Manufacturer.
OWENS CORNING ROOFING AND ASPHALT LLC
1 Owens Coning Parkway
Toledo, OH 43657
(800)438-7465
www.owenswming.com
Manufacturing Location:
Brentwood, NH
.Houston, TX
Quality Assurance:
UL LLC (QUA9625)
SCOPE
Category.
Roofing
Subcategory.
Underlayments
Code Sections:.
1504.3.1,1507.1.1
Properties:
Physical properties
REFERENCES '
issued October 11. 2017
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (T5T5878)
NEt-039-02-M -
ASTM D 1970
21115
PRI Construction Materials Technologies (TSTS878)
NEI-042-02-01REV2
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
NO-045-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEHKS-02-01
ASTM G 15S
2005a
PRI Construction Materials Technologies (TST5876)
NE-053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
NEI-053.02-01
ASTM G 155
2905a
PRI Construction Matedals Technologies (TST5878)
NEI-093-02-02
ASTM D 1970
7A15
PRI ConstructionMaterials Technologies (TST5878)
OCF-213-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (TST5878)
OGF-237-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
2001
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 1970
2015
PRI Construction Materials Technologies (TSTS578)
OCF-25302-02
ASTM D 1970
2015
PRI Construction Materials Technologies (TST5878)
OCF-272,02-01
TAS 103
1995
PRI Construction Materials Technologies (TST5878)
OCF-296-02-02
[CC -ES AC 166'
2012
PRI Construction Materials Technologies (TST5878)
OCF-297-02-01.1
[CC -ES AC 48
ASTM D 1970
2012
2015
PRI Construction Materials Technologies (TST5878)
OCF318-02-01
ASTM D 1970
2D15
PRI Construction Materials Technologies UST5878)
OCF-32D-02-01
TAS 103
1995
PRI Construction Matedels Technologies (TST5878)
OCF-32D-02-01
ASTM G 155
2DDSa
PRI Construction Materials Technologies TST5878)
OCF-321-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies (rST5878)
OCF-322-02-01
UL 1897
2012
PRI Construction Materials Technologies (TST5878)
'Determined
OCF-35"2-01
UL 1897
2012
to be equivalent to ASTM D 226-09. Type I
and 11
SCANNED
BY
St. Lucie County
i ms evanuation report is provided for State of Florida product approval mdar Rule 61G2O3. The manufacturer shag n00y CREEK
Technncal Services, LLC of any product charges or quality assurance changes throughout the duration for which this repot is valid.
This evaluation report does not express nor empty warranty, installation, recommended use, or other product atidb ites ghat are not
specifically addressed herein
CREEK OWMISGUIQHN Krt ruv�wru.axnr�. LL-
Weathe'Lo W Self-sealing Ice a Wad Barriers
TECHNICAL SERVICES, LLC -
PRODUCT DESCRIPTIONANDLOUTS OF USE ,
Weather[A)CM G
WeathednclkO G is an ASTM D 1970 self-adhesive undedayment constructed from SSS
'
(Brentwood, IVH)
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product 1s supplied In 2-sq. rolls with nominal dimensions of 3-ft x 66.7-fl.
Weathert-odS G is pennilted to be used as prescribed in FBC Section 1507.1.1 for
mechanically attached roofing coverings_ Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLocW Mat
Weathed-odO Mat is an ASTM D 1970 self-adhesive undedayment constructed from
(Brentwood, NH or
SBS modified asphalkwith a fiberglass mat reinforcement The product is supplied in 1-
Houston, M.
- sq. rolls with -no anal dimensions of 3-ft x 33.3dt and 2 sot. rolls with nominal dimensions
of 3-ft x 66.7-ft
WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for
- mechanically, attached roof covedngs.. Exposure on the roof deck shall be limited to a
maximum 30 days.
WeatherLockO Metal
WeatherLock@ Metal is an ASTM D 1970 self-adhesive undedayment constructed from
(Brentwood, &"
SBS modified asphalt with fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq. roils W th_nominal dimensions of 3-ft,x 66T-4L
Weafherlack®Metal is permitted to be used as prescribed 'm FBC Section 1507.1.1 for
mechanically attached. roof coverings. Exposure on. the roof deck slug be limited to a
maximum 90 days.
WeatherLockO Wealhed-ock® Specialty Tie &Metal is an ASTM D 1970 self-adhesive undedayment
specialty Tale & Metal -constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH or The product is supplied In 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-R
Houston, TX)
WeatherLodk® Specialty Tile & Metal is permitted to be used as prescribed in FBC
Section. 1507.1.1- WeatherLoek® Specialty Tile & Metal is permitted to be used with
adhered clay or concrete the roofing using either ICP Adhesives Polyset AH-160 (ICP
Adhesives and Sealants, Inc.) or TILE BOND = Roof Tile Adhesive -(The Dow Chemical
Comparry). Exposure on the roof deck shag be limited to a maximum 90 days.
The maximum roof slope shag be 6:12 when used with day or concrete file installations
without battens_ Tile shall be stored on battens for roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 dies per stack.
