HomeMy WebLinkAboutEVALUATION REPORTSt. Lucie UL Evaluation Report UL ER2453-02 Issued: April 5, 2017 Visit UL'e On -Una Certifications Directory: www,Ul.comlerdirecto�� for current statua of Report. UL Category Code: ULEZ CSI MasterlsormatS DIVISION: 07 00 00 —THERMAL AND MOISTURE Sub -level 2: 07 30 00 — Steep Slope Roofing Sub -level 3: 07 31 00—Shingles and Shakes Sub -level 4: 07 3113 — Asphalt Shingles COMPANY: OWENS CORNING ONE OWENS CORNING PKY TOLEDO, OH 43659 (419)248-7060 bula wnanrrowenscomin Com/ I. SUBJECT: Asphalt Shingles CLASSICS, SUPREME, DURATION® PREMIUM, TRUDEFINITIONS DURATION®, TRUDEFINITIONS DURATIONS STORMw, TRUDEFINITIONS DURATIONS MAXm, TRUDEFINITIONS OAKRIDGES, OA, WOODCRESTS, WOODMOORS, TRUDEFINITIONS KRIDGE® DEVONSHIREm. WEATHERGUARDS HP, BERKSHIRE®, WOODSTARTS STARTER SHINGLE, STARTER STRIP PLUS, STARTER STRIP SHINGLE, AND TRI BUILT STARTER STRIP BERKSHIRE® HIP & RIDGE SHINGLES, HIGH RIDGE HIP & RIDGE SHINGLES WITH SEALANT, RIZERIDGES HIP & RIDGE SHINGLES WITH SEALANT, WEATHERGUARDS HP HIP & RIDGE SHINGLES, PROEDGES, DURARIDGETm HIP & RIDGE SHINGLES AND PROEDGES STORMS HIP & RIDGE SHINGLES 2. SCOPE OF EVALUATION N 2015, 2012, 2009, and 2006 Intematicnal Building Code S (IBC) 02015, 2012, 2009, and 2006 international Residential Code S (IRC) H [CC ES Acceptance Criteria for Quality Documentation (AC10), Dated December 2012 III ICC ES Acceptance Criteria for Altemative Asphalt Roofing Shingles (AC438), Dated March 2012 The products were evaluated for the following properties: ■ External Fire Exposure (ANSVUL790, ASTM El08) ■ Wind Resistance (ASTM 03161; ASTM D7158) a physical Properties ( ICC-ES AC438) 3. REFERENCED DOCUMENTS ® ANSIIUL790 Eighth Edition, (ASTM E108), Standard Test Methods for Fire Tests of Roof Coverings ■ ASTM D3161-13, Standard Test Method for Wind -Resistance of Steep Slope Roofing Products (Fan -Induced Method) r ASTM D7158-11, Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift Force/Uplift Resistance Method) ■ UL Subject 2375, Outline of Investigation for Hip and Ridge Shingles (UL Fire and Wind Tests) to ICC-ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438), Dated March 2012 4. USES OWENS CORNING asphalt shingles described in this report are altematives to asphalt shingles complying with Section 1507.2.6 of the 2015, 2012, 2009 and 2006 IBC and Section R905.2.4 of the 2015, 2012, 2009, and 2006 IRC, and are Class A roof coverings for new and existing roofs. S. PRODUCT DESCRIPTION OWENS CORNING asphalt shingles are roof covering materials complying with the following properties when installed as described in this report. The products are three -tab shingles, laminated shingles and hip & ridge shingles. The products are available in standard and metric sizes. Fire Classification: OWENS CORNING asphalt shingles covered under this Report have been tested for fire classification Class A in accordance with UL790 (ASTM El08). Shingles tested in accordance with UL790 (ASTM El08) qualify for use under Section 1505.1 of the 2015, 2012, 2009 and 2006 IBC and Section R902.1 of the 2015, 2012, 2009 and 2008 IRC. Wind Resistance: OWENS CORNING asphalt shingles covered under this Report have been tested for wind resistance in accordance with ASTM D3161 or ASTM D7158. Shingles tested in accordance with ASTM D3161 are classified as Class F or Class A and qualify for use under the exception to Section 1507.2.8.1 of the 2015 IBC, Section 16072.7.1 of the 2012, 2009 and 2006 IBC, or the exception to Section R905.2.4.1 of the 2015, 2012, 2009 and 2006 IRC. Shingles tested in accordance with ASTM D7158 are classified as Class H and qualify for use in locations as shown in Table 1504.1.1 of the 2015 IBC, Table 1507.2.7.1 of the 2012 and 2009 IBC or Table R905.2.4.1 of the 2015, 2012 and 2009 IRC, where the maximum basic wind speed is 150 mph (67 m/s) or less with exposure category of B or C (ASCE 7) and a maximum building height of 60 feet (18.3 m). Installation must be in accordance with Section 1507.2.7 of the 2015, 2012, 2009 and 2008 IBC or Section R905.2.6 of the 2015, 2012, 2009 and 2006 IRC, as applicable. Physical Properties: OWENS CORNING asphalt shingles covered under this Report have been tested for physical properties in accordance with AC 438. Shingles tested in accordance with AC438 qualify as an aitemative roof covering for use under Section 1507.2.5 of the 2015, 2012, 2009 and 2006 IBC or Section R905.2.4 of the 2015, 2012, 2009 and 2006 IRC. When Installed in new construction in accordance with this report and the OWENS CORNING Installation instructions, the shingles are a Class A fire classification roof covering. When the shingles are installed over existing roof coverings, the fire classification is maintained. Page 2 of 3o DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION: 06 05 23—WOOD, PLASTIC, AND COMPOSITE FASTENINGS SCANNED BY St. Lucie County REPORT HOLDER: SIMPSON STRONG -TIE COMPANY INC. 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588 EVALUATION SUBJECT: SIMPSON STRONG -TIE® HURRICANE AND SEISMIC STRAPS AND TIES FOR WOOD FRAMING ICC ICC Ire Look for the trusted marks of Conformityl "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence" !CC -ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. A Subsidiary of Cain 1S c VMS rma.ea�vGn�mom, .<iean.wo Copyright 0 2017 [CC Evaluation Service, LLC. All rights reserved. IMES Evaluation Report ESR-2613 Reissued June 2017 Revised December 13, 2017 This report is subject to renewal June 2018. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 -A Subsidiary of the International Code Counciio DIVISION: 06 00 00—WOOD, PLASTICS, AND COMPOSITES Section: 06 05 23—Wood, Plastic, and Composite Fastenings REPORT HOLDER: SIMPSON STRONG -TIE COMPANY INC. 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588 (800)925-5099 www.strongtio.com EVALUATION SUBJECT: SIMPSON STRONG -TIE® HURRICANE AND SEISMIC STRAPS AND TIES FOR WOOD FRAMING 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2015, 2012, 2009 and 2006 International Building Code® (IBC) ■ 2015, 2012, 2009 and 2006 International Residential Code (IRC) Property evaluated: Structural 2.0 USES The Simpson Strang -Tie hurricane and seismic straps and ties described in this report are used as wood framing connectors in accordance with Section 2304.10.3 of the 2015 IBC and Section 2304.9.3 of the 2012, 2009 and 2006 IBC. The products may also be used in structures regulated under the IRC when an engineered design is submitted in accordance with Section R301.1.3 of the IRC. 3.0 DESCRIPTION 3.1 General: The Simpson Strong -Tie hurricane and seismic straps and ties recognized in this report are installed to resist design forces on wood -frame construction resulting from the application of the most critical effects of the load combinations prescribed by code that include wind or seismic loads. 3.1.1 Hurricane Ties: Hurricane ties are used to anchor wood rafters or joists to wood wall plates or studs or to anchor wood studs to wood sill plates. The H6 and 1-17Z ties are formed from No. 16 gage galvanized steel; the 1-11, H2.5A, 1-13, 1-15, 1-110A, and H10-2 ties are formed from No. 18 gage galvanized steel; and the H4 tie is formed from No.'20 gage galvanized steel. See Table 1 for tie model numbers, tie dimensions, fastener schedules, and allowable loads. See Figures la and lb for illustrations of the hurricane ties recognized in this report, and Figure 1c for illustrations of installation configurations with designated allowable load directions. 3.1.2 HS24 Hurricane Tie: The HS24 hurricane tie anchors wood rafters or trusses to wood wall top plates. The HS24 connector is formed from No. 18 gage galvanized steel. See Table 2 for required fasteners and allowable loads. See Figure 2.for a drawing of the HS24 tie and a typical installation detail. 3.1.3 LTS, MTS, and HTS Series Twist Straps: The LTS, MTS, and HTS series twist straps are used to anchor wood trusses or rafters to wood wall double top plates, wood studs, woad beams, or wood rim boards. The LTS, MTS, and HTS series twist straps are formed from No. 18, No. 16, and No. 14 gage galvanized steel; respectively. See Table 3 for strap model numbers, overall strap lengths, required fasteners, and allowable uplift loads when installed with different fastener schedules. See Figure 3 for a drawing of an LTS12 twist strap and two typical MTS strap Installations. 3.11A LFTA Light Floor Tie Anchor: The LFTA light floor tie anchor is used as a floor -to -floor tension tie and is formed from No. 16 gage galvanized steel. See Table 4 for anchor tie dimensions, required fasteners, and the assigned allowable uplift load. See Figure 4 for a drawing of the LFTA connector. 3.1.5 SP and SPH Series Stud Plate Connectors: The SP1 connector fastens one edge of a wood stud to the contiguous edge of a wood sill plate, and the SP2 connector fastens to one side of a wood double top plate and to the contiguous edge of awood stud. The SP4, SP6, SP8, SPH4, SPH6, and SPH8 are 11144nch-wide (32 mm) U-shaped straps with a horizontal portion that bears against the wood wall top plates or sill plates and two vertical legs that are nailed to the edges of a wood stud. The SP and SPH connectors are fabricated from No. 20 and No. 18 gage galvanized steel, respectively. See Table 5 for SP and SPH models, connector dimensions, required Fasteners, and allowable uplift loads. See Figure 5 for drawings of the SP1 and SP2 connector, and of typical stud -to -plate connection details for the SP1, SP2, SP4, and SPH4 connectors. LCC-ESEvahmRon Reports are not to be cowntoeolm represenlingaertheliier or any other attributer not specifically addreared. nor are they to be construed E�j, t man endonemenl oflhesubJect ofthe report or a recommendation for its use there is no ivaman0• by /CCEvaluation Service. LLC, upresr or implied, as to anyfmding or olhernearer in this mpor( arm to any product cowmd by the report. Copyright ® 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 11 ESR-2613 1 Most Widely Accepted a, - _usted Page 2 of 11 3.1.6 RSP4 Reversible Stud Plate Ties: The RSP4 tie -plates are used to connect a_nominally-2-inch-wide-wood_ stud to either a top or sill plate of a wood framed wall. The RSP4 tie connector is fabricated from No. 20 gage galvanized steel. See Table 6 for required fasteners and allowable loads. See Figure 6a for a drawing of the RSP4 connector showing overall dimensions; Figure 6b for a drawing of a typical RSP4 installation connecting a wood double top plateto a wood stud; and Figure 6c for a typical RSP4 installation connecting a wood stud to a wood sill plate. 