Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE - FILE COPYFORM R405-2017 Zoi - oar FILE COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business anctProfessional-Regulation-Residential-PP-erforrnance-Method Project Name: MW-68 Builder Name: RECEIVED Street: 2632 CONIFER DR Permit Office: City; State, Zip: FORT PIERCE, FL, 34951 Permit Number. JAN 0 2 2019 Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (FI rATIPMEW68no 2 )Permittinu unty, 1. New construction or existing New (From Plans) 9. Wall Types (1830.1 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 1632.60 ft2 b. Frame - Wood, Adjacent R=11.0 197.56 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. WA R= ft 5. Is this a worst case? No 10. Ceiling Types (1832.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1832.00 ft= 6. Conditioned floor area above grade (ft2) 1832 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(263.7 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Mal 6 629 �CgNNED a. U-Factor: Dbl, U=0.62 263.67 ft2 SHGC: SHGC=0.26 12. Cooling BYkBtulhr b. U-FactoNIA ft2 systems `St Efficiencyr. SHGC: a. Central Unit Lucie C 36.0 SEER:16.00 olint c. U-Factor: NIA ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. NIA ft2 a. Electric Strip Heat 24.8 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems 8. Floor Types (1832.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1832.00 ft2 b. Conservation features EF: 0.900 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Patel Glass/Floor Area: 0.144 Total Proposed Modified Loads: 57.55 PASS Total Baseline Loads: 61.28 1 hereby certify that the plans and specifications covered by Review of the plans and ST't?E. this calculation are in compliance with the Florida Energy specifications covered by this �F4HE = O� Code. ^ v� *V4--- calculation indicates compliance the Florida Energy Code. q iii, =;Z-' A (• •.; >,,.• with nu,. n „ O PREPARED BY: Before construction is completed r O DATE; 11/8/18 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. .� with the Florida Eneer/r@y��C''ottde.nn�� nn--..,,'' ��II OOp WE OWNER/AGENT 4AA:t� UCb-UAL BUILDING OFFICIAL: DATE: 11 DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 11/8/2018 11:20 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT — Title:— — — Building Type: Owner Name: # of Units: Builder Name: Permit Office: " Jurisdiction: Family Type: New/Existing: — Comment: —MW-68- — — — User 1 Single-family New (From Plans) — — —_—_.Bedrooms:— _ 2 _ Conditioned Area: 1832 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Lot -#-- Block/Subdivision: PlalBook: Street: County: City, State, Zip: Street Address 2632 CONIFER DR St. Lucie FORT PIERCE, FL, 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockt 1832 17037.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1832 17037.6 Yes 3 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 166.5 ft 0 1832 ft- ---- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Concrete 2049 ft' 0 ft' Medium 0.4 N 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1832 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Double Batt 1832 ft' 0.1 Wood 11/8/2018 11:20 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS -- rnt Adjacent - Cavity Width Height In WaLLSype -Space-R-glueEraction--Absoc--Grade/_ Sheathing Framing Solar Below _ 1 N Exterior Concrete Block - Ext Insul Main 4 43 7 9 4 406.8 ft2 0 0 0.3 0 -2 E Exterior Concrete Block - Ext Insul Main 4 53 10 9 4 502.4 ft2 0 0 0.3 0 -3 S Exterior Concrete Block - Ext Insul Main 4 19 6 9 4 182.0 ft' 0 0 0.3 0 ._4 W Exterior Concrete Block - Ext Insul Main 4 58 0 9 4 541.3 ft' 0 0 0.3 0 5 - Garage Frame - Wood Main 11 21 2 9 4 197.6 ft2 0 0.25 0.3 0 - DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Main None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. _ / Wall Overhang V # Omt 10 Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 30.0 ft2 0 It 0 in 0 It 0 in None None _ 