HomeMy WebLinkAboutGENERAC PAPERWORK16/20/22 INCLUDES: • True Power'" Electrical Technology Standby Power Rating Models G007036-1, G007037-1 (Aluminum - Bisque) -16 kW 60 Hz • Two Line LCD Multilingual Digital Model G007035-1 (Aluminum - Bisque) - its kW 60 Hz Evolution'" Controller (English/Spanish/ ST.LUCIE COUNTY Models G007039-1, G007038-1 (Aluminum -Bisque) - 20 kW 60 Hz French/Portuguese) PLAN REVIEW Models G007043-2, G007042-2 (Aluminum - Bisque) - 22 kW 60 Hz • Two Transfer Switch Options Available 100 Amp, 16 Circuit Switch or BLDG: 200 Amp Service Rated Smart Switch. DA�TE��:��/��.p�.,�Ap� See Page 5 for Details. • Electronic Governor EI r56 DATE.1 -4I-10) • Standard Wi-Fi'" Remote Monitoring PLUMB: • System Status & Maintenance Interval LED Indicators DATE: • Sound Attenuated Enclosure MECH: • Flexible Fuel Una Connector DATE: • Direct -To -Dirt Composite Mounting Pad • Natural Gas or LP Gas Operation • 5 Year Umited Warranty • Usted and Labeled by the Southwest Research Institute allowing installation as close as 181(457 mm) to a structure.* *Must be located away from doors, windows, and fresh air intalres and in accordance with local codes. https:llassets.swd.oTrt�lebrarryy/Dimcfory02'sfedPmductsl Conshuctionlndushy/973_DOC 204_13204-01-01 Rev9.pdf FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability Ior when you need it the most. The G-Farce series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Supedor harmonics and sine wave form produce less than 5%Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micra-chip based appliances, such as variable speed HVAC systems. O TEST CRITERIA: V PROTOTYPE TESTED V NEMA MGI-22 EVALUATION V SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY R.l OLISTED � """'E-T—�" ' Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system Is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at .1 %. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service Imow-how for the entire unit from the engine to the smallest electronic component O GENERAC TRANSFER SWITCHES: Lang life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. O MOBILE LINK'" REMOTE MONITORING: FREE with every Guardian Series Home standby generator. Allows you to monitor the status of your generator from anywhere In the _ G E N E R A C "a. {"" s _ world using a smadphone, tablet or PC. Easily access information such as the current F PROMISE �j °"� operating status and maimenance oleos. Connect your account to your authorized service deaterfor last, friendly and proactive service. With Mobile Link, you are taken care of before the next power outage. kW GENERAC' features and benefits Engine • GeneracG-Force design Maximizes engine"breathing"for increased fuel efficiency. Plateau honed cylinderwalls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic Ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubricalion system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low all pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low all. • High temperature shutdown Prevents damage due to overhearing. Generator • Revolving geld Allows fora smaller, lightweight unit that operates 25%more efficlen0y than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to .0 % prevents damaging voltage spikes. • UL2200listed For your safety. Transfer Switch (if applicable) • Fully automatic • NEMA 3R • Remote mounting Transfers your vital electrical loads to the energized source of power. Can be installed inside or outside for maximum flexibility. Mounts near your existing distribution panel for simple, low-cost Installation. Evolution" Controls • Auto/Manual/Off Illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised barons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoinls 65% dropout, 80%pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic govemor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing Installation, as close as 18" away from a building. Installation System • 1 it (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents setting or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life 16/20/22 kW Model Rated Maximum Continuous Power Capacity M Rated Madmum Continuous Power Capacity (NO) Bated Voltage, - -- RatedMzdmum Continuous Load Current-240 Volts (LP/NG) Total Harmonic Dldortion Main line Circuit Breaker Phase . "- Number of Rotor Poles Rated At Frequency Power FacNr BatteryRequirement (not included) Unit Weight ((bAg) Sound output in dB(A) at 23 N (7 m) with generator operating at normal load" Sound output in dB(A) at 23 R(7 m) with ganeratoi In Quiet -Test'" low -speed exercise