St. Lucie County
EVALUATION REPORT Evaluation Report E10240.OS.OS-R4
East Coast Metals, Inc. FL5374-R4
2301 West 8 Lane Date of Issuance: (19103/2008
Hialeah, FL 33010 Revision 4: 03117/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use If
mentation submitted min
d has been reviewed by Robert Nieen, P.E. for
construction materials in the State of Florida. The docu
use of the product under the Florida Building Code and Florida Building Code, Residential Volume- The products described
herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED CoMPLIANcE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the produce changes or the
referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle. be displayed in
ADVERTISEMENT: The Evaluation Report number preceded by the words 'TrinitylERO Evaluated" may
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INsPEclota: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Segmrotion N, 597-66. Florida OCAANE1983
The fa¢muteseal appeari:fgs2sauthvrhzE by Rebm Ulminen,
Pion®/ir/]A1`+. Thudcesnotseree as a'dl .m uvsianed
daamen� 5''g w'.Wdhardwpil have been[masmiaetl to the
Pwdud APPmValAdnvai9[amrdndtn [he wmed client
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, or does it intend to acquire or will it acquire, a financial interest in any
company manufacturing or
distributing products it evaluates.
2. Trinity ERD is not owned, operated or controlled by any company manufacturing or products it evaluates.
distributing
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued. royal rocess of the
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the app P
Product. ERD nor Robert Nieminen, P-I_ are,. in any way, the Designer of Record for any
S. This is a building code evaluation. Neither Trinity)
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
s N Y t-11
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Prp a
Standard
Year
1507.3.7
Installation, non-HVHZ
FRSA/TRI April 2012[04-12)
2022
1518.8.1
Installation, HVHZ
RAS 218, 119 & 120
1995
1523.6.5.2.2
Static Uplift Resistance
TA5101
3.995
1711.2.1
Static Uplift Resistance
SBCCI SSTD 71
1997
3. REFERENCES:
Entity
Examination
Reference
Date
ERD(TST6049)
Static Uplift Resistance
E42730.08.13
08/23h-013
ERO (TST6049)
Static Uplift Resistance
ECIv1-SC6795.12.14-1
02/27/1015
ERO(TST6049)
Static Uplift Resistance
ECNI-SC679532.14-2
02/27/2015
Florida TEC(iST7393)
TAS101
510-628R
10/27/2010
PRI (TST5878)
TAS 101
ECM-002-02-01
09/21/2001
PRI (TST5878)
TAS 101
EC1.1-003-02-01
06/13/2008
PRI (TST5878)
TAS 101
ECr,4-004-02-01
06/13/2008
PRI(TST5878)
TAS 301
ECM-005-02-01
06/13/2008
PRI (TST5878)
TA5101
ECNi-006-02-01
06/13/2003
PRI (TST5878)
TA5101
ECM-007-02-01
06/13/2008
PRI (TST5878)
TA5101
E00-008-02-01
06/13/2008
Florida Building Cade
Attachment Requirements
FRSA/TRI April 2012(04-12)
04/2012
Florida Building Code -HVHZ
Attachment Requirements
RAS 128, 119 and 120
1995
East Coast Metals
Metal Quality
NIRI Certifications
Various
Architecture] Testing (QUA1844)
Quality Control
Participation Letter
E%P.12/31/2018
4. PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof -rile adhesive -
Hip & Ridge Channel Metal is available in 119-3/8-inch (±
3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch L3/8-inch)
heights with 1.5-inch (±1/16-inch) deck -flanges.
xterior Research and Design, LLG Evaluation Report F10240.08.08-R4
Cenljrute nfAuthotirotion Y95a3
FL53J4-R4
aevision 4: 03/17/2015
Page 2 of 7
TRINITY ERD
4.2 Trim Lock Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal Flange designed to receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch (±
3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights
with 1.5-inch (±1/16-inch) deck -flanges.
4.2 Trim Lack Plus Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC
Approved roof tile adhesive, which flows -through and
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/84nch
(±3/8") length by 3, 3.5, 4, 5 or 64nch (±3/8-inch) heights
with 1.5-inch (±1/16-inch) deck -flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
> Galvanized Steel: Min. 0.019±0.002-inch, ASTM A653 (G-90), min. 33 KSI.
> Galvalume Steel: Min. 0.019 ± 0.002-inch, ASTM A792, At55, min. 35 K51.
> Aluminum: Min. 0.032±0.002-inch, ASTM 8209, 3003-H14, min. 21 K51.
> Stainless Steel: Min. 0.019±0.002-inch, ASTM A240/A480, T304, min. 35 KSI.