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 36.0 ft2 0 ft 0 in 0 It 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.26 N 96.0 ft- 0 It 0 in 0 ft 0 in None None 4 e 2 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft- 0 It 0 in 0 ft 01n None None 5 e 2 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft2 0 ft 0 in 0 ft 0 in None None _ 6 e 2 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 0 ft 0 in 0 It 0 in None None _ 7 s 3 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft2 0 ft 0 in 0 ft 0 in None None 8 w 4 Metal Double (Clear) Yes 0.62 0.26 N 20.0 ft- 0 It 0 in 0 It 0 in None None 9 W 4 Metal Double (Clear) Yes 0.62 0.26 N 15.0 ft2 0 ft 0 in 0 It 0In None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 584 ft2 584 ft2 64 ft 8 It 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000295 1419.8 77.95 146.59 .224 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 24.82 kBtu/hr 1 sys#1 11/8/2018 11:20 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM _# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 36 kBtu/h-r----T089-cfm—0.7--I- —sys#1--- HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnl Conservation 1 Electric None Garage 0.9 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS _ / —Supply— Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 629 ft' Attic 515 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programabire,Thermostat: CFans: ]]Y Heatng Jan [X] Feb [[ �� [X] Mar Aprrreiling Apr [[XX]] Jay un I I Jul fXI [ ] Aug rX� [ ] Sep � rD0' Dec rD0' Ventl I 1 Jan l 1 Feb l l lX) Mar [ May l l Jun I) Jul I ] Aug [ ] Sep Oct [X] Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Healing(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' Oft 0.3 Main Name: Rating Compant: Signature: Date: 11/8/2018 11:20 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL-)-DISPLAY CARD-- - ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity36.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1832 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 c) Area 7c. 263.7 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.0 14. Heating system: Capacity24.8 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.90 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 1081. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied Pith the Florida Building Code, Energy Conservation, through the above energy saving features which will be installs (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed basecfQn installed code compliant features. Builder Address of New Home: Date: City/FL Zip: FORT PIERCE, FL 34951 11/8/2018 11:20:28 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1 -- wrightsoft. Load Short Form Entire House For: MW-68 2632 CONIFER DR, FORT PIERCE, FL 34951 Job: Date: Nov 6, 2018 By: Design Information Htg Clg Infiltration Outside db (°F) 43 91 Method Simplified Inside db (°F) 70 72 Construction quality Average Design TD (°F) 27 19 Fireplaces 0 Daily range - L Inside humidity (°/a) 30 50 Moisture difference (gr/lb) 0 65 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.3 kW 24817 Btuh 19 °F 1167 cfm 0.047 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make Carrier Trade 16 SEER PURON AC Cond CA16NA036""A Coil FV4CNB006 AHRI ref 4584643 Efficiency 13.7 EER, 16.5 SEER Sensible cooling 24500 Btuh Latent cooling 10500 Btuh Total cooling 35000 Btuh Actual air flow 1167 cfm Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.66 ROOM NAME Area W) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 312 5079 3663 239 181 HER WIC 60 941 432 44 21 MASTER BATH 169 1815 1830 85 91 BED 2 205 2427 2881 114 143 UTILITY 72 599 920 28 46 BATH 2 79 78 218 4 11 FOYER 100 792 608 37 30 DINING 130 3727 3552 175 176 KITCHEN 151 1770 2251 83 112 DEN 179 3847 3307 181 164 rOCAT o\I 090 nOnn nooe Ivv .Inn Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Nov-08 11:00:33 } c wrightSOft RlghtSuite® Universal 201212.1.05 RSU02818 Page 1 vrc& C1UsersUasonTowmentsMdghtsoft