Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFI'dr Energy Efficiency Cade For �u�IdingFConstruction t-i s Eiorlda 'JeE m nt of 0ornrnunit i Affal�s sr �� Ta.:"v. 36,�'sir& ,�L,� r• M^�J h x1a cy aw n Y r' e*r�2--r. a ',. r ., s m�'m r PROJECT SUMMARY BY St. Lucie County Short Dese: Grace Emmanuel Description: Grace Emmanuel Church Owner: Grace Emmanuel Church Addressl: Kitterm_ an Road City: Port St. Lucie Address2: State: FL Zip: 0 Type: Religious Building Class: New Finished building Jurisdiction: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) Conditioned Area: 13501 SF Conditioned & UnConditioned Area: 13501 SF No of Stories: 1 Area entered from Plans 0 SF Permit No: 0 Max Tonnage 36 If different, write in: EnergyGauge Summit@ FlaICom-2008. Effective: March 1, 2009 11/17/2009 Pagel of 8 Compliance Summary Gross Energy Cost (in $) LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? )esign Criteria Result 19,726.0 24,417.0 PASSED PASSES None Entered PASSES None Entered PASSES None Entered Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this EnergyGauge Summit@ Fla/Com-2008. Effective: March 1, 2009 11/17/2009 Page 2 of 8 1 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Eric J. Svoboda,gPE Building Official: Date: Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (') that the system design is in compliance with the FLorida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Reg No: Plumbing Designer: Reg No: (') Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summit® FlalCom-2008. Effective: March 1, 2009 i ll17/2009 Page 3 of 8 Project: Grace Emmanuel Title: Grace Emmanuel Church --- TYpe:-Religious-Building— -- ---- - ---- (WEA File: FL_ST_LUCIE_CO_INTL.tm3) Building End Uses 1) Proposed 2) Baseline Total 1,309.80 1,929.90 $19,726 $28,726 ELECTRICITY(MBtulkWhl$) 1,309.80 1,929.90 383782 565468 $19,726 $28,726 AREA LIGHTS 261.30 262.90 76561 77041 $3,935 $3,914 MISC EQUIPMT 103.70 103.70 30397 30397 $1,562 $1,544 PUMPS & MISC 0.20 0.10 57 27 $3 $1 SPACE COOL 592.60 846.80 173641 248118 $8,925 $12,604 SPACE HEAT 227.00 141.60 66497 41476 $3,418 $2,107 VENT FANS 125.00 574.80 36629 168409 $1,883 $8,555 Passing requires Proposed Building cost to be at most 85% PASSES of Baseline cost. This Proposed Building is at 68.7% 11/17/2009 EnergyGauge Summit@ FlalCom-2008. Effective: March 1, 2009 Page 4 of 8 External -Lighting -Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (VV) (W) (Sgft or ft) None Project: Grace Emmanuel Title: Grace Emmanuel Church Type: Religious Building (WEA File: FL ST LUCIE CO_INTL.tm3) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance PrOZolSpl 24,001 Worship -Pulpit, Choir 6256 10 3 PASSES PrOZo2Spl 14 Classroom/Lecture Hall 7,245 20 3 PASSES PASSES EnergyGauge Summit@ Fla/Com-200B. Effective: March 1, 2009 I I/17/2009 Page 5 of 8 Project: Grace Emmanuel Title: Grace Emmanuel Church Type:Religious.Building-- — - - (WEA File: FL_ST_LUCIE_CO_INTL.tm3) System Report Compliance PrOSyl System 1 Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 13.00 9.50 9.70 9.70 PASSES 240000 to 760000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 3.50 PASSES System PrOSy2 System 2 Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 13.00 9.70 8.00 PASSES 135000 to 240000 Btu/h Clg Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 3.50 PASSES System PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPLV liance None EnergyGauge Summit@ Fla/Com-2008. Effective: March 1, 2009 11/17/2009 Page 6 of 8 Project: Grace Emmanuel Title: Grace Emmanuel Church Type. —Religious -Building — — -- (WEA File: FL_ST_LUCIE_CO_INTL.tm3) — -- — Water Heater Compliance Description Type Category Design Min Eff Eff Design Max Comp Loss Loss liance Water Heater 1 Electric water heater <= 12 [kW] 0.92 0.86 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] None EnergyGauge Summit@ Fla/Com-2008. Effective: March 1, 2009 11/17/2009 Page 7 of 8 :t: Grace Emmanuel Grace Emmanuel Church File: FL_ST_LUCIE_C0_INTL.tm3) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Report 13-101 Input Report Print -Out from EnergyGauge FlaCom attached ❑ Operations Manual 13-102.1, Operations manual provided to owner El 13-410, 13-413 Windows & Doors 13-406.AB.1.1 Glazed swinging entrance & revolving doors: max. 1.0 cfm/ft'; all El other products: 0.4 cfm/ft' Joints/Cracks 13-406.AB.1.2 To be caulked, gasketed, weather-stripped or otherwise sealed Dropped Ceiling Cavity 13-406.AB.