Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FILE COPY --- - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: TUBITO- PAYNE GUEST HOUSE Builder Name: IF-LESE oWOUS al Street: 57o3 OLEANDERAVENUE Permit Office: STLUCIECOUNTY n1 SCANNED City, State, Zip: FORT PIERCE, FL, Permit Number. Owner.-ruenjj Jurisdiction: ST LUCIE COUNTY BY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 B't Lucie COurlty 1. New construction or existing New (From Plans) 9. Wall Types (1144.0 sgfL) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1144.00 ft2 b. N/A R= fN 3. Number of units, it multiple family 1 c. N/A R= fl2 4. Number of Bedrooms 1 d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types (750.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=20.0 750.00 ft2 6. Conditioned Floor area above grade (ft2) 750 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= 112 11. Ducts R f6 7. Windows (116.0 sgft.) Description Area a. Sup: Attic, Rat Attic, AH: Attic 6 125 a. U-Factor: SgI, U=0.65 116.00 ft2 SHGC: SHGC=0.25 b. U-Factor: NIA ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.8 SEER:16.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtLdhr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (750.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 750.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.155 Total Proposed Modified Loads: 31.54 PASS Total Baseline Loads: 36.41 I hereby certify that the plans and specifications covered by Review of the plans and FSHE S79T this calculation are in compliance with the Florida Energy specifications covered by this O Code. calculation indicates compliance gar;°6 with the Florida Energy Code. F rrn�rs..'•o •:i e?',i.••`=�o O� PREPA D Before construction is completed Ty. DATE: this building will be inspected for compliance with Section553.908 ..• '.c. I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy C �a. Wy t1~� OWNER/AGENT- / BUILDING OFFICIAL: DATE: _ _/-/y- DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 177/2019 1:27 PM EnergyGaugeO USA Section R405A.1 Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT - - - - - _PROJECT - - Titre: TUBITO- PAYNE GUEST HO Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 750 Lot # Owner Name: T149;iTO Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: -T&SC 6LOrLS Rotate Angle: 0 Street: 5%l03 OLEANDER AVENUE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Ewsdng: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 750 7851 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 KITCHEN 140 1400 Yes 0 1 Yes Yes Yes 2 LIVING ROOM 270 3051 No 0 1 Yes Yes Yes 3 BATH 80 800 No 0 1 Yes Yes Yes 4 WICMUNDRY 80 800 No 0 1 Yes Yes Yes 5 MASTER BEDROO 180 1800 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation KITCHEN 24 ft 0 140 ft' 1 0 0 2SIab-On-Grade Edge Insulation LIVING ROOM 33 ft 0 270 ft- ___ 1 0 0 3SIab-On-Grade Edge Insulation BATH 8 ft 0 80 ft' 1 0 0 4 Slab -On -Grade Edge Insulation WIC/LAUNDRY 18ft 0 80 f1' 1 0 0 5SIab-On-Grade Edge Insulation MASTER BEDRO 27 ft 0 180 ft' 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 839 ft- 0 ft' Medium 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 750 ft' N N 1/7/2019 1:27 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT - --CEILING - - - # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type _ 1 Under Attic(Unvented) KITCHEN 20 Blown 140 ft' 0.1 Wood _ 2 Under