Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
/8/L , o c/ j 7 FILE COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional -Regulation = Residential -Performance -Method-- - - - Project Name: MONROE RESIDENCE Builder Name: TREFELNER CONSTRUCTION Street: MULLER ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number. Owner. CHRIS AND SARAH MONROE Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2813.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Erd Insul, Erderior R=4.1 2573.00 ft' b. Frame - Wood, Adjacent R=11.0 240.00 ft' 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 4 it. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2982.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=22.0 2982.00 ft' 6. Conditioned floor area above grade (112) 2982 b. N/A R= ft2 Conditioned Floor area below grade (ft2) 0 R _ 2 11. Ducts R ft2 7. Windows(245.0 sgft.) Description Area a. Sup: Attic, Rel: Attic, AH: AHU CLST 6 200 a. U-Factor: Dbl, U=0.32 137.00 ft2 SHGC: SHGC=0.19 �� b. U-Factor. Dbl, U=0.35 96.00 ft' 12. Coding systems (9 kBtu/hr Efficiency SHGC: SHGC=0.20 ` a. Central Unit '�A- 46.0 SEER:16.00 c. U-Factor: Dbl, U=0.29 12.00 ft2 <-.19 � SHGC: SHGC=0.21 13. Heating systems �is) B kBtu/hr Efficiency d. U-Factor: NIA ft' a. Electric Strip® Heat OG 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.195 14. Hot water systems 8. Floor Types (2982.0 sgft,) Insulation Area a. Propane Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 2982.00 ft' b. Conservation features EF: 0.590 b. N/A R= ff None c. N/A R= ft- 16. Credits None Glass/Floor Area: 0.082 Total Proposed Modified Loads: 86.46 PASS Total Baseline Loads: 91.11 1 hereby certify that the plans and specifications covered by Review of the plans and S74 this calculation are in compliance with the Florida Energy specifications covered by this O�'SIiE Code. calculation indicates compliance with the Florida Energy Code. F rrnr,'.X'-; •`,;i�•°'ss„ O PREPA13EQ Y Before construction is completed n C DATE: -' this building will be inspected for compliance with Section 553.908 t7 y I hereby certify that this building, as desi ned, is in compliance Florida Statutes. with the Florida Energy Code. I COp WE OWNER/AGE T BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). JAN 8 "019 19 10:13 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 7 ST. Lucie County. PerctllttiRQ_ FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT --Title: MONROE-RESIDENCE-- — —Bedrooms:— _ 4-- _ _ _Address Type: Street Address Building Type: User Conditioned Area: 2982 Lot # — Owner Name: CHRIS AND SARAH MONRO Total Stories: 1 BloddSubdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: TREFELNER CONSTRUCTI Rotate Angle: 0 Street: MULLER ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL , New/EAsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TINY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO—BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2982 30136 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 CABANA 105 1050 No 0 1 Yes Yes Yes 2 BEDROOM 2 180 1800 No 0 1 1 Yes Yes Yes 3 WIC2 36 360 No 0 1 Yes Yes Yes 4 WIC 30 300 No 0 1 No Yes Yes 5 BEDROOM 3 180 1800 No 0 1 1 Yes Yes Yes 6 HALL 24 240 No 0 1 No Yes Yes 7 BATH 3 75 750 -No 0 1 Yes Yes Yes 8 CLST 4 22 220 No 0 1 Yes Yes Yes 9 BEDROOM 4 162 1620 No 0 1 1 Yes Yes Yes 10 HALL 2 24 240 No 0 1 No Yes Yes 11 AHU CLST 12 120 No 0 1 No Yes Yes 12 LAUNDRY RM 95 950 No 0 1 No Yes Yes 13 KITCHEN 264 2640 Yes 0 1 No Yes Yes 14 GREAT ROOM 437 4370 No 0 1 Yes Yes Yes 15 LIVING ROOM 309 3090 No 0 1 Yes Yes Yes 16 M HALL 12 120 No 0 1 No Yes Yes 17 MASTER BEDROO 316 3476 No 0 1 1 Yes Yes Yes 18 M W IC 1 49 490 No 0 1 Yes Yes Yes 19 M W IC 2 108 1080 No 0 1 Yes Yes Yes 20 M TOILET 42 420 No 0 1 Yes Yes Yes 21 M BATH 274 2740 No 0 1 Yes Yes Yes 22 M CLST 11 110 No 0 1 No Yes Yes 1/24/2019 10:13 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 7 -FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES —_-Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 23 DINING ROOM 143 1430 No 0 1 Yes Yes Yes 24 FOYER 72 720 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio CABANA 29 It 0 105 ft2 _ 1 0 0 2 Slab -On -Grade Edge Insulatio BEDROOM 2 13 ft 0 180 ft2 — 1 0 0 3SIab-On-Grade Edge Insulatio WIC 2 6 It 0 36 ft2 _ 1 0 0 4 Slab -On -Grade Edge Insulatio WIC3 1 It 0 30 ft2 — 1 0 0 5SIab-On-Grade Edge Insulatio BEDROOM 3 12 It 0 180 ft2 — 1 0 0 6 Slab -On -Grade Edge Insulatio HALL 1 It 0 24 ft2 — 1 0 0 7 Slab -On -Grade Edge Insulatio BATH 3 51t 0 75 ft2 _ 1 0 0 8 Slab -On -Grade Edge Insulatio CLST 4 2 it 0 22 ft2 — 1 0 0 9 Slab -On -Grade Edge Insulatio BEDROOM 4 12 It 0 162 ft2 _ 1 0 0 10SIab-On-Grade Edge Insulatio HALL 2 1 It 0 24 ft2 — 1 0 0 11SIab-On-Grade Edge Insulatio AHU CLST 1 It 0 12 ft2 — 1 0 0 12SIab-On-Grade Edge Insulatio LAUNDRY RM 1 ft 0 95 ft2 — 1 0 0 13SIab-On-Grade Edge Insulatio KITCHEN 1 It 0 264 ft2 — 1 0 0 14SIab-On-Grade Edge Insulatio GREAT ROOM 42 ft 0 437 ft2 — 1 0 0 15SIab-On-Grade Edge Insulatio LIVING ROOM 10 ft 0 309 ft2 — 1 0 0 16Slab-On-Grade Edge Insulatio M HALL 1 It 0 12 ft- — 1 0 0 17SIab-On-Grade Edge Insulatio MASTER BEDRO 33 It 0 316 ft' — 1 0 0 18SIab-On-Grade Edge Insulatio M W IC 1 7 It 0 49 ft2 — 1 0 0 19SIab-On-Grade Edge Insulatio M WIC 2 5 It 0 108 ft2 — 1 0 0 20SIab-On-Grade Edge Insulatio M TOILET 9 It 0 42 ft2 — 1 0 0 21SIab-On-Grade Edge Insulatio M BATH 46 It 0 274 ft2 _ 1 0 0 22SIab-On-Grade Edge Insulatio M CLST 1 It 0 11 ft2 — 1 0 0 23SIab-On-Grade Edge Insulatio DINING ROOM 15 ft 0 143 ft2 — 1 0 0 24SIab-On-Grade Edge Insulatio FOYER 8 It 0 72 ft2 — 1 0 0 1/24/2019 10:13 AM EnergyGauge® USA Seclion R405.4.1 Compliant Software Page 3 of 7 -FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ROOF - / Roof Gable Roof Solar SA Emilt Emitt Deck Pitch V # Type Materials __ Area P.rea -Color Absor.