HomeMy WebLinkAboutEVALUATION REPORTRECEIVED — - - - - JAN 1 5 2019 SF. Lucie County, Permitting NEMO l etc. SCANNED Certificate of Authorization R32455 BY 353 Christian Street, Unit #13 Sir Lucie County Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY 7N RFPOR Polyglass USA, Inc. Evaluation Report P9290.02.08-R21 Fernley,Lyon Drive FILE COPY 02/11/2008 FerNV 89408 Date of Issuance: 02/11/2008 (954) 233-1330 �Revision 21:10/08/2018 SCOPE: �tpWfA.lt� l I C/1 —bZ6e'3 This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 60' Edition (2017) Florida Building Code sections noted herein CONCFALED FASTENERS OR ATTACHMENTS AR�ZifE OR EC OF D DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems CCtl�NfR OR RECORD LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 65-page Appendix -THESE PLANS AND ALL PROPOSED WORK Prepared b : ARE SUBJECT TO ANY CORRECTIONS P Y ,PS csa. i REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO UOMPUf b",r!TH ALL APPLICABLE CODES. �T�. FPd'E :OF:WF Robert J.M.Nieminen, P.E. '•.,`fFsA •;Fyi'' The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DC4 ANE1983 .".: ,w; �,�„````- Nieminen, P.E. on 10/08/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. �Ww- ,/-� n - . W , �-+ of -0�3 ST. LUCIE COOT REVIEWED FOR PLANS AND PERMIT MUST BE KE,PTJON Juts SITE OR NO INSPECTIONS) WWVSE MADE NEmo etc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6t6 Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.3.1 Wind UL 1897 2012 1504.7 Impact FM 4470 2012 1507.11.2 Physicals ASTM D6162 2008 1507.11.2 Physicals ASTM D6163 2008 1507.11.2 Physicals ASTM D6164 2011 1507.11.2 Physicals ASTM D6222 2011 1507.11.2 Physicals ASTM D6509 2009 Entity Exam Reference Date .Entity Exam Reference Date ERD (TST6049) Physicals P30490.30.08-2 30/30/2008 FM(TsrlB67) FM 4470 2DOAO.AM 12/23/1998 ERD (TSr6049) FM 4470/4474 P13760M-09 09/10/2009 FM (TST3867) FM 4470 2DSA9AM 06/22/1999 ERD (TST6049) FM 4470/4474 P33770.09.09 09/10/2009 FM(TST1867) FM 4470 3006646 Ol/04/2000 ERD(TST6049) FM 4470/4474 P30540.11.09-RS 11/30/2009 FM(TSr1867) FM 4470 3001334 01/25/2000 ERD ITS1­6049) FM 4470/4474 P30550.12.09 12/02/2009 FM (TST3867) FM 4470 3001334 02/15/2000 ERD (TST6049) Physicals P33960.12.10 12/30/2010 FM(TST1867) FM 4470 30DO857 01/12/2000 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 FM(TST1867) FM 4470 30=91 01/12/2000 ERD (TST6049) Physicals P37590.03.13-3A 03/06/2013 FM (TST3867) FM 4470 3006115 05/02/20DI ERD (TST6049) FM 4470/4474 P39680.03.13 03/04/2013 FM(TST3867) FM 4470 3012321 07/29/20D2 ERD M60491 Physicals P37590.03.13-1-R1 06/26/2013 FM UST1867) FM 4470 3014692 08/05/2003 ERD(rST6049) Physicals P37590.03.13-2-RS 07/01/2013 FM(TST3867) FM 4470 3014751 08/27/2003 ERD ITS1`6049) Physicals P37590.07.13-2 07/01/2013 Fly(TST1867) FM 4470 3007170 01/13/2004 ERD (TST6049) Physicals P37590.03.13-5-111 07/01/2013 FM(TST2867) FM 4470 3019317 06/30/2004 ERD (TST6049) Physicals P37590.07.13-1 07/02/2013 FM(TST3867) FM 4470 3020703 07/30/2004 ERD (TST6049) FM 4470/4474 P41630.08.13 08/06/2013 FM (TST3867) FM 4470/4474 3018332 01/31/2006 ERD (TST6049) Physicals P45940.09.13 09/04/2013 FM (TSr3867) FM 4470/4474 3023368 03/2D/2006 ERD (TST6049) Physicals P44370.10.13 10/04/2013 FM(TST1867) FM 4470/4474 3024594 05/23/2006 ERD CW6049) Physicals P39520.09.14-2 09/11/2014 FM (TSr1867) FM 4470/4474 3023458 07/18/2006 ERD (17ST6049) FM 4470/4474 SC6160.11.14 11/10/2014 FM (TST3867) FM 4470/4474 3030668 09/12/2007 ERD(TSI-6049) Physicals P45440SCO3.15-1 03/31/2015 FM tTST186]) FM 4470/4474 3032172 06/12/2009 ERD (TST6049) Physicals SC5170.05AS 05/08/2015 FM(TST1867) FM 4470/4474 3049631 04/21/2014 ERD (TST6049) FM 4474 SC8085.05.15 OS/19/2015 FM(TST1867) FM 4470/4474 3057029 02/02/2017 