HomeMy WebLinkAboutPOOL PAPERWORK'/S//-/ ww /vim//�po1��(gv C®y.�p�n_r u/�n�j�pec4/t the / of elgv ju�ne��
ifftPOC®®n SCANNED
Vacuum Breaker BY
(HC-121) St. Lucie County
To SOR
c1n
i
Pressure Test Kit
(HC-PTIn
used here to pressure i
test the system;
Ball Valve
(HC-5210)
NEW,, PLUMBING (�ec�Vaiz
- EXISTING PLUMBING (HO-1790)
Pump.
FILTER
PIG 12.1
COLLECTOR
(COOL)
Ball Valve
(HC-5210)
RETURN.
FROM SOLAR
COLLECTOR
(WARM)
ROOF SENSOR
AUTO
-CONTROL
LP
(Optional)
VALVE CONTROLLER
'� - POOL SENSOR
Install after
this point:
• Chlorinator
° Heater
• Other pool
accessories
(optional)
k-h' or
79
Rating -Search ---- - - - - - - - - - - - -- - -
Page I of I
FLORIDA SOLAR ENERGY CENTER`
.. GeGUng Enzr+�y /tldebendercF
FSEC Collector Search
Instructions: Fill in as many values as desired to select partial or full listings and click on Show Selections.
FSEC Ytl:
Collector Type: ,Select Collector Type
Company: Heliocol A, Inc. """-'—"--"
L. _$howSeleetiogs„_,j [_Show iD,Ezcel.__j I__Resel,{4Defaul!___I
F atings Summary Of FSEC Certified Collectors
01/28/2013
Click on a FSEC Number to see the full page Collector report
Thermal
'thermal
Thermal
Collectors
Glazing Absorber
Gross Performance
Performance
Performance
Area
Low
Intermediate
High
ThermosiphOn
Temperature
Rating
Temperature
Tompera[ure
or Ics
Company Model FSEC
Rating
,y
Rating
Num Nurnb9l Na TyRg M__tcrial
Ceatiny A
Btu/Da gtu ftl etu/Oa Btu ft2Btu
y / /
/ y 2
Da Btu/ff
Nat
hlcli0col
TC 30
Polypropylene
LHost
oss
Energy COeff
USA, Inc. OOQ84s 0
None with W
None 29.42
2S000 SSO
stabilization
9700 330
0 0
Heliocol
USA, Inc.
TC 40 000g49 0
Polypropylene
None inch Uv None
stabilization
41.41
35200 850
13700 330
0 .0
Hollocol
Temperedper
USA, Inc.
CA310a9en 00093 1
weleeC tobds
Selective 2SAS
24400 960
glass Copper fins
19100 750
SSeO 220
iellocol
Tempered Capper tubes
15A, Inc.
Alpha 32 0022
. __3 1
IOw Iron nelded to
Selective 31.98
30900
glass capper fins
970
24200 760
7000 220
ieliocol
ISA, Inc
Aloha 40 0025 1
Tempered Copper tubes
low Iron welded to
glass mpper8ns
Selective 40.06
38500 960
30100 750
8700 220
tclaccl
ISA, Inc.
TC 50 92030 0
PalyP.Pylcne
None ith W
stabilization
None 48.6
41300 650
16300 330
0 0
elloco
SA, Inc.lHeliocol
38 00012C 0
Polypropylene
None withUV
Stabilization
None 36.68
35100 960
12600 340
0 0
SA, Inc.
Helloo" 40 00013C 0
ypropylene
None with Uv
stabilzation
None 40.68
38900 960
14000 340
0 0
Sln ��Ic
leliocol 50 98002 0
None PsthpWpylhOe
None 48.23
46100 960
stabilization
16500 340
0 0
ali0001
Sun Ftiser
Polypropylene
SA, Inc.
40 20}]y 0
None with W
None 40.68
38900 960
14000
stabilization
340
0 0
`II0001
Sun Miser
Polypropylene
,A, Inc.
50 poolee 0
None Toth W
None 48,23
46100 960
16500 340
stabilization
0 0
tiiocol
iA, Inc.
Heliocol 30 0 o
-US 0
polypropylene
None With UV
None 29.15
Stabilization
27900 960
10000 340
O O
ucf. edu/stcp/collector search?action=search&shotv_options=l &debu... 1 /23/2013
HELIOCOL COLLECTOR - CO LkETE TILE - TILE
ADHESIVE GENERAL NOTES: 6063T6Z- ARSHAPEUM.
w.'. , u— , -. v...... .u.
