SECTION 1626
HIGH -VELOCITY HURRICANE ZONES - UNIFORM PERMIT APPLICATION
Florida Building Code 6th Edition (201
High -Velocity Hurricane Zone Uniform Permit Application
INSTRUCTION PAGE
RECEIVED
JAN 15 2019
ST. Lucie County, Permitting
COMPLETE THE NECESSARY SECTIONS OF
THE UNIFORM ROOFING PERMIT
APPLICATION FORM AND ATTACH THE
REQUIRED DOCUMENTS AS NOTED BELOW
SCANNED
Sp LuCBCOtjnt,,
Roof System
Required Sections of the
Permit Application Form
Attachments Required
See List Below
Low Slope Application
A,B,C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150
A,B,C
4,5;6,7
..—.---�P--•- ,
AspWtic.Shingles ,
_ -" A,%D
Concrete or Clay Tile
A,B,D,E
1,2,3,4,5,6,7
Metal Roofs
A,B,D
1,2,3,4,6,6,7
Wood Shingles and Shakes
A,B,D
1,2,4,5,6,7
Other
As Applicable
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED:
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
ZeBsign Calculations per Chapter 16, or If Applicable, RAS 127 or RAS
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing' Only)
7.
Any Required Roof Testing/Calculation Documentation
FLORIDA BUILDING CODE 6th Edition (2017) —BUILDING
5.31
ROOF ASSEMBLIES AND ROOFTOP ST, 'a'URES
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section A (General Information)
Master Permit No. _ Process No.
Contractor's Name 7T -4 S h ems. tl i
Job Addresb,, 734 (iCT�.IL: I llr'r � fP
❑f Low Slope
I.�sphaltic Shingles
❑ Mechanically Fastened Tile
❑ Metal Panel/Shingles
❑ Prescriptive BUR-RAS 150
❑ Mortar/Adhesive Set Tile
❑ Wood Shingles/Shakes
ROOF TYPE
Y,New Roof Q Repair 13 Maintenance f3 Reroofing 171 Recovering
ROOF SYSTEM
INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) �— Total (SF) I0�0
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of
parapets. S w _ _ — _ - N
15.32 FLORIDA BUILDING CODE 6th Edition (2017) — BUILDING
ROO iEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section C Low Slope Application Surfacing:
Fill in specific roof assembly components
and identify manufacturer Fastener Spacing for Anchor/Base Sheet Attachment:
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval No.:
Design Wind Pressures, From RAS 128 or Calculations:
Pmax1: Pmax2: Pmax3:
Max. Design Pressure, from the specific Product
Approval system:
Deck:
Gauge/Thickness:
Anchor/Base Sheet & No, of Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insulation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheet(s) & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Field: _" oc @ Lap, # Rows _ @ _" oc
Perimeter: _" oc @ Lap, # Rows _ @ oc
Corner: _" oc @ Lap, # Rows _@_ 11 oc
Number of Fasteners Per Insulation Board:
Field_ Perimeter_ Corner
Illustrate Components Noted and Details as
Applicable:
Woodblocking, Gutter, Edge Termination, Stripping, Flashing,
Continuous Cleat, Cant Strip, Base Flashing, Counter -
Flashing, Coping, Etc.
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material Thickness, Fastener
Type, Fastener Spacing or Submit
FLORIDA BUILDING CODE 6th Edition (2017) —BUILDING 15.33
ROOF ASSEMBLIES AND ROOFTOP S1 'rURES
)rtaa tsuiming code Edition 6th Edition (2017)
High -Velocity Hurricane zone Uniform Permit Application Form.
Section D (Steep Sloped Roof System)
Roof System Manufacturer: NZ I q
Notice of Acceptance Number:
I5-1 IO2.63
ro 4
Minimum Design Wind Pressures, If Applicable (From RAS 127 or
Calculations :
�1: 33 P2: S� P3:
Steep Sloped Roof System Description
Deck Type:
Type Underlayment: �jy(I
Ro Slope: rj,
12 Insulation:
A sherd.