-Tested- Tested -Insul. (deg)- 1 Hip Metal 3335 ft2 0 ft2 Light 0.6 No 0.9 No 22 26.6 ATTIC / `7 # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2982 It' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Unvented) CABANA 22 Blown 105 ft2 0.1 Wood 2 Under Attic (Unvented) BEDROOM 2 22 Blown 180 ft. 0.1 Wood 3 Under Attic (Unvented) WIC 2 22 Blown 36 ft' 0.1 Wood 4 Under Attic (Unvented) WIC 3 22 Blown 30 ft' 0.1 Wood 5 Under Attic (Unvented) BEDROOM 3 22 Blown 180 ft2 0.1 Wood 6 Under Attic (Unvented) HALL 22 Blown 24 ft' 0.1 Wood 7 Under Attic (Unvented) BATH 3 22 Blown 75 ft2 0.1 Wood 8 Under Attic (Unvented) CLST 4 22 Blown 22 ft2 0.1 Wood 9 Under Attic (Unvented) BEDROOM 4 22 Blown 162 ft2 0.1 Wood _ 10 Under Attic (Unvented) HALL 2 22 Blown 24 ft2 0.1 Wood _ 11 Under Attic (Unvented) AHU CLST 22 Blown 12 ft2 0.1 Wood _ 12 Under Attic (Unvented) LAUNDRY RM 22 Blown 95 W 0.1 Wood _ 13 Under Attic (Unvented) KITCHEN 22 Blown 264 ft2 0.1 Wood _ 14 Under Attic (Unvented) GREAT ROOM 22 Blown 437 ft2 0.1 Wood _ 15 Under Attic (Unvented) LIVING ROOM 22 Blown 309 fY 0.1 Wood _ 16 Under Attic (Unvented) M HALL 22 Blown 12 ft2 0.1 Wood _ 17 Under Attic (Unvented) MASTER BEDRO 22 Blown 316 ft' 0.1 Wood _ 18 Under Attic (Unvented) M WIC 1 22 Blown 49 ft2 0.1 Wood 19 Under Attic (Unvented) M W IC 2 22 Blown 108 ft2 0.1 Wood _ _ 20 Under Attic (Unvented) M TOILET 22 Blown 42 ft2 0.1 Wood _ 21 Under Attic (Unvented) M BATH 22 Blown 274 ft2 0.1 Wood _ 22 Under Attic (Unvented) M CLST 22 Blown 11 ft2 0.1 Wood _ 23 Under Attic (Unvented) DINING ROOM 22 Blown 143 ft2 0.1 Wood 24 Under Attic (Unvented) FOYER 22 Blown 72 112 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 E Exterior Concrete Block - 6R InsuCABANA 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 _ 2 S Exterior Concrete Block - Ext InsuCABANA 4.1 15 0 10 0 150.0 ft2 0 0 0.6 0 _ 3 W Exterior Concrete Block - Ext InsuCABANA 4.1 7 0 10 0 70.0 If 0 0 0.6 0 _ 4 E Exterior Concrete Block - Ext InfiEDROOM 2 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Ext InfiEDROOM 2 4.1 1 0 10 0 10.0 ft2 0 0 0.6 0 1/24/2019 10:13 AM EnergyGauge® USA Section R405A.1 Compliant Software Page 4 of 7 -FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT WALLS - --- Adjacent__ _ Cavity Width Height Sheathing Framing Solar Below - -Space- _ - - - - - In _ _ _ _ 6 E Exterior Concrete Block - Ext Insul WIC 2 4.1 6 0 10 0 60.0 ft' 0 0 0.6 0 _ 7 E Exterior Concrete Block - Ext IndIEDROOM 3 4.1 12 0 10 0 120.0 ft' 0 0 0.6 0 _ 6 E Exterior Concrete Block - Ext Insul BATH 3 4.1 5 0 10 0 50.0 ft' 0 0 0.6 0 _ 9 E Exterior Concrete Block - Ext Insul CLST 4 4.1 2 0 10 0 20.0 ft' 0 0 0.6 0 _ 10 E Exterior Concrete Block - Ext IngffDROOM 4 4.1 12 0 10 0 120.0 ft' 0 0 0.6 0 11 N Garage Frame - Wood BEDROOM 4 11 14 0 10 0 140.0 ft' 0 0.25 0.6 0 _ 12 N Garage Frame - Wood LAUNDRY R 11 10 0 10 0 100.0 ft' 0 0.25 0.6 0 _ 13 S Exterior Concrete Block - Ext InSaREAT ROO 4.1 23 0 10 0 230.0 ft' 0 0 0.6 0 14 W Exterior Concrete Block - Ext In3BREAT ROO 4.1 19 0 10 0 190.0 ft' 0 0 0.6 0 _ 15 S Exterior Concrete Block - Ext IndtIVING ROO 4.1 10 0 10 0 100.0 ft' 0 0 0.6 0 _ 16 S Exterior Concrete Block - Ext In9NWSTER BE 4.1 16 0 11 0 176.0 ft' 0 0 0.6 0 _ 17 W Exterior Concrete Block - Ext InSNMSTER BE 4.1 17 0 11 0 187.0 ft2 0 0 0.6 0 _ 18 W Exterior Concrete Block - Ext InsulM W IC 1 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 _ 19 E Exterior Concrete Block - Ext InsulM W IC 2 4.1 5 0 10 0 50.0 ft' 0 0 0.6 0 _ 20 W Exterior Concrete Block - Ext Instal TOILET 4.1 9 0 10 0 90.0 ft2 0 0 0.6 0 _ 21 N Exterior Concrete Block - Ext InsulM BATH 4.1 19 0 10 0 190.0 ft' 0 0 0.6 0 22 E Exterior Concrete Block - Ext Insults BATH 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 23 W Exterior Concrete Block - Ext InsulM BATH 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 24 N Exterior Concrete Block - Ext InfiNING ROO 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 _ 25 W Exterior Concrete Block - Ext In3DW ING ROO 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 26 N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 E 4 Vinyl Low-E Double Yes 0.32 0.19 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None _ 2 E 7 Vinyl Low-E Double Yes 0.32 0.19 N 15.0 ft' 1 ft 0 in 1 ft 4 in None None _ 3 E 8 Vinyl Low-E Double Yes 0.32 0.19 N 6.0 ft2 1 ft 0 in 1 ft 4 in None None 4 E 10 Vinyl Low-E Double Yes 0.32 0.19 N 15.0 ft' 1 ft 0 in 1 ft 4 in None None _ 5 S 13 Vinyl Low-E Double Yes 0.32 0.19 N 30.0 ft2 1 ft 0 in 1 ft 4 in None None _ 6 W 14 Vinyl Low-E Double Yes 0.35 0.2 N 96.0 fl2 1 ft 0 in 1 ft 4 in None None _ 7 W 17 Vinyl Low-E Double Yes 0.32 0.19 N 20.0 ft' 1 ft 0 in 1 ft 4 in None None _ 8 W 20 Vinyl Low-E Double Yes 0.32 0.19 N 6.0 ft2 1 ft 0 in 1 ft 4 in None None _ 9 N 21 Vinyl Low-E Double Yes 0.29 0.21 N 12.0 ft2 1 ft 0 in 1 ft 4 in None None 10 N 24 Vinyl Low-E Double Yes 0.32 0.19 N 30.0 ft2 1 ft 0 in 1 ft 4 in None None 11241201910:13 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page of FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE _# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 552 ft552 R' 24 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000449 3515.9 193.02 363 .3493 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 46 kBtu/hr 1380 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Garage 0.59 1 