Loading...
HomeMy WebLinkAboutFIELD - LABORATORY REPORT7 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 UES Project No.: 0310.1700251.0043 Date Typed: February 07, 2019 Construction Materials Testing Services FIELD AND LABORATORY REPORT COVER PAGE Client: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 24 O t30 5286 Oakland Lake Circle Permit #, Ft. Pierce, St. Lucie County, FL SCANNED St tUBy � e coUn fy As requested, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or field inspection services on the above project. Testing results and/or inspection observations are reported on the attached sheets. The contents of this package are summarized below: Scope of Work Work Order No. Date Type of Report 106662-1 1 02/06/2019 In -Place Density Test Report w/Activity Record We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned. MAR 18 `019 ST. Lucie County, Permitting Attachments (1) Sincerely, Universal Engifiearing Sciences, Inc. Certificate of Authorization No `00000549 . ri it 149 Richard E. Hoaglin, P.E. FLORIDA Professional Engineer No. 48796 ICC Email: cbugg@nvrinc.com; rhager@nvrinc.com; sign/seal MAIL to ryan homes at 5369 Oakland Lake, Vero Beach, FL 32966 Revised May 2016 Utsrroject No: 0310.1700261.0043 1_ 1 N I i ? _ , L -� UES DOCS No: t 1 . � UES Report No: 106662-1 ARC 020619 ENGINEERING SCIENCES On -Site Time (hrs): 1.00 Consultants In: Geotechnical Engineering • Environmental Sciences Lab Time (hrs): 0.00 Geophysical Services • Materials Testing • Threshold Inspection Travel Time (hrs): 0.25 Building Code Administration, Compliance Inspection & Plan Review Total Time (hrs): 1.25 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 Activity Record Client: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 24 5286 Oakland Lake Circle Permit #, Ft. Pierce, St. Lucie County, FL Date of Activity: Wednesday, 06 February, 2019 Technician: Cliff Cherrnav As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of earthwork testing for the House pad. While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for House pad. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the project compaction requirements of 95% of the maximum dry density per ASTM D-1557. The Contractor was notified of the test results or a copy was left for their records. UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering -Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 Client: Project: Area Tested: Type of Test: Technician: Requirements In -Place Density Test Report UES Project No: 0310.1700251.0043 UES DOCS No: UES Report No: 106662-1 DT 020619 Ryan Homes 1450 Centrepark Blvd Suite-340 West Palm Beach, FL 33401 Oakland Lake Subdivision Lot 24 5286 Oakland Lake Circle Permit #, Ft. Pierce, St. Lucie County, FL House pad Field: ASTM D-6938 Nuclear Gauge Method Lab: ASTM D1557 Modified Proctor Cliff Cherrnay Date of Test: 02/06/2019 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions only and do not address the condition of the undarlvinn snila helms/ tha taetari rionnc. Test No. Location of Test Range Depth (inch) Proctor (2) Field Dry Density (PCF) .Field Moisture % % Compaction Comments (3) 1 NNV test 0-1 ft 12.00 21180 110.4 10.7 99 A 2 N/E test 0-1 it 12.00 21180 109.7 11.0 98 A 3 S/E test 0-1 ft 12.00 21186 109.5 10.6 98 A 4 1 SNV test 0-1 ft 12.00 21180 110.0 12.0 98 A t rf _ KeT. uatum: u = I op of Final Grade (2) Maximum Optimum Proctor Dry Moisture # Density Content 21180 112.0 11.0 This test was performed without deviation from ASTM procedures. (3) Comments Key A. Compaction meets min. requirements B. Compaction does not meet min. requirements C. Moisture does not meet requirements D. Recompaction required E. Recompacted, Retested, Meets Requirements This report shall not he reproduced, except in full, without the written approval of Universal Engineering Sciences. /fin/-oo70 UNIVERSAL UES Pro UES DO N Evoll 51. 