Loading...
HomeMy WebLinkAboutREVISIONSOFFICE USE ONLY: DATE FILED: 8/20/19 REVISION FEE: $75.00 PERMIT # 1901-0052 RECEIPT # � 05 4$a3 PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT PROJECT INFORMATION LOCATION/SITE ADDRESS: 12103 RIVERBEND DR PORT ST LUCIE, FL 34984 y7 W DETAILED DESCRIPTION OF PROJECT R4 SCANNED REVISIONS: BY Change from MI door To Custom FL14850.1 FD-8750 Impact L+} Lucia _ „ wunty CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: SCIENTIFIC CONSTRUCTION GROUP INC QUALIFIERS NAME: RAPHAEL H HENRI ADDRESS: 1251 NE 209 TERRACE CITY: MIAMI STATE: FL PHONE (DAYTIME): (786) 587-9728 OWNER/BUILDER INFORMATION: NAME: NOEL PEREZ FOUNTAIN PLAZA INVESTMENT LLC 12103 RIVERBEND DR CITY: PORTSTLUCIE PHONE (DAYTIME: STATE: FL ARCHITECT/ENGINEER INFORMATION: NAME: Paul welsh ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9/23/09 Revised 06130117 STATE: ST. LUCIE CO CERT. #: ZIP: 33179 FAX: (305) 654-8779 FAX: FAX: ZIP: 34984 ZIP: Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 09/28/2017 09/29/2017 10/02/2017 12/12/2017 FL # Model, Number or Name Description 14850.1 FD-8750, Impact. FD-8750 French Door, SD-87Gb Swing Door, SLT-8710 Sldelite, Impact. _ Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL14850 R3 II CWS-641C.Ddf Approved for use outside HVHZ: Yes Verified By: Lucas Turner 58201 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: +70/-70 Evaluation Reports Other: Large Missile French Door w/ Sidelights, Max. French FL14850 R3 AE EvaIpeooft641C.pd Door 6' x 8', Max. Single Door Tx 8', Max. Sidelight Tx 8', DP Created by Independent Third Party: Yes +/- 70 psf. Glass compiles to ASIM E1300-04. Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 85OA87-1824 The State of Florida Is an AA/EED employer. Qlattight 2007-2013 State of Florida, :: Pdvagy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public,recoms request, do not send electmonic mall [p this entity. Instead, contact the office by phone or by lmdltional mail. If you have any questions, please contact 850.481. 1395 rsua SeNon 455.2]5(1 all to Statutes, effective October I, eo office licensees licensed under Chapter 456, F.S. must provide the Department with an emal If ve one. The email provided may be used for official communication with the licensee. However email addresses are public record. Ifyou do notw pp onal address, please provide the Department with an small address which can be made available to the public To determine if you are a licensee u a F please click Iles Prafta Approval Accepts: ®�®� o ,�����J� Credit r SaCard L 0 �G® ®� ............. ®� �0 SWING DOOR & SIDELITE - LARGE MISSILE IMPACT 375/8' MAX PANEL WIDTH 26 618' GLASS DLO /V' MAX FRENCH DOOR WIDTH 17. AAX NIT !EIGHT C 9M78'AX X X PANEL HEIGHT 84 3/16' GLASS SEE DLO NOTE4 G A 11 FRENCH DOOR TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS ........ 1-3 GLAZING DETAILS....................................4 SECTION VIEWS....................................5-7 BO M............................................................8 EXTRUSIONS.............................................0 ANCHOR SCHEDULE & NOTES ...... ....... 10 INSTALLATION DETAILS .................... 11-12 t C In Mw SINGLE DOOR GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED l-kwft110U0006 TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC), CURRENT I WINDOW SYSTEMS EDITION INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AND I 1900 SW 44TH AVE. IS RATED FOR WIND ZONE 4 MISSILE LEVEL D IMPACT USE AS DEFINED I OCALA, FLORIDA 34474 IN ASTM E 1996 PER THE FBC. W W W.CWS.CC 2. GLAZING OPTIONS: (SEE SHEET 4) 3. CONFIGURATIONS: SINGLE OUTSWING, SINGLE OUTSW ING W/SIDELITE(S), FRENCH DOOR(S), FRENCH DOOR(S) W/SIDELITE(S), SIDELITE NOT ATTACHED. 4. LOCK OPTIONS: UP TO 6'8': A DOUBLE BORE WRWO (2) INTERIOR FLUSH BOLTS. HANDLE SET @ 36' B. MORTISE LOCK w/ TWO (2) INTERIOR FLUSH BOLTS. HANDLE SET @ 34- C. MULTIPOINT (4 PT.) HANDLE SET @ 34- ABOVE 6'8': A. MULTIPOINT (5 PT) HANDLE SET @ 34- 6. DESIGN PRESSURE RATING- -NEGATIVE DESIGN LOADS BASED ON, TESTED PRESSURE AND GLASS TABLES ASTM E-1300-04801/09. -POSITIVE DESIGN LOADS BASED ON, TESTED PRESSURE, WATER INFILTRATION TEST PRESSURE AND GLASS TABLES ASTM E-1300-04801/09. 6. ANCHORAGE: THE 33 173%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEETS 11-12 FORANCHOR DETAILS. WINDLOAD DURATION FACTOR CE=1S WAS USED FOR WOOD ANCHOR CALCULATIONS. 7. PRODUCTS APPROVED FOR IMPACT RESISTANCE. SHUTTERS ARE NOT REQUIRED. 8. ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER. PANELS ARE PROCESSED AND ASSEMBLED VIA TIE ROD. 9. SERIES/MODEL DESIGNATION SD-B700, FD-8750, SLT41710. 10. THE DESIGNATION XAND 0 STAND FOR THE FOLLOWING: X= OPERABLE SASH, O = FIXED SASH 11. SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS IN A SIMILAR LOCATION. 12. INTERIOR FLUSH BOLTS ON ACTIVE PANEL TO BE ENGAGED PRIOR TO SEVERE W EATHER. 13. QUALIFIED ALTERNATIVE LOCKSET/DEADBOLT HARDWARE IS GRADE 2 BY PAMEX AND DELANY. 14. MAX. PANEL WIDTHS APPLY TO ALL CONFIGURATIONS, MULLED OR NON -MULLED UNITS. TYPE MAX. PANEL SIZE DESIGN PRESSURE RATING IMPACT RATING SINGLE 37-5/8" x 95-3/16" +/- 70 PSF LARGE MISSILE IMPACT FRENCH SIDELITE 33-5/8" x 94-5/8" LucasTurner 2017-09-22 13:18-04:00 8700/10/50 PVC SWING DOOR IMPACT z 3 a 2 3 Z WJO aFWOW w ZOz m==F 0 Zw§a0M3d` O QW LLF_ma O Z�] ZI-ON OzpviZOO- I"-LLEOOLLO K 30D'Ft z w oo�is3o`F W D NOWw p0 w 0 Ilml, m M ax�y a � a K3a No 58201 STATE OF z� LUCAS A.TURNER, P.E. FL PE # 58201 1239JABARAAVE. NORTH PORT, FL 34288 PH. 941-380-1574 GENERAL NOTES AND ELEVATIONS AWN BY: DATE: ADE 09/08/11 l04 REV.: CWS-641 c ALE' SHEET 1:35 1 OF 12 151 3fe' MAX V(S(lnylLom p / WINDOW SYSTEMS �i� 1900 SW 44TH AVE. OCALA. FLORIDA 34474 WWW.CWS.Cc 8700/10/50 PVC SWING DOOR IMPACT 1` a z 3 <zo <UN ? woo HT o zoz W--� Z �: V ii UL"FtiIF�i. ' N Z U LL Z 6 j z F D N IL I OZUNZO— F LL W 0 0 0 3 Z wo�i�3o� N00D,NW a �KON GLASS DLO O W f 0 M S p N n € a FRENCH DOOR W/SIDELITES p�`OAOREW ��#q 1153116'MAX UNIT WIDTH 763/16' MAX. UNIT WIDTH No 58201 363116' MAX SIDELITE WIDTH 40' MAX SINGLE DOORWIDTH '9: STATE OF .41� 335/B'MAX 37 MAX. F 2 TH PANEL WIDTH DOOR WIDTH DOOR �4i S,ONA';EN�p 9T MAX. UNIT HEIGHT 9/22/2017 94 94 �,161W26X5/8' 95 3/16' LUCAS A TURNER, P.E. 16' SIDELITEPANEL HEIGH7 L HEIGHT 1239 JA6ARA AVE. H7B3IB'3/16'NOPHH941-380F1574IL 288 SIDELITEDOORSnEETDESCwPTlON: GLASSGLASSDLO DLO GENERAL NOTES AND ELEVATIONS DRAWN BY: DATE ADE 09/08/11 GLASS DLO GLASS DLO GLASS DLO GLASS DLO DWG#: HE'. SINGLE DOOR W/SIDELTE CWS-641 C FRENCH DOOR W/SIDLITE B—E SHEET 1:35 2 OF 12 3631i6' MAX 9T UNIT WIDTH 7g• -SIDELITE WIDTH — - MAX FRENCH DOOR WIDTH 33518• 375/B' MAX PANEL WIDTH PANEL WIDTH MAX UNIT HEIGHT SIDELITE Q X X O PANE HEIGHT 9T 383H6' MAX 79° SIDFIITE WIDTH MAX FRENCH DOOR WIDTH 336/8' MAX 37518' MAX PANEL WIDTH DOOR W ID MAX UNIT HEIGHT SIDE ITE Q X �( 953/ HEIGHT PANE 03518' FLOSH 40' MAX SINGLE DOORWIDTH 3758' MAX PANEL WIDTH 26 SIB' GLASS DLO .I T NOTE:HINGE SPACINGS 81'Ffl[ FROM MAX nFLUSH EARE NDSANY 1fi' ENDS AND 2IS/16UNITMAX O.C. UP TO HEIGHT81' UNIT HEIGHT. 4 81/2' SINGLE DOOR 79' MAX. FRENCH DOOR WIDTH 36 3/16' MAX - -- SIDELITE WIDTH 37518' MAX 335/8' MAX - PANELWIDTH PANELWIDTH 265/8' 225/9' - GLASS DLO GLASS DLO � NIT BOLT EIGHT 79 3/16' PANEL x p o x HEIGHT 683116' SEE GLASS DLO NOTE4 T1 15130 MAXUNITWIDTH 363/16'MAX 79' MAX FRENCH DOOR WIDTH SIDELITE WIDTH 335/8' MAX 37518' MAX PANELWIDTH PANELWIDTH T FLUSH AAX BOLT JNR 4EIGHT 7931 785/B' DOD SIDELITEO X X O HEIGHT HEIC 67 5/8' 683116DOOR E GLASS GLASS LASS SEE GLASS DLO NOTE DLO SHT1 22 Sfi' 26 5/8' FRENCH DOOR W/SIDELITES IB' i °L HT FRENCH DOOR 78 le- SIDELITE 112 3/8' MAX UNIT WIDTH 363116' MAX 40' MAX SIDELITE W IDTH DOOR W IC 335/8' MAX 375/8' MAXMAX PANELWIDTH PANEL WIDTH i� �' -FLUSH INIT BOLT 1EGGHT IG DOO DOO 785/9' PAN( SIDELITEF O ax O HEIC HEIGHT 88 3/18' SIDELITE DOOR GLASS GLASS DLO DLO i 225/8' 265V SINGLE DOOR W/SIDELITES 1900 SW 44TH AVE. OCALA. FLOPJDA 34474 W W W.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT a _z 3 <z3 W yw0 Qr❑ EW k1 0 zvOlz Of LL U la-mx3ZrI-33�; U~OZ ❑ z �WC`p zy-m-z o_m G ON-moz LL _ H � FQ�❑N�OU~Ztll ID �❑w 0wvlW a O Z2 W020 WHO W=62 a a D:3w Ne 58201 rH o[ ili STATE OF LE 2 xZ L HT 9/220017 LUCAS A. TURNER, P.E. FL PE # 56201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SHEET DE MnIDN: GENERALNOTESAND ELEVATIONS DRAWNB: DATE: ADE 09/08111 DWGa. REV.: . CWS-641 C Ste` SHEET 1:35 3 OF 12 9' OVERALL 3116' TEMPERED 5/16' AIRSPACE V2' LAMINATED 3116' ANNEALED 105 DUPONT PVB INTERLAYER 3116' ANNEALED SIKA- SIKAFLEX 552 or �HENKEL- PURFECT GLAZE'H' 3/4' GLASS TYPE A OUANEX DL IG SPACER GLASS TYPE B GLASS TYPES MAX. UNIT NgGNT S10ELITE SINGLE FRENCH 81' A A A 9r B B B 1' OVERALL 3116'TEMPERED 3/8' AIRSPACE 7116' LAMINATED 3116' ANNEALED &E SENTRY GLASS IONOPLAST INTERLAYER 3116" ANNEALED SIKA-SIKAFLEX 552 or HENKEL - PURFECT GLAZE'H' 3/4' GLASS SITE 1900 SW 44TH AVE. OCALA. FLORIDA 34474 www.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT a i 3 az3 O wwwFO W ZOz KFzf o aNi Yoa;,,,_ z o�o'd�W�`. i U UN F-ZafIF/1'1 O 2-� ZHJy O_ZUviZJO- Y-Owr=09 4$3ow w I xwnwI/11��1 S �Sd KON O w 0 O.S,y No SB201 STATE OF zz LUCAS A TURNER, P.E. FL PE k 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 IEET DESCRIPTION: GLAZING DETAILS AWNS: DATE AIDE 09/08/11 VG REV.: CWS-641 c ue SHEET 1:1 4 OF 12 INTERIOR WINDOW SYSTEMS ICJ 68 7 4 3S 4 46 81 68 7 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 64 3 8700/10/50 PVC SWING DOOR s3 IMPACT 9 3 3 < 3 0Z0 w o <kzw O 19 s 64 _ w 0 zo3 W__t am3i-3:2 1 1 u z 0 z Hw r;� ZS0< w0, �d U oro Zd�y�. U Z OOVNZJON <3owoioz 4 8 56 5841 0 3 1 4 IS 44 6 < - o�K�YjiO� LLv1tSNOWCh rgf z'O O�VN Wf0 � W2, r a a 0:ia SECTION VIEW B43 r N. 55201 'FA fi0 38 p91 - �9t. STATE OF :41I 7• •'OAF` :4 3 y�•'S;�oNn�E�:�`�`, ALTERNATE ALTERNATE 1FRE 4 �9/22I2017 "MORTISE LUCAS A TURNER, P.E. H BOLT 3 MULTIPOINT LOCK FL 9 1239 JA ARAA 0 59 PORT, FL 342 NORTH PORT, -1 74288 PH. 941380-t574 14 5 SHEETDESCIWTION: 69 SECTION VIEWS 6 SINGLE DOOR 6 ITEMS NOT SHOWN FOR CLARITY: DRAWN er: MTE: 56 3 5051 10-12. 13. 15-17. 22, 43, 48, 54.57-58 ADE 09108/11 SECTION VIEW A -A ITEMS NOT USED IN VERSION SHOWN: 23, 8-9, 15-16, 25-28, 3034, 36-40, 43, 5253, 60, 62.654i6, 72, 76 Dwou. CWS-641 Rom" C sc>�: SHEET 12 5OF 12 WINDOW SYSTEMS 1900 SW 44TH AVE. OCALA FLORIDA 3U74 W W W.CWS.CC INTERIOR 8700110/50 PVC SWING DOOR 7 81 3 33 3 3 6 1 66 14 14 39 3 fit fib 7 IMPACT a z aZ3, OWO NWpp zOz YOKE~ a 3 3 z zOXh E,d�W��l i p, OU w x�_ KMC 0 LL W 0 Z L.,�.J w � 1 Z 00 �WE W N Dwww � a O ?ND. KONm W�O M2y Of a wx Al, 19 3 4 4 1 3 4 30 31 3 68 D 13 3 4 2 3 1 4 1 18 19 3 4 44 fi .```,,,P;.�O E�EW ,r. •y\ . Ci N•.Z: SECTION VIEW C-C �9'. BTATE OF :1uL OAR..( '�SS�ONALEY.o`. ��4OITp101` zz 9/22I2017 LUCAS A. TURNER, P.E. FL PE It 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 SHEET DESCRIPTION: SECTION VIEWS FRENCH DOOR NOTE: VERTICAL SECTION SIMILAR ITEMS NOT SHOWN FOR CLARITY: DRAWN BY. DATE TO SINGLE DOOR, SEE SHEET 5 10.13. 15-17, 22, 26-28, 36-39, 43, 54, 57 ADE 09/08/11 Uwe REV.: ITEMS NOT USED IN VERSION SHOWN: CWS-641 C 8-9. 15-16, 25, 40. 42. 4546.48. 5253, 56. 60, 74, 76 cA�E s SHEET 1:2.5 6OF 12 WIN W SYSTE� 6 INTERIOR 53 9 1900 SW 44TH AVE. OCALA, FLORIDA 34474 WWW.CWS.CC 8700/10150 PVC DOOR 9 IMPACT 40 ��SWING < Z 3 Qz0 O NFWFO 19 5 6 ZOZ 4 o KF2IF 'M'H3- 6 O 40 19 4 4 4 3 4 0 z Q OOUpj—jON FzLL `C OOLLZ SECTION VIEW E-E ¢30 �F rz- 00 53:92 LLNRW'NO WNW 1 �_LL KONN —SEALANT APPLIETO p W�O LL=Km 3 6 8 1 ADJOININGINING FACES BY INSTALLER _ �gDREW� pP�pHpREW INTERIOR '��:' No 58201 :FA% #10 HEX WASHER HEAD TEK •A'% #. =_•G JOINING DOOR FRAME TO SIDEUfE. =b[ 6•FROM TOP AND BOTTOM �91. STATE OF .W 17• MAX. O.C. A, P .. 2T4. T�::S�ONAEC,��p zx 0 9/22I2017 5 5 LUCAS A. TURNER, P.E. g SEALANT APPLIED TO #10-24 z 1-3/4• TYPE F FL PE # 58201 ADJOINING FACES THRU HINGE INTO SIDELNE AT EACH HINGE. 1239 JABARA AVE BYINSTALLER SEE SHEETS 183 FOR HINGE SPACING. NORTH PORT, FL 34288 PH. 941-380-1574 SHEETOESCR"10W SECTION VIEWS 9 ATTACHED SIDELITE ITEMS NOT SHOWN FOR CLARITY: DRAWN9: GATE: SECTION VIEW D-D 10-11. 16, 22, 28, 43. 57 ADE 09/08/11 ITEMS NOT USED IN VERSION SHOWN: OWDu: Rev.. 1-3, 6-15, 17-18, 20-21, 23-24, 26-27, 30-39, 41, 44-46, 48-52, 54-56, 58-61, 63-71, 74-76 CWS-641 C S�E' SHEET 12 7OF 12 PARTS LIST PARTS LIST REM PART# DESCRIPTION MATERIAL VENDOR ITEM PART# DESCRIPTION MATERIAL VENDOR //y (/ nnrc9fSimTy�.l //// 1 1141833 MAIN FRAME HEAD ALUM KEYMARK 51 PS131 GASKET DOORSILL BACK FOAM MO PRODUCE 2 141857 ASTRAGAL, INACTIVE, FD PVC ALUM KEYMARK 52 P-5134 SCREW,#10 X1-34- FLAT SQUARE TYPEF HINGE FASTENAL WINDOW SYST(815 I`DL�-�j 3 14-18S8 ASTRAGAL ACTIVE FD, PVC ALUM KEYMARK 53 P-5151 GASKET, SIDELITE FOAM I HO PRODUCTS 1900 SW 44TH AVE. 4 Fi-1880 REINFORCE1vE1-!� VERT. ALUM KEYMARK 54 P-6157 SCREW #10-24 x 1/2'. FI Un&emul PH, 18-BSS @ KEEPER FASTENAL OCALA FLORIDA 34474 WWW.CWB.CC 5 141861 REINFORCEMENT, HORIZ ALUM KEYMARK 55 P-5158 BOTTOM SEAL RUBBER TEAM - 6 91878 MAIN SILL ALUM KEYMARK 56 P-5172 WSTP,.370 X.187, TRI FN. BLACK ULTRAFAB 8700/10/50PVC SWING DOOR IMPACT 7 K1880 MAINFRAME. JAMB ALUM KEYMARK 57 P-5174 SCREW #8X3/4-HEXWASHER HEAD, @FRAME FASTERAL 8 K1881 MAINF SIDELITE 0, DOOR ALUM KEYMARK 58 PS786 SCREW #8-32 x 7-1/4' PH,FLMS, SS @PLUNGER SS FASTEMAL 9 H-1900 MAINFRAME SIDELITE JAM® HEAD SILL ALUM4 KEYMARK 59 S-1783 THRESHOLD, HIGH RISE ALUM KEYMARK 10 1 P-3039 ISETITINGBLOC 85DUR118X1X2 RUBBER FRAMQOWE 60 S-1784 INSERT. REINFORCEMENT ALUM KEYMARK 11 SIKAFLEX 552 of PLWECTGLA7E'F{ SIKA- 61 S-18M COVER JAMB, ANCHOR ALUM KEYMARK 12 R3503 SCREW #8 X 1/2' PH TRIES SS ASTRAGAL CAP FASTENAL 62 S-1816 COVER JAMBS, HEAD,SILL, SIDELITE ALUM KEYMARK z w 12 o o Y ¢ ru < z O w.wi o <w O w zOz rck?t G N 3 O K 3 / O r o a X w C, Z m y i z a O z V ui z O Q y H IO N—F o= W Z y - g m. 00 ri o w y w 13 P-3511 SCREW #8 PAN TEK TIEROD FASTENAL 83 S-1817 DRIP CAP ALUM KEYMARK 14 P-3587 X 1', HI SCREW #BX 1' PH FLATTEK ASTRAGAL INSERT LOCI( L, IN FASTENAL 64 5-1840 COVER HEAD, ANCHOR ALUM KEYMARK 65 5-1849 INSERT, INACTIVE PNL. LOCK HARDWARE KEYMARK SCREW, DELITEFASTE_ SISIDELRE 67 59 COVER, ASTRAGAL, FD ALUM YMARK 18 Pd146 SCREW #8 X 314 P FIAT SS lEK 51-0M FASTENAL S-78854 INSERT, FRONT, STM ATTACH SILL ALUM KEYMARK 77 P-0278 FIFTY PAD .200' x 1.250' WIADHESIVE ULTI24FAB fib S-1865 INSERT, BACK, BTM ATTACH SILL ALUM KEYMARK 18 P4522 #10 x 1 114' PH FLAT SMS-HINGE PANEL FASTENAL 69 5-1915 BASE, SWEEP ALUM KEYMARK 19 P-4774 WSTP BUI-B/LEAFS PALL AMESBU Y 70 5-1916 DRIP COVER SWEEP ALUM KEYMARK 20 P-4790 FLUSH BOLT ASSM TOP/BTM SULLIVAN 71 S-BM PANEL TOP/BTM RAIL. SIDES -DOOR PVC MIKRON 21 P4794 SCREW #8 x5/8' SOFLAT TEK A INSERTATTACH FASTENAL 72 5 83 PANEL, TOP/BTM RAIL, SIDES -SIDELUE 22 P4802 ALL TI67FADED ROD (TIE ROD MDMASTER 73 S4i084 GlA21NG BEAD (1') rc z y O -i m t- 23 P-4807 HINGE GUIDE HOPPE 74 N41888 REINFORCEMENT, VERT., SNGLE DOOR O w O a i m 24 P<eoamaew HINGE Sf-T HOPPE 75 GLASS SEE SHEET4 =ALUMKEYMARK m u �3w 25 P-4814 WSTP .50X750 FOLDED BULB SEAL SIDELITE AMESBURY 76 H-IMZ REINFORCEMENT VERT. 26 P4883 LOCK STRIKE PLATE PADDOCK 77 P4887 MORTISE LOCK 27 P-4864 RI-0NO STRIKE PLATE PADDOCK I HEAD SILL ALL FRAMES ARE MECHANICALLY FASTENED 'ALTERNATE APPROVED LOCKSETS: PAMEX GRADE 2 LOCKSET AND DEADBOLT ,p"TO�REW�Tp Q`i I y1G ENy"t,•G,D!. ' No 58201 ''4As *? Z9P% STATE OF 144/ •� T :�( OP••�2 �:6�3 •. ,QR1,..•'O. 'oy /ONA11EN``�� - - X� 91=017 28 P-4866 GUIDE TIE ROD NYLON M&M 29 P4871 TIE ROD BRACKET ZINC SULLIVAN�� 30 P4885 SHOOT BOLT TOP PADDOCK 31 P4886 SHOOT BOLT BOTTOM PADDOCK 32 P4851 LOCKS INACTIVE 8 FT 32 P4884 LOCKBAR, MULTI -POINT 5PT 8FT PADDOCK 32 P4901 LOCKBAR MULTI -POINT, 4PT US FT PADDOCK 32 P4902 LOCKBAR, INACTI 6-8 FT PADDOCK 33 P4903 HANDLE SET ACTIVE PADDOCK 34 P4905 HANDLE SET, INACTIVE PADDOCK 35 P4913 WSTP .50XS0 FOLDED BULB SEAL DOOR SCHELGEL 36 P4917 CAP ASTRAGAL,OUTSIDE NYLON M&M 37 P4918 GUIDE, FLUSH BOLT INACTIVE PNL M&M 38 P4922 COVER INTERIOR FLUSH BOLT NYLON M&M LUCAS A TURNER, P.E. FL PE # 58201 1239JABARAAVE. NORTH PORT, FL 34288 PH. 941-380-1574 39 P4925 CAP ASTM INSIDE NYLON M&M 40 P4926 SHIM SIDEURE DOOR SHIPPING BLOCK NYLON M&M 41 P4927 GUIDE, FLUSH BOLT NYLON M&M 42 P4930 SCREW 910 X 1-1WHEX HEAD TEK SIDELITE ATTACH FASTENAL 43 P4933 NUT 3/8-46 FLANGED W/SERRATED UP SS, PANEL MCMASTER SHEETDEScaw10W BOM 44 P4934 SCREW, 012-24X 1/2'PH FLAT MS HINGE FASTENAL 45 P4936 DOORKNOB ACTIVE PANEL DELANY 46 P4937 DEADBOLT ACTIVE PANEL DELANY 47 P4969 SCREW 010 X 2' REI✓F. ATTACH. FASTENAL DMWN BY: ADE DATE: 09/08/11 48 P4997 STRIKE DEADBOLT PADDOCK 49 P-5127 SCREW #12X7 PH PAN SMS ANCHOR FASTENAL DWG x: CWS-641 BEv.: C 50 P-5130 GASKET DOOR SILL,FRONT I )AM I HO PRODUCTS s 1:1 SHEET 8 OF 12 i49H6'� 7/78' DOOR HEAD-1833 49H6'�{ „L ❑ �I 6 7116' DOOR SILL-1878 I�49/16'------ I �IIj7� V2V1,16. 7 2 DOORJAMB-1880 SIDELITE-1881 d4 9/ifi°� 9 2 1/18• LO ,/76• SIDELITE-1900 NOTE: ALL EXTRUSIONS ARE 6063-T6 ALUMINUM PVC DOOR PANEL -6083 REINFORCEMENT -1861 r 1 1/2' TI116- 2,5/7fi' REINFORCEMENT-1880 L 66 2I, i/76' L ASTRAGALCOVER-1859 4 2 REINFORCEMENT -1857 REINFORCEMENT -1858 REINFORCEMENT -1862 1 3/4•l I 6 L INSERT. INACTNE PNL-1849 27/16'�j ( SIB. WINDOW SYBTEN9 yll 59 -�{.--(�) 1900SW44THAVE. 1 ma's• 1116' 9ry6 • �' A OCALA FLORIDA34974 WWW.CWS.CCS.CC THRESHOLD-17B3 HEAD COVER -1840 8700/10/50 PVC s/e• SWING DOOR z 1/4• IMPACT 1/4'�1—61 38T- 60 a Z aZ3 FILLER -1784 1 Ow0 wwOp i Wpm < Ow FRAME COVER -1806 w FyZ)mOm?t- 5/8' �23/8'� OFO ZSwSD U UtnyZdFNu T- 71/116' 3 < OZ VvizDVN SIDELITE COVER-1816 PVC GLAZJNG BEAD -6084 ooK�¢y j i pm w B Nowow olwt; mo- �N6 O wry mm�h -4118 '---'r L_ a s rc 3 a a175/16' 58. 63 �P"PNOREW l_ 69 DRIP CAP -1817 fS:- No 58201 BASE SWEEP -1915 %,P-. STATE OF .•414 314' �---y � '4FS�.. O.. 10s''p�2�.`` 88 0 316 ,M6' 73l16• 1/16• 1 ZZ INSERT, BACK -1865 GRIP COVER -1916 LUCAS A. TURNER, P.E. FL PE It 58201 1239 JABARA AVE. NORTH PORT, FL 34288 9/16'- -" PH. 941-380-1574 I I 6 SMEtT �ESCHIP110N: 77116 J_ 1/7fi' EXTRUSIONS INSERT, FRONT-1864 DMW BY: GATE: ADE 09/08/11 MG A.. REV.: CWS-641 C 8-E SHEET 1:2 9 OF 12 ANCHOR Q MIDSPAN (TY'P.) 4' (TYP.) 6' MAX (TYP.)� 6'MAX (TYPJ_L I-� I �'"4• (TYP.) A -1. r no I-r i I ix MAX.C. ) 22' (TYP.)-WOOD/METAL • II 11--'SEE NOTE ANCHOR @ MIDSPAN (TYP.) 6' MAX. (TYP. S' MAX (TYP. O I ANCHOR (TYP.) D.C.17' MAX INSTALLATION RY L 4' (TYP.) SIDELITE DOOR SIDELITE SIDEUTE DOOR DOOR SIDEUTE ANCHOR LAYOUT- (FLANGE) ANCHOR LAYOUT - (FLANGE) IN WOOD AND METAL INSTALLATIONS. DO NOT INSTALL THESE ANCHORS INTO MASONRY. NOTES: 1. INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION. SILL ANCHOR SPACING SAME AS HEAD. )DIMETAL SEE NOTE 2 ^INSTALLATION ANCHOR (TYP.) 2. SHIM AS REOAT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX ALLOWABLE SHIM STACK TO BE 114'. USE SHIMS WHERE SPACE GREATER THAN 111V IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 3. ANCHOR TYPE, SIZE, SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS, SEE TABLE 1, SHEET 11. 4. ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST BE PROTECTED TO PREVENT REACTION. S. INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM SPECIFIED IN TABLE 1, SHEET 11. 6. ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE)CMU OPENINGS, EMBEDMENT SHALL BE BEYOND WOOD BUCKS, IF USED, INTO SUBSTRATE. INSTALLATIONS TO SOLID CONCRETE OR GROUT -FILLED CMU MAY INCLUDE BUT DO NOT REQUIRE I WOOD BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. INSTALLATIONS TO HOLLOW CMU REQUIRE THE USE OF 1X BUCKS BETWEEN THE PRODUCT AND SUBSTRATE. 7. A MINIMUM CENTER -TO -CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS: 4' FOR MASONRY, 2-3/16' FOR HINGES (ALL SUBSTRATES), 1' FOR WOOD AND METAL. 6. WOOD OR MASONRY OPENINGS, BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET, SHEET 11. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. 9. SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: FMA/AAMA 100(FIN WINDOWS), FMA/AAMA 200(FLANGE WINDOWS), FMAAYDMA 250(BOX W INDOWS), FMAJAAMANVDMA 3D0(EXTERIOR DOORS) WINDOW SYSTEMS D 1800 SW 44TH AVE. OCALA. FLORIDA M474 W W W.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT zz LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 ANCHOR SCHEDULE AND NOTES ADE 09/08/11 IG 9 REV_ CWS-641 C Ate' SHEET 1:8 100F 12 TYPICAL HEAD ANCHORAGE I it PERIMETER SEALANT— d- �¶ BYINSTALLER INSIDE AND OUT CONTINOUS DBL 1W BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND SUBSTRATE BY INSTALLER. PERIMETER SEAT BYINSTALLER INSIDE AND OUT SUBSTRATE BY SEE TABLE 1 (n 1 VERTICAL SECTION 11 TYPICAL SILLANCHOWIE MIN. EDGE DIST. INTERIOR SEE TABLE 1 CONTINOUS DBL 1/4' BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED N.EMBEDMENT POINTS BETWEEN FRAME AND SUBSTRATE E TABLE 1 BY INSTALLER. INSTALLATION ANCHOR — SEE TABLE 1 `1/4' MAX. SHIM INTERIOR INSTALLATION ANCHOR SEE TABLE i MIN. EMBEDI SEE TABLE 1 MIN. EDGE DIST. SEE TABLE 1 TABLE 1: APPROVED INSTALLATION FASTENERS SUBSTRATETYPE ANCHORTYPE MIN. EMBEDMENT MIN. EDGE DIST. CONCRETE (2.85 KSI MIN.) 1/4' ELCO ULTRACON i i/4- 2-1/2' HOLLOW OR GROUT -FILLED CMU (ASTM C-90) 1/4- ELCO ULTRACON 1-1/4' 2-1/2' ZX MIN. SOUTHERN PINE (G=0.56) 1/4' ELCO ULTRACON 1-Tal 718' ZX MIN. SOUTHERN PINE (G=0.55) #12 WOOD SCREW 1-W8' 7/B' 16 GAUGE (0.060') MIN. #12-14 HLTI KW IK-FLEXOR ITW FULL THREAD STEEL STUD (33 KSI YIELD MIN) TEKS SELF-DRILUNG SCREW THRU 0.060' 1/2' 1/8' ALUM. (6D63-T5 MIN.) OR #12 GRADE 5 SELF -TAPPING ) FULLTHREAD 1/8' STEEL (33 KSI MIN.) DRILLING SCREW THRU 0.12Y 1/2, HINGE ANCHORS INTO CONCRETE (2.85 KSI MIN.) 3116' ELCO ULTRACON 1-3/4' 2-1/Tl HINGE ANCHORS INTO HOLLOW OR GROUT -FILLED y16' ELCO ULTRACON 1-114' 2-1/2" CMU ASTM C-90) HINGE ANCHORS INTO 2 MIN. SOUTHERN #10WOODSCREW 1.1/8' 7/8' PINE G=0.55 HINGE ANCHORS INTO 16 GAUGE (0.060') MIN. 010.16 HLTI KWIK-FLEX OR IIW FULL THREAD STEEL STUD (33 KSI YIELD MIN) TEKS SELF -DRILLING SCREW THRU 0.060' LIT HINGE ANCHORS 1/8' ALUM. (W0 T5 MIN.) OR #10 GRADE 5 SELF -TAPPING / FULLTHREAD 1/8' STEEL (33 KSI MIN.) DRILLING SCREW THRU 0.125' 1/2' 1/4' MAX. SHIM MIN. EMBEDMENT SEE TABLE 1 / --T MIN. EDGE DIST SEE TABLE 1 SEE TABLE 1 PERIMETER SEALANT BY INSTALLER HINGE MIN. EMBEDMENT INSIDE AND OUT SEE TABLE 1 SUBSTRATE BY OTHERS SEE TABLE 7 B HORIZONTAL SECTION 11 TYPICAL JAMB/HINGE ANCHORAGE 1900 SW 44TH AVE. OCALA FLORIDA 34474 W W W.CWS.CC 8700/10/50 PVC SWING DOOR IMPACT No 58201 213116- 81/2' (TYP.) %1%% STATE OF ANCHORSTHRU� HINGE (TYPJ z� 21511V MAX 9/22/2017 SEE NOTE LUCAS A. TURNER, P,E. FL PE # 58201 1239 JABARA AVE. NOTE: NORTH PORT, FL 34288 HINGE SPACINGS ARE: PH. 941-380-1574 8-1/2' FROM ENDS 21-5/16' MAX O.C. FOR UP TO 81' UNIT HEIGHT. SHEETUESCRIPTIDN: 20' MAX O.C. FOR OVER 81' UNIT HEIGHT. INSTALLATION DETAILS DOOR DRAWN BY: DATE, AIDE 09/08/11 MG P. REV.: HINGE LAYOUT CWS-641 C 1:30 Scale SHEET 12 1 1OF 12 TYPICAL HEAD ANCHORAGE SUBSTRATEF SEE TABLE 1, INSIDE AND OUT �� CONTINOUS DBL 1/4' BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND SUBSTRATE BY INSTALLER. SUBSTRATE BY OTHERS SEE TABLE 1, BHT 11 ( �. , VERTICAL SECTION 12 TYPICAL SILLANCHORAGE INTERIOR 11 CONTINOUS DBL 1/4' BEADS OF SEALANT AROUND PERIMETER AT ALL INDICATED POINTS BETWEEN FRAME AND SUBSTRATE BY INSTALLER. 11 1/4' MAX. SHIM INTERIOR INSTALLATION ANCHO SEE TABLE 1, BHT 11 MIN. EMBEDMENT SEE TABLE 1, BHT 11 MIN. EDGE DIST. SEE TABLE 1, BHT 11 PERIMETER SEALANT BY INSIDE AND OUT SUBSTRATE BY OTHERS SEE TABLE 1, BHT 11 IW MAX. SHIM - - cULlN1(4UUU[/(j L/e(/Q MIN. EMBEDMENT WINDOW SYSTEMS Ip1,(jlZ SEE TABLE 1. SHT 11 1800 SW 44TH AVE. L4, FLORIDAFL WWW'C.cC3M74 W W SEE TAB EDIS MIN. EDGE HT 11 8700/10/50 PVC SWING DOOR IMPACT a 3 3 azo oa <W❑W w WJo ZOz K=�)- o aw3-13; U U o �N5 ❑ N Z Z-N Z'nl z Oz1oz, moz 01 00�fY/10WN� K zZ Sy KONh HORIZONTAL SECTION r~ a rc 3 N 12 TYPICALJAMB ANCHORAGE No 58201 STATE OF 91=017 LUCAS A. TURNER, P.E. FL PE # 58201 1239 JABARA AVE. NORTH PORT, FL 34288 PH. 941-380-1574 HE DEsMr *N: INSTALLATION DETAILS SIDELITE MWNB: MT: ADE 09/08/11 WGN: REV.: CWS-641 C SHEET 1:2 12JF 12 FICE USE ONLY: DATE FILED: % Z REVISION FEE: 00 PERMIT# %9DI —006C — RECEIPT # l,S SCANNED PLANNING & DEVELOPMENT SERVICES BY BUILDING & CODE REGULATION DIVISION St. Lucie County 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 RECEIVED (772) 462.1553 FEB' A 7 11118 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION permitting oepart omen Coty LOCATION/SITE ADDRESS: / 12,Jc—rz&r—nL AA %e %? ZzArw c3 - DETAILED DESCRIPTION OF PROJECT REVISIONS: cG n e,&7,j �. i iu uG ��Aiia i v Sunl �mn.o VO4E 9or��YaLc CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE CO BUSINESS NAME: — (LMgiy�%doe �/10 QUALIFIERS NAME ZJ ADDRESS: CITY: A./ &Xz,0,e STATE: 71 PHONE (DAYTIME): 76— 15'$7 - 97 ot FAX: CITY: re) n j Sj - PHONE (DAYTIME): SLCCC: 9123109 Revised 06130117 INFORMATION: STATE: FAX: ZIP: ZIP: REV(§ION Qrnlw 1,14, lgrl -ZY7S� s RECEIVED FFg 2 4 1010 FORM R405-2017 Permfttlgg Oe FLORIDA ENERGY EFFI8'I _A CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: NOEL RESIDENCE Builder Name: RAPHAEL HENRI Street: 12103 RIVERBEND ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE , FL, Permit Number: Owner. Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (4799.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 4439.00 it- b. Frame -Wood, Adjacent R=13.0 360.00 ft- 3. Number of units, if multiple family 1 c. NIA R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 10. Ceiling Types (5295.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=30.0 5295.00 ft= 6. Conditioned Floor area above grade (ft') 5294 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(1078.0 sqft.) Description Area a. Sup: Aftic, Ret: Aftic, AH: AHU 1 6 200 a. U-Factor. Sgl, U=0.65 504.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 125 SHGC: SHGC=0.21 c. Sup: Attic, Ret: Attic, AH: Attic 6 125 b. U-Factor. Sgl, U=0.58 486.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.24 a. Central Unit 46.5 SEER:16.00 b. Central Unit 17.9 SEER:16.00 c. U-Factor. Sgl, U=0.33 88.00 ft. 2 additional cooling systems (see details) SHGC: SHGC=0.16 13. Heating systems kBlu/hr Efficiency d. U-Factor. N/A ft' a. Electric Strip Heat 34.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 4.699 ft. 2 additional heating systems (see details) Area Weighted Average SHGC: 0.219 14. Hot water systems a. Electric Cap: 40gallon 8. Floor Types (5294.