HomeMy WebLinkAboutTRUSS PAPERWORKll�
MV[
_^
a
Lumber design values are in accordance with ANSI/TPI 1 section 6.3
These truss designs rely on lumber values established by others.
RE: MONO —PEAK- MiTek USA, Inc.
Site Information: 16023 Swingley Ridge Rd
Chesterfield, MO 63017
Customer Info: . Project Name: Model: 314434-1200
Lot/Block: Subdivision: SCANNED
Address: Address
City: City By
State: State 'St. Lucie Coup
ty
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017ITP12014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: ISOmph
Roof Load: 34.0 psf Floor Load: N/A psf
This package includes 1 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
INo.
Seal#
ITruss Name
Date
1
132521125
1 SWM0040
2/23118
IYIM INC.
This item has been electronically signed and sealed by Wert, David, PE using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on
any electronic copies
The truss drawing(s) referenced above have been prepared by MiTek
USA, Inc. under my direct supervision based on the parameters
provided by Southern Wood Components.
Truss Design Engineer's Name: Wert, David
My license renewal date for the state of Florida is FEBRUARY 28, 2019.
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdidion(s) identified and that the
designs comply with ANSlrrPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTelrs customers
file reference purpose only, and was not taken into amount in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and propedy incorporate these designs
into the overall building design per ANSIfTPI 1, Chapter 2.
.y
sTA?E O�
lF�F PptF3YV F{k541ti`tl
'naq i;.X3[i'F. Sa 3i%3i
6;a
February 23,2018
Wert. David 1 of l
Joe Truss Truss Tyl
MONO PEAK svoilo40 MONOTB
SONhem VJond Compogents. Moulins. GA 31 T]6
6.2-8 ---
D-10.0 6 218 -
R
132521125
1x3
4
fx3 II ;x3 = 6
3x5 = 4x6 II
LOADING (psr)
SPACING.
1-4-0
CSL
OEFL.
in
(lot)
Udell
Vd
TCLL 20.0
Plate Grip DOL
1.15
TC
035
VerdLL)
0.18
7
999
240
TCDL 7.0
Lumber DOL
1.15
BC
C.33
Vert(CT)
OA5
7
999
180
BCLL 0.0 '
Rep Stress Incr
YES
WB
0.30
Horz(CT)
-0o4
5
this
n/a
BCDL 7.0
Code FBC2017ITPI2014
Matra-MRH
LUMBER-
TOPCHORD
2x4 SP No.2
BOT CHORD
2x4 SP No2
WEBS
2x3 SP No.2
REACTIONS.
(lbrsize) 1=370/0-3-8, 5=330/Mechanical
Max Holz 1=221(LC 6)
Max Uplift 1=-586(LC 6), 5=.563(LC 6)
FORCES. (lib) - Max. Comp./Max. Ten. - All forces 250 (to) or less except when shown.
TOP CHORD
1-2=-1079/1715, 2.3=573/903
BOT CHORD
1.7=.1869/1122, 6-7=-1867/1122, 5-6=-9931601
WEBS
3.5=.677/1118, 2.6=.5461912
PLATES GRIP
MT20 2441190
Weight'. 611b FT=20%
BRACING.
TOP CHORD Structural wood sheathing directly applied or 5-6-1 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 4-2.5 oc bonding.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust) Vasd=139mph; TCDL=4.2psf, 3CDL=42psf; h=33ft; B=49ft; L=15ft; eave=4ft;
Cat II; Exp D; Encl., GCpi=0.18; MWFRS (directional) and C-C EMerior(2) zone; Cantilever left exposed ;CC for members and
forces & MWFRS for reactions shown; Lumber DOL=160 plate grip DOL=1.60
2) This truss has been designed for a 10.0 par bottom Cheri live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live lead of 20opsf an the bottom chard in all areas where a rectangle 3.6.0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 586 to uplift at joint 1 and 563 lb uplift
atjoint5
This item has been
electronically signed and
sealed by Wert, David, PE
using a Digital Signature.
Printed copies of this
wrw,.,.,
document are not considered
p��PpO1�°'• ice"
signed and sealed and the
I�IIF7INC.
%fin=��
signature must be verified
on any electronic copies.
DaridO.lbe3F?r.$;8i
ui Inc FLC_:09
87Zi �r¢� rdg<Rg3d. CCm:g,d9. ti0 K++! 8
Nat
February 23,2018
A
GZ>, WARNING Varelydedgi Parameters, andREAD Named ON THIS AND INCLUDED MREK REFERENCE FAGEMIL><]J IMOW&rs BEFORE USE
Design veld for use only ilb MTicm d We design based only upon p Irsshovnadl! a dAdual buldg camponenl notal
5�1
s ryslem.Before use NeMitsgdesignermustverilyNeappllcaDlltydtlasgnparametersandpWarlynadmorslethisdesignIntoNeoverall
buflomgdeslgn. Bradngimitated IstopreventbucklingofirdMdual=Ssweb andia,Mommembers only. Addhoseltemporary and permanentbreang
Well,
is aywayz required for stability and to prevent collapse with posside personal lhury and prep" damage. For general guidance regarding rue
fabrication, storage.delivery. eredlon and bracing oftmsses and Wes Writers, see ANSI/TPD Duality enter,DSB-89 and BCm Bullolng Cgmpgnant
16023 Ewthgley Ridge Rd
Safetylnformaten available horn Truss Rate institute. 218 N.Lee Street.Suile312.A1exanomLVA2ZH4,
Chesterfield, Me 63017
Symbols
PLATE LOCATION AND ORIENTATION
Center plate on )Dint unless x. Y
offsets are indicated.
Dimensions plate are ioh sides
oftr hs.
Apply plates to both sides of truss
and fully embed teeth.
0.5tgr
It
—C
��F,!,,,4x 2,odentation, locate
pas 0- ens from outside
edge of truss.
This symbol indicates the
required tlirectien of slots in
connector plates.
Plate Ioodli details available In MITek 2012D
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown andfor
th
by text in the bracing section of the
output. Use Tor I bracing
if indicated.
BEARING
Indicates location where bearings
(supperts),occur. Icons varybut
dlo reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSIrrPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB39: Design Standard for Bracing.
BCSI: Building Component Safely Information.
Guide to Good Pmcbce for Handling,
Installing & Bracing of Metal Plate
Connected W,00d Trustee.
Numbering i System
64-8 1 1tlime(Drarons shownl t wale)
(Drzwinge not to scale)
1 2 3
TOP CHORDS
O WEBS n yy qy 4
L ` h 3 O
V u 3p n Z
0 0
� o
BOTTOM CHORDS
6 7 6 5
JOINTS ARE GENERALLY NUMBEREWLETTEREO CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY ENO JOINT
NUMSERSILETTERS.
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-IZJ—E"- 35ZFf i 19S .