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS V # Supply — Location R-Value Area — Return — Air CFM 25 CFM25 Locaton Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 200 ft' Attic 20 ft' Default Leakage AHU CLST (Default) (Default) 1 1 1/24/2019 10:13 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 7 A i 10 O d d W CD 3 O 0 d V O _ _ p0 p0 _ g <m(pQc) O O �=H. m b f0 f0 C p »> f0 0 0 0 O N O N 0 N 0 N 0 0 l� O O N O N O 0 O N O N 0 N 0 lU. 0 (� 0 N� 0 N O N O 0 N 0� 1� _ C _ C ^� N d 5 d R d d W N d 5 N d 5 d N d N 01 N d d d d d d -Ni. d d d d c < m m H m � W m W OD W m 'm W W W W W m W W W m m S Q Q U V O' O' V. V Q Q O' O' V V V v d c �1 d (JIf N N N N N d N d N N N N N N N y N y N N I`1 N N N N d N N N N N (/ Z. 4 N N N N y d y N �r N N N N J a a a n n n n a a N a a a a a n n n n a a a a n S x x 3 x 3 x x x S 3 S x x S x 3 x = m � 33 33 99 33 N Z am o Qo-o rn mm mm OVW J dm� O N mm WN mm OW WVd N S 3 S x x x 3 x x w x 3u` C aaa mm mm om om W 10 mm mm WV WV A ��� T III mm mm Om Om m S (/i mm mm VV VV C J (n mm mN mm mW m ScCJJ mm mm W Wm mm mW WW T C m mm mm O O O O O O O O O O O O O O O O O O O O O O O O f.J 41 fJ W W W W fJ W W Lu W W W fu 4f lJ 41 (.J 4l W f.J (J fJ f0m0 O 0 mm mm VV VV m J Wm Wm WW mm x 40 V0v mm WW mm WW Vm WO Vm WO O o Z W r C) m m 3 3 A 3 Z � m Z O O D O 2 O i0 C D 0 r0- D= m 000 { r D 0 Oo D 2 A 0 0 O _� O _� O O y m mm mm V W V W rr- _ r' ZD mm WW WO WO O A i r N A w u' f„ 9 O N m O O Z A i K Q K 9 A W N777 0 mm WW mm mW Vm Wo VW Wo ZZZ « g mm mm wo mo N 000 88S N 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 --AIR-BARRIER AND INSULATION -INSPECTION COMPONENT CRITERIA Project Name: MONROE RESIDENCE Builder Name: TREFELNER CONSTRUCTION Street MULLER ROAD permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: CHRIS AND SARAH MONROE Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints In the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures Installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air light and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and Wring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electricallphone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -Floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 1/24/2019 10:13 AM EnergyGauge@ USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location R insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 46.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2982 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.330 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.195 c) Area 7c. 245.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) Bb. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity 34.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF c) Gas fired, LPG EF 0.59 d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRecO/ g) Other 110131. 11.0 110132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 22.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit 0 Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: / Date: 41 Address of New Home: MULLER ROAD City/FL Zip: FORT PIERCE. FL 1/24/201910:13:35 AM EnergyGaugeO USA 6.0.02- FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 1 of 1 roSummary /g/y_ Job: P y wrightsoft i ry FILE COPY Date: Nov 26, 2018 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Favc 772466-6796 Email: QUICKCALCS AOL.COM Project Information For. MULLEREROAD FORTH ERCELFL R CONSTRUCTION Notes: Weather. Winter Design Conditions Outside db Inside db Design TO Fort Pierce, FL, US Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TO Daily range Relative humidity Moisture difference Heating Summary Structure 28863 Btuh Ducts 8938 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 37800 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heatingg Cooling Area (ft2) 2982 2982 Volume (W) 30136 30136 Airchanges/hour 0.32 0.16 Equiv. AVF (cfm) 161 80 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Calculations 100 EFF 10.6 kW 36094 Btuh 21 OF 1533 cfm 0,041 cfm/Btuh 1.00 in H2O to 90 OF 75 OF 15 OF M 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 22723 Btuh Ducts 12952 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data in Rate/swing multiplier Equipment load 0.95 33891 Btuh sensible Latent Cooling Equipment Load Sizing Structure 3357 Btuh Ducts 3545 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 6902 Btuh Equipment Total Load (Sen+Lat) 40793 Btuh , Req. total capacity at 0.70 SHR 4.0 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TTR6049J1 Coil TEM6AOC42H41++TDR AHRI ref 8676063 Efficiency 13.0 EER, 16 SEER Sensible cooling 32200 Btuh Latent cooling 13800 Btuh Total cooling 46000 Btuh Actual air flow 1533 cfm Air flow factor 0.043 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.84 em ` o 7 /q _ wrYghisoF!' r 1 r ' 2016-No�27 70:e 8 I •'*"" "•^—•y-• RlghiSuile® Uniuxrsa12018 78.0.37 R8U08707 A ♦ ��. IIJ' Page '4CCl`- EADocumnets\Wrightsoft HVAC\MONROE RESIDENCE.mp Cale = MJ8 Front Door Faces: + wrightsoftr Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Nov 26, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire House 254.0 ft 10.1 ft 2982.0 ft' CABANA 29.0 ft 10.0 ft heat/cool 15.0 x 7.0 ft 105.0 ft- Ty Construction number U-value (BtuWft;°F) Or HTM (Btut✓ft') Area (ft.) or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Ccol Gross N/P/S Heat Cool 6 11 _. 