.95 RSM
22487
Latentcooling -- --
— —--
-----
—_— 12153_
Tl1TAIC
ne0nn
I 0u0.In
I
.. u.w rvo. ctVVV V7V7V IIV/ IIV!
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed,
2018-Nov-08 11:00:33
�C wrightSoft RightSuite® Universal 201212.1.05 RSU02818 Paget
%A+� C:lUsemUason\Documents\Wrlghtsoft HVACkMW-68.mp Cale =MJB Front Door faces: S
- wrightsoft Project Summary Date: Nov6,2018
Entire House By:
Project Information
For: MW-68
2632 CONIFER DR, FORT PIERCE, FL 34951
Notes:
Design Information
Weather:
Winter Design Conditions
Outside db
43
OF
Inside db
70
OF
Design TD
27
OF
Heating Summary
Structure
21595
Btuh
Ducts
3205
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
24800
Btuh
Infiltration
Method
Construction quality
Fireplaces
Vero Beach Municipal AP, FL, US
Simplified
Average
0
Heating
Cooling
Area (fta)
1831
1831
Volume (ft3)
18087
18087
Air changes/hour
0.38
0.20
Equiv. AVF (cfm)
115
60
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
7.3 kW
24817 Btuh
19 OF
1167 cfm
0.047 cfm/Btuh
0 in H2O
Summer Design Conditions
Outside db
91
OF
Inside db
72
OF
Design TO
19
OF
Daily range
L
Relative humidity
50
%
Moisture difference
65
gr/lb
Sensible Cooling Equipment Load Sizing
Structure
20108
Btuh
Ducts
3438
Btuh
Central vent (0 cfm)
0
Btuh
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipment sensible load
22487
Btuh
Latent Cooling Equipment Load Sizing
Structure
10617
Btuh
Ducts
1536
Btuh
Central vent (0 cfm)
0
Btuh
Equipment latent load
12153
Btuh
Equipment total load
34640
Btuh
Req. total capacity at 0.70 SHR
2.7
ton
Cooling Equipment Summary
Make Carrier
Trade 16 SEER PURON AC
Cond CA16NA036""A
Coil FV4CNB006
AHRI ref 4584643
Efficiency 13.7 EER, 16.5
SEER
Sensible cooling
24500
Btuh
Latent cooling
10500
Btuh
Total cooling
35000
Stuh
Actual air flow
1167
cfm
Air flow factor
0.050
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat ratio
0.66
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
htsoft 201&Nov-0811:00:33
W11
g RightSulle® Universal 201212.1.05 RSU02818 Page 1
C:11.1sersllasonTocumentslWrightsoft 1-1VACNW-88.rup Calc=MJ8 Front Door faces: 8
C
D
N
O
N
C_
n'o
im
�m
ne
�m
3
z
z
O
Fy
m
x
z
AO
O
'O
0
O
33�
Ym
y
:
N'•
i
mfN
� Fa
Z
9-1
xA '
, C ❑
m
iw
w4
C
i x
N g+
0
C A
�a
F
O
D
L
p
S
_
�F�
o
2
D
0
y
n°a
a
GHO HOME5
MW-68
2632 CONIFER OP.
FORT PIERCE, FL 34951
Planning & Development Service D
• Building & Code Regulations Divisi
_ _ _ 2300 Virginia Avenue, Fort Pierce, FL 34982 —1
Certification for Design Load
Project Name:
-- JAN-O
ST. Lucie County, permitting
Permit #: Occupancy Type: Construction Type:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the fallowing:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 160 mph X ASD _LRFD End Zone Width: 6 ft
5. Mean Roof Height 19 ft Roof Pitch: 6 :12 Parapet N/A ft
6. Components &Cladding Deign Pressures Used: (PSF, based on 10sgft @ MRH, dearly label on all plan openings
f-ZD• *00. 0 t3Y.� t3�/.'3 d Z .
Zone 1: — M. A Zone 2: —5313 Zone 3: — Y1,. - Zone 4: —V. d Zone 5: —Yd - Garage: ^ 27,
7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: WA PSF
Dock: N/A PSF Deck: N/A psF stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? Yes _NotApplicable Explain Why Not:
Ak j0, ;- 7- U-7- 4i , 40 • i
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Print Name Cert # & Co. Cert Auth.
sl re, DateVansea l.(f,3`/ sLcJ 24L✓t�n/� S.