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 5294.00 ft' b. Conservation features b. N/A R= ft. None c. N/A R= ft. 15. Credits None Glass/Floor Area: 0.204 Total Proposed Modified Loads: 147.72 PASS Total Baseline Loads: 159.58 1 hereby certify that the plans and specifications covered by Review of the plans and iliE SpalR this calculation are in compliance with the Florida Energy specifications covered by this �F y Code. calculation indicates compliance y ,, z v ith the Florida Energy Code. F rnr„ ••, _ ?y;M� „ O PREP D Before construction is completed a a DATE: - this building will be inspected for compliance with Section 553.908 ilV; O I hereby certify that this ildj g, as designed, compliance Florida Statutes. COO 4¢� with the Florida Energy WE OWNER/AGENT' BUILDING OFFICIAL: DATE: v DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 2/17/2020 8:37 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 CORM R405-201'7 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: NOEL RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 5294 Lot # Owner Name: Total Stories: 1 Block/Subdivision: #of Units:' 1 Worst Case: No PlatBook: Builder Name: RAPHAELHENRI Rotate Angle: 0 Street: 12103 RIVERBEND RO Permit Office: ST LUCIE COUNTY Cross Ventilation: County. St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: City, State, Zip: PORT ST LUCIE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number' Name Area Volume 1 Blockl 2914 29140 2 BloclQ 908 9080 3 Block3 924 9240 4 Block4 548 7124 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 AHU 1 2914 29140 Yes 0 2 1 Yes Yes Yes 2 AHU 2 908 9080 No 0 0 1 Yes Yes Yes 3 AHU 3 924 9240 No 0 1 1 Yes Yes Yes 4 MINI SPLIT 548 7124 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation AHU 1 159 ft 0 2914 W _ 1 0 0 2Slab-On-Grade Edge Insulation AHU 2 70 R 0 908 ft' — 1 0 0 3SIa1b-On-Grade Edge Insulation AHU 3 122 ft 0 924 fl' — 1 0 0 4'SlabOnrGrade Edge Insulation MINI SPLIT 521t 0 I 548 ft' -- 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 I I Hip Barrel tile 5921 ft' 0 ft' Medium N 0.6 No 0.9 No 30 26.6 ATTIC / V IRCC # Type Ventilation Vent Ratio (1 in) Area RBS 1 Full attic Unvented 0 5294 ft' N N 2/17/2020 8:37 AM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Ed,'dlon (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) AHU 1 0 Blown 2914 ft- 0.11 Wood _ 2 Under Attic(Unvented) AHU2 0 Blown 908 ft' 0.11 Wood _ 3 Under Attic (Unvented) AHU 3 0 Blown 925 ft' 0.11 Wood 4 Under Attic(Unvented) MINI SPLIT 0 Blown 548 ft' 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below A! C)r�t TO Wnli Type Space _ 1 E Exterior Concrete Block- Ext Insul AHU 1 4.09999 34 10 340.0 IF 0 0 0.600000 0 _ 2 S Exterior Concrete Block- Ext Insul AHU 1 4.09999 42 10 420.0 ft 0 0 0.600000 0 _ 3 W Exterior Concrete Block- Ext Insul AHU 1 4.09999 65 10 650.0 ft' 0 0 0.600000 0 _ 4 N Exterior Concrete Block- Ext Insul AHU 1 4.09999 28 10 280.0 ft' 0 0 0.600000 0 _ 5 E Exterior Concrete Block- Ext Insul AHU 2 4.09999 30 10 300.0 ft' 0 0 0.600000 0 _ 6 W Exterior Concrete Block- Ext Insul AHU 2 4.09999 22 10 220.0 ft- 0 0 0.600000 0 _ 7 N Exterior Concrete Block- Ext Insul AHU 2 4.09999 32 10 320.0 ft' 0 0 0.600000 0 _ 8 E Exterior Concrete Block- Ext Insul AHU 3 4.09999 27 10 270.0 ft' 0 0 0.600000 0 _ 9 S Exterior Concrete Block- Ext Insul AHU 3 4.09999 47 10 470.0 IF 0 0 0.600000 0 _ 10 W Exterior Concrete Block- Ext Insul AHU 3 4.09999 31 10 310.0 ft' 0 0 0.600000 0 _ 11 N Exterior Concrete Block- Ext Insul AHU 3 4.09999 17 10 170.0 ft' 0 0 0.60000D 0 12 E Garage Frame -Wood AHU1 13 28 10 280.0 ft- 0 0.25 0.600000 0 13 N Garage Frame -Wood AHU1 13 8 10 80.0 ft' 0 0.25 0.600000 0 14 W Exterior Concrete Block- Ext InsuMINI SPLIT 4.09999 42 13 546.0 ft2 0 0 0.600000 0 15 S Exterior Concrete Block- Ext InsuMINI SPLIT 4.09999 11 13 143.0 ft' 0 0 0.600000 0 DOORS # Omt Door Type Space Stones U-Value Width Height Area Ft In Ft In 1 N Wood AHU 1 None .2 .1 .1 .1 ft' WINDOWS Orientation shown is the entered Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single Yes 0.58 0.24 N 48.0 ft' 6 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 E 1 Metal Low-E Single Yes 0.58 0.24 N 36.0 ft' 6 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 3 E 1 Metal Low-E Single Yes 0.65 0.21 N 48.0 ft' 6 ft 0 In 1 1t 4 in Drapes/blinds Exterior 5 4 S 2 Metal Low-E Single Yes 0.65 0.21 N 48.0 ft- 1 ft 6In 1 ft 4 in Drapes/blinds Exterior 5 5 S 2 Metal Low-E Single Yes 0.58 0.24 N 18.0 ft- 14 ft 0 in 1 ft 4 in Drapesblinds Exterior 5 _ 6 S 2 Metal Low-E Single Yes 0.58 0.24 N 48.0 ft- 14 ft 0In 1 It 4 in Drapes/blinds Exterior 5 _ 7 S 2 Metal Low-E Single Yes 0.33 0.16 N 21.3IF 14 It 0 In 1 ft 4 in Drapes/blinds Exterior 5 8 W 3 Metal Low-E Single Yes 0.33 0.16 N 18.7 ft- 14 ft 0In 1 It 4 in Drapes/blinds Exterior 5 _ 9 W 3 Metal Low-E Single Yes 0.65 0.21 N 72.0 ft' 14 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 _ 10 W 3 Metal Low-E Single Yes 0.58 0.24 N 36.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 11 W 3 Metal Low-E Single Yes 0.58 0.24 N 12.0 ft- 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 12 N 4 Metal Low-E Single Yes 0.58 0.24 N 12.0 ft- 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 2117/2020 8:37 AM EnergyGaugeG USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang 1/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 13 N 4 Metal Low-E Single Yes 0.58 0.24 N 18.0 IF 1 It 61n 1 It 4 in Drapeslblinds Exterior 5 14 N 4 Metal Low-E Single Yes 0.33 0.16 N 24.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 15 E 5 Metal Low-E Single Yes 0.33 0.16 N 24.0 ft' 1 ft 6 in 1 ft 4 in Drapeslblinds Exterior 5 16 E 5 Metal Low-E Single Yes 0.58 0.24 N 12.0 ft' 1 it 6 In 1 It 4 in Drapeslblinds Exterior 5 17 W 6 Metal Low-E Single Yes 0.58 0.24 N 36.0 ft' 1 ft 6 in 1 ft 4 in DrapesPolinds Exterior 5 _ 1S N 7 Metal Low-E Single Yes 0.58 0.24 N 48.0 ft' 1 It 6 in 1 It 4 in Drapeslblinds Exterior 5 _ 19 E 8 Metal Low-E Single Yes 0.58 0.24 N 16.0 ft' 1 It 6 In 1 It 4 in Drapeslblinds Exterior 5 _ 20 E 8 Metal Low-E Single Yes 0.58 0.24 N 12.0 ft' 1 ft 6ln 1 ft 41n Drapes/blinds Exterior 5 21 S 9 Metal Lrn E Single Yes 0.58 0.24 N 24.0 ft' 1 it 6 In 1 it 4 in Drapeslblinds Exterior 5 _ 22 S 9 Metal Low-E Single Yes 0.58 0.24 N 36.0 ft' 1 It 6 in 1 ft 4 in Drapes/blinds Exterior 5 _ 23 W 10 Metal Low-E Single Yes 0.58 0.24 N 18.0 ft- 10 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 _ 24 W 10 Metal Low-E Single Yes 0.58 0.24 N 24.0 ft' 10 It 0 in 1 It 4 in DrapesPolinds Exterior 5 _ 25 W 10 Metal Low-E Single Yes 0.58 0.24 N 32.0.ft- 10 ft 0In 1 ft 4 in Drapes/blinds Exterior 5 _ 26 W 14 Metal Low-E Single Yes 0.65 0.21 N 288.0 ft' 1 ft 6 in 1 ft 4 in Drapeslblinds Exterior 5 27 S 15 Metal Low-E Single Yes 0.65 0.21 N 48.0 ft' 1 it 6 In 1 it 4 in Drapeslblinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 812 ft- 812 ft' 36ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed.ACH(50) .000459 6368.1 349.6 657.48 .1759 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 34 kBtu/hr 1 sys#1 2 Electric Strip HeaV None COP:1 17 kBtu/hr 2 sys#2 _ 3 Electric Strip Heat/ None COP:1 17 kBtu/hr 3 sys#3 4 Electric Heat Pump/ None Single HSPF:10.3 17 kBtu/hr 4 Ductless COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Single SEER: 16 46.5 kBtufhr 1395 cfm 0.8 1 sys#1 2 Central Unit/ None Single SEER: 16 17.9 kBtu/hr 537 cfm 0.8 2 sys#2 3 Central Unit/ None Single SEER: 16 17.9 kBtu/hr 537 cfm 0.8 3 sys#3 4 Central Unit/ None Single SEER: 23 24 kBtulhr 720 cfm 0.8 4 Ductless 2/17/2020 8:37 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Soflware Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM j# System Type SubType Location EF Cap Use SetPM Conservation 1 Electric None Garage 0.98 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS —Supply-- ---Return--- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 200 ft- Attic 20 ft' Default Leakage AHU 1 (Default) c(Default) c 1 1 _ 2 Attic 6- 125 ft' Attic 13 ft' Default Leakage Attic (Default) c(Default) c 2 2 3 Attic 6 125 ft' Attic 13 ft- Default Leakage Attic (Default) c(Default) c 3 3 TEMPERATURES Programable[[XThermostat:N Ceiling Fans:Cooll Feb ([X�] Marf [X] Jun ] Jul [X� Aug [X� 1 Sep Oct k Oct HX Nov Nov Dec H Decec Venting [ ] Jan [ ] Feb [X] Mar Apr [ j May Jun 1 Jul E E) ] Aug E ] Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 6B 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft. Oft 0.3 AHU 1 Default(8 lbs/sq.ft. 0 fF oft 0.3 AHU 2 Defauft(B lbs/sq.ft. Oft' Oft 0.3 AHU3 Defauft(8 lbs/s .ft. 0 fF Oft 0.3 MINI SPLIT 2/17/2020 8:37 AM EnergyGauge® USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: NOEL RESIDENCE Builder Name: RAPHAEL HENRI Street: 12103 RNERBEND ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE , FL, Permit Number: Y U Owner. Jurisdiction: ST LUCIE COUNTY w x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed, shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be Installed to (including maintain permanent contact with the underside of above -garage subfioor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous Insulation Installed on the underside of Floor framing and extends from the boftorr to the top of all perimeter Floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fodures installed in the building thermal envelope shall Recessed light fixtures Installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -Floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed J sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilin s. I a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 2/17/2020 8:38 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location varies 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 106.3 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 5294 d) Room unit/PTAC EER e) Other varies 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.592 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.219 c) Area 7c. 1078.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.1 14. Heating system: Capacity 85.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 10.30 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10B1. 13.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 0.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwse, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 12103 RIVERBEND ROAD City/FL Zip: PORT ST LUCIE. FL 2/17/2020 8:37:47 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsofts Pro'ect Summary I AHN QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUCKCALCWOLCOM For. NOEL RESIDENCE, RAPHAELHENRI 12103 RIVERBEND ROAD, PORT ST LUCIE, FL 34984 N otes: Design Information Job: Date: FEB. 17, 2020 By: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF aDedy of range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23121 Btuh Structure 27465 Btuh Ducts 9372 Btuh Ducts 8240 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Stuh Piping 0 Btuh Equipment load 32493 Btuh Use manufacturer's data In Rate/swir�q multiplier Equipment load 0.95 33919 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4133 Btuh Ducts 3757 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cooling (none) Area (ft�) 2914 2914 Equipment latent load 7890 Btuh Volume (fta) 35970 35970 Air changes/hour 0.20 0.11 Equipment Total Load (Sen+Lat) 41609 Btuh Equiv. AVF (cfm) 118 63 Req. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6049J1 AHRI ref Coil TEM4AOC48S41++TDR AHRI ref 8676081 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 9.6 kW Sensible cooling 32550 Btuh Heating output 32842 Btuh Latent cooling 13950 Btuh Temperature nse 19 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Pj1^ wrLq! tooft• 2020-Fab-1708:35:03 ^• ^� ^••• Right-SulteO Universal 2019 19.0.08 RSL06101 Page 1 ...ft WACINOEL RESIDENCE WITH ICY AND SUNROOM.mp Calc = MJ8 Front Door faces: E - wrightsoft Pro'ect Summary AHU2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772A66-6796 Email: OLACKCALCS@AOLCOM Prooect Information For: NOEL RESIDENCE, RAPHAELHENRI 12103 RIVERBEND ROAD, PORT ST LUCIE, FL 34984 Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD 42 OF 70 OF 28 OF Job: Date: FEB. 17, 2020 By: Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 13396 Btuh Structure 10246 Btuh Ducts 2182 Btuh Ducts 3077 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 15579 Btuh Use manufacturer's data n Rate/swingg multiplier Equipment load 0.95 12657 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2446 Btuh Ducts 793 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cool (none) Area (ft2) 908 908 Equipment latent load 3239 Btuh Volume (ft3) 11992 11992 Airchanges/hour 0.39 0.21 Equipment Total Load (Sen+Lat) 15896 Btuh Equiv. AVF (cfm) 78 42 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trans Trade Trade TRANE Model Cond 4TTR6018B1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567552 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 3.7 kW Sensible cooling 12530 Btuh Heating output 12472 Btuh Latent cooling 5370 Btuh Temperature rise 19 OF Total cooling 17900 Btuh Actual air flow 597 cfm Actual air flow 597 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ti "ghtmoft' 2020-Feb•1708:35,03 ....... ! E .. RlphtSulte® Unlwmai 2019 19.O.OB RSW0101 Page 2 A ...It WACINOEL RESIDENCE WITH ICY AND SUNROOM.rup Celc= MJB Front Dcorlaces: E Project SJob: wSummary rightsofte U • y Date: FEB. 17, 2020 AH 3 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466.6796 Email: OUCKCALCS@AOL.COM For. NOEL RESIDENCE, RAPHAELHENRI 12103 RIVERBEND ROAD, PORT ST LUCIE, FL 34984 Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10867 Btuh Structure 10267 Btuh Ducts 2272 Btuh Ducts 3199 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13140 Btuh Use manufacturer's data n Rate/swingg multiplier Equipment load 0.95 12793 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2169 Btuh Ducts 835 Btuh Central vent (0 cfm) 0 Btuh Heat' Cooling A (none) Area (ft') 924 Equipment latent load 3004 Btuh Volume (fta) 9908 9908 Air changes/hour 0.37 0.20 Equipment Total Load (Sen+Lat) 15798 Btuh Equiv. AVF (cfm) 61 33 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018131 AHRI ref Coil TEM6AOB24H21++TDR 7567552 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 4.4 kW Sensible cooling 12530 Btuh Heating output 14962 Btuh Latent cooling 5370 Btuh Temperature rise 23 OF Total cooling 17900 Btuh Actual air flow 597 cfm Actual air flow 597 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrtghffiof!• 2020-Feb-17 08:35:03 ACC - . Right-Sulte® Unlvemal 2019 19.0.08 RSU08101 Page 3 ...It WdACINOEL RESIDENCE WITH ICY AND SUNROOM.mp Cale = MJ8 Fmnt Door Laces: E Job: wProject Summary MINI SPLIT ry Byte: FEB. 17, zozo QUICK CALCS, INC. 317 ST LUCIE LANE:. FORT FL 34946 Phone: 772-4666799 Fax 772-4666796 Email: For. NOEL RESIDENCE, RAPHAELHENRI 12103 RIVERBEND ROAD, PORT ST LUCIE, FL 34984 Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TO Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 11550 Btuh Ducts 2113 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 13663 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Area ft Heating Cooliinng Volumea(W) 7540 7540 Air changes(hour 0.39 Equiv. AVF (cfm) 48 0.21 26 Heating Equipment Summary Make C&H Trade Model (1 CH-18SPHMW-230 AHRI ref 205263886 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 24 OF Backup: 10.3 HSPF 24000 Btuh @ 47°F O 767 cfm 0.056 cfm/Btuh 0 in H2O Input = 4 kW, Output = 13385 Btuh, 100 AFUE 90 OF 75 OF 15 OF M 50 % 61 gdlb Sensible Cooling Equipment Load Sizing Structure 16170 Btuh Ducts 1617 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 16898 Btuh Latent Cooling Equipment Load Sizing Structure 4083 Btuh DuctsBt 8 Centrral vent (0 cfm) 0 Btuh (none) Equipment latent load 4887 Btuh Equipment Total Load (Sen+Lat) Req. total capacity at 0.70 SHR 21785 2.0 Btuh ton Cooling Equipment Summary Make C&H Trade Cond H-18SPHMW-230 Coil 2(1)CCH-09MSPHWM AHRI ref 205263886 Efficiency 12.5 EER, 23 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 767 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.78 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrtgtfisC - 2020-Feb-1708:35:03 •--- RightSuite® Universal 2019 19.0.08 RSU08101 Page 4 ACM ...ft WNAMNOEL RESIDENCE WITH ICY AND SUNlROOM.mp Calo = MJS Front Doortaces: E •. 'F ' wrightsoft• Right-M Worksheet Job: AHU 9 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772-466-6796 Email: OUICKCALCS@AOLCOM 1 Room name AHU 1 IOTCHFN 2 Exposed wall 132.3 ft 1.0 a 3 Room height 12.3 It 13.0 It heatfcool 4 Room dimensions 1.0 x 555.5 ft 5 Room area 2913.5 ft' 565.5 W Ty Construction U-value Or HTIA Area (01) Load Area (R') Load number (Btuh/ftz°F) (Btuhlft2) or perimeter Qt) (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross WKS Heal Cool Gross WP/S Heat Cool 6 UN 13A-4ocs 0.143 n 4.00 2.19 280 226 905 494 0 0 0 0 LG 2glazing, dr loxe 0.650 n 18.20 14.99 54 0 983 810 0 0 0 0 w 13A4ocs 0.143 no, 4.00 2.19 59 42 168 92 0 0 0 0 L-G 2 glazing, dr lave 0.650 ne 18.20 26.88 18 0 318 470 0 0 0 0 11 VE-C 13A400s 0.143 a 4.00 2.19 413 317 1269 694 0 0 0 0 2 glazing, dr lave 0.650 a 18.20 . 33.77 96 0 1747 3242 0 0 0 0 W r 13A4ocs 2 lave 0.143 0.650 se 4.00 18.20 2.19 27.05 59 18 42 0 168 318 92 473 0 0 0 0 0 0 0 0 W, t glazing, clr 13A4ccs 0.143 se s 4.00 2.19 313 241 965 527 13 13 52 28 I-G 2 glazing, clr Iowa 0,650 s 18.20 16.03 72 0 1310 1154 0 0 0 0 w 13A4ocs 0.143 sw 0.00 0.00 0 0 0 0 0 0 0 0 V1J 1 13A4gcs 0.143 w 4.00 2.19 550 502 2010 1098 _ 0 0 0 0 2 glazing, dr lorve 0.650 w 18.20 33.77 48 0 874 1621 0 0 0 0 W 13A4as 0.143 ow 0.00 0.00 0 0 0 0 0 0 0 0 C 16D-30td 0.032 - _0.00 0.00 0 0 0 0 _ 0 0 0 0 C 16K30.Otd 0.408 - 1.18 0.79 2914 2914 3433 2309 565 566 666 448 F i 22A-tph 1.358 - 38.02 0.00 2914 132 5032 0 566 1 38 0 6 c)AED excursion 0 -155 Envelope bss/gain 19501 13076 756 322 12 a) IMNralion 3620 1039 28 8 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 0 0 0 0 Applianceslother 13350 4000 Subtotal (lines 6 to 13) 23121 27465 785 4330 Less external load 0 0 0 0 Less trensfer 0 0 0 0 Redistributbn 0 0 57 37 14 Subtotal 23121 2746 5 842 4367 15 Duct loads 41% 30% 9372 8240 41% 30% 341 1310 Trial room load 32493 35705 1183 5677 Air required (rim) 1550 1550 56 246 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r 'pwwr!9hGgo.- 2020-Feb-1708:35:03 CRight-SufteO universal 2019 19.0.08 RSL08101 Page 1 ...ft HJAC\NOEL RESIDENCE WITH ICY AND SUNROOM.nup Calc = MJB Front Door faces: E wrightsoft' Right-M Worksheet Job: AHU' Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 STLUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name FAMILY ROOM AHU 1 CLST 2 Exposed vrall 40.0 ft 0 ft 3 Room height 15.0 0 hwVcool 10.0 ft heWmd 4 Room dimensions 1.0 x 395.0 ft 3.0 x 7.0 fit 5 Room area 395.0 fF 21.0 fF Ty Constn otlon U-value Or HTM Am (ft2) Load Area Load number (Bluh/ftMF) (Bluh/112) or perimeter qt) (Btuh) or perimeter (fi) (Btuh) Heat Cool Gross WP/S Heat Cool Gras MP/S Heat Cool 6 1R/ 13A-4ccs 0.143 In 4.00 2.19 0 0 0 0 0 0 0 0 I--G 2 glazing, cir lave 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 13A400s 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 YI -G 2 alazino, dr to - 0.650 no 18.20 26.88 0 0 0 0 0 0 0 0 11 ,W I 13A4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 L--C' 2glazing, clr 11 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 WL13A4xs 0.143 se 4.00 2.19 0 0 0 0 0 0 0 0 G 2glazing, Gr Iowa 0.650 se 18.20 27.05 0 0 0 0 0 0 0 0 14J 13A400s 0.143 s 4.00 2.19 300 22B 913 499 0 0 0 0 L-G 2 glazing, cir low-e 0.650 s 18.20 16.03 72 - 0 1310 1154 0 0 0 0 w 13A4cos 0.143 sw 0.00 0.00 0 0 0 0 0 0 0 0 VN 13A ws 0.143 w 4.00 2.19 300 300 1201 655 0 0 0 0 L-G 2glazing, cIr iwue 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 w 13A4acs 0.143 nw ROD 0.00 0 0 0 0 0 0 0 0 C 16D-30td 0.032 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16X30-Md 0.403 - 1.18 0.79 395 395 465 313 21 21 25 17 F 22A-tph 1.358 - 38.02 0.00 395 40 1521 0 21 10 0 0 6 c)AED excursion 71 -1 Envelops lossfgain 5411 2693 25 16 12 a) Infiltration 1297 372 0 0 b) Rcomvardilation 0 0 0 0 13 Internal gams: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (fines 6 to 13) 6ma 3065 25 16 Less edenal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 4 2 -25 -16 14 Subtotal 6712 3W8 0 0 15 Duct Inds 41% 30% 2720 920 41% 30Y/Y 0 0 Trial room load 9432 3988 0 0 Air required"nol 450 173 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -4� wrlghesoie- 2020-Feb-17 08:35:03 ,ZUK" " ""' RightSuite® Universal 2019 19.0.08 RSU08101 Page 2 ...it FMAC\NOEL RESIDENCE WITH ICY AND SUNROCM.rup Calc = MJB Front Door faces: E wrightsoft, Right-M Worksheet Job: AHU 1 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Emall: OUICKCALCS@AOL.COM 1 Room name OFFICE FOYER 2 Exposed wan 17.2 ft 7.0 0 3 Room height 14.0 ft heatfcool 13.0 ft heat/cool 4 Room dimensions 1.0 x 229.5 fl 1.0 x 164.0 ft 5 Room area 229.5 ft' 164.0 it - Ty Construction number U-value (Bluth IF) Or HTM (EtuwftT Area (W) or perimeter (ft) Load (Bluh) Area 012) or perimeter Qt) Load (Bluh) Heal Cool Gross WP/S Heat Cool Gross WP/S Heal Coal 6 11 N/ L-G 13A4acs 2 glazing, cir lave 13A-4= 2 almino. cir lave_ 13A4ocs 0.143 0.650 0.143 0.650 0.143 n n ne no a 4.00 18.20 4.00 18.20 4.00 2.19 14.99 2.19 25.88 2.19 0 0 59 18 182 0 0 42 0 158 0 0 168 318 633 0 0 92 AIM 346 0 0 0 0 91 0 0 0 0 43 0 0 0 0 172 0 0 0 0 94 W Vf! L- G W I-G 2 glazing, clr Iw✓e 13A-4acs 2 glazing, cIr lc to 0.650 0.143 0.650 e. se se 18.20 4.00 18.20 33.77 2.19 27.05 24 0 0 0 0 0 437 0 0 811 0 0 48 0 0 0 0 0 874 0 0 1621 0 0 W I 13A4ocs 2 glazing, cir low-e 13A4ms 13A4ocs 2 glazing, dr la - 0.143 0.650 0.143 0.143 0.650 s a sw w w 4.D0 18.20 0.00 4.00 18.20 2.19 16.03 0.00 2.19 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W W L-C W C 13A4acs _ 16D.30td 0.143 0.032 mu - 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 C 16=41[d 0.408 - 1.18 0.79 230 230 270 182 164 164 193 130 F i 22Atph 1.358 - 38.02 0.00 230 17 653 0 164 7 266 0 6 c)AED excursion -92 1 Envelope loss/gain 2479 1809 15D5 1846 12 a) Infiltration 522 150 197 56 b) Roomventilation 0 0 0 0 13 Internal gams: Occupants @ 230 0 0 0 0 Appliamesfother 600 600 Subtotal (fines 6 to 13) 3001 2558 1702 2503 Less exteml load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 543 799 -1702 -2503 14 Subtotal 3544 3357 0 0 15 Dud loads 41% 30% 1436 1007 41% 30% 0 0 Total mom Imd 4g80 43M 0 0 Air required (dm) 238 189 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -FW"' wrlah fc- 2020-Feb-1708:35:03 lem - ^.-^ RightSuite®Untemal201919.0.08RSW8101 Page ...it WAMNOEL RESIDENCE WITH ICY AND SUNROOM.mp CaIc=MJ8 Front Doorfaces: E wrightsoft Right-J®Worksheet Date; AHU 1 Date: FEB. 17, zozo By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name LMNG ROOM HALLWAY 2 3 Exposed wall Room height 0 ft 15.0 It heaNcool 0 ft 10.0 ft heat/cad 4 5 Room dimensions Room area 1.0 x 167.0 ft 167.0 ft' 1.0 x 104.0 ft 104.0 ft- Ty Constriction number U-value (BtuWft;°F) Or HTM (Bluh/ft� Area W) or perimeter (ft) Load (81uh) Area (112) or perimeter (ft) Load (Bluh) Heat I Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 11 UN L-- G 13A-4acs 2 gh¢irg, clr.Iv 13A4ocs 2 glazing, dr 1cwe "1344ccs 2 gluing, clr hive 13A-0acs 2 glazing, dr lcea 13AAws 2 glazing, cir lame 13AAocs 13A-4ocs 2glazirg, dr loxe 13AAccs 16D Wd -0.143 0.650 0.143 0.650 0.143 0.650 0.143 0.650 0.143 0.650 0.143 D.143 0.650 0,143 0.032 n n ne no a a se se s s sw w w nw - 4.00 18.20 4.00 18.20 4.00 18.20 4.00 1&20 4.00 18.20 0.00 4.00 18.20 0.00 0.00 2.19 14.99 2.19 26.88 '2.19 33.77 2.19 27.05 2.19 16.03 0.00 2.19 33.77 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 01 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 W " Y-G W L-C V,J LG W W• I-G W C C F 16)C30-0td 22A4ph 0.408 1.358 - - 1.18 38.02 0.79 0.00 167 167 167 '0 197 0 132 0 104 104 104 0 123 0 82 0 6 o)AED excursion -91 -3 Envelope loss/gain 197 41 123 80 12 a) Intimation 0 0 0 0 b) Rcomwntilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancesrother 2500 0 Subtotal(rines 6to 13) 197 2541 123 80 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 616 905 -123 -80 14 Subtotal 812 3447 0 0 15 Dud loads 41% 30% 329 103 4 41% 30% 0 0 Total room load 1142 4481 0 0 Air required(dm) 54 195 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrign1!!n [- 2020-Feb-17 06:35:03 AC k -' "'"' RightSuiteO Universal 2019 19.D.08 RSLI08f01 Page 4 ...It WACINOEL RESIDENCE WITH ICY AND SUNROOM.rup Calc = MJB Front Door faces; E f w�ightsoft° RighW@ Worksheet Job: AHU 1 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34948 Phona: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS(r9AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area DINING ROOM 14.2 ft 14.0 It healccol 1.0 x 229.5 it 229.5 W LAUNDRYROOM 19.0 It 10.0 ft heat/cool 1.0 x 237.0 it 237.0 f 2 Ty Constriction' number U-value (Btuldit;°F) Or HTM (Btulvft2) Area M or perimeter (ft) Load (&uh) Area (ft' or perimeter (it) Load (Bluh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 11 %L-G 13A-4ws 2glazing, or lo*e 13A4ocs 2 glazing. dr lov-e 13A-4ws 2 glazing, dr love 13A-0acs 2 glazing, dr lame 13A4ocs 2 glazing, clr low-e 13A4ocs 13A-4ocs 2 glazing, dr lave _ 1344ocs '16D-Md 0.143 0.65) 0.143 0.650 0.143 0.650 0.143 0.650 0.143 0.650 0.143 0.143 0.650 0.143 0.032 n n ne ne a a se se s s sw w w mw - 4.00 18.20 4.00 18.20 4.00 18.20 4.00 18,20 4.00 18.20 0.00 4.00 18.20 0.00 0.00 2.19 14.99 2.19 26.88 - 2.19 33.77 2.19 27.05 2.19 16.03 0.00 2.19 33.77 0.00 0.00 0 0 0 0 140 24 59 18 0 0 0 0 0_ 0 0 0 0 0 0 116 0 42 0 0 0 0 0 0 0 0 0 0 0 0 464 437 168 318 0 0 0 0 0 0 0 0 0 0 0 254 811 92 473 0 0 0 0 0 0 0 150 36 -- 0 0 0 0 0 0 0 0 0 40 0 0 0 114 0 0 0 0 0 0 0 0 0 0 40 0 0 0 456 655 0 0 0 0 0 0 0 0 0 160 0 0 0 249 540 0 0 0 0 0 0 0 0 0 88 0 0 0 W " W V,lr LG Y-G W W LC W C C F 161O0-0td 22A-lph 0.408 1.358 - - 1.18 38,02 0.79 0.00 230 230 230 14 270 539 182 0 237 237 237 19 279 722 18B 0 6 a)AED e=sslon -61 -41 Envelope bsstgain 2197 1750 2274 1024 12 a) Infiltration 431 124 411 118 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Applianceslother 0 0 600 0 0 0 Subtotal (lines 6 to 13) 2628 2474 2694 1141 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistdbul'an Sub total 591 3218 829 3W4 11 2695 7 ill* 15 Duct Iwds 41% 30% 1304 991 41% 30°/a 1093 345 Tdal IFcm load 4523 4215 3788 1493 Air required (dm) 216 1S6 181 65 f�+- wrlgFta[r9of'e- 2020-Feb-17 08:35:03 ,4CC Right -Suite® Universal 2019 19.0.08 RSU08101 Page 5 ...� HVAC%NOEL RESIDENCE WITH ICY AND SUNROOM.rup Calc = MJB Fmnt Door feces: E wrightsoft- Right-M Worksheet Jab: AHU 1 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC 2 PRAYER ROOM 2 Exposed wan 4.0 It 0 It 3 Room height 10.0 g heat1cocl 10.0 It heat/cod 4 Room dimensions 11.0 x 4.0 ft 4.0 x 4.0 ft 5 Room area 44.0 fF 16.0 fi' Ty Construction number U-value (Btuh/f MF) Or HTM (&uM117) Area (fly or perimeter (ft) Load Pub) Area 00 or perimeter at) Load (Bluh) Heat I Cool Gross WP/S Heat Cool Gross WP/S Heal Cool 6 11 Mr L-G 13A-0acs 2 glazing, clr lave 13A4ocs 2 alazim. clr low-e 1aA4acs 0.143 0.650 0.143 0.6E0 0.143 n n ne no a 4.00 1&20 4.00 18.20 4.00 2.19 14.99 2.19 25.88 2.19 40 0 0 0 -a 40 0 0 0 0 160 0 0 0 0 88 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 1--G W `G W, L-G 2 glazing, dr lc , e. 13A-flocs 2 glazing, cir lave 0.650 0.143 O.650 a se se 18.20 4.00 1&20 33.77 2.19 27.05 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 0 1N t-O 13A-0acs 2 glazing, clr Iowa 0.143 0.650 s s 4.00 18.20 2.19 16.03 0 0 0 0 0 0 0 0 0 a 0 0 0 0 a 0 w W �G 13A4ocs 13AAccs 2 glazing, co- love 0.143 0.143 0.650 sw w w 0.00 4.g0 18.20 0.00 2.19 33.77 0 0 0 a 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 0 0 0 0 w C 13AAccs 16D-Mc! 0.143 0.032 w - 0.00 0.00 0.00 0,00 0 0 0 0 0 0 0 0 a 0 0 0 0 0 a a C 16X30Otd 0.408 - 1.18 0.79 44 44 52 35 16 16 19 13 F 22htph 1.358 - 31102 0.00 44 4 152 0 16 0 0 0 fi c)AED excursion -22 -18 Envelope IcWgain 361 100 19 S 12 a) Infiltration 86 25 0 0 b) Roomventiation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliamestother 500 500 Subtotal (lines 6 to 13) 1 451 625 19 415 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 451 625 19 495 15 Ductloads 41% 30% 183 187 41% 30%n 8 148 Totalrmmlcad 633 812 26 643 Air required (rim) 30 35 1 28 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -F* wri9F,•tvott- 2020-Feb-1708:35:03 -' Right -Suite® Universal 2019 19.0.08 RSU08101 Page 6 ...It WAC1NOEL RESIDENCE WITH ICY AND SUNROOM.rup Calc=MJB Front Doorfaces: E wrightsoftRighW@ Worksheet Job: AHU 1 Date: FEB. 17, zozo By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS®AOL.COM 1 Room name PANTRY BEDROOM 2 2 Fxgxrsed wall 0 It 9.0 it 3 Room height 10.0 It heat1ccol 10.0 R heat/cod 4 Room dimensions 8.0 x 6.0 ft 15.0 x 14.0 1t 5 Room area 48.0 it' 210.0 it - Ty Construction U-value Or HTM Area (11= Load Area (02) Load number (Btuh/ft? r) (&uhlft� or perimeter lit) (Ruh) or perimeter qt) (Dub) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 Y--G 13A-0acs 0.143 In4.00 2.19 0 0 0 0 90 72 288 158 2 glazing, clr laves 0.650 n 18.20 ,14.99 0 0 0 0 16 0 328 270 w L-G 13A-4acs 2 I 0.143 0.650 ne 4.00 18.20 2.19 26.88 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 w " plazino, clr -e 13A4acs 2 1. 