Loading...
HomeMy WebLinkAboutEVALUATION REPORTSCq NEMO I etc. Certificate o/Authorizatlon #31455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST WryO'ONSULT CERTIFY EVALUATION REPORT Polyglass USA, Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 (954)233-1230 Evaluation Report P12060.02.09-R24 FL5259-R28 Date of Issuance:02/24/2009 Revision 24: 01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Cade and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO)etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: Robert I.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 01/24/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOIetc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMOI etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMOletc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6t6 Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3 / 1507.1.1 Physical Properties ASTM D226 2009 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRI01111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MTI (TST 2508) Physical Properties 1X20117A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30S40.11.09-R1 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD (TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD (TST 6049) Physical Properties P11O30.11.09-3 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD (TST 6049) Physical Properties P37300.10.11 10/19/2011 NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R24 Certifiwte oJAuthotizvtion#32455 6' EDMON (2017) FBC NON-HVHZ EVALUATION FL5259-RZ8 Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018 Page 2 of 14 ONEMOjetc. Enti Examination Reference Date ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD (TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 ERD (TST 6049) Wind Uplift P11781.11.03-R3 11/26/2013 ERD (TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD (rST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD (TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD (TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD (TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD (TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD (TST 6049) Physical Properties P44360.10.14-R1 05/18/2015 ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 OS/20/2015 ERD (TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 ERD (TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD (TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016 ERD (TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 ERD (TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017 ICC-ES(EVL 2396) IBCCompliance ESR-1697 11/01/2014 Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA P/LAffidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL, U.C. (QUA9625) Quality Control Service Confirmation Exp.10/05/2018 4. PRODUCT DESCRIPTION: 4.1 Mechanically Fastened Underlaymerits 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. 4.2 _ self -Adhering Underlayments: 4.2.1 Polystick MTS or Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets FRSA/TRI April 2012. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, U.C. Evaluation Report P32060.02.09-R24 Certificate of Authorization #32455 a EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 3 of 14 ONEMO etc. 4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets FRSA/TRI April 2012. 4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012. 4.2.7 Polystick Dual ProTM is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyesterfabricsurface; meets ASTM D1970. 4.2.8 Polystick Tile ProT" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyesterfabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 5.8). 4.3 Mechanically Fastened and/or Bonded Underlayments: 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. 4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164. Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex 56 G FR is for use as an alternate to Hot Asphalt applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet' in the 'Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMOIetc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is notfor use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R24 Certificate o7AuthariMwn N32455 a EDITION(2017) FBC NON-HVHZ EVALUATION FL5259-RZ8 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 4 of 14 0NEM0je_tc.