BUILDING SITE PLAN
ServicesStewardship • 7A Mead View Drive Florida License Port Orange, Florida 32127 �Ci• � • 1'� it 1 , John H. VonGunten &Associates 18 LakeviewDrive Florida License #6074 407-321-0933 EMMANUEL Mechanical g inee Eric J. Svoboda, Fort Pierce, Fl. 34950 Florida Re , 09 JI /• 6 Electrical Enginee r Electrical 615 North Peninsula Drive Daytona Beach, od r 3211 Florida Reg. P.E. #33651 • 6 - , ! DrawinQ Index A-0 Cover Sheet. A-1 Floor Plan A-1ALife Safety Plan A-2 Stair, Stage/Platform & Sound Room Plan A-3 Front & Rear Elevations A-4 Side Elevations S-1 Foundation Plan S-2 Foundation Details M-1 Mechanical Schedule & Notes M-2 Sanctuary Modified Mechanical Plan M-3 Mechanical Details E-1 Site Electrical & Lighting Plan E-2 Lighting Plan E-3 Modified Electrical Plan THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY MTN A44APIN WOMW 99glS P!:A).?3 j4V X %Q Sq,w7v �n �/Gl23-a/.5`iO ST. LUCIE COUNTY PLAN REVIEW • E-4 Fire Alarm Plan A �5 0 0�`Q5Q G�����t BN DATE' LD e, �Q() NG'EEC: 24•iI y1 �O p DATE: 3 ' I�X PLUMB: r , I DATE: MECH. DATE.I 11-4-2010 SCANNED BY St. Lucie County REVISIONS — „S-,ZZ -, jJ 39VilO1S m„0-,91 1-----�' 0 9� o o o S 1 v u v L I 8 I 0 �_ Li jS b92"Z I N I Q Z 3SVHd " I Ir N01103S IdN0111a4d l 3SVHd „01-,L „0-s m 10 W O 4 „ 1-,Z ' 0 =N 1 N „9-,ZZ — „9-,{ Z I bo (V N O M Lo W a8-,1 L I W W z 0 � I � z W WhA5321 SNVWOM _,� A 0 W o0 1 a y (] I f „t-,01, W 10 O L� e � z W o v 0 DDDDD- Dz DDDDDDDDD�O DD DzD- ,---DD DDDDDDDDDDDD DD-- DDDi_ DD 1d013S d01aaVHN1313Sd - � 0 00 ITI i L/ Lo N .9-.a O $ '�S49ZZ 0 O N h' F� 110-19L O-,9L - „0-,9L 1.0-191 „0-,SL = 1d101 Z 39dHd 0 3 ro a i S V H z ° r vt O V) gZ 0 N V aZ a0-,OZ .9-'9 ,j FLOOR PLAN 1 /8" = 1'-0" 0 M ORIGINAL BUILDING PERMITTED AND ADDED REVISION: DRIVE THRU 25'x49'4" = 1,233.33 SF MAIN BUILDING 117'x64'8" = 7,566.00 SF SANCTUARY 7O'x69'10" = 4,888.33 SF ORIGINAL TOTAL 13,687.66 SF ADDED BAY 1,629.44 SF EXISTING BUILDING 157317.10 SF ONE BAY 23'4"x69'10" (1,629.44 SF) WAS ADDED TO THE SANCTUARY PRIOR TO THE SLAB INSTALLATION. THE TOTAL BUILDING OCCUPANCY LOAD IS 1,197 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO 114fty WIN A6APPMOMW ##$a O Z_ N O Q ~w0Q \ O Q J J N ryryQ �. C� F— V) N Z Y —� C� zz46 U) zm<:2Q V > oQ�3 LIJ ry SIEWAIRDSIFF SERVICES 937A MEADOW VIEW DRIVE PORT ORANGE, FLORIDA 32127 386-679-0486 FL LIC. # CB-CO59189 Ainlstry in Church Facility Stewardship Q 0 ry 0 0 J of U- z LLI :2 :D ry J F- F- Y F- O UNADIHOMZED ALTERATION OR ADDITION TO THIS DRAWING IS A MOLATION OF FLORIDA STAIUIES. ONLY COPIES MADE FROM THE ORIGINAL OF THIS DRAWING, BEARING AN ORIGINAL EMBOSSED SEAL, SIGNATURE AND DATE SHALL BE CONSIDERED TO BE VAUD COPE DATE 11-4-10 COMM. NO. DRAWN BY J. HILLER SHEET TITLE FLOOR PLAN I BeYaols I ^ I In In In o N .19z'2 g Lu C I Z 3vMid I � F 7 137 f A 138 i 0 N 141 > r µH. 4 F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . �DDDDDDDDD - � SANCTUARY 136 I DD0DDDD0DDDDDDD DDDDDD�D�DDD. T 40 W(I )DLDDX0 1396BT,DDDDD�Q--,D�DDDDD �DDD 1 A- �II� � I I oI o 'ds44'z o Z 3�KHd N °3S 8Z5't7 _ IV10I Z 3SbHd 19 Q H Z 11 w 113 w � H°N 114 115 uO w 116A 116 WOMANS R STRM w N o� ow In In a� 2 0 �Ln Ln r a I7?�u) -W LL 4�2 Q w V >O \ o J �� 0 0 0 0�! -< O1 1 — I ' q Lu 0 F10-211 o " NOil a 117A w 10 1C I 0I IF 00 1o1C a N z o 101 FOYER V) 101B V L >L 0 w - Fa O o O OOE Q w 0z i )U iS E� T � N 12 � N 3 O i 1 N 0 pIr M CN z a 12 26 J V n Liu N c� N Z M LL 128 i v CLtt W w > �a LIFE SAFETY FLOOR PLAN 32 C09` w 30 2.0 0 F 01 EGRESS TABLE --- DOOR NUMBER ALLOWED @ .2- REQUIRED FOR EGRESS 101 360 325 101A 360 325 101B 360 145 101C 360 145 104 180 101 109 360 95 109A 360 308 136A 180 102 136B 180 102 139A 180 5 Note: 1. This table assumes all areas within the building are OCCUPANCY TABLE NOTE: TOTAL OCCUPANCY 1 199 occupied to their maximum. w V O 0 a THESE PLANS AND ALL PROPOSED WORK ARE SUSUECT TO ANY CORRECTIONS REQUIRED SY FIELD INSPECTORS MAY Of NECESSARY INTHAT S RQMPW WITH ALLAPPIdOMW AAOra COP y ROOMN SQUARE FOOT OCCUPANCY FBC 2007 1004.1.2 FUNCTION 101 974 195 5' NET FOYER I05 INC. IN RM. 109 INC. IN RM. 109 LIBRARY 106 INC. IN RM. 109 INC. IN RM, 109 CLASSROOM 107 INC. IN RM. 109 INC. IN RM, 109 CLASSROOM 108 INC. IN RM, 109 INC. IN RM. 109 CLASSROOM 109 1,728 246 7' NET FELLOWSHIP IN 121 1 300 GROSS ELECT. ROOM 112 88 1 300 GROSS MECH. ROOM 114 182 1 300 GROSS STORAGE 115 169 2 200 GROSS SERVERY 116 270 6 50 GROSS RESTROOM 117 240 5 50 GROSS RESTROOM 118 238 12 20 NET CRY ROOM 119 171 2 100 GROSS OFFICE 120 182 2 100 GROSS OFFICE 121 169 2 100 GROSS OFFICE 122 273 3 100 GROSS OFFICE 125 109 1 300 GROSS MECH. ROOM 126 252 12 20 NET CLASSROOM 127 224 11 20 NET NURSERY 131 280 14 20 NET NURSERY 132 247 12 20 NET CLASSROOM 133 285 14 20 NET CLASSROOM 134 72 1 100 GROSS OFFICE 135 81 I 30 —GROSS STORAGE. 136 3,944 1,563 7 NET SANCTUARY 137 247 16 15 NET MUSIC ROOM 138 538 37 15 NET PLATFORM 139 132 2 50 GROSS BAPTISTERY 140 34 1 50 GROSS RESTROOM 201 144 3 MAXIMUM SPECIAL USE SOUND ROOM REVISIONS C t � T SIEWARDSMF SERVICES 937A MEADOW VIEW DRIVE PORT ORANGE, FLORIDA 32127 386-679-0486 FL. LIC. N CB-0059189 Ministry In Church Facility Stewardship a 0 ry 0 p _I z LLJ Q U Of J LIJ� Cn Y F-- Of O UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAPING IS A MOLA11ON OF FLORIDA STATUTES. ONLY COPIES MADE FROM THE ORIGINAL OF THIS DRAPING, BEARING AN ORIGINAL EMBOSSED SEAL, SIGNATURE AND DATE SHALL BE CONSIDERED TO BE VALID CO E! DATE 11-4-2010 COMM. NO DRAWN BY TM SHEET TITLE LIFE SAFETY PLAN SHEET 1. t. ul', N 3 0' SCALE: NTS F)IAf`ACTCD 3/4" PLYWD DECK w/ #12x1-1/2" MTL SCREWS @ 8"o/c /#12x1-1/2" MTL SCREE/ 2x4 20ga C CHAN 2x4 -,i- x #12x2-1/2" TL i 12x4 Cd w /D PLATE \ 16ga STL SADDLE TAPC❑NS \ w/ 4en 5/1rv'�" TYP (U]N) TAPC❑N DETAIL 1 ° DBL 8"X2.5" 16 GA STEEL STUD © 16" O.C. SPACING W/ #10-16 SELF DRILLING SCREWS @ 8"o/c E W S TN111 PLAN/ AND ALL PROPOSED WORK AM11UW1CT TO ANY CORRECTIONS" ANOIRID If RILD INIPLCTORI THAT mjY M ICU MV IN ORDIR TO =I I'�U1Pwvmm " om TYP R oor From in SCALE: N.T.S. • e Section Sound R gym SCALE: 1/8" = 1'-0 p\/dG 1�D// nir\ TYP SECTI❑N 1 FIEF Copy 2'-0" 2'-n" 7'-n" ?'