mode'" GENERA&' specifications G007035.0, G007035-0, G007038-0, 0007039-0 G007042.1, 13007043.1 0007037.0 (16 kW) (20 kM (22 kW) 16,000Watts' 20,000 Watts' 22,000 16,000 Watts- 18,000 Wafts' 19.500 240 240 240 66.6/66.6 83.3/75 91.6/81.3 Less than 5% Less Ron 5% Lass than 5% 70 Amp 100Amp 100Amp 1 1 1 2 2 2 60 Hz 60 Hz Hit 1.0 1.0 1.0 12 Volts, Group 26R 54Q CCA Minimum or Group 35AGM 650 CCA Minimum 406/186 4481203 4661211 48 x 25 x 29/1218 x 638 x 732 66 66 67 58 58 58 Engine Type of Engine GENERAC G-Force 1000 Series Number of Cylinders 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Amangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/Magneto Solid -stale w/Magneto Solid-state w/Magneto Govemor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 Sailer 12Vdc 12Vdc 12 Vdc Oil Capacity Including Filter APpwx 1.9 g111.8 L Approx 1:90.8 L Approx 1.9 gV1.8 L Operating rpm 3,600 3.600 3.600 _ Fuel Consumption -Natural Gas - • Ifyi r (m3/Iu) 12 Load 218 (6.17) 204 (5.78) 228 (6.46) Full Load 309 (8.75), 301 (8.52) 327 (9.26) !!quid Propane - R3/hr (gaVhr) Whit - 12 Load 91.6 (2.52) [9.531 86 (2.37)18.991 92 (2.53) [9.571 - Full Lead 106:8 (894)111.111 129.6 (3.56) [13A8) 142 (3.90) [14.771 Note: Fuel pipe must be shed lur lull load. Required Nel pressure to generator fuel Inlet at all load mages- 3.5-7'water column (7-13 mm mercury) for naluralgo, l0-12°water column (19-22mm mercury), . for UP gas Fm Btu content multiply lP/Ixx 2500 (LP) or ft3Avx 1000 (NG). For Meoaloule cement, multply m3/hrx 93.15 (LP) or m3/hrx37.26 (NG) 2-Uns Plain Ted Multilingual LCD Display Mode BultonsiAuto Manual OD Readyto RuWaintena rce Messages Engine Run flours hidication Pmgmmmable start delay between 2-1500 seconds Utility Voltage Loss/Retum to Utility Adjustable (Brownoul Selling) Future Set Capable Fxemiser/Fixmise Set Error Warning RuNAhrMMSlntenance Logs - Engine Stall Sequence StadeiLock-out Small Battery Charger ChargerFapltiMlssidgAC Warning to Baftery/Baltery Problem Protection and Battery Condition Indication Autom UcVoltage Regulation with Over and Under Voltage Protection Under-Frequency/Overloa nlepper Oveicunent Protection Safety FuseyFpsa Problem Protrokut Automatic Low Oil Pressum/High Oil Temperature Sheldon Dvercrenvowarspeed:(@ 72 Hzyrpm Sense Loss Shutdown With Engine Tempemone Shutdown Intemal FaultMconect Witting Protection Common Ddemal Fault Capability Field Upgmdaole Fimlware Simple our interlace for ease of operation. Automatic Sort on Utility failure.7 day exerdser. SIM with starter control, unit stays on. it utility fails, motor to lead takes place. Stops um'L Power is removed Control and charger still operate. Standard Standard Standard (programmable by dealer only) From 140-171 V/190-216 V Standard 50 Events Each CyclIc cranking: 16 sec on. 7 rest (90 sec madmum duration). Stader carmot re-engage until sec after engine has stopped. Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Standard Automatic Switches non -Service 100 - 400 Amps, Single Phase C @us LISTED — 'COL only applies to non -service rated switches Description Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'" or Nexus"' Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure`, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. Non -service rated (RXSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. _Fwau .� > Viso GENERAC® Smart Transfer Switches Functions All timing and sensing functions originate In the generator controller Utilityvaltagedrop-out......................................................................................................................................................................................................................<65% Timer to generlor start.................................................................................................. 10 second factory set, adjustable between 2-1500 seconds by a qualified dealer' Enginewarm up delay................................................................................................................................................................................................................. 5 seconds Standbyvoltage sensor..................................................................................................................................................................................................65% for 5 seconds utilityvoltage pickup..........................................................................................................................................................................................................:..............