ER-39M%2 2, F 39 .
es—
r\IAINC,
Trusses are designed forwind loads In the plane ofthe
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
® 2012 Mi repel, All Rights Reserved
MiTek�A
e
Welt Engineering Reference Sheet Mll-7473 rev. IG03MI
General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
t. MJNmul NatiYly Olxirgbrtrues system, a g.
ldxganat or X-datlng aaMaya reguveE See SCSI
2. Tmsbracbugmuetbedlv9redbyanenglneer.For
came ever spaang, InmNdual liters! Mertes NemSMves
may norl Gating, or aftemalNe Tor I
baren, shaWE be comldered
3 NovGe eO Ua desgn batingcMvn and never
wet ma@da5 on NadegearelY Greed rweses.
4. Provide cowaa of Nis w59 design m the Wilding
al otrreerreveresred ""rer, popery ovrer and
5. our rmmbere to loser tell agvnot eaen Me'.
8 Awe swe on earth rage of loves at Seth
law and travel WIN. Knorr aw were at joint
mehe, m are regulated W ANa1RP11.
Gotten aaurew tmssea call W wibbly potetted men
the emlmnerent nowed lh ANS!?P! 1
8 Unless eMenxise noted moisture corm of umWr
9. Umwexpresslymletl,IHswwp 1snotap,I
em wry tine retarow preurhae treated. or green lumbel.
10 camberSanon-ativcNral bbnsiderabbn and S ire
re$nrwria,cfwsamGlwer Generel'artureeto
comber W r deed load denecton
11 Ratetype s'a onenNSen and bcarondimemions
n coated are owourn pahr2 n oprernts,
12 Wmber used shall be ofthe Spaces and we, Gtl
fipaaft mapects equal W or berer flan met
13, Top shares meat be shea8ed or rvnir5lxonced at
Spin yNdienedondesgn.
14. Gotten Gods requve triers! toner, at 18 R SPOT
or less, E no wAilg is IMIM d.1. eiriewes noted.
15tom uors net Srorvn are tlo resparrsidlM of eme.
fe Do nor Set w after tree member or pate wltheee loner
approvilofaner-I veer.
17 LEtalt and load vedlwlN tulles indicated onoewise.
16 Use dgreen or treated Nmber nay pose uewepape
ental MpNo peMmaluce r¢ks. cansJlwlN
Pored eeg near before Ice.
19. Review ah penews of we d 19 (bent back words
and plclwesl befoe ever. Rewerving whues alone
PS not elurtent
28. Design assume maMaeturem areords. with
PNSmR 1 Deaury croons
Destiny Industries, LLC
M E663-662-108
Site Address: tbd
Building Codes: 2017 Florida Building Code, 61h Edition
FL PE Lic. No. 77316
45 Woodyards Cave Rd
Parkersburg, WV
26104
12/5/2018
DATE 116120I8 CERT.SO 56
PLANNUNMER NtF12437-NIE461-662-108,
APYROCED BY -- - - _
Resources Used: Microsoft Excel for computations; Woodworks Sizer 10.4 for selected beam designs
Calculation Index:
Design Criteria and Load Cases
MWFRS Design
Uplift / Truss Connections
Headers / Studs / Connections
Overhang Design / Connections
1\IF'I
INC.
``YYYuuniPT�
.. ..........
N ;
E C,Qts
No 77316
=."0: : W`
�0 STATE OF :
�
"ell
�4.O R t
e is
�'
Dec 05, 2018
Page(s)
1-2
3-9
10-13
14-25
26
Erik Myers PE, PLLC
11/26/2018
- ^esign-Criteria-ASCE-7-10 -
Total Width =
29.67 ft
Stories = 1
Module Width=
14.83 ft
Wall Height= 9 ft
Length =
66 ft
Sidewall Eave Height = 10 ft
Roof Slope =
2 /12
Foundation Height = 3.5 ft
Roof Angle =
9.46 0
Roof Projection = 3.00 ft
Sidewall OH =
12 in
Mean Roof Height = 15.00 ft
Endwall OH =
12 in
Min. Mean Roof Height = 15 ft
Wind Loads
Components and Cladding
Wind Speed =
160 mph
+
Exposure =
D
Zone 1 -37.2 23.4 psf
Wind Pressure qh =
34.4 psf
Zone 2 -64.7 23.4 psf
Zone 2 OH -95.7
Design Loads
Zone 3 -81.9 23.4 psf
Floor Live =
40 psf
Zone 3 OH -133.6
Floor Dead =
10 psf
Zone 4 -44.1 40.6 psf
Wall Dead =
45 plf
Zone 5 -54.4 40.6 psf
Roof Dead =
14 psf
Main Wind Force Resisting System
Roof Loads
Trans Long
Roof Live =
20 psf
Wall 39.9 35.8
Min. Roof Live =
20 psf
EZ Roof -17.0 -17.0
Ground Snow =
0 psf
Wall 26.5 23.8
Flat Roof Snow =
0.0 psf
IZ
Roof -9.9 -9.9
Sloped Roof Snow =
0.0 psf
Max Unbalanced =
0.0 psf
Soffit Loading for Overhang
Positive = 42.7 psf
Negative = -51.7 psf
a...�w.Ao..
.,.. a�
.�
PVPROVm BY
Fy�UHe
N1 NC.
& _
psf
psf
psf
psf
1
Design Criteria
Wind Speed:
Wind Exposure:
Mean Roof Height:
Roof Live Load:
Roof Dead Load:
Wall Dead Load:
Floor Live Load:
Floor Dead Load:
Attic Live Load:
Truss Reactions
Uplift
Gravity
Vertical Load Cases
Roof Level
D
L
Lr
W
.75(L+Lr)
D+L
D+Lr
D+.7S(L+Lr)
.6D+.6W
Floor Level
D
L
Lr
W
.75(L+Lr)
D+L
D+Lr
D+.75(L+Lr)
.6D+.6W
Building Dimensions
160 mph
Length:
66 ft
D
Width:
29.67 ft
15.00 ft
Module Width:
14.83 ft
20 psf
Wall Height:
9 ft
14 psf
Roof Pitch:
2 /12
45 plf
Truss Spacing:
16 in
40 psf
Heel Height:
5.5 in
10 psf
Slope Factor:
1.014
20 psf
Calculated Kh Reduction = Yes
Sidewall
Matewall
Horizontal
-586 Ibs
-563 Ibs
F =
370lbs
330lbs
Erik Myers PE, PLLC
11/26/2018
0,701575
221 Ibs
115 plf
103 plf
0 plf
plf
162 pif
145 plf
-568 plf
-542 plf
122 plf
109 plf
115 pif
103 plf
278 plf
248 plf
237 plf
211 plf
-272 plf
-263 plf
Rm iy 48nnmmtt cl
fmpn -
234 plf
.uvaew&dug
222 plf -
297 plf
297 plf T�""�"°�OB9� ^�• __ _
162 plf
145 plf
INC.IrIM
-568 plf
-542 plf
344 plf
331 plf
531 plf
518 plf
397 plf
367 plf
579 plf
553 plf
-200 plf
-192 plf
R)
Wind Speed: 160 mph
Wind Exposure:
D
Mean Roof Height:
15.00 ft
Length:
66 ft
Width:
29.67 ft
Module Width:
14.83 ft
Wall Height:
9 ft
Roof Pitch:
2 /12
Truss Spacing:
16 in
Roof Projection:
3.00 ft
Wind Load at Roof Level
Perpendicular to Ridge:
Parallel to Ridge:
Wind Load at Floor Level
Perpendicular to Ridge:
Parallel to Ridge:
MWFRS Horizontal Loads
Trans
Long
EZ Wall
39.9
35.8 psf
Roof
-17.0
-17.0 psf
IZ Wall
26.5
23.8 psf
Roof
-9.9
-9.9 psf
EZ2a= 6ft
Wall Sheathing Suction
Stud Spacing =
Zone 4 -44.1 psf
Zone 5 -54.4 psf
4119 Ibs
2331 Ibs
9153 Ibs
4467 Ibs
�,
inw
MFFRjOVm f
Poem
IY
ilINC.
