HomeMy WebLinkAboutENERGY EFFICIENCY CODEDepartment of Community Affairs SN: 5049
F+5RVUA ENERGY EFFICI ci -{ ^� DN41��Nt3 nONSTFtN6T'ION
FORM 60OA-93 Residential Component Prescriptive Method A CENTRAL
-PROJECT NAME: M/Mrs. Rose !BUILDER:
-AND ADDRESS: !PERMITTING :CLIMATE
grlllel0B '• !OFFICE% St. Lucie Co:ZONE: 411 511 6: :
�OWNERz. !PERMIT NO. !JURISDICTION NO.661000
CK:
1, New construction or addition 1. New Construction
2. 'Single-+zn!.yr-detached or Multi.famthy attached 2. Single-Fami-l-y-
If Multifamily -No. of units 0
41 If Multifamily, is this a worst case (yes/no) 4. ___-
5. Conditioned floor area (sq.ft.) 5. 3130.00
6. Predominant eave overhang (ft.) 6. 1.00
7. Porch overhang length (ft.) 7. 8.00 __-_-
8. Glass area and type: Single Pane Double Pane
a. Clear Glass Ga. O.Osgft O.00sgft -___
b. Tint, film or solar screen 8b.489.0sgft 0.00sgft
9. Floor type and insulation:
a. Slab on grade (R-value, perimeter) 9a.R= 0.00 , 242.00 ft --__
k .Net Wall type area and insulation-
a. Exterior: 2. Wood frame (Insulation R-value) 10a--2 R=19.00, 2538.00sgft___
a. Adjacent: 2. Wood frame (Insulation R-•value) 10a--2 R•=11.00, 166.00sgft_.___
11.Cei.ling type area and insulation-
a. Under attic (Insulation R-value) ila.R=19.00 , 2066.00sgft____
12.Air distribution systems
a. Ducts (Insulation + Location) 12a. R= 6.00 , uncond
13.Cooling system 1:3. Type: Central A/C ____
EER: 10.00
14.Heating System: 14. Type: Strip Heat ----
COP: 1.00
15.Hot water systems 15. Type: Electric __--
EF: 0.90 ____
16.4ot Water Credits: (HR-Heat Recovery, 16. _-_-
DHP--Dedicated Heat Pump)
171infi.l.tration practice: 1, 2 or 3 17. 2
18.HVAC Credits (CF-Ceiling Fan, CV -Gross vent, 18. CF -_--
HF-Whole house 'ran, RB-Attic radiant
barrier, MZ-Muitizone)
19.EPI (must not exceed 100 points) 19. 90.27 -_---
a. Total As -Built points 19a. 55480.49
b. Total Base points 19b. 56459.38
-------------------------------------------------
--------------------------------
I Hereby certify that the plans and 1 Review of the plans and specifications
specifications covered by this calcu- : covered by this calculation indicates
Tion are in compliance with the 1 compliance with the Florida Energy
Florida Energy Code. 1 Code. Before construction is completed
C _ 1 this building will be inspected for
PREPARED BY: .._ a 1 compliance in accordance with Section
z=a_?_�_�3 553.908 F.S. : DATE._________
r hereby certify that this building is 1
in compliance with the Florida Energy !
Code. :
OWNER/AGENT:-----------------.--------- 1 BUILDING OFFICIAL:
DATE: : DATE:
---------------------------------
u INFILTRATION REDUCTION PRACTICE COI"PLIANCE CHECKLIST **
COMPONENTS
SECTION H_
REQUIREMENTS FOR EACH PRACTICE CHECK:
PIOCTICE #1
---------------------------------------------------------------------------------
606.1
COMPLY WITH ALL INFILTRATION PRESCRIPTIVES.
Windows
606.1
Maximum of 0.34 CFM per linear foot of operable sash
•
crack (includes sliding glass doors).
----------------------------------
Exterior &
606.1.
Maximum of 0.5 CFM per sq. ft. of door areas solid
Adjacent Doors
core, wood panel,insulated or glass doors only.
Exterior Joints
-----------------------------------------------------------------
606.1
To be caulked, gasketed, weather-stripped or other-
°_. Cracks
wise sealed.