>80% Re -transfer time delay...............................................................................................................................................................................................................15 seconds Enginecool -down timer............................................................................................................................................................................................................ 60 seconds Exerciser..............................................................................................................................................................5 or 12 minutes adjustable weekly/6i-weekly/Manthly— The transfer switch can be operated manually without power applied. 'When used in conjunction with units ptiliNng Evolution- controls "Adjustable via the controller Specifications Model RXSC10OA3 RXSW700A3 RXSW75OA3 RXSC20OA3 RXSW200A3 RXSW300A3 RXSC40OA3 RXSW40OA3 Amps 100 100 150 200 200 300 400 400 Voltage 120/240, to 120/240,1e 120/240,1e 120/240, to 120/240,10 120/240, to 120/240,19 120/240, 10 Load Transition Type (Automatic) Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA/UL 3R NEMAAIL 3R NEMANL3R NEMANL 311 NEMA/UL3R NEMA./UL 311 NEMA/UL 311 NEMA/UL 3R UL Rating UUCUL UL UL UUCUL UL UL UUCUL UL Withstand Rating (Amps) 10,000 10,000 22,000 10.000 22,000 22,000 22.000 22,000 Lug Range 1/0-#14 250MCM-#6 600 MCM - #4 or 1/0 - 250 MCM Dimensions Model RXSC1DOA3 IUSWIOOA3 Ii M50A3 RXSG20OA3 RXSW200A3 RXSW300A3 RXSC400A3 Neigh(nJmm) 17.24/437.9 17.241437.9 26.75/679.4 17.24/437.9 26.75/679.4 42.91/1089.9 31.25/793.8 H2 20/508 20/508 30/762 20/508 30262 4811219.2 36A714A IRXSW40OA3H1 Width W1 12.W17.5 12.5/a17.5 10.5266.7 12.5/317.5 10.5266.7 16,69/423.9 19.18/487.2 pnJmm) W2 14.6/370.8 14.61370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.82/554.2 24/609.6 21.821554.2 Depth (nJmm) 7.091160.1 7.091180.1 6.31160.1 7.091180.1 6.3/160.1 10.06255.5 10.06255.5 10.CW55.5 Weight(Ihs7131m) 20/9.07 22.5/1021 39/17.69 20.07 39t17.69 140/63.5 133/60.33 140/63.5 GENERAC Generac Power Systems, Inc. • S45 W29290 HWY..59, Waukesha, Wl53189 • generac.com ® ®2017Generec Pawersystens,lne Aerightsmsersed. Aespwffl a ommsublecttorhmgevAoutmtce. BWNm1000001345M M4/17 16/20/22 W GENERAC available accessories Mader# . Product Description The Wi-FI enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank Mon- 6007005-0 Wi-R LP Fuel Level Monitor Hurling the LP tanks fuel level is an Important step in making sure your generator Is ready to ran during an unexpected powerfailure. Status alerts are available through a free application to notify when your LP tank Is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G0064634 Mobile Link— cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available In the U.S. only. G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Genemc offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact(D). G007101-0 'Battery Pad Warmer The pad warmer rests underthe battery. Recommended for use If the temperature regularly falls below O*F. (Not necessary for use with AGM -style batteries). G007102-0 till Wanner Oil warmer slips directly overthe oil fitter. Recommended for use if the temperature regularly falls below 0°F. G005621.0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load ' Contact Kit you may not need. Not compatible with 50 amp pro -wired switches. Gg07g27-0-Bisque Fascia Base Wrap ICd The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a (Standard on 22 kW) sleek contoured appearance as well as offering protection from rodents and insects by covering therd0ng holes located in the base. If the generator enclosure Is scratched or damaged, it is Important to touch-up the paint to protect from G005703.0-Bisque Paint KB future corrosion. The paint kit includes the necessary paint to property maintain ortouch-up a generator enclosure. ' Go06485.0 Scheduled Maintenance Kit Geneses scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. ' G006873-0 ment Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to Increase its (5 Amps) powermanagement capabilities. It provides add'None[ powermanagement flexibility notfound in any other power management system. ses'rwoevrew dimensions & UPCs Dimensions shown are approAlrele. Refer to IwWlallon mantel for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTA WTIDN PURPOSES N99 W M.Wv,ew Model UPC G007035-0 696471070354 G007036-0 69647107 3361 G007037O6 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 GOO7043-0 696471070439 GENE RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 a generac.com 02017 GMeMC Pmveraysteme, Inc. All rights reserved All specinWians are subleab change without notice. Pan No. 10000000194F W7 Smart Management Modules (SMM) OENERAC° ACCESSORIES C®ga USM Ug6UHIPTIUN Gegerao's Smart Power Management System Is designed to optimize the performance of a standby generator. The system can consist of up to 8 Indlvldual Smart Management Modules (SMM). Unlike other load management systems that depend on another control device, the SMM modules are actually self - aware and operate autonomously. Frequency is the Ws measure of generator engine performance and does not need to factor In Increased ambient temperatures, elevation changes or generator fuel type. The modules monitor the frequency (Hz) of the power being produced by Generac's standby generators and if It falls below a certain threshold, the module will automatically follow a power management algorithm to ensure that the generator Is not overloaded. The modules can beset to a load prioritybetween 1-8 or beset in a Iock oul only mode for loads that Just Simply do not need to run In an outage, therefore reducing the necessary el2e of the generator for a more cost effective solution. SMM SPECIFICATIONS VAC (from true input) .._-..___24eVAC .................. ..... ,_................ ._... .._.... ... .... ............. ....... _....... ......... e.5 ._...._._....__....... ............. I ........ ........................ ....._.....—.......... .....2 F/LlnducaYeAm ............................__. __. ......__... _.......... ._..50 InnGnd RnMrdmne ............__.._..__ _.. Enclosure aa0n......._...._.._,...__..._.............................._.................._. g. .......... . - ........,....................,........._.._..._..........._Yes_...._._..._......_.............._..,....._.__ _._.._................ I MSR Modules 1. Dimensions and UPC o0o SMM Controls (located behind the cover of the module) B C PRiORffY j-- La'06AD�mg 6 DEflERATOR 0 7 A I 0 LOOKOUT TEST DIMLEO LEDOOcLOAD DORNEOM LEDPIASadS=LOAOSRED LED PLOSR SS o SO M LOOKODr LEDPIASa6SO SIDILMDIDOKarIT Lm Drr� R067DDt][EPOB'ER PriotltyDial W Sets module priority. LM WSMIdJ PrMMlead kamoptimUngwhensystemisaperagngWugammoufpower. Test Mon (Q— DLablee anraator oWpW fora spedged gma. ,ten- Provides mania Status With easyvierWDgtWUgh the edMadWaiving Madura located in Ihs tipper dghl wmer W Ifte module. 3z:WQ_ Generae Power Systems, Inc. o S45 W29290 HWY. 59, Waukesha, WI 58189 a generac.com 02m6Geagao POWpfSystems, W. AO dyasreservtd. AS speciflCaUaos aRSOb]eafteWRla9 ealamROW�. Bogota 0L150aC 0$110/tB Site Selection and Preparation Section a Otte Sei�ction and Preparation Site Selection 5ft(1.52m) C i , ®� 3ft (os1 m) Sft(091 m) bi SO III Figure a-1. Insfallagon Cfearances 5 ft (1.52 m) , , aft III B i 0.91 m) I O ID Desoription Comments A Tap ofgenelator — 8 Front and end clearance Alinimum clear distances cannot include shrubs, bushes, or trees. C Rear dearanea Is in (a 7 cm) minimum oleetanaa per NFPA testrng, labeang, and riling, unfess state orlocat codes dictate othem4se. No operable windows, doors, or openings in the wall are permitted within 5 it (1.62 m) from airy pond of hegenerator. *DVV7ndoWswWopsnlngs One-heurftrated wells allow closer placement of the generatorsetOon&mbeforeinsEaRation,nce Removable fence panels for servicing cannot be placed less than 3 it (0.s1 m) in front of the generator.arance 5 it (1.62 m) minimum distance from any structure, overhang, orpro)ections from the Wall, DO NOT install under wooden decks or struchnes unless this distance is maintained. Installation Guidelines For60 Hz Air -Cooled Generators II Site Selection and Preparation Install the generator set, in its protective enclosure, outdoors where adequate cooling and ventilating air is always available (F6gara & 1). Consider these factors: — ja=n oT me generator must comply strictly with ICC IFGC, NFPA 37, NFPA 54, NFPA 58. and NFPA 70 standards. Install the unit where air inlet and outlet openings will not become obstructed by leaves, grass, snow, etc• if prevailing winds will cause blowing or unit. Windbreak consider using a Windbreak to protect the unit. ' Install the generator on high ground where water levels will not rise and endanger it. This unit should not operate in or be subjected to standing water. ° Allow sufficient room on all sides of the generator for maintenance and servicing. This unit must be installed In accordance with any local, state, or national cocas for minimum distances from other structures. 