-n" ),-n„ T TT U O N C7 z U. 81 0 Q REVISIONS Z 8IEWAP4M4P SERVICE 937A MEADOW VIEW DRIVE PORT ORANGE, FLORIDA 32127 386-679-006 FL LIC. # CB—CO59189 Ministry in Church Facility Stewardshi UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWNG IS A VIOLATION OF FLORIDA STATUTES 0 COPIES MADE FROM THE ORIGINAL OF THIS DRAW BEARING AN ORIGINAL EMBOSSED SEAL, SIGNATUI AND DATE 9RALL BE CONSIDERED TO BE VALID CC DATE 11-4-2010 Z COMM. NO. N U W DRAWN BY J. HILLER 2 I SHEET TITLE H d METAL FRAMING and STAIR DETAILS SHEET 3/4" 1' -0" PLATFORM PLAN VIEW A-2 1/4"' 1/ -0// PHASE ONE FRONT ELEVATION SCALE: 1/8" = V-0" �� ILL3068 3068 3068 PHASE ONE REAR ELEVATION 3068 3068 PHASE 0-NE SANCTUARY I'tBN:iR ELEV. NTS 2-3068 2-3068 PHASE ONE SANCTUARY INTERIOR ELF-V.-2 N TS TNFBEPIAAs AAE SUgNIECT®� PROPp RBgUIR�p �, f C'4NYCCRREC ONSRK 0 YOENFO�bB �INSORR "�M,�Ay,yary, y�R SAT REVISIONS ®1 ~ �0�p ® ilk JJ SiZRDSW SEFMCES 937A MEADOW VIEW DRIVE PORT ORANGE, FLORIDA 32127 386-679-04B6 FL. LIC. # CB—CO59189 Ministry In Church Facility Steward ':�D o= 0 U z o� J m LLLJ z Q 1 0 I�I 0 n I M �J Q 0 ct O 0 J of Z Li l Q U M Of J H— Cn F— Y I- D_ O n UNAUTHORIZED ALTERATON OR ADDITION TO THIS DRANING IS A MOLATON OF FLORIDA STATUTES ONLY COPIES MADE FROM THE ORIGINAL OF THIS DRAWNG, BEARING AN ORIGINAL EMBOSSED SEAL, SIGNATURE AND DATE SHALL BE CONSIDERED TO BE VAUD ODPIE! DATE 11-4-2010 =Din„n„111111111ar�1 DRAWN BY J. HILLER SHEET TITLE SIDE ELEVATIONS SHEET N TS - - - - - - - - - - - ------ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I I I I I I I q I q I � I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I REVISIONS I I I I I i I i i i I I I I I I I I i I I I I I 3068 3068 I I I . I i I I i I i i i I I I i I I I I I ( I I I i I I I I I 6068 I I I I I ---------------------------------------------- I ;� I I � I � I I t I I B*VAFESHP SERVICES 1 037A MEADOW VIEW DRIVE PORT GRANGE, FLORIDA 32127 I 386-679-0486 FL LIC. N CB—CO59189 Minletry In Church Faclllty Stewar8ahlp I I I I = I U �/ � LL 1 � I � I �u I z F-F-T ':�InF- F-I P-\/ATinNi o W o m 0� I z z LL.i LiI I z Q �� I OS10 WORI( o � ; 1 NS ~ I 'RS NAT Y 10� I TO a I Q49q,�� . o W � a- W f U Q I � I py i I UNAUTHORIZED ALTERATION OR ADN110N TO THIS DRAWING IS A VDLAOON OF FLORIDA SIA1M6 ML NPR MADE FRUA ME ORIGINAL OF MIS DRAWW SEARING AN ORIRINAL ENB0sSEED WAL SMAMRE AND DATE SHAL. BE ODNSDIXD TO BE VALID CORE DATE 11-4-2010 I COMM. NO. I DRAWN BY J. HILLER SHEET TITLE I I SIDE ELEVATIONS I I SHEET I 3068 A-- 4 I RIGHT SIDE ELEVATION SCALE 1/8" = 1'-0" I i I - - - - - - - - - - ------------------------------------------------------------------- CI I i a 2 I d � w I I 64'-8" FOUNDATION PLAN SCALE; 1 /8" = V-0" VIA O O Co I FIN.GR 8 99 REVISIONS 1-1-2007 ADDED ONE CONCRETE NOTES, COL. LINE 1. ALL CONC. SHALL HAVE A MIN COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS 2. ALL FOOTING DOWEL BARS SHALL HAVE A STANDARD 90 DEGREE HOOK AND SHALL BE EMBEDDED 5" INTO INTERIOR FOOTINGS AND A MINUM OF 6" INTO ALL OTHERS . 3. WELDED WIRE FABRIC SHALL CONFORM REVISIONS TO A-185. eo 4. PER -TREAT UNDER SLAB AS PER 2001 FLA BUILDING CODE. N 5. A VAPOR BARRIER OF 6 MILL POLY WITH TAPED JOINTS LAPPED 6" MIN.. 6. PROVIDE SPACERS ,CHAIRS, ETC. TO SUPPORT ALL STEEL REINFORCING 7. PROVIDE CORNER BARS FOR ALL 90 DEGREE BENDS. C? 8. ALL REINFORCING STEEL SHALL BE NEW j DOMESTIC DEFORMED BARS GRADE 60 Z PER ASTM A-615 . ALL LAPS TO BE MIN. OF 48 TIMES BAR DIAMETER. 9. ALL REINFORCING DETAILS TO CONFORM TO "MANUAL OF STD. S1EWARDSHiP SF_FMCES 937A MEADOW VIEW DRIVE PRACTICE FOR DETAILING REINFORCING PORT ORANGE. FLORIDA 32127 CONCRETE STRUCTURES , ACI 315" FL. ucfi p CB ° 059189 UNLESS OTHERWISE DETAILED ON Ministry In Church Facility Stewardship STRUCTURAL DRAWINGS. 10. ALL LUMBER IN PERMANENT CONTACT WITH MASONARY OR CEMENT SHALL BE PRESSURE TREATED. 11, FOUNDATION DESIGN IS BASED ON 2000# SF.BEARING AT 2'-0" TEST SOIL PRIOR TO FORMING TO U INSURE STABILITY. 12, PLUMBING WASTE PIPE PENETRATING FOOTINGS SHALL BE C.I. OR SCH 40 PVC O = 13. NON STRUCTURAL CONCRETE REINF. LLU SHALL BE 6x6 w2.9xw2.9 WWF OR WWM O OR STELTH FIBERMESH POLYPROPYLENE z Q FIBERS TO BE APPLIED AT A C) —I 0 MIN OF 2#/CU.YD. W 0 m � afLL z Lii W Q0 z Q oo�_j Lil to W Y � Ah 1PLANO 0 VgjE,s4ACLpRD�0-LL0- MQAYQV�IRf6eYrF/rEp,N SpDRAifTDDSfODNSWo�O Raft_rESSMYN 070877IAT LLI Q C� F UNAUTHORIZED ALTERATION OR ADWTON TO THIS ORAMNG IS A VIOLATION OF FLOMDA STATUTES ONLY COPIES MADE FROM THE ORIGINAL OF THIS DRABW BEARING AN ORIGINAL EMBOSSED SEAL, SIGNATURE AND DATE SHALL BE CONSIDERED TO BE VAUD CORE DATE 11-4-2010 TYP STEP SLOPED FF VAPOR BARRIER (1) #5 CONT. 3" MIN. COV 1 '� PORTOCHERE SLAB COMM. NO. DRAWN BY J. HILLER SHEET TITLE FOUNDATION PLAN SHEET SCALE: 1 /'2" = 1'0" BUILDING UNE— 3" PROJECTION / — 6x6 W.W.M. OR FIBERMESH BUILDING LINE 3" PROJECTION 6x6 W.W.I"l. OR FIBFRI�=SH BUILDING. LINE 6x6 W.W.M, OR FIBERMESH -� 31, PROJECTION (6) #5 BARS EACH WAY - (6) #5 BARS EACH WAY : � � „ a ,..: AY :, � �, (4)#6 BARS EACHW @ TOP &BOTTOM o @ TOP - TOP • @TOP &BOTTOM o =1 t ,,t4 ... .. _.. ��a�. .. .... e —� —a-g 3" MIN. TYP. 3 MIN. TYP. ®. 13" MIN. TYP. 4 —U" I 6x6 W.W.M. OR FIBERMESH 2:7- 4 • #5 MAT TOP & BOTTOM FOOTING A 4"x4"x3< INTERIOR COLUMN 6" PIA. PIPE (4) #5 BARS EACH WAY @TOP & BOTTOM (4) #5 BARS EACH WAY ci @TOP & BOTTOM I x 1�9O�oonm 0* o a ED 4'-0" 0 I SCALE: 1/2" = I'-0" #5 MAT TOP & BOTTOM ROOTING A 4'x4'x3' (4) #5 BARS EACH WAY TOP & BOTTOM ,I 6x6 W.W.M. OR FIBERMESH n (4) #5 BARS EACH WAY TOP & BOTTOM -5Q [End C omn GPooTaRg 3,urn SCALE: 1/2" = I' =0" Footing � C gal Main Frame o0 SCALE: 1/2" = 1'-0" 9vA w w M (00 FIBERMESH 6 MIL. POLY TYP. W/TAPED EDGES & LAPS )NT. W/#3 TIES @32" O.C. `TwpagA0 a� Rkh SCALE: 1/2" = I'-0" #6 MAT TOP & BOTTOM (ING D x4' T 6x6 W.W.M. OR FIBERMESH 3" MIN.I �- 6 MIL. POLY TYP, 2 0 W/TAPED, EDGES & LAPS TYPICAL (2) #5 BARS CONT. W/ #3 TIES @32" O.C. a r[`�i ice[:; 0CR RaFPrODoM,= MWg)DO5� SCALE: 1/2" = I'-0" REVISIONS OR � � I STEWARDSHIP SERVICES H_, X. N C5—0059184 Mq try n Church Patty 5tevwdshp U D W Q3 m w z Q SCALE: 1/2" = I'-0" w U Q Anchor BOits Building SANCTUARY O ® ® U Type A — 4 ea — #1 311 4" Type B — 4 ea — #3 sUejeoB 3 ANO Type 5 — 4 ea — 3 R QUq 0 y�lO�C0Rgrj WogK YP # MAY EI0 nONS DWANA o AyEaArat OR Nomm ro W Anchor Bolts Building {, 2 ®M� Ncssopp�roTO *A"" 6 AZ%A7 RlW%0MIL.