--- - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: TUBITO- PAYNE GUEST HOUSE
Builder Name: IF-LESE oWOUS al
Street: 57o3 OLEANDERAVENUE
Permit Office: STLUCIECOUNTY
n1
SCANNED
City, State, Zip: FORT PIERCE, FL,
Permit Number.
Owner.-ruenjj
Jurisdiction: ST LUCIE COUNTY
BY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 B't Lucie COurlty
1. New construction or existing New (From Plans)
9. Wall Types (1144.0 sgfL)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Ext Insul, Exterior
R=4.1 1144.00 ft2
b. N/A
R= fN
3. Number of units, it multiple family 1
c. N/A
R= fl2
4. Number of Bedrooms 1
d. NIA
R= ft2
5. Is this a worst case? No
10. Ceiling Types (750.0 sgft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 750.00 ft2
6. Conditioned Floor area above grade (ft2) 750
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= 112
11. Ducts
R f6
7. Windows (116.0 sgft.) Description Area
a. Sup: Attic, Rat Attic, AH: Attic
6 125
a. U-Factor: SgI, U=0.65 116.00 ft2
SHGC: SHGC=0.25
b. U-Factor: NIA ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
18.8 SEER:16.00
c. U-Factor. N/A ft2
SHGC:
13. Heating systems
kBtLdhr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 1.500 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (750.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 750.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.155 Total Proposed Modified Loads: 31.54
PASS
Total Baseline
Loads: 36.41
I hereby certify that the plans and specifications covered by
Review of the plans and
FSHE S79T
this calculation are in compliance with the Florida Energy
specifications covered by this
O
Code.
calculation indicates compliance
gar;°6
with the Florida Energy Code.
F rrn�rs..'•o •:i e?',i.••`=�o O�
PREPA D
Before construction is completed
Ty.
DATE:
this building will be inspected for
compliance with Section553.908
..• '.c.
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy C �a.
Wy t1~�
OWNER/AGENT- /
BUILDING OFFICIAL:
DATE: _ _/-/y-
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
177/2019 1:27 PM EnergyGaugeO USA Section R405A.1 Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
- - - - - _PROJECT
-
-
Titre: TUBITO- PAYNE GUEST HO Bedrooms: 1
Address Type:
Street Address
Building Type: User Conditioned Area: 750
Lot #
Owner Name: T149;iTO Total Stories: 1
Block/Subdivision:
#of Units: 1 Worst Case: No
PlatBook:
Builder Name: -T&SC 6LOrLS Rotate Angle: 0
Street: 5%l03
OLEANDER AVENUE
Permit Office: ST LUCIE COUNTY Cross Ventilation: No
County.
St. Lucie
Jurisdiction: ST LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type: Single-family
FL,
New/Ewsdng: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 750 7851
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 KITCHEN 140 1400 Yes 0
1 Yes
Yes
Yes
2 LIVING ROOM 270 3051 No 0
1 Yes
Yes
Yes
3 BATH 80 800 No 0
1 Yes
Yes
Yes
4 WICMUNDRY 80 800 No 0
1 Yes
Yes
Yes
5 MASTER BEDROO 180 1800 No 0
1
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation KITCHEN 24 ft 0
140 ft'
1 0
0
2SIab-On-Grade Edge Insulation LIVING ROOM 33 ft 0
270 ft-
___
1 0
0
3SIab-On-Grade Edge Insulation BATH 8 ft 0
80 ft'
1 0
0
4 Slab -On -Grade Edge Insulation WIC/LAUNDRY 18ft 0
80 f1'
1 0
0
5SIab-On-Grade Edge Insulation MASTER BEDRO 27 ft 0
180 ft'
1 0
0
ROOF
/ Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1 Hip Composition shingles 839 ft- 0 ft' Medium
0.6
No 0.9
No 20
26.6
ATTIC
/
V # Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic Unvented 0