- WeatherLock® G (High WeatherLock&1 G (High Tear) is a self -adhered, undedayment used as an alternative to
Tear) ASTM D 226, Type I or Type 11 roofing felt and ASTM D 1970 self -adhering polymer
(Houston, 7X) modified bitumen undedayment The undedayment is composed of SBS modified
asphalt with a fiberglass mat internal reinforcement and is surfaced with granites. The
product is supplied with a nominal thickness of 50 mils in 1.95-sq rafts with nominal
dimensions of 3-ft x 65-IL
WeatherLock® G (Ffigh Tear) is permitted to be used as prescrbed in FBC Section
1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be
limited to a maximum 30 days.
Technical Services, LLC of any product changes or quality assurance changes throughout. the duration for whidx this report is valid.
This evaluation report does not express nor imply warranty. Installation, re=rnemled use, a other product attributes that are not
specifically addressed herein
LLC
TECHNICAL;SERVICM, LLC
PRODUCT APPLICATON - -
Min. Roof Slope: 2:12 in accordance with the FBC
Application: All undedayments shall be installed in accordance with the FBC.
Dank substrates shalt be clean, dry, and free from any irregularities and debris. Ali
fasteners in the deck shall be checked forpretmsion and consoled prior to undedayment
applcation. Prior to beginning installation, tha .airdedayment shall be. taimfled and
showed to relax fora.mirtimum of 3-5 minutes
The undedayment,shall be installed with thi release backer removed and pressed firmly
Into place to ensure complete contact with the deck.'Tie undedayment shall be installed
with the roll length parallel to file eave,.starting-at. the save, and with minimum T side
laps and minimum.6' end taps staggered min. 6-Rfmm preceding course. Additionally, if
applying WeatherLock® Specially Tile & Metal, end laps shag be primed with ASTN D
41 primer or sealed with asphalt roof cement a minimum of 3.4 inches across the width
of the lap.
It is permissible to back nail the andertayment 12-inches on -center as needed (nails shall
be installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). Additionally, WeatherLock® Specialty Trio & Metal shall be back nailed
when installed on r ref slopes greater than 3:12.
Min. Appfcation 40'F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
WIND RESMANCE
The Maximum Design Ressures shown below were calculated using a 2:1 margin of safety per FBC Section 15".9
Undedavment System No.1— Weatheltock Specialty Tile & Metal Only
Roof Deck: Min.15132-inch CDX plywood attached to wood supports spaced a maximum 24' o.c. -
Underiayment Weatherl-oekill Specialty Tile & !Natal shall be applied in accordance with
manufacturer's installation instructions to the fastened deck and bacutailed along the
selvage with minimum 12ga., 1-114-inch galvanized ring shank mating nags through
optionally primed, 32ga. x 1-5/6-inch 0 tin caps spaced 12' o.a The applied
underlaymant shag be roiled with a .minimum 751b steel roller immediately following
applcation. -
Maxlmum Design -142-5 psf
Pressure:
3 or4
Technics Services, LLC or any Product changes or gpaiity esstirm oe Granges flwughotd the duration for which this report is valid.
This evaluation report does not a-Vress nor imply warranty. installation, recommended use, or other product attnoutes that am not
specifically addressed herein. .
OWENS CORNING ROOFING AND ASPHALT LLC
Weatherl-ockb SelfSeating lee & Water Barriers
TECHNICAL SERVICES, LLC
GENERAL
1) This evaluation report is not use in the HVHZ.
2) Fee Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturers published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed of closely fdted plywood sheathing for new or existing construction.
5) The space under the deck area stall be property ventilated in accordance with the FBC requirements.
6) All side lap seams shall be installed to shed water from the deck
7) The underpayment may used as described in other current FBC product approval documents.
8) Design "wind load pressures shag be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shag be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components anddadc ing-
10) Maximum Design Pressures for a given underlayment shall meet or exceed "the design wind loads
determined for the roof assembly. "
11) AD products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20.4. "
COMPUANCE STATEMENT
The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building
Code Ga' Edition (2017) as evidenced In the referenced documents submitted by the named manufacturer. ,
A.
2017.10.1
No 74021 =
_09:06:29
-04 00
9: STATE. OF .41
�Zachary
Ir ' :l O R 1 O �`
R. Priest P.E.
Fl ridaRegistration No. 74021
old &%- c�����.
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have,.nor will it acquire, a. financial interest in any company manufacturing or distributing
Products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any comparry manufacturing or distributing products under
this evaluation.
Zachary R. Priest, RE does not have, nor will acquire, a financial Interest in any compairy manufacturing or distributing products
under this evaluation.
Zachary R. Priest. P.E. does not Crave; nor will acquire a finandal interest in any other entity involved in the approval process of the
product
END OF REPORT
�nivuuLaa FL9777-R11 Page 4 of 4
This evaluation report is provided for State of Fluids product approval under Rule 61G203. The manufacturer shall nobYy CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, rec«nmended use, or other product attributes that are not
specifically addressed hereto -