% i.•iY Q .J-J- � � /M ED DATE "U Kr CPCLf�`Rew TO f�VALO� cm. _ 6 iii "ill pr w c N 0 T'? NAr COAL AN �� A<. 4Ayto� MAIN BUILDING DATE 8/24/04 Type —4ea—#I 3" Y 311 Comm,. Type D — 4 ea — #1 3/4" 7/8" Pt Type E — 4 ea — #3 DRAWN BY Type F — 4 eo — #I J. HILLER Type G — 4 ea — #1 ANCH R: BOLT DESIGN STRESSES: sreEr TITLE TENSILE STRESS Fu=56 KSI Anchor Bolts Building # 3 YH` STRESS Fy=36 KSI DFOUNDATION ESIGN TENSILE (0.33 Fu)= FT=lcH KSI DRIVE THRU COMBINED SHEAR AND TENSILE FT=<(25.0-1.5 FT.) CONCRETE STRENGTH 3000 PSI PETALS —4ea— I upy Type [3# °°00000° 13 13 TECHNICAD o a o a 0 0❑ ENGINEERING °❑ a° a 0 0 00 SERVICES 943 South Ridgewood Ave. Daytona Beach, FL 32114 (388) 248-1700 SCALE: 1/6" = I,-0" IS 2 UC N E ilnl,A L NOTES: DUCTWORK SYSTEM SYMBOLS SYMBOL DESCRIPTION ® E SUPPLY AIR DUCT SECTION (UP/DOWN) ® ©j RETURN, OUTDOOR OR EXHAUST AIR DUCT SECTION (UP/DOWN) ® ©j OUTDOOR AIR DUCT SECTION (UP/DOWN) ® ©j EXHAUST AIR DUCT SECTION (UP/DOWN) RETURN, EXHAUST OR TRANSFER AIR FLOW SUPPLY AIR FLOW MD 0-7494vt- MOTORIZED DAMPER VD I MANUAL VOLUME DAMPER FD D -- FIRE DAMPER SD SMOKE DAMPER AD 0 ACCESS DOOR FLEXIBLE DUCT CONNECTION ELBOW WITH TURNING VANES SUPPLY DIFFUSER WITH 4-WAY BLOW SUPPLY DIFFUSER WITH 2-WAY BLOW SUPPLY DIFFUSER WITH QUADRANT BLOCK 1-01 RETURN, TRANSFER OR EXHAUST GRILLE OR REGISTER ® EXHAUST FAN ROUND CEILING DIFFUSER rL LINEAR DIFFUSER CDP-I AIR DEVICE, TYPE AND CAPACITY 100 SQUARE TO ROUND TRANSITION EXISTING DUCTWORK OR EQUIPMENT TO REMAIN EXISTING DUCTWORK OR EQUIPMENT TO BE REMOVED NEW DUCTWORK OR EQUIPMENT OROOF CENTRIFUGAL FAN, EXHAUST OROOF CENTRIFUGAL FAN, SUPPLY Ejf ELECTRIC DUCT HEATER --&- UNDERCUT CONTROL SYMBOLS THERMOSTAT - 5'-0" A.F.F. MOUNTING HEIGHT HUMIDISTAT - 5'-0" A.F.F. MOUNTING HEIGHT �- TEMPERATURE SENSOR �- STATIC PRESSURE SENSOR SQ DUCT SMOKE DETECTOR /VD VOLUME DAMPER /AD AUTO DAMPER HVAC PIPING LEGEND -CWR- CONDENSER WATER RETURN -CWS- CONDENSER WATER SUPPLY -CHWS- CHILLED WATER SUPPLY -CHWR- CHILLED WATER RETURN -HWS- HOT WATER SUPPLY -HWR- HOT WATER RETURN - - - - - REFRIGERANT PIPING CONDENSATE DRAIN FROM COOLING COIL - - DOMESTIC COLD WATER - G GAS PIPING SYMBOL 0 NECK FLEX CFM RANGE FINISH REMARKS CONNECTION 4 WAY BLOW CDP-1 6" 6' 0 - 175 OFF-WHITE O O CDP-2 8" 8" 176 - 300 OFF-WHITE OA OB CDP-3 10" 10" 301 - 500 OFF -"MITE OA OB 2 WAA Y BLLOW CDP-4 12" 12" 501 - 750 OFF-WHITE OA OB CDP-5 14" 14" 751 - 875 OFF-MITEQUADADRANNT BLOCK SCHEDULE FOR 24"X24" CEILING RETURN DIFFUSER SYMBOL 0 NECK FLEX CONNECTION CFM RANGE FINISH REMARKS RD-1 6" 6' 0 - 175 OFF-WHITE OC O RD-2 8" 8' 176 - 300 OFF-WHITE OC RD-3 1 10" 10" 301 - 500 1 OFF-WHITE CO RD-4 12" 12" 501 - 750 OFF-WHITE CO RD-5 14" 14" 751 - 1100 OFF-WHITE OC RD-6 16" 16" 1101 - 1500 OFF-WHITE OC REMARKS: A. ALL SUPPLY DIFFUSERS SHALL BE 4-WAY BLOW UNLESS OTHERWISE SHOWN, METALAIRE 5000 B. DO NOT INSTALL DAMPER IN DIFFUSERS USE DAMPER AT FLEX TAKE -OFF TO BALANCE AIR FLOW C. ALL RETURN DIFFUSERS SHALL BE METALAIRE RH SPLIT SYSTEM EQUIPMENT SCHEDULE AIR HANDLERS DESIGNATION AHU-I AHU 2 AHU-6 AHU-7 MANUFACTURER MODEL YORK ND18000OD6AAAI YORK ND18OCOOD6AAAI TRANE (EXISTING) 2TEC3F36 TRANE (EXISTING) 2TEC3F36 WEIGHT (POUNDS) 715 715 150 150 NOM. TONS 15 15 3 3 SYSTEM CAPACITY (BTU/'HR) TOTAL / SENSIBLE 171,270 / 123,770 171,270 / 123,770 32,610 / 25,920 32,610 / 25,920 TOTAL AIR FLOW (CFM) 4,800 4,800 1,000 1,000 OUTDOOR AIR FLOW (CFM) 900 900 100 103 EXTERNAL STATIC PRESSURE 1.011 1.011 0.811 0.8" COIL EAT'F db/wb COIL LAT'F db/wb 78.6 / 65.5 54.8 / 53.6 78.6 / 65.5 54.8 / 53.6 77.8 / 64.7 54.4 / 54 77.8 ! 64.7 54.4 / 54 FAN MOTOR HP 3 H.P. 3 H.P. 3/4 H.P. 3/4 H.P. HEATER, KW STAGES 12KW / I 12KW / I 5KW / I 5KW / I ELECTRICAL-VOLTS/PHASE/MCA 208 / 3 / 53.7 208 / 3 / 53.7 208 / 1 / -- 208 / I / -- CONDENSING UNITS (R-410A) DESIGNATION CU-1 CU-, CU-6 CU-7 MANUFACTURER MODEL YORK YDI8OCOOA2AAA1 YORK Y`D18OCOOA2AAAI YORK TCGD36S43S1 YORK TCGD36S43S PIPE SIZE, SUCTION/LIQUID, IN. (2) 1 1/8 / 5/8 (2) 1 1/8 / 5/8 3/4 / 3/8 3/4 / 3/8 ELECTRICAL-VOLTS/PHASE/MCA 208-230 / 3 / 64.7 208-230 / 3 / 64.7 208-230 / 3 / 12.3 208-230 / 3 / 12.3 NOTES: I. PAIR YORK CONDENSING UNITS WITH EXISTING TRANE 3 TON AIR HANDLERS. 2. REPLACE EXPANSION VALVE IN TRANE 3 TON AIR HANDLER TO R-410A MODEL. 3. SYSTEMS 18 2 HAVE: DUAL REFRIGERANT CIRCUITS. 4. SYSTEMS 1 81 2 TO HAVE CO2 SENSORS IN OUTDOOR AIR INTAKES. 5. ALL SYSTEMS TO HAVE MOTORIZED DAMPERS IN OUTDOOR AIR INTAKES. 6. ALL SYSTEMS TO COMPLY WITH FLORIDA ENERGY CODE. NOTE: SOME NOTE & SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. (REFRIGERANT PIPING NOTES 1. REFRIGERANT PIPING SHALL BE TYPE "K" SOFT DRAWN COPPER TUBING MATH WROUGHT COPPER SOLDER TYPE FITTINGS SUITABLE FOR CONNECTION WITH SILVER SOLDER. 2. COOLING COIL DRIP PIPING SHALL BE TYPE "M" COPPER OR SCHEDULE 40 PVC. PROVIDE 4" DEEP TRAP. 3. PROVIDE ALL VALVES AND SPECIALTIES AS SHOWN BY THE DETAILS AND AS REQUIRED FOR A COMPLETE OPERATING REFRIGERATION SYSTEM. 4. VALVES AND SPECIALTIES SHALL BE AS FOLLOWS: A. GLOBE VALVES, FORGED BRASS, BACKSEATING TYPE 500 PSI B. CHECK VALVES, FORGED BRASS, 500 PSI C. SOLENOID VALVES, FORGED BRASS, 400 PSI D. REFRIGERANT STRAINERS, BRASS, 350 PSI, 100 MESH STRAINER E. MOISTURE INDICATOR, FORGED BRASS, OPTICAL GLASS, 500 PSI F. FILTER DRYER, STEEL SHELL, REPLACEABLE FILTER DRYER 5. REFRIGERANT PIPING JOINTS: ALL JOINTS SHALL BE MADE WITH SILVER SOLDER. THE PIPING SHALL BE CHARGED WTH DRY NITROGEN WHILE CONSTRUCTING THE JOINTS. A REMOVABLE TYPE DRYER STRAINER SHALL BE INSTALLED IN THE LIQUID LINE. A THREE WAY VALVE BY-PASS SHALL BE PROVIDED FOR THE STRAINER, AFTER THE REFRIGERANT PIPING HAS BEEN COMPLETED, THE REFRIGERANT SYSTEM SHALL BE PRESSURE TESTED WITH NITROGEN AT A PRESSURE OF 300 PSI (HIGH SIDE) AND 150 PSI (LOW SIDE). WHILE THE SYSTEM IS BEING PRESSURE VESTED, AN ELECTRONIC LEAK DETECTOR SHALL BE USED TO CHECK FOR LEAKS. PRESSURE SHALL BE MAINTAINED ON THE SYSTEM FOR A MINIMUM OF 12 HOURS. THE SYSTEM SHALL THEN BE EVACUATED TO 2.0 MM MERCURY AND THEN CHARGED AND MADE READY FOR INSULATION. 