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & side walls System 13-407 HVAC Load sizing has been performed Reheat 13-407.B Electric resistance reheat prohibited HVAC Efficiency 13407, 13408 Minimum efficiences: Cooling Tables 13407.AB.3.2.IA-D; Heating Tables 13407.AB.3.2.113, 13-407.AB.3.2.1D, 13-408.AB.3.2.IE, 13-408.AB.3.2F HVAC Controls 13-407.AB.2 Zone controls prevent reheat (exceptions); simultaneous heating ❑ and cooling in each zone; combined HAC deadband of at least 5°F (exceptions) Ventilation Controls 13-409.AB.3 Motorized dampers reqd, except gravity dampers OK in: 1) exhaust systems and 2) systems with design outside air intake or exhaust capacity<300 cfm ADS 13-410 Duct sizing and Design have been performed ❑ HVAC Ducts 13-410.AB Air ducts, fittings, mechanical equipment & plenum chambers shall ❑ be mechanically attached, sealed, insulated & installed per Sec. 13-410 Air Distribution Systems Balancing 13-410.AB.4 HVAC distribution system(s) tested & balanced. Report in construction documents Piping Insulation 13-41 LAB In accordance with Table 13-41 LAB.2 ❑ Water Heaters 13-412.AB Performance requirements in accordance with Table 13-412.AB.3. Heat trap required Swimming Pools 13-412.AB.2.6 Cover on heated swimming pools: Time switch (exceptions); Readily accessible on/off switch Hot Water Pipe 13-41 LAB.3 Table 1341 LAB.2 for circulating systems, first 8 feet of outlet ❑ Insulation pipe from storage tank and between inlet pipe and heat trap Water Fixtures 13-412.AB.2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public lavatory fixture how water flow 0.5 gpm max; if self -closing valve 0.25 gallon recirculating, 0.5 gallon non recirculating Motors 13-414 Motor efficiency criteria have been met ❑ Lighting Controls 13415.AB Automatic control required for interior lighting in buildings >5,000 El s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or 3 linear fluuorescent lamps>30W 11/17/2009 EnergyGauge Summit@ Fla/Com-2008. Effective: March 1, 2009 Page 8 of 8 EnergyGauge Summit® v3.20 INPUT DATA REPORT Proiect Information Project Name: Grace Emmanuel Orientation: North Project Title: Grace Emmanuel Church Building Type: Religious Building Address: Kitterman Road Building Classification: New Finished building State: FL, No.of Stories: 1 Zip: 0 GrossArea: 13501 SF Owner: Grace Emmanuel Church Zones No Acronym Description Type Area Multiplier Total Area 1sq 1sq 1 PCOZo1 Zone I CONDITIONED 6256.0 1 6256.0 ❑ 2 PrOZo2 Zone 2 CONDITIONED 7245.0 1 7245.0 ❑ 11/17/2009 EnergyGauge Summit® Q.20 1 i Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume Ift] Ift] Ift] plier [sf] [cf] In Zone: PrOZol 1 PrOZo1Spl Zo0Sp1 Worship -Pulpit, Choir 92.00 68.00 16.00 1 6256.0 100096.0 ❑ In Zone: PrOZo2 1 Pr0Zo2Spl ZoOSpI Classroom/LectureHall 63.00 115.00 10.00 1 7245.0 72450.0 Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts i In Zone: Pr0Zo1 In Space: Pr0Zo1Sp1 1 Compact Fluorescent General Lighting l 15000 15000 Manual On/Off 10 In Zone: PrOZo2 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 1 10000 10000 Manual On/Off 20 ❑ Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [it] plier [si] [Btu/hr. sf. F] Capacity [lb/cf] Ih.sf.FBtu] [Btu/sf.F] In Zone: Pr0Zo1 1 PrOZolWal 0.5 Pol/35/8" Mtl 68.00 16.00 1 1088.0 South 0.0423 1.011 8.57 23.7 ❑ std@24"oc/R19/0.5" Gyp 2 PrOZOlWa2 0.5 Pol/35/8" Mtl 92.00 12.00 1 1104.0 East 0.0423 1.011 8.57 23.7 ❑ std@24"oc/R19/0.5" Gyp 11/17/2009 EnergyCauge Summit® v3.20 2 3 MZol Wa3 0.5 Pol/35/8" Mtl 92.00 12.00 1 1104.0 West 0.0423 1.011 8.57 23.7 ❑ std@24"oc/R19/0.5" Gyp In Zone: PrOZo2 1 PrOZo2Wa1 0.5 Pol/35/8" Mtl 115.00 12.00 1 1380.0 North 0.0423 1.011 8.57 23.7 ❑ std@24"oc/R19/0.5" Gyp 2 PrOZo2Wa2 0.5 PoU35/8" Md 48.00 12.00 1 576.0 South 0.0423 1.011 8.57 23.7 ❑ std@24"oc/R19/0.5" Gyp 3 PrOZo2Wa3 0.5 Pol/35/8" Mtl 63.00 12.00 1 756.0 East 0.0423 1.011 8.57 23.7 ❑ std@24"oc/Rl9/0.5" Gyp 4 