HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FILE COPY pS1 hF9D g1019 "�% aA0 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING COI'RUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Reels Residence Street: 5180 NW Dunn Road Builder Name: Robert M. Reals Permit Office: St. Lucie County n �•y,YrVq City, State, Zip: Fort Pierce , FL , 34983 Permit Number. 1901-0370a7f �v Owner. Robert M. & Leah N. Reals Jurisdiction: St. Lucie County (��,�� Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) Co 1. New construction or existing New (From Plans) 9. Wall Types (2600.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2170.00 ft' b. Frame - Wood, Adjacent R=11.0 430.00 ft- 3. Number of units, if multiple family 1 c. NIA R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types (2589.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2589.00 ft= 6. Conditioned floor area above grade (ft') 2589 b. N/A R= ft' Conditioned floor area below grade (ft') 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(368.0 sgft.) Description Area a. Sup: Attic, Rel: Attic, AH: Attic 6 130 a. U-Factor: Dbl, U=0.65 204.00 ft' SHGC: SHGC=0.25 b. U-Factor. Dbl, U=0.65 164.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 42.0 SEER:16.00 c. U-Factor. NIA ft' SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor. N/A ft' a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 6.344 ft. Area Weighted Average SHGC: 0.272 14. Hot water systems 8. Floor Types (2589.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab-On-Gmde Edge Insulation R=0.0 2589.00 ft' b. Conservation features EF: 0.950 b. N/A R= ft' None c. N/A R= ft' 15. Credits CF, Pstat Total Proposed Modified Loads: 83.43 Glass/Floor Area: 0.142 PASS Total Baseline Loads: 85.58 1 hereby certify that the plans and specifications covered by Review of the plans and S7,1T6 this calculation are in compliance with the Florida Energy specifications covered by this 04-04E Code. calculation indicates compliance 'n �, �o•W 1 with the Florida Energy Code. s�`-a ;,::rw;.,•i „ O PREP D y: Before construction is completed a �� DATE: - this building will be inspected for compliance with Section 553.908 O Y a I hereby certify that this building, as designed, is in compliance Florida Statutes. 1,1, with the Florida Energyi4::Z COp WS OW NEWAGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 2/1/2019 4:59 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Reels Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2589 Lot # Owner Name: Robert M. & Leah N. Reels Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Robert M. Reels Rotate Angle: 0 Street: 5180 NW Dunn Road Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce, Family Type: Single-family FL, 34983 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2589 25890 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Bath 2 60 600 No 0 1 Yes Yes Yes 2 Bedroom 2 192 1920 No 1 1 1 Yes Yes Yes 3 Bath 98 980 No 0 1 Yes Yes Yes 4 Great Room 680 6800 No 0 1 Yes Yes Yes 5 Nook 143 1430 No 0 1 Yes Yes Yes 6 Master Bedroom 256 2560 No 1 1 1 Yes Yes Yes 7 Master Bath 148 1480 No 0 1 Yes Yes Yes 8 Toilet 28 280 No 0 1 Yes Yes Yes 9 Master Closet 88 