0.143 0.650 ne a 4.00 18.20 2.19 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 w i--G glazing, cIr 134-0acs 2 glazing, dr love 0.143 0.650 a se se 4.00 18.20 2.19 27.05 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 141 13A4ws; 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 Y- G 2 glazing, dr lc / e 0.650 s 18.20 16.03 0 0 0 0 0 -0 0 0 IN 13A-4ccs 0.143 sw 0.00 0.00 0 0 0 0 0 0 0 0 I iSJ 13AAws 0.143 w 4.00 2.19 0 0 0 0' 0 0 0 0 LC 2 glazing, clr Iw 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 w 13A4ccs 0.143 ma 0.00 0.00 0 0 0 0 0 0 0 0 C 16D-301d 0,032 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16)CM-Md 0.408 - 1.18 0.79 48 48 57 38 210 210 247 166 F 22A4ph 1.358 - 38.02 0.00 48 0 0 0 210 9 342 0 6 c)AED esursion -19 -66 Envelope bssrgdn 57 19 12D6 628 12 a) Infillodion 0 0 195 56 b) Roomventifation 0 0 0 0 13 Internet gains: Occupants 0 230 0 0 0 0 Appliances/other 500 1250 Subtotal (Ines 6 to 13) 57 519 1400 1834 Less edema) load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 17 11 2 2 14 Subtotal 73 530 1403 1836 15 Duct loads 41% 30% 30 159 41% 3D% 569 551 Total mom load 103 689 1971 2386 Air raquirsd (dm) 5 30 94 104 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. `;,`!,!;Lg!?�� 2020-Feb-17 08:35:03 A&A Right-Suite4a Unwrsal 2019 19.0.08 RSU08101 Page 7 ...It WACINOEL RESIDENCE WITH ICY AND SUNROOM.wp Celc = MJB Front Door faces: E Wrightsoft Right-M) Worksheet Dat AHU 1 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM i Room name BATH 2 BEDROOM 3 2 FCgwed wall 0 ft 15.0 0 3 Room height 10.0 It healfccol 10.0 ft heatf000l 4 Room dimensions 6.0 x 7.0 It 15.0 x 15.0 ft 5 Room area 42.0 fP 225.0 fF Ty Construction U-value Or HTM Area (g') Load Area (it) Load number (Btuh/ftMF) (Btuh/ft2) or perimeter (it) (Bluh) or perimeter (ft) (Bluh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heal Cool 6 1p! �C 1341ocs 2ghuirg, clr low-e 0.143 0.650 n In 4.00 1&20 2.19 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 w I--G 13A4ocs 2elazina. clrlome- 0.143 0.650 na ne 4.00 18.20 2.19 26.88 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 W 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 L--G W, t-+ 2 glazing, dr Irnve 13AAws 2glazing, dr lore 0.650 0A43 0.650 a se se 18.20 4.00 18.20 33.77 2.19 27.05 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 tI!N 13AAms glazing, clr lore 0.143 0.650 s s 4.D0 _ 18.20 2.19 16.03 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -'2 w W L--G. 13AAocs 13A4ocs 2 glazing, dr lore 0.143 0.143 _ 0.650 sw w w 0.00 4.00 18.20 0.00 2.19 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 15D 36 0 114 0 0 456 655 0 249 1216 w 13A4ocs 0.143 my 0.00 0.00 0 0 0 0 0 0 0 0 C 16D301d - 0,032 - 0.00 0.00 0 0 0 0 0 0 0 0 c 16K1001d 0.408 - 1.18 0.79 42 42 49 33 225 225 265 178 F i 22A4ph 1.356 - 38.02 0.00 42 0 0 0 225 15 Sm 0 6 c)AED excursion -18 435 Envelope lass/gain 49 15 1947 2079 12 a) Infiltration 0 0 324 93 b) RcomventiHiion 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appfancesrother 5m 0 Subtotal (lines 6 to 13) 49 515 2271 2172 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 0 49 0 515 0 2271 0 2172 15 Duct leads 41% 30°/ 20 154 41% 30% 921 652 Torroom load 70 669 3192 2823 Air required (cfm) 3 29 152 123 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrlgF,tGsoR- 2020-Feb-1708:35:03 RightSuite® Universal 2019 19.0.08 RSL08101 Page 8 ...ft WAMNOEL RESIDENCE WITH ICY AND SUNROOM.rup Calc = MJ8 Front Door faces: E wrightsoft Right -A) Worksheet Job: AHU 1 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUCKCALCS@AOL.COM 1 Room name SINKS 2 BATH 3 2 Egxsed wall 0 ft 6.0 ft 3 Room height 10.0 It hwtt=l 10.0 ft heaVcod 4 Room dimensions 7.0 x 7.0 ft 6.0 x 10.0 ft 5 Room area 49.0 fF 60.0 fP Ty Construction U-value Or HTM Area (n� Load Area (it-) Load number (Btuh/ftMF) (Btuhft� or perimeter (it) (Bluh) or perimeter 01) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 UN i. 13AAous 0.143 In 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, clr love 0.650 n 18,20 . 14.99 0 0 0 0 0 0 0 0 -;, 13A4ccs 0.143 ne 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing. clr lave 0.650 me 18.20 28.88 0 0 0 0 0 0 0 0 11 W 13A-0acs - 2 Or lone 0.143 0.650 a 4.00 18.20 2.19 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 w glazing, 13A-4ws 2 glazing, dr lave 0.143 0.650 a se se 4.00 18.20 2.19 27.05 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 0 1R! 13A-4ccs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 L-C 2 glazing, clr love 0.650 s 18.20 16.03 0 0 0 0 0 0 0 0 w 13AAocs 0.143 sw 0.00 0.00 0 0 0 0 0 0 0 0 W! 13AAws 0.143 w 4.00 2.19 0 0 0 0 60 48 192 105 L-C 2 glazing, clr lwue 0.650 w 18.20 33.77 0 0 0 0 12 0 218 405 w 13A4ocs 0.143 mw 0.00 0.00 0 0 0 0 0 0 0 0 C 16D-Md 0.032 - 0.00 coo _ 0 0 0 0 0 0 0 0 C 16X30-Qd 0.408 - 1.18 0.79 49 49 58 39 60 60 71 48 F I' 22A4ph 1.358 - 38.02 0.00 49 0 0 0 60 6 228 0 6 c)AED excursion -19 145 Envelope losstgain 58 20 709 702 12 a) Infiftration 0 0 130 37 b) Roomventiblion 0 0 0 0 13 Irdemal gains: Occupants 230 0 0 0 0 Appliances/other 600 0 Subtotal (tines 6 to 13) 58 520 839 740 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 9 6 0 0 14 Subtotal 66 525 839 740 15 Duct loads 41% 30% 27 153 41% 30% 340 222 Trial rmm load 93 684 1179 961 Air required (cfm) 4 30 56 42 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. s =!-gm -tm- 202U Feb-17 08:36:03 RlghtSuite® Universal 2019 19.0.08 RSL08101 Page 9 ...It HJAC%NOEL RESIDENCE WITH ICY AND SUNROOM.rup Calc = MJB Front Door faces; E wrightsoft• Right-M) Worksheet Job: AHU 1 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCSQAOL.CCM 1 Room name WIC CABANA BATH 2 Exposed wall 0 ft 0 It 3 Room height 10.0 R heat/cool 10.0 It heaVmol 4 Room dimensions 6.0 x 5.0 It 7.0 x 11.0 ft 5 Room area 30.0 fP 77.0 fP Ty Constriction number U-value (Btuhdft;*F) Or HTM (Blaww) Area Yt) or perimeter (ft) Load (Btuh) Area (fib or perimeter III) Load (Bluh) Heat Cool Gross WPlS Heat Cool G. WP/S Heat Cool 6 1(Y I-C 13A4ccs 2 glazing, dr low-e 0.143 0.650 0.143 n n n e 4.00 18.20 4.00 2.19 14.99 2.19 0 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 t13A-4ocs 11 -C ly 2 alaz(ro, clr kwo 13A-0xs 0.650 0.143 ne a 18.20 4.00 26.88 2.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - w I--G 2 glazing, cIr lone 13A4ocs 2 glazing, cIr lows 0.650 0.143 0.650 a se $e 18.20 4.00 18.20 33.77 2.19 27.05 0 0 0 0 0 0 0 0 0 0 0 0 . 0 0 0 0 0 0 0 0 0 0 0 0 VN t-O 13A 4ccs 2 glazing, cIr love 0.143 0.650 s s 4.00 18.20 2.19 16.03 0 0 0 0 0 0 _ 0 0 0 0 0 0 0 0 0 0 W IM _. I---C 13A4ocs 13A-4ocs 2 glazing, cIr love 0.143 0.143 0.650 sw w w 0.00 4.00 18.20 0.00 2.19 33.77 0 0 a 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 w C 13AAccs 11 0.143 0.032 aw - 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X3flgld 0.408 - 1.18 0.79 30 30 35 24 77 77 91 61 F 2ZA4ph 1.358 - 3&02 -0.00 30 -0 0 0 77 0 0 0 6 c)AED excursion -18 -30 Envelope loss/gain 35 6 91 31 12 a) Infiltration 0 0 0 0 b) Raomventibtlon 0 0 0 0 13 Internal gams: Occupants 230 0 0 0 a Applances/other 500 800 Subtotal (fines 6 to 13) 35 6w 91 831 Less external load 0 0 0 0 Less tramfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 35 506 91 831 15 Duct loads 41% 30Wo 14 152 41% 30% 37 249 TUal room Imd 50 657 128 1081 Air required (,an) 2 29 6 47 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrrgFirCsoTt^ 2020-Feb-1708:35:03 A' k - '"" """' RightSufte® Universal 2019 19.0.08 RSW8101 Page 10 ...It WACWOEL RESIDENCE WITH ICY AND SUNROOM.rup Calc=MJ8 Front Oooffaces: E wrightsoft Right-M Worksheet Job: AHU 2 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-468-6796 Email: QUICKCALCS@AOL.CCM 1 Room name AHU 2 THEATRE 2 Fused wall 81.3 ft 33.2 it 3 Room height 13.2 It 130 ft heat/wol 4 Room dimensions 1.0 x 281.5 ft 5 Room area 908.0 fP 281.5 ft' Ty Construction U-value Or HTM Area (g2) Load Area (ft� Load number (Btuhtft�*F) (SIuhlft5 or perimeter (ft) Ruh) or perimeter (ft) (Duh) Heat Cool Gnus WP/S Heat Ccol Gross WPIS Heat Cool 6 %L-G 13A-0ars 0.143 n 4,00 2.19 370 322 1289 705 - 130 130 521 284 2glazing, cIr Iw 0650 n 18.20 14.99 48 0 874 720 0 0 0 0 W, 13A-4acs 0.143 ne 4.00 2.19 55 55 221 121 55 55 221 121 t-G 2 plazfnn, clr love 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 W 13A-4ws- _ 0.143 a 4.00 2.19 337 301 1205 659 247 247 989 540 L--G 2 glazing, clr Ivv-e 0.650 a 18.20 33.77 36 0 655 1216 0 0 0 0 13A4ws 0.143 se 0.00 0.00 0 0 0 a 0 0 0 0 Y-a 2 glazing, clr love 0.650 se 0.00 0.00 0 a 0 0 0 0 0 0 Url 13A-4ms 0.143 s 0.00 0.00 0 0 0 0 0 a 0 0 L--G z glazing, ar Ia 0.650 s 0.00 0.00 - a 0 0 0 0 0 0 0 w 13A-4acs 0.143 sw 0.00 0.00 0 0 0 0 0 0 0 0 w 13AAws 0.143 w 4.00 2.19 285. 201 8% 440 0 0 0 0 T-G z glazing, ch Iowe 0.650 w 18.20 33.77 84 0 1529 2837 0 a 0 0 w 13A4ws 0.143 nv 4.00 2.19 64 64 255 139 0 0 0 0 C 16D-Md 0.032 - 0.00 0.00. 0 0 0 0 a 0 0 0 C 16X30atd 0.408 - 1.18 0.79 908 908 1070 720 282 282 332 223 F 2241ph 1.3M - 38.02 0.00 906 81 3093 0 282 33 1261 0 6 c)AFD mcursien Sw -176 Envelope 6ossfgain 109% 8057 3323 992 12 a) Infiltration 2401 689 934 268 b) Roomverdilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 1500 1500 Subtotal Ones 6 to 13) 13396 10246 4257 2761 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 462 489 14 Subtotal 13395 10246 4720 3249 15 Duct loads 169% 3(Y 2182 3077 ll 30% 769 976 Total mom load 15579 13323 5488 4225 Air required tofm) 597 597 210 189 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrlgF�is-of'e- 2020-Feb-17 08:35:03 I&k' RlghtSuite@ Universal 2019 19.0.08 RSUJB101 Page 11 ...ft FMACINOEL RESIDENCE WITH ICY AND SUNROOM.mp Calc = MJ8 Front Door faces: E wrightsoftC Right-J® Worksheet Job: IY!"I U 2 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772-466-6796 Email: OUCKCALCS@AOL.COM 1 Room norm GAME ROOM HALL 2 Exposed wall 39.2 It 4.0 It 3 Room height 15.0 0 heat/cool 10.0 ft heat/cad 4 Room dimensions 1.0 x 413.5 fl 1.0 x 157.0 It 5 Room area 413.5 ft' 157.0 f 2 Ty construction LLvalue Or HTM Area (fly Load Area (fl2) Load number (Btuh/11VIF) (Bluh/ft� or perimeter (fQ (Bluh) or perimeter (ft) (61uh) Heal Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 VN 13A4ocs 0.143 n 4.00 2.19 240 192 769 420 0 0 0 0 L-G 2 glazing, clr love 0.650 n 18.20 14.99 48 0 874 720 0 0 0 0 IN 13AAa 0.143 no 4.00 2.19 0 0 0 0 0 0 0 0 L-G 2 0lazino. clr lave 0.650 ne 0.00 0.00 0 0 0 0 0 0 0 0 11 l4/ 13A-4ms 0.143 a 4.00 2.19 0 0 0 0 40 16 64 35 L-G 2 glazing, clr lorry 0.650 a 18.20 33.77 0 0 0 0 24 0 437 811 w L G 1344ocs dr lave 0.143 0.650 se 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �q! 2 plazing, 13A4ms 0.143 se s 0.00 0.00 0 0 0 0 0 0 0 0 t-G 2 glazing, cir low-e 0.650 s 0.00 0.00 0 0 10 0 0 0 0 0 w 13AAa 0.143 sw 0.00 0.00 0 0 0 0 0 0 0 0 WJ , 13A-4ws 0.143 w 4.00 2.19 285 201 so 440 0 0 0 0 L-G 2 glazing, cir tome 0.650 w 18.20 33.77 84 0 1529 2837 0 0 0 0 w 13A4o 0.143 mr 4.00 2.19 64 64 255 139 0 0 0 0 C 16D-30td 0.032 - 0.00 0.00 0 0 0 0 0 _ 0 0 0 C 16X.30{ltd 0.408 - 1.18 0.79 414 414 487 328 157 157 185 124 F 22Mlph 1.358 - 38,02 0.00 414 39 1489 0 157 4 152 0 6 c)AED excursion 708 -17 Envelope loss/gain 6207 5592 838 953 12 a) Infiltration 1272 365 86 25 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliames/other 0 0 Subtotal (fines 6 to 13) 74M 5957 924 978 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 142 150 -924 -978 14 Subtotal 7622 6107 0 0 15 Dud loads 16% 30% 1242 1834 16°/a 30% 0 0 Total room load U54 7941 0 0 Air required(dm) 340 356 0 0 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. wrrge?! an- 2020-Feb-17 08:35:03 �A ^" Right -Suite® Universal 2019 19.0.08 RSU08101 Page 12 ... ItWVACWOEL RESIDENCE WITH ICY AND SUNROOM.rup Calc=MJB Front Doorfaces: E fj+ wrightsoft' Right-JO Worksheet Job: AHU 2 Date: FEB. 17, 20z0 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name AMU 2 CLST HALF BATH 2 F_grosedl wall 0 It 5.0 If 3 Room height 10.0 It heat(ccol 10.0 It hewcool 4 5 Room dimensions Room area 4.0 x 4.0 ft 16.0 fP 5.0 x 8.0 It 40.0 fP Ty Construction U-value Or HTM Area (N2) Load Area (0') Load number (Btuhfftz*F) (Btuh/ft2) or perimeter Of) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 UN- LC W 13AAocs 2 glazing, clr lox a 13A-4ccs 0.143 O.650 0.143 n n ne 4.00 18.20 4.00 2.19 14.99 2.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 L-� G W I--G W L-G 2 r inn, co- to r¢ 13A4ocs 2 glazing, cIr Iove 13A-flocs 2 glazing, cIr loxe 0.650 0.143 0.650 0.143 0.650 ne a a as as 0.00 4.00 18.20 0.00 0.00 0.00 2.19 33.77 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 50 12 0 0 0 38 0 0 0 0 152 218 0 0 0 83 405 0 0 t-G 13A4ocs z glazing, ar low-e 0,143 0.650 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W �! L--G 13A-4ocs 13AAocs 2glazing, cIr lore 0.143 0.143 0.650 sw w w 0.00 4.00 18.20 0.00 2.19 33.77 0 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W C 13A4ocs 16D-30(d 0.143 0.032 my - 4.00 _ 0.00 2.19 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X30.(ld 0.408 - 1.18 0.79 16 16 19 13 40 40 47 32 F i 22A4ph 1.358 - 38.02 0.00 16 0 0 0 40 5 190 0 6 c)AED excursion -1 -12 Envelope loss/gain 19 12 608 508 12 a) Infiltration 0 0 108 31 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants rQ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 19 12 716 539 Less erdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistrihutbn -19 -12 339 350 14 Subtotal 0 0 1055 890 15 Duct loads 1NO 30% 0 0 16% 30% 172 267 Trial room bad 0 0 1227 1157 Air required(cfm) 0 0 47 52 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrlgtiioo'P!- 2020-Feb-17 08:35:03 RlghtSuite® Universal 2019 19.0.08 RSLI08101 Page 13 ...It WVACINOEL RESIDENCE WITH ICY AND SUNROOM.rup Cale =MJB Front Door feces: E wr ghtsoft' Right-M Worksheet Job: AHU 3 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name AHU 3 MASTER BEDROOM 2 Exposed wall 83.3 It 17.9 ft 3 Room height 10.7 R 12.0 It heaticool 4 Room dimensions 1.0 x 331.5 It 5 Room area 924.5 W 331.6 f' Ty Construction U-value Or HTM Area (82) Load Area (8.) Load number (Btuwft? *F) or perimeter 01) (Btuh) or perimeter (ft) (Btuh) Heal Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A4ccs 0.143 It4.00 2.19 40 40 160 88 0 0 0 0 2 glazing, cir ions 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 w 13AAccs 0.143 ne 4.00 2.19 42 35 139 76 0 0 0 0 L G 2 glazing. dr [arts 0.650 no 18.20 26.88 8 0 140 206 0 0 0 0 11 W 13A-4ms 0.143 a 4.00 2.19 170 15B 633 346 0 0 0 0 LG 2 glazing, dr lone 0.650 a 18.20 33.77 12 0 218 405 0 0 0 0 w 13A4ocs 0.143 se 4.00 2.19 92 85 339 185 0 0 0 0 L G 2 glazing, dr Iarre 0.650 se 18.20 27.05 8 0 140 207 0 0 0 0 w " 13A-4ccs 0.143 0.650 s 4.00 18.20 2.19 16.03 386 60 326 0 1305 1092 713 962 216 36 180 0 721 655 394 577 W 2 glazing, clr lore 13A4ccs 0.143 s sw 4.00 2.19 50 50 200 109 0 0 0 0 13A 4acs 0.143 w 4.00 2.19 90 90 360 197 0 0 0 0 T-1' 2 glazing, clr Icwe 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 w 13M10cs 0.143 my 0.00 0.00 0 0 0 0 0 0 0 0 C 16D-30td 0.032 - 0.00 1 0 0 0 0 0 0 0 0 C 100Md 0.408 - 1.18 0.79 925 925 1089 733 332 332 391 263 F t 22A-tph 1.3m - 38.02 0.00 925 83 3169 0 332 18 681 0 6 c)AED excursion 01 1 11 Envelope loss/gain 8985 4227 2448 1245 12 e) Infiltration 1882 540 467 134 b) Room ventilation 0 0 0 0 13 Idemal gams: Occupants @ 230 0 0 0 0 Appliances/other 5500 4000 Subtotal (lines 6 to 13) 1OB67 10267 2915 5379 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 1 50 33 14 Subtotal 10867 10267 2%5 5412 15 Duct loads 21% 31% 2272 3199 21% 37% 620 1686 Total room load 13140 13467 3585 7099 Air required (cfm) 597 597 163 315 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -FWwrrght9of!- 2020-Feb-17 08:35:03 ' - "--"' RlghtSuite@ UnWmai 2019 19.0.08 RSL108101 Page 14 ...ft FMACINOEL RESIDENCE WITH ICY AND SUNROOM.rup Calc = MJB Front Door laces: E wrightsoft- Right-J® Worksheet Job: AHU 3 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name M TOILET M BATH 2 Egxsed wall 0 ft 31.4 it 3 Room height 10.0 It hwVcwl 10.0 It heat/cool 4 Room ciimensions 6.0 x 4.0 it 1.0 x 275.0 ft 5 Room area 24.0 fF 275.0 ft- Ty Ty Construction U-value Or HTM Area (it) Load Area (8� Load number (Bluhlft"F) or perimeter JI) (6tuh) or perimeter 01) (Bluh) Heat Cool Gross WPB Heat Cool Gass WP/S Heat Cool 6 Vy I 13A-4ws 0.143 n 4.00 2.19 0 0 0 0 40 40 160 88 L-C 2gluing, cIr lowe 0.650 n. 0.00 0.00 0 0 0 0 0 0 0 0 w 13A4ocs 0.143 ne 4.00 2.19 0 0 0 0 42 35 139 76 I--G 2 olazina. clr lovv-e 0.650 no 18.20 26.88 0 0 0 0 8 0 140 205 11 W, 13A4ws 0.143 a 4.00 2.19 0 '0 0 0 100 88 352 193 LC 2 glazing, cIr lone 0.650 e. 18.20 33.77 0 0 0 0 12 0 218 405 13A4ws 0.143 as 4.00 2.19 0 0 0 0 42 35 139 76 T-G 2 glazing, cir lvh a 0.650 se 18.20 27.05 0 0 0 0 8 0 140 207 w r-C 13A-4ocs lose 0.143 0.650 s 4.00 18.20 2.19 16.03 0 0 0 0 0 0 0 0 90 0 90 0 360 0 197 0 IN 2glazing„clr 13A4ws 0.143 s sw 4.00 2.19 0 0 0 0 0 0 0 0 V�J 13A-4 cs _ 0.143 w 4.00 2.19 0 0 0 0 _ 0 0 0 0 L=C 2 glazing, cIr lave 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 av 0.00 0.00 0 0 0 0 0 0 0 0 C 16D-Md 0.032 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16x30Mal 0.405 - 1.18 0.79 24 24 28 19 275 275 324 218 F 22A-tph 1.358 - 36.02 0.00 24 0 0 0 275 31 1195 0 6 c)AED excursion S S1 Envelope bsstgain 26 12 3167 1634 12 a) Infiltration 0 0 681 195 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 500 300 Subtotal (fines 6 to 13) 28 512 3848 2130 Less exlemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 6 4 14 Subtotal 28 512 3854 2134 15 Ductlloeds 21% 31% 6 159 21% 31% 606 6% Total room load 34 6" 4659 2798 ir required(crm) Air. 2 30 212 124 Calculations approved byACCA to meet all requirements of Manual J ath Ed. v rman !M- 2020-Feb-17 08:35:03 RightSuheO Universal 2019 19.0.06 RSU08101 Page 15 ...R FMACINOEL RESIDENCE WITH ICY AND SUNROOM.rup Czlo = MJB Front Door faces: E F� wrightsoftRight-M) Worksheet Job: AHU 3 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-066-6799 Fax 772-466-6796 EmalI: QUICKCALCS@AOL.00M 1 Room name HIS WIC HER WIC 2 Egxsed wall 0 0 34.0 It 3 Roam height 10.0 It heat/cool 10.0 It heat/cool 4 Room dimensions 6.0 x 7.0 It 1.0 x 184.0 ft 5 Room area 42.0 fF 184.0 W Ty Construction U-value Or HTM Area (W) Load Area (II) Load number (BtuhtfP-°F) or pedmeter Qt) (Btuh) or perimeter (it) (BWh) Heal Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 W, 0.650 n 0 0 0 0 0 0 0 0 L-G 2 glazing, cirlwfe 2glazi13A-4g, 0.143 n 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-0as 0.143 rre 4.00 4.00 2.19 2.19 0 0 0 0 (1 0 D 0 " 2 olazing. clrlm-a 0.650 ne 18.20 26,88 0 0 0 0 0 0 0 0 11 W 13A-4ws 0.143 a 4.00 2.19 0 0 0 0 70 70 280 153 " 2 glazing, clr Iowa 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 W 13A4acs 0.143 se 4.00 2.19 0 0 0 0 50 50 200 109 L-G 2 glazing, dr lovre 0.650 se 1820 27.05 0 0 0 0 0 0 0 0 lAI 13A-4acs 0.143 s 4.00 2.19 0 0 0 0 80 56 224 123 LC 2 glazing, clr lows 0.650 s 18.20 16.03 0' 0 0 0 24 0 43T 385 W 13A4acs 0.143 sw 4.00 2.19 0 0 0 0 50 50 200 109 15� . 134-0ecs _ 0.143 w _ 4.00 2.19 0 0 0 0 90 90 360 197 I-C 2 glazing, cir 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 w 13A4ocs 0.143 rlw D.DD 0.00 0 0 0 0 0 0 0 0 C 16D-301d 0.032 - 0.00 0.00 0 a 0 0 0 _ 0 0 0 C 16X30-01d 0.408 - 1.18 0.79 42 42 49 33 164 184 217 146 F 22A4ph 1.358 - 39.02 0.00 42 0 0 0 184 34 1293 0 6 c)AEO excursion -8 36 Envelope loss/gain 49 26 3212 1258 12 a) Infiltration 0 0 735 211 b) Room ventilation 0 0 0 0 13 Internal gains: O=pants @ 230 0 0 0 0 Applances/other 50D 200 Subtotal (lines 6 to 13) 49 526 3947 1669 Less a Bernal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 24 16 0 0 14 Subtotal 74 542 3947 16M 15 Duct leads 21% 31% 15 169 21% 31% 825 520 Total room load 89 71t1 4772 2188 Air required (rim) 4 31 217 97 Calculations approved by ACCA to meet all requirements of Manual J Bth Ed. -q - ='Esn an- 2020-Feb-17 08:35:03 """' Right -Suite® Universal 2019 19.0.08 RSW8101 Page 16 ...it WAC%NOEL RESIDENCE WITH ICY AND SUNROOM.rup Calc = MJ8 Front Door Faces: E wrightsoft' Right-M Worksheet Job: AHU 3 Date: FEB. 17, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM i Room name AHU 3 CLST M HALL 2 6grosed wall 0 it 0 it 3 Room height 10.0 it heattewl 10.0 ft heaVood 4 Room dimensions 3.0 x 4.0 it 14.0 x 4.0 ft 5 Room area 12.0 fP 56.0 iP Ty Construction U-value Or HTM Area (8� Load Area (01) two number (iltuh/11 F) (&uwft-) or parameter (it) (8tuh) or perimeter QQ puh) Heal Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A-4acs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 T-G 2 glazing, dr lave _ 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 W 13A4acs 0.143 no 4.00 2.19 0 0 0 0 0 0 0 0 I----G 2 nlazina. dr 1. 0.650 ne 18.20 25.88 0 0 0 0 0 0 0 0 11 1?! 13AAcos 0.143 a 4.00 2.19 0 0' 0 0 0 0 0 0 -!' 2 glazing, dr laze 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 W L-G 13A ws 2 glazing, cir lave 0.143 0.650 as se 4.00 18.20 2.19 27.05 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1(�,r 13AAms 0.143 s, 4.00 2.19 _ 0 0 0 0 0 0 0 0 2 glazing, clr love 0.650 s 18.20 16.03 0 0 0 0 0 0 0 0 -10 W 13A-4ws 0.143 sw 4.00 2.19 0 0 0 0 0 0 0 0 14! 13A4ocs 0,143 w 4.00 2.19 0 0 0 0 0 0 _ 0 _ 0 t-G z glazing, cir to r 0.65o w 0.00 0.00 0 0 0 0 0 0 0 0 W 13A-4= 0.143 av 0.00 0.00 0 0 0 0 0 0 0 0 C 16D-30td 0.032 - 0.00 0.00 0 0 0 0 0 0 0 0 C 10 30-0td 0.408 - 1.18 0,79 12 12 14 10 56 56 65 44 F I I 1 22Atph 1.358 - 38.02 M00 12 0 0 0 56 0 0 0 6 c)AED euumion 0 -1 Envelope loss/gain 14 9 66 44 12 a) )ndihration 0 0 0 0 b) Roomventilation 0 0 0 0 13 Internal gams: Occupants (� 230 0 0 0 0 1 Appliancesrother 0 0 Subtotal (Goes 6 to 13) 14 9 66 44 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -14 -9 -66 -44 14 Subtotal 0 0 0 0 15 Dudloads 21% 31% 0 0 21% 31% 0 0 Tdallroom load 0 0 0 0 Air to Uimd(dm) 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wr�gtilpofC^ 2020-Feb-17 08:35:03 A&A - "-' Right-Sulte® Universal 2019 19.0.08 RSU08101 Page 17 ...it WAC\NOEL RESIDENCE WITH ICY AND SUNROOM.rup Cale - MJ8 Front Door faces: E wrightsotr Right-J® Worksheet Job: MINI SPLIT Date: FEB. 17, zozo By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772468-6799 Fax 772-466-6796 Email: OUCKCALCS(o)AOL.COM 1 Room name MINI SPLIT SUNROOM 2 3 Exposed wall Room height 52.9 it 13.0 it 52.9 it 130 8 heat7000l 4 Room dimensions 1.0 x 580.0 ft 5 Room area SW,o ft2 58f1.0 it - Ty Construction number U-value (BtuMt2. F) Or HTM Area (82) or permeter (it) Load (Btuh) Area (ft') or pedm filer (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross WKS Heat Cool 6 ILr 13Miocs 2 glazing, clr lave 13A4ccs 0.143 O.WO 0.143 In0.00 n ne 0.00 0.00 ' 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 11 I--G W, L-G W, f-- G 2 glazing, clr lone 13A-0ocs 2 glazing, clr lave 13A-4ws 2 glazing, clr love 13A-4acs 2 glazing, clr lowe 13A4acs 13A-0ocs 2 glazing, dr to a 0.650 0.143 0.650 0.143 0.650 0.143 0.650 0.143 cm 0.650 ne e a so se s s sw w w 0.00 - 0.00 O.W. 0.00 0.00 4.00 18.20 0.00 4.00 18.20 0.00 0.00 0.00 0.00 0.00 2.19 16.03 0.00 2.19 33.77 0 0 0 0 0 143 48 0 545 288 0 0 0 0 0 95 0 0 258 0 0 0 0 0 0 380 874 0 1033 5242 0 0 0- 0 0 208 769 0 - 564 9727 0 0 0 0 0 143 48 0 w258 288 - 0 0 0 0 0 95 0 0 0 0 0 0 0 0 380 . 874 0 1033 5242 0 0 0 0 0 208 769 0 564 9727 N/ a -1 w 4p1 -1 G w C 13A4= 16D30td 0.143 0.032 my - 0.00 0.90 0.00 0.96 0 580 0 580 0 Sm 0 557 0 580 0 580 0 520 0 557 C 16X30-Md 0.408 - 0.00 0.00 0 0 0 0 0 0 0 0 F 22A4ph 1.358 - 38.02 0.00 680 53 2012 0 6w 53 .2012 0 6 c)AED excursion 3918 3918 Envelope loss/gain 100W 15743 10060 15743 12 a) Infiltration 1489 427 1489 427 b) .Room ventilation 0 0 0 0 13 Internal gains: Ocwpands @ 230 0 0 0 0 Appliaooes/other 0 0 Subtotal (fines 6 to 13) 11550 161M 115w 161M Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 11550 16170 11550 16170 15 Duct loads 18% 10% 2113 1617 18% 10% 2113 1617 Totatroomload 13663 17787 13663 17787 Air required (cfm) 767 767 767 7S7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,c -pl- wrlghtsoft- 2020-Feb-1708:35:03 .� "' RightSulte® Universal 2019 19.0.08 RSW8101 Page 18 ...it FNAC\NOEL RESIDENCE WITH ICY AND SUNROOM.rup Calc = MJ8 Front Door faces: E �- wrightsoft° Duct System Summary Date: FEB. 17,2020 AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Emil: QUCKCALCS d(AOLCOM For. NOEL RESIDENCE, RAPHAELHENRI 12103 RIVERBEND ROAD, PORT ST WCIE, FL 34994 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 iN100ft 1550 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1550 cfm 241 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH c 669 3 29 1.000 5.0 0x0 VIFx 18.6 115.0 st3 13ATH3 h 1179 56 42 1.000 6.0 Ox0 VIFx 27.0 115.0 st4 BEDROOM c 2386 94 104 1.000 7.0 0x0 VIFx 10.5 115.0 st3 BEDROOM h 3192 152 123 1.000 7.0 OxO VIFx 19.7 115.0 st4 CABANA BATH c 1081 6 47 1.000 6.0 Ox 0 VIFx 65.8 175.0 st8 DINING ROOM h 4523 216 186 1.000 8.0 Ox0 VIFx 42.0 155.0 st7 FAMILY ROOM h 9432 450 173 1.000 8.0 Ox0 VIFx 22.3 115.0 st4 KITCHEN c 2838 28 123 1.000 7.0 Ox0 VIFx 40.5 155.0 st7 KITCHEN -A C 2838 28 123 1.000 7.0 Ox0 VIFx 15.0 115.0 st3 LAUNDRYROOM h 3788 181 65 1.000 6.0 Ox0 VIFx 26.4 135.0 Ste LIVING ROOM c 2240 27 97 1.000 7.0 Ox0 VIFx 63.8 175.0 st8 LIVIN3 ROOM -A c 2240 27 97 1.000 7.0 Ox0 VIFx 61.0 175.0 st8 OFFICE h 4980 238 189 1.000 8.0 Ox0 VIFx 66.0 175.0 st8 PANTRY c 689 5 30 1.000 5.0 0x0 VIFx 43.6 155.0 st7 PRAYER ROOM C 643 1 28 1.000 5.0 0x0 VIFx 23.4 135.0 Ste SINKS C 684 4 30 1.000 5.0 OxO VIFx 12.4 115.0 st3 WIC C 812 30 35 1.000 5.0 Ox0 VIFx 25.9 135.0 Ste WIC 3 c 657 2 29 1.000 5.0 Ox 0 VIFx 26.7 115.0 st4 y r- wrrghttsof - w+-r-.-, Rlgh[Sutte® Universal 2019 19.0.08 RSU08101 AWN ...ft FMAC1NOEL RESIDENCE WITH ICY AMID SUNROOM.rup Calc=MJ8 Front Door Faces: E 2020-Feb-17 08:35:16 Page 1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st8 Peak AVF 298 431 1.000 653 11.0 0 x 0 VlnlFlx st7 st7 Peak AVF 547 770 1.000 836 13.0 0 x 0 VinlFlx st6 st6 Peak AVF 759 898 1.000 840 14.0 0 x 0 VinlFlx st3 st3 Peak AVF 889 1184 1.000 848 16.0 0 x 0 VinlFlx st4 PeakAVF 661 366 1.000 1212 10.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb3 ox0 1550 1550 0 0 0 0 Ox 0 VIFx t Wrlght50ft- 2020-Feb•1708:35:16 �. �a•—. Right-Sultet Unlvemal 2019 19.0.08 RSL08101 Page 2 ...ft WAC1HOEL RESIDEMEWITH ICY AND SUNROOM.mp Celc=MJ8 Front Doorfaces: E wrightsofte Duct System Summary Date: FEB.17,2020 AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Email: QUCKCALCS@AOLCOM Project• • For. NOEL RESIDENCE, RAPHAELHENRI 12103 RIVERBEND ROAD, PORT ST LUCIE, FL 34984 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm 139 Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Mall Ln (ft) Ln (ft) Trunk GAME ROOM c 3970 170 178 1.000 8.0 Ox0 VIFx 24.4 115.0 st5 GAME ROOM -A c 3970 170 178 1.000 8.0 Ox0 VIFx 21.6 115.0 sty FALLF BATH c 1157 47 52 1.000 6.0 Ox0 VIFx 3.0 95.0 THEATRE h 2744 105 95 1.000 7.0 Ox0 VIFx 24.4 115.0 st5 THEATRE -A h 2744 105 95 1.000 7.0 ox0 VIFx 21.6 115.0 sty Name Trunk Type Htg (cfm) CIg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st5 Peak AVF 550 545 1.000 700 12.