PRACTICE #2
606.1
-------------------------------------------------------
COMPLY WITH PRACTICE 41 AND THE FOLLOWINGt
Ex terior Walls
606.1
- - ----------------------------------------------------
Top plate penetrations sealed. Infiltration barrier
& rloors
installed. Sole plate/floor joint caulked or sealed.
Exterior Walls
606.1
Penetrations, joints and cracks on interior surface
& Ceilings
-------------------------------------------------------------------------------
caulked, sealed or gask:eted.
DuctWork.
606.1
Ductwork in unconditioned space must be sealed.
Firepla.ces
606.1
----------------------------------------------------------
Equipped with outside combustion air, doors and flue
dampers.
------------------------
Exhaust Fans
606.1
•------------------------ -----
Equipped with dampers. Combustion devices see
---------------------------------------------------------------------------------
606.1.A.2.
Combustion
606.1
Be in unconditioned space (except direct vent), draw
Appliances
air from unconditioned space, exhaust to outside.
o
Cooking appliances shall be dampened and use
intermittent ignition.
0% OTHER PRESCRIPTIVE- MEASURES (must be met or exceeded by all residences.)
- -----------------P----------------------------------•----------------
Water Heaters
612.1
Comply with efficiencyrequirements in Table 6-1:.
Switch or clearly marked circuit breaker (electric)
or cutoff (gas) must be provided. External or built-
in heat trap required.
-_A---------------------------------------------------------------------
Swimming Pools
612.1
Spas and heated pools must have covers (except solar
& Spas
heated). Non-commercial pools must have a pump timer.
°
Gas spa & pool heaters must have a minimum thermal
efficiency of 78 percent.
o------------------------------------------------------------------------------
Shower Heads
612.1
Water flow must be restricted to no more than 3 gal-
----------------------------------------------------------------------------------------
-
lons per minute at 80 PSIG.
HVAC Duct 610.1 All ducts, fittings, mechanical equipment and plenum
Construction chambers shall be mechanically attached, sealed, ins -
Insulation & ul.ated and installed in accordance with the criteria
Installation of Section 610.1.ABC.2 & 610.1.ABC.=.. Duct in attics
must be insulated to a minimum of R-6. Air handlers
shall not be installed in attics unless in mechanical.
closet.
__---e--- �y---'--------'-----------------------------------------------------------------
Insulation 604.1 Ceilings minimum R-19.-Common Walks - Frame R-11 or
602.1 CBS R-3 both sides. Common ceiling & floors R-11.
�#�>� ���� ;< �-:� ;��*x�x���#max#��Fx��#��� w #��x �;-#�� x �# x•����#### x x-��t 3t��es��tt��x*��##�� x• �#,Y
BASE __= 1 -_= AS -BUILT
GLASS----------------- 1
(LIEN AREA x BSPM = POINTS 1 TYPE SC ORIE.N AREA x SP'M x SOF = POINTS
---------------------------------------------•---
a 89.00 82.2 7315.8 1 SOL TINT N 20.0 51.5 .98 1006.6
' SGL LINT
N
9. 11
01.0
a 98
451.9
1 SOL
TINT
N
20.0
51.5
.94
972.8
a
1 SGL
TINT
N
20.0
51.5
.96
987.1
1 SOL
TINT
N
20.0
51.5
.95
970.5
E 183.00 82.2
15453.6
1 SOL
TINT-
E
36.0
107.1
.95
3677.1
1 SOL
TINT
E
6.0
107.1
.68
439.3
1 SGI_
TINT
E
20.0
107.1
.80
1715.2
1 SOL
TINT
E
63.0
107.1
.52
3.` 08. 6
1 SOL
TINT
E
63.0
107.1
.52
508.6
S 32.00 00 82.2
2630.4
1 SOL
TINT
S
16.0
98.3
.88
1382.3
1 SOL
TINT
S
16.0
98.3
.91
1426.0
®4 180.00 32.2
14796.0
1 SOL
TINT
W
40.0
107.1
.52
2227.7
1 SOL
TINT
W
72.0
107.1
.52
4009.8
1 SOL
TINT
W
20.0
107.1
.80
1715.2
1 SOL
TINT
W
20.0
107.1
.80
1715.2
1 SOL
TINT
W
8.0
107.1
.75
643.4
1 SOL
TINT
W
20.0
107.1
.80
1715.2
.15 x COND. FLOOR / TOTAL
GLASS = ADJ.