______ 5.5 Allowable Roof Covers: TABLE 3: ROOF, COVER OPTIONS _ Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes &Shingles Slate Elastobase Yes Yes (Base sheet In 2-ply system) Yes (Base Sheet in 2-ply system) Yes Yes Yes Elastobase P Yes Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) Yes Yes Yes Polyglass G2 Base No Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) No No No Polyglass APP Base No Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) No No No Polystick MTS or MTS PLUS Yes Yes No Yes Yes Yes Polystick lR-Xe Yes No No No Yes Yes Polystick TUP No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick TU Max No Yes Yes (See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) yes Yes Yes (See 5.5.1) No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE IA: ALLOWABLE TILE ADHESIVE/ UNDERLA_YMENT COMBINATIONS Adhesive Florida Product Underlayments Approval DAP Foam Touch'n Seal StormBond Roof Tile Adhesive FL34506 Polystick TU Plus, Polystick TU Max Dow TileBondT" FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® AH-160 FL6332 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® RTA-1 FL6276 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) t Refer to Tile Manufacturers or Adhesive Manufacturers Florida ProductApproval for Overturning Moment Resistance Performance. NEMO ETC, U.C. Evaluation Report P32060.02.09-R24 Certificate of Authorization#32455 6'"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018 Page 5 of 14 NNEmoletc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System' Panels (designed and installed to meet wind loads for project). Nate: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: ➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization#32455 6'"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 6 of 14 (14NEMO I etc. 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for windload resistancebased on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04- 12), Appendix A, Table 3A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure =-90 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #2 Maximum Design Pressure =-97.5 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure=-105 osf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x IV" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure =-135 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #5 Maximum Design Pressure=-315 Dsf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #6 Maximum Design Pressure=-622.5 Ds : Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG1OO or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #7 Maximum Design Pressure=-30.0 osf*: Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEMO ETC, U.C. Evaluation Report P12060.02.09-R24 Certiflmte of Authorimdon#32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 7 of 14 -CREEK TECHNICAL SERVICES, LLC Oart)flrate-of M 1�or'®tion Nn 29M 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 61H EDITION (2017) Manufacturer. DREXEL METALS, INC. Issued September 14, 2017 1234 Gardiner Lane Louisville, KY 40213 (602)116-7143 v .drertmetcmn Manufacturing: Drexel Metals Association of Regional. Manufachlrers(DM-ARM) 4�C9 Quality Assurance: Amhilechlral Testing, In.(QUA1844) SCOPE �ey-y�0 Co Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year Architectural Testing (TST1558) 56840.02-12248 TAS 100 1995 Architectural Testing (TST1558) 58389.01422-44 UL 580 2006 Am7r3ectrual Testing (TST1558) 53459.01422-44 UL 580 2006 Archdechctl Testing (TST1558) 59461.01-122-04 TAS 125 2003 Architectural Tesling(TST1558) 82776,01-10944 UL 580 2006 UL 1891 2012 Architectural Trsting(TST15S8) 82784.01-10944 UL 580 2006 UL 1897 2012 Architectural Testing (TST1558) 83296.01-109-44 UL 580 2006 UL 1897 2012 Force Engineering & Testing (TST5326) 179-0054T42 UL 680 2006 UL 1897 2012 Force Engineering &Testing (TST5328) 178-0055T-12 UL 580 2006 UL 1897 2012 Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003 Hurricane Test Laboatory(TST7527) 0287-0308-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0311-07 TAS 125 2003 Hurricane Test laboratory (TST1527) 0287-0313-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0287-0512-07 TAS 125 2003 Hurricane Test laboratory (TST1527) 0287-0706-07 TAS 125 2003 PRI Construction Materials Tecludogiss (BT58T8) VLS-005-02-01 ASTM B 117 2016 TAS 110 2000 PRI Construction Materials Technologies (TST5878) VLS-004-02-01 ASTM G 155 2005a TAS 110 2000 PRI Construction Materials Technologies (TST5878) DMC-004-02.01 TAS 125 2003 PRI CorsNstion Materials Tedi clogles (TST5878) DMG-005-02-01 TAS 125 2003 PRI Construction Materials Technologies (TST6878) DMC-006-02-01 TAS 125 2003 PRI Constriction Materials Technologies (TST5878) DMC-007-02-01 TAS 100 1995 PRI Corstniction Materials Technologies (TST5878) 13MC-00&02-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) DMC-009-02-01 TAS 100 1995 PRI Corslr 8 Materials Tedunlogies (TST5878) DMC-014-02-01 TAS 125 2033 PRI Construction Materials Technologies (TST5a78) DMC-01642-01 TAS 100 1995 PRI Construction Materials Technologies (TST5878) DMC-017-02-01 R_ev 1 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies (TST5878) DMG-018-02-01 UL 580 2006 UL 1897 2012 PRI Constnrctlon Materials Technologies (T3T5878) DMC-024-02.01 UL 580 2006 UL 1897 2012 DRX15001A FL1767&R4 P; This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufaetner shall notify CREEK Technical Services, LLC of any product changes or quality assurance charges throughout duration for Witch tits report is valid Tho evaluation report does not express nor ropy vanardy, installation, recommended use. or dher product attributes that am not specifically addressed herein. TECHNICAL SERVICES, LLC Ennttd( RewdNo. PRI Corsbuctlon Materials