,,,,�
^•
W=
16 in
Edge Field
6
6
Erik Myers PE, PLLC
11/26/2018
109 Ibs
12 in o.c.
12 in o.c.
3
Wall
1
Wood Species=
SP Sg= 0.55
Wall H =
9 ft
Grade =
#2 Size = 2x6
Force =
4119 Ibs
Stud Spacing =
16 in o.c. Fc1= 565 psi
FHS =
29.67 ft
Segmented
Fc-L Controls
Vu =
139 plf
Allowable Load = 4662 Ibs
OT=
1249-Ibs
Qty-= 1-stud
Sheathing /
Fastening
7/16" OSB
One Side with 0.113 " nails
Edge Spacing =
6 in. o.c. Fastener Length
Field Spacing =
12 in. o.c. L = 2.375 in
Allowable Shear =
275 plf >>> PASS
Gable End Plate to Top Plate
Stud Spacing = 16 in. o.c.
Out -of -Plane F = 159 Ibs / bay
In -Plane Shear F = 185 Ibs / bay
FR= 185 Ibs / bay
Bottom Plate to Floor (Sheathing Lap)
Stud Spacing = 16 in. o.c.
Out -of -Plane F = 159 Ibs / bay
In -Plane Shear F = 0 Ibs / bay
FR= 159lbs/bay
Sheathing to Top Plate / Band (Straps)
In -Plane Shear F = 139 plf
Uplift F = 0 plf
FR= 139 plf
Sheathing to Floor Band (Straps)
In -Plane Shear F = 139 plf
Perf. Uplift F = 0 plf
FR= 139 plf
Sheathing to Floor Band (Without Straps)
In -Plane Shear F =
139 plf
Uplift F =
0 plf
Perf. Uplift F =
0 plf
FR=
139 plf
Fastening Options
2 .131" toe -nails / bay
2 #8 toe -screws / bay
Fastening Options
2 .131" nails/bay
Fastening Options
6 in. o.c. .131" nails
Fastening Options
6 in. o.c. .131" nails
Fastening Options
6 in. o.c. .131" nails
Erik Myers PE, PLLC
11/26/2018
IYIt'I INC.
FI
Wall
2
Wood Species =
Wall H =
9 ft
Grade =
Force =
2331 Ibs
Stud Spacing =
FHS =
43.5 ft
Perforated
Vu =
66 plf
Perforated Design
OT=
592-Ibs
%-FHS=-0.74
Co = 0.81
Sheathing / Fastening
Truss to Top Plate
Truss Spacing =
Out -of -Plane F =
In -Plane Shear F =
Fa=
7/16" OSB
Edge Spacing =
Field Spacing =
Allowable Shear =
16 in. o.c.
221 Ibs
88 Ibs
221 Ibs
Bottom Plate to Floor (Sheathing Lap)
Stud Spacing = 16 in. o.c.
Out -of -Plane F = 159 Ibs / bay
In -Plane Shear F = 0 Ibs / bay
F R= 159 Ibs / bay
Sheathing to Top Plate / Band (No Straps)
In -Plane Shear F = 66 plf
Uplift F= 272 plf
FR= 279 plf
Sheathing to Floor Band (Straps)
In -Plane Shear F = 66 plf
Perf. Uplift F = 66 plf
F R= 93 plf
Sheathing to Floor Band (Without Straps)
In -Plane Shear F =
66 plf
Uplift F =
227 plf
Perf. Uplift F =
65.82 plf
F R=
300 plf
SP Sg = 0.55
#2 Size = 2x6
16 in o.c. Fc-L= 565 psi
Fc-L Controls
Allowable Load = 4662 Ibs
qty= 1 stud
One Side with 0.113 " nails
6 in. o.c. Fastener Length
12 in. o.c. L= 2.375 in
275 plf>>> PASS
Fastening Options
3 .131" toe -nails / truss
3 #8 toe -screws / truss
Fastening Options
2 .131" nails / bay
Fastening Options
4 in. o.c. .131" nails
Fastening Options
6 in. o.c. .131" nails
Fastening Options
4 in. o.c. .131" nails
Erik Myers PE, PLLC
11/26/2018
..b
It'I
INC.
5
Wall
3
Wood Species =
SP
Sg = 0.55
Wall H =
9 ft
Grade =
#2
Size = 2x6
Force =
4119 Ibs
Stud Spacing =
16 in o.c.
Fc-L= 565 psi
FHS =
29.67 ft
Segmented
Fcl Controls
Vu =
139 plf
Allowable
Load = 4662 Ibs
OT=
1249 Ibs
Qty= S stud
Sheathing /
Fastening
7/16" OSB
One Side with
0.113 " nails
Edge Spacing=
6 in. o.c.
Fastener Length
Field Spacing =
12 in. o.c.
L = 2.375 in
Allowable Shear=
275 pif>>>PASS
Gable End Plate to Top Plate
Stud Spacing = 16 in. o.c.
Out -of -Plane F = 159 Ibs / bay
In -Plane Shear F = 195 Ibs / bay
F R= 185 Ibs / bay
Bottom Plate to Floor (Sheathing Lap)
Stud Spacing = 16 in. o.c.
Out -of -Plane F = 159 Ibs / bay
In -Plane Shear F = 0 Ibs / bay
FR= 159lbs/bay
Sheathing to Top Plate / Band (Straps)
In -Plane Shear F = 139 plf
Uplift F = 0 plf
F R= 139 plf
Sheathing to Floor Band (Straps)
In -Plane Shear F = 139 plf
Perf. Uplift F = 0 plf
FR= 139 pif
Sheathing to Floor Band (Without Straps)
In -Plane Shear F =
139 plf
Uplift F=
0 plf
Perf. Uplift F=
0 plf
F R=
139 plf
Fastening Options
2 .131" toe -nails / bay
2 #8 toe -screws / bay
Fastening Options
2 .131" nails/bay
Fastening Options
6 in. o.c. .131" nails
Fastening Options
6 in. o.c. .131" nails
Fastening Options
6 in. o.c. .131" nails
Erik Myers PE, PLLC
11/26/2018
'
APPROY®9Y
Mune9u
I�IIMINC,
N
�hearwall-Connections— - -
Wall
4
Wood Species =
Wall H =
9 ft
Grade =
Force =
2331 Ibs
Stud Spacing =
FHS =
42.5 ft
Perforated
Vu =
75 plf
Perforated Design
OT=
672 Ibs
%FHS= 0.71
Co = 0.73
Sheathing / Fastening
Truss to Top Plate
Truss Spacing =
Out -of -Plane F =
In -Plane Shear F =
FR=
7/16" OSB
Edge Spacing =
Field Spacing =
Allowable Shear =
16 in. o.c.