1t� I--G 13AAocs..._ _.._ 2 glazing, clr low-e 2glazing,_qIr love 13A-4ocs 2 glazing, clr Im-e 2 alazina _clr lower _ 13A-0ocs - 13AAocs 2 glazing, clr lower 2 glazing, clr laves 2 alazim. clr lave i6ASOmd - - 22A-lph__ . _. _ 0.143 0,290 0.320 6.143 0.320 0.320 "---0.143 ___0.320 0.143 0.320 0.320 �0.350 _0.032 n in n _ a_ a a s- _,a_. w w w w �_ - --4.00 8.12 _ 8_96 4.OD 8.96 8.96 - 4.00 __-8.96 4.00 8.96 8.96 9.80 __ 0.90 _ 38.02 _ _ 219 8.75 8.78 _2.18 23.06 23.06 2.19 __ 8.78 2.19 23.06 23.06 24.47 '_224 0.00 � 400 12 30 ____750 6 45 - --656 _ _30 767 6 20 96 ^2982 2982 _ � 958 0 __ 0 699 0 _ 0 626 ___30 645 0 0 _ 0 - 2982 254 _ 1433 97 _ _ 269 2799 54 _ _ _ 403 2507 __269 2583 54 179 941 __ 2672 9658 783 105 264 -1 s29 138 1038 ----1370 v 264 1411 138 461 _ 2349 -_6680 0 - - -0--0 0 0 - -- -70 0 0 - - �160 _0 70 0 0 0 -_705 105 0 0 ^ -- --70 0 0 - - 150 _-0 70 0 0 _ 0 ,_- 165 29 --- --0 0 _0 280 0 _ _ 0 -601 - ,.__0 280 0 0 _ _ 0 _ _94 1103 -- -0 0 0 153 0 0 ----328 -_ __0 153 0 0 _ _ 0 __235 0 T �-CC Y-=(' - �2.glazing„clr,loww-e_. Vt/ L��-(GG, .C_�, F _ _ i _358 6 c)AED excursion 618 .36 Envelope Ims/gain 23917 17M 2358 834 12 a) Infiltration b) Room ventilation 4946 0 1325 0 557 0 149 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 4250 0 0 0 Subtotal (lines 6to 13) 288M 22723 2915 983 14 15 Less eMemal load Less transfer Redistribution Subtotal Duct leads 31% 57% 0 0 0 28863 8938 0 0 0 22723 12952 31% 57% 0 0 0 2915 903 0 0 0 983 560 Total room load Air required (cfm) 378M 1533 35676 1533 3818 155 1544 58 Calculations approved bvACCA to meet all recuirements of Manual J 8th Ed A- wr79hCso_R- 2018-Nov-27 10:39:38 RightSuite4D Universal 2018 18.0.31 RSUD8101 Page 1 EADocumnelslWrlghtsaft HVACWONROE RESIDENCE.rup Cale = MJ8 Front Door faces: N wrightsoft° Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: DUICKCALCS@AOL.COM Job: Date: Nov 26, 2018 By: i 2 3 4 5 Room name E-Vosed wall Room height Room dimensions Room area BEDROOM 2 13.0 ft 10.0 ft heat/cool 15.0 x 120 If 180.0 ft' WIC 2 6.0 ft 10.0 ft heat(cool 6.0 x 6.0 ft 36.0 W Ty Construction number 1-1-value (Btuh/fti°F) Or HTM (Btuh/ft') Area (fe) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Stuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 (-G 1344ocs - _ ___ - 2 glazing, Gr lowe 2 glazing. Gr IovLe_ 13AAccs 2 glazing, cir lowe 2 elazine. cir- lowe 13AAccs.. _. 2 glazing, clr lorve- l3AAocs 2 glazing, cir lave 2 glazing, cir lave 2 glazino. clr lowe 16A30md -- 22A-tph __ __.0.143 0.290 0.320 0.143 0.320 0.320 0.143 _0.320 0.143 0.320 0.320 0.350 �=.032 1.358 _. n n _n a a a 'a _s_ w w w w - -. 4:00 8.12 _ 8;96 4.00 8.96 8.96 4.00 _ 8.96 4.00 8.96 8.96 9.80 _0.90 38.02 2.19--- 8.75 8.78 2.19 23.06 23.06 219 ___8.78 2.19 23.06 23.06 24.47 __,2.24 0.00 .0 0 0 _- 0 0 0 _ _--- .0 0 0 - _ 0 0 0 _ -0-- 0 0 _._ _-O 0 0 0 0 0 ,_ __ 0 0 p _ 120 0 15 - -- 0 0 _ 105 0 0 _ -.0 0 _ 420 0 134 ! _ 0 0 230 0 346 -- - 0 _._0 22 0 0 0 60 0 0 ---.0 0 60 0 0 ---_-0 ___0 0 0 0 __ 0 _ _36 �6 240 0 0 --0 0 131 0 0 --. __0 __0 0 0 0 0 _,=81 0 . 10 0 0 0 _780 180 10 0 0 0 40 0 0 0 �„_161 494 0 0 0 0 .,__ 36 36 0 0 0 0 '�.„32 228 ,C_- F =180 13 403 0 6 c)AEDe ursion -12 -9 Erwelope loss/gain 1250 988 501 203 12 a) hfiltralion b) R xrn ventilation 250 0 67 01 115 0 31 0 13 Intend gains: Occupants @ 230 Applianceslother 0 0 350 0 0 0 Subtotal (lines 6to 13) 1500 1405 616 234 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 31% 57% 0 0 4 1505 466 0 0 10 1415 807 31% 570/6 0 0 0 616 191 0 0 0 234 134 Total room load Air required (cfm) 1971 80 2222 96 807 33 368 16 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed -FLH wrY9htsoR- 2018-Nov-2710:39:38 A& RightSuite® Universal 2018 18.0.31 RSU08101 Page 2 EADocumnets\Wrighlsoft WAC\MONROE RESIDENCE.rup Cale =MJ8 Front Door faces: N wrightsoft, Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@JIOL.COM Job: Date: Nov 26, 2018 By: 1 2 3 4 5 Room name E1posed wall Room height Room dimensions Room area WIC 3 0 ft 10.0 ft heat/cool 5.0 x 6.0 It 30.0 ft2 BEDROOM 3 12.0 ft 10.0 ft heaticool 15.0 x 12.0 it 180.0 ft2 Ty Construction number U-value (Btuh1ftk'F) Or HTM (Bluh/ft2) Area III or perimeter (ft) Load (Bluh) Area a perimeter (it) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 11 Vjl ILr 13A4&Es 2 glazing, clr low-e 2 glazing, dr loa-e_ 13A4ocs 2 glazing, clr lower 2 alazina. clr Iowa_ 2 glazing,.ciclow�,e_. 13A4ocs 2 glazing, clr low a 2 glazing, clr Im-e 2 ❑lazing, clr lowe. _-0.350 16A-30md 22A_tph .__ 0.143 0.290 _ 0.320 0.143 0.320 __ 0.320 --0.143 _0.320 0.143 0.320 0.320 0.032 ^LM.8 n___-_4.00 In n a a a s- -s_ w w w w -_ - 8.96 --� 4.00 8.96 8.96 4.00 ___ 8.96 ADD 6.96 8.96 9.80 _ 0.90 38.02 __219____.0_ 8.75 8.78 -- -219 23.06 --- 23.06 2.19 _8.78 219 23.06 23.06 24.47 _= 2.24 _.0.00 0 0 0 0 0 ---0 __ 0 0 0 0 _0 _.__30 30 _ 0 0 0 -�� 0 0 0 ---0 __-0 0 0 0 _00 V 30 ---0 00 0 0 ---�0 0 0 __0 0 0 0 __.,. 27 0 0 0 ---0 0 0 -0 __._0 _0 0 0 0 0 _ _67 0 0__0__ 0 0__ -- 120 0 15 _. _. _._00 --0 0 0 0 _ 0___ � I 180 0 0 105 0 0 0 ___0 0 0 420 0 134 ._- -0 _. __0 0 0 0 _.__. 0___0 _�161 456 ..0 0 0 230 0 346 � 0 __0 0 0 0 .__ 403 -----o -f yl I�-CG 44yy .13A4obs t 0 0 0 0 _- _ 12 F__ 6 c)AED excursion -2 -12 Envelope loss/gain 27 65 1172 967 12 a) Infiltration b) Room ventilation 0 0 0 0 231 0 62 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 1 350 Subtotal Qines 6to 13) 27 65 1403 1379 14 15 Less e)demal lead Less transfer Redistribution Subtotal Duct loads 31 % 57% 0 0 6 33 10 0 0 16 80 46 31 % 57% 0 0 4 1407 436 0 0 10 1389 792 Total room load Pdr required(cfm) 44 2 126 5 1843 75 2181 94 Calculations approved byACCA to meet all reouirements of Manual J 8th Ed 2018-Nov 27 10:39:38 ACC G ' ^" RightSulle® Uniwmal 2018 18.0.31 RSU08101 Page 3 E:\Documnets\WdghtsOBHVAC\MONROERESIDENCE.wp CaIc=MJ8 Front Doorfaces: N F�+wrightsoft' Right-M) Worksheet Job: Entire House Date: Nov26,2018 By: QUICK CALCS, INC. 317 STLUCIE LANE, FORTMERCE, FL 34946 Phone: 772-066-6799 Fax 772466-6796 Email: OUICKCALCSa@AOL.COM 1 2 3 4 5 Room name E4=ed wall Room height Room dimensions Room area HALL 0 ft 10.0 ft heat/cool 4.0 x 6.0 ft 24.0 W BATH 3 5.0 ft 10.0 ft heat/cool 15.0 x 5.0 ft 75.0 f 2 Ty Construction number U-value (BtuIVfR'F) Or HTM (Bluh/fP) Area (ft2) or perimeter (ft) Load (Btuh) Am (ft2 or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 11 y/ 13A4ocs 2 glazing, clr laws 2 glazing, clr low_e 13A-0acs 291azing, clr laws 2 elaziro. clr low-_ 13A-0dcs - cir,low-_ 13A-0ocs 2 glazing, clr low-e 2 glazing, clr low¢ 2 glazing. Gr laves i6AJOmd 22A-tph 0.143 0.290 _ 0.320 n n n_ 4.00 8.12 8.96 -2.19 8.75 &78 _ __ ._0 0 0 i--0 0 0 -_.0.