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (Cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mall Trunk rb2 0x0 597 597 0 0 0 0 Ox 0 VIFx t wrightsoft" .�.... RlghtSulte® Universal 2019 19.0.08 RSLID8101 ...It WAMNOEL RESIDENCE WITH ICY AND SUNROOM.rup Ceio - MJ8 Front Door noes: 2020-Feb-17 08:35:16 Page 3 + wrightsofte Duct System Summary AHU 3 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 77246"799 Fax 772-466-6796 Email: OUCKCALCS@AOLCOM For. NOEL RESIDENCE, RAPHAELHENRI 12103 RIVERBEND ROAD, PORT ST LLICIE, FL 34984 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm 129 Job: Date: FEB. 17, 2020 By: Cooling 1.OD in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk HER WIC h 4772 217 97 1.000 7.0 OxO VIFx 14.5 115.0 st1 HISWIC c 710 4 31 1.000 5.0 Ox0 VIFx 11.5 115.0 st1 M BATH IT 4659 212 124 1.000 7.0 OxO VIFx 11.5 115.0 st1 M TOILET c 671 2 30 1.000 5.0 Ox0 VIFx 9.2 115.0 st1 MASTER BEDROOM c 3549 81 157 1.000 8.0 Ox0 VIFx 10.5 115.0 st2 MASTER BEDROOM -A c 3549 81 157 1.000 8.0 Ox0 VIFx 9.5 115.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 163 315 1.000 712 9.0 0 x 0 VinlFlx st1 Peak AVF 434 282 1.000 983 9.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mail Trunk rb4 Ox 0 597 597 0 0 0 0 Ox 0 VIFx -F�- wrightsoft^ 2020-Feb-1708:05:16 a•• d•-,•-.,. Right-SLftet Unlwmal 2019 19.0.D8 RSW8101 Page 4 ...ft WAC\NOEL RESIDENCE WITH ICY AND SUNROOM.rop Colo - MJS Front Door faoes: E wrightsoft' Duct System Summary Date: FEB.17,2020 MINI SPLIT By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone 7724666799 Fax 772466-6796 Email: OWCKCALCS@AOLCOM Project Information For. NOEL RESIDENCE, RAPHAELHENRI 12103 RIVERBEND ROAD, PORT ST LLICIE, FL 34984 External static pressure Pressure losses Availablg static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 767 cfm Cooling 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in1100ft 767 cfm 0 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) I Trunk SUNRCOM c 17787 767 767 1 0 0 Ox0 VIFx 0 0 Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb5 Ox0 767 767 0 0 0 0 Ox 0 VIFx -F1'- wrightsoft' 2020-Feb-1708:35:16 • •••�•. ��•.-. RlghtSulte® Unhmmal 2019 19.0.08 RSLID6101 HI+l�P1 Page 5 ...ft HJAC\NOEL RESIDENCE WITH ICY AND SUNROOM. mp Celc = MJ6 Front Door laces: E 5� OFFICE USE ONLY: a DATE FILED: 61 ay 1 \ REVISION FEE: 5 • as PERMIT# 06 1 - dds -S5 RECEIPT# 1 Sa9Ol PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 �'�®�� (772) 462.1553 E APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION SC, NAJED LOCATION/SITEpy ADDRESS: ^ — n � _ ^ _ \ St. LUCI@ County CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME ADDRESS: ST. LUCIE CO CERT. #: CITY: STATE: PHONE (DAYTIME): - FAX: GYAW'" NAME: CITY: PHONE NAME: CITY: (11 PHONE(DA SLCCC: 9123109 Revised 06130117 INFORMATION: J� 79 . FAX: ZIP: ZIP: FILE COPY ENGINEER EVALUATE EVALUATION REPORT Polyglass USA, Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 (954)233-1230 =RECEIVED NEW I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 TEST CONSULT CERTIFY SCANNED Evaluation Report P12060.02.09-R24 BY FL5259-R28 1. Lucie County Date of Issuance: 02/24/2009 Revision 24: 01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable'rules and regulations governing the use of construction materials in the"State of Florida. The documentation submitted has been reviewed by Robert Nieminen; P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Root Underlayinents LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced .Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: _r Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 01/24/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOIetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc. is not owned, operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMOietc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING COMPONENT EVALUATION: 1. 2. 3. NNE:moletc. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3 / 1507.1.1 Physical Properties ASTM D226 2009 1507.2.4/ 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 REFERENCES: 91:103t Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PR101111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PR( (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076.02.01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083.02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14EBA 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99.1 02/08/2000 ERD (TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/23/2009 ERD (TST 6049) Wind Uplift P30540.11.09-Ri 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD (TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09.3 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD (TST 6049) Physical Properties P37300.10.11 10/19/2011 NEMO ETC, LLC. Evaluation Report P12060.02.09-R24 Certificate ofAuthorkatton #32455 67 EDITION (2017) FBC NON-HVHZ EVALUATION F1,5259-1128 Polyglass Roof Undertayments, (954) 233-1230 Revision 24: 01/24/2018 Page 2 of 14 4. ONEIMO etc. En2it Examination Reference Date ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties P40390.08,12-2 08/07/2012 ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD (TST 6049) Wind Uplift P3738.02.07-R2 04/29/2013 ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD (TST 6049) Wind Uplift P31751.05,03-R3 11/26/2013 ERD (TST 6049) Wind Uplift P11781.11.03-Ri 12/26/2013 ERD (TST 6049) Physical Properties P45270.05,14 05/12/2014 ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14.6 09/08/2014 ERD (TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD (TST 6049) Physical Properties P43290.10,14 10/17/2014 ERD (TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD (TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD (TST 6049) Physical Properties P44360.10.14-R1 05/18/2015 ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015 ERD (TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 ERD (TST 6049) Physical Properties PLYG-SCS080.07.16 07/16/2016 ERD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD (TST 6049) Physical Properties PLYG-SC33040.12.16 12/27/2016 ERD (TST 6049) Physical Properties PLYG-SC31900.03.17 03/10/2017 ERD (TST 6049) Physical Properties PLYG-SC32115.08.17 08/08/2017 ICC-ES(EVL 2396) IBC Compliance ESR-1697 11/01/2014 Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/L Affidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL, I.I.C. (QUA9625) Quality Control Service Confirmation Exp. 30/05/2018 PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlayments: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. 4.2 Self -Adhering Underlayments: 4.2.1 Polystick MTS or Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets FRSA/TRI April 2012. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, L-C. Evaluation Report P32060.02.09-R24 Certificate ofAuthor&atlon #32455 6" EDITION (2027) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018 Page 3 of 14 5. NNEMO I etc. 4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets FRSA/TRI April 2012. 4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012. 4.2.7 Polystick Dual Pro'" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970. 4.2.8 Polystick Tile ProT1' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 5.8). 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. 4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems. 4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems, LIMITATIONS: ' 5.1 This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ErC, U.C. Evaluation Report P12060.02.09-R24 [erNJ/cote of Authorization#32455 6EDITION(2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments, (954) 233.1230 Revision 24:01/24/2018 Page 4 of 14 ONEMOjetc. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Underlayment Asphah5hingles Nall -On The Foam -On Tile Metal Wood Shakes & Shingles Slate Elastobase Yes Yes (Base Sheet in 2-plysystem) Yes (Base Sheet In 2-ply system) Yes Yes Yes ElaStebaSeP Yes Yes n Base Sheet 22-plys system) Yes (Base Sheet in system) Yes Yes Yes Polyglass G2 Base No Yes (Base Sheet In 2-ply system) Yes (Base Sheet In 2-ply system) No No No Polyglass APP Base No Yes (Base Sheet in 2-plysystem) Yes (Base Sheet In 2-ply system) No No No Polystick MTS or MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TUP No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick TU Max No Yes Yes (See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Elastoflex GTU Yes Yes Yes (See 5.5.1) No Yes Yes Poo"G Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Yes Yes Yes (See 5.5.1) No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' ' Adhesive Florida Product Underlayments Approval DAP Foam Touch'n Seal StormBond Roof FL14506 j PolystickTU Plus, PolystickTU Max Tile Adhesive Dow TIIeBond'" FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® AH-160 FL6332 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® RTA-1 FL6276 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product ApprovalforOverturning Moment Resistance Performance. NEMO ETC, U.C. Evaluation Report P32060.02.09-1124 Certfflcote ofAuthorizatfun k32455 67 EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233.1230 Revision 24: 01/24/2018 Page 5 of 14 NNEMOletc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type 11, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime, or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECU ROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECU ROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval, For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: ➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. NEMO ETC, I.I.C. Evaluation Report P32060.02.09-1124 Certif/cate of Aothorhatlon#32455 e EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZS Polyglass Roof Underlayments; (954) 233-2230 Revision 24: 01/24/2018 Page 6 of 14 NNEMOletc. 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04- 12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design_ Pressure =-90 s : Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #2 Maximum Design Pressure=-97.5 psf: Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 orASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/." ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-Inch o.c. #3 Maximum Design Pressure =-105 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FRI, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch c.c. #4 Maximum Design Pressure = -135 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 orASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Joints: Min. 4-Inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #5 Maximum Design Pressure=-315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG300 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #6 Maximum Design Pressure = -622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG300 orASTM D41 Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #7 Maximum Design Pressure = -30.0 psf": Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: it ga, x 1.25-inch long 1-inch head diameter round metal cap nails Spacing: 6-Inch o.c. at the 3-Inch wide side laps and 6-Inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEMO ETC, LLC. Evaluation Report P12060.02.09-R24 Certy/cate of Authorization#32455 e EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revislon 24: 01/24/2018 Page 7 of 14 ONEMOletc. #8 Maximum Design Pressure =-37.5 psf*: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #9 Maximum Design Pressure = -37.5 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #10 Maximum Desien Pressure =-45 osf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type II felt Fasteners: 11 ga, x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c, at the 2-Inch wide side laps and 4-inch o.c, at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied In full mopping of hot asphalt. #11 Maximum Design Pressure =-45 psf*: Deck: Min.19/32-inch plywood to meet project requirementsto satisfaction of Authority Having Jurisdiction, Base Sheet: Two (2) layers ASTM 0226, Type II felt Fasteners: 11 ga. x 1.25-Inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin caps Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap:Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt. #12 Maximum Desien Pressure =-45 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied rap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #13 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c, at the 2-inch wide side laps and 12-inch o.c, at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #14 Maximum Design Pressure =-52.5 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c, at the 3-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEMO ETC, U.C. Evaluation Report P32060.02.09-1124 Certtf/cate of Author/zatlon#324S5 67 EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233.1230 Revision 24: 01/24/2018 Page 8 of 14 NNEMOletc. #15 Maximum Design Pressure =-52.5 Dsf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt ortorch-applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-Inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #16 Maximum Design Pressure =-60 osf: Deck: Min. 19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: 11 ga. x 1.25-Inch long x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #17 Maximum Design Pressure =-60 osf: Deck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG 012 Standard Roofgrip with CMG Flat Bottom Metal Plates Spacing: 12-inch o.c. at the 4-Inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #18 Maximum Design Pressure=-67.5 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment) Fasteners: 12 ga, x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tilt caps Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #19 Maximum Design Pressure =-75 osf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch-applidd underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 30-Inch o.c. at the 4-Inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #20 Maximum Design Pressure =-90 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied rap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #21 Maximum Design Pressure=-90 osf: Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied rap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with CMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-Inch o.c, at the 4-Inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #22 Maximum Design Pressure =-90 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-Inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt. NEMO ETC, LLC. Evaluation Report P32060.02.09-R24 Certificate of Authorization #32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 9 of 14 ONEMOletc. #23 Maximum Design Pressure =.90 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment) Fasteners: Dekfast N14 with Dekfast Hex plates, CMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-Inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-Inch o.c, at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #24 Maximum Design Pressure =-97.5 osf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-Inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #25 Maximum Design Pressure=-105 osf: Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-Inch o.c. at the 2-inch wide side laps and-6-Inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #26 Maximum Design Pressure=-112.5 nsf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-Inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertln caps Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-Inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS or Polystick MTS PLUS, self -adhered Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap:Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #27 Maximum Design Pressure =-120 nsf: Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: CMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or CMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-Inch wide side laps and 6-Inch o.c, at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied. #28 Maximum Design Pressure =-120 nsf: . Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 64nch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. 5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of-45 psf. NEMO ETC, U.C. Evaluation Report P12060.02.09-R24 Certiflcate of Authorizatlen#32455 e EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233.1230 Revision 24: 01/24/2018 Page 10 of 14 NNEMOjetc. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180-days after installation. Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and :seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. 5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-1211; When loading roof tiles on the underlayment in direct -deck the assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGELIMITATIONS FOR DIRER -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU Flat 10-tile stack 7:12 Lugged 8-tile stack (6 over 2) 6:12 Elastoflex S6 G or 56 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS or MTS PLUS Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 1 4:12 NEMO ETC, I.I.C. Evaluatlon Report 1312060.02.09-R24 CertUtcate of Aathorizatfon#32455 e EDITIO N (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233-2230 Revision 24: 01/24/2018 Page 11 of 14 ONEIMO I etc. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads, Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 j Elastobase, Elastobase P or Mule -Hide Nail Base: 6.3.1 Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual. 6.4 Polystick MTS, MTS PLUS, IR-Xe, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or MU-X or Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR): 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment in FBCTable 1507.1.1 for the type of prepared roof covering to be installed, 6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers: All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule-Hlide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule - Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area Para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed. All seal -lap seams (selvage laps) must bek� firmly rolled with a minimum 28 lb, hand MX roller to ensure full contact and adhesion.Jk For Dual Pro and Tile Pro, align the edge of J ,s the top sheet to the end of the glue pattern;,7i F (the sheet will overlap the fabric). View of Ovelap Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details NEMO ETC, LLC. Evaluation Report P1:2060.02.09-R24 Cert/flwte ofAutharhotlon #32455 61N EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233.1230 Revision 24: 01/24/2018 Page 12 of 14 NNEMO I etc. Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tile ADolications (not allowed forPolvstick Dual Pro- IR-Xe orPolvstick MU-X): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet:(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein, 6.4.4. Two (2) Ply Underlavment Systems: Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This Is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired, 6.5 Elastoflex G.TU; Elastoflex S6 G or Elastoflex S6 G FR: -� 6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2022 (04-22) beneath mechanically fastened tile roof systems or the Holt Asphalt applied "Cap Sheet". in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04.12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04.12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates noted in Section 5,6, Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6:6 Polyflex G or Polyflex G FR: 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the `Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3). NEMO ETC, LLC. Evaluation Report P12000.02.09-R24 Cert%Icote ofAuthorknHon k32455 67" EDITIO N (2017) F13C NON-HVHZ EVALUATI ON F1.5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 13 of 14 7 S. 9. NNEIMO I etc. 6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6, Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. 6.7 Tile Staainrt: 6.7.1 Tile shall be loaded and staged In a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail - boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours, BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the noted QA agency for Information on product locations covered for F.A.C. 61G20-3 CIA requirements. The following plants have qualified products under their respective physical properties specifications. Plant Specification Product(s) Fernley, NV Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick MU-X Hazleton, PA M-D 13-0004 Elastoflex G TU Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick IR-Xe ASTM D1970 & FRSA/TRI April 2012 Polystick TU Plus ASTM D1970 & FRSA/TRI April 2012 Polystick TU Max Tuscaloosa, AL ASTM D4601, Type II Polyglass G2 Base Winter Haven, FL ASTM D226(physicals) Elastobase, Elastobase P _ ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick MTS, Polystick MTS PLUS FRSA/TRI April 2012 Polystick TU P FRSA/TRI April 2012 Polyflex SAP, Polyflex SA P FR ASTM D1970 Polystick Dual Pro ASTM D1970 & FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex 56, Elastoflex S6 G FR ASTM D6222 Polyflex G, Polyflex G FR QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com NEMO ETC, LLC. Certificate of AuthorhuHon #32455 - END OF EVALUATION REPORT - 6P EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Roof Underlayments; (954) 233-1230 Evaluation Report P32060.02.09-R24 FL5259-R28 Revision 24:01/24/2018 Page 14 of 14 ®® BASF Technical Data ^Sheet We create chemistry ENERTITE® G LOW -DENSITY, OPEN-CE eneit6te- OponCcr Spmy Polyteolhane Foam m0ation DESCRIPTION: RECEIVED AUG 232019 Lucie County, ENERTITE G is a twocomponent low -density open'cell spray polyurethane foam system designed for use In residential construction and common commercial insulation applications. ENERTITE G is compatible with most common construction materials, but can only be processed with ELASTOSPRAYa 8000A Isocyanate. The benefits of ENERTITE G include: • Superior insulation • Non -fibrous • Sound control TYPICAL PROPERTIESI'): PROPERTY METHOD ENERTITE G Resin,• Specific Gravity @ 70•F ASTM D 1638 1.135 Viscosity @ 77•F (cps) Brookfield 350 Cured Foam, Density, core (per @ 4" lifts) ASTM D 1622 0.5 (nominal) Open Cell Content (%) ASTM D 6226 -90 Thermal Resistance (aged) R-value (ftq hr °F/Btu In)m ASTM C518 3.9 / in @ 1-in thick 3.7 / in @ 44n thick Response to Thermal and Humid Aging (% linear change) 158°F 197% RH / 168 him ASTM D 2126 <.2.0 Water Absorption (vol %) ASTM D 2842 - 40% Tensile Strength AS7M D 1623 5.9 psi Water Vapor Transmission — 3.5-in foam thickness Permeability (Penn inch) ASTM E 96 59 (Calculated) Permeance (Penn) ASTM E 96 16.9 Surface Burning Characteristics Flame Spread Indexla) ASTM E 84 5 25 Smoke Developed Index ASTM E 64 5 450 (1) These physical property values are typical for this material as applied at our development facility under controlled conditions. SPF performance and actual physical properties volt vary with differences in application (i.e. ambient conditions, process equipment and settings, material throughput etc). As a result these published properties should be used as guidelines solely for the purpose of evaluation. Physical property specifications should be determined from actual production material, The above data vas collected from samples prepared using equipment configurations pertinent to lab conditions. Parameters can be obtained upon request by calling 600-700-1712. (2) The data chart shone the R-volue of this Insulation. 'R- means resistance to heat fiow The higher the R-value, the greater the insulating prover. Compare insulation R-values before you buy. There are other factors to consider. The amount of insulation Wit depend upon the climate, the type and sae of your house, and the fuel use patterns and famly size. If you buy too much insulation it wil cost you more than what you will save on fuel. To achieve proper If -values, it is essential that this Insulation be Installed properly. (3) This numerical flame spread rating does not reflect hazards presented by this or any other material under actual fire conditions Polyurethane foam system should not be left exposed � SC7 ��.�•,� 4cieC�Uh.L DITIONAL TESTING. APPROVALS $ CERTIFICATIOM� • ASTM E 84 (Class 1) with Product Listing M(4) • NFPA 285 complying assemblies available • Film Resistant assemblies available • INTERTEK Code Compliance Research Report CCRR-1032 • Thickness is not limited when installed behind a code -prescribed thermal barter (per ICC-ES AC377) • Approved for certain Attic 8 Crawl Space installations with and without prescriptive ignition barriers per ICC-ES AC377, Appendix A1.2.2 and Appendix X • CRITICAL RADIANT FLUX (attic Insulation) PROPERTY METHOD FNERJ1E G Critical Radiant Flux, ASTM E970 0.26 W/cm' 44n foam thickness Critical Radiant Flux, ASTM E970 0.25 W/cm" 6-in foam thickness • AIR LEAKAGE PROPERTY METHOD ENERTITEG Air Leakage, ASTM E 283 <0.02 Us -ma 3.5-In foam thickness (Us•mq @ 75 Pa AP) • GREENGUARD and GREENGUARD Gold Certification for VOC emissions • Meets the requirements of CDPH Section 01350 for VOC emissions and formaldehyde • Mold resistant per ASTM C1338 — "Pass" rating (no growth) ADDITIONAL INFORMATION: Odor level of spray polyurethane foam Is dependent on proper application using the recommended processing parameters and proper ventilation. Caution - Failure to follow the application precautions, safety data sheet Information as well as accepted industry practices (www ripreypolyurethane.org) may result in unwanted foam physical properties and applications that may not provide the desired results. This also Includes unwanted health risks such as possible respiratory issues, sensitization or eye irritations such as blue haze for applicators and workers located in the area being, sprayed. A full understanding of the foam processing and all safety risks must be completed before spraying. Call our BASF spray foam team g you have questions 800-706-0712. Please contact your local Sales or Technical Representative for specific questions regarding ENERTITE G properties, approvals, or codifications. and must be protected by a minimum 16-minute thermal barrier or other codecomplimd material (4) ASTM E 84 is a test as allowed by applicable building rode(s) and Code Officials. Building Codes provide guidelines building code recognize` representing miNmYm requirements. Further Information is available at ivwvr.lecsafe.om. thickness In excess of fc Consult all Authorities Having Jurisdiction (AHJ) over an area for additional or specific IBC Section 2603. requirements prior to beglnning any project BASF Corporation 1703 Crosspoint Avenue Houston, TX 77054 (800) 706-0712 Revision Date: October 10, 2017 Hv✓w.spf.basf.com Page 1 of 2 SVRAY FOA' .