750 ft'
N N
1/7/2019 1:27 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
- --CEILING
-
-
-
#
Ceiling Type Space R-Value
Ins Type
Area
Framing Free Truss Type
_
1
Under Attic(Unvented) KITCHEN 20
Blown
140 ft'
0.1
Wood
_
2
Under Attic(Unvented) LIVING ROOM 20
Blown
270 ft'
0.1
Wood
_
3
Under Attic(Unvented) BATH 20
Blown
Soft'
0.1
Wood
_
4
Under Attic(Unvented) WIC/LAUNDRY 20
Blown
80 ft'
0.1
Wood
5
Under Attic (Unvented) MASTER BEDRO 20
Blown
180 ft'
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar
Below
_ 1
N
Exterior Concrete Block- Ext Insul KITCHEN 4.1 14
0 10
0
140.0 ft'
0
0 0.6
0
2
W
Exterior Concrete Block -EM Insul KITCHEN 4.1 10
0 10
0
100.0 ft'
0
0 0.6
0
_ 3
S
Exterior Concrete Block - Ext InsdIIVING ROO 4.1 18
0 11
4
204.0 ft'
0
0 0.6
0
-4
W
Exterior Concrete Block - Ext InsdIIVING ROO 4.1 15
0 11
4
170.0 ft'
0
0 0.6
0
_ 5
N
Exterior Concrete Block - Ext Insul BATH 4.1 8
0 10
0
80.0 ft'
0
0 0.6
0
6
N
Exterior Concrete Block- Ext Inst1NIC/LAUND 4.1 8
0 10
0
80.0 ft'
0
0 0.6
0
_ 7
E
Exterior Concrete Block- Ext InsdNICMUND 4.1 10
0 10
0
100.0 ft'
0
0 0.6
0
_ 8
E
Exterior Concrete Block- Ext InstWASTER BE 4.1 15
0 10
0
150.0 f6
0
0 0.6
0
9
S
Exterior Concrete Block - Ext InsWASTER BE 4.1 12
0 10
0
120.0 W
0
0 0.6
0
WINDOWS
Orientation shown Is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
W 2 Metal Low-E Single Yes 0.65 0.25
N
12.0 ft'
1 ft 6 in
1 ft 4 in
None
None
_
2
S 3 Metal Low-E Single Yes 0.65 0.25
N
24.0 ft'
1 ft 6 in
1 ft 4 in
None
None
_
3
W 4 Metal Low-E Single Yes 0.65 0.25
N
36.0 ft'
1 ft 6 in
1 ft 4 in
None
None
_
4
N 5 Metal Low-E Single Yes 0.65 0.25
N
4.0 ft'
1 ft 6 in
1 ft 4 in
None
None
_
5
E 8 Metal Low-E Single Yes 0.65 0.25
N
16.0 ft'
1 ft 6 in
1 ft 4 in
None
None
6
S 9 Metal Low-E Single Yes 0.65 0.25
N
24.0 W
1 ft 6 in
1 ft 4 in
None
None
INFILTRATION
#
Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000466 916 50.28
94.57
.3657
7
HEATING SYSTEM
#
System Type Subtype Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None COP:1
17 kBtu/hr
1
sys#1
1f7/2019 1:27 PM EnergyGaugeO USA Section R405.4.1 Compliant Software
Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
-COOLING_SYSTEM- -
# System Type
Subtype
Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
SEER: 16
18.8 kBtu/hr
564 cfm 0.8
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt Conservation
1 Electric
None
W IC/L AUNDR10.98
50 gal
60.9 gal
120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/ —Supply—
—Return—
Air
CFM 25 CFM25
HVAC#
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT OUT ON
RLF
Heat Cool
1 Attic
6 125 ft2
Attic
13 ft2
Default Leakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
Programabler[Thermostat:
Ceiling Fans:
an [ ]]N
Heating Jan [XJ Feb
r[�xJ,]
Mar
Apr
I May
DC�
Jun [ ]Jul
D(�
[ ]Aug
X� ] rDC'�
4 ]Sep L 1
Dec
([X�]
Venting I 1 Jan II 11 Feb
l l
[RI Mar
lxl
Apr
[ May
Jun [ 1 Jul
[ 1 Aug
[ 1 Sep lxl Oct [
Nov
[ ]DDec
ec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8 9 10
11
12
Cooling (WD) AM
78
78 78
78
78 78
78
78 80 80
80
80
PM
80
80 80
80
78 78
78
78 78 78
78
78
Cooling(WEH) AM
78
78 78
78
78 78
78
78 80 80
80
80
PM
80
80 80
80
78 78
78
78 78 78
78
78
Heating(WD) AM
65
65 65
65
65 65
65
68 68 68
68
68
PM
68
68 68
68
68 68
68
68 68 68
68
68
Heating (WEH) AM
65
65 65
65
65 65
65
68 68 68
68
68
PM
68
68 68
68
68 68
68
68 68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Defaull(81bs/sq.ft.