~0 __0 0 0 0 0 _ 0 0 0 ---- 6 0 0 _ _ __.0 0 0 ---0 0 0 -_.-0.-_0.--_0' -0-0-0-0 0 0 ----0 0 0 0 0 0 0 _54 0 0 0 --- 50 6 0 0 0_ - 44 0 �0 0 0 0 0 0 _75 5 0 0 176 54 _0 _-.- 0 --- -0 0 0 _ 96 138 0 --.-0 0 _ �L1f' 0.143 0.320 0.320 ---0.143 _0.320 0.320 0.320 0,320 0.032 0.032 1.358 a a e_ s �s_ w w w w - 4.00 8.96 _8.96 4.00 _&96 4.96 8.96 9.80 9.90 0.90 38.02 2.19 23.06 23.06 Z19' _8.78 23.06 3.06 24.47 24.24 =224 0.00 L2glazing, -0-0-0 0 0 0 0 _24 0 0 0 0 0 -'22 0 -0--0 0 0 0 0 ,75 75 _-__0 0 0 0 0 67, 190 0 0 0 0 _768 0 C= F _24 24 6 c)AEl excursion _2 0 Emalope loss/gain 22 52 487 402 12 a) Infiltration b) Room ventilation 0 0 0 0 96 0 26 0 13 Intemzl gains: Occupants Q 230 Appliances/other 0 0 0 0 0 0 Subtotal Qines 6to 13) 22 52 583 428 14 15 Less exlemal load Less transfer Redistribution Subtotal Duct loads 31% 57% 0 0 -22 0 0 0 0 -52 0 0 31% 57% 0 0 113 696 216 0 0 64 492 280 Total room load Air required (cfm) 0 0 0 0 912 37 772 33 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed ,`,'.`aLveet _an-2018-1,1ow27 10:39:38 RighlSuite® Universal 201818.0.31 RSU08101 Page 4 E:\Doeumnets\Wrightsoe HVAC1MONROE RESIDENCE.rup Calc=Wit Front Door faces: N F�I wrightsoft' Right-J@ Worksheet Job: Entire House Date: Nov 26, 2018 By: QUICK CALCS, INC. 317 STLUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Emit: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Eiposed wall Room height Room dimensions Room area CLST 4 2.0 It 10.0 ft heat/cool 11.0 x 2.0 ft 22.0 fP BEDROOM 4 12.0 it 10.0 ft heat/cool 1.0 x 162.0 ft 1620 ft' Ty Construction number U-value (BtufVft'-°F) Or HTM (Btu)Vft2) Area (fe) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 11 ._.__ __ _-____. 13A-0ocs 2 glazing, clr Im-e 2 glazing, it loge_ 13AAws 2 glazing, dr lower 2 olaai clr lcvq � 13AAocs 2 glazing, clr.lovfe_ _ 13Aaocs 2 glazing, clr lows 2 glazing, clr 1 -e 2. glazing. clr laves i6A-30mtl �-- - 22A-tph _-_ 0.143 0.290 0.320 � n n n __- ._ 4.00 8.12 1196 ---2.19 8.75 8.78 2.19 23.06 23.06 2.19 ___.8.78 2 23.06 23.06 24.47 _2.24 0.00 _-"0 0 0 20 0 0 --0 _ _0 0 0 0 0 _-22 22 --`-0 0 --- 0 20 0 0 ---0 __0 0 0 0 0 `_22 2 � 0 0 0 �---- 0 0 -0 44 0 0 -0 _,0 0 0 0 0 _ 49 0 0 0 --0--- 120 0 15 -- 0 ___._0 0 0 0 __ 0 =162 162 .- 0 0 0---0 ---105 0 0 -___. 0 0 20 0 134 ---- 0 0 0 0 0 Vy II----GG ly �-G 0.143 0.320 0.320 -0.143 ,0.320 0.143 0.320 0.320 0.350 =0.032 a a e_ S _s_ w w w w --- 4.00 8.96 8.96 4.00 _596 400 ..19 . 8.96 9.80 -0.90 3&02 80 0 0 230 0 _346 0 -.0 0 0 0 0 =363 0 0 0 �0 .__0 0 0 0 0 ^162 12 0 0 0 0 ,� 20 0 0 0 0 , 145 456 C__ F 1358 _7fi 6 c)AEC excursim -4 -10 Envelope loss/gain 176 89 1156 928 12 a) Infiltration b) Room ventilation 1 38 0 10 0 231 0 62 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 350 Subtotal(lines 6to 13) 214 100 1387 1340 14 15 Less internal load Less transfer Redistribution Subtotal Duct loads 31% 57% 0 0 -214 0 0 0 0 -100 0 0 31% 579/6 0 0 118 1505 466 0 0 T7 1417 808 Total room lead Air required (cfm) 0 0 0 0 1971 80 2224 96 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2018-Now2710:39:38 A&A RMOWaitel9 ESDEUniversal2018 78. alc RJ8 Fr1 Page 5 E:\Documnets\Wrightsoft FiVACIMOMiOE RESIDENCE.rup CaIc=MJB Front Door faces: N �t wrightsoft• Right- J@ Worksheet Date: Entire House Date; Nov 26, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QlJlMCALCS@fOL.COM- 1 2 3 4 5 Room name FKposetl wall Room height Room dimensions Room area HALL 2 O ft 10.0 ft heat/cool 6.0 x 4.0 ft 24.0 ft2 AHU CLST O ft 10.0 ft heat/cool 3.0 x 4.0 ft 12.0 ft- Ty Construction number U-value (Btuh/ftMF) Or HTM (Btuh/ft') Area (fe) or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (aluh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 11 W 13A flocs __ __. _ 2 glazing, clr low-e 2 glazing, clr Iowa- 13AA= 2 glazing, clr low -a 2 glazing. clr lower__ 13AAccs - 2g1azing, clr low-e_ 13A4ocs 2 glazing, clr lowe 2 glazing, clr lowe 2 olazino, clr Iowa 16A�Omd_ - 22A-tph -0343 0.290 0_320 n_ n n --4.00 8.12 8.96 4M 8.96 8.96 _ -4.00 -_8.96 4.90 8.96 9.80 0.90 �0.90 38.02 ' __2.19 8.75 8,78 219 23.06 _ _23.06 2.19 -_8.78 . 23.0606 23.47 24.47 ,�2.24 0.00 ' _. 0 0 0 - 0 0 0 _-__0 _____0. 0 0 0 0 _24 24 _ _ 0 0 _ 0 - -0 0 0 _--_0 0 0 0 0 -0 0 0 ___-0 _._ 0 0 0 0 0 -�22 0 -0 0 0 -___ . 0 0 0 ---0 0 0 0 0 0 �0 0 0 --0 __0 0 0 0 0 _11. _ --0 0 0 II---GG 4j( - L�CC �M-- �G _ r---G C, F --0.143 0.320 0.320 _-0.143 0.320, 0. 