HomeMy WebLinkAboutSCREEN ROOM PLAN3" COMPOSITE "ELITE" ROOF PANELS (2LBEPSCOREXO.032"SKIN j THICKNESS). !}/' V O n 0 0 ° SEE ROOF FASTENING, DETAIL - ALUM. BEAM PER PLAN - (2" X 3" X 0.045" X 0.045"HOLLOW) . (1)-.3/8"THRU BOLTS THRU POST AND BEAM - 'ALUM. POST PER PLAN. ' (2" X 4- X 0,046" X. 0.100" SMB) 2" X.3" X 1/8" THK XZ"LONG ANGLE EACH SIDE W/ (3).-#14 SMS & (1) - W X. 2" EMBED CONC ANCHORS EACH. ANGLE 2" X 2" X 1/8-THK X 2" LONG ANGLE EACH SIDE W/ (3) #14 SIAS & (1)- 'X" X 2" EMBED CONC ANCHORS EACH ANGLE - 1" X 2" ALUM OPEN. BACK FASTEN PER - - - NOTE #1 G11 IIF- CONCRETE FOUNDATION PER PLAN rtanatrlH;,(II`s 'A TYPICAL POST SECTION (2 X 3 BEAM) nts... - 1/4" 0 THRU BOLT W/ 1¢/4" 0 WASHER Q loll O.C. (TYPICAL) - 3/8" 0 BOLTS REQ'D FOR 6" THICK ROOF PANELS O �0 n CT 0 O �\ O 0 ' -0 -.--- CONITNUGUSANGLE COMPOSITE ROOF PANEL 2" X 2" %1/8" FOR EDGE BEAMS FOR INTERMEDIATE BEAMS 2" X 2" X 3/16`THICK W/ x14 SMS @ 6" O.C. (TYPICAL) NOTE; THE Z'X21Xl/8" CONTINUOUS ANGLE MAY _ BEAM SELECTED FROM TA9LE BE ELIMINATED BY BOLTING TI IE COMW617 202 (MAY BE HOLLOW OR PArINELS THRU THE SUPPORTING BEAM SELF-MATING/LAP EXTRUSION ' SECTION ' ROOF PANEL FASTENING DETAIL (COMPOSITE PANELS) COMPOSITE ROOF PANEL RECEIVING CHANNEL WITH 014 XBOTTOM C 10" O.C. - TOP ANDND BOTTOM O O 00 4 CA O d O O EXISTING MASONRY FASTEN TO FASCIA WITH OR WOOD FRAMED 1/V0 X VAL" LAGS 12" ON CENTER HOST RUCTURE ETTEERR ALONG HEADER PERIMETER WALL NOTE; FASCIA MUST BE 2" NOMINAL 1" NOMI NAL FASCIA MAY BE AUGMENTED TO 2". �- COMPOSITE ROOF PANEL CONNECTION TO HOST FASUA I w, 3" COMPOSITE "ELITE".ROOF PANELS (2 LB EPS CORE X 0.03'2" SKIN THICKNESS) SEE ROOF FASTENING DETAIL ALUM. BEAM PER PLAN (20 X 4" X 0.046" X 0..1000 SMB) 1" X 2" ALUM. OPENBACK COST NOTCHED TO FIT BEAM (Q.)-3/8"THRU BOLTS THRU POST AND BEAM ALUM. POST PER PLAN (2" X 4" X 0.0460 X 0A00" SMB) OR (2" X 5" X 0.050" X 0.116" SMB). 2" X 3" X 1/8" THK X 2"LONG ANGLE EACH SIDE W/ (3) - #14 SIAS & (1) - Y..- X 2" EMBED CONIC ANCHORS EACH ANGLE 2" X 2" X 1/8"THK X 2" LONG ANGLE EACH SIDE W/ (3) #14 SMS & (1)- Y4" X 2" EMBED CONC ANCHORS EACH ANGLE " 1" X 2" ALUM OPEN. BACK FASTEN PER NOTE #1 CONCRETE FOUNDATION PER PLAN (4)410 X 1 %" SMS SCREWS ATTACHED THRU INSIDE OF IX2INTO SCREW SPLINES OF 3X2 BEAM - 3" X 2' X 0.090" X 0.090" ALUM --"- _ HOLLOW BEAM - - ROOF NOT SHOW .. - Planning & Development Services Department a Building & Code Regulations Division - - 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 412-1553 e+ or Certification EWSONiSC Load ENROOMCompliance Planning & Development Services Department Project Name: 6702 WOSCREENROOM Building &b Regulations Division ProJe<t Address: 6702 WOOOSMERE WAY FORT PIERCE, FL Product Review Affidavit Permit g: Occupanq Type: Construction Type: V INSTRUCTIONS FOR USE: ' •This certfflCation mug be completed, signed, and sealed by the design professional of reMr6 