��ITI,�, IFPA 285 is a evaluate foam 200681 2009 ENERTITE® G LOW -DENSITY OPEN -CELL INSULATION GENERAL INFORMATION: ENERTITE G is a spray polyurethane foam (SPF) system Intended for installation by qualified contractors trained In the processing and application of SPF systems, as well as the plural -component polyurethane dispensing equipment required to do so. Contractors and applicators must comply With all applicable and appropriate storage, handling, processing and safety guidelines. BASF technical service personnel should be consulted in all cases where application conditions are questionable. ENERTITE G has an estimated theoretical yield range of 17,000-21,000 board feet per set. Actual yield performance can be In excess of or below the referenced estimated theoretical range based on factors affecting density including, however, not limited to: multiple lifts, spray pass thickness, substrate texture, substrate temperature, overspray loss, windy conditions, altitude, container residue, equipment characteristics & temperatures, applicator technique, etc. For help estimating yield for this and other spray foams, please consult Spray Polyurethane Foam Alliance's SPFA-121 SPF Estimating Reference Guide, CAUTIONS AND RECOMMENDATIONS: ENERTITE G is designed for an application rate of 'Fe inch minimum to 6 inches maximum per pass. Once installed and material has cooled, it Is possible to add additional applications in order to increase the overall installed thickness of SPF. Thicker installations are allowed based on large scale testing. Please see ESR-3102 for additional information. This application procedure Is in compliance with the Spray Polyurethane Foam Alliance (SPFA). ENERTITE G is NOT designed for use as an EXTERIOR roofing system. BASF offers a separate line of products for exterior roofing applications. For more information, please contact your sales representative. Cold -storage structures such as coolers and freezers demand special design considerations with regard to thermal insulation and moisture -vapor drive. ENERTITE G should NOT be installed in these types of constructions unless the structure was designed by a design professional for speck use as cold storage. ENERTITE G Is designed for installation in most standard construction configurations using common materials such as wood and mod products, metal and concrete. ENERTITE G has performed successfully when sprayed onto wood substrates down to 40OF using special cold weather application techniques. For heat sink -materials such as metal or concrete, ENERTITE G can be sprayed onto substrates down to 50°F, using a gash pass method. BASF recommends the use of mock ups or sample spray before starting the full-scale project. This will provide an opportunity to see how all materials are Installed and evaluate their properties priorto proceeding. Climate A aide, B side, Hose Temp (Adjust in+/-5°increments) Proportioner set pressure (spraying pressure) Colder 1257-135`F 1150-1450 Psi (soo-12oo poll Warmer 105'F-125OF 1150-1450 psi (goo-12oo psi Foam plastic materials installed in yells or ceilings may present a fire hazard unless protected by an approved, fire-resistant thermal barrier with a finish rating of not less than 15 minutes as required by building codes. Rim joists/header areas, in accordance with the IRC and IBC, may not require additional protection. Foam plastic must also be protected against ignition by code prescribed or properly tested materials in attics and crawl spaces. See relevant Building Codes and www.icesafe.org for more information. In addition to reading and understanding the SDS, all contractors and applicators must use appropriate respiratory, skin and eye Personal Protective Equipment (PPE) when handling and processing polyurethane chemical systems. Personnel should review the following documents published by Spray Polyurethane Foam Alliance (SPFA): AX-171 Course 101-R Chapter 1: Health, Safety and Environmental Aspects of Spray Polyurethane: Foam and Coverings www.soravoolvurethane.om Also, the following document is available from the Center for the Polyurethanes Industries (CPI): Model Respiratory Protection Program for Compliance with the Occupational Safety and Health Administration's Respiratory Protection Program Standard 29 C.F.R. §1910.134 As with all SPF systems, improper application techniques should be avoided. Examples of improper application techniques Include, but are not limited to excessive thickness of SPF, off -ratio material and spraying into or under rising SPF. Potential results of improperly installed SPF include: dangerously high reaction temperatures that may result in fire and offensive odors that may or may not dissipate. Improperly installed SPF must be removed and replaced With properly Installed materials. LARGE MASSES of SPF should be removed to an outside safe area, cut into smaller pieces and allowed to cool before discarding Into an appropriate trash receptacle. All areas that are sprayed Incorrectly or result in A only material, B only material, improperly mixed or off ratio materials, too thick of an application or two quick of a thickness build up, are to be removed and replaced with properly processed spray foam. All cleaning solvents and others materials are to be captured and properly disposed of and not left at the Job site. SPF insulation is combustible. HigMnlensity, heat sources such as welding or cutting torches must not be used in contact with or In close proximity to ENERTITE G or any polyurethane foam. The insulation must not be used in areas that have a maximum service temperature greater than 180°F(82'C). SHELF LIFE AND STORAGE CONDITIONS: ENERTITE G has a shelf life of approximately Six (6) months from the date of manufacture when stored in original, unopened containers at 50-BO°F. As with all industrial chemicals, this material should be stored In a covered, secure location and never in direct sunlight. Storage temperatures above the recommended range will shorten shelf life. Storage temperatures above the recommended range may also result in elevated headspace pressure within packages. LIMITED WARRANTY INFORMATION — PLEASE READ CAREFULLY: The information herein is to assist customers in determining whether our products are suitable for their applications. Our products are only intended for sale to Industrial and commercial customers. Customer assumes full responsibility for quality control, testing and determination of suitability of products for its intended application or use. We warrant that our products will meet our written liquid component specifications. We make no other warranty of any kind, either express or Implied, by fact or law, Including any warranty of merchantability or fitness for a particular purpose. Our total liability and customers' exclusive remedy for all proven claims is replacement of nonconforming product and in no event shall we be liable for any other damages. While descriptions, designs, data and information contained herein are presented in good faith and believed to be accurate, they are provided for guidance only. Because many factors Trey affect processing er applImforduse, BASF recommends thatthe reader make tests to determine the suitability of a product for a particular purpose prior to use. No vverandes of any Wad, either expressed or Implled, Including varantles of merchantability or fitness for a particular purpose, are made regarding products described or designs, data or information set forth, or that the products, designs, date or intonation my be sued vdthout Infringing the intellectual property rights Mothers. In no code shall the descriptions, information, data or designs provided be considered a part M BASPs terms and conditions of sale. Fuller the descriptions, deslgns, data, and Information furnished by BASF hereunder are given gratis and BASF assumes no obligation or liability for the description, designs, data or information given or results obtained all such being given and accepted atthe madws risk Warning: These products can be used to prepare a variety M polyurethane products. Polyurethanes are organic materials and must be Revision Date: October 10, 201 7 considered combustible. Page 2 of 2 Ei BASF We create chemistry Safety Data Sheet ENERTITE G RESIN Revision date: 2017/10/12 Page: 1/12 Version:2.0 (30685345/SDS GEN UIS/EN) 1. Identification Product identifier used on the label ENERTITE G RESIN Recommended use of the chemical and restriction on use Recommended use`: polyurethane component; industrial chemicals Suitable for use in industrial sector: Polymers industry; chemical industry The "Recommended use" identified forthis product is provided solely to comply with a Federal requirement and is not pan of the seller's published specification. The termsof this Safety Data Sheet (SDS) do not create or Infer any warranty, express or implied, including by incorporation into or reference in the seller's sales agreement. Details of the supplier of the safety data sheet Company: BASF CORPORATION 100 Park Avenue Florham Park, NJ 07932, USA Telephone: +1 973 245-6000 Emergency telephone number CH EMTREC: 1-800-424-9300 BASF HOTLINE: 1-800-832-HELP (4357) Other means of identification Chemical family: resin Synonyms: Urethane System Resin Component 2. Hazards Identification According to Reaulation 2012 OSHA Hazard Communication Standard: 29 CFR Part 19110.1200 Classification of the product Skin CorrArrit. 1 B Skin corrosion/irritation Eye Dam./Irrit. 1 Serious eye damageleye irritation STOT RE 2 (oral) Specific target organ toxicity — repeated exposure Aquatic Acute 3 Hazardous to the aquatic environment - acute Aquatic Chronic 3 Hazardous to the aquatic environment - chronic Safety Data Sheet ENERTITE G RESIN Label elements Pictogram: o 0 Signal Word: Danger Hazard Statement: H373 H314 H402 H412 May cause damage to organs (Kidney) through prolonged or repeated exposure (oral). Causes severe skin burns and eye damage. Harmful to aquatic life. Harmful to aquatic life with long lasting effects. Precautionary Statements (Prevention) P280 Wear protective gloves/protective clothing/eye protection/face protection. P273 Avoid release to the environment. P260 Do not breathe dust/gas/mist/vapours. P264 Wash with plenty of water and soap thoroughly after handling. Precautionary Statements (Response): P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P310 Immediately call a POISON CENTER or doctor/physician. P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing. P301 + P330 + P331 IF SWALLOWED: rinse mouth. Do NOT induce vomiting. Precautionary Statements (Storage): P405 Store locked up. Precautionary Statements (Disposal): P501 Dispose of contents/container to hazardous or special waste collection point. Hazards not otherwise classified No specific dangers known, if the regulations/notes for storage and handling are considered 3. Composition / Information on Ingredients Accordina to Regulation 2012 OSHA Hazard Communication Standard: 29 CFR Part 19110.1200 CAS Number Weight % Chemical name 13674-84-5 >= 15.0 - < 20.0% tris(2-chloro-1-methylethyl)phosphate 127087-87-0 >= 5.0 - < 15.0% 4-Nonylphenol, branched, ethoxylated 2212-32-0 >= 5.0 - < 7.0% 2-((2-(dimethylamin o)ethyl)methylamino)ethanol 6711-48-4 >= 3.0 - < 5.0% N'-(3-(dimethylamino)propyl)-N,N-dimethylpropane-1,3- diamine 111.4M >= 1.0 - < 3.0% diethylene glycol Safety Data Sheet ENERTITE G RESIN Revision date : 2017/10/12 Page: 3/12 Version: 2.0 (30685345/SDS_GEN_US/EN) 83016-70-0 >= 1.0 - < 3.0% 2-((2-(2-(dimethyl amino)ethoxy)ethyl)methyl amino)ethanol 9046-10-0 >= 0.3 - < 1.0% alpha-(2-Aminomethylethyl)-omega-(2- aminomethylethoxy)- poly(oxy(methyl-1,2-ethanediyl)) 4. First -Aid Measures Description of first aid measures General advice: First aid personnel should pay attention to their own safety. If the patient is likely to become unconscious, place and transport in stable sideways position (recovery position). Immediately remove contaminated clothing. If inhaled: Keep patient calm, remove to fresh air, seek medical attention. Immediately administer a corticosteroid from a controlled/metered dose inhaler. If on skin: Immediately wash thoroughly with plenty of water, apply sterile dressings, consult a skin specialist. If in eyes: Immediately wash affected eyes for at least 15 minutes under running water with eyelids held open, consult an eye specialist. If swallowed: Do not induce vomiting. Immediately rinse mouth and then drink 200-300 ml of water, seek medical attention. Most important symptoms and effects, both acute and delayed Symptoms: The most important known symptoms and effects are described in the labelling (see section 2) and/or in section 11. Information on: diethylene glycol Symptoms: Overexposure may cause:, vomiting, coma, abdominal cramps, lethargy, nausea, diarrhea, headache Information on: tris(2-chloro-l-methylethyl)phosphate Symptoms: Overexposure may cause:, convulsions, depression, hypoxemia, tremors Hazards: No hazards anticipated. Indication of any immediate medical attention and special treatment needed Note to Physician Treatment: Treat according to symptoms (decontamination, vital functions), no known specific antidote. 5. Fire -Fighting Measures Extinguishing media Suitable extinguishing media: water spray, dry powder, carbon dioxide, foam Safety Data Sheet ENERTITE G RESIN 4/12 Special hazards arising from the substance or mixture Hazards during fire -fighting: No particular hazards known. Advice for fire-fighters Protective equipment for fire -fighting: Firefighters should be equipped with self-contained breathing apparatus and turn -out gear Further information: Dispose of fire debris and contaminated extinguishing water in accordance with official regulations. 6. Accidental release measures Further accidental release measures: High risk of slipping due to leakage/spillage of product. Personal precautions, protective equipment and emergency procedures Use personal protective clothing. Environmental precautions Do not empty Into drains. Do not discharge into the subsoil/soil. Methods and material for containment and cleaning up Spills should be contained, solidified, and placed in suitable containers for disposal. 7. Handling and Storage Precautions for safe handling Ensure thorough ventilation of stores and work areas. Protect against moisture. Protection against fire and explosion: No special precautions necessary. Conditions for safe storage, including any incompatibilities Segregate from foods and animal feeds. Segregate from acids. Segregate from oxidants Suitable materials for containers: Carbon steel (Iron), High density polyethylene (HDPE), Low density polyethylene (LDPE), Stainless steel 1.4301 (V2) Further information on storage conditions: Containers should be stored tightly sealed in a dry place. Storage stability: Storage temperature: 16 - 27 °C Protect against moisture. The stated storage temperature is noted for health and safety in the workplace. With regard to Quality, please refer to the product specific Technical Bulletin. 8. Exposure Controls/Personal Protection No occupational exposure limits known. Safety Data Sheet ENERTITE Revision date : 2C G RESIN Advice on system design: Provide local exhaust ventilation to control vapours/mists. Personal protective equipment Respiratory protection: Wear a NIOSH-certified (or equivalent) organic vapour/particulate respirator as needed. Hand protection: Chemical resistant protective gloves Eye protection: Wear face shield or tightly fitting safety goggles (chemical goggles) if splashing hazard exists. Body protection: Standard work clothes and shoes. General safety and hygiene measures: Avoid contact with skin. Handle in accordance with good industrial hygiene and safety practice. Wear protective clothing as necessary to prevent contact. Avoid inhalation of vapours/mists. Wash soiled clothing immediately. 9. Physical and Chemical Properties Form: liquid Odour: amine -like Odour threshold: No applicable information available. Colour: yellow pH value: 9.5 Melting point: 0.00 °C Boiling point: 100.00 °C Sublimation point: No applicable information available. Flash point: > 200.00 OF Flammability: not flammable Lower explosion limit: For liquids not relevant for classification and labelling. The lower explosion point may be 5 -15 °C ' below the flash point. Upper explosion limit: For liquids not relevant for classification and labelling. Autoignition: > 250 °C Vapour pressure: < 0.1 hPa (25 °C) Density: 1.0000 g/cm3 (20.00 °C) Relative density: No applicable information available. Vapour density: No applicable information available. Partitioning coefficient n- Unspecified octanol/water(log Pow): Self -ignition not self -igniting temperature: Thermal decomposition: No decomposition if stored and handled as prescribedlndicated. Viscosity, dynamic: 350.000 mpa.s ( 25.00 °C) Viscosity, kinematic: No applicable information available. (closed cup) Safety Data Sheet ENERTITE G RESIN Revision date: 2017/10/12 Page: 6/12 Version:2.0 (30685345/SDS GEN US/EN) Solubility in water: slightly soluble Solubility (quantitative): No applicable information available. Solubility (qualitative): No applicable information available. Evaporation rate: Value can be approximated from Henry's Law Constant orvapor pressure. Other Information: If necessary, information on other physical and chemical parameters is indicated in this section. 10. Stability and Reactivity Reactivity No hazardous reactions if stored and handled as prescribed/indicated. Corrosion to metals: No corrosive effect on metal. Oxidizing properties: Not an oxidizer. Chemical stability The product is stable if stored and handled as prescribed/indicated. Possibility of hazardous reactions No hazardous reactions if stored and handled as prescribed/indicated. Conditions to avoid Temperature: < 0 degrees Celsius Incompatible materials acids, oxidizing agents, isocyanates Hazardous decomposition products Decomposition products: Hazardous decomposition products: carbon monoxide, carbon dioxide, nitrogen oxide, hydrogen cyanide Thermal decomposition: No decomposition if stored and handled as prescribed/indicated. 11. Toxicological information Primary routes of exposure Routes of entry for solids and liquids are ingestion and inhalation, but may include eye or skin contact. Routes of entry for gases include inhalation and eye contact. Skin contact may be a route of entry for liquefied gases. Acute Toxicity/Effects Oral Type of value: ATE Value: 2,737 mg/kg Safety Data Sheet ENERTITE G RESIN Revision date : 2017/10112 Page: 7/12 Version: 2.0 (30685345/SDS_GEN_US/EN) Inhalation No applicable information available. Dermal No applicable information available. Assessment other acute effects Assessment of STOT single: Based on the available information there is no specific target organ toxicity to be expected after a single exposure. Origin of data: expertjudgement Irritation / corrosion Assessment of irritating effects: Corrosive! Damages skin and eyes. May cause severe damage to the eyes. Sensitization Assessment of sensitization: The chemical structure does not suggest a sensitizing effect. No applicable information available. Aspiration Hazard No aspiration hazard expected. Chronic Toxicity/Effects Repeated dose toxicity Assessment of repeated dose toxicity: Repeated exposure may affect certain organs. Genetic toxicity Assessment of mutagenicity: The chemical structure does not suggest a specific alert for such an effect. No applicable information available. Carcinogenicity Assessment of carcinogenicity: The chemical structure does not suggest a specific alert for such an effect. No applicable information available. Reoroductive toxicity Assessment of reproduction toxicity: The chemical structure does not suggest a specific alert for such an effect. No applicable information available. Teratoaenicity Assessment of teratogenicity: The chemical structure does not suggest a specific alert for such an effect. No applicable information available. Other Information The product has not been tested. The statement has been derived from the properties of the individual components. Symptoms of Exposure The most important known symptoms and effects are described in the labelling (see section 2) and/or in section 11. Medical conditions aggravated by overexposure Data available do not indicate that there are medical conditions that are generally recognized as being aggravated by exposure to this substance/product. Safety Data Sheet ENERTITE G RESIN Revision date : 2017/10/12 Page: 8/12 Version:2.0 (30685345/SDS GEN US/EN) 12. Ecological Information Toxicity Aquatic toxicity Assessment of aquatic toxicity: Acutely harmful for aquatic organisms. Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment. The product has not been tested. The statement has been derived from the properties of the hydrolysis products. Toxicitv to fish Information on: alpha-(2-Aminomethylethyl)-omega-(2-aminomethylethoxy)- poly(oxy(methyl-1,2- ethanediyl)) LC50 (96 h) > 15 mg/l, Oncorhynchus mykiss (OECD Guideline 203, semistatic) The details of the toxic effect relate to the nominal concentration. Limit concentration test only (LIMIT test). LC50 (96 h) 772.14 mgA, Cyprinodon variegatus (OECD Guideline 203, static) The details of the toxic effect relate to the nominal concentration. Information on: Brominated aromatic diol LC50 (96 h) 12 mgA, Lepomis macrochirus (other) Information on: 2-Propanol, 1-chloro-, phosphate (3:1) LC50 (96 h) 51 mgA, Pimephales promelas (Fish test acute, static) LC50 (96 h) 56 mgA, Brachydanio redo (Fish test acute, static) Information on: N-(3-(dimethylamino)propyl)-N,N-dimethylpropane-1,3-diamine LC50 (96 h) > 21.5 - < 46.4 mgA, Brachydanio rerio (OECD 203; ISO 7346; 84/449/EEC, C.1, static) The statement of the toxic effect relates to the analytically determined concentration. The product will cause changes in the pH value of the test system. The result refers to an unneutralized sample. After neutralization no appreciable reduction in harmful effect can be observed. Aquatic invertebrates Information on: alpha-(2-Aminomethylethyl)-omega-(2-aminomethylethoxy)- poly(oxy(methyl-1,2- ethanedlyl)) EC50 (48 h) 80 mgA, Daphnia magna (OECD Guideline 202, part 1, static) The details of the toxic effect relate to the nominal concentration. EC50 (48 h) 418.34 mg/l, Arcatia tonsa (Daphnia test acute, static) The details of the toxic effect relate to the nominal concentration. Information on: 2-Propanol, 1-chloro-, phosphate (3:1) EC50 (48 h) 131 mg/1, Daphnia magna Information on: N' (3-(dimethylamino)propyl)-N,N-dimethylpropane-1,3-diamine EC50 (46 h) 24 mg/l, Daphnia magna (OECD Guideline 202, part 1, Flow through.) The statement of the toxic effect relates to the analytically determined concentration Acuatic plants Information on: alpha-(2-Aminomethylethyl)-omega7(2-aminomethylethoxy)- poly(oxy(methyl-f,2r ethanedlyl)) Safety Data Sheet ENERTITE G RESIN Revision date : 2017/10112 Page: 9/12 Version: 2 0 (30685345/SDS_GEN_MEN) EC50 (72 h) 15 mg/I (growth rate), Pseudokirchneriella subcapitata (OECD Guideline 201, static) The details of the toxic effect relate to the nominal concentration. EC10 (72 h) 1.4 mg/1(growth rate), Pseudokirchneriella subcapitata (OECD Guideline 201, static) The details of the toxic effect relate to the nominal concentration. EC50 (72 h) 141.72 mg/l, Skeletonema costatum (ISO/DIS 10253, static) The details of the toxic effect relate to the nominal concentration. No observed effect concentration (72 h) 100 mg/l, Skeletonema costatum (ISO/DIS 10253, static) The details of the toxic effect relate to the nominal concentration., Information on: N'-(3-(dimethylamino)propyl)-N,N-dimethylpropane-1,3-diamine EC50 (72 h) 7.9 mg/I (biomass), algae (OECD Guideline 201, static) No observed effect concentration (72 h) 1.2 mgA (biomass), algae (OECD Guideline 201, static) Lowest observed effect concentration (72 h) 1.7 mg/I (biomass), algae (OECD Guideline 201, static) Information on: 2-Propanol, 1-chloro-, phosphate (3:1) EC50 (72 h) 82 mg1I (growth rate), Pseudokirchneriella subcapitata (OECD Guideline 201, static) Nominal concentration. Chronic toxicity to aquatic invertebrates Information on: N'-(3-(dimethylamino)propyl)-N,N-dimethylpropane-1,3-diamine No observed effect concentration (96 h) 3.5 mgA, Daphnia sp. Information on: alpha-(2-Aminomethylethyl)-omega-(2-aminomethylethoxy)- poly(oxy(methyl-1,2- ethanediyl)) No data available regarding toxicity to daphnids. Information on: 2-Propanol, 1-chloro-, phosphate (3:1) No observed effect concentration (21 d) 32 mg/I, Daphnia magna (OECD Guideline 202, part 2, semistatic) Nominal concentration. Microorganisms/Effect on activated sludge Toxicity to microorganisms Information on: N'-(3-(dimethylamino)propyl)-N,N-dimethylpropane-1,3-diamine activated sludge/EC20 (3 h): 170 mg/1 OECD Guideline 209 static activated sludge/No observed effect concentration (3 h): 1,000 mg/l OECD Guideline 209 static activated sludge/EC50 (3 h): > 1,000 mgA Information on: alpha-(2-Aminomethylethyl)-omega-(2-aminomethylethoxy)- poly(oxy(methyl-1,2- ethanediyl)) OECD Guideline 209 aerobic activated sludge of a predominantly domestic sewage/EC20 (3 h): 380 mgA The details of the toxic effect relate to the nominal concentration. Information on: 2-Propanol, 1-chloro-, phosphate (3:1) Persistence and degradability Assessment biodearadation and elimination (1-120) Poorly biodegradable. Safety Data Sheet ENERTITE G RESIN Revision date: 2017/10/12 Elimination information Poorly biodegradable. Bioaccumulative potential Assessment bioaccumulatlon-potential Does not significantly accumulate In organisms. Mobility in soil Assessment transport between environmental compartments Adsorption to solid soil phase is not expected. Additional information Adsorbable organically -bound halogen (AOX): This product contains no organically -bound halogen. Other ecotoxicological advice: The product has not been tested'. Do not discharge product into the environment without control. 13. Disposal considerations Waste disposal of substance: Incinerate in a licensed facility. Dispose of in a licensed facility. Do not discharge substance/product into sewer system. Container disposal: Steel drums must be emptied and can be sent to a licensed drum reconditioner for reuse, a scrap metal dealer or an approved landfill. Do not attempt to refill or clean containers since residue is difficult to remove. Under no circumstances should empty drums be burned or cut open with gas or electric torch as toxic decomposition products may be liberated. Do not reuse empty containers. 