880 No 0 1 Yes Yes Yes 10 Utility 64 640 No 0 1 No Yes Yes 11 Kitchen 252 2520 Yes 1 1 Yes Yes Yes 12 Hall 32 320 No 0 1 No Yes Yes 13 Pantry 48 480 No 0 1 Yes Yes Yes 14 Study 156 1560 No 0 1 Yes Yes Yes 15 Bedroom 3 174 1740 No 1 1 1 Yes Yes Yes 16 Closet 2 42 420 No 0 1 Yes Yes Yes 17 Closet 40 400 No 0 1 No Yes Yes 18 Hall 88 880 No 0 1 No Yes Yes 211/2019 4:59 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS - - - # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bath 2 16 it 0 60 ft' __ 1 0 0 2 Slab -On -Grade Edge Insulatio Bedroom 2 16 it 0 192 ft' __ 1 0 0 3 Slab -On -Grade Edge Insulatio Bath 7 ft 0 98 ft2 -_ 1 0 0 4 Slab -On -Grade Edge Insulatio Great Room 44 ft 0 -680 ft2 1 0 0 5 Slab -On -Grade Edge Insulatio Nook 20 It 0 143 fl2 ___ 1 0 0 6 Slab -On -Grade Edge Insulatio Master Bedroom 20 It 0 256 ft' — 1 0 0 7 Slab -On -Grade Edge Insulatio Master Bath 16 ft 0 148 ft' — 1 0 0 8 Slab -On -Grade Edge Insulatio Toilet lift 0 28 ft2 — 1 0 0 9 Slab -On -Grade Edge Insulatio Master Closet 8 it 0 88 ft2 — 1 0 0 10SIab-On-Grade Edge Insulatio Utility t ft 0 64 ft2 1 0 0 11SIab-On-Grade Edge Insulatio Kitchen E ft 0 252 112 __ 1 0 0 12SIab-On-Grade Edge Insulatio Hall 1 1 ft 0 32 ft2 — 1 0 0 13SIab-On-Grade Edge Insulatio Pantry 3 it 0 48 112 __ 1 0 0 14SIab-On-Grade Edge Insulatio Study 18 ft 0 156 ft2 -_ 1 0 0 15SIab-On-Grade Edge Insulatio Bedroom 3 25 ft 0 174 ft2 -_ 1 0 0 16SIab-On-Grade Edge Insulatio Closet 2 7 it 0 42 112 1 0 0 17SIah-On-Grade Edge Insulatio Closet 3 1 It 0 40112 _- 1 0 0 18SIab-On-Grade Edge Insulatio Hall 2 1 it 0 88 112 _- 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2895 ft2 0 ft2 Light 0.6 No 0.9 No 20 26.6 ATTIC v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2589 fF N N 211/2019 4:59 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Unvented) Bath 2 20 Blown 60 ft2 0.1 Wood 2 Under Attic (Unvented) Bedroom 2 20 Blown 192 ft2 0.1 Wood 3 Under Attic (Unvented) Bath 20 Blown 98 ft' 0.1 Wood 4 Under Attic (Unvented) Great Room 20 Blown 680 ft2 0.1 Wood 5 Under Attic (Unvented) Nook 20 Blown 143 ft2 0.1 Wood 6 Under Attic (Unvented) Master Bedroom 20 Blown 256 ft- 0.1 Wood _ 7 Under Attic (Unvented) Master Bath 20 Blown 148 ft2 0.1 Wood 8 Under Attic (Unvented) Toilet 20 Blown 28 fN 0.1 Wood _ 9 Under Attic (Unvented) Master Closet 20 Blown 88 ft2 0.1 Wood 10 Under Attic (Unvented) Utility 20 Blown 64 ft2 0.1 Wood 11 Under Attic (Unvented) Kitchen 20 Blown 252 ft2 0.1 Wood 12 Under Attic (Unvented) Hall 20 Blown 32 ft2 0.1 Wood 13 Under Attic (Unvented) Pantry 20 Blown 48 ft2 0.1 Wood 14 Under Attic (Unvented) Study 20 Blown 156 ft2 0.1 Wood 15 Under Attic (Unvented) Bedroom 3 20 Blown 174 ft2 0.1 Wood 16 Under Attic (Unvented) Closet 20 Blown 42 ft2 0.1 Wood 17 Under Attic (Unvented) Closet 3 20 Blown 40 112 0.1 Wood 18 Under Attic (Unvented) Hall 20 Blown 88 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo S Pace w 1 N Exterior Concrete Block - Ext Insul Bath 2 4.1 10 0 10 0 100.0 ft2 0 0 0.6 0 -2 E Exterior Concrete Block - Ext Insul Bath 2 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 -3 N Exterior Concrete Block - Ext InsLBedroom 2 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 -4 E Exterior Concrete Block - Ext InsiBedroom 2 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 _ 5 E Exterior Concrete Block - Ext Insul Bath 4.1 7 0 10 0 70.0 112 0 0 0.6 0 _ 6 E Exterior Concrete Block - Ext InsGreat Room 4.1 20 0 10 0 200.0 ft2 0 0 0.6 0 _ 7 W Exterior Concrete Block - Ext InsGreat Room 4.1 24 0 10 0 240.0 ft2 0 0 0.6 0 _ 8 N Exterior Concrete Block - Ext Insul Nook 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 _ 9 E Exterior Concrete Block - Ext Insul Nook 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 _ 10 N Exterior Concrete Block - Ext In3d6ster Bedro 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 _ 11 E Exterior Concrete Block - Ext InMaster Bedro 4.1 16 0 10 0 160.0 ft2 0 0 0.6 0 _ 12 E Exterior Concrete Block - Ext InsMaster Bath 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 _ 13 S Exterior Concrete Block - Ext InsMaster Bath 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 _ 14 E Exterior Concrete Block - Ext Insul Toilet 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 _ 15 S Exterior Concrete Block - Ext Insul Toilet 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 _ 16 S Exterior Concrete Block - Ext In9fster Closet 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 _ 17 W Exterior Concrete Block - Ext Insul Kitchen 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 18 W Exterior Concrete Block - Ext Insul Pantry 4.1 3 0 10 0 30.0 ft2 0 0 0.6 0 _ 19 S Exterior Concrete Block - Ext Insul Study 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 20 W Exterior Concrete Block - Ext Insul Study 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 21 N Exterior Concrete Block - Ext InsxBedroom 3 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 22 W Exterior Concrete Block - Ext InsrBedroom 3 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 2/1/2019 4:59 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS - -- ---- - Adjacent Cavity Width Height Sheathing Framing Solar Belo S Pace w 23 N Exterior Concrete Block - Ext InsulCloset 2 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 24 N Garage Frame - Wood Master Closet 11 11 10 110.0 ft2 0 0.25 0.600000 0 25 N Garage Frame -Wood Utility 11 8 10 80.0 ft2 0 0.25 0.600000 0 26 N Garage Frame - Wood Hall 1 11 4 10 40.0 ft2 0 0.25 0.600000 0 27 N Garage Frame -Wood Kitchen 11 9 10 90.0 ft2 0 0.25 0.600000 0 28 N Garage Frame -Wood Pantry 11 11 10 110.0 ft2 0 0.25 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood Great Room None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Im Shade Screening 1 E 2 Metal Low-E Double Yes 0.65 0.25 N 7.3 R2 10 it 0 in 1 ft 4 in None None 2 E 4 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft 1 It 7 in 1 It 4 in None None _ 3 E 5 Metal Low-E Double Yes 0.65 0.3 N 22.7 ft2 10 It 0 in 1 ft 4 in None None 4 E 6 Metal Low-E Double Yes 0.65 0.3 N 96.0 ft- 10 ft 0 in 1 ft 4 in None None 5 W 7 Metal Low-E Double Yes 0.65 0.25 N 36.0 ft- 5 ft 0 in 1 ft 4 in None None 6 W 7 Metal Low-E Double Yes 0.65 0.25 N 18.7 ft- 5 It 0 in 1 It 4 in None None 7 N 8 Metal Low-E Double Yes 0.65 0.3 N 22.7 ft2 10 It 0 in 1 ft 4 in None None 8 E 9 Metal Low-E