6. PIPING EXPANSION AND VIBRATION ELIMINATION: PROVIDE REFRIGERANT TYPE FLEXIBLE CONNECTIONS AT THE AIR HANDLER AND AT THE CONDENSING UNIT. THE CONNECTORS SHALL BE AT LEAST 12" IN LENGTH AND SHALL BE LOCATED TO EFFECTIVELY CONTROL VIBRATION AND TO ALLOW FOR CHANGES IN PIPE LENGTH. PIPE INSULATION NOTES 1. THE REFRIGERANT SUCTION LINES SHALL BE INSULATED WITH 1" THICK 'ARMOFLEX", OR EQUAL THE SUCTION LINE SHALL BE INSULATED IN ITS ENTIRETY INCLUDING VALVES AND SPECIALTIES. VALVES AND SPECIALTIES THAT REQUIRE ACCESS SHALL HAVE SPECIAL REMOVABLE COVERS. 2. ALL INSULATION SHALL BE VAPOR SEALED AND BUTT JOINTS OF 'ARMOFLEX' SHALL BE TAPED TO PREVENT INTRUSION AT THE JOINT. 3. SADDLES SHALL BE USED AT ALL PIPE HANGERS TO PREVENT COMPRESSION OF THE INSULATION. ELECTRICAL CONNECTION NOTES 1. COORDINATE POWER WIRING AND CONDUIT FROM PANEL THRU FUSED DISCONNECT TO UNIT WITH ELECTRICAL 2. COORDINATE THE FUSED DISCONNECTS WITH MECHANICAL 3. MAKE FINAL CONNECTIONS TO AIR HANDLING UNIT (NTH "GREENFIELD". MAKE FINAL CONNECTION TO CONDENSING UNIT WITH "LIQUIDTITE". FINAL CONNECTIONS SHALL BE A MINIMUM OF 3 FT. 4. ALL WIRING SHALL BE COPPER. SEE ELECTRICAL DRAWNGS FOR MARE SIZE. 5. CONTROL WIRING SHALL BE RUN IN CONDUIT. 6. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR CONTROL WIRING. 7. AIR HANDLING UNIT SHALL BE PROVIDED WITH SINGLE POINT OF ELECTRIC ENTRY. 8. MECHANICAL CONTRACTOR SHALL PROVIDE MOTOR STARTER AND HEATER CONTACTORS IN CONTROL PANEL. EXHAUST FAN SCHEDULE SYMBOL DESCRIPTION GREENHECK SP-B70, 50 CFM W/ BACKDRAFT EF-I DAMPER - CONNECT TO LIGHT SWITCH. 120V-1e, 0.53A * PRIOR TO SUBMITTING A BID, THE CONTRACTOR SHALL VISIT THE JOB SITE TO THOROUGHLY FAMRIARIZE HIMSELF WITH THE EXISTING FIELD CONDITIONS AND PHYSICAL CONSTRAINTS ASSOCIATED WITH THE WORK TO BE ACCOMPUSHED UNDER THIS CONTRACT. * ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS: FLORIDA MECHANICAL CODE 2007 ED, FLORIDA ENERGY CODE, NFPA-90A STANDARDS FOR THE INSTALLATION OF AIRCONDITIONING AND VENTILATING SYSTEMS, SMACNA DUCT CONSTRUCTION STANDARDS, ASHRAE 62-2004 * VERIFY FINAL LOCATIONS FOR ROUGH -INS WITH FIELD MEASUREMENTS AND MATH REQUIREMENTS OF THE ACTUAL EQUIPMENT TO BE INSTALLED. * COORDINATE THE CUTTING AND PATCHING OF BUILDING COMPONENTS TO ACCOMMODATE THE INSTALLATION OF HVAC EQUIPMENT AND MATERIALS. * PROVIDE WEATHER PROTECTION FOR ALL EQUIPMENT AND MATERIALS STORED ON SITE. * VENTILATION DUCTWORK SHALL BE SHEET METAL AND INSTALLED IN ACCORDANCE WITH SMACNA. ALL OTHER DUCTWORK SHALL BE AS SHOWN ON THE PROJECT PLANS. DUCTWORK INSULATION SHALL COMPLY WITH THE FLORIDA ENERGY CODE. * REFER TO ELECTRICAL CEILING GRID LIGHTING PLAN FOR EXACT LOCATION OF AIR DISTRIBUTION DEVICES * PROVIDE ALL DUCT TRANSITIONS REQUIRED TO CONNECT EQUIPMENT SHOWN TO DUCT SYSTEMS. * PROVIDE DUCT MOUNTED SMOKE DETECTORS ON THE SUPPLY OF ALL AIR HANDLING SYSTEMS 2000 CFM AND GREATER. * PROVIDE AIR BALANCE TO QUANTITIES SHOWN ON THE PLANS. PROVIDE ALL VOLUME DAMPERS REQUIRED TO ACCOMPLISH AIR BALANCE. --SUBMIT BALANCE REPORT FOR REVIEW * SYSTEM TEST & BALANCE REPORT TO BE INCLUDED WITH INSTALLATION PROVIDE REPORT TO OWNER AND ENGINEER FOR REVIEW INSTALLATION WILL NOT BE CONSIDERED COMPLETE WITHOUT T&B REPORT FIBRE DUCT INSTALLATION DETAILS z� Fort Pierce Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 DUCT CONSTRUCTION NOTES Phone: 72672-4637 Fax: 772 672-4637 1.0 ALL DUCT WORK, DUCT FITTINGS, DUCT FLEXIBLE CONNECTIONS, AND FLEXIBLE DUCT SHALL BE CONSTRUCTED AND INSTALLED, AS A MINIMUM, IN ACCORDANCE AND WITH THE STANDARDS AND RECOMMENDATIONS OF 'SMACNA" LATEST PUBLICATIONS AND STANDARDS. 2.0 ALL DUCT WORK SHALL BE CONSTRUCTED OF 1-1/2' FIBRE BOARD EXCEPT EXHAUST DUCTS WHICH SHALL BE SHEET METAL FIBRE DUCTS SHALL BE CONSTRUCTED WITH 1-1/2' BOARD WITH ANTI -FUNGAL INTERIOR COATING. 3.0 DUCT HANGERS AND SUPPORTS SHALL COMPLY WITH x 'SMACNA' STANDARDS IN GENERAL, HOWEVER, DUCT U STRAPS SHALL BE USED UP TO 48'IN HORIZONTAL DIMENSION x (OR ROUND). DUCTS GREATER THAN 48" SHALL BE u IL SUPPORTED WITH TRAPEZE HANGERS AND STEEL RODS. w a Ii a 05 4.0 ALL DUCTS SHALL BE OF THE SIZE AND SHAPE AS SHOWN z BY CONTRACT DOCUMENTS a N � lL 5.0 ALL FLEXIBLE DUCTS SHALL COMPLY WITH UL 181. FLEX w LLJ DUCTS SHALL NOT BE GREATER IN LENGTH THAN 10'. WHERE o LENGTHS GREATER THAN 10' ARE SHOWN ON THE PLANS o Y INSTALL ROUND SHEET METAL TO WITHIN 10' OF THE DEVICE BEING SERVED. 6.0 SHEET METAL TURNING VANES SHALL BE PROVIDED IN ALL SUPPLY AND RETURN RECTANGULAR DUCT WITH ANGLES GREATER THAN 30DEG . 7.0 DUCTWORK PENETRATING FIRE RATED WALLS SHALL BE U EQUIPPED WITH FIRE DAMPERS. NO OPENINGS WITHIN 5' ON EITHER SIDE OF THE FIRE RATED WALL DUCTWORK ON EACH x SIDE OF A FIRE RATED WALL (5) SHALL BE A MINIMUM OF 26 U GA. SHEET METAL. 8.0 ALL DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS W z r818E p4NS LL ¢ z DUCT INSULATION NOTES QU18 6, r70 AU RopOs� � a 1.0 ALL INSULATION SHALL COMPLY WITH THE "RORIDA"Al NaSE�INSpCTf01I0 a J ENERGY CODE' LATEST EDITION. M'IY ARY1NOpp OR6 , U < N Na Eq r0 ¢ w 2.0 FLEXIBLE DUCTS SHALL BE OF THE LOW PRESSURE FACTORY o o 1Ow FABRICATED TYPE CONSISTING OF A ZINC COATED SPRING a Y 0 STEEL HELIX NON-PEFORATED INNER LINING AND 1-1/2" THICK FIBERGLASS INSULATION WITH METALIZED MYLAR ENIGIRqRR..SEAL VAPOR BARRIER. 