0 ft2
Oft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
LIVING ROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC/LAUNDRY
Default(8 lbs/s.fL
ft2
ft
0.3
MASTER BEDROO
Name:
Rating Compant:
IR12019 1:27 PM EnergyGaugeO USA Section R405A.1 Compliant Software Page 4 of 4
2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: TUBITO- PAYNE GUEST HOUSE Builder Name: 7-a& C-eLDR5 �C
Street: 5403 OLEANDERAVENUE Permit Office: STLUCIECOUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
U
Owner: TIAFi\To Jurisdiction: ST LUCIE COUNTY
=
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERI
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop dawn stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity Insulation shell be installed to
(including
maintain permanent contact with the underside of
above -garage
subfioor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures Installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exteriorwalls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
177/2019 1:28 PM EnergyGauge@ USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 87
The lower the Energy Performance Index, the more efficient the home
1. New home or, addition
1.
New (From Plans)
12. Ducts, location R, insulation level
a) Supply ducts
R 6.0
2. Single-family or multiple -family
2.
Single-family
b) Return ducts
R 6.0
c) AHU location
Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
1
13. Cooling system:
Capacity 18.8
a) Split system
SEER 16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package
SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
750
d) Room unit/PTAC
EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.650
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250
c) Area 7c. 116.0
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
14. Heating system: Capacity17.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
9b.
15. Water heating system
9c.
a) Electric resistance EF 0.98
b) Gas Fred, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
t0A1.
e) Dedicated heat pump with tank EF_
10A2. 4.1
f) Heat recovery unit HeatRec%
g) Other
10131.
10B2.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11 a. 20.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat No
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. Builder Signature: _/�'h'uDate: �'"xf-
/D
Address of New Home: OLEANDER AVENUE City/FL Zip: FORT PIERCE. FL
1/7/2019 1:28:08 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
+ wrightsoft
Project Summary
Entire -
House ---QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-4666799 Fax 772466-6796 Email' OUICKCALCS@AOL.COM
For. TUBITO/PAYNEGUEST HOUSE
OLEANDER AVENUE, FORT PIERCE, FL
Notes:
Design Information
Weather. Fort Pierce, FL, US
Winter Design Conditions
Outside db
Inside db
Design TD
Job:
Date: Jan 07, 2019
ey: _
Summer Design Conditions
42 OF Outside db
70 OF Inside db
28 OF Design TD
Daily range
Relative humidity
Moisture difference
Heating Summary
Structure 13534 Btuh
Ducts 2057 Btuh
Central vent (0 cfm) 0 Btuh
(none)
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 15591 Btuh
Infiltration
Method Simplified
Construction quality Average
Fireplaces 0
Heat7Coo g
l
Area fta
5g
Volume (ft3)
7851
7851
Airchanges/hour
0.61
0.32
Equiv. AVF (cfm)
80
42
Heating Equipment
Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
100 EFF
4.3 kW
14820 Btuh
22 OF
627 cfm
0.040 cfm/Btuh
1.00 in H2O
90 OF
75 OF
15 M OF
50 %
61 gr/lb
