BLOWER DOOR TEST FORM
Grouse infiltration Test Certification
Prescriptive and Perf®rmance Method
I C>
EEB 0 5 2020
ST. Luci.e County, Permitting
SCANNED
By
St, Luce County
Permit;: of — 0Z11
( cj New Construction — Cornplete
I-
( ) Existing —After Addition
House Infiltration Test Results SI.0 Climate Zone 2
Volume, _ 1 ) ? 3 o Test Date: ( i.1 -L.3 �( i
ACH (50) = CFM (SO) r[ Go / Volume = _ 3 " Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less
{Pass ( )Fail
F6C,Energy
T he building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an
approved third parry. A written report of the results of the test shall be signed by the parry conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
F8C. Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (5o Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name: Pro -Duct Services
Address: '1915 P,lo Vista Drive, Ft. Pierce, FL 34949
I hereby certily thatthe above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Martin Klein
License/Certification #: 5061633
BUILDING PERFORMANCE INSTITUTE, INC.
107 Hermes Road, Suite 210
Malta, NY 12020
(877) 274-1274
y
www.bpi.org '
Martin Mein
.. 6PiIDW:60fi1639
(SEE REVERSE SIDE FOR DESIGNATIONS AND EXPRA'RON OATES)
CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE
Infilk-tion&Duct Lc.bp(ML) 4r2512021
BUILDING PERFORMANCE INSTITUTE, INC.