3 gV a a 3.0 ALL INSULATION SHALL HAVE A MINIMUM FLAME SPREAD/ « SMOKE DEVELOPED RATING OF 25/50 St; 09 ti* 4.0 DUCT SUPPORT HANGERS SHALL PASS AROUND THE OUTSIDE OF ; THE INSULATION USING SHIELDS OR SADDLES SO AS NOT TO COMPRESS THE INSULATION MECHANICAL DRAWING INDEX =€NTEHEREIN ARE I`FOR THE F P.NPNSE AND CLIENT 6 FOR PIERCE ENfiNEERNG, INC. F WHICH TI WERE PfdPNED. NEESE 01 IIPROPFR RELLNHO THESE OEIRENTS WITHOff WRITTEN Alff"IEATIIN NO A TATIQI W FORT PIERCE S ENLIKFN014, HALL N: WITIOJT`FLIT" TO THE SANE.R PFB T©M, FOR PIKE ENCIEERING, INC. O RIONS RESERVER SHEET DESCRIPTION ISSUED M-1 HVAC GENERAL NOTES, SYMBOLS & SCHEDULES Yes SHEET TITLE HVAC GENEERAL M-2 MECHANICAL HVAC PLAN Yes M-3 MECHANICAL HVAC DETAILS Yes NOTES, SYMBOLS & SCHEDULES 11-18-2009 DRAWN: EJS APPROVED: EJS DRAWING NUMBER -1 SHEET I OF 3 09029-01 100 CFM OUTSIDE AIR /_1OX20 1OX20 100 CFM OUTSIDE AIR :I):VZfT 14N0�900 CFM OUTSIDE AIR FIRE SPRKLR VALVE ROOM S�LZ H Z2 a U ALUMINUM HOOD WITH STROOM-0— 20 20X10 DOWN 20X10 DOWN SCREEN. (TYPICAL) + 1 BAPTIS AL RG HIGH IN WALL 14X14 �14X14 M 20X10 BELOW PLATFORM 17 1 G PLATFORM 0 100 CFM BAPTISTRY 7 e / BCD UJ�J 800 230 CFM r230OF 1202 REG 8'0 TYP OF 3 CONFERENCE RM NURSERY ®BATHRM CLOSET CLOSET TODDLER HALLWAY J c70 CIDD DC7a DaD Da0 300 CFM CDP-3 10'0 BATHRM JANITOR SECRETARY OFFICE PASTORS OFFICE RECEPTION HALLWAY 9'-0' AFF OFFICE STORAGE YOUTH YOUTH FL,4N - S/4NCTUARY SCALE I/8" = I'-O" N CEILING HGT 2'-O' AFF. SANCTUARY 464 SEATS 200 CFM 200 CFM CDP-2 CDP-2 8*0 FOYER C FOYER PORTE'COCHERE MEN5 RESTRM RG 300 CFM CDP-3 1(r0 UP t 14X1 p 100 CFM 12x8CD 8*0 TYP IC R�� 00 L 00a aaa 000 aaa aaa as 000 00a aaa 00� aaa ® Coo 48x30 R.G. HIGH IN WALL STORAGE WOMANS RESTRM SERVING KITCHEN FELLOWSHIP, CLASSROOMS CHILDRENS CHURCH, ETC. 900 CFM OUTSIDE AIR FD 1:C11� ELECTRICAL 0 o NOTES: I. FIELD VERIFY EXISTING EQUIPMENT AND DUCTWORK PRIOR TO WORK. INSTALL NEW EQUIPMENT AND DUCTWORK AS INDICATED. EXISTING DUCTWORK TO BE RE -USED WHERE APPROPRIATE. 2. REMOVE EXISTING 10 TON AHU'S I a 2 - STORE ON SITE IN PROTECTED AREA FOR FUTURE USE. 3. ROUTE REFRIGERANT LINES FROM NEW AHU-I a 2 THROUGH WALL TO NEW CU-1 a 2. NOTE - THESE SYSTEMS HAVE DUAL REFRIGERANT CIRCUITS. 4. ROUTE 1 I/4R CONDENSATE DRAIN FROM AHU-I a 2 THROUGH EXTERIOR WALL - TERMINATE ABOVE GROUND IN EXTERIOR LOCATION. 5. INSTALL NEW R-410A COMPATIBLE EXPANSION VALVES IN EXISTING UNBOXED AHU'S 6 a 7 - AHU'S TO BE COUPLED WITH NEW R-410A CONDENSING UNITS. 6. ROUTE REFRIGERANT LINES FROM AHU'S 6 a 7 DOWN IN EXTERIOR WALL TO RESPECTIVE CONDENSING UNITS. 7. ROUTE V CONDENSATE DRAIN DOWN IN EXTERIOR WALL - TERMINATE ABOVE GROUND IN EXTERIOR LOCATION. 8. PROVIDE NEW VENTSTAR T2900 DIGITAL PROGRAMMABLE THERMOSTATS WITH HUMIDITY MODULES a LOCKING COVERS. 9. OUTDOOR AIR INTAKES FOR AHU I a 2 TO HAVE MOTORIZED DAMPER CONTROLLED BY CO-2 SENSOR. DAMPER TO MODULATE BASED ON CO-2 CONCENTRATION. SEE CONTROL DETAIL ON SHEET M-3. DAMPER TO CLOSE WHEN UNIT CYCLES OFF. 10. AHU-6 a 7 TO HAVE MOTORIZED DAMPER IN OUTSIDE AIR INTAKE - OPEN TO SET VOLUME POSITION WHEN UNIT CYCLES ON, CLOSED WHEN UNIT CYCLES OFF. 11. NO FILTERS IN RETURN GRILLS - FILTERS IN UNITS ONLY. KEY NOTES: 0 REMOVE EXISTING 10 TON AIR HANDLER AND REPLACE WITH NEW 15 TON AIR HANDLER AS INDICATED. FIELD VERIFY EXISTING CONDITIONS PRIOR TO INSTALLATION - NEW AIR HANDLER IS LARGER THAN EXISTNG. CONNECT TO EXISTING DUCTWORK. 20 INSTALL NEW UNBOXED 3 TON AIR HANDLER ON MEZZANINE PLATFORM AS INDICATED. REPLACE R-22 EXPANSION VALVE WITH R-410A VALVE. 30 REGISTERS LOCATED IN PLATFORM FLOOR. ® EXISTING DUCTWORK ABOVE CEILING. VERIFY ADEQUATE FLEX DUCT SIZE TO EXISTING DIFFUSERS FOR LISTED AIRFLOWS. 50 INCREASE RETURN REGISTER SIZE TO INDICATED DIMENSIONS. © AIR CONDITIONING SYSTEMS IN THIS AREA ARE EXISTING TO REMAIN. OUTDOOR AIR CALCULATIONS 330 PPL MAX AVG OCCUPANCY x 6 CFM = 1980 CFM O.A. 2000 CFM O.A. PROVIDED. AHU-I = 900 CFM O.A. AHU-2 = 900 CFM O.A. AHU-6 = 100 CFM O.A. AHU-7 = 100 CFM O.A. 7NESBP*' ARESU@✓ ANDACLP @SQUIRED F70ANYCORCPoSEOWOR MAY@ENFC E�INSp RECnONS K ��Ma�rw/Ayroft �SAT .D 1 U 91 004 z Z U1 Ot a 0 Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone:772 672-4636 Fax: 772 672-4637 U a D J W7U LL z o a H, i O U Z J a H W U) W U H ~ �0 U C7 Y d x U �i x U a W W � � Z O J '1 o Q z U a _W 0O Z W O W J Z J a W U ULLJ �N O O LLJ F- � a LL H O Y EL THESE DOCUIXTS, RUNG VRH THE ONCEPTS AHD OR DESM PRESENTED HEREIN ARE DREGED OLT U THE SP MC PHEPDSE INO CLIENT OF FEW PIERCE ENDIAEERDL, He FOR MM THEY ME PREPAP.ER REUSE OR IWROER RET.INEE OR THESE DOWWKS VIROJT WITTEN AOTORIZCTEN AND A TATIOH DY FOR PIERCE VIGEERDHG, DE 9H DE VIHpR LIADRITY TO THE SANE CO YRW0M. FOR PERCE EAMEEZ14 RIG ILL RUMS RESERVER SHEET TITLE HVAC PLAN IJJVG V/iG: 11-18-2009 DRAWN: EJS APPROVED: EJS DRAWING NUMBER M-2 SHEET 2 OF 3 09029-01 1 1/2' STRAPS TO STRUCTURE STAINLESS STEEL BAND II INSULATED FLEX DUCT 3' SHAFT INSERT 1 1/2' INSULATION RADIUS NOT LESS THAN 1 ONDUCT DIA. BRANCH_'Ar7jqjr� - M�/�/ DUCT 7 BUTTERFLY DAMPER OPERATOR ON 1 1/2' STAND-OFF TO ALLOW FOR INSULATION USE ROUND SHEET METAL - DUCT HERE TO LIMIT FLEX DUCT TO 10'-0' IN LENGTH 6'SADDLE - 3' SHAFT INSERT STAINLESS STEEL BAND INSULATE BELLS CEILING CEILING DIFFUSER (TYP.) NOTE: USE BORDER E i WHERE IN HARD CLGS - BORDER TYPE C WHE EXPOSED SECTION VIEW TAKE -OFF FITTING DIRECTION SECURE FLEX DUCT TO TAKE -OFF OF AIR I FITTING WITH STAINLESS STEEL FLOW SCREW DRIVER OPERATED BAND BRANCH FLEXIBLE DUCT DUCT �I II STRAPI_ SADDLE CEILING DIFFUSER. INSULATE BELLS SEE HVAC FLOOR PLAN FOR LOCATION OF DIFFUSER. CEILING I 1/2"x I 1/2"x 12" GALVANIZED ANGLE FASTEN TO SLEEVE (TYP.) HEMMED "S" SLIP BREAKAWAY CONN. (TYP.) INSULATION (SEE SPECS FRAME BRACE 8, CURTAIN FRAME DUCT SIZE AS SHOWN ON PLANS STAINLESS STEEL NEGATOR CLOSURE SPRING GALV. STEEL SLEEVE - GAUGE IN ACCORDANCE WITH SMACNA. FASTEN TO FIRE DAMPER FRAME. GALV. STEEL BLADES W/ INTERLOCKING JOINTS; DROP CURTAIN TYPE WITH 100% FREE AREA (U.L. LABELED) FUSIBLE LINK W.L.) INSULATED ACCESS DOOR ACCESS DOOR MUST BE SIZED AND LOCATED FOR PERSONAL MAINTENANCE ACCESS TO RESET FIRE DAMPER. — BLADE LOCK EXISTING WALL OR CHASE WALL HEATER SECTION I� SUPPLY L AIR COOLING COIL I �I FLEXIBLE CONNECTION GALV. 6" SPRING ISOLATORS (TYP.) COND. DRAIN - SEE PLUMBING TRAP DUCTWORK AND FLEXIBLE CONNECTION AS REQUIRED SEE DRAWINGS. �I-I n II III RETURN II I I AIR— Uu REMOVABLE FILTER AUXILLIARY DRAIN PAN. REFRIG. PIPING. C HORIZONTAL PLATFORM MOUNTED AHU DETAIL - AHU 6 & 7 THREADED CAP WITH %2" 0 THREADED CAP, HOLE DRILLED IN TOP, HAND TIGHTENED. HAND TIGHTENED AIR HANDLER SLOPE TO UNIT DRAIN CO2 SENSOR DRAIN PAN CASING SLEEVE - UNION t N RETURN - OUTDOOR AIR INTAKE MOTORIZED DAMPER fVOLUME —DAMPER 1 i i AHU SUPPLY )L_1 1/2• Z PROVIDE NEW LOW LEAKAGE AUTOMATIC (MOTORIZED) DAMPER IN DUCTWORK