Double Yes 0.65 0.25 N 20.0 ft2 1 It 7 in 1 It 4 in None None 9 N 10 Metal Low-E Double Yes 0.65 0.3 N 22.7 1110 It 0 in 1 ft 4 in None None 10 E 11 Metal Low-E Double Yes 0.65 0.25 N 20.0 ft2 1 It 7 in 1 ft 4 in None None 11 S 13 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft2 1 ft 7 in 1 ft 4 in None None 12 W 17 Metal Low-E Double Yes 0.65 0.25 N 36.0 ft2 5 It 0 in 1 ft 4 in None Node _ 13 W 20 Metal Low-E Double Yes 0.65 0.25 N 18.0 ft2 1 ft 7 in 1 ft 4 in None None 14 W 22 Metal Law-E Double Yes 0.65 0.25 N 18.0 ft2 1 ft 7 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 484 ft2 484 ft2 43 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 3020.5 165.82 311.85 .3446 7 211/2019 4:69 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM -- --- — # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None CORI 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split SEER: 16 42 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS _ / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 130 ft- Attic 35 f12 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Crreiling Fans: Cooling Vent ng Jan Feb Mar Jan Feb Mar �A Jun Jul Aug fr r Nov rr Dec l l l l lxJ Apr [ May Jun Jul Aug [ Sep Oct lxl Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/1/2019 4:59 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS - Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 Bath 2 Default(8 lbs/sq.ft. ft' ft 0.3 Bedroom 2 Default(8 lbs/sq.ft. ft' ft 0.3 Bath Default(8 Ibs/sq.ft. ft' ft 0.3 Great Room Default(8 lbs/sq.ft. ft' ft 0.3 Nook Default(8 lbs/sq.ft. ft' ft 0.3 Master Bedroom Default(8 Ibslsq.ft. ft' H 0.3 Master Bath Default(81bs/sq.ft. ft' ft 0.3 Toilet Default(8 Ibs/sq.ft. ft' ft 0.3 Master Closet Default(8 lbs/sq.ft, ft' ft 0.3 Utility Default(8 lbs/sq.ft. ft' ft 0.3 Kitchen Default(8 lbs/sq.ft. ft' ft 0.3 Hall Default(8 lbs/sq.ft. ft' ft 0.3 Pantry Default(8 lbs/sq.ft, ft' ft 0.3 Study Default(8 Ibs/sq.ft. ft' ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft' ft 0.3 Closet 2 Default(8 lbs/sq.ft. ft' ft 0.3 Closet 3 Default 8 Ibs/s .ft. ft' ft 0.3 Hall 2 Name: Signature: Rating Compant: Date: �l 2/1/2019 4:59 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Reels Residence Builder Name: RobertM. Reals Street: 5180 NW Dunn Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34983 Permit Number. 1901-0370 X Owner. Robert M. & Leah N. Reels Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce 0 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier, not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with oeilin /soffit The insulation in an dropped9 the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind rimpina and wirino. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricalfphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids fire sprinkler cover plates and walls or cellincts. a. ni auuuwn, inspection of iog watts snau De in accordance wlm me provisions or Ile:-4uu. 2/1/2019 5:00 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 42.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2589 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.272 14. Heating system: Capacity 34.0 c) Area 7c. 368.