PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING THE SQUARE FOOT INFORMATION. SEE
CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE SIXTH EDTITION.
THE ENERGY CALULATIONS MUST HAVE THE PREPARERS ORIGINAL SIGNATURE PLEASE FURNISH NEW ENERGY CALULATIONS WITH ORIGINAL
SIGNATURES PER 107.1 OF THE 2017 FLORIDA BUILDING CODE
ENERGY CALCS INFORMATION BLOCK AT THE TOP OF THE PAGE IS INCOMEPLETE BUILDERS NAME PERMIT OFFICE ARE MISSING. SEE SECTION
405.4.2 (1) OF THE 2017 FLORIDA ENERGY CODE.
2015 INTERNATIONAL
— - Plan Review 901-0020
y' RESIDENTIAL CODE® Date: 1/16/19
" FOR ONE- AND TWO-FAMILY DWELLINGS Valuation: $335,081.25
PLAN REVIEW RECORD Fee: $2409.21/$17,194.21
JURISDICTION: FORT PIERCE, FL 34951
(City, County, Township, etc.)
'BUILDING LOCATION: 2632 CONIFER DRIVE
._ - - (Street address)
BUILDING .DESCRIPTION: _ SFR
REVIEWED BY.L
Numerals indioatedin parenthesis are applicable code sections of the 2015 international Residential Code.(IRC), The plan reviewaccomplished as indicated
in this record is limited to those code sections specifically, identified herein. This recored references commonly applicable code sections with due regard for
the amount and type of detailed information which. is. typically found on construction document§ for one - and two-family dwellings and townhouses. I[ does,
' not reference all code'provision"s which; may be applicable to specific buildings. This record is designed to be used only by those who ere knowledgeable
and capable of exercising competentjudgment in evaluating constriction documents for code compliance. `;, , "� •. .
CORRECTIONS LIST
No.
DESCRIPTION
Code
Section
\� • • •s International e•-•• • • a • - ISBN 978-1-60983-611-5 is the • • s • in the Uc�,Patent
INTERKATITrademarkQfflce�• III IIIIIIIII IIIIIIIIII
•••• - • 9 781609 836115
INTERNATIONAL
CODE COUNCIL - • • - • r -
-1-
CORRECTION LIST (cont'd.)
No. DESCRIPTION Code
Section
-2-
NOTE: Entries to this Plan Review Record that require a field check or inspection of the installation must be coordinated with the inspection phase (R109) of the project.
BUILDING PLANNING (Chapter 3)
DESIGN CRITERIA [Table R301.2(1)] Parapets and construction
Floor live load (Table R301.5) psf (R302.2.2, R302.2.3)
Roof live load (Table R301.6) 30 psf Two-family dwelling separation (R302.3)
Ground snow load psf Dwelling unit penetrations (R302.4)
Ultimate design wind speed 160 mph
Wind exposure category (R301.2.1.4)?=C
High wind design criteria applicable
(R301.2.1.1)
Seismic design category (SDC)
[Figure R301.2(2)]
SDC C&D provisions (R301.2.2)
tnre�ae.1..., NEG
Frost line depth
Termite area VH
Decay area
Winter design temperature
Ice barrier underlayment required
Flood hazards
FIRE-RESISTANT CONSTRUCTION (R302)
Exterior walls
[R302.1, Tables R302.1(1) and R302.1(2)]
Townhouse separation (R302.2)
Continuity and structural independence
(17302.2.1, R302.2.4)
ROOM PLANNING REQUIREMENTS (R303 through R305)
Dwelling/garage opening/penetration protec-
tion (R302.5)
Dwelling/garage fire separation (R302.6)
Under -stair protection (R302.7)
Wall and ceiling finishes (R302.9)
Flame spread index (17302.9.1)
Smoke -developed index (R302.9.2)
Testing (R302.9.3, R302.9.4)
Insulation (13302.10)
Flame spread/smoke-developed
(R302.10.1, R302.10.2)
Cellulose loose -fill and exposed attic
insulation (R302.10.3, R302.10.4)
Testing (R302.10.5)
Fireblocking (R302.11)
Draftstopping (R302.12)
Fire protection of floors (R302.13)
Combustible insulation clearance (13302.14)
Use
Area (ft2)
Width
Ceiling heights
Natural light'
Natural ventilation'
Living
70
T-0"
7'-0"
8%floor area
4%floor area
Dining
70
T-0"
T-0"
8%floor area
4%floor area
Kitchen
N.A.