14. Transport Information Land transport USDOT Hazard class: 8 Packing group: III ID number: UN 1760 Hazard label: 8 Proper shipping name: CORROSIVE LIQUID, N.O.S. (contains N-[3- (D I METHYLAM I NO)PROPYL]-N, N-D IMETHYLPROPAN E-1, 3- DIAMINE) Sea transport IMDG Hazard class: 8 Packing group: III ID number: UN 1760 Hazard label: 8 Marine pollutant: NO Proper shipping name: CORROSIVE LIQUID, N.O.S. (contains N-[3- Safety Data Sheet ENERTITE G RESIN Revision date : 2017/10112 Page: 11/12 Version: 2.0 (30685345/SDS_GEN_US/EN) (D IMETHYLAM I N O)PROPYL]-N, N-D I METHYLP ROPAN E-1, 3- DIAMINE) Air transport IATA/ICAO Hazard class: 8 Packing group: III ID number: UN 1760 Hazard label: 8 Proper shipping name: CORROSIVE LIQUID, N.O.S. (contains N-[3- (D I METHYLAM IN O)P ROPYL]-N, N-DI METHYLP ROPANE-1, 3- DIAMINE) 15. Regulatory Information Federal Regulations Registration status: Chemical TSCA, US released / listed EPCRA 311/312 (Hazard categories): Refer to SIDS section 2 for GHS hazard classes applicable for this product. State reaulations State RTK CAS Number Chemical name PA 11146-6 diethylene glycol Safe Drinking Water & Toxic Enforcement Act, CA Prop. 65: WARNING: This product can expose you to chemicals including PROPYLENE OXIDE, which is known to the State of California to cause cancer, and TOLUENE, which is known to the State of California to cause birth defects or other reproductive harm. For more information, go to www.P65Warnings,ca.gov. [Other Prop 65 components may be present in the product.] NFPA Hazard codes: Health:3 Fire: 1 Reactivity: 1 Special: HMIS III rating Health: 3a Flammability: 1 Physical hazard:1 16. Other Information SIDS Prepared by: BASF NA Product Regulations BIDS Prepared on: 2017/10/12 We support worldwide Responsible Care® initiatives. We value the health and safety of our employees, customers, suppliers and neighbors, and the protection of the environment. Our commitment to Responsible Care is integral to conducting our business and operating our facilities in Safety Data Sheet ENERTITE G RESIN a safe and environmentally responsible fashion, supporting our customers and suppliers in ensuring the safe and environmentally sound handling of our products, and minimizing the impact of our operations on society and the environment during production, storage, transport, use and disposal of our products. IMPORTANT: WHILE THE DESCRIPTIONS, DESIGNS, DATA AND INFORMATION CONTAINED HEREIN ARE PRESENTED IN GOOD FAITH AND BELIEVED TO BE ACCURATE, IT IS PROVIDED FOR YOUR GUIDANCE ONLY. BECAUSE MANY FACTORS MAY AFFECT PROCESSING OR APPLICATION/USE, WE RECOMMEND THAT YOU MAKE TESTS TO DETERMINE THE SUITABILITY OF A PRODUCT FOR YOUR PARTICULAR PURPOSE PRIOR TO USE. NO WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE MADE REGARDING PRODUCTS DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH, OR THAT THE PRODUCTS, DESIGNS, DATA OR INFORMATION MAY BE USED WITHOUT INFRINGING THE INTELLECTUAL PROPERTY RIGHTS OF OTHERS. IN NO CASE SHALL THE DESCRIPTIONS, INFORMATION, DATA OR DESIGNS PROVIDED BE CONSIDERED A PART OF OUR TERMS AND CONDITIONS OF SALE. FURTHER, YOU EXPRESSLY UNDERSTAND AND AGREE THAT THE DESCRIPTIONS, DESIGNS, DATA, AND INFORMATION FURNISHED BY OUR COMPANY HEREUNDER ARE GIVEN GRATIS AND WE ASSUME NO OBLIGATION OR LIABILITY FOR THE DESCRIPTION, DESIGNS, DATA AND INFORMATION GIVEN OR RESULTS OBTAINED, ALL SUCH BEING GIVEN AND ACCEPTED AT YOUR RISK. BASF CORPORATION WILL NOT MAKE ITS PRODUCTS AVAILABLE TO CUSTOMERS FOR USE IN THE MANUFACTURE OF MEDICAL DEVICES WHICH ARE INTENDED FOR PERMANENT IMPLANTATION IN THE HUMAN BODY OR IN PERMANENT CONTACT WITH INTERNAL BODILY TISSUES OR FLUIDS. END OF DATA SHEET i . - ENERTffE° G Open -cell Spray Polyurethane Foam insulation ENERTITE® G is a low -density open -cell spray polyurethane foam (SPF) insulation, formulated to meet GREENGUARD Gold standards. This means stricter criteria including safety for sensitive individuals (such as children and the elderly) and ensures the product is acceptable for use in school and healthcare facilities. By using our spray foam insulation technology that expands in place to fills gaps and spaces, you can create a better indoor air environment while reducing energy costs. Why Choose ENERTITE® G? • GREENGUARD Gold certification • Low-VOC, low environmental impact • R-value of 3.7 - 3.9 per inch • Improve Indoor air quality • Save energy and improve comfort • Create a more airtight, quiet building 1-888-900-FOAM BASF Corporation 1703 Crosspoint Avenue Houston, TX 77054 Fax:713-383-4592 www.spf.basf.com spfinfoObasf.com 1703-GOLDHOME Applications: • Homes • Schools • Hospitals • Office buildings • Multi -family housing • Lodging THEY ARE PROVIDED FOR OUCANCE ONLY. BECAUSE MANY FACTORS MAY AFFECT PROCESSING OR APPLICAMOWUSE, BASF RECOMMENDS THAT THE READER MAKE TESTS TO DETERMINE THE SUITABILITY OF PRODUCT FOR A PARTIOUWi PURPOSE PRIOR TO USE. NO WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILRY OR FITNESS FOR A FARTICUTAR PURPOSE, ARE MADE REGARDING PRODUCTS DESCRIBED OR DESIGNS, DATA OR INFORMATION SET FORTH, OR THATTHE PRODUCTS, DESIGNS, DATA OR INFORMATION MAY BE USED WITHOUT INFRINGING THE INTELLECTUAL PROPERTY RIGHTS OF OTHERS. IN NO CASE SHALL THE DESCRIPTIONS. INFORMATION. DATA OR DESIGNS PROVIDED BE CONSIDERED APART OF THE BASF TERMS AND CONDITIONS OF DL en• the UL 10905 are tr dtehsfne of UL U C. ENERTITL Is a reE sseted tradshesk 0 BASF Corporation. 0 2018 BASF C.Whttlon We create chemistry ATTENTION — THIS SIGN SHALL NOT BE REMOVED. Caution: This is an unvented attic by design. • No modification may be made to this unvented condition. • The attic shall not be vented. • Holes into the unvented attic shall be immediately repaired and sealed. • Penetrations of the ceiling or wall membrane between the unventeld attic and living space, other than the code required attic access, must be protected in an approved manner. • This unvented attic shall not be used for storage. See Intertek Code Compliance Research Report CCRR-1032 for more details. Additional Limitations of Use per CCRR-1032: • Entry to the attic is only to service utilities and no storage is permitted. • There are no interconnected attic areas. • Air, in the attic is not circulated to other parts of the building. • Combustion air is provided in accordance with IMC (International Mechanical Code) Section 701 [Sections 701 and 703]. If any of these limitations are not met, follow ICC R316 code requirements for thermal or ignition barrier fire protection. Call BASF Technical Applications for any additional guidance, 800-706-071Z ext. 2 t1 Y1D E6ertite G (NEW PRODUCT) N (' L j f r I J ioo866-420 Certificate Number 09/25/2017- 08(i5/2os8 Certificate Period Certified Status UL 2818 - 2oi3 Gold Standard for Chemical Emissions for Building Materials, Finishes and Furnishings Wall finishes are determined compliant in accordance with California Department of Public Health (CDPH) Standard Method Vi.2-2017 using an Office Environment with an air change ofo.68 hr L and a loading of33.4o mT. Product tested in accordance with UL 2821 test method to show compliance to emission limits on UL 2818. Section 7.1 and 7.2. Environment UL FnvironmentinvestigaMtrepresmta[ive somples of the ider edProdecrysJto dvideatTed Standard(s)orotherropEnanentz m acmrdame with theagreemeM and any applim64 Program s Ice terms in piace benvern UL Fnmmonnentandthe Corbf to Holder(caUedively Agreement -- The Certykate Holderisaudwouedto osethe UL FwranmentMarkfortheident)iedP docgs)monufa mdathepraduabn sWs)mvendbytheLcETestRgoM in accordance wdhthetemu oftheAgremieat This Cereficavb wlidfmthel&nbfieddetesonLe themisnon�mpho wah GREENGUARD Gold Certification Criteria for Building Products and Interior Finishes Criteria i CAS Number Maximum Allowable Predicted Concentration Units TVOC(A) 0.22 mg/m3 { Formaldehyde ! 50-00-0 ¢ _ 9 (7.3 ppb) µgJm3 Total Aldehydes (a) f 0.043 ( PPm 4-Phenylcyclohexene 4994-i6-5 6.5 I µg/m3 I Particle Matter less than to µm (c) 20 119/m3 i-Methyl-2-pyrrolidinone(o) f 872-50-4 16o µg/m3 1 Individual VOCs (E) i' i ! 1/2 CREL or 1/loothTLV (A) Defined to be the total response of measured VOCs falling within the Cs —Ctb range, with responses calibrated to a toluene surrogate. Maximum allowable predicted TVOC concentrations for GREENGUARD Gold (0.22 mg/m3) fall in the range of0.5 mg/m3 or less, as specified in CDPH Standard Method v1.1. (e) The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLCJUV analysis. (O Particle emission requirement only applicable to HVAC Duct Products with exposed surface area in air streams (a forced air test with specific test method) and for wood finishing (sanding) systems. (o> Based on the CA Prop 65 Maximum Allowable Dose Level for inhalation of 3,200 jig/day and an inhalation rate of 20 m3/day (E> Allowable levels for chemicals not listed are derived from the lower of 1/2 the California Office of Environmental Health Hazard Assessment (OEHHA) Chronic Reference Exposure Level (CREL) as required per the CDPH/EHLB/Standard Method v1.1 and BIFMA level credit 7.6.2 and 1/100th of the Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 GIenway, Building D-7, and Cincinnati, OH 45211-4438). M Environment UL EnNmnmentinvestigatedaaresmtaaesamples oftheidentWProdua(s)tothe afennfidStaxf.*()arothermyairemernz inacrordarce withthe agreements and any appbmbleprogm sevae rears in platy between UL E wmnmeat andthe C.Mficatz Hdder(maecb'vely•Agreeacent7. the Cergfmte Holdefisauthorizedtoase the UL Ermmn Markfortheidenhfied Prodixi(s)manufac dattheprodaaion Wi )roveredbythe UIXTs Repart, in acrordwn with the tmmaftheAgreemat AesCenifiwte6 vob'dfarHeiderrofieddatesanlessthereisnOn Ptla ewdh I F. fir ®G,t�` iL" , r(Uj _AXVk1bW0_�161V§§ �f J Residential attics can be designed and constructed to be either vented or unvented in any hygro- thermal zone. Either method is utilized to address or control ice dams, moisture accumulation and heat gain. From BASF Tech Tip # 5, we find that in non -vented cathedral or attic spaces insulated with Enertite®, the open -cell spray foam eliminates the need to insulate ductwork and piping, creates a conditioned space In which the HVAC equipment will operate more efficiently, and effectively eliminates'hot and'cold spots. It is important for Builders, Designers and Contractors to understand Ignition and Thermal Barrier requirements per local Code when using foam plastics in residential attic applications. The 2015 International Residential Code (IRC R316.4 "Thermal barrier") requires that "foam plastic shall be separated from the interior of a building by an approved thermal barrier of not less than 1/2-inch (12.7 mm) gypsum wallboard, 23/32-inch' (18.2 mm) wood structural panel or a material that is tested idaccordance with and meets the acceptance criteria of both the Temperature Transmission Fire Test and the Integrity Fire Test of NFPA 275." Some attics or crawl spaces will qualify (per R316.5.3) to allow for foam plastics without -the use of a thermal barriers, when the space is entered only for purposes of repair or maintenance (i.e. no storage), where the foam is protected against ignition using one of the listed prescriptive ignition barrier (IB) materials. Allowing for further flexibility, the IRC created an exemption in section R316,6 "Specific approval', which states "Foam plastic not meeting the requirements of Sections R315.3 through R316.5 shall be specifically approved based on one of the following approved tests: NFPA 286 with the acceptance criteria cf Section R302.9.4, FM 4880, UL 1040 or UL 1715, orfire tests related to actual end -use configurations." Leveraging this alternative. BASF conducted end -use configuration testing allowing designers. builders or contractors the option to eliminate the prescribed ignition barrier when using the Enertite° open -cell foam system as part: of an Unvented Attic Assembly as indicated in Intertek Code Compliance Research Report CCRII-1032 BASF has conducted end use configuration testing (per IRC Section 316.6 and IBC 2603.9) and analysis to qualify the use of BASF Enertite® NM and Enertite® G series insulations without a prescriptive ignition barrier or intumescent coating in unvented attics conforming with 21315 IRC Section R806.5 [806.4 in 2012) and R316.5.3 as described above. The BASF Enertite® insulations may be installed perthe details of CCRR-1032, without the prescriptive ignition barrier, when the following requirements are met: Rev. 5/2018 BASF corporation- Inside Technical Sales 1703 Crosspoint Avenue Houston, TX 77054 Tel: (Toll Free) 800-706-0712—Option 2 (Direct) 713383-4513 vmv.spf.basf.com Page 2 r Tech Tip # 25 a) Entry to the attic or crawl space is only for the service of utilities and no storage is permitted) b) There are no interconnected attic or crawl space areas c) Air in the attic or crawl space is not circulated to other parts of the building d) Attic ventilation is provided when required by IRC section R806 / IBC Section 1203.2 (Except: Enertite Series insulation is an air impermeable insulation and thus permitted in unvented attics in accordance with 2015 IRC Section R806.5 / 2015 IBC Section 1203.3) e) Combustion air is provided in.accordance with International Mechanical Code section 701 The design requirements when using Enertite NM or Enertite® G in Unvented Attics without th'e: prescribed ignition barriers (or alternative IB coatings) include the following: 1- Minimum thickness of 3.5",Enertite over the roof deck and wall surfaces. 2- Maximum thickness of 16" on the underside of roof sheathing oron vertical wall surfaces. 3- Rafters may be left without foam coverage, or may be covered with foam up to the maximum thickness. 4- Attic access complying with IRC Section 807 must,be installed. This access may be either an outward opening access (toward the living space) horizontally placed in the attic floor, OR a Rockfon Pacific ceiling tile asthe access panel (in lieu of -gypsum board or an outward) opening hatch access). This Rockfon ceiling panel pop-up access, or outward opening access may be red ucedl to a minimum 19" x 19" size, as long as there is another code -compliant sized attic access installed. 5- Items penetrating the roof deck or walls, such as skylight wells or vents, must be covered) with a minimum of 1.5" of Enertite° insulation. . 6- Signage shall be permanently affixed in the attic and shall be visible from all points within the attic. For further details, reference CCRR-1032 and your respective local code requirements. Follow all) local codes and secure professional design expertise when deciding on materials and methods., Any technical advice furnished or recommendation made by the authors concerning any use or application of anyproduct is believed to be reliable,. but the authors make no warranty, either express or Implied, as to Its accuracy or completeness or of the results to be obtained. With regard to any handling of any IIASFproduct the end user assumes full responsibilityfor quality control, testing and determination of suitability of product for its intended application or use. For any additional information about BASF spray foam systems, please visit www.spf.basf.com To speak with a technical sales representative, please call 800-706-0712 x2. BASF corporation. Inside Technical Sales 1703 Crosspoint Avenue Houston, TX 77054 Tel: (roll Free) 800-706-0712 — Option 2 (Direct) 713.383-4513 vmw.spf.basf.com Rev. 5/2018 r 9 u BASF We create chemistry Wednesday, December 20, 2017 To Whom It May Concern: Enertite® NM and Enertite® G open -cell foam systems have been approved for use without an ignition barrier in residential attic applications. BASF is proud to introduce this revised unvented attic insulation assembly to our current offerings, now including an alternative attic access. The unvented attic assembly was approved following comprehensive research and close consultation with Intertek to ensure all testing met the high safety standards required by Intertek. Code Compliance Research Report 1032 (CCRR-1032) for the BASF Enertite® Series has been edited with the following approval language (emphasis added): 4.4.2.2 Unvented Attics, BASF has conducted end use configuration testing (per IRC Section 316.6 and IBC 2603.9) and analysis to qualify the use of BASF Enertite® NM and Enertite® G insulations without a prescriptive ignition barrier or intumescent coating in unvented attics conforming with 2015 IRC Section R806.5 [806.4] and 2015 IBC 1203.3 (Note that unvented attics were not addressed the 2012 or earlier versions of the IBC). The testing and analysis is described in Priest & Associates EEV 10419 Revision 1, dated December 20, 2016. The conclusions of that evaluation are as follows: When Enertite® NM or Enertite G® are applied in unvented attics conforming to IRC Section R806.5 [2009 - R806.4], the insulation may be applied to the underside of roof sheathing and/orrafers, and to vertical surfaces to a minimum thickness of 3.5 inches (88.9 mm). Rafters may be left without foam coverage or may be covered with foam up to the maximum thickness allowed. Maximum thickness on the underside of roof sheathing or on vertical wall surfaces is 16 inches. The insulations may be left exposed to the attic without a prescriptive ignition barrier or an intumescent coating. The attic must have attic access complying with IRC Section 807, horizontally placed in the attic floor and opening outward toward the living space. For items penetrating the roof deck or walls, such as skylight wells or vents, the penetrating item exposed to the attic must be covered with a minimum of 1.5 inches of Enertite® NM or Enertite® G insulation. Unvented attics compliant with this design are required to be identified with signage as per CCRR-1032 Section 5.6.2, to be placed in the attic and to be visible from all points in the attic. See enclosed copy of the BASF sign that is available to you. See additional limitations and conditions of use in CCRR-1032. Alternative attic access has also been approved by Priest & Associates (EEV 10403H) based upon 3'" party pressure testing they analyzed, allowing the following material to provide the equivalent performance of the outward opening attic hatch: Rockfon "Pacific" Ceiling Tiles, by Roxul — Model 201 Square Edge (cut to fit code compliant 22" x 39' [or larger] scuttle hole opening, laid on%" x W trim) Please visit our website www.spf.basf.com or download the full CCRR-1032 by searching BASF at https://whdirectory.intertek.com BASF Technical Service Department — Codes & Credentials Performance Materials - Construction BASF Corporation • 1703 Crosspoint Avenue, Houston, TX 77054, United States Customer Service: 1-800-888-3342 1 Inside Technical Sales: 1-800-706-0712I w ww.sof.basf.corn Thp standard chnicp in -c;mnnth surface- Pacific° r• The standard choice in smooth surface, value for money tiles. Pacific is Ideally suited to a simple, basic It is available with E-edges for a semi- ceiling when standard sound absorption concealed look and A -edges for an exposed \ is required, grid application, Less than half the weight of traditional ceiling tiles, Pacific is easy to carry, cut and install. ASSORTMENT A15 600x600x15 1.91 100 - System .SY15 A24 �- _600x600x15— - -,.,il 1.9 �- -- - - - 100 �- System SY24XL---I 1200 a600x 15 1.9 100 System SY24 E15 600 x 600 x 15 2.4 100 System SY15 � E24 -600x600x15 2.4 100 - � System SY24XL - ! 1200 x 600 x 15 2.4 400. System SY24 Ms- Minimum ku pen bo —n nn %yyF X1 t r f 1 SOUND ABSORPTION A Sound absorption has been measured in accordance with ISO 354. Sound absorption data %, 0k,, and absorption class are calculated in accordance with 150 11654. Noise Reduction Coefficient (NRC) is calculated in accordance with ASTM C423. IQ 0.9 0.8 0.7 0 0.6 — 0.5 0.4 0.2 0.a 0.1 Thlhness (mm)/ 005z z �0 1� 0 200 4ki) a,, NRC Suspension(w.eu-no x z z • 15/7DO 0.40 0.65 0.65 0.65 0.70 0.70 0.70 C 0.65 FIRE PERFORMANCE General: Rockfon ceiling tiles have a core of stone wool, Stone wool is non- combustible with a melting point of more than 1000°C. Reaction to fire: Class Alin accordance with EN 13501-1. Fire Protection: The fire resistant properties of stone wool ensure Rockfon ceiling tiles provide fire protection in construction. The fire protection properties of Rockfon, ceilings have been tested and classified in accordance with European norm EN 13501-2 and/or national norms depending on requirements in national building codes. HUMIDITY RESISTANCE AND DIMENSIONAL STABILITY (FLEXURAL TENSILE STRENGTH) Rockfon ceiling tiles are dimensionally stable even at humidity levels of up to 1 OM/6 RH and can be installed at all temperatures ranging from 0°C to 400C. No acclimatisation is necessary. Pacific is classified as Class 1/C/0N in accordance with EN 13964. However, certain module sizes (width above 700 mm) are class [2/C/ONI ®LIGHT REFLECTION White, 85% diffuse light reflection in accordance with ISO 7724-2. I ®HYGIENE Stone wool has no nutritional value and therefore it provides no sustenance to harmful microorganisms. (� CLEANING U� The surface can be vacuum cleaned with a soft brush attachment. ®AFTERCARE The tiles can be post factory treated with a re -finishing paint, e.g. a PVA water based latex paint. The paint should be applied with an airless spray in a low amount (no brushing or rolling). Rockfon advises the use of the smallest amount of paint in order to minimise reduction in sound absorption. The surface of the tiles must be clean and dry and the existing paint surface must be firmly adhered to the file prior to refinishing. Heavily discoloured tiles should be replaced. Disclaimer: The application of refinishing paint will influence acoustic properties and fire safety performance. Rockfon takes no responsibility for these properties after treatment. ®ENVIRONMENT A representative selection of Rockfon products have been awarded the Danish Indoor Climate label and the Finnish Indoor Climate Label (Ml). Pacific is recyclable. 02.2011 ACTIVATE YOUR CEILING Rockfon® develop intelligent ceiling solutions which actively address a number of important issues in modern buildings and renovation projects Rockfon products are known for their design, aesthetics and ease of Installation; coupled with the key performance features of superior fire resistance and acoustics. This ensures that our ceiling solutions are among the highest performing, most cost effective and time efficient in today's Interiors market. The comprehensive ceiling solution portfolio from Rockfon ensures that our customers are able to actively add value to the construction process, by ultimately creating superior interior environments. That is why we say "ACTIVATE YOUR CEILING". Rockfon (Rockwool AIS) Hovedgaden 501 DK-2640 Hedehusene Denmark Tit: (+45) 46 56 85 45 Fax: (+45) 46 56 40 30 www.rockfon.com export®rockfon.com All colour codes mentioned are based on the NCS - Natural Colour System00 property of and used on licence from NCS Colour AB, Stockholm 2010 Subject to alterations in range and product technology without prior notice. Rockfon accepts no responsibility for printing errors. Local Rockfon dealer 4 OFFICE USE ONLY: 4 DATE FILED: d' "7 REVISION FEE: -k-11 p0 PERMIT # 4 15 V ^ O� RECEIPT # _L6 PLANNING & DEVELOPMENT SERVICES RECEIVED BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 AUG 2 8 2019 (772)462-1553 ST. Lucie County, P D APPLICATION FOR BUILDING PERMIT REVISIONS BY PROJECT INFORMATION St. Lucie County LOCATION/SITE DETAILED DESCRIPTION OF PROJECT RFViCT(1NRe r CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE CO CEjT. #: BUSINESS NAME: c GZuGii�g�G� QUALIFIERS NAME:1�,�}� Ll� nyiZr ADDRESS: , 42S/ nJG ' 09 CITY: &daj' STATE: FLZIP: Z-3179 PHONE(DAYTIME):77$b-,Tg7-L%7a FAX: OWNERIBUILDER INFORMATION: NAME: /}/ocCr AaC-z ��H s��a .�1.���, !C C--- ADDRE�' CITY: Ynn i c /_.�c STATE: �/ ZIP: Z.V19Se(z PHONE (DAYTIME: FAX NAME: ygV / ADDRESS: CITY: PHONE (DAYTIME): INFORMATION: STATE: PAA: ZIP: SLCCC: 9123109 Revised 06130117 FILE COPY REVIRION CJ FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE Rt GUIvtu AUG��7 fir. Lucie County, Permitting F INSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: NOEL RESIDENCE Builder Name: RAPHAEL HENRI Street: 12103 RIVERBEND ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or epsting New (From Plans) 9. Wall Types (4110.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Erd Insul, Exterior R=4.1 3750.00 ft2 b. Frame- Wood, Adjacent R=13.0 360.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (4747.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=30.0 4747.00 ft2 6. Conditioned floor area above grade (ft2) 4746 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(742.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU 1 6 200 a. U-Factor: Sgl, U=0.58 486.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 125 SHGC: SHGC=0.24 c. Sup: Attic, Rat: Attic, AH: Attic 6 125 b. U-Factor: Sgl, U=0.65 168.00 112 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 46.5 SEER:16.00 b. Central Unit 17.9 SEER:16.00 c. U-Factor: Sgl, U=0.33 88.00 ft2 c. Central Unit 17.9 SEER:16.00 SHGC: SHGC=0.16 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft a. Electric Strip Heat 34.0 COPA.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 6.147 ft. c. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average SHGC: 0.224 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (4746.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 4746.00 ft2 b. Conservation features b. WA R= ft None c. WA R= ft2 15. Credits None Glass/Floor Area: 0.156 Total Proposed Modified Loads: 131.29 PASS Total Baseline Loads: 140.48 I hereby certify that the plans and specifications covered by Review of the plans and STgpA this calculation are in compliance with the Florida Energy specifications covered by this �4KSE Code. calculation indicates compliance with the Florida Energy Code. PREP DM�QSMAR266IM20 Before construction is completed' DATE: v� this building will be inspected for compliance with Section 553.908 . -. t- a I hereby certify that this building, as esigned ' in compliance Florida Statutes. with the Florida Energy Code. COp (Rv OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). / /o I- d0 SZ EV1E3 1®N FSLEC®PY 8/21/2019 2:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: NOEL RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 4746 Lot# Owner Name: Total Stories: 1 Block/SubdMslon: # of Units: 1 Worst Case: No PlalBook: Builder Name: RAPHAEL HENRI Rotate Angle: 0 Street: 12103 RIVERBEND RO Permit Office: ST LUCIE COUNTY Cross Ventilation: County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: City, State, Zip: PORT ST LUCIE, Family Type: Single-family FL, New/Ebsting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2914 29140 2 Block2 908 9080 3 Block3 924 9240 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 AHU 1 2914 29140 Yes 0 2 1 Yes Yes Yes 2 AHU 2 908 9080 No 0 0 1 Yes Yes Yes 3 AHU 3 924 9240 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation AHU 1 159 It 0 2914 ft' __ 1 0 0 2 Slab -On -Grade Edge Insulation AHU 2 70 ft 0 908 ft2 1 0 0 3 Slab -On -Grade Edge Insulation AHU 3 122 ft 0 924 ft2 __ 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 5308 ft2 0 ft2 Medium N 0.6 No 0.9 No 30 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RSS IRCC 1 Full attic Unvented 0 4746 ft2. N N 8/21/2019 2:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvenled) AHU1 0 Blown 2914 ft2 0.11 Wood _ 2 Under Attic(Unvenled) AHU2 0 Blown 908 ft' 0.11 Wood 3 Under Attic(Unvenled) AHU3 0 Blown 925 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 E Exterior Concrete Block- Ext Insul AHU 1 4.09999 34 10 340.0 ft2 0 0 0.600000 0 _ 2 S Exterior Concrete Block - Ext Insul AHU 1 4.09999 42 10 420.0 ft' 0 0 0.600000 0 _ 3 W Exterior Concrete Block- Ext Insul AHU 1 4.09999 65 10 650.0 ft' 0 0 0.600000 0 4 N Exterior Concrete Block - Ext Insul AHU 1 4.09999 28 10 280.0 ft2 0 0 0.600000 0 _ 5 E Exterior Concrete Block - Ext Insul AHU 2 4.09999 30 10 300.0 ft2 0 0 0.600000 0 _ 6 W Exterior Concrete Block - Ext Insul AHU 2 4.09999 22 10 220.0 W 0 0 0.600000 0 _ 7 N Exterior Concrete Block - Ext Insul AHU 2 4.09999 32 10 320.0 ft2 0 0 0.600000 0 8 E Exterior Concrete Block - Ext Insul AHU 3 4.09999 27 10 270.0 ft2 0 0 0.600000 0 _ 9 S Exterior Concrete Block - Ext Insul AHU 3 4.09999 47 10 470.0 ft2 0 0 0.600000 0 _ 10 W Exterior Concrete Block - Ext Insul AHU 3 4.09999 31 10 310.0 ft2 0 0 0.600000 0 11 N Exterior Concrete Block - Ext Insul AHU 3 4.09999 17 10 170.0 ft2 0 0 0.600000 0 _ 12 E Garage Frame - Wood AHU 1 13 28 10 280.0 ft' 0 0.25 0.600000 0 13 N Garage Frame - Wood AHU 1 13 8 10 80.0 ft2 0 0.25 0.600000 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Single Yes 0.58 0.24 N 48.0 ft2 6 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 E 1 Metal Low-E Single Yes 0.58 0.24 N 36.0 ft2 6 ft 0 in 1 It 4 in Drapes/blinds Exterior 5 3 E 1 Metal Low-E Single Yes 0.65 0.21 N 48.0 ft2 6 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 4 S 2 Metal Low-E Single Yes 0.65 0.21 N 48.