Building Pe17111t Owners Name 1�ZWd70w Applicant: • Submit (2) copies for residents], (3) copies for commercial with all permit applications lnvoMng the following: 0 New Residences (single or mufti -family) o Residential Addition o Any accessory structure requiring a building Permit o Any non-residential structure. ' Note: Form not required for interior renovations Provided that no esterior structural elemeRs are affected and certain minor building permits at the discretion of the local building official. Contact the x abore for questions. DESIGN LOADS IN ACCORDANCE WITH FBC 2017 TABLE 2002.4 DESIGN PARAMETERS AND ASSUMPTIONS USED. (complete II that apply) WITH REDUCTIONS PER TABLE 2002 4A Product Opening Design Product Rated Manufacturer Model Number Product Approval Glass Method of Attachment Pressures Desl n Pre5sure Number Type Roofing Material 41- `?AIrO "I'I- ^To - �(,1 r9C Is FL4 .75;0,1 NIA . ?c-lz' 1,7E'fAls.S Ohl .. PLG�:.h% 1. DESIGN CODE: Florida Building Code 2017 Edition with 20 _Supplements using AS:E 7-10 2. Structure Designed as (check one): _Enclosed X Partially Enclosed _Open 3. Risk Category: X I II_III_IV Exposure Category: _B X C D WINDSPEED Vult : 150 MPH r 4. Design Wind Velocity 150 mph 116 ASD N/A LRFD Enc1!one Width: 5 it _ S. Mean Roof Height: 8 h Roofs; M3 :12 Parapet. N/A If EXPOSURE; 6.Components&❑addiogDesignPressuresUsed:(VSF,basedan10SRfL@1s�MRH,dearlylabela„all plan openings): C I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the 31.0 31.0 31.0 29.3 29.3 N/A wind loads and forces specified by current code provisions. Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Goalie: -31.o a1.o -31.0 -z9a -29.3 N/A ON PLAN 7. Design Wads: Floor: 40 PSF Roof/Dead: 5 PSFRoof/ave: 20 Balcony:, N/A PSF Name: PAUL WELCH P.E. Signature: Dock: N/A PSF Deck:' N/A PSF Stairs: N/A PSFFence: N/A PSFRatlings: N/A PLF/CONCENTRATED HORIZONTAL PRESSURE ON WINDWARD SURFACE: 37 PSF 8. Were Shear Walls Considered For Structure? x ves_Notappll ble Fxplalnwhy Not: HORIZONTAL PRESSURE ON LEEWARD SURFACE: 29.3 PSF :PAUL WELCH P.E. Cert. No. 29945 Date: Design Prof: 9. ISA[ontinuous Load Path ProWded7 xvg:_Not APPhome Explain why Not: VERTICLE PRESSURE ON SCREEN SURFACE: 10.4 PSF VERTICLE PRESSURE ON SOLID SURFACE: 31 PSF - 30.Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes ' DESIGN PROFESSIONAL CERTIFICATION STATEMENT: - - ' 1 certifythat, to the best ofthe _.- ' ......�„,„,�„^...,„ ,_..,....... ..--•-----' .. - my knowledgeble structural of belief, theangcodescns&sy adopted davebeendesignedto ie- ComplyIalso with certify thatstruturaleements depicted on plartsurrovid adequatendenbrcet to Lucie County.l also certify that structural elements depicted on these plans provide adequate resisWce [„the design forces specified: f,..,. F.- �Y 1.-7 1• 19'�I.L:- G"..P N^• Q...Yr' IIG .. I`ri ' 6.J I'v Yii F')�� Paul Welch P.E. 29945 / 5115 I ✓ - Print Name Cent #&Co. Cart Auth. Paul Welch Inc.