221 Ibs
100 Ibs
221 Ibs
Bottom Plate to Floor (Sheathing Lap)
Stud Spacing = 16 in. o.c.
Out -of -Plane F = 159 Ibs / bay
In -Plane Shear F = 0 Ibs / bay
F R= 159 Ibs / bay
Sheathing to Top Plate / Band (No Straps)
In -Plane Shear F = 75 plf
Uplift F = 272 plf
FR= 282 plf
Sheathing to Floor Band (Straps)
In -Plane Shear F = 75 plf
Perf. Uplift F = 75 plf
FR= 106 plf
Sheathing to Floor Band (Without Straps)
In -Plane Shear F = 75 plf
Uplift F = 227 plf
Perf. Uplift F = 74.638 plf
FR= 310 plf
SP Sig = 0.55
#2 Size = 2x6
16 in o.c. Fc-L= 565 psi
Fc-L Controls
Allowable Load = 4662 Ibs
Qty= 1 stud
One Side with 0.113 " nails
6 in. o.c. Fastener Length
12 in. o.c. L= 2.375 in
275 plf >>> PASS
Fastening Options
3 .131" toe-nails/truss
3 #8 toe -screws / truss
Fastening Options
2 .131" nails / bay
Fastening Options
4 in. o.c. .131" nails
Fastening Options
6 in. o.c. .131" nails
Fastening Options
4 in. o.c. .131" nails
Erik Myers PE, PLLC
11/26/2018
pmmrq..wn
Rnsaq
4A-�mMtt al
-
yu®uyeaeq
3
APPBB BY
�j�
�
PB
m
�CY
Yb!0 B
7
Erik Myers PE, PLLC
11/26/2018
1 139
7/16"
OSB One Side w/ 0.113"
x 2.375"
nails
6 12
2 66
7/16"
OSB One Side w/ 0.113"
x 2.375"
nails
6 12
3 139
7/16"
OSB One Side w/ 0.113"
x 2.375"
nails
6 12
4 75
7/16"
OSB One Side w/ 0.113"
x 2.375"
nails
6 12
1 OT =
End Plate to Top Plate
2 .131" toe-nails/bay
2 #8 toe -screws / bay
Plate to Floor (Sheathing Lap)
2 .131" nails/bay
to Top Plate / Band (Straps)
6 in. o.c. .131" nails
to Floor Band (Straps)
6 in. o.c. .131" nails
to Floor Band (Without Straps)
6 in. o.c. .131" nails
3 OT =
End Plate to Top Plate
2 .131" toe-nails/bay
2 #8 toe -screws / bay
Plate to Floor (Sheathing Lap)
2 .131" nails/bay
to Top Plate / Band (Straps)
6 in. o.c. .131" nails
to Floor Band (Straps)
6 in. o.c. .131" nails
to Floor Band (Without Straps)
6 in. o.c. .131" nails
Wall 2 OT = 593 Ibs
Truss to Top Plate
3 .131" toe-nails/truss
3 #8 toe-screws/truss
Bottom Plate to Floor (Sheathing Lap)
2 .131" nails / bay
Sheathing to Top Plate / Band (No Straps)
4 in. o.c. .131" nails
Sheathing to Floor Band (Straps)
6 in. o.c. .131" nails
Sheathing to Floor Band (Without Straps)
4 in. o.c. .131" nails
Wall 4 OT = 672 Ibs
Truss to Top Plate
3 .131" toe-nails/truss
3 #8 toe-screws/truss
Bottom Plate to Floor (Sheathing Lap)
2 .131" nails / bay
Sheathing to Top Plate / Band (No Straps)
4 in. o.c. .131" nails
Sheathing to Floor Band (Straps)
6 in. o.c. .131" nails
Sheathing to Floor Band (Without Straps)
4 in. o.c. .131" nails
'
RPPgOV®9Y
ws�uge
e
IY
AINC.
H.
— - Roof -Diaphragm--
Roof Diaphragm
V= 4119lbs
Unit shear= 130 plf
Floor Diaphragm
7/16" sheathing w/ .113" nails: 250 plf
6" ox. edge, 12" o.c. field
V= 5034lbs
19/32"
sheathing w/.113" nails: 275p1f
Unit shear = 170 plf
6" o.c. edge, 6" o.c. field
Suction Fastening Requirements (spacing limited to diaphragm spacing requirements)
Roof Sheathing Suction
W =
109 Ibs
Stud Spacing =
16 in
Edge
Field
Zone 1 -37.2 psf
6.0
12.0 in o.c.
Zone 2 -64.7 psf
6.0
12.0 in ox.
Zone 2 OH -95.7 psf
6.0
10.3 in o.c.
Zone 3 -81.9 psf
6.0
12.0 in ox.
Zone 3 OH -133.6 psf
6.0
7.3 in ox.
Roof Diaphragm Deflection (3 term equation)
W =
125 plf
MaxT/C=
2146lbs
Chord E=
1400000 psi
Chord A=
8.25 inA2
Ga =
13 kips/in
Ac =
0.038682
Hallow=
2L/ 120
Chord Splice
S — 5vP + 025vL + �, (XAO )
8EAW 1000G, 2W
term 1 = 0.12723 in
term 2 = 0.32873 in
term 3 = 0.06412 in
bdia= 0.52008 in
OK
MaxT/C=
2146lbs Tension Controls
F'=
600 psi
F"=
960 psi
AllowableT=
7920lbs
Fasten chord splice with 0.131 in. nails, 13 each side of splice
Erik Myers PE, PLLC
11/26/2018
QIMINC.,,°'�—
W
UpliftConnections
Uplift Forces
Sidewall
Uplift =-412lbs
Sidewall - OSB Overlap at Top Plate
F= 282 plf
Fastener= .113 nails
Z= 941bs
Nail Spacing= 4 inches o.c.
Rows = One Row
Lap Sheathing Over Top Plate and
Fasten with One Row of .113 nails
at 4 inches c.c.
Sidewall - Connection at Floor
F = 310 plf
Option 1 w/ Straps
LSTA9 614lbs
Fastener= .131" x 2.5" nail
Strap Spacing = 23 inches o.c.
Use LSTA9 strap 16 inches o.c., w/
(4) .131" x 2.5" nails
Option 2 w/ OSB Overlap
Fastener= .113 nails
Z= 94lbs
Nail Spacing= 3 inches o.c.