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 5 S 2 Metal Low-E Single Yes 0.58 0.24 N 18.0 112 14 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 6 S 2 Metal Low-E Single Yes 0.58 0.24 N 48.0 ft2 14 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 7 S 2 Metal Low-E Single Yes 0.33 0.16 N 21.3 ft2 14 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 8 W 3 Metal Low-E Single Yes 0.33 0.16 N 18.7 ft' 14 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 9 W 3 Metal Low-E Single Yes 0.65 0.21 N 72.0 ft2 14 It 0 in 1 ft 4 in Drapes/blinds Exterior 5 10 W 3 Metal Low-E Single Yes 0.58 0.24 N 36.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 11 W 3 Metal Law-E Single Yes 0.58 0.24 N 12.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 12 N 4 Metal Low-E Single Yes 0.58 0.24 N 12.0 ft' 1 ft 6 in 1 It 4 in Drapes/blinds Exterior 5 13 N 4 Metal Low-E Single Yes 0.58 0.24 N 18.0 ft' 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 14 N 4 Metal Low-E Single Yes 0.33 0.16 N 24.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 15 E 5 Metal Low-E Single Yes 0.33 0.16 N 24.0 ft2 1 ft 6 in 1 It 4 in Drapes/blinds Exterior 5 16 E 5 Metal Low-E Single Yes 0.58 0.24 N 12.0 ft' 1 ft 6 in 1 It 4 in Drapes/blinds Exterior 5 17 W 6 Metal Low-E Single Yes 0.58 0.24 N 36.0 ft' 1 ft 6 in 1 It 4 In Drapes/blinds Exterior 5 18 N 7 Metal Low-E Single Yes 0.58 0.24 N 48.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 19 E 8 Metal Low-E Single Yes 0.58 0.24 N 16.0 ft2 1 ft 6 in 1 ft4 in Drapes/blinds Exterior 5 20 E 8 Metal Law-E Single Yes 0.58 0.24 N 12.0 ft' 1 ft 6 in 1 ft4 in Drapes/blinds Exterior 5 8/21/2019 2:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 J FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Inl Shade Screening _ 21 22 _ 23 _ 24 25 S 9 Metal Low-E Single S 9 Metal Low-E Single W 10 Metal Low-E Single W 10 Metal Low-E Single W 10 Metal Low-E Single Yes Yes Yes Yes Yes 0.58 0.24 N 24.0 ft' 1 fl6 in 1 ft 4 in 0.58 0.24 N 36.0 ft' 1 fl6 in 1 ft 4 in 0.58 0.24 N 18.0 ft' 10 ft 0 in 1 ft 4 in 0.58 0.24 N 24.0 1112 10 ft 0 in 1 ft 4 in 0.58 0.24 N 32.0 ft' 10 It 0 in 1 ft 4 in Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Exterior 5 Exterior 5 Exterior 5 Exterior 5 Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 812 ft' 812 ft2 36ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 5537 303.97 571.67 .1685 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 _ 2 3 Electric Strip Heat/ Electric Strip Heat/ Electric Strip Heat/ None None None COPA 34 kBtu/hr COP:1 17 kBtu/hr COPA 17 kBtu/hr 1 2 3 sys#1 sys#2 sys#3 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 3 Central Unit/ Central Unit/ Central Unit/ None None None SEER: 16 46.5 kBtu/hr 1395 cfm SEER: 16 17.9 kBtu/hr 537 cfm SEER: 16 17.9 kBtu/hr 537 cfm 0.8 1 0.8 2 0.8 3 sys#1 sys#2 sys#3 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPm Conservation 1 Electric None Garage 0.98 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Carl # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 8/21/2019 2:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS — Supply— -- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 200 ft' Attic 20 ft' Default Leakage AHU 1 (Default) c(Default) c 1 1 2 Attic 6 125 ft' Attic 13 ft2 Default Leakage Attic (Default) c(Default) c 2 2 3 Attic 6 125 ft' Attic 13 ft' Default Leakage Attic (Default) c(Default) c 3 3 TEMPERATURES Thermostat: ProgramableDec Ceiling Fans:Cooli tp :X'�N FebrD(�� f Mayrr fr Julfr n ri ri �[X]] r r[X'] Nov fNovrX]� Dec Venting [ ] Jan [ ] Feb [X] Mar Apr May Jun Jul Aug [) Sep Ocl [X] [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78. 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 8/21/2019 2:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 5 of 6 FORM R4O5-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 Oft 0.3 AHU 1 CLST Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 DINING Default(8 lbs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8 lbs/sq.ft. ft- ft 0.3 PANTRY Default(81bs/sq.ft. ft2 ft 0.3 LIBRARY Default(8 lbs/sq.ft. ft2 It 0.3 LAUNDRY Default(81bs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 POWDER RM Default(8 lbs/sq.ft. ft2 ft 0.3 AHU 2 CLST Default(81bs/sq.ft. ft2 ft 0.3 LINEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 3 Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 lbs/sq.ft. ft2 ft 0.3 CABANA Default(8 lbs/sq.fl. ft2 ft 0.3 CLST 4 Default(8 lbs/sq.ft. ft2 ft 0.3 HALLWAY Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 4 Default(8 lbs/sq.ft. ft2 ft 0.3 M SPA Default(8 lbs/sq.ft. ft2 ft 0.3 MTOILET Default(8 lbs/sq.ft. ft2 ft 0.3 MASTER SUITE Default(8 lbs/sq.ft. ft2 ft 0.3 MWIC Default 8 Ibs/s .ft. ft2 ft 0.3 M HALL 8/21/2019 2:42 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: NOEL RESIDENCE Builder Name: RAPHAEL HENRI Street: 12103 RIVERBEND ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE , FL, Permit Number: Ne U Owner: Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation In an dropped ceiling/soffit y pp 9 /soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be Insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing.shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,,penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow,cavilies cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Plates and walls or ceilings, a. ui uumuou, nisyecuun ur lug wars snaii be In accoroance with me provisions of IL1G-4uu. 8/21/2019 2:43 PM EnergyGaugeg) USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 S Pro ect Summary at -��- wrightsofte � � Date: AUGUST 27, 2079 AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: OUICKCALCS@AOL.COM Project• • For. NOEL RESIDENCE, RAPHAEL HENRI 12103 RIVERBEND ROAD, PORT ST LUCIE, FL 34984 Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range Relative humidity M 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 29294 Btuh Structure 27419 Btuh Ducts 9359 Btuh Ducts 8226 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 38652 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 33863 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4460 Btuh Ducts 3724 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cooling (none) Area (ft� 2914 2914 Equipment latent load 8185 Btuh Volume (ft� 35970 35970 Airchangesrhour 0.22 0.12 Equipment Total Load (Sen+Lat) 42047 Btuh Equiv. AVF (cfm) 132 71 Req. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6049J1 AHRI ref Coil TEM4AOC48S41++TDR 8676081 Efficiency 100 EFF Efficiency13.5 EER, 16 SEER Heating input 9.6 kW Sensible cooling 32550 Btuh Heating output 32842 Btuh Latent cooling 13950 Btuh Temperature rise 19 OF Total cooling 46500 Btuh Actual air flow 1550 cfm Actual air flow 1550 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed 41- wrIahtsoR- 2019-Aug-21 14:28:05 �A ^"""' ^•'""^` Right -Suite® Universal 201919.0.08 RSU08101 Page 1 ...Wnghlsoft WAC\NOEL RESIDENCE WITH CYNENE.mp Calc=10J8 Front Doorfaces: E +�- wrightsoft- Project Summary AHU2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: For: NOEL RESIDENCE, RAPHAELHENRI 12103 RIVERBEND ROAD, PORT ST LUCIE, FL 34984 N otes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Job: Date: AUGUST 21, 2019 By: Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 13064 Btuh Ducts 2179 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 15243 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heatingg Coolingg Area (ft� 908 908 Volume (" 11992 11992 Airchanges/hour 0.34 0.18 Equiv. AVF (cfm) 67 36 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 3.7 kW 12472 Btuh 19 OF 597 cfm 0.039 cfm/Btuh 1.00 in H2O 90 OF 75 OF 15 M OF 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 10151 Btuh Ducts 3078 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data In Rate/swinqq multiplier 0.95 Equipmenfsensible load 12568 Btuh Latent Cooling Equipment Load Sizing Structure 2505 Btuh Ducts 798 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 3302 Btuh Equipment Total Load (Sen+Lat) 15870 Stuh Req. total capacity at 0.70 SHR 1.5 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TTR6018B1 Coil TEM6AOB24H21++TDR AHRI ref 7567552 Efficiency 13.0 EER, 16 SEER Sensible cooling 12530 Btuh Latent cooling 5370 Btuh Total cooling 17900 Btuh Actual air flow 597 cfm Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. w.r:ghtsofC- 201&Aug-21 14:age 2 .A RESIDENCE WITH Universal 2019 1 Calc RSU08101 Page 2 ...WrightsoR HJACINOEL RESIDENCE WITH ICYNENE.nip CaIc=MJB Fronl Door hces: E Pro ect Summar Joe +� wrightsoftm AHU 3 y By AUGUST 21, zots QUICK CALCS, INC. 317 STLUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fa1c 772A66-6796 Email: ONCKCALCS@AOL.COM ject Information For: NOEL RESIDENCE, RAPHAEL HENRI 12103 RIVERBEND ROAD, PORT ST LUCIE, FL 34984 Notes: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TO 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 14285 Btuh Structure 9992 Btuh Ducts 2274 Btuh Ducts 3197 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16559 Btuh Use manufacturer's data n Rate/swing multiplier Equipmenf 0.95 Infiltration sensible load 12529 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2379 Btuh Ducts 829 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none Area (ft� 9N 924 Equipment latent load 3208 Btuh Volume (ft� 9908 9908 Air changes/hour 0.43 0.23 Equipment Total Load (Sen+Lat) 15737 Btuh Equiv. AVF (cfm) 71 38 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018B1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567552 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 4.4 kW Sensible cooling 12530 Btuh Heating output 14962 Btuh Latent cooling 5370 Btuh Temperature rise 23 OF Total cooling 17900 Btuh Actual air flow 597 cfm Actual air flow 597 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wY tights �ft- 2019-Au9-21 14:28:05 —%=ACC'Right-Suite® Universal 201919.0.08 RSU08101 Page 3 ;..Wnghtsoft WAC\NOEL RESIDENCE WITH ICYNENE.mp Calc = MJ8 Front Door tacos: E +� wrightsofC Right-M Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A68-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room nacre Exposed wall Room height Room dimensions Room area AHU 1 171.3 It 12.3 ft 2913.5 fit' KITCHEN 21.0 It 13.0 It heat/cool 1.0 x 565.5 It 565.5 ft' Ty Constnrction number U-value (Btut✓ftt°F) Or HTM (BtuWftO Area (ftj or perimeter (rt) Load (Btuh) Am (ft0 or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 8 11 V�! 1w �--_G W_ ._ G l?/ �C _ ! a �Rl IL- UW/,! G W Cy- _ F 13A4ocs -.'- 2.91azin9„dr.lvi7;e 13AAws 2 alazire. clr Iove.�, '13A-4= 2 glazing,.dr lox-e_ 134-0acs 2 glazing, dr IaN-e _ 13A-0ocs 2 glazing, drI=-e_ ISAA cs alazi _or Iox_e _ 134-4acs 2 glazin ,.dr.lowe._ 13AAoss 2 plazinp, clr loxes 22A-tph ----0343 .._ _.0.650 0.143 _`0.650 0.143 -0.6W 0.143 0.650 ._ 0.143 `0.650 0.143 _` 0 650 0.143 , 0.650 0.143 0.650 _ 0.408 1.358 n ._n_ ne ne- _ e _e_ se s_ e - s _a_ sw _sw vr- _w_ rtw my _ . 4.00 -18.20 4.00 18.20 4.00 -18.20 4.00 18.20 -4.00 __18.20 4.00 18.20 '-4.00 __ 18.20 0.00 0.00 _- _1.18 38.02 ­--fig280 _14.99 219 26.88 219 __.33.77 219 _27.05 2.19 ___16.03 219 ^ 27.05 219 -33.77 O.Oo �O.Oo 0.79 ` 0.00 __54 59 18 -413 __.96 59 16 226 _ _____0 42 __ 0 _317 0 42 0 - - 369 __O 69 _ 0 861'- 0 0 0 0 0 291 ,._4 171 903 , _ 983 168 318 ___1269 1747 168 318 _v 1479 _2051 278 409 2645 __2536 0 _ 0 .- -- 3433 6515 494 -_810 92 470 __694 ,_3242 92 473 _608 �1806 152 609 1445 _4706 0 _ 0 2309 0 ___O ---0 __ -'0 0 ____O 0 0 -----0 ____O 0 0 -309 _ 652 152 _,609 0 ._._.--0 0 0 - _448 0 , _0 0 0 ­0 0 0 0 182 41 92 _23 0 __.._0 __0 0 _ 0 _0 ___0_ 0 0 n 141 40 `0 0 0 0 - _0 0 __ 0 "� 566 ___740 278 ,_409 0 __O _ 482 __113 92 _ 23 800 _._ 139 _ „_2914 2914 69 _^_ 0 0 _0 0 0 =566 566 0 _- _, 0 566 21 0 0 -_-_666: 799 __.__. 6 c)AED excursion 0 -192 Envelope loss/gain 25223 18201 3458 1977 12 a) Infiltration b) Room ventilation 4071 0 1168 0 510 0 146 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 8050 0 0 2000 SLbtotd Qines 6 to 13) 29294 27419 3969 4124 14 15 Less exdemal load Less transfer Redistribution Subtotal Dud load. M. 30% 0 0 0 M94 9359 0 0 0 27419 82M 32% 30% 0 0 57 4026 1286 0 0 35 4159 1248 Total room load Air required (dim) 38652 1550 35645 1550 5312 213 5407 235 Calculations approved bvACCA to meet all requirements of Manual J Sth Ed rtl} wggft�oTt- 2019-Aug-21 14:28:05 Right -Suite® Universal 201919.0.08 RSU08101 Page 1 ...Wrighlsoft HUACWOEL RESIDENCE WITH CVNENE.mp Calc=MJ8 Front Ooorfaces: E wrIgtltsoft' Right-J® Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room narne E'gxsed wall Room height Room dimensions Room area FAMILYROOM 40.0 It 15.0 It heat/cool 1.0 x 395.0 ft 395.0 ft' AHU 1 CLST 0 It 10.0 ft heat1cool 3.0 x 7.0 It 21.0 IMP TY Construction number U-%slue (etuh/fti'F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (M a perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 -G. 13A 1 2 glaz(ng, GClowe- 13A-4= 2 0mina dr laue__ 13A-0ccs glming,.drlome-'_-_0.650 13q-0ocs 2 glazing, Ur low-e 2 gladng,.clGlowa_ 13A-4ocs 2 plazinp Ur love_ 13A46cs - 2 glazing,.Gr Mw,e- lakil s 2 plazing, or low-e _ 16X3D.Ottl___ 22A-tph,_ -07143 .____0.650 0.143 .,_0.650 '0.143 0.143 0.650 0. 143 _0.650 0.143 0.650 --0:143 - _.0.650 0.143 _ __0.650 __ 0,408 1.358 n ._n_ ne _ne_ a _e_ se se s -_s._ sw _ sw W _w_ w nw __-_ 4A0 �18.20 4.00 _18.20 4.00 _18.20 4.00 18.20 4.00 _ _ 18.20 4.00 18,20 ' 4.00 -18.20 0.00 0.00 138 38.02 219 ,_.,,14.99 219 __ 26.88 219 -33.77 219 27.05 2 19 16.03 2.19 __27.05 219 _.33.77 0.00 0.00 -'0.79 0.00 -- 0 0 0 0 ---0 -0 0 _ 0 - M0 --72 0 0 --0 ___ _ U _--._0 0 _ 0 �0 -_0 0 _ 0 -913 ,.1310 0 0 -- 1201 -A 0 0 _ _ 465 1521 -__0 ~ -.0 ---0 _--0 0 _ _,__ 0 0 _0 0 0 --0 --0 0 _ 0 0 0 0 0 -0 -.__._0 0 0 -- -0 -__0 0 0 WW �C. W, G W L-C L-a -.--0 0 _ 0 _0 -__.-0 0 0 --_ M8 0 0 _ 0 � �300 _-0 0 _ 0 _ _395 40 ,.-0.-0 0 _ 0 _ -'0 --0 0 0 - 499 �1154 0 0 0 _ y0 0 -___0 0 0 --0 _-- 0 0 0 ---0 _0 0 _ 0 ,21 21 --0 ,__ 0 0 0 --0 -0 0 0 �21 0 --0 .__0 0 0 --- 0 0 0 __ 0 _ _25 ---0 .__..0 0 0 '-- --0 -0 0 _ _ 0 __77 0 W -' IW-'-� _ �-G WI - ,Cc �, ,-,_ F �300 ----0 0 0 '-'- 895 ��395 '- 856 __-0 0 _ 0 =313 0 ---0 -, 6 c)AED ecursion -77 _1 Envelope loss/gain 5411 2545 25 15 12 a) Infiltration b) Room ventilation 1117 0 321 0 0 0 0 0 13 Internal gains: Occupams @ 230 Appliances/other 0 0 0 0 0 0 Subtotal Qines 6 to 13) 6528 2866 25 15 14 151 Less eternal load Less transfer Redistdbution Subtotal Duct loads 32% 301. 0 0 4 6532 2087 0 0 2 2868 861 M. 30% 0 0 -25 0 0 0 0 -15 0 0 Taal room load Air required (cfm) 8619 346 3729 162 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed A 46- wrlgtitsoiC- 2019-Aug-21 14:28:05 Right-Sulte® Universal 2019 19.0.08 RSU08101 Page 2 ...Wnghtsoft HVACINOEL RESIDENCE WITH ICYNENE.rup Calc = MJB Front Door faces: E + wrightsotr Right-JO Worksheet AHU1 QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUCKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room name 6yosed wail Room height Room dimensions Room area OFFICE 17.2 ft 14.0 ft heat/cod 1.0 x 229.5 ft 229.5 ft' FOYER 7.0 ft 13.0 ft heat/cool 1.0 x 164.0 ft 164.0 ft2 Ty Construction number U-value (BtulVftk'F) Or HTM (Btuh/ft2) Arm (ft2) or perimeter (ft) Load (Btuh) kee (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cod Gross WKS Heat Cool 8 11 1� - G 13A-flocs 2 glazing, dr,lovre_ 13A-4ocs 2 plazinp, Gr lov_e 13A-4 c 2 glazing,.ciclav-e.._._ 13AAccs 2 glazing, dr lav-e 13AA= 2 glazing„dr.1=e, _ 13A4= 2 plazinp. clr lox_e laA40M - 2 glazing,.dr love_ 0.143 __0.650 0.143 _ 0.650 -0.143 a.._.0.650 0.143 0.650 - n ;n_ ne _ne- a __a_ se se 4.00 _.18.20 4.00 _18.20 4.00 __18.20 4.00 18.20 4.00 _18.20 4.00 18.20 -4.00 -18.20 ---2.19 _14.99 219 _26.88 219 -33.77 219 27.05 -2.19 _16.03 219 27.05 --- 2-19 ,33.77 0 0 ` 0 _-_0 42 0 ----0�`"0 __0 168 318 -�633 _-437 0 0 __ .__-0 0 0 00 __0 92 470 -' -346 -811 0 0 -0 0 0 ----0 __0 0 0 0 0 JO ___ 0 0 0 -- -94 ___1621 0 0 -----o _0 __ -__0 0 _ _0 '- 0 ---0 WI !--G - yJ' W L-G Y--G -__ 59 18 ' 182 -......24 0 0 ' --'-0 „-0 0 0 0 __-0 _0 0 0 �- -91 ..--...._48 0 0 __..- 0 __0 0 _0 0 -0 0 _ 0 172 ..._-874 0 0 -_.0 0 158 ___.__0 0 0 .- _ 0 43 -0 0 0 _,.___0 0 '---0-143 „0.650 0.143 0.650 �0.143 -0.650 _.143 s _s_ sw sw �w - _w_ y/ .W�. -0 0 0 "'0' _0 0 0 0 _ 0 „ -0 _ 0 _0 --- 0 ^0 0 --0 0 0 IW -G �_;_ C F 13AAccs 2 glazing, clr lovr_e 16X30-0td� _-__ 22A-ttph__^ 0.143 Q650 :l0.408 1.358 my my - i 0.00 0.00 ,-1.18 38.02. 0.D0 _ 0.D0 --0.79 0.00 0 0 -230 230 0 0 �_ - 230 _ 17 0 0 T.,, 270 653 0 0 `782 0 0 0 ,_,�.. 164 164 0 0 ,� J764 7 0 0 � 193 266 0 0 �'."130 0 _ __ _ _ 8 c)AED excursion -217 -122 Envelope loss/gain 2479 1683 1505 1723 12 a) Infiltration b) Roomvedilation 450 0 129 0 169 0 49 0 13 Interne] gains: Occupants @ 230 Appliances/other 0 0 600 0 0 600 Subtotal (fines 6 to 13) 2928 2412 1675 j M71 14 15 Less eMemal load Less transfer Redistribution Subtotal Dud loads 32% 30% 0 0 534 3463 1106 0 0 757 3169 951 32% 30% 0 0 -1675 0 0 0 0 -2371 0 0 Total Haan load Air required (cfm) 4569 183 4120 179 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed ACA +F1- wr19F+>�of'e- 2019-Aug-21 14:28:05 Right-E WT UniversalNE.wp 1 Catc RJB Fr1 Page 3 ...Wdghtsofl HVAC\NOEL RESIDENCE WITH ICYNEt�.mp CaIc=MJB Fronl Door faces: E _ 1 + wrightsoft Right-M) Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466.6796 Email: OUICKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room name Flyosed wall Room height Room dimensions Room area LMNG ROOM 12.0 ft 15.0 ft heat/cool 1.0 x 167.0 ft 167.0 ft' HALLWAY 0 ft 10.0 ft heat/ccol 1.0 x 104.0 It 104.0 ft' Ty Construction number U-value (Bt0vftk°F) Or HTM (BtuNft� Arm (ftj or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Bluh) Heat Cool Gross NIPIS Heat Cod Gross WP/S Heat Cod 6 11 W, 13A-0ac9 2 glazing, cI Iov_e_ 13A-4ocs 2 olazing-or Iowa 134-0ms 2 glazing„clr.la _. 13A-4= 2 glazing, or lov-e r13A-4ocs 2 glazing„drlcw a -; 13AAccs 2 olazino, clr lc v e_ "13A-0dcs 2glazing„ciclwv-e.._ 13A-0ac9 2 olazinm dr Io _ _16X300ttl 22A-tph � _ _1.358 ___0_. 143 -_-0.650 0.143 __ 0.650 0.143 -_0.650 0.143 __ 0.650 0.143 _ 0.650 0.143 �0.650 0.143 _0.650 0.143 0.650 _ �0.408 n _n_ no _ne_ a _e_ se se s_ -s_ sw _ sw_ w _w_ nw nw _, - _ 4.00 18.20 4.DD ,_18.20 4.0D __1B.20 4.00 18.20 4.00 `18.20 4.00 ,_ 18.20 4.00 __18.20 0.00 1_.18 38.02 --219 14.99 `--__.._0 �.�,.0 ­0.--.._-0 0 0 _-.__0 0 ­0. 0 0 --.d0 W W, � - - �G W �G h^ 219 26.88 '- 219 _.33.77, 219 __ 27.05 219 _-16.03 219 _2.7.05 219' _ _33.77 0.00 0.00 _ _0.79 0.00 __0 0 00 --0 0 0 ___0 .-,--_.0 0 0 180 __72.___0.__._1310 0 0 ___0 0 0 0 .-__�0 0 0 __0 ___ _0 0 0 432 0 0 ___197 456 _0 0 0 -_0 0 0 0 0 __.._..0._ 0 0 -_0 0 0 _0 0 0 0 0 0 -_0 .__0 0 0 -`_0 _____0 0 0 0 0 0 __0 _0 0 0 .______a ._ _ _._..0 0 0 -_--0 0 -...____0 0 0 236 _-2432 0 0 � 132 0 VN �G __0 0 0 0 0 __�0 0 0 __0 0 0 �_123 0 __a 0 0 -0 0 0 � 82 0 W-�- W 'C.0.00 7 ,_ F _ 108 0 0_ 0- 0 0 0 , �1 04 104 0.---0-_.__._0 ___0 0 0 _ 167 167 �767 12 _ �104 0 _ _ _ 6 c)AED excursion 703 -7 Envelope loss/gain 2396 3503 123 76 12 a) Infiltration b) Room ven8lation 335 0 96 01 0 0 0 0 13 Internal gains: Occupants @ 230 Applianceslother 0 0 0 0 0 0 Subtotal pines 6 to 13) 2731 3599 123 76 14 15 Less eldemal load Less transfer Redistribution Subtotal Dud loads 32°/. 30% 0 0 606 3337 1066 0 0 858 4457 1337 3rA 30% 0 0 -123 0 0 0 0 -76 0 0 Total room load Air required (dm) 4403 177 5794 252 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed +}+- wrlgtitsoR- 2019.Aug-21 14:28:05 A Right -Suite® Universal 2019 19.0.08 RSU08101 Page 4 ...Wrightson HVAC\NOEL RESIDENCE WITH ICYNENE.rup Cate = MJB Front Door faces: E +�+ wrightsoftRight-JO Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-468-6796 Email: QUICKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Roomname EJposedwall Room height Room dimensions Room area DINING ROOM 14.2 ft 14.0 ft heat/cool 1.0 x 229.5 It 229.5 ft' LAUNDRYROOM 19.0 It 10.0 It heat/cool 1.0 x 237.0 ft 237.0 ft2 TY Construction number U-lalue (Btuh/WF) Or HTM (Btuh/ft� Araa (ft2) or permeter (ft) Load (Btuh) Aron (ft0 or perimeter (It) Load (Bluh) Heat I Cool Gross NIP/S Heat Cad Gross N/P/S Heat Cool 6 11 V14�JJ 13X4 - glazing, cldcwo -_. 13A40cs 2 olazim clr lc u e 13A4ccs � 2gluing, ciclowe__ 13A-0acs 2 glazing, Ur love 13A4&s ^ 2 glazing_ciclowe_ 13A-4ocs 2olazino,_JrIa -1344dcs 2 glazing,.ciclow - 13A4ocs 2glazing, clr lc- a J6X30-0td__�' 22A-tph 0143 ,,.-_0.650 0.143 0.650 -0.143 _0.650 0.143 0.650 0.143 _-_.0.650 0.143 0.650 --0.143 -0.650 0.143 0.650 _0.408 1.358 'n _. _n_ ne _ne_ a _e_ se se s _,s_ sw sw -�w _w_. my mv_ _�_ - 4.00 _18.20 4.00 _18.20 4.00 -16.20 4.00 18.20 - 4.00 _-16.20 4.00 _ 1&20 4.00 _18.20 0.00 _0.00 -� 1.18 38.02 219 -_14.99 219 _26.88 219 -33.77 2.19 27.05 -2.19 '--0 -0 0 0 r--740 -24._-0 ----0 -_0 0 __ 0 116' -- -70 __-_0 0 _ 0 464 _.__437 0 ,___0 0 _20 54 ,_811 92 473 -- -0 -150 36 0 0 -114 0 456 _^655 0 _ _ 0 s--0 -0 249 _540 0 __ 0 - v0 -__0 0 0 -----0 -I-_.G. W _ L--G WW L-G W LC U}J Lf 0 _0 0 _-_0 0' ._.___.0 59 18 42 0 168 318 0 0 ---- 0 0 0 --0 _,0 0 0 0 0 0 0 --0 --J-0 0 YtJ �--G W-` - _L-G W L-G C= F _16.03 219 _27.05 218 -33.77 0.00 0.00 _0.79 _0.00 -_0 0 0 ----0 0 0 ---0 -0 0 0 _230 14 ___0 0 0 -- --0 -0 0 0 - 270 539 �0 0 0 - 0 0 -0 0 0 160 -_0 0 0 _ _279 722 -0 0 0 ----88 -_0 0 0 0 0 -0 0 0 - 230 i230 0 _-.-_0 0 0 =182 0 40 -0 0 0 _=237 237 40 0 0 0 ._ 237 19 --_ 6 c)AED excursion -182 -96 Envelope loss/gain 2197 1629 2274 968 12 a) Infiltration b) Roomeehtilalion 371 0 107 0 354 0 102 0 13 Internal gains: Occupants @ 230 Applianceslother 0 0 600 0 0 0 Subtotal pines 6 to 13) 2568 2336 2627 1070 14 15 Less edema) load Less transfer Redistribution Subtotal Dud loads 32% 30% 0 0 582 3150 1006 0 0 786 3122 937 32% 30% 0 0 11 2639 84 3 0 0 7 1077 323 Total room load Air required (cfm) 4156 167 4D58 176 3482 140 1400 61 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed , 4-Ih- wrrgF„tsoft- 2019-Aug-21 14:28:05 Right -Suite® Unisersal 2019 19.0.08 RSU08101 Page 5 ...Wdghtsoft HVAC\NOEL RESIDENCE WITH ICYNENE.rup Calc = MJB Front Door faces: E i +b wrightsoft• Right-JOWorksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: DUICKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room name Eq»sad wall Room height Room dimensions Room am WIC 2 4.0 ft 10.0 ft heat/cool 11.0 x 4.0 It 44.0 ft' PRAYER ROOM 0 ft 10.0 It healfcool 4.0 x 4.0 ft 16.0 W Ty Constnrctim number U-value (BtulVftk°F) Or HTM (BtuMft� Area (ftj or Perimeter (ft) Load (Btuh) Area (ft' or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat. Cool 6 11 W, L=(' 13A4ocs 2glazing, Urlov�-_ 13A-4acs 2 glazing_ctr love ..13A4ccs . __. 2glazing:,cffiloxe__ 13A4ocs 2 glazing, or lore 13A-400s 2g1azing, GrIbw-e, 13A4ocs 2 plazina, Gr low-e 13A4acs_ _ _ _ _ 2 glazing,"cicicw-e.-_ 1344ccs 2 plating, or ow-e J6X30{!td - 22A-tph -0-143 -_-0.650 0.143 0,650 --`-0.143 -_.0.650 0.143 0.650 --o-m ___0.650 0.143 0.650 _0.143 -0.650 0.W _„_,0.650 __-_ 0.408 1.358 -n _n_ ne ne_ a _e_ se se _ - s_ _s_ sw sw vv-. _w_ rxr M _ - _ 4700 _18.20 4.00 __, 1.8.20 `4.00 _.18.20 4.00 18.20 4A0 219 _.14.99 219 26.88 219 _-33.77 219 27.05 -2.19 -40 0 0 0 -0 _-_0 0 0 ---0 40 0,_0'_,0 0 0 _ __.__0 -._-0 0 0 _-'.0 160 0 0_ 98 0 ,_ d 0 0 __0 0 0 -`---0 0 0 _w_0._.__0 0 0 .=35 ---0 0 0 ---0 _,0 0 0 -0 0 v0 ..0 0 0 -.-_-0 -0 0 0 '-. _._ __0 ___O 0 0 0 ._-"_._0 0 0 13 0 W _�[� W _LG W, I--G 0 0 --0 _._0 0 0 __ 0 0 --.0 .___0 0 0 -'-`-0 0 0 --0 0 0 _ - -0 ___O_._.0 0 0 g--0 .�.____0 0 0 -52 152 0 __0 0 0 F d --0 0 -,1-G yr! �-C W _..i- .._L-G 1W W--G F -18.20 4.00 18.20 4.00 -18.20 0.00 0.00 _ _ 1.18 38.02_ _16.03 219 27.05 - 2-19 .-33.77 0.00 0.00 -- 0.79 0.00 __0 0 0 _ 0 __-0 0 0 = 44 44 Tp 0 0 ____.0 : 0 0 0 _ 44 4 _0 0 0 0 0 _. __a -0 0 0 0 0 0 __.-_-_0 0 0 - i9 0 0 0 ".�'i6 16 16 _ _0 ___-0 6 c)AED e=ursion -53 42 Envelope loss/gain 364 69 19 -30 12 a) Infiltration b) Room ventilation 1 74 0 21 0 0 0 0 0 13 Warned gains: Occupards Qc 230 Appliances/other 0 0 500 0 0 500 Subtotal pines 6 to 13) 439 591 19 470 14 151 Less edemel load Less transfer Redistribution Subtotal Duct loads 32% 30% 0 0 0 439 140 0 0 0 591 177 32% 30% 0 0 0 19 6 0 0 0 470 141 Taal room load Air required(ctm) 579 23 7' 33 25 1 612 27 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed +�1- wrigl=tsoR- 2019-Aug-2114:28:05 `p Right -Suite® Universal 2019 19.0.08 RSU08101 Page 6 ...Wnghtsoft HVACINOEL RESIDENCE WITH ICYNENE.mp Calc = MJ8 Front Doorfaces: E • r . +� wrightsofC Right-JO Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772-466-6796 Emil: QUICKCALCSIAOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Rcom area PANTRY 0 it 10.0 ft heatlecol 8.0 x 6.0 it 48.0 It' BEDROOM 2 9.0 It 10.0 it heahccol 15.0 x 14.0 It 210.0 ft' Ty Constructicn number U-value (Btul✓WF) Or HTM (Btuwft� Area (ft') or perimeter (it) Load (Stuh) Area (ft� or perimeter (it) Load (Btuh) Heat Cod Gross N/P/S Heal Cool Gross WP/S Heat Cod 6 11 IWN�--}� 13A-0dbs 2 glazing-cfr,lox-e_ 13A-4= 2 glazinq. clr lox_e 13A4ocs - i2glazing,.dnlax-e--0.650_.e--18.20-33.77_-0--0 13A-4ccs 2 glazing, clr low' 13A-4oca. ` 12 glazing, Ur-lox;e_ 13AAccs 2 glazinq, clr low eT 13AA=- 2 glazing,. clnloxc 13A-4ocs 2glazinq, Urlave .18X30vOttl 22A-tph ____ '-'0343 __-0.650 0.143 0.650 --0.143 0.143 0.650 _ -0_143 _„-_0.650 0.143 0.650 -0.143 -0.650 0.143 -_0.&% 0.408 _ 1.358 n. _ n_ ne ne a se se ^s _s_ sw sw 'w _w_ rwa nw - = 4A0 _1820 4.00 18.20 4.00 4.00 18.20 _. 4.00 _18.20 4.00 18.20 - .00 4 ----18.20 0.00 0.00 _-1.18 38.02 -2.18 0'----0'u"0 0 0 ­0 0 -90 " 72 0 ` 288 328 0 0 --0 ---158 270 0 0 -- 0 I w �--G WI� _ �'--G w LC WN,,! j. -a _._-14.99 219 26.88 -_ 219 219 27.05 -219 __p 0 0 -__-0 0 0 ��_0 0 0 ._.__ --0 0_0-0.,.._._0__0_-0 0 0 -0 .18 0 0 0 0 _-_0 0 0 0 -- -0 0 0 ---0 0 0 __- -0_--0 - 0 0 0 0 0 _ 0 ---0 0 0 --0 0 0 0 _ 0 V. 0 __0 0 _0 0 ___0 0 0 166 0 0 t-_C IW I '--i W L--G F ^76.03 2-19 -_27.05 219 -33.77 0.00 0.00 0.79 0.00 _-0 0 0 -0 _-._0 0 0 '_�, 48 48 _0 0 0 0 0 -- -0 -0 0 0__ ., 57 0 0 0 _,.,0 0 0 _-0 0 0 .___0 0 0 --0 -0 0 _ 0___ �247, 342 TO -0 0 0 48 0 .-a -0 0 0 __„� 38 0 -0 -_0 0 0 _�__210 210'� 0 _0 0 0 ---210 9 _ _ 6 c)AED excursion _44 -156 Envelope loss/gain 57 -6 12DB 438 12 a) Infiftration b) Room ventilatim 0 0 0 0 168 0 48 0 13 Internal gains; Occupants @ 230 Appliances/other 0 0 500 0 0 1250 Subtotal (lines 6 to 13) 57 494 1373 1736 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 32% 30% 0 0 17 73 23 0 0 10 504 151 32% 30% 0 0 2 1439 439 0 0 2 1737 521 521 Total room load Air required (ofm) 97 4 655 28 1815 73 2259 98 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed AF wri9F+tsoit- 2019-Aug-21 14:28:05 A Right -Suite® Universal 2019 19.0.08 RSU08101 Page 7 ...Wdghtsoft WACINOEL RESIDENCE WITH ICYNENE.rup Calc = MJB Front Doorfaces: E +� wrightsoft Right-M) Worksheet Job: AHU 1 Date: AUGUST 21, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772.466.6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Famed wall Room height Room dimensions Room area RATH 2 0 It 10.0 It heat/cool 6.0 x 7.0 It 42.0 W BEDROOM 3 15.0 ft 10.0 It heat/cool 15.0 x 15.0 ft 225.0 ft' Ty Constmctim number U-velue (BtuWft''F) Or HTM (Btuh/ft� Area (ft0 or perimeter (ft) Load (Btuh) Arm M or perimeter (ft) Load (Btuh) Heal I Cool Gross NIP/S Heat Cad Gross NIP/S Heat Cool 6 1 i sW, L-_G. I w - _--G W"' _L--G W L-G l?1 'r L1i 19A-0acs _--� 2glazing„dr law-e_ 1344aca 2 plazinq, dr m-e 13A-0acs - 2 glazing,.d A.-e__ 13A4ocs 2 glazing, dr Iowa 1a4P&a " ' 2 glazing, Gr.lowce_- 13A4acs 2 dazina,dr Iwtie _ 13AAocs 2 glazing,.clr.lbw-e_- 13A4acs 2glazing, clr lowe _ M30{)td- YLMph ,0.143 _. 0.650 0.143 0.650 +-0.143 __ 0.650 0.143 0.650 n �.n- ne ne_ -- a _.e- se se 4A0 '_18.20 4.00 _18.20 4.00 -_18.20 4.00 1820 4.00 _ 18.20 4.00 _ 18,20 - 4.00 :__..18,20 0.00 0.00 =1.18 38.02 -21g _14.99 219 26.88 - 219 __33.77 219 27.05 2.19 .--0 „______0 0 0 __..._ 0 _ 0 0 ---- 0 -_0 0 0 0 0 `-o __-0 0 0 ___0 --0,.