WACWW-68.rup Calc=MJ8 Front Door faces: S Entire House 1831 24800 23546 1167 1167 Other equip loads 0 0 Equip. @ 0.95 RSM 22487 Latentcooling -- -- — —-- ----- —_— 12153_ Tl1TAIC ne0nn I 0u0.In I .. u.w rvo. ctVVV V7V7V IIV/ IIV! Calculations approved by ACCA to meet all requirements of Manual J 8th Ed, 2018-Nov-08 11:00:33 �C wrightSoft RightSuite® Universal 201212.1.05 RSU02818 Paget %A+� C:lUsemUason\Documents\Wrlghtsoft HVACkMW-68.mp Cale =MJB Front Door faces: S - wrightsoft Project Summary Date: Nov6,2018 Entire House By: Project Information For: MW-68 2632 CONIFER DR, FORT PIERCE, FL 34951 Notes: Design Information Weather: Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 21595 Btuh Ducts 3205 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 24800 Btuh Infiltration Method Construction quality Fireplaces Vero Beach Municipal AP, FL, US Simplified Average 0 Heating Cooling Area (fta) 1831 1831 Volume (ft3) 18087 18087 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 115 60 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.3 kW 24817 Btuh 19 OF 1167 cfm 0.047 cfm/Btuh 0 in H2O Summer Design Conditions Outside db 91 OF Inside db 72 OF Design TO 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Sensible Cooling Equipment Load Sizing Structure 20108 Btuh Ducts 3438 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 22487 Btuh Latent Cooling Equipment Load Sizing Structure 10617 Btuh Ducts 1536 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 12153 Btuh Equipment total load 34640 Btuh Req. total capacity at 0.70 SHR 2.7 ton Cooling Equipment Summary Make Carrier Trade 16 SEER PURON AC Cond CA16NA036""A Coil FV4CNB006 AHRI ref 4584643 Efficiency 13.7 EER, 16.5 SEER Sensible cooling 24500 Btuh Latent cooling 10500 Btuh Total cooling 35000 Stuh Actual air flow 1167 cfm Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.66 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. htsoft 201&Nov-0811:00:33 W11 g RightSulle® Universal 201212.1.05 RSU02818 Page 1 C:11.1sersllasonTocumentslWrightsoft 1-1VACNW-88.rup Calc=MJ8 Front Door faces: 8 C D N O N C_ n'o im �m ne �m 3 z z O Fy m x z AO O 'O 0 O 33� Ym y : N'• i mfN � Fa Z 9-1 xA ' , C ❑ m iw w4 C i x N g+ 0 C A �a F O D L p S _ �F� o 2 D 0 y n°a a GHO HOME5 MW-68 2632 CONIFER OP. FORT PIERCE, FL 34951 Planning & Development Service D • Building & Code Regulations Divisi _ _ _ 2300 Virginia Avenue, Fort Pierce, FL 34982 —1 Certification for Design Load Project Name: -- JAN-O ST. Lucie County, permitting Permit #: Occupancy Type: Construction Type: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the fallowing: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 mph X ASD _LRFD End Zone Width: 6 ft 5. Mean Roof Height 19 ft Roof Pitch: 6 :12 Parapet N/A ft 6. Components &Cladding Deign Pressures Used: (PSF, based on 10sgft @ MRH, dearly label on all plan openings f-ZD• *00. 0 t3Y.� t3�/.'3 d Z . Zone 1: — M. A Zone 2: —5313 Zone 3: — Y1,. - Zone 4: —V. d Zone 5: —Yd - Garage: ^ 27, 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: WA PSF Dock: N/A PSF Deck: N/A psF stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? Yes _NotApplicable Explain Why Not: Ak j0, ;- 7- U-7- 4i , 40 • i 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Print Name Cert # & Co. Cert Auth. sl re, DateVansea l.(f,3`/ sLcJ 24L✓t�n/� S. r° Company Name & Address ,O3Revised 07/25/2, ` � _ Planning & Development Services Department 5 - Building & Regulations Division c Product Review Affidavit Building Permit # p le-- aw-° I owners Name / s a do uJ uu d LiiC . Applicant: L "C0 F ST Lu a Perrnitting ounty Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass T vDo Method of Attachment Windows 1 +31.9 / -34.7 +/-55 MI WINDOWS FL 17499.1 MPACT 3/16" TAPCONS W/ 1-1/4" MIN. EMBED @ 10" 01C Mullions 37.7 +/-54 MI WINDOWS FL 15353.31 FL 15353.4 IMPACT 1/4" TAPCONS W/ 1-1/4" MIN. EMBED Fixed Glass j +3.3.4 / -36.3 +/- 55 MI WINDOWS FL 15349:5 IMPACT 