Rows= One Row
Lap Sheathing Over Top Plate and
Fasten with One Row of .113 nails
at 3 inches o.c.
Matewall
Uplift =-395lbs
LAP %, OSB OVER
BAND. FASTEN WITH
SPECIFIED FASTENER
AND SPACING.
STAGGER NAILS INTO
EACH TOP PLATE
EXT. OSB TO RIM
UPLIFT STRAPS
INSTALLED WITH
SPECIFIED FASTENERS,
AND SPACING
OPT 2
LAP SHEATHING
OVER BAN &
FASTEN WITH
SPECIFIED
FASTENER AND
SPACING
�"PAQ�Br
Erik Myers PE, PLLC
11/26/2018
10
UpliftConnections—
Matewall - Ridgebeam to Stud
F = -263 pif
LSTA9 614lbs
Fastener = .131" x 2.5" nail
Strap Spacing = 27 inches o.c.
Use LSTA9 strap 16 inches o.c., w/
(4) .131" x 2.5' nails
Matwall -Stud to Floor
F = -263 plf
Option 1 w/ Straps
LSTA9 614lbs
Fastener = .131" x 2.5" nail
Strap Spacing = 27 inches o.c.
Use LSTA9 strap 16 inches o.c., w/
(4) .131" x 2.5" nails
APPROV 6V
I�IIt11NC.
,m,,,v�
��—
Erik Myers PE, PLLC
11/26/2018
UPLIFT
STRAPS
INSTALLED
WITH
SPECIFIED
FASTENERS
AND
SPACING
11
Erik Myers PE, PLLC
11/26/2018
Truss Connections (Fixed Roof)
Truss Reactions Truss Chord Species = SP
Sidewall Matewall
Horiz.= 156lbs Gravity= 330lbs
Uplift = -412 Ibs Uplift = -395 Ibs
Top Chord Strap Across Mateline
T = 139 Ibs
Strap Options: Fasteners Each End: Value:
LSTA15 (4) .131" x 2.5" nails 615 Ibs OK
CS22 (4) .131" x 2.5" nails 653 Ibs OK
RIDGE CAP
TOP CHORD STRAP RIDGE TO RIDGE SHEAR
USE (I) SIMPSON LSTA15 FASTEN WITH (3) 8D (.131) X 3" NAILS
STRAP WITH (4) 80 (.131) X FROM RAIL TO RAIL EACH BAY EVENLY
2.5" NAILS EACH END. OR CS22 SPACED. BLOCK GAPS @ 32" O.C.
STRAP APPLY TO EVERY TRUSS. /
TOP CHORD TO RIDGE
FASTEN WITH (3) 8D (.131) X 3" NAILS
FROM RIDGE TO TOP CHORD END GRAIN.
APPLY TO EVERY TRUSS.
Uplift Uplift Connector at Sidewall Truss Heel
Connector Options: Fasteners Each End:
H2.5A (5) .131" x 2.5" nails
SDWC15600 .152" x 6" screw
TOP PLATE TO TRUSS UPLIFT
USE (1) SIMPSON H2.5A W(5) 8D (.131) X
1.5" FASTERS EACH END. EVERY TRUSS
ALTERNATE: FASTEN (1) SDWC15600
SCREW FROM DBL TOP PLATE INTO
THE BOTTOM CHORD OF TRUSS.
EXT. OSB TO PLATES
PER SHEARWALL CONNECTION CHART,
Value:
6001bs OK
615 Ibs OK
TOP PLATE TO TRUSS (SHEAR)
PER SHEARWALL CONNECTION CHART
INC.
12
Matewall Girder Connection Over Openings:
Gravity= 330lbs Gravity Controls
Uplift=-395lbs
Fastener: Quantity:
.131"nai( end grain
RIDGE BEAM
Erik Myers PE, PLLC
BOTTOM CHORD TO BAND
FASTEN BAND TO BOTTOM CHORD
WITH (7) 8D (.131) X 3.25" NAILS.
APPLY EVERY TRUSS EVENLY SPACED.
lea
MPPOVm BY
fn WryC
6t op�N
�
INC.
ItlI
13
Matewall Header
Species = Murphy
Grade =
LVL
b =
1.5 in
d =
9.25 in
A=
13.88 W2
S =
21.39 inA3
I =
98.93 inA4
Qty =
1
Fb =
3100 psi
Fv =
290 psi
E =
2000000 psi
Lr =
1
Cfb =
1
L+D
Mu =
34095.7 in-Ibs
Mn =
66310.94 in-Ibs
L+D
Vu =
1185.938 Ibs
Vn =
2682.5 Ibs
LLA =
0.14 in
TLA =
0.19 in
WA =
0.25 in
W =
-263 plf
ILL =
145 plf
DL =
103 plf
LLA = L/ 240
TLA = L/ 180
WA = L/ 240
Span =
115 in
L+D
Fb = 3100.00 psi
Fv = 290 psi
W
Mu = 27798.61 in-Ibs
OK
Mn = 106097.5 in-Ibs
W
Vu = 966.9082 Ibs
OK
Vn = 4292 Ibs
Allowable LLA =
0.48 in OK
Allowable TLA =
0.64 in OK
Allowable TLA =
0.48 in OK
Reaction Uplift Reaction
F = 1186 Ibs F = -1263 Ibs
Use (1) 1.5 x 9.25 LVL for 9' 7" span
BY
Eat• pH`�
�M�GflOY�Fll
IliDiNC.