5. LIMITATIONS: the Designer of
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert MerrimanP.E. are, in any way,
Record for any project on which this Evaluation Report, or previous versions
thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Evaluation Report E1o240.08.08-R4
Exterior Research and Design, LLG FL5374-R4
Certrj,-a afAuthurrrndcn 99503 Revision 4-.03/17/2015
Page 3 of 7
TRINITY [RD
5.2 FOR HVHZ JURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lack Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
_120,.and the _data .in Tables 3A and.1B is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,J or uplift resistance (F,),
as determined in accordance with RAS 127, not greater than the followin&values.
Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details.
Y "INDEPENDENr paddy placement means each individual tile is bohded to the Channel Metal in its own, single
foam paddy; file head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable
performance data below for "INDEPENDENT' paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
t "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bands the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT' paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLEIA: PERFORMANCE UMrrATIONS-.HVHZ, INDEPENDENT PADDY PLACEMENT
(21U1MARGWOFSAFkTYAOIF DYAPPOED)
Hip/Ridge
Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
type
Placement
Moment Based
Uplift Based
Mr(ft-Ihf)
F'(Ibf)
galvanizedHip&Ridge
day or
310-2-Component Foam
independent
127
Channel Metal
concrete
Roof Tile Adhesive AH-160
169
Trim Lock
galvanized, Galvalume,
day or
3M"'2-Component Foam
Independent
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
171
159
Trim Lock Plus
galvanized, Galwlume°,
day or
3M-2-Component Foam
Independent
177
aluminum orstainless steel
Concrete
Roof Tile Adhesive AH-160
165
_ TABLE 18: PERFORMANCE LLMrrATIONs- HVHZ, INTERDEPENDENT PADDY PLACEMENT
(4 To MARGIN OFSAFMY"EADYAPPDED)
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
Type
Placement
Moment Based
Uplift Based
Mr(ft-lbf)
F'(Ibf)
Trim Lock or Tdm
galvanized, Galvalumee,
day or
3M'"2-Component Foam
Lock Plus
aluminum or stainless steel
Concrete
Roof Tile Adhesive AH-160
Interdependent
95
88
Trim Lode
galvanized, Galvaiumea,
day or
3M'" Roof Tile Adhesive
stainless steel
Concrete
RTA-1
Interdependent
99
9q
Trim Lock
i aluminum
day or
3M"' Foam Roof Tile
Interdependent
90
gq
concrete
Adhesive RTA-1
Trim Lock Plus
galvanized, Galvalume°,
day or
3M'" Foam Roof Tile
Interdependent
90
aluminum or stainless steel
concrete
Adhesive RTA-1
gq
Trim Lock
galvanized, Gahralumee or
day or
TILE BOND- Roof-nle
I
stainless steel
concrete
Adhesive
Interdependent
123
117
Trim Lock
aluminum
day or
TILE BOND"' Roof Tile
Interdependent
79
73
concrete
Adhesive
Trim Lock Plus
galvanized, Galvalumes,
day or
TILE BOND"' Roof Tile
Interdependent
79
aluminum or stainless steel
concrete
Adhesive
73
Trim Lock-
galvanized, Galvalume°or
day or
Touch'n Seal StormBond
stainlesssteel
concrete
Roof Tile Adhesive
Interdependent
146
139
him Lock
Aluminum
clay or
Touch'n Seal StcrmBond
Interdependent
58
54
concrete
RoofTlle Adhesive
Trim Lock Plus
galvanized, Galvalume°,
day or
Touch'n Seal StarmBand
Interdependent
58
54
aluminum orstainlesssteei
concrete
Roof Tile Adhesive
Exterior Research and Design, I.I.C. Evaluation Report E10240.08.08-R4
Cedipeate of Authorization 99503 . FI5374-R4
Revision 4: 03/17/2015
Page 4 of 7
5.3 FOR NON-HVHZ JURISDICTIONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal, refer to th6installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturer's published installation instructions for adhesive paddy placement details.
> "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy, tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited
to 2-part file adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual file is bonded to the Channel Metal in a foam paddy,
and a second foampaddy bonds the file head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of cafpiv annlied to ultimate performance.