3.1.7 SSP and DSP Stud Plate Connectors: The SSP stud -to -plate connector is used to provide a positive connection between a single wood stud and the top or sill plate of the same wood wall, and the DSP stud -to -plate connector is used to provide a positive connection between a double wood stud and the wood wall top or sill plate of the same wood wall. The SSP and DSP connectors are fabricated from No. 18 gage galvanized steel. See Table 7 for required fasteners and allowable uplift loads. See Figure 7 for drawings of the SSP and DSP connectors showing overall dimensions; a drawing of an SSP installation connecting a stud to a sill plate; and a drawing of a DSP installation connecting a double wood stud assembly to a top plate. 3.1.8 HGT Heavy Girder Tiedown Brackets: The HGT heavy girder tiedown brackets are used to provide a positive connection between wood roof beams or multi -ply wood roof trusses and wood posts vertically aligned to support the end reaction of the beam or truss member. The HGT tiedown connector is a U-shaped bracket that is installed over the top chord of the roof truss having a slope from 3:12 (14 degrees) to 8:12 (34 degrees). Other components required for the connection, such as the anchor rods and hold-down or tie -down devices, that must be used to form a complete load path to resist design uplift forces from their point of origin to the load -resisting elements, that is, the vertically aligned supporting wood post, must be designed and specified by the registered design professional. The HGT tiedown brackets are fabricated from No. 7 gage steel, and are supplied with insert plates and crescent washers. See Table 8 for tiedown connector models, connector dimensions, fastener schedules, and allowable uplift loads. See Figure 8 for a drawing of the HGT-2 tiedown connector. 3.2 .Materials: 3.2.1 Steel: Unless otherwise noted, the connectors described in this report are fabricated from ASTM A653, SS designation, Grade 33, galvanized steel with a minimum yield strength, Fy, of 33,000 psi (227 MPa) and a minimum tensile strength, Fu, of 45,000 psi (310 MPa). The HTS twist straps, the SSP and DSP stud -to -plate ties, and the H2.5A hurricane tie are fabricated from ASTM A653, SS designation, Grade 40, steel with a minimum yield strength of 40,000 psi (275 MPa) and a minimum tensile strength of 55,000 psi (379 MPa). The body of the HGT heavy girder tiedown bracket is fabricated from ASTM At011. SS designation, Grade 33, hot rolled steel with a minimum yield strength of 33,000 psi (227 MPa) and a minimum tensile strength of 52;000 psi (358 MPa), and the crescent washers of the HGT bracket are fabricated from ASTM A36 steel with a minimum yield strength of 36,000 psi (248 MPa) and a minimum tensile strength of 58,000 psi (399 MPa). Base -metal thicknesses for the connectors in this report -.are-as.follows�-- --- NOMINAL THICKNESS (gage) MINIMUM BASE -METAL THICKNESS (inch) No. 3 0.2285 No. 7 0.1705 No. 10 0.1275 No. 14 0.0685 No. 16 0.0555 No. 18 0.0445 No. 20 0.0335 For Sh 1 Inch = 25.4 mm. The galvanized connectors have a minimum G90 zinc coating specification in accordance with ASTM A653. Some models (designated with a model number ending with Z) are available with a G185 zinc coating specification in accordance with ASTM A653. Some models (designated with a model number ending with HDG) are available with a hot -dip galvanization, also known as "batch" galvanization, in accordance with ASTM A123, with a minimum specified coating weight of 2.0 ounces of zinc per square foot of surface area (600 g/m2), total for both sides. Model numbers in this report do not include the Z or HDG ending, but the information shown applies. The HGT Heavy Girder Tiedown Brackets have a painted finish and may also be available with the HDG finish. The lumber treater or holder of this report (Simpson Strong -Tie Company) should be contacted for recommendations on minimum corrosion resistance of steel connectors in contact with the specific proprietary preservative treated or fire retardant treated lumber. 3.2.2 Wood: Supporting wood members to which these connectors are fastened must be solid sawn lumber, glued - laminated lumber, or engineered lumber [such as Laminated Veneer Lumber (LVL), Parallel Strand Lumber (PSL), and Laminated Strand Lumber (LSL)] having dimensions consistent with the connector dimensions shown in this report. Unless otherwise noted, supporting wood members and supported members must have an assigned minimum specific gravity of 0.50 (minimum equivalent specific gravity of 0.50 for engineered lumber), except as .noted in Table 5 for the SPH stud plate tie connectors, which provides values for which lumber members having assigned minimum specific gravities of 0.50 and 0.55 are required; and Table 7 for the SSP and DSP stud -to -plate tie connectors, which permits lumber having assigned minimum specific gravities of 0.50 and 0.43. The lumber used with the connectors described in this report must have a maximum moisture content of 19 percent (16 percent for engineered lumber) except as noted in Section 4.1. The thickness of the wood members must be equal to or greater than the length of the fasteners specified in the tables In this report, except if noted otherwise in the tables and accompanying footnotes in this report, or as required by wood member design, whichever controls. 