Attic(Unvented) LIVING ROOM 20 Blown 270 ft' 0.1 Wood _ 3 Under Attic(Unvented) BATH 20 Blown Soft' 0.1 Wood _ 4 Under Attic(Unvented) WIC/LAUNDRY 20 Blown 80 ft' 0.1 Wood 5 Under Attic (Unvented) MASTER BEDRO 20 Blown 180 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block- Ext Insul KITCHEN 4.1 14 0 10 0 140.0 ft' 0 0 0.6 0 2 W Exterior Concrete Block -EM Insul KITCHEN 4.1 10 0 10 0 100.0 ft' 0 0 0.6 0 _ 3 S Exterior Concrete Block - Ext InsdIIVING ROO 4.1 18 0 11 4 204.0 ft' 0 0 0.6 0 -4 W Exterior Concrete Block - Ext InsdIIVING ROO 4.1 15 0 11 4 170.0 ft' 0 0 0.6 0 _ 5 N Exterior Concrete Block - Ext Insul BATH 4.1 8 0 10 0 80.0 ft' 0 0 0.6 0 6 N Exterior Concrete Block- Ext Inst1NIC/LAUND 4.1 8 0 10 0 80.0 ft' 0 0 0.6 0 _ 7 E Exterior Concrete Block- Ext InsdNICMUND 4.1 10 0 10 0 100.0 ft' 0 0 0.6 0 _ 8 E Exterior Concrete Block- Ext InstWASTER BE 4.1 15 0 10 0 150.0 f6 0 0 0.6 0 9 S Exterior Concrete Block - Ext InsWASTER BE 4.1 12 0 10 0 120.0 W 0 0 0.6 0 WINDOWS Orientation shown Is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 2 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft' 1 ft 6 in 1 ft 4 in None None _ 2 S 3 Metal Low-E Single Yes 0.65 0.25 N 24.0 ft' 1 ft 6 in 1 ft 4 in None None _ 3 W 4 Metal Low-E Single Yes 0.65 0.25 N 36.0 ft' 1 ft 6 in 1 ft 4 in None None _ 4 N 5 Metal Low-E Single Yes 0.65 0.25 N 4.0 ft' 1 ft 6 in 1 ft 4 in None None _ 5 E 8 Metal Low-E Single Yes 0.65 0.25 N 16.0 ft' 1 ft 6 in 1 ft 4 in None None 6 S 9 Metal Low-E Single Yes 0.65 0.25 N 24.0 W 1 ft 6 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000466 916 50.28 94.57 .3657 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 1f7/2019 1:27 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT -COOLING_SYSTEM- - # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 18.8 kBtu/hr 564 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None W IC/L AUNDR10.98 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 125 ft2 Attic 13 ft2 Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programabler[Thermostat: Ceiling Fans: an [ ]]N Heating Jan [XJ Feb r[�xJ,] Mar Apr I May DC� Jun [ ]Jul D(� [ ]Aug X� ] rDC'� 4 ]Sep L 1 Dec ([X�] Venting I 1 Jan II 11 Feb l l [RI Mar lxl Apr [ May Jun [ 1 Jul [ 1 Aug [ 1 Sep lxl Oct [ Nov [ ]DDec ec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Defaull(81bs/sq.ft. 0 ft2 Oft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 LIVING ROOM Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 WIC/LAUNDRY Default(8 lbs/s.fL ft2 ft 0.3 MASTER BEDROO Name: Rating Compant: IR12019 1:27 PM EnergyGaugeO USA Section R405A.1 Compliant Software Page 4 of 4 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: TUBITO- PAYNE GUEST HOUSE Builder Name: 7-a& C-eLDR5 �C Street: 5403 OLEANDERAVENUE Permit Office: STLUCIECOUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: U Owner: TIAFi\To Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop dawn stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity Insulation shell be installed to (including maintain permanent contact with the underside of above -garage subfioor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures Installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 177/2019 1:28 PM EnergyGauge@ USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 87 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location R, insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 1 13. Cooling system: Capacity 18.8 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 750 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 116.