PrOZo2Wa4 0.5 Pol/35/8" Mtl 63.00 12.00 1 756.0 West 0.0423 1.011 8.57 23.7 ❑ std@24"oc/R19/0.5" Gyp Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/hrsfF] IN [ft[ plier [sf] In Zone: PrOZo2 In Wall: East 1 PrOZo2Wa3Wil UserDefined No 1.2500 0.82 0.76 4.00 5.00 3 60.0 ❑ In Wall: North I PrOZo2WalWil UserDefined No 1.2500 0.82 0.76 4.00 5.00 6 120.0 El In Wall: West 1 PrOZo2Wa4Wi1 UserDefined No 1.2500 0.82 0.76 4.00 5.00 3 60.0 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu] n Zone: PrOZol In Wall: East 1 , PrOZolWa2Drl Solid core flush No 3.00 7.00 2 21.0 0.6061 0.00 0.00 1.65 (1.75") In Wall: West 11/17/2009 EnergyGauge Summit@ v3.20 3 I PrOZoI Wa3Drl Solid core flush No 3.00 7.00 I 21.0 0.6061 0.00 0.00 1.65 ❑ (1.75") In Zone: PrOZo2 In Wall: North 1 PrOZo2WalDrl Solid core flush No 3.00 7.00 4 21.0 0.6061 0.00 0.00 1.65 ❑ (1.75") In Wall: South I PrOZo2Wa2Dr1 Solid core flush No 3.00 7.00 3 21.0 0.6061 0.00 0.00 1.65 ❑ (1.75") In Wall: West 1 PrOZo2Wa4Drl Solid core flush No 3.00 7.00 2 21.0 0.6061 0.00 0.00 1.65 ❑ Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value IN IN plier [sf] [deg] [Btu/hr. St. F] [Btu/sf. F] [lb/cf] [h.sf.FBtu] In Zone: PrOZol 1 PrOZolRfl Mtl Bldg Roof/R-19 68.00 92.00 1 6256.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: PrOZo2 I PrOZo2Rfl Mtl Bldg Roof/R-19 115.00 63.00 1 7245.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] IN IN [Sf] [Sf] In Zone: In Roof: 11/17/2009 EnergyGauge Summit® v3.20 Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. Fl [lb/cf] [hsf.FBtu] In Zone: PrOZol I Pr0Zo1F11 1 ft. soil, concrete 68.00 92.00 1 6256.0 0.2681 34.00 113.33 3.73 floor, carpet and rubber pad In Zone: PrOZo2 I Pr0Z02FlI 1 ft. soil, concrete 115.00 63.00 1 7245.0 0.2681 34.00 113.33 3.73 floor, carpet and rubber pad Systems PrOSyl System 1 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System 432000.00 13.00 9.70 ❑ 2 Heating System 116000.00 1.00 ❑ 3 Air Handling System -Supply 11600.00 0.20 ❑ 4 Air Distribution System 6.00 E3 PrOSy2 System 2 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV I Cooling System 240000.00 13.00 8.00 2 Heating System 136000.00 1.00 3 Air Handling System -Supply 8000.00 0.20 ❑ 4 Air Distribution System 6.00 El 11117/2009 EnergyGauge Summit® v3.20 5 Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description CapacitlCap.Unit I/P Rt. Efficiency Loss 1 Electric water heater 50 [Gal] 12 [kW] 0.9200 [Ef] [Btu/h] ❑ Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Luminaire [sf/ft/No] Control Type Wattage [W] El Piping No Type yp Operating Insulation Temperature Conductivity [Fl [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Thickness [in] Is Runout? ED Fenestration Used Name Glass Type No. of Glass SHGC Panes Conductance [Btu/h.sf.F] VLT ASHULSglClrAII User Defined Frm 1 1.2500 0.8200 0.7600 ❑ 11/17/2009 EnergyGauge Summit@ v3.20 6 i Materials Used Mat No Acronym Description Only R-Value Used RValue Thickness [h.sf.FBtu] [ft] Conductivity [Btu/h.ft.FJ Density [Ib/cfl SpecificHeat [Btu/lb.FJ 187 Mad o . _� . BOARD,1 /2BV 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 218 Mat1218 POLYURETHANE,EXP.,1/2 No 3.2077 0.0417 0.0130 1.50 0.3800 ❑ IN, 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/8IN Constructs Used No Name Simple Construct Massless Conductance Heat Capacity Construct [Btu/h.sf.F] [Btu/sf.F] Density [Ib/cf] RValue [h sf.F/Btu] 1018 0.5 Pol/35/8" Mtl std@24"oc/R19/0.5" Gyp No No 0.04 1.01 8.57 23.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 218 POLYURETHANE,EXP.,1/21N, 0.0417 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ 3 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.000 ❑ 11/17/2009 EnergyGauge Summit® v3.20 7' Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf] [h.sf.FBtu] 1027 Solid core flush (1.75") No Yes 0.61 1.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 278 Solid core flush (1.75") 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf[ [h.sf.F/Btu[ 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cfJ [h.sf.FBtu] 1057 1 ft. soil, concrete floor, carpet and rubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 11/17/2009 EnergyGauge Summit® v3.20 S.