r° Company Name & Address
,O3Revised 07/25/2, ` �
_ Planning & Development Services Department
5 - Building & Regulations Division
c
Product Review Affidavit
Building Permit #
p le-- aw-° I
owners Name / s a do uJ uu d LiiC . Applicant:
L "C0 F
ST Lu a Perrnitting
ounty
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
T vDo
Method of Attachment
Windows 1
+31.9 / -34.7
+/-55
MI WINDOWS
FL 17499.1
MPACT
3/16" TAPCONS W/ 1-1/4" MIN. EMBED @ 10" 01C
Mullions
37.7
+/-54
MI WINDOWS
FL 15353.31 FL 15353.4
IMPACT
1/4" TAPCONS W/ 1-1/4" MIN. EMBED
Fixed Glass j
+3.3.4 / -36.3
+/- 55
MI WINDOWS
FL 15349:5
IMPACT
3116" TAPCONS W/ 1-1/4" MIN. EMBED EQ. SPACING
Block Glass
Skylights
Sliding Glass Doors
Swing Type, ,Doors
+28.4 / -31.2
+31.9 /-34.7
+/-55
+/-50
MI WINDOWS
THERMATRU
12080
2880
FL-22401.3
FL-7630.1
IMPACT
IMPACT
3/16" TAPCONS W/ 1-1/4" MIN. EMBED @ 12" O/C
1/4" TAPCONS W/ 1-1/4" MIN. EMBED 14" O/C
French Doors
Garage Doors
+24.9 / -27.7
+39.2 / -43.7
WAYNE DALTON
9100
FL-9174.10 R12
N/A
(2) 3/8" TITEN SCREWS EA. BRACKET
Hurricane Plrotection
Roof Ventilation
Roofing Material
-83.4 PSF
-172PSF
�°�°^"°°"°�°�°
BELAIRCONC.TILE
NOAN0.17.0822.13
N/A
(2)10d RING SHANK NAILS
07/22/2014
I have reviewed the above components or cladding and I have approveIthei se in this strain e. Th a products provide adequat esi§ta a to the
wind loads and forces specified by current code provisions.
Name:jVfj LLs6- e/L&�ugYN� Signature: mlDesign Prot �Dyen'O FT /IiJi�[6� Cert No. $� Date: /2 l
.I
FORM R405-2017 FILE C01P f ""
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING COI
Florida�epartmen of -Business and-ProfessionaFRegulation---Residential-P-erfo
490 41,
i DICTION
;4 .project Name: M`8^(-68
Builder Name: GHO HOMES
+. ''street: 2; 2 CONIFER DR
Permit Office: ST. LUCIE COUNTY BLDG DPTMNT
City, State, Zip: FORT PIERCE, FL,
34951
Permit Number:
_Ob
2,Ya
Owner:
Jurisdiction:9151
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 j
1. New construction or existing
New (From Plans)
9. Wall Types (1830.1 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 1632.60 ft'
b, Frame - Wood, Adjacent
R=11.0 197.56 ft'
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
2
d. N/A
R= ft2
5. is this a worst case?
No
10. Ceiling Types (1832.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1832.00 ft'
6. Conditioned Floor area above grade (ft2)
1832
b. NIA
R= ft2
- .,conditioned floor area below grade (W)
0
c. N/A
R= ft2
11. Ducts
R ft'
7. Windows(263.7 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Main
6 629
a!U-Factor: Dbl, U=0.62
263.67 112
.. SHGC: SHGC=0.26
b. U-Factor: N/A
ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
36.0 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
24.8 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
0.000 ft.
Area Weighted Average SHGC:
0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1832.0 sqft.)
Insulation Area
EF: 0.900
a. Slab -On -Grade Edge Insulation
R=0.0 1832.00 ft'
b. Conservation features
• b. N/A
R= ft2
None
c:'N/A
R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.144
Total Proposed Modified Loads: 57.55
PASS
Total Baseline Loads: 61.28
..I hereby ce ' that the plans and specifications covered by
Review of the plans and
STATE
this calculation a in c pliance ith the Florida Energy
specifications covered by this
01214E
y a O
Code.
calculation indicates compliance
-
tti +;;oz'°''..•'� �0
with the Florida Energy Code.
rrm'-; ,�
PREPARED B
DATE: 1_
Before construction is completed
this building will be inspected for
compliance with Section 553.908
O y
t ,
I hereby certify t Is bui r g-a�desig
ad, is in compliance
Florida Statutes.
y�
with the Florid nergy od .
COp (4v
...OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
J2
DATE:
„- Compliance requires certifica4lon by the air handler unit manufacturer that the air handler enclosure qualifies as
'i'•y certified factory -sealed in accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance w R402.4 IA- d tom. +-requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.Ilk"E C EIi/E
JAN 2 2 2019
1/171201910:57 AM EnergyGauge®USA Section R405.4.1 Compliant Softwar Permitting DeparbWrz
F. St, Lucie County, FL
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
--title.