N.A.
T0"
8 % floor area
4%, floor area
Bedroom
70
T-0"
7'-0"
8%floor area
4%floor area
Bathroom
N.A.
N.A
6'-8"
3 square feet
11/z square feet
See Sections R303.1 & R303.3 for mechanical ventilation and artificial light and R303.4 for required whole -house mechanical ventilation.
t 6'-8" min. at plumbing fixtures and for non -habitable basements.
X Required heating (R303.9)
SANITATION (R306 and R307)
X Water closet
X Lavatory
X Tub or shower
X Kitchen area with sink
X Sanitary sewer (Chapter30)
X Private disposal (Appendix 1)
GLAZING (R308)
Identification (R308.1)
Louvered windows or jalousies (R308.2)
Human impact loads/hazardous locations
(R308.3, R308.4)
Skylights and sloped glazing (R308.6)
-3-
BUILDING PLANNING (cont'd.)
GARAGES AND CARPORTS (R309)
X Floor surface noncombustible; sloped floor
(R309.1)
Carport: open two sides; noncombustible
floors; sloped floor (R309.2)
Automatic garage door opener (R309.4)
Fire sprinklers (R309.5)
EMERGENCY ESCAPE AND RESCUE OPENINGS
(R310)
Where required (R310.1)
Areas, height, width, operations (13310)
Window wells (R310.2.3)
decks and porches (R310.2.4)
Bars, grilles, covers and screens (R310.4)
MEANS OF EGRESS (R311)
X General (17311.1)
X Egress door (R311.2)
Landings at exterior doors
(R311.3 - R311.3.3)
Vertical egress (R311.4)
Construction and attachment (R311.5)
X Hallways (R311.6)
Stairway width, headroom, vertical rise, walk -
line (11311.71 - R311.7.4)
Stairway treads, risers profiles
(R311.75 - R311.75.4)
Stairway landings and walking surfaces
(R311.76, R311.7.7)
Handrails required (17311.78)
Handrail height, continuity, grip -size
(R311.78.1 - R311.78.4)
Stairway illumination (17303.7, R311.79)
Special stairways (R311.710)
Ramp slope, landings, handrails (R311.8)
GUARDS AND WINDOW PROTECTION (R312)
Required for open -sided surfaces, stairs,
ramps and landings > 30" above floor/
grade (R312.1.1)
Height - 36" (R312.1.2)
Opening limitations (R312.1.3)
Window fall protection (R312.2)
AUTOMATIC FIRE SPRINKLER SYSTEMS (R313)
Townhouses (R313.1)
One- and two-family dwellings (R313.2)
SMOKE ALARMS (R314)
Referenced standards (R314.1)
Location and interconnection
(13314.3, R314.4)
Power source (R314.6)
CARBON MONOXIDE ALARMS (R315)
New construction (R315.1, R315.2)
Existing construction (R315.2.2)
Referenced standard (R315.6)
FOAM PLASTIC (R302.8, R316)
Labeling (R316.2)
Surface burning, thermal barrier, specific
approval (R316.3 - R316.8)
DECAY AND TERMITE PROTECTION (R317 and R318)
X Protection required
(Table R301.2(1), R317.1, R318.1)
Quality mark (133172 and R318.1.1)
SITE ADDRESS (R319)
Address numbers (R319.1)
ACCESSIBILITY (R320)
Type B dwelling units applicable (17320.1)
ELEVATORS/PLATFORM LIFTS (R321)
Referenced standards (R321.1 - R321.3)
FLOOD -RESISTANT CONSTRUCTION (R322)
General (R322.1)
Hazard area and requirements
(R301.2.4, R309.3, R322.2, R322.3)
Design professional (R322.3.6)
STORM SHELTERS (R323)
General/referenced standard (11323.1)
SOLAR ENERGY SYSTEMS (R324)
System, installation, access
(R324.2 - R324.7)
MEZZANINES (R325)
Area, egress, openness (R325.2 - R325.5)