ERD (TST6049) Physicals SC5170.12.15 12/29/2015 NEMO (TST6049) Criticality 4S-PLY13-18-001.06.18 06/23/2018 ERD(T5T6049) FM 4470/4474 SC9455.15 04/01/2016 NEMO (TST6049) FM 4474 4L-PLYG-18-003.08.18 08/21/2018 ERD M6049) FM 4470/4474 PLYG-SC8905.05.16-1 05/17/2016 NEMO (TST6049) FM 4474 PLYG-Cl, 0, C4, C5,a 09/21/2018 ERD (TST6049) FM 4470/4474 PLYG-SC8905.05.16-2 05/17/2016 NEMO (T5T6049) Criticality 45-PLYG-18-001.10.19 10/03/2018 ERD (TST6049) FM 4470/4474 PLYG-SC198n.07.16A1 09/23/2016 PRI (TSr5878) Physicals PUSA-062-02-01 12/64/2DO7 ERD (TS1`6049) UL 1897 PLYG-SC32025.10.16 10/12/2016 PRI (TST5878) Physicals PUSA-061-02-02 01/28/2008 ERD (TST6049) FM 4470/4474 PLYG-SC11475.16 11/17/2016 PRI ITST5878) Physicals PUSA-064-02.02 OZ/27/2008 ERD (TST6049) FM 4470/4474 PLYG-SC13235.01.17 01/17/2017 PRI(TST5878) Physicals PUSA-062-02-02 12/04/2008 ERD(TST6049) FM 4470/4474 PLYG-SC13920.05.17 05/30/2017 PRI(TST5878) TAS 114 PUSA-188-02-01 02/09/2017 ERD (TST11294) FM 4470/4474 PLYG{ 113945.05.17-1 05/30/2017 PRI (TSTS878) TAS 114 PUSA-188-02-02 02/08/2017 ERD(TST11294) FM 4470/4474 PLYG{,i1.13945.05.17-3 05/30/2017 PRI(TSTS878) TAS 114 PUSA-188-02-03 02/08/2017 ERD (TST6049) FM 4470/4474 PLYG-SC33945.05.17 05/30/2017 PRI (TSr5B78) TAS 114 PUSA-202-02-01 05/17/2017 ERD (TST6049) FM 4470/4474 PLYG-SC15760.09.17 09/11/2017 PRI (TST5878) TAS 114 PUSA-202-02-02 05/17/2017 FM (T5T1867) FM 4470 2W7A7AM 08/04/1994 M-D (CER1592) HVHZ Various NOAs Various FM(TST1867) FM 4470 OWA3.AM 04/04/1997 M-D(CER3592) Prop. for Rev. 10-0823 10/12/2010 UL (QUA9625) QualityControl Service Confirm 09/13/2018 NEMO ETC, LLC Evaluation Report P9290.02.08-R21 Certificate ofAuthonc don N32455 lira EDITION (2017) FBC NON-HVHZ EVALUATION FLI654-RZ3 Polyglass Modified Bitumen Roof Systems; (954) 233.1330 Revision 21; 10/08/2018 Page 2 of 4 etc. This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subiect systems. TABLE Type 1: ROLL -GOODS FOR POLYGLASS MODIFIED BITUMEN Product ROOF SYSTEMS Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A II Polyflex SA Base ASTM D4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A SBs Membranes Polyglass HT Base 650 ASTM D6162 S III Elastobase ASTM D6163 5 1 Elastoflex V ASTM D6163 S I Elastoflex SA V Base ASTM D6163, Table 2 S I Elastoflex SA V FR Base ASTM D6163, Table 2 S I Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase Poly - ASTM D6164 5 I Elastoflex S6 ASTM D6164 5 1 Elastoflex S6 Type II ASTM D6164 S II Elastoflex VG ASTM D6163 G I Elastoflex VG FR ASTM 06163 G I SBS Membranes Elastoflex S6 G ASTM D6164 G I Elastoflex 56 G FR ASTM D6164 G I Polyfresko G 58S (sand or poly -film back) ASTM D6164 G I Polyfresko G 5BS FR (sand or poly -film back) ASTM D6164 G I Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyreflect ASTM D6164 5 1 APP Membranes Polyflex ASTM D6222 S I Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G I Polyfresko G ASTM D6222 G I Polyfresko G FR ASTM D6222 G I Polybond ASTM D6222 5 1 Polybond G ASTM D6222 G I PolVflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 G I Polyfresko G SA ASTM D6222 G I Polykool ASTM D6222 S I 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically forthat purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 26D3.6 apply. NEMO ETC, LLC Evaluation Report P9290.02.08-R21 certificate ofAuthorimtion N32455 6' EDITION (20171 FBC NON-HVHZ EVALUATION FL1654-R23 Polyglass Modified Bitumen Roof Systems; (954) 233-2330 Revision 21: 10/08/2018 Page 3 of 4 — - - - - - - - - - -- -- -- - *NEMO etc. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure forthe selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1),1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 614320-3. 