HomeMy WebLinkAboutREVISION - MISC LETTERFl. Design Build Inspect Architecture + Construction + 12/4/19 r CRC1331263 I AA26003142 I H110776 To: St Lucie County Building Department 'SCANNED Sy Re: Carter Residence, permit # 1901-0212 St. Lucie County 1. Please allow contractor to install Hardie Plank horizontal lap siding on the front facade as per revised product approval affidavit dated 12/4/19. 2. The doors and roofing product approvals changed per revised product approval affidavit dated 12/4/19. Thank you, lS�Or F(Q� 4i O al�SIs a. y 1 4 P�: /� —a— A9)IO9 ^' C•., ............. �� Frank Liebler Owner / Architect / Contractor FL Design Build Inspect Construction + Architecture + Home Inspection CRC1331263 i AA26003142 1 H110776 frank.liebler@gmail.com c 772.321.4500 �� 19 RECE FOR COD LIANCE ST. LUCIE COUNTY BOCC 0 FIve Copt BLDG DEPT CORRESPONDENCE 11 of 1 PRODUCT APPROVAL AFFIDAVIT- Carter Residence-12/4/19 GLASS ITEM TYPE Mi BUILDING DP2 PRODUCT.• TYPE s MFIR MODEL FRENCH DOORS ALL So, -So IMPACT Therma-tru Smoothstar FL 20468.12 60U73'7 OVERHEAD ALL 36,-44 N/A DAB Hurricane Master NOA 17-1018.12 OOQjW D3 ALL 50,50 N/A Thermal-tru Smoothstar FL 20461.6 WINDOW S.HUNG ALL 50,-70 IMPACT PGT SH-5500 FL239.7 WINDOW PICTURE ALL 50,50 IMPACT PGT PW-5520 FL243.9 WINDOW MULLION ALL 79.6 N/A PGT 1.25"0.25"z.100" NOA 17-0630.01 IDIN ALL ALL lames Hardie HardiePlank FL 13192 direct to block w/ 1.25" block nail per approval @ 24" oc ROOFIN UNDERLAYMENT ALL N/A Owens Corning weatherlock FL9777.7 METAL ALL -25field, -65 edge -69.25 N/A JATaylor 5v crimp FL 17443.1 16"cc option 1.'ID'as per door&window schedule, or all meaning worst case of all similar items of that type. 2. If building p are left blank- see door & window schedule or design pressure chart. 3. This affida t is only to verify product's compliance with wind loads. 4. Unless pro�ucts are specifically submitted for verification by contractor, they are assumed. 5. If glass type is not specified more than 'impact', may use any of the impact glass type in the install instructions to achieve the stated building design pressures. 6. If fasteners s left blank, may use any of the specified attachment methods In the Install instruction matching structure provided to achieve the stated building design pressures. 7. I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. FRANK LIE ILER, ARCHITECT (AR97108) AR97108 DBL 2x 2x81x lx DBL 1x 2x 1. BUCK TO CMU W/ .25' x 1.25" EMBED TAPCON @ 17 OC STAG 2. BUCK TO CMU W/.25" x 1.25" EMBED TAPCON 6" FROM ENDS & MIDDLE 3. BUCK TO 2x BUCK W/ 1.5" EMBED SCREW @ 12" OC STAG 4. BUCK TO CMU W/ 6D CASE HARD NAIL @ 12" OC STAG 5. WIN OR DOOR TO 2x BUCK AS PER MFR 6. WIN OR DOOR THRU 1x BUCK INTO TO 2x AS PER MFR 7. WIN OR DOOR THRU 1x BUCK INTO CMU AS PER MFR - PLYWOOD 3/4" OR LESS CAN BE SUBSTITUTED FOR 1x BUCK - MINIMUM WIDTH FOR SINGLE 2x BUCK IS 3.5" - MINIMUM WIDTH FOR DBL 2x BUCK IS 5.5' ALTERN/ SCALE: 3"= 1'-0"