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 20.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Muitizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: s// / Date: Address of New Home: 5180 NW Dunn Road City/FL Zip: Fort Pierce, FL 34983 2/1/2019 5:00:22 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 + wrightsoftProject Summary Quick Calcs, Inc. Job: FILE -C e: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: qulckcalcs@aol.com For: Reels Residence XXX NW Dunn Road, Fort Pierce, FL 34983 SCANNr-m Notes: PY St. Luce County Design Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 of Outside db 90 'F Inside db 70 of Inside db 75 'F Design TD 28 °F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 30820 Btuh Ducts 5607 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 36428 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ft2) 2589 2589 Volume (ft) 25890 25890 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 138 69 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 10.7 kW 36476 Btuh 24 °F 1400 cfm 0.038 cfm/Btuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 27541 Btuh Ducts 3831 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 29803 Btuh Latent Cooling Equipment Load Sizing Structure 4284 Btuh Ducts 3040 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 7324 Btuh Equipment Total Load (Sen+Lat) 37127 Btuh Req. total capacity at 0.70 SHR 3.5 ton Cooling Equipment Summary Make Carder Trade CARRIER Cord CA16NA0420000A0 Coil FX4DNF049L AHRI ref 9199824 Efficiency 13.0 EER, 16 SEER Sensible cooling 29400 Btuh Latent cooling 12600 Btuh Total cooling 42000 Btuh Actual air flow 1400 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. =lghtsoft- 2018-Deo-1709:27.41 RightSuite® Universal 201818.0.19 RSU08101 Paget ...ADocuments\Wrightsoft FNACIReals Residence.rup Colo =MJ8 Front Door faces: W m �J 2C G ',,. ' awmgg . II I ��fIIl�f�flTr� ' lift I III t3 I� l �. III III i III III Yi ld5�E1 .. t III � IIII zly i _Ie. I'll 'L�it tt IIIN III I Li 03 L m C m .. E& � �fr[TC �i P i Ili i nIC tnt it I, i iuuun�.i n i'iu u i i i �� 'i l i i 11 11111 1 1 l i 89 ill E i._� ill ill 111 11111 sil Ir if J " .1. d d O ; T - G Im i"°°mi��lill l � i i 111 i _-11 '�`3 "II�II'''II l� li`II''Illllllhl ^ .Ia � :21% � �, 11 I.I i111111 �l � lei 1111 IIII � 1 ll7 II �s _ii } �I111 1.1E nri�{4 3ta 3il��� it �1,r�wlu j i.;�!a.! tin,. I� IIIII I IIIIII�i't 3 + wrightsoft Right-M Worksheet Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: qulckcalcs@aol.com Job: Date: by: 1 2 3 4 5 Room name Exposed wall Room height Roam dimensions Room area Master Bedroom 20.0 It 10.0 ft heattwol 16.0 x 16.0 If 256.0 ft2 Master Bath 16.0 it 10.0 ft heat(cool 1.0 x 148.0 It 148.0 ft- I I Ty Construction number U-value (Bluhlft? °F i Or HTM I (Btuh/ft2) Area (ft-) I or perimeter (ft) Load I (Btuh) Area (ft2) I or perimeter (ft) Load I (etuh) i Had I Cool Gross WP/S j Heat I Cool I Gross I WP/S Heat Cool III--6-TTVVy---y 11 _ G 13A-flocs .10D7m 13A-4ocs 10D-m 4A5-2om 4AS20m 4A5-20m 4A5-2omd ,IB5-21fm 13A-40m IA5­2om 73A-0ocs 4A5-tom 4AS-2om 4AS2om 11DO -1Li -6X19-0md 22A-al 0.143 v1.390 0.143 1.390 0.770 0.770 0.770 0.770 0.590 0.143 -0.770 0.743 0.170 0.770 0.770 __--0.390 _0A08 0.989 - n ,n_ a a a a a a a s -s_ 4.00 _.38.92 4.00 38.92 21.56 21.56 21.56 21.56 16.52 � 4.00 _21. 