V TABLE2A: PERFORMANCE LIMITATIONS—NON-HVHZ, INDEPENDENT PADDYPIArFMENT
f2TO1 MARGIN OFMFETYALREAOYAPPOEOJ
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
IPsfj
Design
Metal Type
T e
YP
Placement
Hip &Ridge
Jay or
3M-2-Component Foam Roof
independent
169
Channel Metal
galvanized
concrete
Tile Adhesive AH-160
galvanized, Galvalumes, aluminum or
clay or
3M'"2-Component Foam Roof
Independent
173
Trim Lock
stainless steel
concrete
Tile Adhesive AH-160
galvanized, GalvalumeO. aluminum or
—jay or
3M-- 2-Component Foam Roof
Independent
178
Trim Lock Plus
stainlesssteel
concrete
Tile Adhesive AH-160
= TABLEZB:- PERFORMANCELIMITAnoNs—NON-HVHZ,INTMDEPENDEM PAOUYPLACEMENT -- -
(4 T01 MARGIN OFSAF£n'AIRFADYAPPIIEDJ
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(Psfl
Design
Metaliype
Type
Placement
Trim Lock or Trim
galvanized, Galvalume°, aluminum or
day or
31A- 2-Component Foam Roof
interdependent
98
Lock Plus
stainless steel
concrete
Tile Adhesive AH-160
galvanized, Galvalume' orstainless
clay or
3M— Foam Roof Tile Adhesive
Interdependent
110
Trim Lock
steel
concrete
RTA-1
day or
3M'" Foam Roof Tile Adhesive
interdependent
93
Trim Lock
aluminum
concrete
RTA-1
galvanized, Galvalumes, aluminum or
day or
3M— Foam Roof Tile Adhesive
Interdependent
93
Trim Lock Plus
stainless steel
Concrete
RFA-1
galvanized, Galvalume-or stainless
dayor
TILE BOND— Rooffile Adhesive
Interdependent
152
Trim Lock
steel
concrete
Trim Lock
aluminum
day or
TILE BOND- Roof-Ble Adhesive
Interdependent
82
concrete
galvanized, Galvalumeo, aluminum or
clay or
TILE BOND" Roof Tile Adhesive
Interdependent
82
Trim Lock Plus
stainless steel
concrete
galvanized, Galvalumes or stainless
clay or
Touch'n Seal Stormeond Roof
Interdependent
148
Trim Lock
steel
concrete
Tile Adhesive
--
joy or—
Touch'n Seal StomiBond Roof
Interdependent
61
Trim Lock
Aluminum
concrete
Tile Adhesive
galvanized, Galvalume°, aluminum or
—or
Touch'n Seal StonnBond Roof
interdependent 61
Trim Lock Plus
stainlesssteel
concrete
Tile Adhesive
Exterior Research and Design, U.C.Evaluation Report E10240.08.08-R4
FL5374R4
Certificate ofAuthorizadon 995113
Revision 4: 03/17/2015
Page of
ERD
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1Y4nch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 64nch o.c along both deck -flanges. Fasteners shall be
positioned Y-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to
FBC RA5118, Drawing 13, Detail 3; RA5119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.54nch wide deckflange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up priorto installation of roof tiles.
View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation
63.1 it is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
6.3.2 Approved underlayments are the codified '30190' system or other FBC Approved roof underlayments listing approved
use of the subject tile adhesive.
uterlor Research and Design, LLC. Evaluation Report E10240.08.08-R4
CertitTMW afAatharrsagaa MJ503 FLS374'114
Revision 4: 03/17/2015
Page 6 of 7
d RUTY ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved, published
installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118, RAS 119, RAS 120 requirements.
Hip / Ridge Tile
Tile Adhesive
Trim Lock Plus
Mortar or Weather Block
Adhesive
Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance priorto placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
B. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc.—QUA1844; (717) 764-7700
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC
rsrtl/fmte ofAurhodmdon N9503
Evaluation Report E10240.08.08-114
FL5374-R4
Revision 4:03/171201S
Page 7 of 7
r
TRINITY ERD
EVALUATION REPORT
T,��g-T-�^ ^^ Entegra Roof Tile, LLC
E V I `G1'C/'�'� - 1289 NE a Avenue
R o o F T I L E Okeechobee,FL34972
(602)515-6933
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
SCANNEa 353 CHRISTIAN STREET, UNIT#13
�� OXFORD, CT 06478
(203)262-9245
St. Lude COL)"tY
Evaluation.Report E39310.11.11-1-R4