Sensible Cooling Equipment Load Sizing
Structure
10544
Btuh
Ducts
3078
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Equipmenf sensible load
12941
Btuh
Latent Cooling Equipment Load Sizing
Structure
2949
Btuh
Ducts
811
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
3760
Btuh
Equipment Total Load (Sen+Lat)
16701
Btuh
Req. total capacity at 0.70 SHR
1.5
ton
Cooling Equipment Summary
Make Trane
Trade TRANE
Cond 4TTR4018L1
Coil TEM6AOB24H21++TDR
AHRI ref 7567539
Efficiency 13.0 EER, 16
SEER
Sensible cooling
13160
Btuh
Latent cooling
5640
Btuh
Total cooling
18800
Btuh
Actual air flow
627
cfm
Air flow factor
0.046
cfm/Btuh
Static pressure
1.00
in H2O
Load sensible heat ratio
0.78
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrighisoR- 20194an-0713:27:13
•'•"" —+ Right-SulteD Universal 2018 18.0.31 RSU06101 Page 1
ACCK ...\wnghtsoft WAC\TUBITO PAYNE GUEST HOUSE.mp Cato = MJ8 Front Door faces: S
wrightsoft' Right-M) Worksheet Job:
Cnfirn Fln��cn Date: Jan 07, 2019
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS a1AOL.COM
1
2
3
4
5
Room name
E.,qosed wall
Room height
Room dimensions
Room area
Entire House
110.0 it
10.5 ft
750.0 ft2
WCHEN
24.0 It
10.0 ft heat/cod
14.0 x 10.0 ft
140.0 ft2
Ty
Construction
number
U-value
(B1uIvft2-°F)
Or
HTM
(Btuhlft=
Area (it)
or perimeter (ft)
Load
(Btuh)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
NIP/S
Heat
Cool
Gross
I N/P/S
Heat
Cool
6
11
IN
13943cs
2:glazing, clr lows_
13A-4=
2 olaznw, clr lows
13A-0ocs ^
2glazing,.Gclow —
13A-4ocs
2 glazing, cir lcw a
2plazing, plr lqw�_
16A-30ad
22A-tph
0.143
_0.650
0.143
0.650
—0.143
_._.0.650
0.143
0.650
0.650
_0.032
1.358
n
_n_
a
_e_
s
_a-
w
w
w
<
-
d 00
_1820
4.00
18.20
4.00
—78.20
4.00
18.20
18.20
<0.90
38.02
42.19
__ 14.99
2.19
�33.77
2.19
_14.99
2.19
33.77
33.77
--2.24
0,00
— 300
_� 4
250
_ 16
323
—.48
270
12
36
__ Z50
750
— 2B6
„_0
234
0
1185
___73
937
291
1103
...-874
887
218
655
672
41830
6A8
,«60
512
540
�603
__720
485
405
1216
_._-.,,.1680
140
0
'u 140
""56'I
— 306
.
W,
�_r'
VV��/1
`G
0
0
_0
0
0
_0
0
0
—0
0
_0
--0
0
193
405
0
-.,�314
--0
_
� 275
e.48
222
0
0
v_750
110
0-0-0
—0
100
12
0
�140140125
140
—...._0
88
0
0
24
__-0
352
218
0
913
_
C^
F
6
c)AED excursion
286
118
Envelope loss/gam
11078
7154
2169
1336
12
a) infiltration
b) Room ventilation
2456
0
690
0
516
0
145
0
13
Internal gains: Occupants @ 230
Appliances/other
0
0
27001
0
1
0
1 300
Subtotal (lines 6to 13)
135M
10544
2685
1781
14
15
Less wderral load
Lesslmrsfer
Redistribution
Subtotal
Duct loads
150/0
29%
0
0
0
13534
2D57
0
0
0
10544
3078
15/
29%
0
0
0
2685
408
0
0
0
1781
520
Total room load
Airrequired (cfm)
15591
627
13622
627
3093
124
2301
106
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
w`.-9~..d'o._H- 2019-Jan-0713:27:13
I&K RightSuile® Unhersal 2018 18.0.31 RSUD8101 Page 1
...\Wrightsolt WAC\TUBITO PAYNE GUEST HOUSE.rup Calc=MJ8 Front Door faces: S
wrightsoft2
Right-JO Worksheet
—Entire-House-- - -
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724666799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM
Job:
Date: Jan 07, 2019
Bin
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensicns
Room area
LIVING ROOM
33.0 It
11.3 ft heat/cool
18.0 x 15.0 ft
270.0 ft2
RATH
8.0 ft
10.0 It heaticool
8.0 x 10.0 ft
80.0 ft2
Ty
Construction
number
U-wlue
(BtuNft2-°F)
Or
HTM
(13tuh/ft2)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
NIP/S
Heat
Cool
Gross
N/PIS
I Heat I
Cool
6
11
WVy
I`^-
13A4ocn -�--
2.glazirg, clr low-e_