3.2.3 Fasteners: Bolts, at a minimum, must comply with ASTM A36 or A307. Nails used for connectors,, straps, and ties described in this report must comply with ASTM F1667 and have the fallowing minimum dimensions and bending yield strengths (Fyb): ESR-2613 I Most Widely Accepted a - __usted Page 3 of 11 - FASTENERS_ NAIL —DIAMETER. _ (inch) NAIL _LENGTH— (inches) P -(Ps9 8d x 1% 0.131 ill, 100,000 8d 0.131 2% 100,000 10d x 1% 0.148 1'/z 90,000 10d 0.148 3 90,000 For 51: 1 inch = 25A mm. Fasteners used in contact with preservative treated or fire retardant treated lumber must comply with Section 2304.10.5 of the 2015 IBC, Section 2304.9.5 of the 2012, 2009 and 2006 IBC, Section R317.3 of the 2015, 2012 and 2009 IRC or Section R319.3 of the 2006 IRC, as applicable. The lumber treater or this report holder (Simpson Strong -Tie Company) should be contacted for recommendations on minimum corrosion resistance of fasteners and connection capacities of fasteners used with the specific proprietary preservative treated or fire retardant treated lumber. 4.0 DESIGN AND INSTALLATION 4.1 Design: The tabulated allowable loads shown in this report are based on allowable stress design (ASD) and include the load duration factor, Co, corresponding with the applicable loads in accordance with the National Design Specification® for Wood Construction (NDS). Tabulated allowable loads apply to products connected to wood used under dry conditions and where sustained temperatures are 100°F (37.8°C) or less. When products are installed to wood having a moisture content greater than 19 percent (16 percent for engineered wood products), or when wet service is expected, the allowable loads must be adjusted by the wet service factor, CM, specified in the NDS. When connectors are installed in wood that will experience sustained exposure to temperatures exceeding 100OF (37.80C), the allowable loads in this report must be adjusted by the temperature factor, Ct, specified in the NDS. Connected wood members must be analyzed for load - carrying capacity at the connection in accordance with the NDS. 4.2 Installation: Installation of the connectors must be in accordance with this evaluation report and the manufacturers published installation instructions. In the event of a conflict between this report and the manufacturers published installation instructions, this report governs. 4.3 Special Inspection: 4.3.1 Main Wind -farce -resisting. Systems under the IBC: Periodic special inspection must be conducted for components within the main wind-farce-resisfing system, where required in accordance with Sections 1704.2 and 1705.11 of the 2015 IBC, Sections 1704.2 and 1705.10 of the 2012 IBC, Sections 1704 and 1706 of the 2009 IBC, and Section 1704 of the 2006 IBC. 4.3.2 Seismic -force -resisting Systems under the IBC: --Periodic—special--inspection--must --be—conducted—for--- - components within the seismic -force -resisting system, in accordance with. Sections 1704.2 and 1704.12 of the 2015 IBC, Sections 1704.2 and 1705.11 of the 2012 IBC, and Sections 1704 and 1707 of the 2009 and 2006 IBC. 4.3.3 Installations under the IRC: Special inspections are normally not required for connectors used in structures regulated under the IRC. However, for components and systems requiring an engineered design in accordance with IRC Section R301,.pedodic special inspection must be in accordance with Sections 4.3.1 and 4.3.2 of this report. 5.0 CONDITIONS OF USE The Simpson Strong -Tie Hurricane and Seismic Straps and Ties described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The connectors must be manufactured, identified and installedin accordance with this report and the manufacturers published installation instructions. A copy of the instructions must be available at the jobsite at all times during installation. 5.2 Calculations showing compliance with this report must be submitted to the code official. The calculations must be prepared by a registered design professional where required by the statues of the jurisdiction in which the project is to be constructed. 5.3 Adjustment factors noted in Section 4.1 and the applicable codes must be considered, where applicable. 5.4 Connected wood members and fasteners must comply, respectively, with Sections 3.2.2 and 3.2.3 of this report. 5.5 Use of connectors with preservative or fire retardant treated lumber must be in accordance with Section 3.2.1 of this report. Use of fasteners with preservative or fire retardant treated lumber must be in accordance with Section 3.2.3 of this report. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Joist Hangers and Similar Devices (AC13), dated February 2017. 7.0 IDENTIFICATION The products described in this report are identified with a die -stamped label or adhesive label indicating the name of the manufacturer (Simpson Strong -Tie), the model number, and the number of an index evaluation report (ESR-2523) that is used as an identifier for the products recognized in this report. ESR-26131 Most WidelyAccepted a, _ iysted Page 4 of 11 TABLE1—HURRICANE TIES - - ---FASTENERS.— "��--�'---"- (Quantity -Type) ' ` �" `-"--A6l:OWABLE�EOAOS''T -` - ----- � -- - (lbs). MODEL NO: - - ._ To Rafter To Plates -. To Stud .. Connection. Configurations a . U lift'' P Cm=1.6 - Lateral?-7 C,=1.6• ' F, Fo H1 6-8dx 1% 4-8d — 1 545 510 190 H10A 9-10d x V/2 9-_10d x 1'/z — 1,040, '565 285 H10-2 6-10d 6-10d — 655 430 355 ' •H2.5A =5--8d ., '.i .- S-8d. :";' -...-.. - .. 2 --- 565' - 910 - " 1110:. H3 4-8d 4-8d — 435 210 170 HS 4-8d - 4-8d — 440 100 225 — 4-8d 4-8d 3 330 — — H4 "d 4-8d — 4 330 140 175 _•146 8-8d 8--8d 5 t230 — — ' H7Z 4-8d 2-8d 8-8d 6 830 410 — For SI: 1 inch = 25.4 mm, 1 Ibs = 4.45 N. 'Allowable loads are for one anchor installed to a minimum nominal 2xsupported and minimum nominal 2x supporting wood member. A rafter minimum actual thickness of 2% Inches must be used when framing anchors are installed on each side of the rafter and on the same side of the plate. 