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 14. Heating system: Capacity17.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 9b. 15. Water heating system 9c. a) Electric resistance EF 0.98 b) Gas Fred, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF t0A1. e) Dedicated heat pump with tank EF_ 10A2. 4.1 f) Heat recovery unit HeatRec% g) Other 10131. 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11 a. 20.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: _/�'h'uDate: �'"xf- /D Address of New Home: OLEANDER AVENUE City/FL Zip: FORT PIERCE. FL 1/7/2019 1:28:08 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 + wrightsoft Project Summary Entire - House ---QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-4666799 Fax 772466-6796 Email' OUICKCALCS@AOL.COM For. TUBITO/PAYNEGUEST HOUSE OLEANDER AVENUE, FORT PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Job: Date: Jan 07, 2019 ey: _ Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 13534 Btuh Ducts 2057 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 15591 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heat7Coo g l Area fta 5g Volume (ft3) 7851 7851 Airchanges/hour 0.61 0.32 Equiv. AVF (cfm) 80 42 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 4.3 kW 14820 Btuh 22 OF 627 cfm 0.040 cfm/Btuh 1.00 in H2O 90 OF 75 OF 15 M OF 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 10544 Btuh Ducts 3078 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipmenf sensible load 12941 Btuh Latent Cooling Equipment Load Sizing Structure 2949 Btuh Ducts 811 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 3760 Btuh Equipment Total Load (Sen+Lat) 16701 Btuh Req. total capacity at 0.70 SHR 1.5 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TTR4018L1 Coil TEM6AOB24H21++TDR AHRI ref 7567539 Efficiency 13.0 EER, 16 SEER Sensible cooling 13160 Btuh Latent cooling 5640 Btuh Total cooling 18800 Btuh Actual air flow 627 cfm Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.78 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrighisoR- 20194an-0713:27:13 •'•"" —+ Right-SulteD Universal 2018 18.0.31 RSU06101 Page 1 ACCK ...\wnghtsoft WAC\TUBITO PAYNE GUEST HOUSE.mp Cato = MJ8 Front Door faces: S wrightsoft' Right-M) Worksheet Job: Cnfirn Fln��cn Date: Jan 07, 2019 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS a1AOL.COM 1 2 3 4 5 Room name E.,qosed wall Room height Room dimensions Room area Entire House 110.0 it 10.5 ft 750.0 ft2 WCHEN 24.0 It 10.0 ft heat/cod 14.0 x 10.0 ft 140.0 ft2 Ty Construction number U-value (B1uIvft2-°F) Or HTM (Btuhlft= Area (it) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross I N/P/S Heat Cool 6 11 IN 13943cs 2:glazing, clr lows_ 13A-4= 2 olaznw, clr lows 13A-0ocs ^ 2glazing,.Gclow — 13A-4ocs 2 glazing, cir lcw a 2plazing, plr lqw�_ 16A-30ad 22A-tph 0.143 _0.650 0.143 0.650 —0.143 _._.0.650 0.143 0.650 0.650 _0.032 1.358 n _n_ a _e_ s _a- w w w < - d 00 _1820 4.00 18.20 4.00 —78.20 4.00 18.20 18.20 <0.90 38.02 42.19 __ 14.99 2.19 �33.77 2.19 _14.99 2.19 33.77 33.77 --2.24 0,00 — 300 _� 4 250 _ 16 323 —.48 270 12 36 __ Z50 750 — 2B6 „_0 234 0 1185 ___73 937 291 1103 ...