SWIMMING POOLS, SPAS AND HOT TUBS (R326)
ISPSC (R326.1)
-4-
FOUNDATIONS (Chapter 4)
MATERIALS R402
Wood foundations (13402.1)
Concrete, compressive strength
(R402.2, R402.3)
FOOTINGS (R403)
x Soil bearing value (R401.4, R403.1)
x Footing width
(Tables R403.1(1) - R403.1(3)]
Footing edge thickness; footing projection =
2" minimum, but 5 footing thickness
(R403.1.1)
Footings in SDC and D
(R403.1.2 and R403.1.6.1)
x Depth below (outside) grade = 12" minimum;
but below frost line (R403.1.4, R403.1.4.1)
Sill plate bolting in concrete/masonry ='/2' di-
ameter bolts, within 12" but not less than 7
bolt diameters from ends, 7" embedment
(R403.1.6)
Footings adjacent to slopes (R403.1.7)
Frost -protected shallow foundations (R403.3)
Footings for precast concrete foundations
(R403.4)
FOUNDATION/RETAINING WALLS (R404 - R406)
Masonry foundation walls (R404.1.2)
Wall height, unbalanced backfill, nominal
thickness (Tables R404.1.1(1) -
R404.1.1(4), R404.1.5.1]
Reinforcement size and spacing
(Tables R404.1.1(2) - R404.1.1(4)]
Concrete foundation walls (R404.1.3)
Wall height, unbalanced backfill, nominal
thickness (Tables R404.1.2(1) -
R404.1.2(8), R404.1.5.2]
Horizontal and vertical reinforcement size and
spacingTi`ables-17404.1.2(1)=-- - - - -
R404.1.2(8), R404.1.3.2, R404.1.3.3.7]
Stay-in-place forms (R404.1.3.3.6.1)
SDC D provisions (R404.1.4)
Height above finished grade (R404.1.6)
Sill plate size (R404.3)
Precast concrete foundation walls (R404.5)
Drains required if habitable or usable spaces
are below grade* (R405)
Soil class (Table R405.1)
Dampproofing if basements are below grade*
(R406.1)
Waterproofing if high water table* (R406.2)
* If uninhabitable, see Under -Floor Space (13408)
COLUMNS (R407)
Protection from decay or corrosion
(17407.1 and R407.2)
x Structural requirements (R407.3)
Anchorage (R407.3)
Wood columns (minimum 4" square) (13407.3)
Steel columns (minimum 3" diameter, Sched-
ule 40 pipe) (R407.3)
UNDER -FLOOR SPACE (R408)
Ventilation (13408.1 and R408.2)
Unvented crawl space (R408.3)
Access (R408.4)
Removal of debris (R408.5)
Finished grade (R408.6)
Flood resistance (R408.7)
-5-
FLOORS (Chapter 5)
WOOD JOISTS AND GIRDERS (R502)
Species and grade (R502.1)
Joists —Sleeping areas, ILL = 30 psf
[Table R502.3.1(1)]
Joists—Nonsleeping areas, LL = 40 psf
[Table R502.3.1(2)]
Cantilevered joists —
[Tables R502.3.3(1) and R502.3.3(2)]
Girder and header spans
(Tables R602.7(1) - R602.7(3)]
Joists under bearing partitions (R502.4)
Bearing (1.5" minimum on wood or metal; 3"
on masonry or concrete) and lapped joists
(3") (13502.6, R502.6.1)
Lateral restraint and bridging
(17502.7, R502.7.1)
Drilling and notching (13502.8)
Fastening (R502.9)
Framing of openings (13502.10)
Wood trusses (17502.11)
Draftstopping (R502.12)
LUMBER FLOOR SHEATHING (R503.1)
Allowable span (Table R503.1)
End joints (R503.1.1)
WOOD STRUCTURAL PANEL SHEATHING (R503.2)
Grade (R503.2.1)
Thickness (R503.2.1)
Allowable spans
(Tables R503.2.1.1(1) and R503.2.1.1(2)]
Installation [Table 602.3(1)]
PARTICLEBOARD UNDERLAYMENT (R503.3)
Grade (R503.3.1)