0.320 320 0.350 0.032 _-_0.032 1.358 e - a _e_ s s_ w w w w =, - ---0 0 0 _ --0 __^0 0 0 0 _ 0 _ 54 0 ---0 0 0 - _ ___0 0 0 0 0 -_-0 __0 0 0 0 12 '0 0 0 _-_--0 ,._0 0 0 0 0 _-'27 0 0 0 0 0 _ 24 0 0 0 0 _ 0 �12 12 ._._72 0 0 6 c)AEE excursion -2 -1 Envelope loss/gain 22 52 11 26 12 a) infiltration b) Room ventilation 0 0 0 01 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 22 52 11 26 14 1161 Less external load Less transfer Redistribution Subtotal Duct loads 31 % 57% 0 0 -22 0 0 0 0 -52 0 0 31 % 67% 0 0 -11 0 0 0 0 -26 0 0 Total room load Air required (cfm) 0 01 0 01 0 0 0 0 _ Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. c �/- wrighGso.R- 2018-Nov-2710:39:38 RighlSuiteO universal 2018 18.0.31 RSUD8101 Page 6 E:\Decumnels\WdghlsofttWAC\MONROERESIDENCE.mp Calc=MJB Front Doorfaces: N wrightsoft' RighW@ Worksheet Entire House QUICK CALLS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fec 772466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Nov 26, 2018 By: 1 2 3 4 5 Room name Eposed wall Room height Room dimensions Room area LAUNDRYRM 0 It 10.0 ft hest/ccol 1.0 x 95.0 ft 95.0 ft2 KRCHEN 0 ft 10.0 ft heat/cool 1.0 x 264.0 It 264.0 ft2 Ty Construction number U-value (Btuh/ftMF) Or HTM (Stuh/ft2) Area (ft2) or pedmeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat I Cool Gross WKS Heat Cool Gross N/P/S Heat Cad 6 11 V�- _13k4mi _ _ _-__. 2 glazing, clr lower 29la2mg,clrlow-e___T 13A4ocs 2 glazing, clr lave 2 clazino _ r-low a_ 13A4ocs 2 glazing, clr.low e-_, 13A4ocs 2 glazing, clr lone 2 glazing, clr lowe 2 clazino. clr Iowa_ _16A.30md_ 22Mph _ _0.143 0.290 0.320 0.143 0.320 0.320 _-_0.143 __0.320 0.143 0.320 0.320 _0.350 '� _,0.032 _ 1.358 �n n n a a _e s _s_ w w w w = - _--4.00. 8.12 8.96 4.00 8.96 _ _8.96 4.00 ---8.96 . 400 8.0 8.96 9.80 ... _0.90 38.02 __219 8.75 8.78 2.79 23.06 _23.06 2.19 _8.78 219 23.06 19 23.06 24.47 _2.24 ____0__ 0 0 0 0 0 _0 __ 0 0 0 0 0 95 95 __0 0 0 0 0 0 .� __ _0 _ 0 0 00- 0 0 0 ______0 0 0 0 0 0 0 -._ ._0 0 0 0 0 0 __ 213 0 O. 0 _0 0 0 0 __�0 - _-0 0 0 0 0 _264 264 O- 0 0__ 0 0 0 _______0 ____ _0 0 0 0 __ 0 -__264 0 ___0____0 0 00 0 0 0 __ ___0 0 0 0 0 0 ----.0 ___0 0 0 0 0 591 0 -II--GG yl L�--GC t� - --o -0 0 0 0 0 ` _95 0 0 0 0 0 �85 0 0 0 0 __ _ 0_ _237 0 C_ F _0.00 _ 6 c)AE1 excursion -15 -56 Envelope loss/gain 1 185 198 237 535 12 a) Infiltration b) Room verlfila0on 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 200 0 0 1000 Subtotal (ling 6 to 13) a5 398 237 1535 14 15 Less external load Less transfer Redistribution Subtotal Dud loads 31 % 67% 1 0 0 8 93 29 0 0 20 418 238 31% 57% 0 0 7 244 75 0 0 17 1553 885 Total room load Air required (cfm) 122 5 w 28 319 13 24W 105 Calculations approved byACCA to meet all requirements of Manual J 8th Ed - w��g~.t``�H 2O18-%o 2710:39:38 ,` kMONRORight-SuE ESID NCE.nal 81 Calc RJ8 Front Page E:\Documnels\Wrightsoft HVAC\MONROE RESIDENCE.rup CaIc=MJB Front Door faces: N �+wrightsoft• RighW@ Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466 6799 Fax 772466-6796 Emil: QUICKCALCS@AOL.COM Job: Date: Nov 26, 2018 By: 1 2 3 4 5 Room name Bposed wall Room height Room dimensions Room area GREAT ROOM 42.0 ft 10.0 It heat/cool 23.0 x 19.0 It 437.0 W LMNG ROOM 10.0 It 10.0 ft heaUcool 1.0 x 309.0 It 309.0 ft2 Ty Construction number U-value (BIUVIl -°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) a perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W 4---G 1344ocs - - - - 2 glazing, clr lcw-e 2 glazing,clr lowe___ 13A-0ocs 2 glazing, clr Iowa low-e ____ 13A-0ocs 2 glazing„clr,lm s _ 13A4ocs 2 glazing, clr Iowa 2 glazing, clr Iowa 2 clazinq, clr lower 16AJOmd__ 22A-lph _ - 0.143 0,290 _-__0.320 0.143 0.320 0.320 -0.143 _0.320 0.143 0.320 0.320 _ 0.350 _0.032 - n n n a a e__8.96 s_ _s_ w w w _w - 4.00 8.12 ___ 8.96 4.00 8.96 4.00 _8.96 4.00 &96 8.95 9.80 0.90 3&02 239 8.75 __ 8-18 219 23.06 23.06 2.19 _8.78 2.19 23.06 23.06 24.47 __224 0.00 - -- -0 0 0 --0____0_-___0 0 ,_ 0 ' 230 „_,.__30 190 0 0 _ 96 - 437 437 - - 0 0 0. 0 0 " - __.30 94 0 0 0 __437 42 -- - - 0 0 0 0 _ 0 _269 376 0 0 941 _ ,392 1597 - --0 0 0 0 0 0__. _a264 206 0 0 2349 ,-__-979 - -_- _ 0 - - - -0 0 0 -_0 0 __. _0 0 0 0 0 0____0 0 _. ___ 0. 100 -_.___ 0 0 0 0 0 �_ ,309 10 0 0 0 0 _-__ -0 400 _ 0 0 0 __-__0 0 __0 __ 219 _.__0. 0 0 0 0 ___892 0 ._�^-G y/ IL�C __.291azinq.clr yV�/r ! =^- Vt/ 0 0 0 _ 0 _ _309 __309 -0. 0 0 0 0 277 380 _ ___ _ C_ F 1.358 _ 61 c)AED muision 839 51 Envelope loss/gain 4375 5073 1058 860 12 a) Infiltration b) Room ventilation 807 0 216 0 192 0 51 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 500 Subtotal Omes 6 to 13) 5183 5289 1250 1411 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 31% 57% 0 0 6 5189 1607 0 0 16 5305 =4 31% 57% 0 0 5 1255 389 0 0 13 1424 812 Total room load Air required (cfm) 6796 276 8329 358 16" 67 2236 96 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed - wrigFrtso_it- 2018-Nov2710:39:38 1' Lk RlghlSuite® Uniwmal 201818.0.31 RSU08101 Page 8 E:1DocumnelslWr,ghtsoft HVACIMONROE RESIDENCE.mp Cale =MJ8 Front Door faces: N wrightsoft, Right-J@ Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS& L.COM Job: Date: Nov 26, 2018 By: 1 2 3 4 5 Room name F)posed wall Room height Room dimensions Room area M HALL 0 It 10.0 it heat/cool 3.0 x 4.0 It 12.0 ft2 MASTER BEDROOM 33.0 It 11.0 It heat/cool 1.0 x 316.0 It 316.0 ft2 Ty I Construction number U-ralue (BtuWfti'F) Or HTM (BtuWft2) Area (ft'j or perimeter (ft) Load (Btuh) Area (ft2) a perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Grass N/P/S Heat Cool 6 Wj' �G 13A46cs 2 glazing, clr low-e 2glazing,,,Grlayc - 0.143 0.290 '- 0_320 n n n 4.00 8.12 __8_96 2.19 8.75 8.78 0 0 0---0- 0 0 0 0 0 0 0 0 -0 0 0 0 0 0_ 0 0 0 0 0 0 �G 11 4y 13A4ws 2 glazing, clr low-e 2 alazim. clr low-e _ 13A4ocs 2,glazing, clrlow e_ 13A4ms 2 glazing, or lowe 2 glazing, cir lowc 2 olazino. clr lowe_ 116A-30md 22A4ph 0.143 0.320 0.320 -0.943 __0.320 0.143 0.320 0.320 _0.350 a a _e s _s_ w w w w_ = 4.00 8.96 _ 8.96 4.00 _8.96 4.00 8.96 8.96 9.801 _0.90 38.02 _ 2.19 23.06 23.06 "- 2.19 _8.78 219 23.06 23.06 24.47 --224 0.00 - 0 0 0 0 0 0 _ 0 0 0 ---0 .