-874 887 218 655 672 41830 6A8 ,«60 512 540 �603 __720 485 405 1216 _._-.,,.1680 140 0 'u 140 ""56'I — 306 . W, �_r' VV��/1 `G 0 0 _0 0 0 _0 0 0 —0 0 _0 --0 0 193 405 0 -.,�314 --0 _ � 275 e.48 222 0 0 v_750 110 0-0-0 —0 100 12 0 �140140125 140 —...._0 88 0 0 24 __-0 352 218 0 913 _ C^ F 6 c)AED excursion 286 118 Envelope loss/gam 11078 7154 2169 1336 12 a) infiltration b) Room ventilation 2456 0 690 0 516 0 145 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 27001 0 1 0 1 300 Subtotal (lines 6to 13) 135M 10544 2685 1781 14 15 Less wderral load Lesslmrsfer Redistribution Subtotal Duct loads 150/0 29% 0 0 0 13534 2D57 0 0 0 10544 3078 15/ 29% 0 0 0 2685 408 0 0 0 1781 520 Total room load Airrequired (cfm) 15591 627 13622 627 3093 124 2301 106 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. w`.-9~..d'o._H- 2019-Jan-0713:27:13 I&K RightSuile® Unhersal 2018 18.0.31 RSUD8101 Page 1 ...\Wrightsolt WAC\TUBITO PAYNE GUEST HOUSE.rup Calc=MJ8 Front Door faces: S wrightsoft2 Right-JO Worksheet —Entire-House-- - - QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724666799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM Job: Date: Jan 07, 2019 Bin 1 2 3 4 5 Room name Exposed wall Room height Room dimensicns Room area LIVING ROOM 33.0 It 11.3 ft heat/cool 18.0 x 15.0 ft 270.0 ft2 RATH 8.0 ft 10.0 It heaticool 8.0 x 10.0 ft 80.0 ft2 Ty Construction number U-wlue (BtuNft2-°F) Or HTM (13tuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/PIS I Heat I Cool 6 11 WVy I`^- 13A4ocn -�-- 2.glazirg, clr low-e_ 13A-0ocs 2 olazino, or lcw: 13A4ocs 2 glazing, clr.low-e - -- 0343 _0.650 0.143 0.650 —0.143 —0.650 n _n_ a _a- s ,s- — 4.00 ._.18.20 4.00 18.20 4.00 —18.20 —219 _14.99 219 33.77 2.19 —14.99 0 ---0 0 0 0 0 0 0 —80 —76 `304 73 0 _ 0 0 0 —166 60 0 _,__0 0 --0 IN �--fa VVyy �G _0 0 0 179 —24 _0 0 0 718 —437 0 _ 0 393 _360 —_4 0 0 ��0 --0 _�0 0 0 203 —24 0 0 4y 13A-4ocs 2 glazing, clr loves 2 glazind, clrlowa 16ASOad 0.143 0.650 0.650 _0.032 w w _ w 4.00 18.20 18.20 �0.90 2.19 33.77 33.77 _224 170 0 36 ____270 270 134 0 _0 270 33 535 0 v655 �242 1255 292 0 1216 —605 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C� F _80 80 80 8 ;72 304 22Atoh 1.358 38.02 0.00 6 c)AE1 excursion 325 -14 Envelope loss/gain 3842 3190 753 392 12 a) Infiltration b) Room ventilation 801 0 225 0 172 0 48 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 4001 0 0 0 Subtotal (lines 6 to 13) 4643 3815 925 440 14 15 Less e#emal load Less trensfer Redistribution Subtotal Duct loads 15% 29% 0 0 0 4643 706 0 0 0 3815 1113 15% 29% 0 0 0 925 141 0 0 0 440 128 Total mom load Alr required(ofm) 5349 215 4928 227 1066 43 568 26 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. -r}H wrig_Fitvo6ft- 2019-Jan-0713:27:13 .4C�h RightSuite® Universal 201818.0.31 RSU08101 Page 2 ...lwrightsoe WACITUBITO PAYNE GUEST HOUSE rup Calc = MJB Front Door faces: S + wrightsoft Right-M Worksheet --Entire-House__ QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: GUICKCALCS@AOL.COM Job: Date: Jan 07, 2019 ey. - 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area WIC/LAUNDRY 18.0 ft 10.0 ft hea lcool 8.0 x 10.0 ft 80.0 ft- MASTERBEDROOM 27.0 ft 10.0 ft heat(cool 120 x 15.0 ft 180.0 ft' Ty Construction number U-value (Bluh/ftVF) Or HTM stuh/ft') Area (ft.) or perimeter (ft) Load (Btuh) Am (W) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross WP/S Heat Cool 6 11 W' L-G y/ -C V I--G y/ 0.143 .