Thickness (R503.3.2)
Installation [Table R602.3(1)]
TREATED -WOOD FLOORS (ON GROUND) (R504)
Base course: 4" thick with maximum %"
gravel or'/z" crushed stone (R504.2.1)
Moisture barrier: placed over base course
(R504.2.2)
Materials (R504.3)
STEEL FLOOR FRAMING (R505)
Cold -formed steel; applicability limits;
in -line framing (R505.1)
Structural framing (17505.2)
Material (13505.2.1)
Corrosion protection (R505.2.2)
Identification (R505.2.4)
Fastening (R505.2.5)
Floor construction (R505.3)
CONCRETE FLOORS (ON GROUND) (R506)
X Thickness: 31/2" minimum; Concrete strength
(R506.1)
Support: prepared subgrade; maximum earth
fill = 811; maximum sand or gravel fill = 24"
(R506.2.1)
Base course: 4" graded with 2" maximum
aggregate (R506.2.2)
X Vapor retarder (R506.2.3)
X Reinforcement support (R506.2.4)
EXTERIOR DECKS (R507)
Support, attachment (R5071 - R507.2.4)
Plastic composite materials (175073)
Decking/deckjoists (R5074, R5075)
Deck beams (R507.6)
Deck posts, connections, footings
(1750771, R507.8)
WALL CONSTRUCTION (Chapter 6)
WOOD -CONSTRUCTION (R602)_ Material (R603.2.1)
Construction
(Figures R602.3(1) and R602.3(2)]
Stud grade (R602.2)
Designkonstruction (R602.3)
Stud spacing [17602.3.1, Table R602.3(5)]
Interior load -bearing walls (R602.4)
X Interior nonbearing walls: 2" x 3" at 24" o.c.
or 2" x 4" flat at 16" o.c. (R602.5)
Drilling and notching —studs (R602.6)
Drilling and notching —top plate (R602.6.1)
Headers (Tables R602.7(1) - R602.7(3) and
Figure R602.7.2]
Fireblocking (R602.8, R302.11)
Cripple walls (R602.9)
Wall bracing, lines, panels
(R602.10.1, R602.10.2)
Required length of bracing, method
(R602. f0.3, R602.10.4, Tables
R602.10.3(1) and R602. f0.3(3)]
Minimum length, connections, support, joints,
cripple walls (17602.10.5 - R602.10.11)
Wall anchorage (SDC C and D) (17602.11)
Simplified wall bracing (R602.12)
STEEL WALL FRAMING (R603)
General (17603.1)
Structural framing (R603.2)
Corrosion protection (R603.2.2)
Identification (R603.2.4)
Fastening (R603.2.5)
Wall construction (R603.3 - R603.5)
Headers (R603.6)
Studs, tracks and structural sheathing
(R603.7 - R603.9)
SHEATHING (R604 and R605)
Wood structural panels (R604)
Particleboard (17605)
MASONRY CONSTRUCTION (R606 - R610)
X General design (R606)
Seismic requirements (R606.12)
Glass unit masonry (17607)
X Exterior concrete wall construction (R608)
X Exterior windowsldoors (R609)
_Glass unit masonry (R610)
STRUCTURAL INSULATED PANEL WALL
CONSTRUCTION (R610)
Applicability (R610.2)
Materials (R610.3)
Wall panels, construction details
(R610.4 - R610.10)
-7-
WALL COVERING (Chapter 7)
INTERIOR WALL COVERING (R702)
Plaster material (R702.2)
Plaster support (R702.2.3)
X Gypsum board materials (13702.3.1)
Gypsum board support, application and fas-
tening (R702.3.2 - R702.3.7)
X Ceramic tile. (R702.4) _
Other finishes (13702.5 and R702.6)
Vapor retarders (R702.7)
Wood shakes and shingles (R703.6)
Exterior plaster (R703.7)
Stone & masonry veneer (17703.8 & Figure
R703.8); Steel angle lintels-4" minimum
bearing each end (R703.8.3)
Veneer ties: #9 U.S. gage wire or #22 U.S.