Erik Myers PE, PLLC
11 26/2018
Ld= 1.6
Ld = 1
W
F'b = 4960.00 psi
Fv = 464 psi
OK
OK
1�
Matewall Header
Species = Murphy
W =
-263 plf
Grade = LVL
LL =
145 plf
b = 1.75 in
DL =
103 plf
d = 24 in
LLA = U 240
A = 42.00 inA2
TLA = U 180
S = 168.00 inA3
WA = L/ 240
1 = 2016.00 inA4
Qty = 1
Span =
282 in
Fb = 3100 psi
Fv = 290 psi
L+D
E = 2000000 psi
Fb = 3100.00
psi
Lr = 1
Fv =
290 psi
Cfb = 1
L+D
W
Mu = 205022.8 in-Ibs
Mu = 167157.4 in-Ibs
Mn = 520800 1n-Ibs
OK
Mn = 833280 in-Ibs
L+D
W
Vu =
2908.125 Ibs
Vu = 2371.027 Ibs
Vn =
8120 Ibs
OK
Vn =
12992 Ibs
LLA =
0.25 in
Allowable LLA =
1.18 in
OK
TLA =
0.33 in
Allowable TLA =
1.57 in
OK
WA =
0.45 in
Allowable TLA =
1.18 in
OK
Reaction Uplift Reaction
F = 2909 Ibs F = -3096 Ibs
Jse (1) 1.75 x 24 LVL for 23' 6" span
A
IYIF'IINC.�°e
Erik Myers PE, PLLC
12/5/2018_
Ld = 1.6
Ld = 1
W
Fb = 4960.00 psi
Fv = 464 psi
NJ I
15
Matewall Header
Species =
SYP
W =
-263 plf
Grade =
#2
LL =
145 plf
b =
1.5 in
DL =
103 plf
d =
5.5 in
LLA = L/ 240
A =
8.25 inA2
TLA = L/ 180
S =
7.56 inA3
WA = L/ 240
1 =
20.80 inA4
Qty =
1
Span =
48 in
Fb =
1000 psi
Fv =
175 psi
L+D
E =
1400000 psi
Fb = 1000.00
psi
Lr =
1
Fv =
175 psi
Cfb =
1
L+D
W
Mu =
5940 in-Ibs
Mu = 4842.949 in-Ibs
Mn =
7562.5 in-Ibs
OK
Mn =
12100 in-Ibs
L+D
W
VU =
495 Ibs
Vu = 403.5791 Ibs
Vn =
962.5 Ibs
OK
Vn =
1540 Ibs
LLA =
0.03 in
Allowable LLA =
0.20 in
OK
TLA =
0.04 in
Allowable TLA =
0.27 in
OK
WA =
0.05 in
Allowable TLA =
0.20 in
OK
Reaction Uplift Reaction
F = 495 Ibs F = -527 Ibs
Use (1) 2 x 6 #2 SYP for 4' 0" span
r,vrmswp
(esM
¢rmv.
tAmmnrtrcl
u.�ee�.urpm
BY
Ep wrt
i Nr�n
�M��P��EO��ED
Erik Myers PE, PLLC
_ _ 11/26/2018
Ld = 1.6
Ld = 1
W
Fb = 1600.00 psi
Fv = 280 psi
OK
M
WT
Erik Myers PE, PLLC
11/26/2018
Matewall Stud
W =
-263 plf
L =
108 in
Ke =
1
DL =
103 plf
d =
3.5 in
le =
108 in
LL =
145 plf
t =
1.5 in
le/d =
30.86 < 50 OK
Cd =
1
Spacing =
16 in
Cf(Fc) =
1
Cf(Fb) =
1
Fb psi Ft psi
Fv psi
Fc-L psi Fc psi
E psi
Emin psi
#3 SYP
650 400
175
565
850
1300000
470000
Qty
A (in42) S (in A3)
1 (inA4)
F'b psi F'c psi
1
5.25 3.06
5.36
650
850
2
10.50 6.13
10.72
650
850
3
15.75 9.19
16.08
748
850
Axial Compression
Qty FcE psi
oc
Cp
F'c psi fc psi fc/F'c
Capacity
1 406
0.48
0.42
355 246 0.69 OK
1863 Ibs
2 406
0.48
0.42
355 287 0.81 OK
3726lbs
3 406
0.48
0.42
355 308 0.87 OK
5589lbs
Lateral Bending
W =
5 psf
Qty M (in-Ibs)
F'c psi
fb psi
fb/F'c
1 406.00
650
132
0.20 OK
2 405.00
650
66
0.10 OK
3 405.00
748
44
0.06 OK
Combined Stresses
Max Load Max Span
city Axial
Lateral
Combined
(Ibs) (in.)
1 0.69
0.20
1.00
1293 110
2 0.81
0.10
1.00
3012 277
3 0.87
0.06
1.00
4854 455
R PRPflOVBY
EO
�
I AMC.
-
17
Erik Myers PE, PLLC
12/3/2018
- Floor Rim -Band -Spans- -LLD-=-L/ 360---
On-Frame Floor TLA = L/ 240
Sidewall Loading Matewall Loading
LL = 188 pif LL = 156 plf
DL = 231 plf DL = 216 pif
Sidewall Loading
Qty b d Spc Grade Fb Fb' Fv E
1 2 1.5 11.25 SP #2 750 750 175 1400000
2 3 1.5 11.25 SP #2 750 863 175 1400000
3 2 1.5 9.25 SP #2 800 800 175 1400000
4 3 1.5 9.25 SP #2 800 920 175 1400000
A S I M v LLA TLA Max Span
1 33.8 63.28 355.957 104 226 189 166 105 in
2 50.6 94.92 533.936 137 338 217 190 137 in
3 27.8 42.78 197.863 88.6 185 156 136 89in
4 41.6 64.17 296.795 116 278 178 156 117 in
Matewall Loading
Qty b d Spc Grade Fb Fb' Fv E
1 2 1.5 11.25 SP #2 750 750 175 1400000 e
2 3 1.5 11.25 SP #2 750 863 175 1400000
3 2 1.5 9.25 SP #2 800 800 175 1400000
4 3 1.5 9.25 SP #2 800 920 175 1400000 r�r^INC. �s -
A S I M v LLA TLA Max Span
1 33.8 63.28 355.957 111 254 201 173 111 in
2 50.6 94.92 533.936 145 381 231 198 146 in
3 27.8 42.78 197.863 94 209 166 142 94 in
4 41.6 64.17 296.795 123 313 190 162 124 in
Floor Loading
Qty b d Spc Grade Fb Fb' Fv E
1 1 1.5 11.25 SP #2 750 750 175 1400000
2 2 1.5 11.25 SP #2 750 750 175 1400000
3 1 1.5 9.25 SP #2 800 800 175 1400000
4 2 1.5 9.25 SP #2 800 800 175 1400000
A S I M v LLA TLA Max Span
1 16.9 31.64 177.979 78.3 127 160 137 79 in
2 33.8 63.28 355.957 111 254 201 173 111 in
3 13.9 21.39 98.9316 66.5 104 131 113 67 in
4 27.8 42.78 197.863 94 209 166 142 94 in
ummary
Max Spans
Sidewall - no
Sidewall w/ 1
Matewall' -no splice
Matewall - w/ 1 splice'
splice'
splice'
!) #2 SP 2x12
B. 9"
6' 2"
9' 3"
6' 7"
1) #2 SP 2x12
11' 5"
8' 9"
12' 2"
9' 3"
#2 SP 2x10
7' 5"
5' 3"
7' 10"
5' 7"
V) #2 SP 2x10
9' 9"
7' 5"
10' 4"
7' 10"
1. Rim joist splices at support locations. 2. One rim spliced between support locations.
EW
V
COMPANY r0n0FJrame
ECT
Erik Myers PE PLLC
-WOod-Wood
2805 28thSt-_-
u,/=,rpc=roaBoouue4w Parkersburg, WV26104
(304)-834-9510
JDec. 3, 2018 12:55 Floor Jo[st.wwb
Design Check Calculation Sheet
WoodWorks Sizer 10.2
I Loads:
Load
'
Type
Distribution
Pat-
tern
Location [ft]
Start End
Magnitude
Start End
Unit
Loadl
Dead
Point
No
0.00
310
lbs
Load3
Roof constr.
Point
Yes
0.00
250
lies
Load4
Roof constr.
