Loading...
HomeMy WebLinkAboutASD (ALUMINUM SCREEN DESIGN) PAPERWORKjr;�- FILE CONY' '3Qk RE` 0G Al..minum d Consiruc�+an Ena+veering *01'an T -es: Yp_ n - ❑ Screen Room ❑Sun Room ❑Fill In ' ❑ Pool Screen/Cage (Non -Removable Screen — Designed to withstand actual Wind Speed) ✓❑ Car Port ❑Patio Cover ❑Other: *Project Address: 2971 rogers road : fort pierce fl. 34981 Contractor Name:john gizzarelli / atlantic xteriors *Address:407 s.e. cork road *City: port saint lucie fl. *Zip Code: 34983 *Phone/Fax: 772-370-2499 12/26/2018 _ SC REVIEWED ORCOM IAOEGUSI N St �4c ej.NFQ DATE REVIEWED BYTY a T Q Cou PLANS AND PERMIT BE KEPT ON ]C38 SITE OR NO INSPECTION(S) WILL BE MADE *Email: gizzman70@gmaii.com *Choose OneRIMail ❑Pick Up ❑E-File ❑Fed Ex/UPs* 3 # of Copies ❑Single PDF ❑ Each Page Separate `(For FedEx option go to www.aluminumscreendesimt corn and provide FedEx/UPS account #) * Payment: ❑Check OCredit Card* *(For Credit Card option go to -vvww.aluminumsereendesign.com to pay by credit Engineering prepared by: s 4YFESe6EPLANSANDALLP±REOPOsEDWORK-DBC"OWECTIONS MEpUWR CTORSTHAT F NEC IN 4ADER TO COMiN &T#I LIOAHLE CODES, Engineer: Michael Thompson, MSc, P.E. (P.E. # 47509) 4401 Vineland Road- Suite A6 Orlando, FL 32811 Ofrice:407-73471470 Cell: 407-721-2292 Project Manager Paul Thomas 386-479-9504 Fax: 888-923-8181 Email: aluminumscreendesianla�vahoo com Website: www.aluminumscreendesign.com cA#30930 ME] A q R11 '* 5 xa'FiAWMm nl;m Construction Eng.n..erir,4 Ultimate Wind speed (mph)'150 Exposed Category' C Risk Category: 1 Screen Room ❑Sun Room ❑ FHI In ;_ ❑ Insulated ❑Pan Roof ❑ Gutter ❑Fascia ❑Block wall ❑Conventional Wall ❑ O Wall Uprights X Top Plate X Chair Rail X Uprights X Top Plate X Chair Rail X Kick Plate i Pool Screen/Cage: ❑ Dome ❑Gable ❑Mansard/Hip ❑Shed/Slope ❑ Gutter ❑Fascia ❑Block Wall ❑ Conventional Wall Beams X Uprights X Purlin _X —Chair Rail X Beams X Uprights X Purlin X Chair Rail X Kick Plate _❑ Patio Cove_ r `Y ✓❑ Car Port-; ❑ Insulated v J❑Pan Roof ❑ Gutter ❑Fascia ❑Block Wall Beams 2 X7 Post 4 X4 ❑Conventional Wall ❑✓ 4th Wall ;Concrete`: ❑ Existing ❑ New: 4"Slab ✓❑Pier ❑Ribbon Footer X, Pavers ❑6" Thickened Edge Other:4x4 posts are going in a 24"xMW4" hole with rebar going through 4x4 posts hole getting filled with concrete Note: In the event that there is a conflict with the design plans and general notes and design standard, the contractor shall utilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or construction between the plans and the general notes and design standard. Engineer: Michael Thompson, MSc, P.E. (PE#47509) 4401 Vineland Road Suite A6, Orlando, FL 32811 (CA#30930)-Ph 407-734-1470/Fax 407-734-1790 Em- On AS ALUMINUM SCREEN DESIGN AIUm(num 3 Consf.[uction En97.neerinm General Notes & Design Standards - (Unscreened Patio Room Enclosure) The following are general design standards. More stringent design standards may be noted on the plans. In the event of a conflict in plans and/or design standard dimensions and/or member sizes, the contractor must utilize the more stringent dimensions and/or member sizes prior to ordering materials, fabrication and/or construction. Design Codes: Florida Building Code 2017 (6' Edition) Aluminum Design Manual 2015 ASCE 7-10 Design Loads: Pursuant to FBC Chapters 16 & 20 Ultimate Wind: -150 MPH (FBC Table 2002.4) (45 psn Risk Category: -See attach site specific plan sheet (FBC Table 1604.5) Exposure Category: -See attach site specific plan sheet (FBC 1609.4.3) Additional Load requirements. Structural members supporting screened enclosures are designed for wind in both of two orthogonal directions using the pressures given in Table 2002.4. Each primary member is also designed for a 300 pound load applied vertically downward along any 1 foot of any member, not occurring simultaneously with wind load. In addition to wind pressures, purlins is also be designed for a 200 pound load applied