gage by'/e' corrugated metal; horizontal
and vertical spacing; 2.67 square feet
maximum area supported (wind > 30 psf
and SDC C or D, maximum area = 2
square feet) (R703.8.4.1)
Flashing (13703.4 and R703.8.5)
EXTERIOR WALL COVERING (R703) Exterior insulation and finish systems
(R
X Water -resistive barrier (R703.2) X cement
Fiber cement siding (13703. 10)
Attachment and minimum thickness
(Table R703.3(1)) Vinyl siding (17703.11)
Wood siding (R703.5) Other sidings (R703.12 - R703.17)
ROOF -CEILING CONSTRUCTION (Chapter 8)
WOOD ROOF FRAMING (R802)
Fire -retardant -treated wood (17802.1.5)
X Framing details (R802.3)
Rafter ties (17802.3.1)
Collar ties (4' o.c., in upper third of attic)
(R802.3.1)
Purlins (2" x 4" at 4' o.c. minimum)
(Figure R802.5.1, R802.5.1)
Bearing (R802.6)
Cutting and notching (R802.7)
X Engineered wood products (R802.7.2)
Lateral support and bridging (R802.8)
X Framing of openings (R802.9)
X Wood trusses (13802.10)
X Roof tie -down (13802.11)
CEILING JOISTS [Tables R802.4(1), R802.4(2)]
Without attic storage, LL = 10psf
With attic storage LL = 20psf
Spacing
Species and grade
X Span
X Size
RAFTERS [Tables R802.5.1(1) - R802.5.1(8)]
Ground snow load/LL = 20 psf
Controlling design (LL or snow)
Ceiling not attached/ceiling attached
Spacing
Species and grade
Span
Size
H,,JHR; Adjustment factor
ROOF SHEATHING (R803.2)
Grade
X Thickness
FRTW allowable stresses/grading
X Allowable spans (Table R503.2.1.1(1))
X Installation (R803.2.3)
ME
ROOF -CEILING CONSTRUCTION (cont'd.)