\\ L ON PLAN 12/27/2018 - \ Signature, Date, and Seal 19a4s-v Name Ad Tess I114 Port s2. Lode, FL IIp IIt ,� FOUNDATION SCHEDULE" _- ComPinY Name & Address _ I ,-... +..,. �e. .. �............... ... ` ... _._ 5LLtOV Form xUl„-]3 Reesee!/1S/11 p51 I / I I ' F-1 12' W X 8 (2500 PSI) CONCRETE MONOLITHIC FOOTING' \� 1^x:'an L'z3^De� t-T 11110 ORS. EWSROM PISESEFHOU-CACE OF - -. �I� F.n �I �tl �•Z W/(2)#S BARS CONTINUOUS y gFJr ETER FASTEN PER NOTE ,I l POST IIII O SINEW 51'IINES OF HOLLOW V. G '.1 r GIRT f lj2' ETIBEOMENT MINbIUM) i HOLLOW HOR120"TAL (GIRT) GIRT CHAIR OR ( 1 F-2 8" X S' (2500 PSI) CONCRETE MONOLITHIC FOOTING 1 � W/ (1) #5 BARS CONTINUOUS ;' 4" THK (2500 PSI) CONCRETE SLAB W/ FIBERMESH OR 6"/ 6" 10/10 WWM OVER VAPOR BARRIER ON L2, x 10 5.145. FP.OII INSIDE FACE DP I%2SElF F1ATING POST- ( - CLEAN COMPACTED CHEMICALLY TREATED FILL 13 t 00 HISEEFIENT 6PLIIIE6 OF HOLLOW GIRT. IuA' I - (i^a4eEa-IErDreNIMUMJ. �. 6-1.#5BARS XI2"LONG .DRILLED OUT AND EPDXIED WITH - CONNECROJI W/ CONCEALED FASTENERS' N 6., MIN. EMBEDMENT@ 4 O.C. ALL AREAS ADJACENT ONNECTION W/ CQNCEALED FASTENERS .'PARTIAL ELEVATIONS /GIRT TO POST CONNECTIONS ' `FOEXSTINGFOUNDATION PARTIAL ELEVATIONS / 2' X 2" GIRT TO 1" XZ" CONNECTIONS \�..:\ I ry x:" oe 0, FEwnETER ,.�„__•, .,.-- '.�; -- _- _ "` 2-4 10S.HS.FROMINSIDEFACEOF - �' � �\\\;�.- PEmIIETE0. E%1EIISIOIN IIO05CREW I - - - \\i� SLOTS OF PEPINEIF l -1/2" - _ \\'@.,_ EMBEDMEIIT I IIINIIiUFI) G2 \ 1. X\`�. I SHEET- � 1" X 20 ALUM OPEN BACK FASTEN PER 'I \ \ \ NOTE #1 REFER TO MOTE PI -THIS B I: L' ALUMINUM CORNER POST PER PLAN lids; WuK TIW 6ej, iNis II CORNER T HOST WAL ; 3X2 BEAM AT CORNIER AND HOST WALL DETAILS nts... CONNFCTION WITH N A! ED FASTENERq --- -- OARTIAL ELEVATIONS PERIMETER EXTENSION CONNECTIONS _ NOTES: ALUMINUM CORNER POST PER PL2" ALUM BACK FASTEN AlPER ` NOTE #1 9 (2"X2"X1/4"ANGLE W/(3)-#14XIYr"SMS .--� & (1)-3/8"X 2" EMBED CONC. ANCHOR (TYPICAL OF 2) I 0 r PLANVIEW CORNER POST TO FOUNDATION DETAIL nts_.. IZ ., •l 0.2°5 2 4/ I fro � ll�l.LI. p X Q CQ � 7� IKZ I<ZIIH 1) FOR ]x2 ATTACHMENT USE I/V 0 X 3^ LONG LAGS INTO WOOD HOST, Ke 0 X 2 W LONG CONCRETE SCREWS INTO CONCRETE OR MASONRY CONSMUCTIONAND N14 SMS X 2" LONG INTO ALUMINUM D- EMBEDMENT TYPICAL) / SPACING 24" O.C. AID WR 6" OF EACH PERPENDICULAR MEMBER It' 2) ALL PLANS IN ACCORDANCE WITH THE FBC 2014. 3) BOLTS AND OTHER FASTENERS SHALL BE ALUMINUM, STAINLESS STEEL, HOT -DIP OR ELECTROGALVANISED STEEL. DOUBLE CADMIUM PLATED STEELBOLTS MAY ALSO BE USED. 4) DURING ERECTION, STRUCTURAL ALUMINUM SHALL BE ADEQUATELY BRACED AND FASTENENED TO RESIST DEAD, WIND AND ERECnON LOADS. 5) ALL EXPANSION BOLTS SHALL NOT BE INSTALLED LESS TRAM r FROM THE EDGE OF CONCRETESLAB. 6) ALL FASTENERS SHALL HAVE HEAD, OR WASHERS NOT LESS THANA-IN DIAMETER. 