------------------------------------
x GLASS
= ADJ GLASS
1
GLASS
AREA
----------------------------------------------------------------------------------
AREA
FACTOR
POINTS
POINTS
1
POINTS
. 15 3,130.00
489.00
.960
40,195.00
3S,592.90
1
32,030.41
NON GLASS------------
1
° AREA ., BSPM =
POINTS
; TYPE
R-VALUE
AREA
x SPM
= POINTS
WALLS-----------------
;
--------------
---------
----------
EA 2530.0 1.0
2538.0
1 Ext
Wood
Frame
19.0
1649.0
1.00
1649.0
1 Ext
Wood
Frame
19.0
999.0
1.00
889.0
Adj 166.0 .7
116.2
1 Adj
Wood
Frame
11.0
166.0
.70
116.2
DOORS ----------•----------
1
Ext 20.0 4.8
96.0
Ext
Wood
20.0
7.20
144.0
Adj 18.0 1.6
28.8
1 Adj
Wood
18.0
2.40
43.2
CEILINGS -------•----------
1
UA 2066.0 .6
1239.6
1 Under Attic
19.0
2066.0
1.10
2272.6
°
1
FLOORS----------------
1
Slb 242.0 -31.9
-7695.6
1 Slab
-on -Grade
.0
242.0
-31.90
-7719.8
0
1
INFILTRATION----------
31:0.0 10.9
.34117.0
1 Practice
#2
3130.0
10.90
34117.0
----- --------------------------
TOTAL SUMMER POINTS
-----------------------------------------------
1
69,032.90
1
635591.61
TOTAL x SYSTEM =
COOLING
1 TOTAL x
CAP x DUCT
x SYSTEM x CREDIT
= COOLING
SUM P•TS MULT
POINTS
1 COMPON
RATIO MULT
MULT
MULT
POINTS
19. 04? _ 9Ci _ 77 0554917
! AT - S91
_ A l
i on i fi7i i-----A
--
-AAp An
IQ 00R 70
WINTER CALCULATIONS
EASE ___ ; __= AS -BUILT
GLASS ---------------- 1
ORIEN AREA x BWPM = POINTS 1 TYPE SC ORIEN AREA x WPM x WOF = POINTS
-1-----------------------------------------------------------------------------
N 89. 00 -3.4 -302. 6 1 SGL TINT N 20.0 9. 6 1.01 194.2
SOL
PINT
N
9.0
9._6_-_1.01
87.5
SGL
TINT
N
20.0
9.6
1.03
197.3
SGL
TINT
N
20.0
9.6
1.02
196.0
1
SGL
TINT
N
20.0
9.6
1.02
196.8
E 188.00 -:.4
-639.2
1
SGL
TINT
E
36.0
-2.0
.73
-52.7
1
SGL
TINT
E
6.0
-2.0
-.76
9.1
1
SGL
TINT
E
20.0
-2.0
-.08
3.4
;
SGL-TINT
E
63.0
-2.0
-2.03
255.8
1
SGL
TINT
E
63.0
-2.0
-2.03
255.8
S. 32.00 -3.4
-108.8
1
SGL
TINT
S
16.0
-10.2
.93
-151.2
1
SGL
TINT
S
16.0
-10.2
.95
-154.6
W 180.00 -3.4
-612.0
;
SGL
TINT
W
40.0
-2.0
-2.03
162.4
w
1
SGL
TINT
W
72.0
-2.0
-2.03
292.3
1
SGL
TINT
W
20.0
-2.0
-.08
3.4
1
SGL
TINT
W
20.0
-2.0
-.08
=:.4
1
SGL
TINT
W
6.0
-2.0
-.36
5.8
1
SGL
TINT
W
20.0
-2.0
-.09
3.4
.15 x COND. FLOOR / TOTAL
GLASS
=
ADJ.