13A-0ocs
2 olazino, or lcw:
13A4ocs
2 glazing, clr.low-e -
-- 0343
_0.650
0.143
0.650
—0.143
—0.650
n
_n_
a
_a-
s
,s-
— 4.00
._.18.20
4.00
18.20
4.00
—18.20
—219
_14.99
219
33.77
2.19
—14.99
0
---0
0
0
0
0
0
0
—80
—76
`304
73
0
_ 0
0
0
—166
60
0
_,__0
0
--0
IN
�--fa
VVyy
�G
_0
0
0
179
—24
_0
0
0
718
—437
0
_ 0
393
_360
—_4
0
0
��0
--0
_�0
0
0
203
—24
0
0
4y
13A-4ocs
2 glazing, clr loves
2 glazind, clrlowa
16ASOad
0.143
0.650
0.650
_0.032
w
w
_ w
4.00
18.20
18.20
�0.90
2.19
33.77
33.77
_224
170
0
36
____270
270
134
0
_0
270
33
535
0
v655
�242
1255
292
0
1216
—605
0
0
0
0
0
0
0
0
0
0
0
0
0
0
C�
F
_80
80
80
8
;72
304
22Atoh
1.358
38.02
0.00
6
c)AE1 excursion
325
-14
Envelope loss/gain
3842
3190
753
392
12
a) Infiltration
b) Room ventilation
801
0
225
0
172
0
48
0
13
Internal gains: Occupants @ 230
Appliances/other
0
0
4001
0
0
0
Subtotal (lines 6 to 13)
4643
3815
925
440
14
15
Less e#emal load
Less trensfer
Redistribution
Subtotal
Duct loads
15%
29%
0
0
0
4643
706
0
0
0
3815
1113
15%
29%
0
0
0
925
141
0
0
0
440
128
Total mom load
Alr required(ofm)
5349
215
4928
227
1066
43
568
26
Calculations approved bVACCA to meet all requirements of Manual J 8th Ed.
-r}H wrig_Fitvo6ft- 2019-Jan-0713:27:13
.4C�h RightSuite® Universal 201818.0.31 RSU08101 Page 2
...lwrightsoe WACITUBITO PAYNE GUEST HOUSE rup Calc = MJB Front Door faces: S
+ wrightsoft
Right-M Worksheet
--Entire-House__
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: GUICKCALCS@AOL.COM
Job:
Date: Jan 07, 2019
ey. -
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
WIC/LAUNDRY
18.0 ft
10.0 ft hea lcool
8.0 x 10.0 ft
80.0 ft-
MASTERBEDROOM
27.0 ft
10.0 ft heat(cool
120 x 15.0 ft
180.0 ft'
Ty
Construction
number
U-value
(Bluh/ftVF)
Or
HTM
stuh/ft')
Area (ft.)
or perimeter (ft)
Load
(Btuh)
Am (W)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
NIP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
11
W'
L-G
y/
-C
V I--G
y/
0.143
.__,0.650
0.143
0.650
0.143
-0.6W
0.143
0.650
0.650
__0.032
n
-_n_
a
e_
s
_s_
w
w
_w_
__
4.00
_18.20
4.00
_18.20
4.00
__11120
4.00
18.20
_18.20
_0.90
-2:19
_14.99
2.19
_33.77
219
-14.99
2.19
33.77
33.77
_2.24
---80
,_,__0
100
_ _ 0
--0
_0
0
0
_0
_60
60
___- 0
100
0
---0
-,0
0
0
0
=80
-^320
-175
_„_.__0
219
_ _0
^ 0
-._D
0
0
0
_179
0
13A-0ocs
2 glazing, clr,lowQ_. -
13A-0ocs
2 alazirq�cir lows _
13A-0pcs
2glazing,.ciclow-e-_
13AAccs
2 glazing, Gr low-e
2 glazing, air low-e
16A30ad _
22A-10
--0
_„-0
150
16
120
_-24
0
0
__0
= 180
180
0
_ __0
134
0
96
-_24
0
0
_0
, _�,180
27
0
-:0
537
291
�384
-437.
0
0
__0
, �161.
1027
0
--0
293
`540
210
--360
0
0
��-0
403
0
_0
400
0
0
-0
0
0
_0
� 72
II----_GG
C�
F
i1.358
=
0.00
80
18
fi84
e38.02
6
c)AED excursion
-36
-106
Envelope loss/gain
1477
537
2837
1700
12
a) Urfiltralion
b) Room ventilation
387
0
109
0
580
0
163
0
13
Internal gains: Occupants @ 230
Appliances/other
0
0
Soo
0
0
I 15M
Subtotal (lines 6to 13)
1864
1145
3417
3363
14
15
Less edemal load
Less transfer
Redistribution
Subtotal
Duct loads
159/6
29%
0
0
0
1864
283
0
0
0
1145
334
15%
29%
0
0
0
3417
519
0
0
0
3363
982
Total room load
Air required (cm)
2147
1 86
1480
68
3937
158
4345
200
Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed
rt}► wrYsr+�oM- Right-2019-Jan-07 13:27:13
.4&A AYNE UESDnOUSE.mipiversal ale=1J8 Front
Page
...\Wrightsofl HVAC\NBITO PAVNE GUEST HDUSE.Np Cale = MJ8 Fronl Door faces: S
sJob:
- � wr-Ightsoft°- - Duct Stem Summary — System _ � - Dace: Jan 07, 2019
Entire House By:
QUICK CALCS, INC.