FL7804-R10
Date of issuance:11/02/2011
Revision 4: 10/17/2017
SCOPE: applicable rules and regulations governing the use of
This Evaluation Report is issued under Rule 61G20-3 and the
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6' Edition (2017) Florida Building Code
(HVHZ) sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
nen
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert ie ties a complete
if the
product changes or the referenced Quality Assurance documentation changes. Trinity ERD re
quireview of this Evaluation Report relative to updated Code requirements with each
Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through B.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The IaaimOeseal appearingv+asauNarized hY Robert Nieminen,
P.Ean1011712o17. Thisdoes notcarveas an electmnlrally signed
document 51gned. sealed haNcopies have been lmnsmitted to the
Product Approval "ehinistrmer and m Me named (lent
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
s. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ERD
TRINITY'
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Tiles
Compliance Statement:—Entegra Concrete Roof Tiles, as produced UV—Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Cade through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Pro a
Standard
Year
1523.6.5.2
Physical Properties
TAS 112
1995
1523.6.5.2
Wind Driven Rain
TA5100
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102(A)
1995
3. REFERENCES:
Ent i
Examination
Reference
Date
ERD (TST6049)
TAS 101
P39740.02.12
02/21/2012
ATL(TST3782)
Physical Properties
RT0624.05-14
07/03/2014
ATL(TST3782)
Physical Properties
RT0624.04-14
07/07/2014
ATL(TST3782)
Physical Properties
RT1210.02-15
12/17/2015
ATL(TST3782)
Physical Properties
RT1210.03-15
12/17/2015
ATL (TST3782)
Physical Properties
RT1103.01-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.02-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.03-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.04-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.05-15
11/07/2015
Miami-Dade(CER1592)
HVHZCompliance
14-0416.12
11/27/2014
Miami-Dade(CER1592)
HVHZ Compliance
15-0721.04
11/05/2015
Miami-Dade(CER1592)
HVHZ Compliance
16-0112.06
02/25/2016
Miami-Dade(CER1592)
HVHZ Compliance
16-0112.07
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.08
02/25/2016
Tile Roof Institute
TAS 100, TAS 101, 102,102(A)
Membership Confirmation
Current
PRI (QUA9110)
Quality Assurance
Service Confirmation
Exp. 11/02/2018
Exterior Research and Design, U.C.
Evaluation Report E39310.11.11-1-R4
Certiflrote ofAuthanh tlon rf95M
6TM EDITION(2017) FeC HVHZ EVALUATION
FL7804-RIO
Entegm Roof Tiles
Revision 4:10117/2017
Page 2 of 8
a
4. PRODUCT DESCRIPTION:
4.1 TA5112Type 3a (flat -profile). -'
L r
1-1/r4'
I /
7
—r
2'
L_
y
Bermuda Flat
TRINIW ERD
+ BERMUDA FIAT, PLANTATION FLAT and HORIZON, FIAT-
FPlantailonFlat�
�4r171/4
13•
Horizon mat
Evaluation Report E39310.1L11-1-R4
Exterior Research and Design, LLC. FL7804-R30
certiifwte OfAutaoNzatlon a950 67 EDITION(2017) FBC HVHZ EVALUATION Revision 4: 10/17/2017
Entegra Roof Tiles Page 3 of 8
4.2 I TAS 112, Type 1a
4.3 TAS 112, T,
Holes ��
TRINITY. ERD
docking, high -profile) I BELLA HIGH "S
Bella High "S"
low -profile)
Estate "S"
4.3 1 TAS 112„Type'2a.(non-interlocking, high -profile)
17"
Galena Spanish "S"
10"
ESTATE "S" and HACIENDA
Hacienda
GALENA SPANISH "S" and REGAL
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4
Certnwte oJAuthoniation 99503 Gr"EDMON(2017) RIC HVHZ EVALDATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 4 of 8
TRINITY ERD
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting. FBC. HVHZ. requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112, Appendix W.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof
_ assemblies in FBC HVHZjurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in
accordance with Roofing Application Standard RAS 127-11 using the data outlined herein.