- ---------•--------------------•
x GLASS
ADJ GLASS
GLASS
AREA
-------------------------------------------------------------------------------
AREA
FACTOR
POINTS
POINTS
i
POINTS
.15 3,130.00
489.00
.960
-1,662.60
-1,596.30
1
1,507.98
NON GLASS------------
1
♦ AREA x BWPM =
-------------------------------------------------------------------------------
POINTS
1
TYPE
R-VALUE
AREA
x WPM
= POINTS
WALLS-------------_---
1
@xt 2538.0 1.1
2791.8
1
Ext
Wood
Frame
19.0
1649.0
1.10
1813.9
1
Ext
Wood
Frame
19.0
899.0
i.10
977.9
Adj 166.0 1.8
298.8
1
Adj
Wood
Frame
11.0
166.0
1.80
296.8
DOORS----------- ------
Ext 20.0 5.1
102.0
1
Ext
Wood
20.0
7.60
152.0
A&q 18.0 4.0
72.0
1
Adj
Wood
18.0
5.90
106.2
CEILINGS--------------
1
Uk 2066.0 .6
1239.6
1
Under
Attic
19.0
2066.0
1.01
2066.0
JLOORS---------------
1
Slb 242.0 --1.9
-459.8
1
Slab
-on -Grade
.fit
242.0
2.50
605.0
,INFILTRATION----------
1
3130.0 4.1
12833.0
1
Practice
42
3130.0
4.10
12833.0
TOTAL WINTER POINTS
1
15,
281. 10
1
20,360.78
------ -------------------------------------------------------------------
TOTAL x SYSTEM =
HEATING
1
TOTAL
x
CAP x DUCT
x SYSTEM
x CREDIT
= HEATING
WIN PT,S, MULT
POINTS
COMPON
RATIO MULT
MULT.
MULL-
POINTS
----;-------------------------------------------------------------------------
1s-^Ri-1t1 115 IX_Rnp-91
!
on
7An-7R
1 no 1
n7n i
non 1
non
91 7MA W
BASE __= AS -BUILT
NUM OF MULT = TOTAL 1 TANK VOLUME Ef= TANK x MULT x CREDIT TOTAL
YEDRMS ; RATIO MULT
------------------------------------------
4 3527.0 14,10B.00 40 .90 1.000 3449.7 1.00 13,79S.67
Y SUMMARY
_-= BASE __'- __= AS -BUILT
------------------------
----------------------------------------------
COOLING HEATING HOT WATER TOTAL 1 COOLING HEATING HOT WATER TOTAL
POINTS + POINTS + POINTS = POINTS 1 POINTS + POINTS + POINTS = POINTS
-------------------------------------------------------------------------------
25542.2 16809.2 14108.0 56,459.38 1 19895.8 21786.0 1.3798.7 55,480.49
EPI = 98.27 #
_r__cr- aer.all.e=❑ intorma�ion
of the EPI rating number
or for any ITEM listed,
Ask_your Builder for
DCA Form 60OA-93
or Form 60OD-93
0 10 20 30 40 50 60 70 80 90 100
------------------------------------------- --- X - 1
TRe maximum -allowable EPI is 100. The lower the EPI the more efficient the home
RESIDENTIAL ENERGY PERFORMANCE RATING SHEET
0
ITEM HOME VALUE Low Efficiency High Efficiency
SINGL CLR DBL TINT
WINDOWS ..................... Single Tint I ------ X-------------- I
INSULATION ..................
R-10 R-30
Ceiling R-Value.........
19.0
:--------- X-------------
`
R-0 R-7
Wall R--Value.........
18.5
: ----------------------- XI
Floor R-Value.........
0.6
IX --------------------I
AIR CONDITIONER .............
10.0 SEER 17. i;
SEER/EF-R..................
10.3
9.7 EER 16.0
HEATING SYSTEM ..............
2.50 COP 4.19
Electric COP/HSPF........
1.0
IX -------------------- 1
0.78 AFUE 0.90
Gas AFUE............
0.00
I---------------------i
r
WATER HEATER ................
>.88 0.96
Electric EF..............
0.90
f---- X-----------------I
0.54 0.90
Gas EF..............
0.00
;---------------------:
0.40 0.8()
SolarEF..............
1---------------------I
C'THER FEATURES ..............
14certify that these energy saving features required for the Florida
Energy Code have been installed in this house.
Bui 1der
Address: -----Signatures----__-----.--__----------Date:
city/Zip -----------------------
Florida Energy Code for Building Construction - 1997.
Florida Department of Community Affairs FL-EPL CARD93,