TO BE INSULATION NOTE: CONTROLLED AS INDICATED HEREIN. NOTC: USE BORDER TYPE 1 1. FILL TRAP MANUALLY ON INITIAL START-UP. WHERE IN HARD CLGS. - WHEN THE AIR HANDLING UNIT IS DE -ENERGIZED, THE MOTORIZED OUTDOOR DAMPER SHALL BORDER TYPE C WHEN EXPOSED 2. PIPE SIZE SHALL NOT BE LESS THAN DRAIN PAN CONNECTION SIZE. BE CLOSED. WHEN THE AIR HANDLING UNIT STARTS THE DAMPER SHALL MODULATE TO PROVIDE GASKET BETWEEN TAKE OFF 3. A = I2 TIMES FAN SUCTION S.P. CONTROL THE AMOUNT OF OUTDOOR AIR BEING INTRODUCED TO MAINTAIN THE CARBON FITTING AND BRANCH DUCT. B = %" PLUS FAN DISCHARGE S.P. DIOXIDE LEVEL IN THE RETURN AT NO MORE THAN 1000 PPM. WHEN THE UNIT IS OPERATING THE DAMPER SHALL NOT GO FULLY CLOSED BUT SHALL BE OPEN PARTIALLY BRINGING IN A PLAN VIEW 4. ALL CONDENSATE PIPING TO BE PVC. MINIMUM OF 30% OF RESPECTIVE OUTDOOR AIR. 5. INSULATE ALL DRAIN LINES WITH %" ARMAFLEX A FLEX DUCT DETAILS SCA E=(NT.SJ B VERTICAL FIRE DAMPER (LOW PRESSURE) DETAIL SCALe=(NrS, D CONDENSATE DRAIN TRAP DETAIL SCALE=(N.r3, E CO-2 CONTROL FOR OUTDOOR AIR INTAKE SALE=cN.rs, rr16 X 48 BULB r TWX VALVE MOISTURE SIGHT (LASS 1. PROVIDE ACCUMULATOR IF DEVELOPED LENGTH IS GREATER THAN 50' 2. PROVIDE REFRIGERANT PIPE SIZES RECOMMENDED BY MFG. 3. SEE ALSO REFRIGERANT SYSTEM NOTES CHARGE VALVE W/CAP IF NOT PROVIDED WITH UNIT CONDENSING UNIT SEE DETAIL & SCHEDULE BASE FILTER/DRYER — NTH REPLACEABLE CORE ANGLE VALVES y ISOLATION VALVES (TYPICAL) BALL TYPE ISOLATION VALVES IF NOT PROVIDED WITH UNIT iUCTION LINE LIQUID LINE FLEX - DUCT SUPPORT--,, ION ) GAUGE GALVANIZED HP PAN UNDER ENTIRE 1IT W/ MOISTURE SENSOR MECH. ROOM FLOOR TYPICAL AIR COOLED CONDENSING UNIT. DO NOT LOCATE UNIT WHERE THE UPBLAST WILL STRIKE ANY OVERHANG. LOCATE UNIT MINIMUM OF 2'-0" FROM BUILDING EXTERIOR WALL ANCHOR UNIT TO PAD WITH MIN. 1/4' DIA.— EXPANSION BOLTS 0 1 1/2' EMBEDMENT DEPTH & NEOPRENE PAD. (TYPICAL FOR 4) SUCTION & LIQUID REFRIGERANT LINES RUN REFRIGERANT LINES SHORTEST DISTANCE TO BLDG. EXTERIOR WALL SEE PLANS FOR CONTINUATION. PAD TO BE 4' LARGER ALL AROUND THAN UNIT, FURNISHED WITH /4 REBARS AT 6" O.C. BOTH WAYS 8' THICK CONCRETE PAD. 4' ABOVE GRADE AND 4' BELOW GRADE MIN. 3000 PSI lft$0 Aq�'3 SAND MAYNIq pECT F �CpAA�SEDWj Bt BYFI4D NCNS ? IryfiHY/9 qo �'AT FOLDED CROSS B 2' Engineering, Inc. Dependable Mechanical, Electrical & Plumbing Design C.A. No. 28173 315 South 7th Street Fort Pierce, FL. 34950 Phone: 772 672-4636 Fax: 772 672-4637 x U W Z -L LL C 0 o Q / � H aw �� z W of W z J a w U 0,.,/ 0 aF+N X a 0 Ya p•, �SCC T o f Pf) HANGERS: 1. TWIN LOOP CHAIN #I (WORKING LOAD 155 LBS. PROVIDE TW E n¢"S, NINiR nix TM CMCEPtS"M I)OM .4 NOTE: 'S' HOOKS) MMEU MNER W INTENRM MLY HE TM sPFCE C CONDENSATION SENSOR SHALL BE WATER 2. PAN SHALL BE GALVANIZED STEEL %NPRSE " MEff T MT PEKEENMEERM' INC. Ent MNTMY VENE PREPARER. REUSE M ➢PR[PER RnWlfE M a �\ GARD PRIMARY; SECONDARY PART #401480 OR TMSE =a S v1EWT VRMEN MIIIOl UTIDIW RRMTITIM RY MT PIERCE EMilXEERRl6, INC. SIW1 BE DROP IN SENSOR #401485 W/ CONTROL 3. UP TO 4'z 5'-24 GAUGE. union EIRRRm To TM Sac. CMYRENTQM, W BOARD. 24 VOLTS, 40 TO 75 AUDIBLE 4. OVER 4'x 5'-22 GAUGE. PERCE ENRNFFNRlR, M O RIMTS RESER ALARM AND/OR WARNING LIGHT.T. WIRED TO SHEET TITLE SHUT OFF A/C SYSTEM WHEN WATER LEVEL 5. ALL SEAMS SHALL BE SOLDERED. REACHES 1/I6" B ACTIVATES THE ALARM OR WARNING LIGHT. MANUFACTURED BY WATER 6. PROVIDE CROSS BREAK FOR PAN MECHANICAL GARD, INC. 12211 CEDAR, GAP HOUSTON, TX OVER 36' LENGTH OR WIDTH. 77072 888-652-9800 DETAILS ISSUE DATE: 11-18-2009 NOTE: SYSTEMS 18 2 HAVE DUAL 1 REFRIGERANT CIRCUITS. o • PLACE AIR HANDLING UNIT IN THE ROOM SO THAT SERVICE TO ,y DRAWN: SWM THE UNIT & FILTER REPLACEMENT CAN BE ACCOMPLISHED. L APPROVED: EJS DRAWING NUMBER M-3 F REFRIGERANT PIPING SCHEMATIC G VERTICAL TYPE AHU DETAIL - AHU I & 2 H AIR COOLED CONDENSING UNIT DETAIL I EMERGENCY DRIP PAN DETAIL SHEET 3 3 scALc=(N.rs.> scALE=(N.rs.) scacE=(N.rs.) scAl.e=(N.rs.� 09029-0101 3-2" SLEEVE TO CEILING SPACE BELOW TYPICAL I !f COMBINATION LLLVVV... TELEPHONE/DATA ROUGH -IN 3/4" EMT C TO ACCESSIBLE CEILING SPACE 4" SQ. BOX S.G. P.R. NO PLATE 48" x 96" X 3/4" 0 D #6 S LI CU TO MDP TTB � GROUND BUS 2-2"C. TELEPHONE/DATA SCHEMATIC RISER - N.T.S. NOTES 1. COORDINATE INSTALLATION REQUIREMENTS OF JPA UNDERGROUND PRIMARY FROM EXISTING OVERHEAD DISTRIBUTION POLE ON SOUTH SIDE OF NORMANDY BLVD, WITH THAT UTILITY. FIELD VERIFY UNDERGROUND ROADWAY CROSSING LOCATION, ELEVATION, ETC. AND ANY UTILITY REQUIREMENTS ASSOCIATED WITH THAT INSTALLATION. 2. FLP APPROVED C/T ENCLOSURE AND METER CAN. REFER TO SERVICE RISER DIAGRAM SHEET E-4 FOR DETAILS. 3. FURNISH AND INSTALL SERVICE ENTRANCE "SHUNT TRIP" OPERATOR THIS LOCATION, OR AS DIRECTED BY A.H.J. AND WIRE ACCORDING TO SERVICE RISER DIAGRAM SHEET E-3. 4. PROVIDE ONE 3" U/G CONDUIT FOR USE BY SOUTHERN BELL UTILITIES IN COMPLIANCE WITH THEIR SPECIFICATIONS. COORDINATE LOCATIONS WITH UTILITY AND PROVIDE PULL STRINGS. 5. PROVIDE 2 FIXTURES TYPE OB INDICATED TO ILLUMINATE MONUMENT TYPE SIGN THIS LOCATION. CIRCUIT AND SWITCH AS SHOWN. 6. UNDERLINED FIXTURE TYPES INDICATE ON/OFF OPERATION THRU PHOTOCELLS LC1. ALL OTHER FIXTURES TO OPERATE ON PHOTOCELL LC1/ OFF LC2. TIME CLOCK TO BE 24 HOURS , 7—DAY ELECTRONIC TIME WITHIN BATTERY BACKUP WIRE TO SHUT DOWN LC2 ON OPERATION. y 7. PROVIDE ONE 3" U/G CONDUIT FOR USE BY CABLE TV COMPANY IN COMPLIANCE WITH THEIR SPECIFICATIONS. COORDINATE LOCATIONS AN WITH UTILITY AND PROVIDE PULL STRINGS. FINAL LIGHTING 12/1/10 REVISIONS STEWARDSHIP SERVICES P.O. BOX 238662 ALLENDALE, FL. 32123 FL. LIC. # CB—0059189 nistry in Church Facility Stewardship ry 0 Li CD z 0 J m W z W U a a 0 ry 0 p J ry LL_ Z LLJ Q U 120� J LLJ H- ~ H Cn Y G_ O tZ UNAUTHORIZED ALTERATION OR ADDIOON TO THIS DRAWING IS A NOTATION OF FLORIDA STATUTES ONL COPIES MADE FROM THE ORIGINAL OF THIS DRAW BEARING AN ORIGINAL EMBOSSED SEAL. SIGNATURE AND DATE SHALL BE CONSIDERED TO BE VAUD COPII DATE 2/5/03 ��WOg1( 3 COMM. N0. rDRAWN BY J. HILLER SHEET TITLE ELECTRICAL SITE PLAN SHEET E-1 Electrical Symbols DUPLEX WALL OUTLET DUPLEX OUTLET SPLIT WIRED ® SPECIAL WALL OUTLET VENTED EXHAUST FAN (M) STANDARD 