.OADS FOR BUILDING AND OTHER STRUCTURES.
vvl l n
LENGTH
li) 44 Ulm.- 1 q
TAPCON
2. PLANS ARE IN ACCORDANCE WITH 2O17 F.B.C. (6TH EDITION) AND PER MIAMI DADE NOA 15-1201.04.
STAGGERED AS SHOWN
3. POLYPRO ROOF ADHESIVE SHALL BE APPLIED IN COMPLIANCE WITH THE COMPONENT APPLICATION
THIS SHEET
SECTION AND THE CORRESPONDING PLACEMENT DETAILS NOTED IN THE NOA APPROVAL DOCUMENT
AND THE 3M/POLYFOAM POLYPRO ROOF TILE ADHESIVE OPERATING INSTRUCTION AND MANUAL
BOOKLET.
HELIOCOL -
4. TILE ROOF INSTALLATION AND UNDERLAYMENT SHALL COMPLY WITH LATEST FLORIDA BUILDING
COLLECTOR
CODE AND ROOFING APPLICATION STANDARD RAS 120.
TYP
5.3M/POLYFOAM POLYPRO ROOF ADHESIVE COMPLIES WITH THE FOLLOWING CODES: 2014 FLORIDA BUILDING
CODE (STH ED), SOUTH FLORIDA BUILDING CODE BROWARD COUNTY-1999, MIAMI DADE NOA 15-1201.04
r I nrAT1nN nF rnl I F/TnRS Wmi 3MIP01 YFOAM ADHFSNF TS NOT TO RF TNSTALLFD IN WIND 70NF 3.
7. CONNECTIONS AND SPECS PER THIS DRAWING MAY BE USED FOR ALL HELIOCOL COLLECTORS TO RESIST
WIND LOADS AS OUTLINED IN 2017 FBC, CHAPTER 16 FOR UP TO 175 MPH, EXPOSURES'B' OR'C" WIND
VELOCITY PER REQUIREMENTS STATED IN ASCE7-10.
3M/POLYFOAM POLYPRO -NOA SPECIFIC NOTES:
POLYPRO ROOF TILE ADHESIVE MUST BE APPLIED TO AN UNDERLAYMENT INSTALLED IN COMPLIANCE WITH
APPLICATION INSTRUCTIONS DETAILED IN THE FOLLOWING LATEST DOCUMENTS:
FRSAIROOF TILE INSTITUTE ADHESIVE SET TILE SPECIFICATION.
3M/POLYFOAM ADHESIVE IS UL CLASSIFIED AS AN ADHESIVE MIAMI-DADE NOA 15-1201.04, EXPIRES
1/03/2021.
LIMITATIONS OF MIAMI-DADE NOA FOR SPECIFIED TILE PROFILE -ADHESIVE BELOW:
1) FOR ADHESIVE SET TILE APPLICATIONS, A STATIC FIELD UPLIFT TEST IN ACCORDANCE WITH TAS 106
MAY BE REQUIRED, REFER TO APPLICABLE BUILDING CODE.
2) APPLICANT SHALL RETAIN THE SERVICES FOR A MIAMI-DADE COUNTY CERTIFIED LABORATORY TO
PERFORM QUARTERLY TEST IN ACCORDANCE WITH TAS 112, APPENDIX W. SUCH TESTING SHALL BE
SUBMITTED TO THE BUILDING CODE COMPLIANCE OFFICE FOR REVIEW.
3) MINIMUM UNDERLAYMENT SHALL BE IN COMPLIANCE WITH THE APPLICABLE ROOFING APPLICATIONS
STANDARDS LISTED SECTION 4.1 HEREIN.
4) THIS ACCEPTANCE IS FOR WOOD DECK APPLICATIONS. MINIMUM DECK REQUIREMENTS SHALL BE IN
COMPLIANCE WITHAPPLICABLE BUILDING CODE.
TABLE 1: ADHESIVE PLACEMENT FOR EACH GENERIC TILE PROFILE PER MIAMI DADE NOA 15-1201.04
CONCRETE ROOF TILE PROFILE
PLACEMENT DETAIL
MINIMUM SINGLE PADDY
WEIGHT (GRAMS)
FLAT / LOW / HIGH PROFILE
#1 AND #2
12
HIGH PROFILE (2 PIECE BARREL)
#2
12
FOR HIP AND GABLE ROOFS - PLAN r1'
1"x1'x21"-16'ALUM
6063T6 Z-BAR SHAPE
WITH (1) A" DIA. -14.