STEEL ROOF FRAMING (R804) Roof construction (R804.3)
General (13804.1) Roof tie -down (R804.3.8)
Structural framing (R804.2) ROOF VENTILATION (R806)
Material (R804.2.1) X Ventilation requirements (R806.1 - R806.5)
Corrosion protection (R804.2.2)
Identification (17804.2.3)
Fastening (R804.2.5)
ATTIC ACCESS (R807)
X Access requirements (807.1)
ROOF ASSEMBLIES (Chapter 9)
ROOF CLASSIFICATION (R902)
X Roof covering materials (R902.1)
WEATHER PROTECTION (R903)
Flashing (R903.2)
Coping (R903.3)
Roof drainage (R903.4)
MATERIALS (R904)
Compatibility; specifications; physical charac-
teristics; identification (R904.2 - R904.4)
REQUIREMENTS FOR ROOF COVERINGS (R905)
X Underlayment (R905.1.1, R905.1.2)
Asphalt shingles (R905.2)
Clay and concrete tile (R905.3)
Metal roof shingles (R905.4)
Mineral -surfaced roll roofing (R905.5)
Slate shingles (R905.6)
Wood shingles (R905.7)
Wood shakes (13905.8)
Built-up roofs (R905.9)
X Metal roof panels (R905.10)
NOA / PA Modified bitumen roofing (R905.11)
NOA / PA Thermoset single -ply roofing (13905.12)
NOA / PA Thermoplastic single -ply roofing (R905.13)
NOA / PA Sprayed polyurethane foam roofing (R905.14)
NOA / PA Liquid -applied roofing (17905.15)
NOA / PA Photovoltaic shingles (17905.16)
ROOF INSULATION (R906)
General (R906.1)
ROOFTOP - MOUNTED PHOTOVOLTAIC SYSTEMS
(R907)
Materials and installation (R907.1 - R907.5)
REROOFING (R908)
Materials and methods (13908.1)
Structural support (R908.2)
Replacement/re-covering (R908.3, R908.4)
ROOFTOP - MOUNTED PHOTOVOLTAIC
PANEL SYSTEMS (R909)
Materials and installation (R909.1 - R909.3)
CHIMNEYS AND FIREPLACES (Chapter 10)
MASONRY FIREPLACES (R1001)
Construction
(Figure R1001.1 and Table R1001.1)
SDC D reinforcing/anchorage
(R1001.3 and R1001.4)
Firebox walls and dimensions
(R 1001.5 and R 1001.6)
Steel fireplace units (171001.5.1)
Lintel (noncombustible) (R1001.7)
Hearth extension (R1001.9, R1001.10)
Fireplace clearance (R1001.11)
Fireblocking (177001.12)
MASONRY CHIMNEYS (R1003)
Construction (Table R1001.1, R1003.2,
R1003.3, and Figure R1001.1)
Corbeling (171003.5)
In
CHIMNEYS AND FIREPLACES (cont'd.)
Changes in dimension (R1003.6)
Additional load (R1003.8)
Termination (R1003.9)
Spark arrestors (R1003.9.2)
Wall thickness; >_ 4" (R1003.10)
Flue lining - material/installation
(R1003.11 and R1003.12)
Multiple flues (R1003.13)
Flue area (appliance) (R1003.14)
Flue area (masonry fireplace) (R1003.15)
Inlet (R1003.16)
Cleanout opening (R1003.17)
Chimney clearance (R1003.18)
Fireblocking (R1003.19)
Chimney crickets (R1003.20)
FACTORY -BUILT FIREPLACES (R1004)
Listed and labeled (R1004.1)
Installation (R1004.2 - R1004.5)
FACTORY -BUILT CHIMNEYS (R1005)
Listed and labeled (R1005.1)
Installation (R1005.3 and R1005.4)
EXTERIOR AIR SUPPLY (1711006)
Intake size (R1006.2, R1006.4)
ENERGY EFFICIENCY (Chapter 11)
Compliance; information Electrical (N1104)
(N1101.5, N1101.13) Simulated performance (N1105)
Climate zone (Table N1101.7) ERI compliance alternative (N1106)
Building thermal envelope (N1102) Existing buildings (N1107- N1111)
Systems (N1103)
MECHANICAL (Chapters 12-23)
Appliance labeling (M1302, M1303)
Appliance access (M1305, M1401)
Appliance installation (M1307)
Heating and cooling equipment; load calcula-
tions (Chapter 14)
Exhaust systems (Chapter 15)
Duct systems (Chapter 16)
Combustion air (Chapter 17)