'Allowable simultaneous loads in more than one direction on a single connector must be evaluated as follows: Design Uplift / Allowable Uplift + Design Lateral Parallel to Plate / Allowable lateral Parallel to Plate + Design Lateral Perpendicular to Plate / Allowable Lateral Perpendicular to Plate 5 1.0. The three terms in the unity equation consider all possible forces that the hurricane tie maybe designed and installed to resist. The number of terms that must be considered for simultaneous loading is determined by the registered design professional and is dependent on the method of calculating wind forces and the assumed load path that the connector is designed to resist. '"Connection Configurations" shown in Figure tc (next page) indicate the load directions F, and Fi, and are details showing connector installations on the outside of the wall for clarity. Installation on the inside of the wall is acceptable to achieve the tabulated allowable loads. "Connections In the same area (i.e. truss to plate connector and plate to stud connector) must be on installed on the same side of the wall to achieve the tabulated allowable uplift loads and ensure a continuous load path. sAloowable uplift loads have been Increased for wind or earthquake loading, and no further increase is allowed. Allowable loads must be reduced when other load durations govem. oAloowable lateral loads in the F, direction must not be used to replace diaphragm boundary members or nailing or replace solid blocking required by code to laterally support the ends of joists/rafters. 'Additional shear transfer elements must be considered the connector installation induces cross grain bending or tension of the truss or rafter members. 16 oHm� 0 0 4�0 23,16 a m H1 tit H2.SA H3 FIGURE la —HI, H2.5A, AND H3 HURRICANE TIES ESR-2613 [ Most Widely Accepted a, usted Page 5 of 11 H5 H6 H6 Stud to Double Tol Plate Installation H7Z FIGURE 1b—H4, H5, H6, H7Z, H10A AND H10-2 HURRICANE TIES t% ❑j HI Installation (H10A and 1-170-2 similar) I H4 Installation H6 Stud to Band Joist Installatia H2.5A Installation (Nails Into both top plates) (H3 and HS similar) 0 F, H4 lnstalla0on (Nails Into upper top plate) UwaminMam Vahm Ad nalb a1sslGe ollaosa tram r@ r, �'-bVaV Val4 Imo Vlatee. Nio F\Voids 6 coos H7Z Installation FIGURE 1c—CONNECTION CONFIGURATIONS OF HURRICANE TIE INSTALLATIONS SPECIFIED IN TABLE 1 ESR-2613 I Most Widely Accepted at vsfed Page 6 of 11 TABLE 2—HS24 HURRICANE TIE F}CS7ENERS'(Quantity-Type) T ALLOWABLE LOADS(lbs); Co=1.6 MODEL' . 'NO. • To Rafter or Truss To Double Top Plate. - UPlift' Lateral''•'' ' _ Fr _ F21 8-8d x 1r/2 & 2-8d (slant) 8-8d 605 645 1,100 HS24 8-8d x 1 % 8-8d 625 625 680 For SI: 1 inch = 25.4 mm, 1 Ibs = 4.5 N. "Slant* nailing refers to 8d common nails installedas toenails on each side of the connector. The nails must be driven through the connector at an angle approximately 30' with the rafter/truss member with the nail penetrating through the rafter/truss member into the wood double top plate. The uplift loads have been Increased for wind or earthquake loading. No further increase is allowed. Allowable loads must be reduced when other load durations govern. 'Allowable lateral loads In the Fi direction must not be used to replace diaphragm boundary members or nailing or replace solid blocking required by code to laterally support the ends of joists/rafters. 'Additional shear transfer elements must be considered the connector Installation induces cross grain bending or tension of the miss or rafter member. 'Fj load direction is parallel to plate, and F2 load direction is perpendicular to plate. 1�• eso • e • • HS24 Dimensions ae • 23% U.S. Patents �y+ •� 5,603,580 • HS24 Installation and Allowable Load Directions FIGURE 2—HS24 HURRICANE TIE ESR•2613 I Most Widely Accepted a, usted Page 7 of 11 TABLE 3—LTS, MTS, AND HTS TWIST STRAPS J TWIST SERIES •' ., 'MODEL NO. ,' STRAP' LE(in) '-" TOTAL QUANTITY OF FASTENERS'' . ALLOWABLE UPLIFT L'OADS'•':(Ibs), - When Installed .with 10d,Common Nails- When Installed, with tOdxl'Iz . Common Nails- - When Installed with 10d . Commorr.Natls Wheminstalledlwith- 10dxV CommowNalls Ca=1.6'' _ CD='11.6, LTS° LTS12 12 12 12 660 800 LTS16 16 LTS18 18 LTS20 20 _ MTS'- - MTS127. '.'. 12 -.,• :, _ -. 14'. ,. .14 -' ... ., - 990 990 ,. MTS16 '16 =- MTS18'. .18' MTS20.•'. 20 MTS30; 30 HTS16 16 16 16 1,310 1,310 HTS' HTS20 20 20 24 1,310 1,310 HTS24 24 HTS28 28 HTS30 30 HTS30C 30 For SI: 1 inch = 25A mm, 1 Ibs = 4.45 N 'Half of the fasteners must be installed on each end of the strap to achieve the allowable uplift load. Tabulated allowable uplift loads must be selected based on duration of load as permitted by the applicable building code. 'Tabulated allowable uplift loads have been increased for wind or earthquake loading. No further increase is allowed. Allowable loads must be reduced when other load durations govern. °Each model of the LTS and MTS twist strap series (except for the MTS30) has more nail holes than the minimum quantity of nails specified in the table. 5HTS30C has the.twist in the center of the strap length 1'Typ. 11/a' LTS12 (MTS and HTS Similar) Typical MTS Installation — Rafter to Stud FIGURE 3—TWIST STRAPS Typical MTS Installation Truss to Double Top Plate ESR•2613 I Most Widely Accepted i . dusted Page 8 of 11 TABLE 4—LFTA LIGHT FLOOR TIE ANCHOR' LFTALANCHOR DIMENSIONS (in) .