-_0 _0 0 0 __o 0 0 0 __ -0 ___0 0 0 ---0 -__0 0 0 -33 0 _,_0 __-_0 0 0 __ _O 0 0 0 --0 _--_o 0 _---0 0 ___0 ____0 0 0 0 0 _.._.-o --0 0 0 ..�__ a 0 0 -_0 ^0 0 0 ____0 ..�__._.o -0 0 0 __ _�..,0 -0 ____0 0 0 _____o .-._ 0.143 _0.650 0,143 __0.650 0.143 ___0.650._w_ 0.143 _�0.650 _0:408 1.358 s s_ sw sw_ w nw nw =. --'o o ._,0 0 0 --0 ______0 0 0 - 49 0 lqJ I--G w�-- _L-G w " C=; F _16.03 219 27.05 u 219 __33.77 0.00 0.00 =0.79'= 0.00 __0 0 __ 0 -0 __0._.--.0 0 0 42 42 __0 0 0 -._0 0 _ 0 150 -36 0 0 _225 225 -0,---0 0 _ 0 174 __._0 0 0 �_�_225 15 0 0 456 _655 0 0 -285 570 -0 0 0 249 _..__1216 0 0 _178 0 0 0 0 �„s42 0 6 c)AED exursion 44 329 Envelope loss/gain 49 -11 1947 1972 12 a) Infiltration b) Room ventilation 0 0 0 0 279 0 80 0 13 Internal gains: Occuparts Q 230 Appliances/other 0 0 500 0 0 0 Subtotal (lines 6 to 13) 49 489 2227 2052 14 15 Less odeoW lead Less transfer Redistdbulim Subtotal Duct loads 32% 30% 0 0 0 49 16 0 0 0 489 147 32% 30% 0 0 0 2227 711 0 0 0 2052 616 Total room load Air required (am) 1 1 65 3 636 28 2938 118 2668 116 Calculations approved byACCA to meet all requirements of Manual J 8th Ed '�"I'H wr119t+>sofY' 2019-Au9-2114:28:05 'A RESIDENCE lteOWITH Universal 2019 1 Calc RJB Fr1 Page 8 ...Wd9htsofl HVAC1NOEL RESIDENCE WITH ICYNENE.rup CaIc=MJB Front Door faces: E r +I+ wrightsoft Right-M) Worksheet AHU1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466.6796 Emil: OUICKCALCWOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room name Elposed well Room height Room dimensions Room area SINKS 2 0 ft 10.0 It heat/cccl 7.0 x 7.0 R 49.0 ft2 BATH 3 6.0 It 10.0 It healfccol 6.0 x 10.0 ft 60.0 ft2 Ty Construction number U-`slue (Btulffl-F) Or HTM (Btuh/ft2) Arm ffl or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 . 11 V�/ Tr ' 1 13Arlacs --' 2 glazing, Ur low;e 13A4ocs 2 plazinp. Ur loxes 13A4dcs"�-0.143 2 glazing,.Urla __ 13A4ccs 2 glazing, Ur lave 1344s'u _ oc 2 glazing, Ur low:e_ 13A4ocs 2plazinp, Urlov_e_ 13A4abs 2 glazing._ or lows_.'_._ 13A4ccs 20MInq or 1. 16MG.Md__ 22A-tph _`_0:143 0.650 0.143 0.650 --0.650 0.143 0.650 o ,_0.650 0.143 __0_650 0.143 0.650 0.143 T_0.650 -.`0.408 1.358 -r _n_ ne _ne_ a _e_ se se s -s_ sw sw w __w w0.00 nw = - 4.00 ,_18.20 4.00 18.20 4.00 _ -18.20 4.00 _-w 18.20 4A0 "--219 -14.99 219 _ 26,88 219 r .33.77 219 27.05 -'-219 -b _0 0 0 --"'-0 _._p 0 _ 0 f0 .___0 0 ___0 0 0 0 0 0"^0 0 0 -_ �0 0 -v -0 ___0 0 0 �_.0 __0 0 0 -_0 0 _ . W^ . NI/ j �-G w LC 15V i` 0 0 0 0 0 0 --'*-0 -0 0 0 - -0 --0 0 .-.._0 0 _0 0 _ --0 0 -0 0 0 ---0 0 0 '----0 0 0 0 0 0 0 0 0 0 0 --0 - 0 0 -0 -0 0 0 0 t-G wl�r L-G IwI �--G F __18.20 4.00 _ 18.20 4.00 -18.20 0.00 ,1.18 38.02 -16.03 2.19 __27.05 219 _.._.33.7Z 0.00 Q00 _0.79 0.00 __0 0 __0 0 _.0 0 0 ^0 0 _ 0 v0 _ 0 0 0 0 0 __0 0 0 0 0 0 0 __o 0 _ 0 192 _218 0 0 -71. 228 0 __ 0 105 ____405 0 0 _48 0 0 ___0 0 0 �0 ..-0.12 0 0 60 0 0 48 �0 0 0 _=60 6 �._ 49 49 49 0 58 0 _____ 39 0 ��60 60 6 c)AED.111. 44 108 Envelope loss/gain 58 -6 709 666 12 a) Infiltration b) Room ventilation 0 0 0 0 112 0 32 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 500 0 0 0 Subtotal pines 6 to 13) 58 494 821 698 14 15 Less eternal load Less transfer Redistribution Subtotal Duct loads 32% 30% 0 0 9 fib 21 0 0 5 500 150 32% 30% 0 0 0 821 262 0 0 0 698 209 Total room load Air required(cfm) 88 4 650 28 1084 43 9DB 39 Calculations approved byACCA to meet all requirements of Manual J 8th Ed =gs Lft>t ft- 2019-Aug-2114:28:05 Right -Suite® Universal 201919.0.08 RSU08101 Page 9 ...Wrightsoft HVAC\NOEL RESIDENCE WrrH ICVNENE.nup CBIC = MJS Front Door faces: E +� wrightsoft- Right-JO Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area WIC3 0 ft 10.0 It heat/coot 6.0 x 5.0 ft 30.0 W CABANABATH 7.0 ft 10.0 It heat/cool 7.0 x 11.0 ft 77.0 W Ty Constnlction number U-value (BtutVftr-°F) Or HTM (Btuh/N� Area (ft� or perimeter (ft) Load (Btuh) Area (ftj or perimeter (it) Load (Bluh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 Ur! 1344 ' 2 glazing, clr.lov _ 13A-0ocs 2 plaid= clr love 13AAa 2 glazing, Ur Iov-ems_ 13A 4a 2 glazing, Ur lox-e 13A4as ~i 2 glazing-clr.]w -,._ 13A-0ocs 2glazinp ;UrhAuA _ 93A-0acs 2 glazing.clr.low-e- 13A-0acs 2 pladm. cln 1. 6X307Itd '----^ 22A-tph -0..143 --0.650 0.143 0.650 .-'--D143 .--0.650 0.143 0.650 -C14-3 _0.6W 0.143 _0.650 - 0.143 -.-0.650 Q143 0.650 ---0.408 1_358 n -n- ne _ne_ a _e_ se se s- -s_ sw _sw w -w- nw w0.00 =' - 4.00 �18.20 4.00 _18.20 4.00 _-18.20 4.00 18.20 --4-00 _.18.20 4.00 __18.20 4.00 -18.20 DOD _ 1.18 38.02 -219 -_-14.99 219 26.88 - 219 _.33.77 219 27.05 2f9'-- - -16.03 2.19 _27.05 219 -33.77 0.00 0.00 _0.79 0.00 ---- - 0 - ----0 0 0 i--0 --.0 0 0 0 ----0 0 0 '----0 -.0 --0- -_-.-_0 0 0 ---0 0 0 0 ---0 --0 0 a ---.0 -0 a 0 - ---0 _ --_0 -_0 0 0 ---0 0 0 --p 0 a 0 _-0 0 0 0 --0 0 0 ----0 _.0 0 0 0 -_0 0 0 .,1-_G W WVy, `C w I--G T 1 ,r G YrJ --C IWI� - �� . �i 0 0 --0---" -0 0 0 0 _-_0 0 0 ----0 -.-0 0 0 ---0 ^.0 -0 0 0 -"--0 _--0 _.0 0 0 -- -0 ----0 0 0 ' 111 '-0 0 -­0 -''o 0 -0 0 0 --0 0 0__ - 70 -0 0 0_ 51 0 0 0 203 W �--G ,O__I_ F 0 0 --'-30 �30 _--0 0 0 =30 0 __0 0 0 -�35 0 __0 0 0 __24 0 _..-.19 a 0 77 77 0 0 _,77 7 _352 0 0 ---01 256 _-653 0 0 -�61 0 - - - 6 c)AED emursion -43 182 Em,Hope lass/gain 35 -19 912 1OD7 12 a) Infiltration b) Room ventilation 0 0 0 0 130 0 37 0 13 Intemal�garm: Occupants @j 230 Appliances/other 0 0 500 0 0 0 Subtotal (lines 6 to 13) 35 481 1042 1044 14 15 Less edemzl load Less transfer Redistribution Subtotal Duct loads 32% 30% 0 0 0 35 11 0 0 0 481 144 32% 30% 0 0 0 1042 333 0 0 0 104i 313 Total room load Air regwred(cfm) 47 2 625 27 1375 55 1357 59 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrY9�+tsoR- 2019-Aug-21 14:28:05 'A RESIDENCE V41T Universal 201919.0.08 RSU08101 Page 10 ...Wdghlsofl HVAC\NOEL RESIDENCE WITH ICVNENE.rup CaIc=MJB Fronl Ooorfaces: E +� wrightsoft• Right- JO Worksheet AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QLnCKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room name Egiosed wall Room height Room dimensions Room area AHU 2 81.3 It 13.2 ft 908.0 ft2 THEATRE 33.2 ft 13.0 ft heat/cool 1.0 x 281.5 ft 281.5 W Ty Construction number U-value (etuh/ft'*F) Or HTM (Btuh/ft2 Area (11) or perimeter (ft) Load (Etuh) Arm (ftj or perimeter (ft) Load (Btuh) Heat Cod Gross I WP/S Heat cod Gross WP/S Heat Cool 6 11 __..., W, � L-_-_C _ _�.__.,, 13A-0ocs 2 glazing clr Io re_, 13A-4ocs 2 glazing _dr IWte! 13A-4= 2.glazing,.ciclow-e__..._-0.650 13A-4 cs 2 glazing, dr lov-e_ 134-0acs 2 glazing, cU Iowe 13A-4ocs 2 glazing, clr Ioue� 134-0ocs- 2glazing;.dr.1owe- iaktocs 2 glazing, dr lc a ,16X30-0LOW �.� 27A-tph _ -.�_ 0143 _ ,0.650 0.143 0.6W -0,143 0.143 _ Q650 6.143 _-__0.650 0.143 �0.650 o.143'w -0.650 0.143 0.650 . =0 408 1.358 n -n_ re _ne_ a _.e_ se se -s _s_ sw sw _w_'-18.20 mN nw ; --_ _ 400 18.21 4.00 ,_0.00 4.00 _18.20 0.00 ROD -6. DO _0.00 -`2.19 ,_74.93 219 OM_ v219 _33.77 0.00 0.00 -0.00 __0.00 -�370 '.__ 48 55 0 ^ 337 1._...___,36 0 0 ---0 0 _ "-'-322 --.--0 55 0 ��- 1289 ^ 87..4 221 -0-- 1205 _____655 0 0 ____ 0 __0 "�705 �._720 121 0 659 -_1216 0 0__0 i1§0 ___-0 55 _ 0 247 -_0 0 0 '-'130 -,_ 0 55 0 247 _.__0 0 _0 --0 -'! -521� , _.-0 221 0 ---989 --0 0 0 __ 264 _ 0 121 0 ---540 _--_0 0 0 '___ __0 ____O 0 0 __-0 0 0 - � 223 _ _ 0 Iw I--G IW VN �C _ 301 -______0 0 0 --_0 _0 a L _ G t-G W,I Iw L-G ,C.=_ F _ _i_ 0 0-0-0---0 0 0.00 0.00 T4.00_219---285201---805 4.00 0.00 _-_ 1'.:.18 38.02 _ 0.00 0.00 _33.77 2-19 0.00 _0.79 _ 0.00 0 0 -_84 64 0 �,,.� 908 908 0 0 -0 64 0 -908 81 _ .. _ 0 0_ _1529 255 0 y.-1070 3093 0 0 440 _.-2837 139 0 -720 0 0 0 0 0 -__0 0 0 _-282 _ 33 0 0 `0 0 0 � 332 1261 - _ 0--0----6-'-0 --0 0 0 = 282 _ _.. 282 6 c)AED excursion 503 -175 Envelope loss gain 10995 8057 3323 993 12 a) Infiltration b) Room ventilation 2059 0 594 0 805 0 231 0 13 Internal gains: Occupants @ 230 Appliancestother 0 0 1500 0 0 1500 Subtotal ginm 6 to 13) 13064 10151 4128 2724 14 15 Less edema) load Less transfer Redistribution Subtotal Dud loads 17%1 3TI. 1 0 0 0 13064 2179 0 0 0 10151 3078 17% 30% 0 0 456 4584 765 0 0 487 3211 974 Trial room load Air requiretl (rim) 15243 597 13229 597 5349 209 4185 169 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed A&A +�1- =Lq!7tm 2019-Au9-21 14:28:05 Right-SuiteT Universal 2019 1 CaIc RJ8 Fr1 Page 11 ...Wn9htsofl FNAC\NOEL RESIDENCE WITH ICVNEt�.rup Calc=MJB Front Door faces: E + wrightsoft• Right-M Worksheet AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fac 772-466-6796 Email: OUICKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room name E-qosed wall Room height Room dimensions Roomarea GAMEROOM 39.2 It 15.0 ft heat/cool 1.0 x 413.5 It 413.5 ft' HALL 4.0 ft 10.0 ft heat/cool 1.0 x 157.0 it 157.0 W Ty Constmcticn number U-value (BtuWftk'F) Or I HTM (Btuwm Arm (ftj or perimeter (ft) Load (Btuh) Arm or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cod Gross WP/S Heat Cool 6 11 _.._ �., L _.. _ 6F_..�..-,-_ 13A1wcs 2 glazirg, cldw _ 13A4acs 201azinp.dr-' h 13A4dcs 2 glazing,.draowe_- 13A4ocs 2 glazing, dr lc x a 1a4--4- s. 2 glazing„cir law-c__ 13A4acs 2 plazirtp, dr low-e` -13A4ocs� :2 glazing„cicl=v a 13A4acs 2 glazing, clr 1. 16X30-0td� 22A-tph _ 0:143 .V0.650 0.143 _0.650 0.143 _0.650 0.143 0.650 0 w -0.650 0.143 0.650 0.143 -__0.650 Q143 _ �0.650 0.408 _ 1.358 n _in ne _ne a _-a.. as se s _s_ sw sw_ - w _w_: nw my `T 0- �-- 4.(10 _18.20 4.00 +,0.00 4.00 -18.20 0.00 0.00 `-0.00-0.00 -�219 _14.99 219 __0.00 219 -33.77 0.00 0.00 -"240" _ 48 0 0 "-"_-0 _r_.,0 0 0 "-192 __0 0 0 - -0 ........__.0 0 0 �`W`769' --8Z4 0 0 -�� 0 r._ 0._.._-0.__-21 0 0 420 _ -720 0 0 ---0 0 0 "-b - -0 0 0 ---- 40 0 0 -"-"0 _0 0 0 -16 ----0 0 -0 0 0 0 -- _ -.35 --811 0 0 _-_ _.6 - ----6 WI � W - 0 0 64 W LG IlNN T L.- _-0 0 0 �__ _0 0 -437. 0 0 _ _0 0 '- 0 0 -0 0 -_ .,..__.0 ___._D 0 _-_o 0 VN W, I--0 IW L-G .0 r� F _ _O.00 0.00 _� 0.00 4.00 __18.20 4.00 0.00 -1.18 38.02 _0.00 0.00 0.00 ^219 ._..33.77 219 0.00 -6.79 0.00 0 0 0 0 ---201 -0 ._0 0 _ _ 0 805 -1529 0 0 0 0 - -0 0 0 0 ---0 0 0 0 -- -- 0 _0 __O 0 0 - ---0 -.0 285 _...84 64 0 __ 440 ___2837 64 0 __ 414 39 255 0 �= 487 1489 139 0 �328 0 0 0 0 0 _--,�..157 4 0 0 ,._ __185 152 0 0 ! _724 0 414 414 _�t$7 157 _ _ _-_ 6 c)AEDercursian 708 -17 Frnelope loss/gain 6207 5591 838 953 12 a) Infiltration b) Room ventilation 1096 0 315 0 74 0 21 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal ilines 6 to 13) 73D4 59M 912 974 14 15 Less edema] load Less transfer Redistribution Subtotal Dud loads 179/6 30% 0 0 140 7444 1242 0 0 150 6056 1836 17% 30% 0 0 -912 0 0 0 0 -974 0 0 Total morn load Air required (cm)340 8686 7892 356 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -✓f-I�- wrlgF�tsoTt- 2019-Aug-21 14:28:05 RESIDENCE T Universal 2019 1 Cale RSU08101 Page 12 ...Wrightsofl HVAC\NOEL RESIDENCE WITH ICYNEI�.rup Cale = MJB Front Door aces: E / +}►- wrightsofr Right- JO Worksheet AHU2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-4666796 Email: OUICKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room narne E>yosed wall Room height Room dimensions Room area AHU 2 CLST 0 R 10.0 It heat/cool 4.0 x 4.0 ft 16.0 fl' HALF BATH 5.0 It 10.0 R heat/cool 5.0 x 8.0 It 40.0 ft- Ty Construction number U-value (Btuh/ft-F) Or HTM (Btutvfl=) Area M or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heal Cod Gross WP/S Heat Cool Gross WP/S Heat Cool s 11 .U�J ',- - _ -_ 13A-0acs'__�_- 2 glazing, clr,tov;e_ 13A40cs 2 olazing _dr low_e 13A4ocs " 2 glazing,: clr.low-e-_ 13A-0acs 2 glazing, clr Iwte 13A-0ocs 2 glaang,dClov:e- 13A-0acs 2 olazinn, clr lav_e 13Alwcs 2 glazing,.cldoa e- 13A-4ocs 2 glazing, dr love 16X30-Md- - --- 22A-tph__ - ---0.143 0.650 0.143 _,_0.650 - 0.143 _-0.650 0.143 0.650 "ri -n- ne _ne_ a -e_...-18.20 se se - s -'-' _s_ sw sw w .-_w_ nw _ nw 4.-00 �18.20 4.00 _-0.00 4.00 0.00 0.00 Too- -_.-0.00 0.00 0,00_ -4.00 _18.20 4.00 O.DO ,,,_ 1.18 38.02 __'219 ,14.99 219 __0.00 219 _,33.77 0.00 0.00 --o.00 , _0.00 0.00 0.00 -219 -33.77 219 0.00 0.79 0.00 0 =__ __._0 ,.._0 0 0 .,_--__� 0 -_0 0 0 ^.p 0 ---o 0 --_-0 0 _-p 0 0 0 152 -218 0 0 __-.o _LC w .w I 1-ti W aC ,0 0 _ 0 -"0 :.--0 0 0 -_._ _o ___._0 0 0 ��0 _`0 0 0 '=i6 16 0 0 0 _ 0 - 50 --12 0 0 0 0 _0 0 0 -__---83 -__-_405 0 o __o __0 a 0 _._0 0 0 `-32 0 0 -__-0 0 0 - --a -_,0 0 0 -! 0 -0 0 0 0 J.___0 0 0 0 _..__.0 0 0 38 0 0 IlN�J 1' `G _- oia5 -.0.650 0.143 - 0.650 0.143 _0.650 Q143 0.650 =0.408 1.358 .r_ o __0 0 0 -- -0 --0 0 0 __--_o __-0 0 0 -'_--o _ _-_0 0 _0 , 0 -0:-.0 0 0 i40 40 a _-0 0 __0 - 0 0 0 6'- 1qJ w�, IwI �--G C_--, F -0 0 .^_- 0__^-0 0 0 0 0 ::--47, 0 __0 0 0 = 13 0 16 0 40 5 _„19 0 190 6 c)AED excursion -1 -12 Envelope Ims/gain 19 12 608 503 12 a) Infiltration b) Room ventilation 0 0 0 0 93 0 27 0 13 Internal gains: Occupants @ 230 Appliances/olher 0 0 0 0 0 0 Subtotal Qines 6 to 13) 19 12 701 535 14 15 Less wdemal load Less transfer Redistribution Subtotal Duct loads 17% 30% 0 0 -19 0 0 0 0 -12 0 0 17% 30% 0 0 335 1038 173 0 0 349 884 268 Total room load Air required (cfm) 0 0 0 0 1208 47 1152 52 Calculations approved byACCA to meet all requirements of Manual J Sth Ed .ZA wr19�+� �>K 2019-Aug-21 14:28:05 RENCE V41T UICYN al 201919,0.08 RS1108101 Page 13 ...Wrighlsofl HVACINOEL RESIDENCE WITH ICYNENE.rup Calt = MJB Front Doar fates: E +� wrightsoft, Right-JO Worksheet AHU 3 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-468-6799 Fiuc 772466-6796 Email: QUICKCALCS@AOLCOM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room name F)osed wall Room height Room dimensions Room area AHU 3 107.9 1t 10.7 R 924.5 ft2 MASTER BEDROOM 425 It 12.0 ft heat/cool 1.0 x 331.5 It 331.5 ft' Ty Construction number U-value (Btuh/ftz°F) Or HTM (Btuh/ftj Area (fi5 or perimeter (1t) Load (Btuh) Area or perimeter (ft) Load (Btuh) Heat I Cool Gross WP/S Heat Cool Gross WP/S Heat Cod 6 'W_1-13A'-0acs 2 glazing, drIa _ 13A-4ws 2clazino, dr Iov_e '13A4ocs "- 2 glazing,.ciclo __ 13A-4ocs 2 glazing, or Iwte 2 glazing,d1.Icove_ 13A-0a'a 2dazirq, dr lav-e 13A 4acs 2 glazing,.dr.lov-e__ 13A-0acs 2 glazing, dr Iow-e _ ,16X30-Otd„ #A-lph -_0143 _0.650 0.143 0.650 -� 0.143 _-0.650 0.143 0.650 „_0.650 0.143 __.�0.650 0.143 0.650 0.143 0.650 � `0.408 1.358 r _n_ ne ne a _e_ se se s _s_ sw _sw_ w _w_ nor _ m 4.00- _0.00 4.00 _ 18.20 4.00 _._18.20 4.00 18.20 --4.00 4.00-_-219 -18.20 4.00 _18.20 --4.00 . _18.20 4.00 18.20 =1A8 38.02 2.19 -__,_0.00 219 _26.88 219 _33.77.-.___.12 219 27.05 -_16.03 219 27.05 -. 219 _.33.77 219 28.88 �0.79 0.00 64`���64 0 ,_, _ 0 35 __ 0- 158 _.__O 85 0 `--'328 __O 89 0 -._-156 -0 94 _ 0 = �925._,__1089_ 108 �._256' ___0 139 140 833 ____218._._._.405 339 140 �140-24-24 0 76 206 ---346 185 207 0 0 0 -i0 .._.r0 0 96.-­53 0 ___o 0 0 W, �C W L-G W-''--13A-0ocs___-0143 LG 42 _ 8 ' 170 92 8 '---`086 __60 101 12 -174 _____18 136 42 ; _,g25 925 0 0 0 0 -0 __0 - 0 -0 -- --0 -0 0 0 0 0 0 0 0 0 -577, 86 311 _ -144 -608 205 1129 _ 263 0 1305---713 _ __1092 358 209 -- -625 -328 375 764 4103 _ 216 _ _ 180'721_--394 0655 V/J �_C W _� __962 196 311 ~341 __608 205 1129 733 0 __36 51 12 - �84 -_18 136 42 _„__. 332 -332 39 0 -'-66 0 94 _ 0 i 332 43 15S 209 ­ 264 _328 375 764 _391 1616 Iw �-G C _ F 6 c)AED excursion 105 289 Envelope loss/gdn 12114 6869 5577 4059 12 a) In68ration b) Room ventilation 2171 0 623 0 951 0 273 0 13 Intemal gains: Occupants @ 230 Appliances/other 0 0 2500 0 0 1000 Subtotal (lures 6 to 13) 14285 9992 6529 5332 14 15 Less eidernal load Less transfer Redistribution Subtotal Duct leads 16% 329% 0 0 0 14285 2274 0 0 0 9992 3197 160/0 32% 0 0 50 6579 1047 0 0 32 5364 1716 Total morn load Air required (dim) 16559 597 13188 597 7626 275 7080 320 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -1-1i- wr19�+boTi- 2019-Aug-21 14:28:05 A Right -Suite) Universal 2019 19.0.08 RSU08101 Page 14 ...Wdghtsoft HVACINOEL RESIDENCE WITH ICYNENE.wp CaIc=MJ8 Front Doorfaces: E I� +�+ wrightsoft• Right-M) Worksheet AHU 3 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466-6796 Email: OUICKCALCS@AOL.COM Job: Date: AUGUST21,2019 By: 1 2 3 4 5 Room name E:yosed wall Room height Room dimensions Room area M TOILET 0 It 10.0 it heat/occl 6.0 x 4.0 ft 24.0 ft2 M BATH 31.4 It 10.0 It heat(cool 1.0 x 275.0 ft 275.0 W Ty Ccnstruction number U-value (BluIVftk°F) Or HTM (BtulVft2) Area or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat I Cool Gross WP/S Heat Cod Gross N/PIS Heat Cool 8 11 15J 1- 73A-0ocs -'w 2 glazing, cir Iwte, 13A-4ocs 2 gluing_clr IPN6_ 13A4ocs 2 glazing, clrlawe._- 13A 4= 2 glazing, clr lave 13A-4- -- acs 2 glazing,.clrloece_ 13AAocs 2 olazing, cir lav_e-___ 93A4ocs 2 glazing,.dclav e_ 13A4ccs 2 glazing, dr taus 16X30.Otd 22A-tph "�0'143 �0.650 0.143 0.650 -'-0.143 i___0.650 0.143 0.650 ----0.143 _0.6W 0.143 0.650 ....-.-.-0.143.-w_ _-0.650 0.143 0.650 =0:408 L358 n -n_ ne _rte 8 _e . se se_ -s _s_ sw sw _w_ nw _rrx 4A0 -_ 0.00 4.00 18.20 4.00 _18.20 4.00 _ 18.20 4.06 -_18.20 4.00 18.20 -'--4.00 -18.20 4.00 18.20 =1 18 `- 2.19 -_0.00 219 26.88 219 -.-.-.33.77 219 27.05 --'2.19 -�0--�0 0 0 _ 0 "0 __--0 0 0 ---0 0 0 ----0 __0 0 0 4 0 0 42 8 100 ` 40' ,__,;0 35 0 88 _._.__.0 35 0 90 160 __0 139 140 352 __218 139 _ _140 360 86 __ 0 76 206 --- -193 -405 76 _ __207 197 _I-_-G IWI � �_ii_ .W , _'--3 _0 0 00 - --b 0 -0--0 W _ - V1��JJ I !=^- ___.-0 0 0 ----0 _,..-. _-0 0 0 -v--'0 __ -0 0 _ _ 0 -0' _-_72 42 _ 8 90 0 UI! Y-C 'N1/'_� �--G W I--G .F _,: F_ _16.03 219 27.05 _ _' 219.-'-0 -33.77, 219 26.88 =0.78 0.00 ___-_0 0 0 -0 0 0 -` _24 _ 24 __0 0 0 _-_0'--_�0 0 0 0 = 24 _ 0 ,__0 0 0 -_.0 0 0 _ - 8 0 ---0 0 0 __- -0 -0 0 0 _ 19 _ 0 0 0 -0.---0 0 0 --0 -_0 0 0 =275 _31 0 0 --0 __-0 0 0 = 324 _ 1195 0 0 0 -0 0 0 _;218 0 0 -0 0 0 =-275 _275 2 _36_02 6 c)AED emursion _26 -106 Eaelope loss/gain 28 -7 3167 1560 12 a) Infiltration b) Roomw:rdilation 0 0 0 0 586 0 168 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 500 0 0 300 Subtotal (Bares 6 to 13) 28 493 3754 2028 14 15 Less a deale lead Less transfer Redistribution Subtotal Dud loads 16% W. 0 0 0 28 5 0 0 0 493 158 16°/. 32% 0 0 6 3759 598 0 0 4 2031 650 Total room load Air required (cfm) 33 1 651 29 4358 157 2681 121 Calculations approved byACCA to meet all requirements of Manual J 8th Ed A& +� wr1gft> .R- Right -Suite® Unlcars201&Aug-2114:28:05al 2019 19.0.08 RSU08101 Page 15 ... Wnghtsoe WAC1NOELRESIDENCEWITHICYNENE.Np CaIc=MJS Front Doorfaces: E +� wrightsoft* Right-.1® Worksheet AHU 3 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 7724666795 Email: OUCKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room name 5q�osed wall Room height Room dimensions Room area HIS WIC 0 It 10.0 It hwt/cwl 6.0 x 7.0 ft 42.0 ft2 HER WIC 34.0 It 10.0 ft heat/ccol 1.0 x 184.0 R 184.0 ft2 Ty Construction number U-%aloe (Stuh/ft-F) Or HTM (Btuwlt2 Area (ft2) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cod Gross WP/S Heat Cool 6 11 W, 13A 2 glazing, dr lave_ 13A4ocs 2glazinq. clrlave_ 13A-0acs 2 glazing„clWav-e.-.._ 13A-0ocs 2 glazing, or lave 13A-0acs 2 glazin ,dClox-e� g 13A-4ocs 2 glazinq,ylr Ioae� _ 13A4dos 2 glazing,.drlawe_ 13A-4ccs _2 glazing, dr 1. 16)("d_ 22A-tph_ --"0.143 10.650 0.143 0.650 �0.143 ._.__-0.650 0.143 0.650 n _n_ ne no - e _e_ se se 4.00 _0.00 4.00 18.20 4.00 __18.20 4.00 18.20 400 -_._16.20 4.00 18.20 -- -4.00 _._18.20 4.00 18.20 _ 1.18 38.02 "219 __0.00 219 26.88 -- 219 _-33.77.___,_._..0 219 27.05 -fig __16.03 219 27.05 -- 219 __33.77 219 25.88 ®0.79 0.00 --0 ___ 0 0 0 ---0 0 0 '� 0 ..^ _0_0 0 _,« 0 0 _-0 0 0 __ =42 42 0 0 0 0 0 0 --- -0 0 --0 0 --0 _0 0 0 -153 ._._.._0 109 __ 0 -123 _ _385 109 0 197 -0 0 0 -146 0 W L-G IN L--G _0 0 0 ---0 -._-0 0 -i- 0 0 0 0 __0 0 0 0 _-_._._.0 0 _ 0 ` -0 0 0 _ 0 T "0 _.-0 0 0 ' `49 _ 0 0 0 _ 0 --.0 0 _ _0 - 0 0 0 0 0 --70 --0 50 _ 0 - 56 0 50 0 80 0 0 0 _184 34 0 0__ 1--280 --0 200 _ 0 l 224 437- 2D0 0 -70 - --- 0 50 0 8o �24 50 _ 0 90 0 0 "=`134 184 W l �}✓ I. �� U.143 _ �0.650 0.143 _ ,0.65C 0.143 -0.650 0.143 0.650 =0.408 s _ _ s_ sw sw -w _w_ nw m YtJ _ IW r.. _L-G W - F _ __0 0 _0 - 0 --0-0 0 0 -_33 0 --0 ,-_-_0 0 0 42 0 _ 360 -0 0 0 =217, 1.358 1293 6 c)AED excursion -27 -23 Envelope loss/pain 49 7 3212 1199 12 8) Infiftralion b) Room\entilation 0 0 0 0 633 0 182 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 500 0 0 200 Subtotal Qines 6 to 13) 49 507 364E 1581 14 15 Less edema) load Less transfer Redistribution Subtotal Duct loads 16% 32% 0 0 24 74 12 0 0 15 522 167 16% 32% 0 0 0 3845 612 0 0 0 1581 505 Total mom load Air required (dm) 85 3 689 31 4457 161 2087 94 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2019-Aug-21 14:28:05 Right-Suite(i)Universal 2019 19.0.08 RSU08101 Page 16 ...Wdghtsoft H%AC\NOEL RESIDENCE WITH ICVNENE.mp Calc = MJB Front Door faces: E +� wrightsoft, Right-JO Worksheet AHU3 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM Job: Date: AUGUST 21, 2019 By: 1 2 3 4 5 Room narne E1lwsed wall Room height Room dimensions Room area AHU 3 CLST 0 It 10.0 it heat/cool 3.0 x 4.0 ft 12.0 It' M HALL 0 It 10.0 R heat/ccol 14.0 x 4.0 ft 56.0 ft2 Ty Construction number U-value (Btubift-F) Or HTM (Btuhlft� Area or perimeter (ft) Load (Btuh) Area (ft� or perimeter (it) Load (Btuh) Heat Cool Gross NIP/S Heat Cod Gross WP/S Heat Cool 6 11 �J L� 13A400s ._...,.- :2 glazing, driove__ 13 4-0 2 glazirw. dr loxc_ 13A-0ocs -'-0.143 2 gIa ing,.draowa_ 13A 4= 2 glazing, cir low¢ 13A-0ocs 2 glazing,.dr low-e_ laA-4 s 2 glazing, GLlow_e 13A4acs 2 glazing„cl0lowe__ 13A-4ws 2 glazing, dr lowc�___Q650 :16=o tcl-=- 22A_tph ._�0.143 0.650 0.143 0.650 _.-.0.650 0.143 0.650 "- n _n_ ne ne -" e" '_e_ se se 4.00 _0.00 4.00 _J8.20 4.00 .,.._78.20 4.00 18.20 4.00 -18.20 4.00 18.20 4.00 _ 18.20 4.00 18.20 _7a8 38.02 -219 __ 0.00 219 26.88 -' 219 -33.77 2-19 27.05 -2.19 _16.03 219 27.05 219 _.33.77 219 26.88 '"„0.79 (100 ,_..._-.0 ____-0. 0 0 "-0 _-_.0 0 0 7__-0 ,_0 0 0 '-^0 .-.-_0 0 0 - . ;12 12 _--0 0 p _^0 0 0 --0 -_.0 0 0 �.. _--0 _-._0 --0 0 0 _-0 _"_0 0 0 -_'_0 ,__0 0 0 -.._.-0 __0 0 0 --o _.0 0 0 ""'_ _ _0 _ ._ _ 0 0 0 �` - 0 0 0 0 _ _--0 __-__0 0 0 _-"0 - __.0 0 0 "_44 0 W . `W, �G W I--G "15J L-C 0 0 --`0 -0 0 0 __'-.-a ____0 0 _ 0 ��0 ---c 0 0 _ 12 0 .__-_0 0 0 --_-0 0 _..-0 0 0 .-- 0 0 -_.0 0 0 -0'-_0 -_-0-143 s0.650 0.143 0.650 0.143 -0.650 0.143 -0.408 1.358 - s _s_ sw sw w _w_ mN nw __ - M/ ,, __ . W __ 1W L-c F __0 0 0 --0 ___0 0 a __;14 -.0-0-0 0 0 0 0 0 0 ____0 0 0 ,_ 56 0 -0 0 0 0 __.__o 0 0 0.----0 _s0 0 0 -"_ 56 0 ,__0 0 0 w66 0 0'-_56 0 0 0 _T _ 6 c)AED excursion 0 -2 Envelope loss/gain 14 9 66 42 12 a) Khralion b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (fines 6 to 13) 14 9 66 42 14 15 Less elaemal load Less transfer Redistribution Subtotal Dud loads 16% 329/6 0 0 -14 0 0 0 0 -9 0 0 16% 32% 0 0 -W 0 0 0 0 42 0 0 Total room load Air required (cfm) 0 0 0 0 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J Sth Ed - wr19F+isof!- 2019-Aug-21 14:28:05 . A Right -Suite® Universal E.mp 1 Calc MJ8RSUFr1 Page 17 ...Wdghtsoft HVAC\NOEL RESIDENCE WITH ICVNEPIE.rup Catc=MJB Fronl Daor !aces: E Duct System Summary Job: +�- wrightsoft® Date: AUGUST 27, zo1B AHU 1 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM Project Information For. NOEL RESIDENCE, RAPHAELHENRI 12103 RIVERBEND ROAD, PORT ST LUCIE, FL 34984 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1550 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 10.500 in H2O 1.000 in/100ft 1550 cfm 241 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diann (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH2 c 636 3 28 1.000 5.0 OxO VIFx 18.6 115.0 st3 BATH h 1084 43 39 1.000 5.0 OxO VIFx 27.0 115.0 st4 BEDROOM 2 c 2259 73 98 1.000 7.0 Ox0 VIFx 10.5 115.0 st3 BEDROOM h 2938 118 116 1.000 7.0 Ox0 VIFx 19.7 115.0 st4 CABANA BATH o 1357 55 59 1.000 6.0 Ox0 VIFx 65.8 175.0 st8 DINING ROOM c 4058 167 176 1.000 8.0 OxO VIFx 42.0 155.0 st7 FAMILY ROOM h 8619 346 162 1.000 8.0 Ox0 VIFx 22.3 115.0 st4 KITCHEN c 2703 107 118 1.000 7.0 Ox0 VIFx 40.5 155.0 st7 KITCHEN -A c 2703 107 118 1.000 7.0 Ox0 VIFx 15.0 115.0 st3 LAUNDRY ROOM h 3482 140 61 1.000 6.0 Ox0 VIFx 26.4 135.0 st6 LIVING ROOM c 2897 88 126 1.000 7.0 Ox0 VIFx 63.8 175.0 St8 LIVING ROOWA c 2897 88 126 1.000 7.0 OXO VIFx 61.0 175.0 st8 OFFICE h 4569 183 179 1.000 8.0 Ox0 VIFx 66.0 175.0 st8 PANTRY c 655 4 28 1.000 5.0 Ox0 VIFx 43.6 155.0 st7 PRAYER ROOM c 612 1 27 1.000 5.0 OXO VIFx 23.4 135.0 st6 SINKS c 650 4 28 1.000 5.0 Ox0 VIFx 12.4 115.0 st3 WIC c 768 23 33 1.000 5.0 Ox0 VIFx 25.9 135.0 st6 WIG c 625 2 27 1.000 5.0 Ox0 VIFx 26.7 115.0 st4 ,Z�. � wrightsoft• 2019-Aug-21 14:28:08 �A •w�• - ••- Right -Suite® Universal 2019 19.0.08 RSUD8101 Page 1 ...Wrighlsoft HVAC1NOEL RESIDENCE WITH ICYNENE.rup Cale=MJB Front Doorboes: E Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st8 Peak AVF 415 490 1.000 743 11.0 0 x 0 VinlFlx st7 st7 Peak AVF 692 813 1.000 882 13.0 0 x 0 VinlFlx st6 st6 Peak AVF 856 934 1.000 873 14.0 0 x 0 VinlFlx st3 st3 Peak AVF 1041 1205 1.000 863 16.0 0 x 0 VinlFlx st4 Peak AVF 509 345 1.000 933 10.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb3 Ox0 1550 1550 0 0 0 0 Ox 0 VIFx 2 -Fk Wrightsaf - 2019-Aug-2114:28:08 •^v� •••.-+ Right-Sulle® Uniwrsa12019 19.0.08 RSU08101 Page 2 ...WrighlsoR WACINOEL RESIDENCE WITH ICYNENEJup Calc = MJ8 Front Door faces: E + wrightsoft° Duct System Summary AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772A66-6799 Fax 772A66-6796 Emil: OUICKCALCS@AOL.COM ill-roject intormation For. NOEL RESIDENCE, RAPHAEL HENRI 12103 RIVERBEND ROAD, PORT ST LUCIE, FL 34984 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 10.500 in H2O 1.000 in/100ft 597 cfm W45f, Job: Date: AUGUST 21, 2019 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm Supply Branch Detail Table Design Htg CIg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mail Ln (it) Ln (ft) Trunk GAME ROOM c 3946 170 178 1.000 8.0 OxO VIFx 24.4 115.0 st5 GAME ROOM -A c 3946 170 178 1.000 8.0 OxO VIFx 21.6 115.0 St5 HALF BATH c 1152 47 52 1.000 6.0 OxO VIFx 3.0 95.0 THEATRE h 2675 105 94 1.000 7.0 Ox0 VIFx 24.4 115.0 st5 THEATRE -A h 2675 105 94 1.000 7.0 Ox0 VIFx 21.6 115.0 sty Supply Trunk Detail Table Name Trunk Type Htg (cfm) CIg (cfm) Design FR Veloc (fpm) Diam (in) H x W (In) Duct Material Trunk st5 Peak AVF 550 545 1.000 700 12.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size pn) Htg (cfm) CIg (cfm) TEL (it) Design FR Veloc (fpm) Di (in) H x W (in) Stud/Joist Opening (in) Duct Mail I Trunk rb2 Ox0 597 597 0 0 0 0 Ox 0 1 VIFx ti 4 wrightsoft- 2019-Aug-2114:28:08 Sa •_ ^•� +^-+•«+^+ Right -Suite® Universal 2019 19.0.08 RSU08101 Page 3 ...Wrighlsoft WACWOEL RESIDENCE WITH ICYNENE.rup Calc = MJ8 Front Door laces: E `I 9 Duct System Summary Job: wri htsoft® y � Date: AUGUST 21, zots AHU 3 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fe c 772-466-6796 Emit: QUICKCALCS@AOL.COM Project For. NOEL RESIDENCE, RAPHAEL HENRI 12103 RIVERBEND ROAD, PORT ST LUCIE, FL 34984 External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 597 cfm 129 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk HER WIC h 4457 161 94 1.000 7.0 0x0 VIFx 14.5 115.0 st1 wswlc c 689 3 31 1.000 5.0 OxO VIFx 11.5 115.0 st1 M BATH h 4358 157 121 1.000 7.0 Ox0 VIFx 11.5 115.0 st1 M TOILET c 651 1 29 1.000 5.0 0x0 VIFx 9.2 115.0 st1 MASTER BEDROOM c 3540 137 160 1.000 8.0 Ox0 VIFx 10.5 115.0 st2 MASTER BEDROOM -A c 3540 137 160 1.000 8.0 Ox0 VIFx 9.5 115.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 275 320 1.000 725 9.0 0 x 0 VinlFlx st1 Peak AVF 322 277 1.000 729 9.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct I Matl Trunk rb4 Ox0 597 597 0 0 0 0 Ox 0 1 VIFx wrightsoR. 2019-Aug-21 14:28:08 •• ^•- W^-+•«*+ Right -Suite® Uniwmal 201919.0.08 RSU08101 Page 4 '4C40k... Wnghtsoft HVAC\NOEL RESIDENCE WITH ICYNENE.,up Calc=MJ8 Front Doorfaces: E