LENGTH TAPCON
STAGGERED AS SHOWN
THIS SHEET
END CAP HtLLUWL. LLAMF�
TYP, CONNECTION (SEE NOTE**)
4'-0" TYP. 24" O.C. PER COLL. TYP.
TYPICAL (5) COLLECTOR ARRAY PLAN
SCALE: 41"=1'-0"
(2 MINIMUM) TYP.
RECEIVED
JAN 17 2019
ST. Lucie County, Permitting
1" X Z' X 2 %" -16' ALUM. 6063T6 Z-BAR SHAPE (30"
MIN. SECTIONS) FASTENED WITH (1) 41 DIA. -1 4'
LENGTH TAPCON 12" O.C.
1 f.
22 I f
HELIOCOL CLAMPS —1N 32°
(2 MINIMUM) TYP.
TYPICAL MAR DETAIL
** CLAMP CONNECTION NOTE:
1. WHEN CLAMP FALLS OVER TILE: USE (1) aDIA. -1 q" LENGTH TAPCON THRU
Z-BAR INTO TILE.
2. WHEN CLAMP FALLS OVER VALLEY: USE (1) 4" DIA. - V LENGTH ST. STL. BOLT -
WASHER- NUT THRU Z-BAR
(2) #6 HEX SCREWS
- a" LENGTH TYP
1" x 2" x 2 Y2" -16" ALUM.
CLAMP
6063T6Z-BAR SHAPE TYP
CONNECTION
TOP & BOTTOM OF
SEE NOTE **
COLLECTOR WITH (1) q"
DIA. -14.
LENGTH TAPCON
STAGGERED 12" O.C.
(SEE Z-BAR DETAIL)
FLAT CCNC.'
TILE TYP.
APPLY 3M/POLYPRO ROOF TILE
#2 S.Y.P. ADHESIVE, OR EQUAL, TO ADHERE
WOOD ROOF BOTTOM SIDE OF TILE HELIOCOL
TRUSS TYP. CLAMP IS ABOVE TO PLUS ALL
WOOD TILES AROUND IT (S MIN.)
SHEATHING
TYPICAL FLAT / LOW PROFILE CONCRETE TILE
ADHESIVE TOP & BOTTOM CONNECTION DETA
SCALE: 1"=1'-0"
ST. LUCIE COUNTY -
BUILDING DIVIsIoN
REVIEWED
FOR OOMPL,Ipi11CCT
REVIEWED13Y �{{((�7
DATE
PLANR IT
MUST ME KEPT ON J09 OR
SCANNED
BY
St. Lucie County
Li
0
UI•I.
1" x Z" x 2 %" - -L" ALUM. /� 0 03 6063T6 - E TYP.
6063T6 Z-BAR SHAPE TYP (2) #6 HEX SCREWS
3" HELIOCOL CLAMP
TOP &BOTTOM OF q LENGTH TYP
COLLECTOR WITH (1) q" CLAMP SPACED 2' 0" O.C.
TYPI
DIA. z 1 q" CONNECTION -
LENGTH TAPCON SEE NOTE **
STAGGERED 12" O.C. 4' DIA. -1 q' LENGTH
(SEE Z-BAR DETAIL) TAPCON STAGGERED
' 12" D.C. TYP.
HIGH CONC.
TILE TYP.
#2 S.Y.P. APPLY 3M/POLYPRO ROOF TILE
WOOD ROOF ADHESIVE, OR EQUAL, TO ADHERE
BOTTOM SIDE OF TILE HELIOCOL
TRUSS TYP. CLAMP IS ABOVE TO PLUS ALL
WOOD TILES AROUND IT (5 MIN.) TVDT/"AI 7-PAD
-
a
h
Z
0
V
F
o
w
LD
a
_�
Tr3rhI
;
_ WPI
SHEATHING
TYPICAL HIGH PROFILE CONCRETE TILE CLAMP CONNECTION
ADHESIVE TOP & BOTTOM CONNECTION DETAIL 4 DETAIL
SCALE: 1"=1'-0" HC 6 SCALE: 1/2"=1'-0"
061
I PROJECT:
o z
x¢
Uz
as
U z
gO
cn �
a¢
ri5
c
Oc Fw
t5 F¢-
J LU w
J J Q
U 1
w ¢ U
w w
n
wIX) 0�
S U m d 2
DATE 7-19-17
DRAWN BY: JAT
CHKD BY: JAT
REG N0.# 29127
SCALE AS NOTED
APR 0 A 2018