HomeMy WebLinkAboutNOAMIAMI, - - MIAMI-DADE COUNTY
M939PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Sheet, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv
J.A. Taylor Roofing, Inc. FILE
COPY 13 1
vim�Cj
302 Melton Drive
Fort Pierce, FL 34982 $
. t Lucie Coun
ty
SCOPE: It: Iew.�i- l`t a (- � 3 y-()
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction., RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:.032" Aluminum (min) 5-V-Crimp Panel over''V2" (min) plywood
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages I through 5.
The submitted documentation was reviewed by Gaspar J Rodriguez.
4,,.4A-
MIAMI•DAnE COUNTY NOA No.: 16-0224.09
Expiration Date: 0324/21
Fluffem Approval Date: 0324/16
Page 1 of 5
ROOFING SYSTEM APPROVAL:
Category:
Sub -Category:
Material:
Deck Type:
Maximum Design Pressure:
Roofing
Metal, Panels (Non -Structural)
Aluminum
Wood
-176 PSF
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test
Product
Product Dimensions Specifications Description
.032" Aluminum L = varies TAS 110
.032" (min.) Aluminum preformed metal
S-V-Crimp Metal W = 20.5"-24"
panels, painted or unpainted.
Roof Panel H = %:"
Min. Thickness: 0.032"
Min Yield Strength: 23 KSI
Fasteners # 10 HWH of sufficient TAS 110
Stainless steel screw with capped hex head
length to penetrate through
bonded washer.
sheathing a minimum of 3/16'
Trim Pieces L = varies TAS 110
Standard flashing and trim pieces.
W = varies
Manufactured for each panel width.
Min. Thickness: 0.032"
EVIDENCE SUBMITTED:
Test Agency Test Identifier
Test Name/Report Date
Architectural Testing, Inc. D9330.01-450-18
TAS 100 10/13/14
D9330.03-450-18
TAS 125 10/13/14
Valspar 433X515
ASTM B 117 11/21/11
433B173
ASTM D 4587, ASTM G 23 11/21/11
NOA No.: 16-0224.09
Expiration Date: 03/24/21
Approval Date: 03/24/16
Page 2 of 5
APPROVED ASSEMBLIES:
System A: 0.032" Aluminum 5-V-Crimp Metal Roof Panel —
HORIZONTAL LAPS ARE PERMITTED
Deck Type: Wood, Non -insulated
Deck Description: New Construction 19/32" or greater plywood or wood plank, or for re -roofing 15/32" or
greater plywood.
Maximum UDlift Pressure: See Table A below.
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6" o.c. In reroofing, where the deck is less than 11/32" thick
(minimum 15/32") the above attachment method must be in addition to existing
attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4"
side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -
caps and 12 gauge 1 '/4" annular ring -shank nails, spaced 6" o.c. at all laps and two
staggered rows 12" o.c. in the field of the roll or any approved underlayment having a
current NOA.
Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory
listing for fire ratings of this roofing system assembly as well as the location of the fire
barrier within the assembly. See Limitation # 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133
and with PAC Contractors Association's current published installation instructions.
Metal Panels and Install the ".032" Aluminum 5-V-Crimp Metal Roof Panels" and accessories in
Accessories: compliance with PAC Contractors Association's current published installation
instructions and details. Flashing, penetrations, valley construction and other details
shall be constructed in compliance with the minimum requirements provided in Roofing
Application Standards RAS 133.
Panels shall be fastened with corrosion resistant #10 HWH screws of sufficient length to
penetrate through the sheathing a minimum of 3/16". Fasteners shall be installed parallel
to the roof slope along the panel's overlapping ribs (fastening of the center rib is
optional) at a maximum spacing as listed in Table A below.
TABLE A
MAXIMUM DESIGN PRESSURES
Field
Perimeter and Corner'
Maximum Design Pressure
-74.75 PSF
-176 PSF
Maximum Fastener Spacing
16" OC
8" OC
1. Extrapolation shall not be allowed
NOA No.: 16-0224.09
Expiration Date: 03/24/21
Approval Date: 03/24/16
Page 3 of 5
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended comers and corners).
3. Panel shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be described in the
Roofing Application Standard RAS 133. HORIZONTAL LAPS ARE PERMITTED
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city and state of
manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or with
the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the
manufacturer's name and/or logo, and/or model.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
6. Panels may be shop or jobsite roll formed with machine model #RF6271 from PAC Contractors Association.
NOA No.: 16-0224.09
Expiration Date: 03/24/21
Approval Date: 03/24/16
Page 4 of 5
PROFILE DRAWINGS
STIFFENING RIBS AND/OR STRIATIONS ARE OPTIONAL
■
DESCRIPTION,GENERAL PANEL
PANEL MATERIAL
Steel & Alurriinwn
MIN. PANEL THICKNESS
24go 8.03T Aluminum
PANEL WIDTH
20.5' to 24 0"Coverage
PANEL 03 HEIGHT
318' Minimum
PANEL FASTENERS:
910 Hex 'Heac':car" $cm'ks
w.'r6'eerher
SMmrjg Rbs & Pend Sbizfi r are Optional
n ucsihc5c puipuscs, Sesteriom
0m dontui riu aru cpiluiial
ePAC CONTRACTORS
F
ACCEPTANCEEND OF THIS
NOA No.: 16-0224.09
Expiration Date: 03/24/21
Approval Date: 03/24/16
Page 5 of 5