___0 0 0 0 0 - 0 0 0 ~'0 ____0 0 0 0 0 =_27 0 -- 0 0 _ 0 176 -._-0 187 0 20 0 __316 316 0 0 0 176 0 167 0 0 0 _316 33 0 0 __ 0 705 0 0 0 0 -- -385 _._0 365 0 461 0 - 708 0 II-�(, v1��!! --G _ -0 0 -0 __0 0 0 0 0_ _ 12 0 0 0 0 0 - 2 12 669 0 179 0 _283 1255 . C_ F =.11 0 _0.032 1.358 - - 6 c)AED excursion -1 119 6Nelope loss/gain 11 26 3091 2038 12 a) Infiltration b) Room ventilation 1 0 0 0 01 698 0 187 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 5XI Subtotal Qines 6to 13) 11 26 3788 2725 14 15 Less eMemal [Dad Less transfer Redistribution Subtotal Duct loads 31 % 57% 0 0 -11 0 0 0 0 -26 0 0 31 % 57% 0 0 6 3794 1176 0 0 14 2739 1561 Total room load Air required (cm) 0 0 0 0 1 4969 202 4300 185 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2018-Nov2710:39:38 A RightSuileO Unmrsal 2018 18.0.31 RSU08101 Page 9 E:\DocumetslWdghtsoftWAC\MONROERESIDENCE.mp Calc=MJ8 Front Doorfaces: N wrightsoftr RighW@ Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: MA66-6799 Fax 772466-6796 EmaiC OUICKCALCS@AOL.COM Job: Date: Nov 26, 2018 By: 1 2 3 4 5 Room name Eipmed wall Room height Room dimensions Room area M WIC 1 7.0 It 10.0 it heat/cool 7.0 x 7.0 It 49.0 f 2 M W IC 2 5.0 it 10.0 If heat/cool 1.0 x 108.0 It 10&0 ft2 Ty Construction number U-value (BtuWft2-°F) Or HTM (Btuh/f 2) Area (W) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (it) Load (Btuh) Heal I Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 8 W I--G 13A-0ocs 2glazing, cir lower 291azing, clr lower 0.143 0290 0_320 n n n_ 4.00 8.12 8,96 219 8.75 &78 0 0 0 -0--0- 0 0 0 0 -0--- 0 0 0 0 0 --- `0 0 0_ -----D 0 0 -`---'0 0 0 --G W 13A-4ocs 2 glazing, clr low-e 2 glazina, clr low a 13AAccs -� 2 glazing, clr lower_ 13A-4ocs 2 glazing, clr Iow-e 2glazing, cIr love 2 glazing. clr low e _ 16A30md _ 22A--loh 0.143 0.320 0.320 �0.143 _0.320 0.143 0.320 0.320 _ 0.350 0.032 a a a ._6 _s_ w w w w _ - 4.00 8.96 8.96 _ -4.00 --8.96 4.00 8.96 8.95 9.80 _0.90 38.02 2.f9 23.06 23.06 219 �8.78 2.19 23.06 23.06 24.47 ,2.24 0.00 0 0 0 --0 ----0 70 0 0 0 0 0 0 --0 _0 70 0 0 _ _ 0 �� 49 0 0 0 __ 0 __0 280 0 0 0 0 0 0 _ _-0 0 50 0 0 -._-0-_-_0 --0--0-0 0 0 0 0 �_108 108 50 0 0 0 0 0 ,_ 0 =08 5 200 0 0 -.___0 109 0 0 _ -0 �G 153 0 0 0 0 0 0 ,�_ 0 =97 190 -0 0 0 0 �. 0 _242 0 _ C__ F _ 49 49 44 266 _110 0 1.358 7 __ 6 c)AED excursion -11 -13 Envelope loss/gain 1590 252 487 338 12 a) Infiltration b) Room ventilation 135 0 36 0 96 0 26 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (fines 6to 13) 725 288 5S3 364 14 15 Less external lead Less transfer Redistribution Subtotal Duct loads 31 % 571% 0 0 1 726 225 0 0 3 292 166 31 % 570/. 0 0 2 586 181 0 0 6 369 211 Total room load Air required (cfm) 951 39 456 20 767 31 580 25 Calculations approved byACCA to meet all requirements of Manual J 8th Ed _ # wr19h+�.ff-t- 2018-Wo 2710:39:38 RighlSuite® Uniwmal 201818.0.31 RSU08101 Page 10 EADocumnetslWrighlsoft WACIMONROE RESIDENCE.rup Cale = MJ8 Front Door faces: N Fkl wrightsoft' RightJ@ Worksheet Entire House QUICK CALCS, INC. Job: Date: Nov 26, 2018 By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fan 772-466-6796 Emall: OUICKCALCS@AOL.COM - - - -- -- 1 3 4 5 Room name R mheightad ) Room dimensions Room area M TOILET 10.0 ft 90 ft heat/ccol 1.0 x 42.0 ft 42.0 ft- M BATH 10.0 ft 46'0 It heat/cool 1.0 x 274.0 ft 274.0 W Ty Construction number u-value (BUMMF) Or HTM (Btuh/ft') Area (ft'j or perimeter (ft) Load (Btuh) Area (ft9 or perimeter (ft) Load (Btuh) Heai Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool fi 11 2 glazing, clr laws 2 glazing, clr lower 13A-0ocs 2 glazing, clr )owe 2alazino, clr laws _ 13A<Wcs 2.glazing, clrlowe_ 13A-0ocs 2 glazing, clr low¢ 2 glazing, clr low-e 2 olazim. clr low¢ ,.16A30md -- 22A-tph -0343 0.290 0.320 "n n n 4:00 8.12 8.96 - 2.19 8.75 8.78 _ - ..0 0 0 0 0 0 ----0 0 _._0 0 0 --0 0 0 --`.0 0 0_ __ - .190 12 0 -. -178 0 0 " '713 97 0 .- - _384 105 0 �-G Vy �G �-G y/ L-a 0.143 0.320 0.320 ---0.143 _0.320 0.143 0.320 0.320 0.350 =0.032 1.358 a a e -s _s- w w w _w -� 4.00 8.96 _ 8.96 4.00 _8.96 4.00 8.96 8.96 9.80 _0.90 38,02 2.19 23.06 _ _23.06 2.19 -878 219 23.06 23.06 24.47 _2 0.00 0 0 0 --0- __0 84 0 0 0 _24 = 42 9 0 0 0 -0 - --0 336 54 0 _ 0 _= 38 342 0 0 0 --0 __0 184 138 0 0 -=94 0 140 0 0 --_-0 _ ,0 130 0 0 _ 0 �274 _ 274 140 0 0 561 0 _0 0 306 0 _0 T 0 -��0 __0 130 0 0 0 __274 _ 46 90 6 0 0 _, 42 42 _0. 521 0 0 0 `=246 1749 _0 284 0 0 0 �614 0 _ C_ F 6 c)AED excursion 47 .68 ErrMope loss/gain 770 463 3886 1631 12 a) Infiltration b) Room ventilation 10 173 46 0 884 0 237 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 1 0 0 Subtotal (lines 6 to 13) 943 509 4770 1868 14 15 Less e1¢emal load Less transfer Redistribution Subtotal Dud loads 31 % 57% 0 0 4 947 293 0 0 9 519 296 31 % 570/6 0 0 2 4772 1478 0 0 5 1873 1067 Total room load Air required (cfm) 1240 50 815 35 6250 254 2940 126 Calculations approved byACCA to meet all requirements of Manual J 8th Ed 2018-Nov2710:39.38 \MONROE RESIDE CE.ru 18. alc RJ8 Front Page 11 E:\Documnets\Wrighlsoft HVAC\MONROE RESIDENCE.mp Calc = MJB Front Door faces: N wrightsoft' Righttil@ Worksheet Job: Entire House Date: Nov 26, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@f(5L.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area M CLST 0 ft 10.0 it heat/cod 1.0 x 11.0 ft 11.0 fP DINING ROOM 15.0 ft 10.0 ft heat/cool 13.0 x 11.0 It 143.0 fP Ty Construction number U-value (BtuWftMF) Or HTM (Btuhlft° Area OF) or perimeter (ft) Load (Btuh) Area (ft°j or perimeter (ft) Load (Bluh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 11 I—G 13A46cs 2 glazing, Ur low- 2_o s glazing, dr low-e_ 13AI 2 glazing, clr low-e 2 olazino _clr love 13A4ors - - 2 glazing, cirlowce_ 13A4ocs 2 glazing, clr low¢ 2 glazing, clr lave 2 glazirg.clr laws - 16A30md -- 22A-tph 0.143 0.290 0.320 n n n 4.00 8.12 ._ . 