Chimney and vent location and terminations
(Chapters 10 and 18)
Special equipment (Chapter 19)
Boilers/water heaters (Chapter20)
Hydronic piping (Chapter2l)
Special piping and storage systems
(Chapter 22)
Solar thermal energy systems (Chapter23)
Penetrations of fire -resistance rated assem-
blies (R302.4, R302.5)
FUEL GAS (Chapter 24)
Application (G2401.1)
Clearances (G2409)
General regulations (G2404)
Electrical and electrical bonding
(G2410, G2411)
Appliance location (G2406)
Pipe sizing (G2413)
Air requirements (G2407)
Piping materials (G2414)
Installation (G2408)
10-
FUEL GAS (cont'd)
Piping installation (G2415 and G2419) Venting (G2425 - G2429)
Piping support (G2418 and G2424) Misc appliances
Valves, controls, connections (G2423, G2430 - G2454)
(G2420, G2421 and G2422)
PLUMBING (Chapters 25-33)
Water service location and depth
(P2603, P2604)
Sanitary and storm sewer location and depth
(P2603, P2604)
Piping support (Table P2605.1)
Listed plastic materials (P2609)
Plumbing fixtures (Chapter27)
Water heater size and location (Chapter28)
Water supply and distribution system -design
and calculations (Chapter29)
Dwelling unit fire sprinkler systems (P2904)
NFPA 13D system (P2904.1)
Temperature rating
(P2904.2.1, P2904.2.2)
Freezing protection (P2904.2.3)
Sprinkler coverage (P2904.2.4)
Piping materials (P2904.3)
Flow rates (P2904.4.1, P2904.4.2)
Water supply capacity (P2904.5.2)
Pipe sizing (P2904.6)
Drain, waste and vent pipe sizing and riser
diagram (P3004, P3005, Chapter3l)
Sumps and ejectors (P3007)
Backwater valves (P3008)
Fixture traps (P3201)
Storm drainage (Chapter 33)
Penetrations of fire -resistance rated assem-
blies (R302.4, R302.5)
ELECTRICAL (Chapters 34-43)
Penetrations of fire -resistance rated assem- Wiring methods (Chapter38)
blies (E3402.2)
Required lighting and receptacle outlets
Listed and labeled materials (E3403) (E3901, E3903)
Service equipment and location
(E3405, E3601, E3606)
Service size and load calculations (E3602)
Available fault current (E3606)
System grounding (E3607)
Ground -fault and arc -fault circuit -interrupter
protection (E3902)
Devices and lighting fixtures (Chapter 40)
Appliance installation (Chapter4l)
Swimming pools (Chapter42)
Required branch circuits (E3703) Class 2 remote -control, signaling and power -
Feeder requirements and load calculations limited circuits (Chapter 43)
(E3704)
MANUFACTURED HOUSING USED AS DWELLINGS (Appendix E)
Provisions adopted (R102.5) Compliance with Appendix E verified
-11-
PASSIVE RADON GAS CONTROLS (Appendix F)
Provisions adopted (R102.5) Compliance with Appendix F verified
PATIO COVERS (Appendix H)
Provisions adopted (R102.5) Compliance with Appendix H verified
PRIVATE SEWAGE DISPOSAL (Appendix 1)
Provisions adopted (R102.5) Compliance with Appendix I verified
EXISTING BUILDINGS AND STRUCTURES (Appendix J)
Provisions adopted (R102.5) Compliance with Appendix J verified
SOUND TRANSMISSION (Appendix K)
Provisions adopted (R102.5) Compliance with Appendix K verified
HOME DAY CARE—R-3 OCCUPANCY (Appendix M)
Provisions adopted (R102.5) Compliance with Appendix M verified
AUTOMATIC VEHICULAR GATES (Appendix O)
Provisions adopted (R102.5) I Compliance with Appendix O verified
SOLAR -READY PROVISIONS (Appendix U)
Provisions adopted (R102.5) Compliance with Appendix U verified
NOTES
_12_