__,0.650 0.143 0.650 0.143 -0.6W 0.143 0.650 0.650 __0.032 n -_n_ a e_ s _s_ w w _w_ __ 4.00 _18.20 4.00 _18.20 4.00 __11120 4.00 18.20 _18.20 _0.90 -2:19 _14.99 2.19 _33.77 219 -14.99 2.19 33.77 33.77 _2.24 ---80 ,_,__0 100 _ _ 0 --0 _0 0 0 _0 _60 60 ___- 0 100 0 ---0 -,0 0 0 0 =80 -^320 -175 _„_.__0 219 _ _0 ^ 0 -._D 0 0 0 _179 0 13A-0ocs 2 glazing, clr,lowQ_. - 13A-0ocs 2 alazirq�cir lows _ 13A-0pcs 2glazing,.ciclow-e-_ 13AAccs 2 glazing, Gr low-e 2 glazing, air low-e 16A30ad _ 22A-10 --0 _„-0 150 16 120 _-24 0 0 __0 = 180 180 0 _ __0 134 0 96 -_24 0 0 _0 , _�,180 27 0 -:0 537 291 �384 -437. 0 0 __0 , �161. 1027 0 --0 293 `540 210 --360 0 0 ��-0 403 0 _0 400 0 0 -0 0 0 _0 � 72 II----_GG C� F i1.358 = 0.00 80 18 fi84 e38.02 6 c)AED excursion -36 -106 Envelope loss/gain 1477 537 2837 1700 12 a) Urfiltralion b) Room ventilation 387 0 109 0 580 0 163 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 Soo 0 0 I 15M Subtotal (lines 6to 13) 1864 1145 3417 3363 14 15 Less edemal load Less transfer Redistribution Subtotal Duct loads 159/6 29% 0 0 0 1864 283 0 0 0 1145 334 15% 29% 0 0 0 3417 519 0 0 0 3363 982 Total room load Air required (cm) 2147 1 86 1480 68 3937 158 4345 200 Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed rt}► wrYsr+�oM- Right-2019-Jan-07 13:27:13 .4&A AYNE UESDnOUSE.mipiversal ale=1J8 Front Page ...\Wrightsofl HVAC\NBITO PAVNE GUEST HDUSE.Np Cale = MJ8 Fronl Door faces: S sJob: - � wr-Ightsoft°- - Duct Stem Summary — System _ � - Dace: Jan 07, 2019 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 FaX 772466-6796 Ennall: QUICKCALCS@AOL.COM For: TUBITO/PAYNEGUEST HOUSE 5103 OLEANDERAVENUE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0,500 / 0.500 in H2O 1.000 in/100ft 627 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm 137 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 1066 43 26 1.000 5.0 Ox0 VIFx 4.2 115.0 st1 KITCHEN h 3093 124 106 1.000 7.0 Ox0 VIFx 11.5 115.0 st1 LIVING ROOM c 2464 108 113 1.000 7.0 Ox0 VIFx 22.1 115.0 st2 LIVING ROOM -A c 2464 108 113 1.000 7.0 OxO VIFx 11.4 115.0 st2 MASTER BEDROOM c 2172 79 100 1.000 7.0 OXO VIFx 11.0 115.0 st2 MASTER BEDROOM -A C 2172 79 100 1.000 7.0 OXO VIFx 14.5 115.0 st2 WIC/LAUNDRY h 2147 86 68 1.000 6.0 Ox0 VIFx 5.1 115.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 373 427 1.000 647 11.0 0 x 0 VinlFlx st1 Peak AVF 254 200 1.000 727 8.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 627 627 F 0 0 0 0 NO I VIFx wrightsoR^ RighlSuileO Universal 2018 18.0.31 RSU08101 ...\Wnghtsoft HVAC%TUBITO PAYNE GUEST HOUSE.nip Cale = MJ8 Front Door faces: 3 2019Jan-07 13:27:13 Page 1 Front Elevation Riph[Elevation Safe Load Table Nana ]nsmllation Nate �. �MaxyvYVwM.Yr a.YnYIY o..a>ur3.ourdw—e+ .u�—.rr..w —{ fy JJ.. _aa Camposim U GnW Nbu ivls .. 8FI61B/IT Lintel Tvoe Desimatlon •r..r.u�wmvrn.•v Cart in nlam sill or Tie Beam Option In she ewa met psaui padurn eR dmoggd W ma Oeldeeh lnP�'s�Wys®rile heumnmy 6easN rot z wi'W-jt) evd� NS mk 8�` 12 b! by ba�ro�' Isft 6hl• eL pa ttLduW= a Bvildim Data Desim Loads Sw ofWoh o.r<srsv.ara �rM V uwu.n.r mov.r w.mamon MWIst YOpJ. Shµro�mib. No`e rlSal-M1� w4+.� IDri1 vym.m. vw.r sv.m. io Buildia¢Code p, p Gr Area Tabdatim w..e>dr .0 Svnvrwa.smao.Ys.u®u o weeeo� SouNw.avraoe.nn.n i p Fnuy: IBO ns�.e<6c.wmawid.n. 0a m T.W: 930 •�..s�� �� G LLi� as p rwn<s,....eueHg smos.oMaaeuY. �= < Ta LLhie V a �5 orr.�wnr Y.a o ale Cyst Crt Linrcl SchWde ? e 6 �oYmue.v5mamw. n MW LYaerygfeyytr���¢¢4hmsMbimuW Ntlaa�mmeN tt3 �udrB5roai5crtngve�INa �mw<S