3116" TAPCONS W/ 1-1/4" MIN. EMBED EQ. SPACING Block Glass Skylights Sliding Glass Doors Swing Type, ,Doors +28.4 / -31.2 +31.9 /-34.7 +/-55 +/-50 MI WINDOWS THERMATRU 12080 2880 FL-22401.3 FL-7630.1 IMPACT IMPACT 3/16" TAPCONS W/ 1-1/4" MIN. EMBED @ 12" O/C 1/4" TAPCONS W/ 1-1/4" MIN. EMBED 14" O/C French Doors Garage Doors +24.9 / -27.7 +39.2 / -43.7 WAYNE DALTON 9100 FL-9174.10 R12 N/A (2) 3/8" TITEN SCREWS EA. BRACKET Hurricane Plrotection Roof Ventilation Roofing Material -83.4 PSF -172PSF �°�°^"°°"°�°�° BELAIRCONC.TILE NOAN0.17.0822.13 N/A (2)10d RING SHANK NAILS 07/22/2014 I have reviewed the above components or cladding and I have approveIthei se in this strain e. Th a products provide adequat esi§ta a to the wind loads and forces specified by current code provisions. Name:jVfj LLs6- e/L&�ugYN� Signature: mlDesign Prot �Dyen'O FT /IiJi�[6� Cert No. $� Date: /2 l .I FORM R405-2017 FILE C01P f "" FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING COI Florida�epartmen of -Business and-ProfessionaFRegulation---Residential-P-erfo 490 41, i DICTION ;4 .project Name: M`8^(-68 Builder Name: GHO HOMES +. ''street: 2; 2 CONIFER DR Permit Office: ST. LUCIE COUNTY BLDG DPTMNT City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: _Ob 2,Ya Owner: Jurisdiction:9151 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 j 1. New construction or existing New (From Plans) 9. Wall Types (1830.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 1632.60 ft' b, Frame - Wood, Adjacent R=11.0 197.56 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. is this a worst case? No 10. Ceiling Types (1832.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1832.00 ft' 6. Conditioned Floor area above grade (ft2) 1832 b. NIA R= ft2 - .,conditioned floor area below grade (W) 0 c. N/A R= ft2 11. Ducts R ft' 7. Windows(263.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 629 a!U-Factor: Dbl, U=0.62 263.67 112 .. SHGC: SHGC=0.26 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 36.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 24.8 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1832.0 sqft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 1832.00 ft' b. Conservation features • b. N/A R= ft2 None c:'N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.144 Total Proposed Modified Loads: 57.55 PASS Total Baseline Loads: 61.28 ..I hereby ce ' that the plans and specifications covered by Review of the plans and STATE this calculation a in c pliance ith the Florida Energy specifications covered by this 01214E y a O Code. calculation indicates compliance - tti +;;oz'°''..•'� �0 with the Florida Energy Code. rrm'-; ,� PREPARED B DATE: 1_ Before construction is completed this building will be inspected for compliance with Section 553.908 O y t , I hereby certify t Is bui r g-a�desig ad, is in compliance Florida Statutes. y� with the Florid nergy od . COp (4v ...OWNER/AGENT: BUILDING OFFICIAL: DATE: J2 DATE: „- Compliance requires certifica4lon by the air handler unit manufacturer that the air handler enclosure qualifies as 'i'•y certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance w R402.4 IA- d tom. +-requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.Ilk"E C EIi/E JAN 2 2 2019 1/171201910:57 AM EnergyGauge®USA Section R405.4.1 Compliant Softwar Permitting DeparbWrz F. St, Lucie County, FL FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT --title. Building Type: .. Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-68 __Bedrooms: 2 User Conditioned Area: 1832 Total Stories: 1 1 Worst Case: No GHO N�MES Rotate Angle: 0 ST. LME COUNTY BLDG D Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) Address Type: Lot# —---- BlocWSubdivlsion: PlatBook: Street: County: City, State, Zip: Street Address --- 2632 CONIFER DR St. Lucie FORT PIERCE, FL. 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1• Blockl 1832 17037.