" TABLES: AERODYNAMIC MULTIPLIERS-)
-Tile
(FTa)3!r
Batten Application
ionBermuda
Flat
0.189
Plantation Flat
0.267
Horizon Flat
0.305
Bella High "S"
0.349
Estate "5"
0.267
Hacienda
0.267
Galena Spanish "S"
N/A
Regal
0.287
'' - • - TABLE2:]RESTORING MOMENT DUE TO:GRAVITY-M7(FT-LBF) -_-. --`
Roof Slope(0)
Tile
2:12<0<3:12
3:12<0<4:12
4:12<0<5:12
5:12<B<6:12
6:12<0<7:12
0>7:12
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Bermuda Flat
5.22
6.43
5.17
6.37
5.09
6.27
4.98
6,15
4.86
6.00
4.72
5.83
Plantation Flat
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Horizon
7.60
8.32
7.52
8.24
7.41 1
8.12
7.26
7.95
7.09
7.76
6.89
7.55
Bella High "S"
6.19
6.89
6.11
6.80
5.99
6.67
5.85
6.51
5.68
6.33
5.50
6.13
Estate V
6.14
6.84
5.91
6.74
5.82
6.64
5.70
6.50
5.56
6.33
5.40
6.14
Hacienda
5.92
6.80
5.92
6.80
5.82
6.69
5.70
6.55
5.56
6.39
5.41
6.22
Galena Spanish "S"
N/A
6.20
N/A
6.13
N/A
6.03
N/A
5.89
N/A
5.14
N/A
5.57
Regal
7.77
9.34
7.77
8.34
7.65
8.20
7.49
8.03
7.30
7.83
7.10
7.61
Erterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
cwiftr of Autharkodon #9503 bra EDITION(2017) FBC HVHZ EVALUATION FL7804-R30
Entegre Roof Tiles Revision 4:10/17/2017
Page 5 of 8
TRINITY ERD
TABLE 3A: ATTACHMENT RESISTANCE. EXPRESSED AS A MOMENT- MF(FT-LBF)
- - - :MECHANICALLY ATTACHED,SYSTEMS-
Tile
Fastener
Direct -Deck
(min. 15/32"
,plywood)
Direct -Deck
(min. 19132'
plywood)
Battens
Type
0
Size
Shank
Clip
Nail
One (1)
Sad
Smooth or Screw
N/A
7.3
9.8
4.9
Nail
Two (2)
lad
Smooth or Screw
N/A
14.0
18.8
7.4
Nail
One (1)
lad
Smooth or Screw
Eave
19.0
29.0
22.1
Nail
One (1)
lad
Smooth or5crew
Field
24.3
24.3
24.2
Bermuda Flat,
Nail
Two (2)
lad
Smooth or Screw
Eave
31.9
31.9
32.2
Plantation Flat or
Nail
Two (2)
lad
Smooth or Screw
Field
35.5
35.5
34.8
Horizon
Nail
Two (2)
lad
Ring
N/A
30.9
38.1
17.2
Nail'
Two (2)'
lad'
Ring'
N/A
50.3'
65.5,
48.3'
Screw
One (1)
N/A
N/A
_ 30.8
30.8
18.2
Sue
7wo-(2)
8
N/A
/AMM
Ms1.
'Installation with a 4-inch tile headlap and fasteners located min. 276-inch from head of tile.
Nail
One (1)'
lad
Smooth or Screw
N/A
8.8'
11.8'
4.1'
Nail
Two (2)
lad
Smooth or Screw
N/A
16.4
21.9
7.1
Nail
One (1)'
lad
Smooth or Screw
Eave
19.0'
19.0,
22.1'
Nail
One (1)'
lad
Smooth or Screw
Field
24.3'
24.3'
24.2'
Nail
Two (2)
lad
Smooth or Screw
Eave
31.9
31.9
32.2
"S"
Nail
Two (2)
lad
Smooth or Screw
Feld
35.5
35.5
34.8
Estate or Hacienda
Nail
Two (2)
lad
Ring
N/A
27.8
37.4
28.8
Nail'
Two (2)'
10d'
Ring'
N/A
43.0'
67.5'
50.9,
Screw
One (1)'
#8
N/A
N/A
25.8'
25.8'
22.9'
Screw
Two (2)
118
N/A
N/A
47.1
47.1
49.1
'Installation with a 4-inch file headlap and fasteners located min. 2X-inch from head of tile.
' For one (1) fastener installations, utilize hole that is approximately 4Y.-inch from the interlocking edge.
Nail
One (1)
lad
Smooth or Screw
N/A
5.1
6.8
2.8
Nail
Two (2)
lad
Smooth or5crew
N/A
6.9
9.2
7.3
Nail
one (1)
Sad
Smoothor5crew
Field
23.1
23.1
19.0
Nail
One (1)
lad
Smooth or Screw
Eave
29.3
29.3
24.0
Nail
Two (2)
lad
Smooth or Screw
Field
27.6
27.6
38.6
Bella High "5", Galena
Spanish "S" or Regal
Nail
Two (2)
lad
Smooth or Screw
Eave
38.1
38.1
41.8
Nail
Two (2)
lad
Ring
N/A
28.6
41.2
19.4
Nail'
Two (2)'
Sad'
Ring'
N/A
33.1'
48.1'
50.9,
Screw
One (1)
#8
N/A
N/A
20.7
20.7
18.2
Screw
Two (2)
#8
N/A
N/A
43.2
1 43.2
29.8
' Installation with a 4-inch tile headlap and fasteners located min. 2Y-inch from head of tile.