• FASTENERS'_ • (Ouanllty. Type) ALLOWABLE TENSION'LOAD'14'(Ibs) 11 CD =, 1.6' MODEL NO. • Strale Width (W) Clear Span Overall Length (L) LFTA 1 2'la J 17 38% 1 16-10d Common 1,325 For SI: 1 inch = 25.4mm, 1 Ibs = 4.45 N. 'The LFTA anchor is used to transfer tension forces between vertically aligned wood studs across floor framing with floor joists having a maximum nominal depth of 12 inches. Half of the fasteners must be installed on each end of the strap to achieve the allowable uplift load. Tabulated allowable uplift loads must be selected based on duration of load as permitted by the applicable building code. 4Tabulated allowable uplift loads have been increased for wind or earthquake loading. No further increase is allowed. Allowable loads must be reduced when other load durations govern. FIGURE 4—LFTA LIGHT FLOOR TIE ANCHOR ESR-2613 I Most Widely Accepted a' 'Usted Page 9 of 11 TABLE S—SP AND SPH STUD PLATE TIES ' - -CONNECTOR DIMENSIONS,(in) - ` ,; -FASTENERS',—.`-'`--ALLOWABLE ,•, (Quantity -Type), .; UPLIFT LOAD82-"—,- -_ - '(Ibs) CONNECTOR • SERIES `MODEL' '• No. • • I .(L) . To Stud To�Plate .• - S:G:-= 0.50 - -0:55� .S.G:- SP1 - - 6-10d 4-10d 555 555 SP2 — — 6-10d - 6-10d 1,010 1.010 SP4 3'/16 T!a 6-10d x 1 % — 825 825 6-16d x 2'!2 — 850 850 SP SP6 5°/is 72/< 6-10d x 11/2 — 825 825 6-16d x 2'/2 — aso aso SPB 7s/�s 95/16 6-10d x 11/2 — 825 825 6-16d x 2% — 850 850 .. •, _:. . SPH4 ' 3'/rs ' ' 81/a �10-10d�x 1'/z. '— — - 1,040 - 12-10d7x 1%, • • 1;280i _ . 1',175 SPH ' SPH6 59/is 9'/a 1 10-10d'x 1'/z — — '� 1,040 `I2-10d x 1'/z — 1,280 1L415 • SPHB •7slis 8a/a,.. :11 _ -1,175 .12-10d.:c1'/i• 1,280 - 1,416 For SI: 1 inch = 25.4 mm, 1 Ibs = 4.45 N. 'For Models SP1 and SP2, one 10d common stud nail must be installed as a toenail. It must be driven through the connector at an angle approximately 30° with the stud with the nail penstraling through the stud into the wood sill plate. (See detail on this page entitled 'SP1 Nailing Profile..") 2Tabulated allowable uplift loads must be selected based on duration of load as permitted by the applicable building code. 'Tabulated allowable uplift loads have been increased for wind or earthquake loading. No further increase Is allowed. Allowable loads must be reduced when other load durations govern. °Allowable uplift loads are given for wood assemblies consisting of lumber having an assigned specific gravity (S.G.) of 0.50, such as Douglas fir-4arch, and 0.55, such as southern pine. �2x7 I Aw L SP11SP2 Typical SPH4 Installation: Stud to Wood SIII Plate (SP4 Similar) SP2 Installation: SP1 Nailing, Profile Stud to Double Top Plate SP1 Installation: Stud to Sill Plate Typical SP4 Installation: Double Top Plate to Stud (SPH Similar) FIGURE S—SP AND SPH STUD PLATE TIES ESR-2613 I Most Widely Accepted a', _ 'vsted Page 10 of 11 TABLE 6-RSP4 REVERSIBLE STUD PLATE CONNECTOR' .. ,., —. . ' ,(Quan ity Type) .... ALLOWABLE' LOADS''z,(Ibs) Co = CC '-- - MODEL • NO•'. To Stud :To.Plate _ - �ConnectiowConfigurallonl" Uplift - r 'Laterals. � F: _ Fs:.. F2SP4 4�d x 1 /z 4-Sd x 1 /z Stud to Double Top Plate 390 165 245 Stud to Sill Plate 245 165 225 For SI: 1 inch = 25A mm, 1 Ibs = 4.45 N. 'Refer to Figure 6a for overall dimensions of the RSP4 plate connector. TTabulated allowable loads must be selected based on duration of load as permitted by the applicable building code. 'Tabulated allowable loads have been Increased for wind or earthquake loading. No further increase is allowed. Allowable loads must be reduced when other load durations govern. 'Refer to Figure 6b and 6o for connection configurations. sF, load direction is parallel to plate, and Fz load direction is perpendicular to plate. 11 1 c o o a EII; 0 FIGURE 6a-RSP4 STUD PLATECONNECTOR DIMENSIONS FIGURE 6b-RSP4 INSTALLATION: FIGURE 6o-RSP4 INSTALLATION: STUD TO DOUBLE TOP PLATE STUD TO SILL PLATE U.S. PATENT 5,697,725 TABLE 7-SSP AND DSP STUD PLATE TIE CONNECTORS FASTENERS ALLOWABLE UPLIFT LOAD$'•z'z'"'(Ibs) " MODEL . '_• (QuantityTl/Pe).. .; • . ,: �. ,, - ;Co=1.6, ., :NO. Studs ,,'Double Top Plate • '.-. Sill Plate'' Double Top Plate SiI1)Plate --- - B.G. = OS0' _ S:G..= 0:50' - &G. = 6.43� SSP 4-tOd x 1'/z 3-10d x 1'/2 - 330 - - - 1-10d x 02 - 395 310 3-10d - 410 - - 4 10d - 1-10d - 430 400 DSP 6-10d:x 1'/2 - - 730, T - - '2-10d x 1%- - 620 '515, For SI: 1 inch = 25.4mm, 1 Ibs =4.45 N. 'Tabulated allowable uplift loads have been increased for wind or earthquake loading no further increase allowed. Reduce loads when other load durations govem. 'When cross -grain bending or cross -grain tension cannot be avoided, mechanical reinforcement to resist such forces should be considered. 'For Sill Plate allowable uplift loads, all round nail holes in the connector must be filled with the specified quantity and type of nails. °For Double Top Plate allowable uplift loads, all round and triangular nail holes the tie connectors must be filled with the specked quantity and type of nails. Nlt;fil �14b� 6111,e N h—?.iy • SSP DSP U.S. Patent U.S. Patent 7,065,932 7,065,932 7,356,973 7,356,973 SSP Installation: Single Stud to Sill Plate FIGURE 7-SSP/DSP STUD PLATE TIES DSP Installation: Double Stud to Double Top Plate ESR-2613 I Most Widely Accepted'. rusted Page 11 of 11 TABLE 8—HGT HEAVY GIRDER TIEDOWN CONNECTORS'" ` MODEL" a� NO.