HomeMy WebLinkAboutFORT PIERCE FARMS WATER CONTROL DISTRICTr r FORT PIERCE FARMS WATER CONTROL DISTRICT Office of the District Engineer 2222 Colonial Road, Suite 201 Fort Pierce, Florida 34950 Telephone: (407)461-2450 Fax: (407)465-1225 M E M O R A N D U M TO: etch Milxl�s FROM: Dick Hellstrom ? DATE : May 2 0 , .- 19 9 3 - : ------------- -------------------;-------------------- SUBJECT: Permit Application No. 0027, Submitted by Timothy and Debra Rose, for a Culverted Crossing in Canal No. 6 This application correctly identifies the design flow as 95 cubic feet per second, as I discussed with Mr. Rose over the telephone recently, based upon his representation that the culvert would be located approximately one -quarter mile (1,320 feet) south of Russos Road. This would be a drainage area of 0.625 square miles. However, the drawing attached to the application indicates the location to be 2,272 feet south of an unnamed road, which appears to be Russos Road. If this is the true location, then the drainage area would change to 0.71 square miles, resulting in a design flow of about 105 cubic feet per,second. Evaluation of each case described above is based on the District's criteria of a maximum allowable head loss (including entrance and exit losses) of 0.3 feet, and values of "n" for corrugated metal pipe of 0.024 and for'reinforced concrete pipe of 0.012. -r In either case, the required corrugated metal pipe"'size would be one 84-inch diameter -pipe. However, the Board has the latitude to waive its criteria in cases where a hardship,, might exist or where e;;:tenuating circumstances should be 'considered.- Therefore, the possibility may exist that the Board would consider accepting a 72-inc1rdiameter culvert at this location, but it wouldrequire Board action. I could'support �✓ the 72-inch diameter culvert alternative, provided the invert /3 elevation is set at an elevation not higher than +13.5 NGVD, or at the elevation of the existing canal bottom, whichever is lower. L The application requests permission to install a 66-inch diameter culvert, which is unacceptable. z s iWP:Canal46.001 t 'i r A. Name: Address: �1 'e 4i _ � l ... ®O , 2 0 - FORT PIERCE"FARMS WATER CONTROL, DISTRICT ("District") 131 Nor�Second Street, Room 2I2 Fort Pierce; Florida 34950 (407) 464-0939 Application for Connection to or Use of District Facilities* r Telephone Number: "/O 7- 7 7 (0—IIFR 4 B. Proposed Connection or Use: (Check appropriate box) ❑ Culvert connection to District canal for irrigation or gravity drainage " ❑'Pump connection'to`District'canal^for irrigation LEI Installation of culvert or water control structure in District canal for crossing or water control ❑ Other (specify): C. Location: 'Section: Township: Range: Canal No.: 16 Area served: • 190S_ 41.4 acres D. Construction Schedule: ; } Estimated commencement date: - a t 4%7_ 'i Estimated completion date: F. Special Conditions: ACKNOWLEDGEMENT AND ACCEPTANCE: I hereby certify that the information shown above is accurate to the best of my knowledge, and that I am obligated to satisfy all Standard Provisio s and Special Conditions imposed by the District: Landowner's Signature: �v Landowner's Name (type or print) ;27;2, n Cn.4e Date: . Y7- 9 F If Applicant is not the Owner: I hereby certify to the statement above, and also that I am authorized by the Landowner to act as his agent in obligating him, his successors and assigns in this matter: Signature: Name (type or print): Title or Position: i Date: Application Approved and Permit Issued: For the Fort Pierce Farms Water Control District Date of Approval: L {?L W 710 /LiGJ Permit Expiration Date: ��� / *This Application will become a Permit if and when approved and signed by an authorized repre- sentative of the District. FORT PIERCE FARMS WATER CONTROL_ DISTRICT ("District") Application orUonnectton tto or Use of District STANDARD PROVISIONS for Application/Permit No. Oo 27 If this Application for a Permit is approved; Ldo acknowledge; understand, and agree that: 1. I hereby indemnify an&hold the District harmless from claims for property damage or personal injury arising-fromr= the installation or use of the permitted facility, and that this indemnification extends to damage to the facility itself that may occur from District operation and maintenance work 2. If this Application/Permit is,for a drainage connection; then drainage discharge from the area served shall not exceed the volumetric equivalent of 2.6 inches of depth over the area for any 24-hour period (50 gallons per minute per acre) from the 10-year frequency, 72-hour duration rainfall. 