Tedmkxpes (TST5878) DMC-033-02-01.1 PRI Construction Materials Tectudogles (TST5878) DMC-037-02-01 PRI CwsWrt;on Materials TerJmdogles(TST5878) DMC-037-02-02 PRI Cortructon MateriasTechndogies (TST5878) DMC-038-02-01 PRODUCT DESCRIPTION DREXEL METALS; INC. Metal Roofing Standard Year UL580 2006 UL 1897 2012 UL 580 2006 UL 1897 2012 UL 580 2006 UL 1897 2012 UL580 2006 UL 1897 2012 DMC 10ONS Profile: 1 in. snap lock seam; Max.16 trL coverage Description: Non•struchaal, snap lock standag seam roof panel with integral perorated nail strip Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90; IFY = min. 50 ksi; Shall conform with FBC Section 1507.4.3 I 1S — � n' DMC 150SL Profile: 1.5 im snap lock seam; Max. 16 in. coverage Description: Non-struchuai, amp lack standng seam roof panel Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90; Fr = min. 50 ksl; Shall conform with FBC Section 1507.4.3 DMC 1503S Profile: 1.5 Im mechanical seam; Max. 16 in coverage Description: Non-struchual, mechanical lock stamfmg seam roof panel Material: Mm. 0.032 in. FlumponS coated ASTM B209 alrxnhgrn; Fr = min. 16 ksi; Sing conform with FBC Section 1607.4.3 Mon. 24 ga. Flumpon® coated ASTM A792 AZ50, or ASTM A653 G90; Fv = min. 50 ksi; Stag condorm with FBC Section 1507.4.3 1 r=°= �r-L T DRX15001A This evaluation report Is provided for State of Tec inkal Services, LLC of any product chanl Ttfs evaluation report does not express, nor 1 specfk e- addressed herein. FL77678it4 Page 2 of 5 product approval ender Rule 61020-0. The manufacturer shall notify CREEK afiy assonance changes tlaoughmdOw duration forufth the report Is valid. rnny. iksfalaflon, recommended Ise, or other Product atfntul¢s thpt are not ®CREEK TECHNICAL SERVICES, LLC - — DREXEL-METALS. INC. Metal Roofing APPENDIX A Component Product InstallatlonDetall " - 18 ga. base; 22 ga. bu0edy buseam clip; 120 Im lerygtic tops6der 12 h o.d DMC 200S Continuous Sullenly cup r- / 4 Clips (Coma) 24 ga. Inseam clip DMC 450 Clip e ®® 24 ga. SS In seam clip DMC 45OW Clip Sealants gossR Chem-CaBc 915 Stag be applied incw6s nuo beads alag the seam Fastening Details -Nomerdattee Atladanert DMC 100NS PANEL #10 -13 PHW DMC 100NS Standard. ---DMC 10ONS PANEL -- BOSTIK 70-05A (2 - 3116" BEADS) DMC 700NS Enhanced #10 -13 PHW 7 Tect rdral SerAces, LLC of any product charge; or quafdy assurance changes duoughdd the duration frawtkh INs mpW Is valid Th's evaluation report does not express nor Ir * %arranty, Installation, mcanmended use, or direr product athibudes flat am rnit specifically addressed hereby. ®C, R:E'E K Technical Services, LLC' APPROVED ROOF SYSTEMS DREXEL METALS, INC. Metal Roofing APPENDIX B The following notes shall be observed when using the assembly tables below. i. Maximum Design Pressure .(MDP) was calculated using a 2:1 margin of safety per FBC Section 1604.9. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for Installation detail when the Information Is not explicitly stated for the selected assembly, 4. The on-center.(o.c.) spacing given is the maximum allowable attachment spacing for the rated system. S. Steel Deck shall be designed by others In accordance with FBC requirements and shall be minimum 22 ga (Fy = min.33 ksl) Wide Rib Dock (Type WR) conforming to ANSIISDI-RD7.0 & FBC. 5. Wood Deck shall be designed by others to accordance with FBC requirements and shall be minimum 151324nch thick APA Span -Rated plywood sheathing at maximum 24-Inch span. Roof System Numbers and Definitions -100NS-W# OMC ICONS over Wood Deck Newor Existing) 1605L-W_# DMC 150SL overWood Deck New or Existing) S DMC 150SSwar Steel Deck NeworEx6en 50 •W# DMC 16055 overWood Dock Newer Exbtin b - # DMC175S over Steel Deck New or Existing) -W#; DMC176E over Wood Deck new or Existing) R-U-StSm DMC 200S war Steel Deck New or Existing) 2005- DMC 200S over Wood Deck Newor Existin 450-W# DMC 460 over Wood Deck Newor MU 5V-W DMC 5V over Wood Deck New or Existing) CO - # DMC Corrugated overWood Deck Now or Existing) Approved Systems for DMC 1OONS:over Wood Deck (New or Existing) system No. Deck Fire Barrier Undedayment Roof Panel Panel Attachment DP M 100NS•W7 'Min. 15132 OPTIONAL, As required per 24 On. DMC ICONS DMC ICONS Standard attachmentwith fastener -97.6 COX plywood Vereashleld Solo FBC Max. 16-Inch wide spaced 10.61n. o.c. 100NS•W2 Min: 16132 OPTIONAL As required per 24 ga. DMC ICONS DMC ICONS Standard attachmentwithfasteners -120 CDX plywood Vereashleld Solo FBC Max. 16-Inch vAde spaced 5.25 in. roc. 100N3•W3 Min. 16132' OPTIONAL As required per 24 ga. DMC 10ONS DMC'1CONS. Enhanced attachment Wthfasteners -136 CDX plywood Versashield Solo FBC Max. 16•inch Wde spaced 5.25 In. c DRX15001.4 This evaluation report is provided for State of Florida product approval under Rule51G20.3. The manurecturer shall,rwdfy.CREEK Technical Services,. LLC of any product changes or quality assurance changes throughout the duration forwhich this report is valid. This evaluation report does not express my Imply warranty, installadan, recommended use, or other product attributes that are not specificatly addressed herein.