Exterior Research and Design, LLC Evaluation Report E39310.11.11-1-R4
Co"I Irmo ojAurhor1re#on MM 6'a EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10117/2017
Page 6 of 8
TRINITY! ERD
TABtE4: ATTACHMENT RESISTANCE- EXPRESSED ASA MOMENT-MF'(FT-LBF) - -
MORTAR AND ADHESIVE -SET SYSTEMS
Note from Entegra Roof Tile, LTC.: The performance data listed in Table 4 are based on the respectiveadhesive manufacturers, test
reports and Miami -Dade NOAs. Entegra Roof -rite, LLC relies upon the adhesive manufacturers to provide these values for our inclusion-.
in this FBC. HVHZ Evaluation Report. Please consult the individual adhesive. manufacturer for information on product approvals,-
limitations, revisions or other information for determining wind load and overturning moment. performance.
Tile Adhesive
Tile
Product
Product Approval
Placement
Mf(ft-lbf)
'TILE BOND'"" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
41
Bermuda
'Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
73
Flat,
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
52
Plantation
Flat or
Horizon
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent(2-paddy)
43
Independent (medium paddy, -30 g)
51
Independent (large paddy, -45 g)
92
'TILE BOND'"" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
44
'Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
42
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
44
Estate "S" or
Hacienda
"Polyset° AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent(2-paddy)
50
Independent (medium paddy, "30 g)
37
Independent (large paddy,-54 g)
61
Mortar
Various
Per RAS 120
21
"TILE BOND'"" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
48
'Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
52
Bella High
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
36
"S", Galena
Spanish "S"
or Regal
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent(2-paddy)
30
Independent (medium paddy, ^30 g)
49
Independent (large paddy, -63 g)
94
Mortar
Various
Per RAS 120
1 25
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
N T E G U \U\ U tn
U,
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
cerdflom ofAurhodrodon R9503 6EDITION(2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 7 of 8
I
-'TRINITY , ERD
�I' L
Hanson
Labeling: Horizon Flat, Hacienda, Regal
B. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant
Profiles "
Okeechobee, FL
Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUAUTy ASSURANCEENTITy:
PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
CertiJicote OfAuthodlad"n 49503 6" EDITION(2017) FBC HVHZ EVALUATION FL7804-R30
Entegm Roof Tiles Revision 4:10/1712017
Page 8 of 8
SCANNED
BY
St Lucie Coun
ENGINEER EVALUATE TEST
NEOREC$ae
Certificate of Authorization #32455
353 Christian Street, Unit #13
oxford, CT 06478
(203) 262-9245
CONSULT CERTIFY
EVALUATION REPORT
Boral Roofing Evaluation Report M35730.12.10-Rll
7575 Irvine Center Drive, Suite 100 FL14317-RID
Irvine, CA. 92618 Date of Issuance:12/21/2010
(602) 269-2288 Revision 11:10/12/2018
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the Win Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Boral Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8
Prepared by:
.1i=y"�-AF P
Robert l.M.Nieminen, P.E.
rT
The facsimile seal appearing was authorized by Robert
Florida Registration No. 59166, Florida DCA ANE1983
"v+•,:., ,;�;••"�
Mennen, This does not serve as an
electroniolly signed document
llyP.sin ddocumen
CEmRICAnON OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC Is not owned, operated orcontrolled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically forthat purpose.
i�enno etc.
ROOFING COMPONEuT EVALUATION:
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement:
Boral Roof Underlayments,
as marketed by Boral Roofing,
have demonstrated
compliance with the following sections of the 6`h Edition (2017) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/ Conditions of Use set forth herein.
STANDARDS:2.
Section
Pro a
Standard
Year
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, T1507-1.1,
Physical Properties
ASTM D1970
2015
1507.2.9.2
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
Enti -
Examination
Reference
--Date
ERD (TST 6049)
Physical Properties
M36790.07.11
09/30/2011
ERD (TST 6049)
Physical Properties
B40380.08.12
08/28/2012
ERD (TST 6049)
Tensile Adhesion/LTA
C41420.09.12-2
09/11/2012
ERD (TST 6049)
Adhesion
B41940.09.12
09/13/2012
ERD (TST 6049)
Tensile Adhesion / LTA
B47390.07.14-1
07/31/2014
ERD (TST 6049)
Tensile Adhesion / LTA
B47390.09.14
09/04/2014
OC(PDM1838)
Physical Properties
Equivalency statement
11/02/2017
PRI (TST 5878)
ASTM D1970
NEI-031-02-02:REV
10/27/2010
PRI (TST 5878)
ASTM D1970
NEI-029-02-01:REV
12/03/2010
PRI (TST 5878)
Tensile Adhesion / LTA
NEI-046-02-OSREV
12/17/2010
PRI (TST 5878)
FRSA/TRI April 2012
NEI-076-02-01
02/14/2011
PRI (TST 5878)
ASTM D1970
NEI-034-02-02
01/29/2013
PRI (TST5878)
Wind Uplift
BORR-001-02-01
03/17/2015
PRI (TST 5878)
Wind Uplift
BORR-005-02-01
06/24/2015
PRI (TST 5878)
Tensile Adhesion / LTA
DAPF-002-02-01
03/08/2018
PRI (TST 5878)
ASTM D1970 (adhesion)
OCF-443-02-01
10/11/2018
UL, L-C. (QUA 9625)