Point
Yes
14.33
200
lbs
Load5
Live
Full Area
Yes
40.00 (16.0)*
psf
Load6
Dead
Full Area
No
10.00 (16.0)*
psf
Load7
Wind
Point
No
14.33
-800
lbs
Load9
Wind
Point
No
0.00
-850
lbs
Load10
Dead
Point
No
14.33
290
lbs
Self -weight
Dead
Full UDL
No
3.6
plf
*Tributary Width (in)
Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) :
, 14'-4"
2'-11.9"
1 V-3.4"
Unfactored:
Dead
Live
Wind
Roof Live
Factored:
308
77
-850
250
123
392
123
392
288
77
-600
200
Uplift
325
307
Total
558
515
515
496
Bearing:
Capacity
Joist
558
2437
2437
496
Supports
772
-
-
686
Anal/Des
Joist
1.00
0.21
0.21
1.00
Support
0.72
-
-
0.72
Load comb
#6
#12
#15
#28
Length
0.66
2.50
2.50
0.59
Min req'd
0.66
0.35
0.35
0.59
Cb
1.00
1.15
1.15
1.00
Cb min
1.00
1.75
1.75
1.00
Cb support
1.25
-
-
1.25
Fcp sup
625
-
I I
-
625
Lumber n-ply, S. Pine, No.2, 2x10, 1-ply (1-1/2"x9-1/4")
Supports: 1,4 - Timber -soft Beam, D.Fir-L No.2; 2,3 - Non -wood;
Floor joist spaced at 16.0" c/c; Total length: 14'-4.0";
Lateral support: top= full, bottom= at supports; Repetitive factor: applied where permitted (refer to online help);
By
ry°ce9u
�PP�PjO
IM11'9INC.
19
Woodworks@ Sizer SOFTWARE FOR WOOD DESIGN
On Frame Floor Joist.wwb Woodworks® Sizer 10.2 -Page 2-
Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2012:
Criterion
Anal sis
Value
Desi n
Value
Analysis/Desi n
Shear
fv =
25
Fv' =
175
fv/Fv' =
0.14
Bending(+)
fb =
155
Fb' =
920
fb/Fb' =
0.17
Bending(-)
fb =
194
Fb' =
684
fb/Fb' =
0.28
Live Defl'n
0.01 =
<L/999
0.28 =
L/360
0.05
Total Defl'n
0.02 =
<L/999
0.41 =
L/240
0.05
Additional Data:
FACTORS: F/E(psi)CD CM Ct CL CF
Cfu Cr Cfrt
Ci Cn
LC#
Fv' 175 1.00 1.00 1.00 - -
- - 1.00
1.00 1.00
12
Fb'+ 750 1.00 1.00 1.00 1.000 1.067
1.00 1.15 1.00
1.00 -
11
Fb'- 750 1.00 1.00 1.00 0.744 1.067
1.00 1.15 1.00
1.00 -
12
Fcp' 565 - 1.00 1.00 - -
- - 1.00
1.00 -
-
E' 1.4 million 1.00 1.00 - -
- - 1.00
1.00 -
11
Emin' 0.51 million 1.00 1.00 - -
- - 1.00
1.00 -
11
CRITICAL LOAD COMBINATIONS:
Shear : LC #12 = D+L (pattern: LL ), V =
294, V design =
233 Its
Bending(+): LC #11 = D+L (pattern: L ), M =
276 lbs-ft
Bending(-): LC #12 = D+L (pattern: LL_), M =
346 lbs-ft
Deflection: LC #11 = (live)
LC #11 = (total)
D=dead L=live S=snow w=wind I=impact Lr=roof live Lc=concentrated
E=earthquake
All LC's are listed in the Analysis output
Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern
load in this
span
Load combinations: ASCE 7-10 / IBC 2012
CALCULATIONS:
Deflection: EI = 139e06 lb-in2
"Live" deflection = Deflection from all non -dead
loads (live, wind,
snow...)
Total Deflection = 1.00(Dead Load Deflection) +
Live Load Deflection.
Design Notes:
1. Wood Works analysis and design are in accordance with the [CC International Building Code (IBC 2012), the National
Design Specification (NDS 2012), and NDS Design Supplement.
2. Please verify that the default deflection limits are appropriate for your application.
3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the
middle 2/3 of 2 span beams and to the full length of cantilevers and other spans.
4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1.
5. FIRE RATING: Joists, wall studs, and multi -ply members are not rated for fire endurance.
E Z
INC.
20
Erik Myers PE, PLLC
11/26/2019
Sidewall Headers
W = -272 plf LLA = U 240
DL = 115 pif TLA = U 180
LL = 162 plf Cd = 1
Gravity Loading
Qty
b
d
Grade
Species
Direction
Cfu
Cfb
1
3
1.5
3.5
#2
SYP
Edge
1
1
2
3
1.5
5.5
#2
SYP
Edge
1
1
3
3
1.5
7.25
#2
SYP
Edge
1
1
4
3
1.5
9.25
#2
SYP
Edge
1
1
5
3
1.5
11.25
#2
SYP
Edge
1
1
A (in A2)
S (in A3)
1 (in44)
Fb psi
Fv psi
Fc psi
E psi
Emin psi
1
15.75
9.19
16.08
1100
175
565
1400000
510000
2
24.75
22.69
62.39
1000
175
565
1400000
510000
3
32.63
39.42
142.90
925
175
565
1400000
510000
4
41.63
64.17
296.79
800
175
565
1400000
510000
5
50.63
94.92
533.94
750
175
565
1400000
510000
Fe
F,
FbE
CL
M
V
LLA
TLA
1
1265
175
3499
0.97
62.5
165.9
81.1
80.6
2
1150
175
1529
0.90
90.3
260.7127.4
126.7
3
1064
175
974
0.78
106.3
343.7167.9
167.0
4
920
175
681
0.67
117.1
438.5
214.2
213.1
5
863
175
512
0.56
125.8
533.3
260.5
259.1
pvamrµ.w P.
44wmamnl
unnmw6eq
�ua'imtenae
�s+v.
u�ama�nMavr+w
Irt��MIN..
IPP110VfL 6Y
pm pmaga
., ♦mv�rv.
I�IIt'1INC.