vertically downward along any I foot of any member, not occurring simultaneously with wind load. Design Basis: Allowable Stress Design (ASD) =Allowable Strength Design (ASD) divide by safety factor General Requirements: Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies acceptance of information shown as correct and obligates himself to any expense, real or implied, arising from their use. A change to the structural drawings due to the acceptance of alternates and/or substitutes is the responsibility of the contractor and must be submitted to the engineer for approval. The general contractor and each subcontractor shall review the approve construction plans in its entirety and verify all existing conditions prior to the start of any work. All inconsistencies shall be reported to the designer and/or structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans prepared by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the review and approval from the designer and/or structural engineer. Then designer and/or structural engineer shall bear no responsibility or liability for the construction of premises and accuracy of the drawings. Foundation and Earthwork: Applicable only when unsuitable soils are encountered. When unsuitable soils are encountered as specified bearing strata, notify owner's representative/engineer. Soil bearing capacity — 2,000 psf Minimum Provide neat excavation for footing and place concrete immediately after excavation and inspection. Pump water from footing excavation if greater than one inch. Compact all fill to 95% ASTM D698 density. Unit soil weight =105 pcf Internal angle of friction = 30 degrees Coeff. Of friction between footing and soil = 0.5 Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com ALUMINUM SCREEN DESIGN OHM D.a ivminum 8 Cc nsirvc Non Emp fneerlr.p Structural Aluminum: Conform to latest edition of Florida Building Code and Aluminum Design Manual standard practice for aluminum design. All aluminum shall be 6005-T5 (E=10,000 ksi; Fy = 35 ksi) with a minimum wall thickness of 0.046" Splicing prohibited without prior approval as to location and type. Burning of holes in aluminum members is prohibited. Any member with burned holes must be replaced. Aluminum Protection: Shall be pursuant FBC 2003.8.4. Aluminum surfaces in contact with dissimilar materials, lime -mortar, concrete, or other masonry materials, shall be protected with powder coated or ESP paint or alkali -resistant coatings, such as heavy -bodied bituminous paint or water -white methacrylate lacquer. Screws: Aluminum self -tapping screws shall conform to ASME B18.6.4 specification. Self —tapping screws shall meet the requirements of ADM J.5 Maximum fastener spacing shall not exceed (3+20t) where "t" is the member thickness.in inches. For roofing and siding connection, use minimum 412 screws for end and -side laps -spaced -at 12" max for side lap and end lap fasteners shall be no more than 2" from the end of overlapping sheets. For bottom plate and column base, secure with '/." tapcons a minimum embedment of 1 1/8" and 2 Y." respectively into concrete footer. Bolts: Bolts and other fasteners shall be aluminum, stainless steel, hot -dip or electro-galvanized steel. Double cadmium plated steel bolts may also be used. Bolt holes diameter shall not exceed 1/16" larger than the bolt diameter and shall be spaced at a minimum of 2.5 times the bolt diameter with minimum edge distance of 1.5 times the bolt diameter. Bolts shall meet the requirements of ADM J.3 Concrete Conform to ACI 318, latest edition and ACI 301 Compressive Ultimate Strength (Minimum at 28 days) shall be 3000 psi Exposed chamfer edges shall be'/e" Reinforcine Steel: Conform to ACI 318 and 315, Latest edition All reinforcement steel shall be ASTM A615 Grade 60. Smooth dowels & ties shall be ASTM A185 Welded Wire Fabric shall be ASTM A185 or A82 (Flat sheet). Deformed bar anchors shall be ASTM A496, Grade 70 Cover: Footing 3" Washer: Washers shall be used under bolt heads and under nuts. Hole Alienment• Poor matching holes must be rejected. Contractor shall prevent holes from drifting and distort the metal. All chips and foreign matter between contacting surfaces shall be removed before assembly. Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com ® ALUMINUM SCREEN DESIGN - E E91 AS Aluminum I Gonsiruciion Engineering Beams & Uoriehts: ' In the event of a conflict with the values in this table and the site specific plan, the contractor must utilize the more stringent dimensions and/or member sizes between the site specific plan and the below applicable span limitations prior to ordering materials, fabrication and/or construction. 150 MPH PRIMARY HEADER BEAM MEMBERS -OPEN COVERED PATIO -(No Screen Insert) SIZE 3" Insulated Roof Span Maximum Roof Span = 6'-0" 3" Insulated Roof Span Maximum Roof Span = 8'-0" 3" Insulated Roof Span Maximum Roof Span = 10'-0" 3" Insulated Roof Span Maximum Roof Span=12'-0" 3" Insulated Roof Span Maximum Roof Span =15'-0" 2 X 4 9'-0" 9'-0" 8'-0" 7'-0" 7'-0" 2 X 5 12'-0" 11'-0" 10'-0" 9'-0" 8'-0" 2 X 6 '13'-0" 12'-0" 11'-0" il'-0" 10'-0" 2 X 7 15'-0" 14'-0" 13'-0" 12'-0" 11'-0" 2 X 8 15'-0" * 15'-0" 15'-0" 15'-0" 13'-0" 2 X 9 15'-0" * 15'-0" * 15'4" * 15'-0" * 13'-0" 2 X 10 15'-0" * 15'-0" * 15'-0" * is. -On * 13'-0" Column size is 3 x 3 x 0.125" (1/8") unless noted otherwise with a max height of 9'-0" !(CSR) control < 1.0. Larger span rect larger column size. Knee Bracing: Contractor shall provide knee bracing on 45 degree angle pursuant the attach detail sheet that specified size and length requirements. Knee bracing on upright above super gutter intersection shall be connected to upright no more than 6" above the super gutter. Knee brace size shall be a minimum of 2 x 2 for beam span of 15' max; 2 x 3 for 30' max; 2 x 4 for beam span greater than 30'. Intermediate/Header Beam: - Contractor is required to install a minimum 2 x 7 intermediate header beam supported with 3 x 3 column spaced at 10 feet (max) when insulated roof span exceeds IS feet. Patio Cover: Contractor is required to install insulated roof covering pursuant to the Florida product approval specification. Overhang shall be a maximum of l'-0" along the side, 3'-0" along the front and 1/2" along the front interface between the super gutter and the attached pool cage knee riser wall. Maximum deflection shall be limited to L/80. Edee Distance: Contractor is required to install uprights to provide a 2" minimum clearance from edge of slab and/or footer. Michael Thompson, P.E. #47509/CA#30930 4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790 www.aluminumscreendesign.com h6u6-' addr�55 X771 Rogers Road, ForPir°re& FL, 3` ?gl (D�SPan 3�t-�'carr� clium,i�Km�^oo�, Ota�{ V, os ec �k IX 7 cam rr br°arn Rah A Zt- a 0 K7 c orrrror broom, I IN 31� La, -1 ea ALUMINUM SCREEN DESIGN ROLL FORM GUTTER IS ATTACHED TO 3" PAN ROOF WITH #10 1" 6" FROM ENDS 24" ROOF IS ATTACHED TO FRONT WALL & SUPPORT BEAM WITH (4) #10 1" TX TX THOLE FILLED WITH 3000PSICONCRETE ALUNIINUMSCREENDESIGN.COM ALUMINUMSCREENDESIGN @YAHOO.COM PHONE: 407-734-1470 FAX: 407-734-1790 ROLL FORM FASCIA IS ATTACHED TO PAN ROOF WITH #10 1" 6" FROM ENDS 24" O.C. 4X4 POSTS ARE ATTACHED TO 2X7 BEAM WITH 2 3/8" X 4 1/2" POST IS SET WITH 18" #5 REBAR INTO CONCRETE GRADE DESIGN STATEMENT METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-175 ALL TAPCONS SHALL PROVIDE MINIMUM OF 11/8" CONCRETE EMBEDMENT DEPTH THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 150 MPH (FOR 3 SECOND GUSTS) NOMINAL SPEED 117 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY I. CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL. PURCHASE, FABRICATION AND CONSTRUCTION CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS 4401 VINELAND.ROAD r .,$UITE A6 ORLANDO FL 32811 �P E. # 47509 'S CA#309N J