Quality Assurance
Service Confirmation
Exp. 08/21/2020
4.1 Boral® TileSeal SV is a nominal So -mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970.
4.2 BoralO TileSealm is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.3- Boralm MetalSeal" is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.4 GatorSealO is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.5 Citadel® Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roofing underlayment for use as a base -layer in multi -ply underlayment systems; meets ASTM D1970.
NEMO ETC, LLC Evaluation Report M35710.12.30-R11
Certijirate ClAuthonzolton A32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-RID
Boral Roof Underlayments; (602) 269-2298 Revision 11: 10/12/2011, Page 2 of 8
MEMO I etc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof
covers. Refer to the installation instructions for multi -ply underlayment options.
TABLE 1:
RooF COVER,OPTIONS
Underayment
Asphalt
Shingles
Nail-0n Tile
Adhesive -set
Tile
Metal
wood Shakes
&Shingles
Slate
Boral Tile5eal Sow
Yes
No
No
Yes
Yes
Yes
(RoTal-F1e5eal
Yes
Yes
Yes
(See 5.5.1)
Yes
Yes
Yes
Boml MetalSealw
Yes
Yes
Yes
(See 5.5.1)
Yes
Yes
Yes
GatorSeal
Yes
No
No
No
Yes
Yes
5.5.1 "Adhesive -set Tile" is limited to use of following Approved file adhesives / underlayment combinations.
Adhesive
Florida Product
Approval
Underlayments
DAP Foam Touch'n Seal StormBond Roof Tile Adhesive
FL14506
Boral Tileseal"r or Boral MetalSeal"
DAP Foam Touch'n Seal StormBond 2 Two -Component
Polyurethane Roof Tile Adhesive
FL21374
Boral TileSealw or Boral MetalSeal'
Dow TILE BONDTM Roof Tile Adhesive
FL22525
Boll TileSeal"r or Boral MetalSeal"r
ICP Adhesives Polyset®AH-160
FL6332
Boral TileSealw or Boml MetalSeal e
ICP Adhesives Polyset® RTA-1
FL6276
Boral TileSeal"T or Boral MetalSealw
' Refer to Tile Manufacturers orAdhesive Manufacturers Florida Product Approval for Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report M35710.1210-RSS
Certificate of4athorizodon#32455 6- EDITION (20171 FBC NON-HVHZ EVALUATION FL14317-RID
Boml Roof Underlayments; (602) 269-2289 Revision 11: 10/12/2018
Page 3 of 9
--- 6VEM0 I etc. ------
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Citadel Plus, Boral TileSeal 50"r, Boral TileSeal"r, Boral MetalSeal"T or GatorSeal:
➢ Plywood (unprimed or primed with ASTM D41 primer).
Boral TileSeaF or Boral Metal5eal':
➢ OSB (unprimed or primed with ASTM D41 primer).
Note: Refer to Section 5.6.4 far uplift limitations associated with direct -deck underlayment installations where the
overlying roof cover is adhesive -set tile roofing
5.6.2 Bond to Base Laver Underlayment:
Citadel Plus, Boral TileSeal 50", Boral TileSeal"T, Boral MetalSeal"T or GatorSeal:
➢ ASTM D226, Type II felt; Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under adhesive -set tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested
in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate Types:
Citadel Plus, Boral TileSeal 50'Ir, Boral TileSeal" ; Boral MetalSealw or GatorSeal:
➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.).
Boral TileSeal".
➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval.
5.6.4 Wind Resistance for Underlayment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does
not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the
underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer
to FRSA/TRI April 2012 (04-22), Appendix A, Table lA or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure=-120.0 post:
Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
Cap Sheet: Boral TileSeal"TorBoral MetalSeal"r,self-adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x lY" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
#2 Maximum Design Pressure=-142.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Sheet: Boral TileSeaF or Boral MetalSeal'n, self -adhered and back -nailed within the selvedge -edge side laps
using 12 ga. x 1%" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
NEMO ETC, LLC Evaluation Report M35710.12.10-R31
Cerolcate of AuthorzzaVon#32455 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R30
Borel Roof Underlayments; (602) 269-77M Revision 11: 10/12/2019
Page 4 of 8
RIEMO I et
#3 Maximum Design Pressure=-202.5 psf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSeal"r or Boral MetalSeal'r; self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1Y." ring shank nails through 32 ga, 1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-210.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: KARNAK #89 Sta-Tak Primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSealRTorBoral MetalSeal";self-adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1Y<" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-120.0 psf:
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional) Citadel Pius, self -adhered
Cap Sheet: Boral TileSeal'n or Boral MetalSeal"r, self -adhered
5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
5.7 Exposure Limitations:
GatorSeal shall not be left exposed for longer than 30-days after installation, priorto placement of final roof cover.