0 Clearance from the ends and front of the generator must be 3 ft (0.g1 m). This includes shrubs, bushes, and trees. Clearance from the back hr the generator must be a minimum of 18 e ack4s7 f th Clearance at the top should be a minimum of 5 ft (1.52 m) from any structure, overhang, or projections from the wa1L ° DO NOT install under wooden decks or structures unless there is st least 5 ft (1.52 m) of clearance above the generator, ° Install the Unit Where rain guitar down spouts, roof N�rT; landscape irrigation, water sprinklers, or SUMP pump discharge does not flood the unit or sA th The generator must be installed on a level sur. face. The generator must be level within a o.5 in 03_mm)-all-around — The generator is typically placed on pea gravel, compacted soil, crushed stone, or a concrete Pad- Check local codes to see what type is required, If a concrete pad is required, all appli- cable codes should be followed. Installation Guidelines for Stationary Air -Cooled Generators NFPA 37 is the The National Fire Protection Association's standard for the installation and use of stationary combustion engines. Its requirements ►imit the spacing of an enclosed generator set from a structure or wall (1igm e & 1). NFPA 37, Section 4.1.4, Engines Located Outdoors: Engines, and their weatherproof housings if provided, that are from (1,52 m) from openOP outdoors shall be located at least 5 ft ings In walls and at least 5 ft (1.52 m) from structures having combustible wails. A minimum separation shall not be required where the following conditions exist: 1 • The adjacent wall of the structure has a fire reslatance rating of at least one hour. 2 The The enclosure is constructed of noncombustible materials and it has been demonstrated that a fire within the enclosure will not ignite combustible materials outside the enclosure. Annex A — Explanatory Material ray a enclosure, Including any air Intel or outlet A4.1.4 (2) Means of demonstrating openings, means of full scale fire Pest or by calculation Procedures. are by Install the unit where services Will not be affected Ee an se ofprocedures. or Obstructed, including concealed, underground, available for the limited it hasebe become s that as frequently or covered services such as electrical, fuel , phone, exception (2) would be beneficial for manyapparent that air conditioning, or irrigation. This could affect and commercial Installations. With that n residential the warranhrcoverage. manufacturer contracted i Where strong prevailing Winds blow from direction, face the generator air inlet openinone gs to the prevailing winds. Install the generator as close as possible to the fuel supply to reduce the length of piping. REMEM{3ER THAT LAWS OR CODES MAY REGULATE THE DISTANCE AND LOCATION. in the absence of local codes regarding placement or clearance, we recommend following these guidelines: Install the generator as close as possible to the transfer switch. REMEMBER THAT LAWS OR LOCATION. CODES MAY REGULATE THE DISTANCE AND 12 laboratory to run full scale a to is toe assures tthat fithhe enclosure will not ignite combustible materials outside the enclosure. NOTE: Southwest Research Institute testing approves 18 in (457 Trim) instalation minimum from structure (Flgore 3••i, C). Southwest Research Institute is a nationally recognized third party testing and listing agency. The oriteria was to determine the worst case fire scenado Within the generator and to determine the Ignitability of items outside the engine enclosure at various distances. The enclosure is constructed of non-combustible Matsdals, and the the 4W pendent testing lab results d that any fire wnclusions hin the lnstalletion Guidelines For BD HzAtr-Cooled Generators Optional Load Calculation Heat Larger Than Air 61)13 89 SF x 3VA Living Only (2) Small appliance ckts @ 1500VA each Refrigerator @ 1500 Refrigerator @ 1500 Freezer @ 1500 Washing Machine @ 1500 Dishwasher @ 1500 Disposal @ 1500 Mini Sewer @ 1500 Clothes Dryer @ 5000 Range @ 12000. Water heater @ 4500 Fixed microwave @ 1500 Vacuum @ 1500 Trash Compactor @ 150D Pool Heater @'name plate' Spa @ 'nameplate' 1, S In p Motors 746VA per HP pool 1,5 Garage Door Opener 1) Total 2) First 10 KVA of general load @ 100% 3) Subtract line 2 from 1 4) Multiply line @ 40% 5) Add lines 2 and 4 6) 60/50amp breaker for heat (10000) 7) 40/30amp breaker for heat (5000) a) Total heat -Add lines 6 and 7 9) Multiply line 8 @ 65% 10) Add lines 5 and 9 11) Divide line 10 by240,, Summary: Line 10 is the total KW Line 11 is the total Amps 71SZ 3000 - r 00 - /500 500 - Illy) = 111 = 35o - l0000 - Co SOS A0591[0 (Generator size Needed) 5,31 (Breaker size Needed)