6.1 Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements 9. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625; (314) 578-3406, k.chancellor@us.ul.com - THE 65-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO ETC, LLC Evaluation Report P9290.02.08-1121 Certifoate of Authorization#32455 6'"EDITION (2017)FBC NON-HVHZ EVALUATION F1.1654-1123 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Revision 21: 10/08/2018 Page 4 of 4 i NEMOI tC. APPENDIX I: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE I DECK - APPLICMRecover TYPF DESCRIPTION pAG 1A Wood New or Reroof (TearA-1 Bonded Insulation, Bonded Roof Cover 5 1B Wood New or Reroof (TearA-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 1C Wood New, Reroof (Tear-Oer A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof CoverSD Wood New, Reroof(Tear-Over B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12 lE Wood New, Reroof (Tear-Oer C Mech. Attached Insulation, Bonded Roof Cover 12-14 1F Wood New, Reroof (Tear -Over D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 15-17 1G Wood New or Reroof (Tiar-Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 18-21 1H Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 21-25 11 Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 1 26 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover 8 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 27-29 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 30-34 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 35-37 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 38-46 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 146 4A Lightweight concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 47-49 4B Lightweight concrete New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover I50 4C Lightweight concrete New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 51-53 5A Cementitious wood fiber New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 154 5B Cementitious wood fiber New, Reroof (Tear -Off) or Recover A-2 Meth. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover '55 5C Cementitious wood fiber New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover -156 SD Cementitious wood fiber New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover i56 SE Cementitious wood fiber New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 56 6A Existing gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 57-59 6B Existing gypsum Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover '59 6C Existing gypsum Reroof (Tear-0ff) or Recover C Mech. Attached Insulation, Bonded Roof Cover '60 6D Existing gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 60 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 61-65 7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover '65 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: )w Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. NEMO ETC, LLC Evaluation Report P9290.02.08-R21 for FL1654-RZ3 Certificate of Authorization d32455 a EDITION (2017) FBC NON-HVHZ EVALUATION Revision 21: 10/08/2b18 Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 65 NNEM01 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate,polystyrene, wood fiberboard, perlite,gypsum-based roof board or mineral -wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when Installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick lightweight Insulating concrete may be substituted for rigid Insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the bas I sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published Instructions. ➢ Hot asphalt (HA): Full coverage at 25-30lbs/square. ➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-Inch wide ribbons, 12-inch o.c. ➢ Millennium