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1832 17037.6 Yes 3 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 166.5 ft 0 1832 ft- -_- 0 0 1 ROOF V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Concrete 2049 ft' 0 ft' Medium 0.4 N 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1832 ft- N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) Main 30 Blown 1832 ft- 0.1 Wood 1/17/2019 10:57 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS - Adjacent- --S ace- P Cavi Width --Ft--�� Height Sheathing Framing Solar Below mt r� Wa�L$ype a_vaiue-Et-Jn - -Area R taalua=Fr ction-Absou-Grad ° _ 1 N Exterior Concrete Block - Exl Insul Main 4 43 7 9 4 406.8 ft' 0 0 0.3 0 _ 2 E Exterior Concrete Block - Exl Insul Main 4 53 10 9 4 502.4 ft' 0 0 0.3 0 3 S Exterior Concrete Block - Ext Insul Main 4 19 6 9 4 182.0 ft' 0 0 0.3 0 y -4 W Exterior Concrete Block - Exl Insul Main 4 58 0 9 4 541.3 fP 0 0 0.3 0 5 - Garage Frame - Wood Main 11 21 2 9 4 197.6 ft' 0 0.25 0.3 0 - DOORS # Ornt Door Type Space Storms U-Value Width Height Area =� Ft In Ft In 1 S Wood Main None .39 3 8 24 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 30.0 ft' 0 ft 0 in 0 ft 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 36.0 ft' 0 ft 0 In 0 It 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.26 N 96.0 ft' 0 ft 0 in 0 ft 0 in None None 4 e 2 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft' 0 ft 0 in 0 ft 0 in None None 5 e 2 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft' 0 ft 0 in 0 It 0 in None None 6 e 2 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft' 0 ft 0 in 0 ft 0 in None None 7 s 3 Metal Double (Clear) Yes 0.62 0.26 N 26.0 ft' 0 ft 0 in 0 ft 0 in None None 8 w 4 Metal Double (Clear) Yes 0.62 0.26 N 20.0 ft' 0 ft 0 in 0 ft 0 in None None 9 W 4 Metal Double (Clear) Yes 0.62 0.26 N 15.0 ft' 0 ft 0 in 0 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 584 ft' 584 ft' 64 ft 8 ft 1 INFILTRATION ...# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 -1 -Wholehouse Proposed ACH(50) .000295 1419.8 77.95 146.59 .224 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heal/ None COP:1 24.82 kBtu/hr 1 sys#1 Ill 712019 10:57 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM ## System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 36 kBt—u7ti-r— 1080�—cfm 0.7 1--sys#1-- HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC :-t Carl # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS :. _ / —Supply-- V # Location R-Value Area —Return— Location Area Leakage Type Air Handler CFM 25 TOT CFM25 OUT ON RLF HVAC# Heat Cool' 1 Attic 6 629 ft- Attic 515 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Jan Feb Venting Jan Feb Mar Mar Ceiling Fans:Cooling A Junrr[[ ]J Apr [ May Jun tx1 Jul rr[` ]J ri Aug Sep r 8c!Sep Oct [[X�]] v lxl Nov Dec Dec ':Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM Cooling (WEH) AM PM Heating (WD) AM PM Heating (WEH) AM PM 78 80 78 78 66 68 66 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 66 66 68 68 68 68 78 78 78 78 68 68 68 68 78 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 78 78 78 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main Name: Signature: Rating Compant: Date: 1/17/2019 10:57 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE -LEVEL (EPL)-DISPLAY-CARD- ESTIMATED ENERGY PERFORMANCE INDEX" = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level - a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 36.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1832 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 24.8 c) Area 7c. 263.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.90 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Cade, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be inst lied (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed b ed on installed code compliant features. ►�1 I q Builder Signature: Date: Address of New Home: 26 NIFER DR City/FL Zip: FORT PIERCE, FL 34951 1/1712019 10:58:04 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1