220v OUTLET ® DUPLEX OUTLET CEILING MOUNTED wpeFIWEATHERPROOF GROUND FAULT OUTLET wpd WEATHERPROOF OUTLET GFIGROUND FAULT OUTLET W1 SINGLE POLE SWITCH 3 WAY SWITCH 4 WAY SWITCH ❑o DIMMER SWITCH $s SPECIAL PURPOSE SWITCH B� DOOR BELL ® CABLE TELEVISION OUTLET IN INTERCOM INCANDESCENT CEILING FIXTURE RECESSED CEILING FIXTURE INCANDESCENT WALL -MOUNTED FIXTURE ELECTRIC PANELBOARD O JUNCTION BOX 0 WALL SCONCE D OUT DOOR FLOOD LITE TELEPHONE JACK CEILING FAN W/LIGHT FLUORESCENT LIGHT EMERGENCY LIGHT O� 2' x 4' FLUURESCENT CEILING LIGHT SEE FIXTURE SHEDULE FOR MANUFACTURE I.F. IN FLOOR BOX OD M 00 ELECTRICAL DATA PHONE MIC. JACK �V VOLUME CONTROL © COMBINATION TELEPHONE & DATA 8' FLUORESCENT LIGHT SEE FIXTURE SHEDULE FOR MANUFACTURE EXIT EMERGENCY EXIT W/BATTERY BACKUF Lighting Pan SCALE: 1 /8" = 1'—O" 0 . .. °° .0 TECHNICAD ❑o ❑ In In o o 0 ❑ ENGINEERING 0 0 0 ❑ SERVICES 943 South Ridgewood Ave. Daytona Beach, FL 32114 (386) 248-1700 mom 'P" FIXTLRE IS FF AF.O., APnE TYPE "M" FIXTLRZE LP-2I—LOI LP-21—LG2 MOUNT "P" FIXTU2E 15 FT AP6., APOVE TYPE "N" FIXTURE `� LP-21—I LI LP-21—LG2 PANEL 5R 4 PANEL LP LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER CATALOG NO. LAMPS MOUNTING NOTES A METALUX W5-44OAl2OLE 3 4 F40 4—LITE WRAP EQUAL B METALUX 2GC44OA120EB 22 4 F40 4—LITE LAY —IN EQUAL C RUDD ACW499WM WALL FIXTURE D METALUX 2G2U6Al2OLE 3 2 FB40 2x2 LAY —IN EQUAL E RUDD EMWH NONE 2—HEAD EMERGENCY LIGHT E1 RUDD NONE 2—HEAD EMERGENCY LIGHT RECESSED CEILING MOUNT G I PROGRESS P5815-30 1 60—A OUTSIDE BRACKET EQUAL H METALUX LATER 2 F32 4 FT INDUSTRIAL EQUAL K HALO H7 / 300 P 1 75R30 NCD. RECESS CAN TRIM EQUAL L FURNISHED BY WNER 250W FLOOD LIGHT ON TRACK M HALO H274 4051 1 13 UNIT RECESS CAN FLOURESCENT W TRIM EQUAL R RUDD R7M10 1 100 MH RECESS HID T HALO L642P Z L763P 1 75R30 INCD. RECESS CAN TRIM EQUAL 2 CIRCUIT TRACK X1 RUDD EXPB1RWH NONE BATTRY EXIT X1 E RUDD EMXRWH NONE COMBO EXIT & BATTERY EMERGENCY P DAYBRITE NQF-500-120—LP 1-500Q FLOODLIGHT 18' A.F.G. PANEL: LP MFG. SQ. D VOLTAGE 120 240 PHASE 1 WIRE 3 CAT. Q013OL150S AMPS. 150 SYM. A.I.C. (I.E.R.) 22.000* MOUNT SURFACE MAIN M.L.O. GRID. BUS x * SERIES RATING ACCEPTABLE CT DESCRIPTION POLE AMPS WIRE COND 0A OC 1-16 LIGHTS 1 20 #12 1 2" 1719 SITE LIGHTS 1 20 10 3 4" 18 FRONT SIGN 1 20 #10 3 4" 20 SOFFIT LIGHTS 1 20 #10 1 2" 21 PERIM. LIGHTS 1 20 10 1 2" 22-26 SPARES 1 20 27-30 1 PREPAREDSPA CES SWITCHES IN ENTRY/FOYER LC3 LP -NEUTRAL + LP-10 LP-12 LP-14 LP-16 4 DIMMER SWITCHES D D D IN STORAGE ROOM 6 FOYER LIGHTJs 6 FOYER LIGHTS . 6 FOYER LIGH'Tr —� 6 FOYER LIGrITS ENTRY/FOYER LIGHT SWITCHING THE8E p s 088USjECT ANDAILL PgOPOS� p wOR MAY#fN GIUIFiBD8YF1@ CORRW IN,ECnONS K MY444� � RDERTO SAT PAUL M. ESTES, P.E. ELECTRICAL CONSULTANT t15 NORTH PENINSULA DRIVE AYTONA BEACH, FL. 32118 (386)— 252-6948 FL. REG. PE # 33651 �J ,L FINAL DESIGN 12/1/10 REVISIONS S 11WA MHIP SERVICES UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAINNG IS A VIOLATION OF FLORIDA STATUTES 0 COPIES MADE FROM THE ORIGINAL OF THIS DRAIN BEARING AN ORIGINAL EMBOSSED SEAL. SIGNATUI AND DATE SHALL BE CONSIDERED TO BE VALID 00 3/11 /03 COMM. NO. DRAWN BY JMP/PME SHEET TITLE LIGHTING PLA SHEET E-2 Electrical Symbols [� DUPLEX WALL OUTLET DUPLEX OUTLET SPLIT WIRED ® SPECIAL WALL OUTLET ® VENTED EXHAUST FAN STANDARD 220v OUTLET ® DUPLEX OUTLET CEILING MOUNTED QUADRUPLEX OUTLET OUTLET (2)R RANGE OUTLET WP,Ii,OFI WEATHERPROOF GROUND FAULT OUTLET W'd WEATHERPROOF OUTLET GF'd GROUND FAULT OUTLET SINGLE POLE SWITCH 3 WAY SWITCH 4 WAY SWITCH DIMMER SWITCH $s SPECIAL PURPOSE SWITCH B DOOR BELL CABLE TELEVISION OUTLET N INTERCOM INCANDESCENT CEILING FIXTURE RECESSED CEILING FIXTURE INCANDESCENT WALL -MOUNTED FIXTURE ELECTRIC PANELBOARD O JUNCTION BOX 0 WALL SCONCE OUT DOOR FLOOD LITE ,+ TELEPHONE JACK CEILING FAN W/LIGHT FLUORESCENT LIGHT EMERGENCY LIGHT 2' x 4' FLOURESCENT CEILING LIGHT SEE FIXTURE SHEDULE FOR MANUFACTURE I.F. IN FLOOR BOX @MQ(p ELECTRICAL DATA PHONE MIC. JACK �V VOLUME CONTROL © COMBINATION TELEPHONE & DATA 8' FLUORESCENT LIGHT SEE FIXTURE SHEDULE FOR MANUFACTURE EXIT EMERGENCY EXIT W/BATTERY BACKUP A PP2- 11 P 9,11 PP2-• 1,3,5 A-12 CONFERENCE 126 En PP2- 8,10,12 PP2- 14,16,1 PP2A-7 NURSERY 127 BATH 128 PP2A-1 TODDLER Al 131 °° a °°°O° TECHNICAD o ° a ° ❑ ❑ ❑ ENGINEERING ❑ c ° In ° ° 1111 ❑ SERVICES 943 South Ridgewood Ave. Daytona Beach, FL 32114 (386) 248-1700 JANITOR `-�U i 124 123 O PP2A-14 SECRETARY - PP2- 120 13,15,17 / PASTOR'S u OFFICE 12 104 C PP2A-15 PP1-17 PP2A-17 RECEPTION 7 121 PP2A-11 u \ FOYER STORAGE 101 135 PP2A-9 134 OFFICE PP2A-3 / FU VAREE PARTITION PP2A-5 YOUTH YOUTH 132 133 117 MEN'S RESTROOM 61 CLASSROOM 105 CLASSROOM 106 PP1-6 LC1,LC2,TC ACU-6 (MDP-31,33,35) PP1-9 SR-19 MDP-31.: ' .. �. �•7 PY ®PPI-15ftorwJI ELECTRICAL ROOM SCALE: 1/4"=1'—O" SR-21 SOUND ROOM SR-22 37,39,Wfl SR=20 d-lff/ � `-ice 4 PANEL SR SOUND ROOM I SCALE: 1/4"=1'-0" PROVIDE 17 - 1,000 WATT DIMMER SWITCHES WITH/NEAR PANEL SR FOR LIGHTS IN SANCTUARY/STAGE AREA PP1-22 M L ® r AHU AHU L 112 PP1-7,9,11 LP PP1 WP/GFI r� METER & C/T CAN ELECTRICAL MOP 111 SHUNT TRIP J PP1-1,3 LMI PP1-19 KITCHEN 11s HEI PP1-20 RESTROOM P�PP1-2,4F10 CLASSROOM PP1-18 �—1 =i PP1-16 PP1-12 11079 FELLOWSHIP, CLASSROOMS, CHILDRENS CHURCH, ETC. 6— MOVABLE PARTITIONS FUTURE CLASSROOM 107 CLASSROOM 108 PP1-8 PP1-2,4,6 ® PP1-8,10,12 I T1 PP1-14 /GFI PP1-10 PANEL: PP1 MFG. SQ. D VOLTAGE 120 240 PHASE 1 WIRE 3 CAT. Q0142S225L AMPS. 225 SYM; A.I.C. (I.E.R.) 22.000* MOUNT SURFACE MAIN M.L.O. GRID. BUS X * SERIES RATING ACCEPTABLE CT DESCRIPTION POLE AMPS WIRE COND PIA 11fC 1-4 IWARMING OVENE 2 60 #6 3 4" 5-20 OUTLETS 1 20 #12 1 2" 21.23 E.W.H. 2 40 8 3 4" 22 FACP 1 20 #12 1 2" 24 SHUNT TRIP 1 20 #12 1 2 25-34 SPARES 1 20 — — 35-42 PREP RED SP E PANEL: PP2 MFG. SQ. D VOLTAGE 120 240 PHASE 3 WIRE 4 CAT. 00342S225L AMPS. 225 SYM. A.I.C. (I.E.R.) 10,000 MOUNT SURFACE MAIN M.L.O. GRID. BUS X CT DESCRIPTION POLE AMPS WIRE COND ,PIA A OC 1 3 5 AHU-2 3 60 6 3 4" 7 9 11 AHU— 3 30 jyj0 1 2" 131517 AHU— 3 30 10 1 2" 2 4 6 ACU-2 3 70 4 3 4" 81012 ACU— 3 40 8 3 4' 141618 ACU— 3 30 1 #10 1 2" 19.20 SPARES 1#*10 21,27,2 BLANK AHU-7 323 