43 PY UES Report No: 106662-1 ARC 020619 ENGINEERING SCIENCES On -Site Time (hrs): 1.00 Consultants In: Geotechnical Engineering • Environmental Sciences Lab Time (hrs): 0.00 Geophysical Services - Materials Testing • Threshold Inspection Travel Time (hrs): 0.25 Building Code Administration, Compliance Inspection & Plan Review Total Time (hrs): 1.25 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 Activity Record SCANNE® Client: Ryan Homes BY 1450 Centrepark Blvd Suite 340 St. Lucie COunty West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 24 5286 Oakland Lake Circle Permit #, Ft. Pierce, St. Lucie County, FL Date of Activity: Wednesday, 06 February, 2019 Technician: Cliff Cherrnay As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of earthwork testing for the House pad. While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for House pad. All,test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the project compaction requirements of 95% of the maximum dry density per ASTM D-1557. The Contractor was notified of the test results or a copy was left for their records. VOR W1 UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 UES Project No: 0310.1700251.0043 UES DOCS No: UES Report No: 106662-1 DT 020619 In -Place Density Test Report Client: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 24 5286 Oakland Lake Circle Permit #, Ft. Pierce, St. Lucie County, FL Area Tested: House pad Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 02/06/2019 Lab: ASTM D1557 Modified Proctor Technician: Cliff Cherrnay Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions oniv and do not address the condition of the underlying soils below the tested depths. Test No. Location of Test Range Depth (inch) Proctor (2) Field Dry Density (PCF) Field Moisture % % Compaction Comments (3) 1 N/Wtest 0-1 ft 12.00 21180 110.4 10.7 99 A 2 N/E test 0-1 ft 12.00 21180 109.7 11.0 98 A 3 S/E test 0-1 it 12.00 21180 109.5 10.6 98 A 4 S/W test 0-1 it 12.00 21180 110.0 12.0 98 A (1) Ref. Datum: 0 = Top of Final Grade (2) Maximum Optimum Proctor Dry Moisture # Density Content 21180 112.0 11.0 This test was performed without deviation from ASTM procedures. (3) Comments Key A. Compaction meets min. requirements B. Compaction does not meet min. requirements C. Moisture does not meet requirements D. Recompaction required E. Recompacted, Retested, Meets Requirements This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences. r� I UNIVERSAL ENGINEERING SCIENCES Consultants In: Geotechnical Engineering• Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 UES Project No.: 0310.1700251.0043 Date Typed: February 07,2019 Construction Materials Testing Services FIELD AND LABORATORY REPORT COVER PAGE Client: Ryan Homes 1450 Centrepark Blvd Suite 340 West Palm Beach, FL 33401 Project: Oakland Lake Subdivision Lot 24 5286 Oakland Lake Circle Permit #, Ft. Pierce, St. Lucie County, FL As requested, Universal Engineering Sciences, Inc. (UES) representative(s) performed construction materials testing and/or field inspection services on the above project. Testing results and/or inspection observations are reported on the attached sheets. The contents of this package are summarized below: Scope of Work Work Order No. I Date Type of Report 106662-1 1 02/06/2019 In -Place Density Test Report w/Activity Record We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned. Attachments (1) Sincerely, Universal Engineering Sciences, Inc. 111ji l l'j l ;g/ Certificate of Authorization No. 00000649 �N\����p5>i� rFlfi�� Richard E. G�:• �c�+vsF��G��% Hoaglin, P.E. 2019.02.07 r40. asy m 96 13:01:32 r ►'. s- A of ' �i= 05'00' Richard E. Hoaglin, P.E. FLORIDA Professional Engineer No. 48796 This item has been electronically signed and sealed by Richard E. Hoaglin, P.E. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. ICC Email: cbugg@nvrinc.ccm; rhager@nvrinc.com; sign/seal MAIL to ryan homes at 5369 Oakland Lake, Vero Beach, FL 32966 Revised May 2015