Fire Barrier: �j 1 Shed
Ridge VentilI TA,
Fastener Type & Spacing:
�l / n Shank <, 1�" aP
Adhesive Type:ooTm�m
Type Cap Sheet: P:d � �{ 5 h e
t
Mean Rocf Height: I! Roof Covering:
Type & Size Drip b st` I. a „
Edge:
aalur�ntzed a"xa"
JJ drib edges
15.34 FLORIDA BUILDING CODE 6th Edition 2017 —BUILDING
ROOT` .;EMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 6th Edition (2017)
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section E Tile Calculations
ForMomentbased rile systems, choose either Method 1 m2.Compare the valuesfor Mrwith the values from Mf. Ifthe Mfvalues arestut than or
equal to the Mr values, for each area of the roof, then the file attachment method is acceptable.
Method I "Moment Based Tile Calculations Per RAS 127"
(PI:—x L——)-Mg.—=Mr, — Product Approval Mf_
(P:—x3 =
2—)-Mg:—_=Mr2— Product Approval Mt—
(P3:—x L—=—)- Mg: ,—=1d
r3— Product Approval Mf—
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance(Mr) Frnm Tabu R,lnw .— ..... .______...
_.. r-
Mr required Moment ResistaQce*
Mean Roof Height
Roof Slope �.
1s
20'
260•2:12
34.4
36.5
3&.23:12
32.2
34.4
36..84:12
30.4
32.2
33..35:12
28.4
30.7
31..96:12
26.4
28.0
29..47:12
24.4
25.9
27.1.0
'Must be used in conjunction with a Est of moment based file systems endorsed by the Bmward County Bond of Rules and Appals.
For Uplift based tle systems use Method3. Compared the values for with the values for Fr. If the F values Or, gree,ttin, or equal to the Fr values,
for each area of the roof, then the rile Machment method is acceptable.
Method 3 "Moment Based Tile Calculadons Per RAS 127"
(Pl:—xL—=_xw:= -W:_x ws0 _—Fr
— I _ Product Approval F'
(P2:_x L_=_xw:=_)-W:_x cos0_=Fr2_ Product Approval F.
(P�: xL = xwe= t_W. .....
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
PI or P2 or P3
RAS 127 Table I or by an engineering analysis prepared by PE based on ASCE 7
Mrau Roof Height
H
lob Sim
Roof Slope
B
lob Site
Aerodynamic Multiplier
2
Product Approval
Restoring Moment due to
Omviry
Mg
Product Approval
Attach ra m Resistance
Mf
Product Approval
Required Moment Resistance
M,
Calculated
Minimum Attachment
Resistance
F
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Trle Weigh
W
Product Approval
Tile Dimensions
L=length
W =width
Product Approval
All calculations must be submitted to the building official at the time of permit application. _
FLORIDA BUILDING CODE 6th Edition (2017) —BUILDING 15.35
SECTION 1524 - HIGH VELOCITY HURRICANE ZONES
REQUIRED -OWNERS -NOTIFICATION -FOR -ROOFING -CONSIDERATIONS
1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with
the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of
the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing
system installations. Additionally, the following items should be addressed as part of the agreement between the
owe d the contractor. The owner's initial in the designated space indicates that the item has been explained.
1. Aesthetics -Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone)
are he purpose of providing that the roofing system meets the wind resistance and water intrusion performance
standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic
issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of
agreement between the owner and the contractor.
2. Renafling Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed
in ordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building
Cade, Building. (The roof deck is usually concealed prior to removing the existing roof system).
3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units
,nhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should
occupants of adjacent units of roofing work to be performed.
4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be
ed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail
penetrations of the underside of the decking may not be acceptable. The provides the option of maintaining this
Mt0atto
nce.
5. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause
pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and
may require the review of a professional structural engineer. Ponding may shorten the fife expectancy and
performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is
r ed. Ponding conditions should be corrected.
. Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded
fro buildup of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow
scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the
ry rements of Chapter 15 and 16 herein and the Florida Building Code, Plumbing.
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of
th tural assembly (the building itself). The existing amount of attic ventilation shall not be reduced.
Exception: Attic spaces, designed by a Florida licensed engineer or registered architect to eliminate the attic
venting, venting shall not be required.
COMMENTS:
1�
ner glzjgnature Date
Contractor's Signature
City of Plantation Rev. 03/15/12