PG-1 Pump Grade Adhesive (M-PGS): Continuous 0.25 to 0.5-Inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (O8500): Continuous 0.75 to 1-Inch wide ribbons, 12-inch o.c. (PaceCart or Spotshot). Note: OlyBond Green may he used where O1yBond500 is referenced. D OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive & Sealants Polyset CR-20: Continuous 2.5-3.5-Inch wide ribbons, 12-inch o.c. ➢Note: When multiple layers(s)ofinsulation and/or coverboard are Installed in ribbon -applied adhesive, boardioints shall be staggered. ➢ Note: The maximum edge d/stance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Max'ilmum Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase' the MOP listings in the tables; rather if MOP listing below meets or exceeds that listed for a particularsystem in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: I ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psi (Min. 0.5-inch thick) ➢ Millennium PG-1 Pump Grade Adhesive (M-PG3): MDP -157.5 psi (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (OB500): MDP 45.0 psi (Min. 0.5-inch thick Multi -Max FA-3) D OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+GQ ), OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-Inch thick ACFoam 11) ➢ ICP Adhesives & Sealants Polyset CR-20: MOP -117.5 psf (Min. 1.0-Inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are AN51/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RA5137. Assemblies marked with an asterisk- carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. I 10. For fully bonded assemblies, the maximum design pressure for the selected assemblyshall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 1 12. For existing substrates in a bonded recover or re -roof Installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 1 13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. NEMO ETC, LLC Certificate of Authorization 032455 Prepared by: Robert Niemmen, PE-59166 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Polygiass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R21 for FL1654-423 Revision 21: 10/08/2618 Appendix 1, Page 2 of 65 Ac1 U-N NEMO I Ptc. TABLE 11; .... .. • . SYSTEM TYPE F: 1 BON . . ROOF System 'Roof Cover (Note 15) Deck (Nate 1) Pruner MDP (psf) No. !Dint Treatment Base Ply Ply Up Ply I W-170 Min. 15/32- None None SBS-SA SBS-SA, SBS- SA, SBS- -g0.0 Inch plywood TA, APP TA TA, APP TA W-171 Min. 15/32- inch plywood (Optional) PG100 None Polyflex SA Base (Optional) APP-TA APP-TA I -90.0 W-172 Min. 15/32- PG1D0 None SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- inch plywood TA, APP-TA TA, APP-TA W-173 Min. 15/32- (DpilOnal)PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SAV Plus, rolled into Elastoflex SA V Base or (Optional)SBS-SA, SBS- SBS-SA, APP-SA, SBS- inch plywood place to create continuous bond. Elastoflex SA V FR Base TA, APP-TA TA, APP-TA W 174 Min. 15/32- pOLYBRITE 745 None SBS-SA (Optional)SBS-SA, SBS- SBS-SA, APP-SA, SBS- -105.0 I inch plywood TA, APP-TA TA, APP-TA I W-175 Min. 15/32- (Optional)PGS00 Plywood joints are covered with 4-inch wide strips of Elastoflex SAV Plus, rolled into Elastoflex SA V Plus or (Optional)SBS-SA, SBS- SBS-SA, APP-SA,SBS- inch plywood place to create continuous bond. Elastoflex SA V PIus FR TA, APP-TA TA, APP-TA -135.0 W-176 Min. 15/32- (Opiianal)PG300 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Polyflex SA Base (Optional)APP-TA APP-TA -135.0 inch plywood place to create continuous bond. NEMO ETC, LLC Certificate of Authorization #32455 Prepared by: Robert Nieminen, PE-59166 6m EDITION (2017) FBC NON-HVHZ EVALUATION Polygiass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R21 for FL3654-P23 Revision 21: 30/08/2018 Appendix 1, Page 26 of 65