25 PANEL PP2A 229 30 SPARES 131 E,3/ 33 35 ACU-7 332 34 3 SPARES 337-42 PREPARED SP CE PANEL: PP2A MFG. SQ. D VOLTAGE 120 240 PHASE 1 WIRE 3 CAT. Q0130S150L AMPS. 150 SYM, A.I.C. (I.E.R.) 10,000 MOUNT SURFACE MAIN M.L.O. GRID. BUS x CT DESCRIPTION POLE AMPS WIRE COND OA A 1-15 OUTLETS 1 20 #12 1 2" PANEL: SR MFG. SQ. D VOLTAGE 120 240 PHASE 1 WIRE 3 CAT. Q0130S150L AMPS. 150 SYM. A.I.C. (I.E.R.) 22,000 MOUNT SURFACE MAIN M.L.O. GRID. BUS X CT DESCRIPTION POLE AMPS WIRE COND OA OC 1,3,5 STAGE TRK. LTS. 1 20 #12 1 2" 7,9,11 STAGE TRK. LTS. 1 20 #12 1 2" 13,15 STAGE LTS. 1 20 #12 1 2" 2,4,6 SANCT. LTS. 1 20 #12 1 2" 8,10,12 SANCT. LTS. 1 20 #12 1 2 14,16,18 SANCT. LTS. 1 20 #12 1 2" 17s19-22 SOUND RM 1 20 #12 1 2" 23-30 SPARES 1 20 FINAL DESIGN 12/1/10 0 'C UPGRADES 12/8/09 REVISIONS StEWARDSHIP SERVICES P.O. BOX 238662 ALLENDALE. FL 32123 FL. LIC. # CB—0059189 Ministry in Church Facility Stewc Z U O o U Z o � Lj m D LLJ z Q 0 LLJ °- LLJ LJJ U (Q LL_ a 0 0 0 J Z LLI Q U � J � ~ �F__ Of 0 IZ 1�pNESsM1'p4o,Ozsui* A,NDAy44!li nUNAUTHORIZED ALTERATION OR ADDITION_TO_ THIS N� p�q0 �9NFROM THE ORIGINAL OF DRAWING IS A MOLAITON OF FLORIDA STATUTES. O p3fANft4NSBEARING AN SEAL, ECONSIDEREDRE 'QDSAT DATE 3/11 /03 COMM. NO. DRAWN BY JMP/PME * CIRCUITS 1 THROUGH 16 AND 18 TO OPERATE THROUGH DIMMER SWITCHES SHEET TITLE ELECTRICAL POWER PLAN U ectrica Power P a n SCALE: 1 /8" = 1'-0" PAUL M. ESTES, P.E. ELECTRICAL CONSULTANT / 615 NORTH PENINSULA DRIVE ! DAYTONA BEACH, FL. 32118 (386)-252-6948 \ FL. REG. PE # 33651 , SHEET NOTES 1. FIRE ALARM REMOTE ANNUNCIATOR. FLUSH MOUNT IN WALL TO CLEAR PLUMBING PIPING. PROVIDE LOW VOLTAGE INTERFACE BETWEEN ANNUNCIATOR AND FIRE ALARM CONTROL PANEL IN SOUND ROOM. min\lm 138 PLATFORM 4, M BAPTISTRY ACCORDIAN DOOR A ,9 /WA 2c#14 FPL T UP BOUND ROOM II OFFICE 2c#15 Sh FP 2c#14 FPL ® Wife IM—lb fA YSECRETARY ':., 1 137 MUSIC ROOM 151 ACCORDIAN DOOR 118 OFFICE `2c#14 FPL 2c#18 Sh FPL t20 D07 04 gg77 POMOR 2t 17 CONFERENCE t2 CE'S 12 D03 ME O ' z� RESTROOM RECEPTION 121 O O 128 C� 12 177 ( 12 2c#18 Sh FPL DOS D02 102 2c#14 FPL 52-9 D06 2c#18 Sh FPL NURSERY 12 3a cil FOYER ` STORAGE 135 101 C� 13 133 135 129 OFFICE HS #2 1os CLASSROOM 28 105 BATH 129 CLOSET HS2-11 HS1-10 H51-9 128 CLOSET 13D —BPARTITION LE D04 , ® 131 O RE /MU%UTao M S2-10 YOUTH os YOUTH eol TOD31ER 132 133 HS#1 CLASSROOM B HS1-1 OE) Dt S1-8 al [3FIo° r011 TECHNICAD 00 °oo 0 o ENGINEERING 0 0 0 ET ET 0 El SERVICES 943 South Ridgewood Ave. Fire /� a r m �"Awl P I a n Daytona Beach, FL 32114 (386) 246-1700 SCALE: N.T.S. HS1-3 16 WOMEN'S RESTROOM O Nl M08 FPL i vn, /" rc/c 4 FPL PP1-22 113 I I rM ELECTRICALM02 KITCHEN TEN 15 M �I / \El �� FUTURE HS1 HS1 8 sh FPL 109 IP, CLASSROOMS, i CHURCH, ETC. CLASSROOM LASSROI 107 toe \St-7 HS1-6 M05 FPL XFMRS 120/240 30-4W OPEN DELTA NOTE 2 NOTE 1 FIRE ALARM LEGEND —N.T.S FACP — FIRE ALARM CONTROL PANEL PER SPECIFCATIONS AND PANEL RISER DIAGRAM. RAA — REMOTE ALARM ANNUNCIATOR 1❑ — MANUAL PULL STATION 48" AFF TO TOP 7 — HORN/STROBE ANNUNCIATOR 84" AFF TO TOP D1 — SMOKE DETECTOR ® — HEAT DETECTOR ❑5 — STROBE ONLY ANNUNCIATOR 84" AFF TO TOP © — SPEAKER/STROBE VOICE ANNUNCIATOR 84" AFF TO TOP �7 — DUCT MOUNTED SMOKE DETECTOR W/AHU SHUTDOWN RELAY 2—#1 /0; 2—#4/0; IN11&1/2" C #1/0 N; #4 G; NOTE 5 gR IN 2" C 3—#4/0; \ #1/0 N; #4 G; NOTE 4 \\\ IN 2" C 2—#1/0: #1 N; #6 G; NOTE 3 Q IN 1&1/2" C FINAL DESIGN 12/6/10 0 A/C UPGRADE 12/8/09 REVISIONS 0 M N O 0 LL W W LU , UD w U C� J J L LL 0 _ o 0 N 0 co v N Q a�0 W F— nW - U /I \ W N C:> -1 C? LL T CO vI � _1 N W J co W J O J J O F O MDP LP PP1 PP2 PP2A JI I u /J NOTE 6 NOTE 8 NOTE 7 1-3"C. 3-500 KCM; U 1-250 KCM N; IN EA. OF 2-3"C. D SERVICE RISER DIAGRAM SCALE: NTS O T IL —L U D NOTES TO RISER: - Z 1. PROVIDE 2-2" C FROM NEW POLE TO NEW FPL TRANSFORMERS. PROVIDE PULL STRINGS AND COORDIATE REQUIREMENTS, SCHEDULE, ETC. WITH THAT UTILITY. W 2. OPEN DELTA TRANSFORMER CONFIGURATION — SET 2 PADS FURNISHED BY FPL AND PROVIDE m 1-3" CONDUIT BETWEEN TRANSFORMERS AS SHOWN. 3. PROVIDE FPL—APPROVED METER CAN AND SEAL RING IN LOCATION INDICATED ON DRAWING E-3. 4. SHUNT TRIP OPERATOR — MOUNT IN LOCATION INDICATED ON SHEET E-3, OR AS DIRECTED Li BY AUTHORITY HAVING JURISDICTION, AND WIRE TO OPEN MAIN BREAKER OF MDP. Z Q 5. LIGHTNING ARRESTOR TO BE SQUARE D MODEL SDSA3650 SURGE ARRESTOR, OR APPROVED EQUAL. 6, PANEL MDP TO BE 120/24OV, 3 PH 4 WIRE TYPE HCM SQUARE D PANEL WITH 120V SHUNT TRIP C)W ON MAIN BREAKER. LABEL MAIN BREAKER AS "SERVICE MAIN DISCONNECT #1 OF 1". SEE PANEL SCHEDULE THIS SHEET FOR ADDITIONAL REQUIREMENTS. O 7. SERVICE GROUND TO BE #2/0 AWG; CONNECT TO GROUND BUS OF PANEL MDP, BUILDING STEEL, 2-20 FT DRIVEN ELECTRODES 20 FEET ON CENTER AND TO COPPER WATER PIPES IF AVAILABLE. 0 LJJ 8. PANELS PP1, PP2, PP2A, LP AND SR TO BE AS INDICATED ON PANEL SCHEDULES INCLUDED WITH a- THESE DRAWINGS. NOTE THAT B PHASE MAY NOT BE USED FOR ONE OR TWO POLE CIRCUITS m m THROUGHOUT ELECTRICAL SYSTEM. I PANEL: MDP OPEN —DELTA BO HIGH MFG. SO. D VOLTAGE 120 240 PHASE 3 WIRE 4 CAT. HCM AMPS. 800 SYM. A.I.C. (I.E.R.) 22,000 MOUNT SURFACE MAIN 800/3 C/B* GRID. BUS X * WITH 120V SHUNT TRIP CT DESCRIPTION POLE AMPS WIRE COND OA OB Ot 1,3,5 AHU-1 3 60 #6 3 4" 7 9 11 AHU— 3 40 #8 3 4" 2 4 6 ACU-1 3 70 #4 3 4" 81012 ACU— 3 60 6 3 4" 18.20 PANEL LP 2 150 #1 0 1&1 2" 131517 PANEL PP2 3 225 4 0 2" 24.26 1 PANEL SR 2 1 150 X 0 11&1 2" 14 16 2 BLANK 30.32 1 PANEL PP1 2 225 4 O 2" 28 34 36 BLANK 19 21 23 SPARE 3 60 38 40 42 SPARE 3 40 25,27,29 LIFT STATION 3 30 #8 3 4" 31,33,35 PREPARED SPACE 37,39,41 PREPARED SPA E THESEPL M8 AX RE AECrTOPROPOSED POSEDWQUDF�CORp80N O;R,eK MAYgENE0jg4DlNSPECS RA ra NTHAT W11W ORDERto Q O p J Z W Q U Of J pi ~ Y I— O 0_ UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A MOLARON OF FLORIDA STATUTES ONLY COPIES MADE FROM THE ORIGINAL OF THIS DRAWING, BEARING AN ORIGINAL EMBOSSED SEAL, SIGNATURE AND DATE SHALL BE CONSIDERED TO BE VAUD COPIE DATE 12/08/10 COMM. NO. DRAWN BY JMP/PME i SHEET TITLE FIRE ('I ALARM PLAN SHEET PAUL M. ESTES, P.E. ELECTRICAL CONSULTANT 615 NORTH PENINSULA DRIV DAYTONA BEACH, FL. 32118 (386)-252-6948 - FL. REG. PE # 3 651 i��