Building Type:
.. Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-68 __Bedrooms: 2
User Conditioned Area: 1832
Total Stories: 1
1 Worst Case: No
GHO N�MES Rotate Angle: 0
ST. LME COUNTY BLDG D Cross Ventilation: No
Whole House Fan: No
Single-family
New (From Plans)
Address Type:
Lot# —----
BlocWSubdivlsion:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
---
2632 CONIFER DR
St. Lucie
FORT PIERCE,
FL. 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62 Low
BLOCKS
Number
Name
Area Volume
1•
Blockl
1832 17037.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled Heated
1
Main
1832 17037.6 Yes 3
2
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 166.5 ft 0
1832 ft-
-_-
0 0 1
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Concrete 2049 ft' 0 ft' Medium
0.4
N 0.9
No 0 26.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1832 ft-
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Free Truss Type
1
Under Attic (Vented)
Main 30 Blown
1832 ft- 0.1
Wood
1/17/2019 10:57 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
-
Adjacent- --S ace-
P
Cavi Width
--Ft--��
Height
Sheathing Framing Solar
Below
mt
r� Wa�L$ype a_vaiue-Et-Jn
-
-Area R taalua=Fr ction-Absou-Grad °
_ 1
N
Exterior Concrete Block - Exl Insul Main
4 43 7 9
4
406.8 ft'
0
0 0.3
0
_ 2
E
Exterior Concrete Block - Exl Insul Main
4 53 10 9
4
502.4 ft'
0
0 0.3
0
3
S
Exterior Concrete Block - Ext Insul Main
4 19 6 9
4
182.0 ft'
0
0 0.3
0
y
-4
W
Exterior Concrete Block - Exl Insul Main
4 58 0 9
4
541.3 fP
0
0 0.3
0
5
-
Garage Frame - Wood Main
11 21 2 9
4
197.6 ft'
0
0.25 0.3
0
-
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
=�
Ft
In
Ft In
1
S Wood Main
None
.39
3
8
24 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
n 1 Metal Double (Clear) Yes
0.62 0.26 N
30.0 ft'
0 ft 0 in
0 ft 0 in
None
None
2
n 1 Metal Double (Clear) Yes
0.62 0.26 N
36.0 ft'
0 ft 0 In
0 It 0 in
None
None
3
n 1 Metal Double (Clear) Yes
0.62 0.26 N
96.0 ft'
0 ft 0 in
0 ft 0 in
None
None
4
e 2 Metal Double (Clear) Yes
0.62 0.26 N
12.0 ft'
0 ft 0 in
0 ft 0 in
None
None
5
e 2 Metal Double (Clear) Yes
0.62 0.26 N
7.0 ft'
0 ft 0 in
0 It 0 in
None
None
6
e 2 Metal Double (Clear) Yes
0.62 0.26 N
21.7 ft'
0 ft 0 in
0 ft 0 in
None
None
7
s 3 Metal Double (Clear) Yes
0.62 0.26 N
26.0 ft'
0 ft 0 in
0 ft 0 in
None
None
8
w 4 Metal Double (Clear) Yes
0.62 0.26 N
20.0 ft'
0 ft 0 in
0 ft 0 in
None
None
9
W 4 Metal Double (Clear) Yes
0.62 0.26 N
15.0 ft'
0 ft 0 in
0 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
584 ft' 584 ft'
64 ft
8 ft
1
INFILTRATION
...#
Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
-1 -Wholehouse Proposed ACH(50) .000295
1419.8 77.95 146.59
.224
5
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heal/ None
COP:1
24.82 kBtu/hr
1
sys#1
Ill 712019 10:57 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
## System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 16
36 kBt—u7ti-r—
1080�—cfm
0.7
1--sys#1--
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.9 50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
:-t Carl # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
:. _ / —Supply--
V # Location R-Value Area
—Return—
Location Area Leakage Type
Air
Handler
CFM 25
TOT
CFM25
OUT
ON
RLF
HVAC#
Heat Cool'
1 Attic
6 629 ft-
Attic
515 ft' Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Jan Feb
Venting Jan Feb
Mar
Mar
Ceiling Fans:Cooling
A Junrr[[ ]J
Apr [ May Jun tx1 Jul
rr[` ]J
ri Aug
Sep
r
8c!Sep Oct
[[X�]] v
lxl Nov
Dec
Dec
':Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6 7
8
9
10
11
12
Cooling (WD) AM
PM
Cooling (WEH) AM
PM
Heating (WD) AM
PM
Heating (WEH) AM
PM
78
80
78
78
66
68
66
68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78
78 78 78
78 78 78
78 78 78
66 66 68
68 68 68
66 66 68
68 68 68
78
78
78
78
68
68
68
68
78
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft'
0 ft
0.3
Main
Name: Signature:
Rating Compant:
Date:
1/17/2019 10:57 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE -LEVEL (EPL)-DISPLAY-CARD-
ESTIMATED ENERGY PERFORMANCE INDEX" = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
-
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 2
13. Cooling system: Capacity
36.0
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1832
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.620
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.260
14. Heating system: Capacity
24.8
c) Area
7c. 263.7
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.90
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a. 30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Cade, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy
Conservation, through the above energy
saving features which will be inst lied (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed b ed on installed
code compliant features.
►�1 I q
Builder Signature:
Date:
Address of New Home: 26 NIFER DR
City/FL Zip: FORT PIERCE, FL 34951
1/1712019 10:58:04 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software
Page 1 of 1