21
Erik Myers PE, PLLC
11/26/2018
Wind Loading
Ci£C =
44.06536 psf
MWFRS =
39.89964 psf
LLA = U
120
Cd =
1.6
Wall H =
108
in
Qty
b
d
Grade
Species
Direction
Cfu CA,
1
3
1.5
3.5
#2
SYP
Flat
1.1
2
3
1.5
5.5
#2
SYP
Flat
1.15
3
3
1.5
7.25
#2
SYP
Flat
1.15
4
3
1.5
9.25
#2
SYP
Flat
1.2
5
3
1.5
11.25
#2
SYP
Flat
1.2
A (in A2) S (in
A3) 1
(inA4)
Fb psi
Fv psf
FbEdge
FbFI.t
1
15.75
3.94
2.95
1100
175
2024
2226
2
24.75
6.19
4.64
1000
175
1840
2116
3
32.63
8.16
6.12
925
175
1702
1957
4
41.63
10.41
7.80
800
175
1472
1766
5
50.63
12.66
9.49
750
175
1380
1656
Lateral Only
Combined
M
v
LLA
M
v
1
65.1
222.4
61.2
51.84
100.76
2
79.6
349.5
71.1
66.99
156.62
3
87.9
460.7
78.0
75.02
205.50
4
94.3
587.8
84.6
80.99
261.37
5
100.7
714.8
90.3
86.48
317.23
Summary
Qty
b
d
Grade
Species
Direction
Max Span
1
3
1.5
3.5
#2
SYP
Edge
51.8 in
2
3
1.5
5.5
#2
SYP
Edge
67.0 in
3
3
1.5
7.25
#2
SYP
Edge
75.0 in
4
3
1.5
9.25
#2
SYP
Edge
81.0 in
5
3
1.5
11.25
#2
SYP
Edge
86.5 in
ns PdemT:vmM min iryf 45��m
��✓ ex gym: uiry r.,�nvt..�
ppPflOVFD BY
y' OW
i-M-
IrIMINC.
1
1
1
1
1
22
Erik Myers PE, PLLC
-- ---- -- - --- 11/26/2018 -
Sidewall Stud
W =
-272 plf
L =
103.5
in
Ke =
1
DL =
115 plf
d =
5.5
in
le =
103.5 in
LL =
162 plf
t =
1.5
in
le/d =
18.82 < 50 OK
span =
38 in
Cd =
1
Spacing =
16
in
Cf(Fc) =
1
Cf(Fb) =
1
Fb psi
Ft psi
Fv psi
Fc-L psi Fc psi
E psi Emin psi
#2 SYP
1000
600
175
565 1400
1400000 510000
Qty
A (in A2)
S (in A3)
1 (in A4)
F'b psi F'c psi
1
8.25
7.56
20.80
1000 1400
2
16.50
15.13
41.59
1000 1400
3
24.75
22.69
62.39
1150 1400
Axial Compression
Qty
FcE psi
ac
Cp
F'c psi fc psi
fc/F'c
Capacity
1
1184
0.85
0.63
883 76
0.09 OK
7281 Ibs
2
1184
0.85
0.63
883 38
0.04 OK
14563 Ibs
3
1184
0.85
0.63
883 25
0.03 OK
21845 Ibs
Lateral Bending
W =
54.4 psf
Qty
M (in-Ibs)
F'c psi
fb psi
fb/F'c
1
4046.34
1000
535
0.54 OK
2
4046.34
1000
268
0.27 OK
3
4046.34
1150
178
0.16 OK
Combined
Stresses
Qty
Axial
Lateral
Combined
Max Axial Combined
1
0.09
0.54
0.58
OK 3245 Ibs
2
0.04
0.27
0.28
OK 9873lbs
3
0.03
0.16
0.16
OK 17245lbs
2eaction Uplift Reaction
F = 624 Ibs F = -611 Ibs
Ise (1) 2 x 6 #2 SYP for 3' 2" span
(1) Jack / (1) Jamb
NA
INC.
23
e
V
Header Connections
Zone =
4
H =
80 in
W=
36 in
Wall H =
108 in
Stud =
16 in o.c.
C+C =
44.1 psf
Uplift =
272 plf
Fr =
336 plf
F =
504 Ibs
.131"Z=
114lbs
Header to King Stud
F =
504 Ibs
5 nails
Stud to Plate
W1 =
29 plf
W2 =
95 plf
R top =
547 Ibs
R bot =
442 Ibs
Max =
547 Ibs
5 nails
Uplift
Truss =
16 in o.c.
F =
588 Ibs
LSTA15
1110 Ibs
1 straps
Erik Myers PE, PLLC
11/26/2018
Zone 4-44.0654
Zone 5-54.3932
C +C = 198 plf
a = 68 in
C= 40 in
a�umgl�nn
umuuNEBw9
�mnT 48�mummM
�
esemnta�ewu
I^'
PoNm
�OYm 9Y
�n�a
�D
E6 OHe.
O
v
—Header Connections -
Zone =
4
H =
80 in
W =
72 in
Wall H =
108 in
Stud =
16 in o.c.
C+C =
44.1 psf
Uplift =
272 plf
Fr =
336 plf
F =
1009 Ibs
.131" Z =
114 Ibs
Header to King Stud
F =
1009 Ibs
9 nails
Stud to Plate
W1 =
29 plf
W2 =
162 pif
R top =
961 Ibs
R bot =
753 Ibs
Max =
961 Ibs
9 nails
Uplift
Truss =
16 in o.c.
F =
996 Ibs
LSTA15
1110 Ibs
1 straps
Zone 4-44.0654
Zone 5-54.3932
C +C = 198 plf
a = 68 in
c = 40 in
BY
pN;�
MFPOV�D�
AINC.
Erik Myers PE, PLLC
11/26/2018
25
f
Erik Myers PE, PLLC
11/26/2018
Overhang Calculation (Cantilever Under Top Chord)
Loading Conditions:
Loading Conditions:
1
Co: 1
1
LL:
20 psf
2
Co: 1.6
2
LL:
-95.704 psf LLA U 180
DL:
7 psf TLA U 180
Loading Conditions:
Width
Depth Species Grade
Fb Fv
E CF
2.5
1.5 SP #2
1100 175
1400000 1
Spacing
Qty A in2 S in
1 in" Cr
F'b F'v
E'
1a
16
1 3.75 0.9375
0.7031 1.15
1265 175
1400000
1b
16
1 3.75 0.9375
0.7031 1.15
1265 175
1400000
2a
16
1 3.75 0.9375
0.7031 1.15
2024 280
1400000
2b
16
1 3.75 0.9375
0.7031 1.15
2024 280
1400000
Design Limits
Bending Shear
Max Span
LLA
TLA
1a
28
147 28 in
0.0013 OK
0.0018 OK
1b
56
292 56 in
0.0098 OK
0.0132 OK
2a
19
67 19 in
0.0064 OK
0.0064 OK
2b
19
67 19 in
0.0560 OK
0.0560 OK
Connections: Overhang L:
Load at Load at
Truss Gable
1a
18
1b
18 -
2a
-32-319.01
2b
--287.11
12 in Truss Spacing = 24 in
Worst Case Reactions Normalized to Ld = 1.0
Load at Truss Load at Gable
20lbs 199lbs
Notes:
1a Overhang loaded only
1b Truss bay loaded only
2a Overhang loaded only
2b Overhang and truss bay loaded
Overhang equal to Truss Spacing
.131" x 3" nail (Ld=1.0) W = 31 Ibs
(3) nails per truss = 93 Ibs > 20 OK
Load at Gable = 199 Ibs
Bearing on Gable Endwall OK
Muprumx.M1al`
4b inom¢ci
RN
APPPOVm BY
w.agtl ix
IVIMINC.--
M-