2A9 8.75 8.78 _ _ 0 0 _0 0 0 0 -. ��-0 __0 0 0 0 0 _. 0 0 _ 0 0 0 0 -0 — .0 0 _ 0 0 0 0 -- ` --0 __0 0 0 0 0 _10 0 -0 0 _ 0 0' 0 0 ---0-- __0 0 0 0 0 _25 0 _ -130 0 30 -. --- 100 0 0 400 0 269 219 0 264 0 0 0 - ----0 __0 44 0 0 0 - 820 0 II��--GGGG 4y 0.143 0.320 0.320 --0.143 0.320 0. 0.320320 0.320 0.350 -=0.032 1.358 _ a a a s - _s_ w w w w_ _ _ _8_96 4A0 896 8.96 .-4.00 __8.96 4..0 8.9696 8.96 9.80 _„0,90 38.02 J 219 23.06 23.06 -- 219 _8.78 23.6 06 23.Ofi _ 24.47 224 0.00 0-0-0 0 0 --0 __ __-0 20 0 0 0 = 143 143 0 0 '- —0 ___._0 20 0 0 0 _ 143 15 0 _0 -- -- 0 0 80 0 0 0 __128 570 II---GG 4Y _ .C_ F _0 0 0 0 0 _ 11 0 �_11 11 6 c)AED excursion -1 32 Fmelope loss/gain 10 24 1448 814 12 a) Infiltration b) Room ventilation 0 0 0 0 288 0 77 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 10 24 1736 891 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 31% 67% 0 0 -10 0 0 0 0 -24 0 0 31% 57% 0 0 0 17W 53 8 0 0 0 891 508 Total mom load Alr required (rim) 0 0 0 0 2274 92 1399 60 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrlghtsoeft- 2018-Now2710:39:38 A&A RighlSuile® Uruwrsal 201818.0.31 RSUG8101 Page 12 E:1Documnets\Wdghtsoft WAC\MONROE RESIDENCE.mp Calc = MJ8 Front Door faces: N i#F wrightsoft° Right-M) Worksheet Job: Entire House Date: Nov 26, 2016 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone. 772466-6799 Fax 77246rs6796 Email: QUICKCALCS@Af 6L.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area FOYER 8.0 ft 10.0 ft heat/cool 8.0 x 9.0 ft 72.0 ft' Ty Construction number U-value (Btu)Vftk.F) Or HTM (Btuh/ft2) Area (ft� or perimeter (ft) load (etuil) Ala or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heal Cool 6 11 Vj/ I--G 13A-0acs -- 2 glazing, clr low-e 2 glazing, dr I_ow�_ 13A4ocs 2 glazing, Gr lower 2 olazine clr Iow��_ -13A-0ocs 2 glazing, cfr,low� _ 13A-0ocs 2 glazing, Gr lov-e 2 glazing, clr low-e 2gl-30m c_Ir_lave 16A-30md - 22A-tph - `6.143 0.290 0.320 n n n 4.00 8.12 --239 8.75 ---80 0 0 - 80 0 0 0 0 0 --0 -._0 0 0 0 0 ---72 8 -�- - 320 0 0 175 0 I--G 4y 0.143 0.320 0.320 --0.143 _0.320 0.320 0.320 0.320 0.350 �0.032 a a a --a- -a - w w w w `- _i8.96 4.00 8.96 8.96 4.00 _8.96 4.00 8.96 9.80 8.80 =�0.90 __ 2.19 23.06 23.06 - 2.19 _8.78 3.06 23.06 24.47 24,47 =,224 -� 0 0 0 --_0 --0 0 0 0 0 _72 __0 0 0 0 �0 0 0 0 - - _ - - II-----GG lM L-G 0 0 0 0 0 0 .0 Vy --0 0 0 0 0 T_181- 0 ��Lf(G'' C� F =85 304 1.358 3M 0.00 72 e _ 6 c)AE1 emursion .48 Envelope loss/gain 689 288 12 a) Infiltration b) Room ventilation 154 0 41 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 1000 Subtotal (lines 6to 13) 843 1329 14 15 Less eMemal load Less transfer Redishibution Subtotal Duct loads 31% 57% 0 0 0 843 261 0 0 0 1329 758 Total more load Air required(cfm) 1104 45 2087 90 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed wrigF„fsoR- 2018-14ov2710:39:38 A&C ' ^^ RighlSuite® Universal 201818.0.31 RSU08101 Page 13 EADocumnets\Wrightsoft FMAC\MONROE RESIDENCE.rup Cale = MJ8 Front Door faces: N wrightsofr Duct System Summary Entire House -- QUICK CALCS,INC- 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALC8QAOL.COM For. MONROE RESIDENCE, TREFELNER CONSTRUCTION MULLER ROAD, FORT PIERCE, FL Job: Date: Nov 26, 2018 By: Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 1533 cfm 1533 cfm Total effective length (TEL) 201 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (In) H x W (in) Duct Mall Actual Ln (ft) Fig.Egv Ln (ft) Trunk BATH h 912 37 33 1.000 5.0 Ox0 VIFx 17.6 115.0 sill BEDROOM 2 c 2222 80 96 1.000 7.0 Ox0 VIFx 41.4 155.0 S15 BEDROOM 3 C 2181 75 94 1.000 7.0 OXO VIFx 17.6 115.0 sill BEDROOM 4 c 2224 80 96 1.000 7.0 Ox0 VIFx 7.0 115.0 st3 CABANA h 3818 155 66 1.000 6.0 0x0 VIFx 42.7 155.0 st5 DINING ROOM h 2274 92 60 1.000 6.0 OXO VIFx 12.0 115.0 st3 FOYER c 2087 45 90 1.000 7.0 Ox0 VIFx 36.4 115.0 st2 GREAT ROOM C 2776 92 119 1.000 7.0 OxO VIFx 46.0 155.0 st5 GREAT ROOM -A c 2776 92 119 1.000 7.0 Ox0 VIFx 30.7 135.0 st4 GREAT ROOM-B c 2776 92 119 1.000 7.0 Ox0 VIFx 20.6 115.0 Bill KITCHEN c 2438 13 105 1.000 7.0 Ox0 VIFx 19.0 115.0 Bill LAUNDRY RM c 657 5 28 1.000 5.0 Ox0 VIFx 7.2 115.0 st3 LIVING ROOM Cr 2236 67 96 1.000 7.0 Ox0 VIFx 56.6 135.0 st6 M BATH h 6250 254 126 1.000 7.0 Ox0 VIFx 39.9 115.0 st2 M TOILET h 1240 50 35 1.000 5.0 Ox0 VIFx 44.4 115.0 st2 M wlc 1 h 951 39 20 1,000 5.0 Ox0 VIFx 56.2 135.0 st6 M WIC 2 h 767 31 25 1.000 5.0 Ox0 VIFx 36.4 115.0 st2 MASTER BEDROOM h 2484 101 92 1.000 7.0 Ox0 VIFx 50.5 135.0 st6 MASTER BEDROOM.A h 2484 101 92 1.000 7.0 Ox0 VIFx 53.9 135.0 st6 WIC h 807 33 16 1.000 4.0 Ox0 VIFx 34.1 135.0 st4 WIC c 126 2 5 1.000 4.0 Ox0 VIFx 29.6 135.0 st4 wrightsoft- 2018-Nov-27 10:39:40 �. •.µ• «m-o•aw+ RightSuite® Universal 201818.0.31 RSU08101 Page 1 ACCA E:1DocumnetMiNdghtsoft HVACWONROE RESIDENCE.rup Cale = MJ8 Front Door faces: N Supply Trunk Detail Table -Name— Trunk ---Type Htg —(cfm)— Clg --(cfm)— Design —FR Veloc —(fpm)— Diam --(in)— - H x W —(in) — Duct _ Material _Trunk st5 Peak AVF 327 281 1.000 739 9.0 0 x 0 VinlFlx st4 st4 Peak AVF 453 422 1.000 687 11.0 0 x 0 VinlFlx st1 st1 Peak AVF 670 773 1.000 838 13.0 0 x 0 VinlFlx st6 Peak AVF 307 301 1.000 694 9.0 0 x 0 VinlFlx st2 st2 Peak AVF 687 577 1.000 874 12.0 0 x 0 VinIFIX st3 Peak AVF 177 184 1.000 527 8.0 0 x 0 VinIFix Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1533 1533 0 1 0 0 0 Ox 0 1 VIFx Wrightsoft- ►t RlghtSuite® Universal 201818.0.31 RSU08101 AC01 E9DocumnelslMghlseft HVAC1MONROE RESIDENCE.rup Cale = M.18 Front Door faces: 2018-Noo-27 10:39:40 Page 2