7) NON STRUCTURAL. ALUMINUM SHEETS SHALL HAVE A MINIMUM TNCKNESS OF 0.032 INCHES (KICKPLATE, ETC...) 8) ALUMINUM IN CONTACT WITH CONCRETE, OR MASONRY MATERIALS SHALL BE PROTECTED _ WITHALKALI-RESISTANT COATINGS. 9) ALUMINUM IN CONTACT WTTH,WOOD TO BE PAINTED WITH TWO (RATS OF HEAVY -BODIED BITUOINOUSPAINT. 10) ALL SELF-MATING-WAMS (SMB) TO BE CONNECTED WITH BEAM STITCH SCREWS AT 24" O.0 BOTH SIDES (410 S.M.S. OR 012 SMS.) H VERIFY ALL DIMENSIONS 1D CTHEON CONTACT O B SUBCONTRACTOR. SUPPLIER CT. BALL , CONDITIONS A7 JOBSTEP,PLANS, ETAILEICATIO H ECT. 12) 3TRUCTURAI. FEATURES tt0T DETAILED ON 'THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AN CONSTRUCTION PROGRESSES. 13) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED , DIMENSIONS. 14) ATTACH KICK PLATE TO ALUMINUM FRAMING MEMBERS WITH 08 SMS AT 12" O.C. AND WITH INS"OFE ACH HERWISPERPENDI CULAR MEMBER MBe rvrz^ z••xz^Arm z^x3^ro IS BENTUNLUSNUMEM OTHERWISE NOTED ALUMINUM STRUCTURAL MERS , 1 BEMINIMUM DALUMINU ESS. _ 16) ALL EXTRUDED ALUMINUM TOT TS IA . LOR GREATER, LS._iLil�1LA C TENSILE STRENGTH OF (35 OF ,al) OR GREATER, YIELD STRENGTH OF (35kd) OR GREATER, AND COFtitPRESSiON STRENGTH OF - (10loQ OR GREATER 17) SCREEN DOORS MAY BE INSTALLED IN LOCATIONS OTHER THAN LOCATIONS AS SHOWN ON PLAN AS LONG AS NEW LOCATION DOES NOT INTERFERE WITH VIRTICLE POST LOCATIONS ORK-BRACINGI 18) SOIL BEARING CAPACITY: 2000 PSF(MIN.} - 19) SLAB I FOOTINGS TO BE CONCRETE WITH A MINM M 2500 PSI COAMESSIVE STRENGTH AT 26 DAYS. SEE PLAN FOR SIZES & STEEL REQUIREMENTS 20) MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTINGS: 3" 21) LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS EXCEPT AS NOTED GRADE 60 STEEL MINIMUM IN BEAMS AND COLUMNS. 22) SPLTUNG OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INHALATION OF HARDWARE IS NOT PERMITTED. ' 23) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRAC'IICUS. � �KZ ZAP; lx2 Ir2� Ix2: I s� \ T � x �jcC I? X `� r r ycle�tl.► �- 2>r2 (wo') 2x2 �%b�7 Ix2 7z", Ix2 Ix Ix2 ll .I r,J(y �51 P.IG►1: T . I A-t-(�t.l CbGFfn "^ 1p i I � �.t. .I I � ICI I 21t4 pox"!Irr'tvflple t� I- 'll II ST. LUCIE COUNTY BUILDING DIVISIO REVIEWED FOR COMPLI REVIEWE B TE PLA SAND PER IT \� MUST BE KEPT ON J B OR NO INSPECTION WILL BE MADE t n PJA THINE P1Af �a 'D ALL FRGROSFD Wv11l ARE SL%ECTTO,ANYCORRECTIONS +: RX1.11 ED RY FIELD INSPECTORS THAT S"i19Y lei NECESSARY IN ORDER TO COMPLY 1"1f FFI ALL APC•LIGW CODES. : CONCEALED FASTENERS ORATTAC ° HMENIS ARE THE RESPONSI81111YOF THE CONTRACTOR OFRECORO 90..COPY k' RECEIVED �•0 �a•� -� ---- 3f0 �IAOM -- DEC 2 8 2018 ST. Lucie Counr?,rI,'Permittli RECET`JED JAN10�i, ST PAUL WELCHINC. I MEChAN/CAL ELECTRICAL - CIVIL ENGINEERING f984S.W" B/LTMOREST SUITE# f 14 POR7-ST" LUCIE, FL 34984, HONE'I¢772)785.9888 E-MA/L PWELCIL•H/NCCSAOL.COM PAUL WELCH, P.E..FLA REG No. 29945 DEC 2' 7 2018 w U ^�^1� I on F- r O 0 SCANNED BY St: Lucia Count: SHEET NUMBER 74 0) F I I _ i