Boral TileSeal 50" , Boral TileSeal"T or Boral MetalSeal"r shall not be left exposed for longer than 180-days after
installation, prior to placement of final roof cover.
Citadel Plus, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than
180-days after installation, prior to placement of subsequent underlayment layer.
5.8 Tile Slippage Limitations [FRSA/TRI April 2012 (04-1211:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
FOR DIRECT -DECK
Underlayment
Tile Profile Staging Method Maximum Slope
Boral TileSeaPR or
eoralMetalSeaff
Flat Max. 10-tile stack 6:12
Lugged Max.10-tile stack 6:12
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40'F and rising.
NEMO ETC, LLC Evaluation Report M35710.12.30-R21
Cedifimte of Authodzodon#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R30
Boral Roof Underlayments, (602) 269-2288 Revision 11: 10/12/2019
Page 5 of 9
NEM I
6.4 Citadel Plus:
6.4.1 Citadel Plus is limited to use as a base or mid -layer in multi -ply underlayment systems beneath Boral TileSeal 50"r,
Boral TileSeal"T or GatorSeal.
6.4.2 Slope limitations are those associated with the top -layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by Y.-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch
diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the
black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6" end (vertical) laps.
Install final underlayment layer atop Citadel Plus per'direct-to-deck' instructions for Boral TileSeal 501r, Boral
TileSealn Boral MetalSeaF or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of Citadel
Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part
of a multi -ply system.
Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and
Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 501R, Boral
TileSeal"r or GatorSeal.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
6.5 Boral_TileSeal Se.-.
6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50"r on roof pitches less than 2:12.
6.5.3 Non -Tile Applications. Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by Y<-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge tothe deck with corrosion resistant roofing nails, nails &tin -tags or 1-inch diameter
plastic or steel cap nails spaced maximum 24-inch o.c. for slopes below 7:12 and maximum 12-inch o.c. for slopes
7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam
method detailed in Boral Roofing published installation instructions.
NEMO ETC, LLC Evaluaffon Report M35710.12.10-R31
Qefttnte of Authnmation#32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-RID
------ — — - -Boml Roof Underlayments; (602) 269-2288 _ __ _ - —.. . _ -_ .-. Revision 11: 10/12/2018
Page 6 of 8
----- - -- --- - -- --- -- --- MEMO I etc.
6.5.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal 50"T in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing published
installation instructions and Section 6.5.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.6 GatorSeal:
6.6.1 Shall be installed in compliance with the requirements for ASTMD1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non -Tile applications, Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by Y.-Inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roil into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails &tin -tags or 1-inch diameter
plastic or steel cap nails spaced 244nch o.c. for slopes below 7:12 and 124nch o.c. for slopes 7:12 and greater.
Overlap successive courses the entire width of the black -selvedge area, minimum 34nch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering
bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
6.6.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install GatorSeal overASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation
instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the granular top surface, rolling the interface into place with a weighted roller.
6.7 1,BoralTil6eal"Ioc.BoralMetalSealn': - -
6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.7.2 Do not use Boral TileSeal"T or Boral MetalSeal"T on roof pitches less than 2:12.
6.7.3 Non -Tile Applications, Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch.
Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the
exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller.
Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel
cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black -selvedge area,
minimum 3-inch.
Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
NEMO ETC, UZ Evaluation Report M35710.12.10-R71
Certificate of Authorirotion#32455 6'"EDITION (2017)FBC NON-HVH2 EVALUATION FL14317-R10
Banal Roof Undedayments; (602) 269-2288 Revision 11: 10/12/2018
Page 7 of 8
-------- - NEMo I etc.
6.7.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSealHT or Boral MetalSealw over ASTM D226, Type II felt or Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.7.5 rile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s),
Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, referto Section 5.6.4 herein.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeal"T
or Boral MetalSealHT with roof pitches of 231 to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
As required bythe Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Brentwood,
UL, LLC. — QUA9625; (631) 546-2458;
- END OF EVALUATION REPORT -