37, -Approval of this application'does-not rel4ve the Permittee frb -securing any and,,all-other permits.that-maybe. required by other entities or governmental agencies, including, but not limited to, the South Florida Water'Manage- ment District, the Florida Department of Environmental Regulation, and St. Lucie County. 4. The Applicant, his agents and contractors, shall conduct the work in a manner that will not impair the use, orpoten- tial use, of the District right-of-way and facilities. In' no case shall drainage or irrigation canals or appurtenant works be obstructed or restricted. 5. The use of, or construction within, the District's right-of-way shall conform to the details of the attached approved drawings supporting this application. If modifications are desired, those modifications must be. approved by the. District in writing, prior to construction. 6. If a permit is granted,I, shall notify the District at the beginning and completion of the work, enabling the coordin- ation and scheduling of inspections. p - - 7. All installations shall be clearly marked with a post of contrasting colors to identify the location and extent of the permitted :installation. 8. Within fifteen (15) days of completion of the work, I shall submit a statement to the District certifying that the work was performed in accordance with the permit and the approved drawings. If the work deviates from the permit or approved drawings, the certification shall state the nature and extent of those deviations. 1 9. I accept total responsibility for any erosion of, or shoaling in, the District's right-of-way or canals that results' from the permitted work, and I shall repair or remove same promptly, at -no expense to the District. 10. D'uring and after construction, I shall. prevent material from the, construction area from being discharg-ed to, or set---' tling in, District canals. -` 11. If a perm+it is issued fora: hydraulic connectionlof my property wit' a District canal, I shall not discharge hyacinths or other aquatic vegetation into the District canal. 12. Unless authorized by permit, I shall neither place, construct or plant, nor cause to be placed, constructed or planted, any object or improvement within the. District right-of-way without the express written prior approval of the: District. 13. If required in the interests of the District's operation and maintenance program, or by any modifications to the District's Standard' Provisions, I agree to alter, replace, relocate, or remove the permitted facilities at no cost to the District, all as is more fully set.' forth by District Policy Resolution duly recorded in O.R. Book 673,at-page 224 of the public records of St. Lucie County, Florida, but subject to the limitations thereof. 14. The 1'andsto be benefited by this application are, or may be, subject toflooding during periods of high water resulting from heavy rains or other acts of God, and the permit will be accepted subject to this possibility, which is recognized not to be within the control, of the District. 15. Any other requirements that may be imposed by the District are, binding upon me, my successors and assigns. 16 Any permit issued as an approval of this application other than one issued in irrevocable, recordable form pursuant to the Policy Resolution referenced in item 13, above, shall notbe transferable from the applicant/permittee to a subse- quent owner or owners of all; or.a portion of, thesubject property without the express, writtenapproval of the. District. ACKNOWLEDGEMENT Signature: f��-� .Date: _G17— 5;"-7 Culvert Length is Dependent on the Depth of Canal that is Crossed and Crossing Width Desired by Applicant Crossing Width I Top of Slope Determined by Applicant 2' Alin. �1=u1 lu=r/J=/u;Jrl=1n-1L I Cover I 2 min _ 2 Canal esign irl I —Bottom II'—I� ECulvert— — l ill i _)ll_11)=11i_N1-1i1 ;IU�111�I1J�rU _Ill= A co—i SECTION B-B N.T.S. NOTES: 1.) Concrete or sand —cement endwalls may be used to shorten the culvert length. All work shall be in accordance with Florida D.O.T. specifications. 2.) All disturbed slopes, berms and other areas shall be seeded, fertilized and mulched (or sodded) in accordance with Florida D.O.T. specifications. 3.) Drainage shall not be blocked or impaired at any time. FF9W CD 4,64-o939 4.) The applicant shall notify thePjg[=RWGD office ( 4 6 1 5958) 24 hours prior to construction of the crossing. Canal R/W Slope Berms Away From Canal =11 L=111 clrl�. /�V 1=)Il_ 111 -1rlc 111=11I =l11=Ill— �,_ Backfil and Compact ,.�' L— 60 Alin. Typical Design Canal Section a Indicate Location of 1 I NN 2 Pro osed Improvement below; NW 1/1 I NE 1/4 Stt 1/4 I SE 1/4 � lrlr 111 Crn B SECTION i 2 Center Culvert in Canal A —A N.T.S. it l=)11= FORT PIERCE FARMS WATER CONTROL DISTRICT SKETCH TO ACCOMPANY CULVERTED CANAL CROSSING IDATE: I NUMBERA: ' SEC. TIP. — RUE. VICINITY PLAN CANAL NO.: APPLICANT: EXHIBIT "B" /