• HGTCONNECTOR , , � WIDTH_ �� -. OM ' (in.) DISTANCE BETWEEN', THREADED RODS (on center). .,(inches) FASTENERS (Quantity —Type)'. -- ALLOWABLE : UPLIFT LOADS',, • Co=116 ' _ (Ibs); -Threaded Roilr•e To Multiply Truss - • HGT-2 35/„ 04 2-5/,- Dla. 16-10d 10,345 'HGT-3 4'5/„ 7'/e 2-5/s",Dias• "._ 16-10d _ --10,440 HGT-4 69/16 9 2—s/e Dia. 16-10d 11.395 For SI: 1 inch = 25Amm, 1 Ibs = 4.45 N. 'The HGT connector can accommodate top chord slopes from minimum 3:12 (14°) to maximum 8:12 (34°) and are provided with crescent washers for sloped top chard installations. 'Ail elements of the tie -down assembly (multi -ply trusses, vertically aligned wood studs/posts, and the full -height threaded rods) must be designed to resist applied loads. 'The HGT-2, HGT-3, and HGT-4 connector attaches to the heel joint of a two-ply, three-ply, and four -ply wood truss, respectively, where each qthickness Is nominal 2 inches. When the HGT-3 is used with a two-ply truss, shimming is required, and the shimming material must be similar (thickness and grade of lumber) as the truss member material. Additionally, the entire assembly must be designed by a registered design professional to act as. one unit. 'Tabulated allowable loads must be selected based on duration of load as permitted by the applicable building code. 6The uplift loads have been increased for wind or earthquake loading with no further increase is allowed. Reduce loads when other load durations govern. 'Full -height threaded rods are shown in Figure 8 for illustration purposes only, as one method of transferring the design load from the HGT connector to the foundation. The threaded rod material specifications must be specified by the registered design professional. aTwo LBP 5/,inch washers must be installed on top of each crescent washer. LBP washers and crescent washers are required. Crescent washers are supplied with the connector. LBF1%washers are available from Simpson Strong -Tie Company, and are 2-inch square by 9/winch thick galvanized steel washers with a center bolt hole to accommodate a 5/,-inch diameter threaded bolt/rod. HGT-2 (HGT-3 and HGT-4 similar) Install two LBPe'e washers on top of each crescent washer (total four W washers) for wood installation. All washers and crescent washers are required. Crescent washers are supplied. Typical HGT-3 Installation with full height threaded rod. The design of the threaded rod, Including any necessary hardware or shrinkage compensating devices, is outside the scope of this report. FIGURE 8—HGT HEAVY GIRDER TIEDOWN CONNECTOR ICC EVALUATION SERVICE Certification of Independence for Evaluation ICC Evaluation Service, LLC Western Regional Office 3060 Saturn Street, Suite 100 Brea, CA 92821 t: 1.800.423.6587, ext. 1 f: 562.695.4694 w Jcc-es,org 1) ICC Evaluation Service, LLC, does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products for which evaluations are issued. 2) ICC Evaluation Service, LLC, is.not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3) ICC Evaluation Service, LLC, does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products for which reports are being issued. 4) ICC Evaluation Service, LLC, does not have, nor will it acquire, a financial interest in any other entity involved in the approval process of the product. 'l t-tls - l ts- Shahin Moinian, President ICC Evaluation Service, LLC SCANNEIF (TERIOR RESEARCH & DESIGN, I.I.C. BY CertiRcate of Authorization U95o3 ERD St. Lucie County 353 CHRISTIAN STREET, UNIT#13 OXFORD, Ci 06478 (203)262-9245 Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404.7820 Evaluation Report 03794O.02A2.R8 FL10674-R13 Date of Issuance: 02/06/2012 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building. Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited quality Assurance Agency noted herein and FBC 1507:2.7.1 / R905 2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced quality Assurance documentation changes. Trinity]ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation.Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. - Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59266, Florida DCA ANE1983 Thefacsimile seal appearing was authorized by Robert Nleminen, P.E. on 10/09/2017. This does not serve as an electronically signed document CERTIFICATION OF INDEPENDENCE: 1. Trinity I ERD does not have, nor does It intend to acquire or will It acquire, a financial Interest in any company manufacturing or distributing products It evaluates. 2. Trinity) ERD Is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P:E. does.not have nor will acquire, a financial Interest in any company manufacturing or distributing products for which the evaluation reports are being Issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the product. 5. This Is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING SYSTEMS EVALUATION: 1. SCOPE: TPJN8TYI ER® Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM-D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2:6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Emily.Examination Reference Date UL LLC (CER9626) Physicals Si Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CE0626) Physicals &,Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9626) Physical Properties 06CA20263 04/18/2006 UL LLC(TST9628) Wind Resistance IICA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 07/01/2014 UL LCC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (T5T9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade.(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp. 05/16/2020 4. PRODUCT. DESCRIPTION: 4.1 Asphalt hingles: 4.1.1 Classic .and Supreme are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire"' are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration., TruDefinition Duration, Duration* Premium Cool, TruDefinition Duration* Designer Color Collection, TruDefinition Oakridge�, Oakridge and WeatherGuard* HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip & Ridge Shin -[as. 4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and Duraltidge"' Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity]ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report, refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report O37940.02.ILR8 Cert1/kore ojaurhoroatlan e5503 a EDITION (2017) FBC NON-HVHZ EVALUATION FUOSMR13 Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017 Page 2 of 8 v TPJNI PIER® 5_4 Wind.Classifiration: 5.4.1 All Owens Corning; asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to V„d = 150 mph (Vnn = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tab !as and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to V,,d =15o mph (Volt =194 mph). Refer to Section 6 for installation.requirements to meet:this.Wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C, as defined in FBC 1609.4.3, and a.mean roof height of 60 feet or less. Calculations.by a qualifeii design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit In accordance with F.A.C. Rule 611320-3. 6. INSTALLATION: 6_i Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule61G20-3, per FBC 1507.2.3,1507.2.4 or R905.2.3. 6_2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply With the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R90S.2.6, with the following exceptions: ➢ Berkshire shingles require minimum five (5) nails per shingle. D WeatherGuard' HP shingles require minimum six (6).nails per shingle. ➢ De6onshirer" shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter; Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published Information on wind resistance and installation limitations. 6.2.2 Fasteners shalt be in, accordance with the manufacturer's published requirements, but not less than FBC 1567.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the ,of slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures'belowfor details. 6.2.5 Minimum Nailing — StarterStrip Shingle and Starter Strip Plus: Exterior Research and Design, U.C. Evaluation Report 037940,02.12-RS eem/rwee o)Aod,arkadan /l9503 6'" EDITION (2017) FBC NON-WK EVALUATION FL10674•1113 Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017 Page 3 of 8 6.2.6 Minimum Nailing— Classice&Supreme: Ampars v m;' 6.2.7 Minimum Nailing — Berkshire®: Standard Fastening Pattern �TRJNITYJERD named A gisplil' s pV �.r<rirJ�l\T7T,"ii Yam'® �Qa,� i &ahntet0p - fellnWetltsior Cie air T 2' AsyM1eM roo0i0oement CaronmOuuWotlaesteCc Mansard or Steep Slope Fastening Pattern Pattern EUMdor Research and Design, LI.C. Evaluation Report 037940.02.12•Ra ceropcate GrAvthorhotion 09503 dm EOmON)2017)FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revisl0n 8: 10/09/2017 Page 4 of 8 6.2.8 Minimum Nailing —Devonshire"': 5518' wpm Espodd0n't45brepulp ♦v 6.2.9 Minimum Nailing — Duration®, TruDeflnitionIs Duration, Duration® Premium Cool & TruDeflnition Duration :Designer Color,Collection: b-Nall Fastening Pattern Pattern Exterior Research and Design, LLC. Evaluation Report 037940.02.12-Re Ce.rtnaro ofAurhodkodan 05503 6'"EDMON 12017)FBC NON-NVFQ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017 Page 5 of 8 6.2.1 Minimum Nailing —TruDefinition Oakridge®, OakridgeO: C NaIIPdtom EsgjtsiM:4 claws ncanoar0 Fastening Pattern TRINITYi ER® 6-Nall-Fastening Pattern FnLning rm elopn.GMtBrTh2n 2112 . Yi4AT�a1 p it ws• sar � I .. Iaa1.OpY y11y11N � Cam! Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing — WeatherGuard® HP: ilnpls'f1drHlwo grer�.en,7r - iY:i r fii .. Exterior Research and Design, LLG Evaluation Report 037940.02.12-R8 Certylwte ofaumonmuan 89509 6'" EDITION (2017) FBC NON-HVH2 EVALUATION F1.106741113 Owens Coming Asphalt Roof Shingles Revision 8: 10/09/2017 Page 6 of 8 L. Hip & Ridge Shingles, \11iTR N1TYIERD 6:3.1 Installation of Berkshlre Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of DuraRidge"' Hip & Ridge Shingles shall comply with the Owens Corning current published Instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6,or.R905.2:5. Staples are not permitted. 6.3.3 Minimum Nailing— Berkshire® Hip & Ridge and High Ridge: 6.3.4 Minimum Nailing— WeatherGuard® HP Hip and Ridge: Plpipbgb'yb /—WRibn ' NoIY Exterior Research and Design, U.C. Evaluation Report 037940.02.12.R8 O:rtPcnre QfAuthodrndon 05503 6'" EDITION (2017) FBC NON•HVW EVALUATION FL1OS74•R33 Owens coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 T FF 6.3.5 Minimum Nailing - ProEdge Hip & Ridge, Shingles: Pnevemrig ' I Btonderd Win .d Dt_inotlon �ajod 6tdp - f Featening Pattam 6-Eipoewit 6.3.6 Minimum Nailing — DuraRidge'" Hip &.Ridge shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructionsfor3helrminimum requirements. ptnnitii avrfiro,pbanirtmT, 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R965.2.6.1. 8. BUILDING. -PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING -PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUAuTy AssuRANCEENTITy: ULLLC—QUA9625;(631)546-2458;Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report 037940.02.12.RB CerdPtube o)Authortrodon 09503 6'" EOMON 12017) FBC NON•HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 8 of 8