317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 FaX 772466-6796 Ennall: QUICKCALCS@AOL.COM
For: TUBITO/PAYNEGUEST HOUSE
5103 OLEANDERAVENUE, FORT PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply/ return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
1.00
in H2O
0
in H2O
1.00
in H2O
0,500 / 0.500
in H2O
1.000
in/100ft
627
cfm
Cooling
1.00
in H2O
0
in H2O
1.00
in H2O
0.500 / 0.500
in H2O
1.000
in/100ft
627
cfm
137 ft
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mall
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 1066
43
26
1.000
5.0
Ox0
VIFx
4.2
115.0
st1
KITCHEN
h 3093
124
106
1.000
7.0
Ox0
VIFx
11.5
115.0
st1
LIVING ROOM
c 2464
108
113
1.000
7.0
Ox0
VIFx
22.1
115.0
st2
LIVING ROOM -A
c 2464
108
113
1.000
7.0
OxO
VIFx
11.4
115.0
st2
MASTER BEDROOM
c 2172
79
100
1.000
7.0
OXO
VIFx
11.0
115.0
st2
MASTER BEDROOM -A
C 2172
79
100
1.000
7.0
OXO
VIFx
14.5
115.0
st2
WIC/LAUNDRY
h 2147
86
68
1.000
6.0
Ox0
VIFx
5.1
115.0
st1
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st2
Peak AVF
373
427
1.000
647
11.0
0 x 0
VinlFlx
st1
Peak AVF
254
200
1.000
727
8.0
0 x 0
VinlFlx
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
627
627
F 0
0
0
0
NO
I
VIFx
wrightsoR^
RighlSuileO Universal 2018 18.0.31 RSU08101
...\Wnghtsoft HVAC%TUBITO PAYNE GUEST HOUSE.nip Cale = MJ8 Front Door faces: 3
2019Jan-07 13:27:13
Page 1
Front Elevation
Riph[Elevation
Safe Load Table Nana
]nsmllation Nate
�. �MaxyvYVwM.Yr
a.YnYIY
o..a>ur3.ourdw—e+
.u�—.rr..w
—{
fy
JJ..
_aa
Camposim U GnW Nbu ivls
.. 8FI61B/IT
Lintel Tvoe Desimatlon
•r..r.u�wmvrn.•v
Cart in nlam sill or Tie Beam
Option
In she ewa met psaui padurn eR dmoggd W ma
Oeldeeh lnP�'s�Wys®rile heumnmy 6easN rot
z wi'W-jt) evd� NS
mk 8�` 12 b! by
ba�ro�'
Isft 6hl•
eL
pa ttLduW=
a
Bvildim Data
Desim Loads Sw ofWoh
o.r<srsv.ara
�rM V
uwu.n.r mov.r w.mamon
MWIst YOpJ. Shµro�mib.
No`e rlSal-M1�
w4+.� IDri1
vym.m. vw.r
sv.m. io
Buildia¢Code
p,
p Gr
Area Tabdatim
w..e>dr .0 Svnvrwa.smao.Ys.u®u
o
weeeo� SouNw.avraoe.nn.n
i
p
Fnuy: IBO
ns�.e<6c.wmawid.n.
0a m
T.W: 930
•�..s�� ��
G LLi�
as p
rwn<s,....eueHg smos.oMaaeuY.
�= <
Ta LLhie
V a �5
orr.�wnr Y.a
o
ale
Cyst Crt Linrcl SchWde
? e 6
�oYmue.v5mamw.
n
MW LYaerygfeyytr���¢¢4hmsMbimuW Ntlaa�mmeN
tt3 �udrB5roai5crtngve�INa
�mw<S