2.19 _20.03 2.19 22.46 46.95 46.95 46.95 22.78 16.82 - 2.19 -19.31, 40 __23 160 0 20 0 0 0 0 17 _0-882 140 0 0 0 0 0 0 69 561 0 431 0 0 0 0 38 454 306 0 939 0 0 0 0 0 -0 40 0 0 0 0 0 0 0 _0 __0 0 0 :_-0 88 0 0 0 0 0 0 40 0 0 0 0 0 0 160 0 0 0 0 0 0 420 _323 -Vy - �-G 0 -0 0 �0 0 0 0 0 120 .�_15 105 �15 230 __290 w w w w vi_ _-_, - 21.56 1.56 21.56 21.56 10.92 �1.59. 27.69 256 .19 4.97 33.90 37.20 10.34 _1.37 0.00 0 0 0 0 0 0 0 0 0 0 �.,-256 20 0 0 0 -0 0 _406 554 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _202 0 . ,C� F _256 256 _350 0 48 148 _148 16 .�235. 443 61 c) AED excursion -128 -07 Envelope loss/gain 2903 1959 1 1 1582 762 12 a) Infiltration b) Room ventilation 392 0 105 0 313 0 84 0 13 Internal gains: Occupants@ 230 Appliances/other 1 230 0 0 0 0 Subtotal (lines 6 to 13) 3295 2294 1 1895 846 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 18% 14% 0 0 10 3305 607 0 0 8 23102 320 18% 14% 0 0 0 1895 345 0 0 0 846 118 Tolal room load Air required (ctm) I I 31106 I 750I 2622 1171 I 2240 I 861 964 43I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ��'19h+tso• ft" 2018-Deo-1709:27:41 A Rlea[s Ro le®Universal 2018 78.0.19 RSU dace Page 4 ... r\Oo<uments\Wrightsoft HVAC\Reels Residen<e.mp CaIc=MJe Front Door laces: W III Il ill111111 ili�[YC�[[[['C fi �i�i�li 4l90 NO << �Isr80 l20�t >f � � �IVlillllll�ll�l�lllllsl� P,� 3• iuuiiiiu ii nu i �� I� III III III � � �i 11 111111111 I ill III_ III-I°sal __ .. UJ. . . . . I J Ii J I F 11 n .e.<. x.. i ii i I .,.,,:J.,,.,.,'.JM� 3 US Li z s d « p m T �om 777 IIII III I II III ICII II l 11i r li i'. I ill i i i 01 o I 1 111111111111111 11 11 Yi =ill III - ' , :,' � III�I I II II IIII 7 i II'ta III I II f} � III III l� �- 111 IIIII Ilt i� ifi 3 e �U.il�_.�. • I I LI_I Ill lli II I 'wO I•�3.+� WX WO WO _���� + wrightsoftRight-J® Worksheet Quick Calcs, Inc. 317 St Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcales@aol.com Job: Date: By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Hall 0 ft 10.0 ft heatf000l 4.0 x 8.0 it 32.0 ft' Pantry 3.0 It 10.0 it heat/cool 6.0 x 8.0 ft 48.0 ft- Ty Construction number U-value (Btulditi'F I Or I -(BtHTM uh/fP) I Area (W) or perimeter (ft) I Load (Btuh) I Area (fP) I or perimeter (ft) Load (Btuh) Huai Cool Gross N/P/S Heat Cool Gross N!P/S Heat Cool 6 `G A4ocs _10Dr. 0.143 _1.390 n _n_ 4.00 -38.92 2.19 20.03 ' 0 __0 0 0 0 0 0 0 0 0 0 0 0 -0 0 __0 11 13A-4ocs 106m 4A5-2om 4A5.20m 4A5-2om 4A5.2omd 4B6;2fm 13A<ocs 4A5-2om 0.143 1.390 0.770 0.770 0.770 0.770 T0.590 0.143 -0.770 a a a a a a e_ s -s_ 4.00 38.92 21.56 21.56 21.56 21.56 16.52 4.00 -21.56 2.19 22.46 46.95 46.95 46.95 2278 _i6.82 219 - 19.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 `G 0 _._0 0 _0 0 -0 0 0 0 -0 0 -0 0 -0 13A30 4A5-2om 4A5-2om 4A5-2om 11DO :16X19-0mtl 22A-tpl 0.143 0.770 0.770 0.770 0.390 ___,0.408 w w w w = �,_ 4 .00 2.56 21.56 21.56 10.92 =.59 2.19 46.97 33.90 37.20 10.34 _1.37. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 30 0 0 0 ��a :48 30 0 0 0 0 120 0 0 0 0 66 6 0 0 0 _ .C_ F -32 -32 -51 44 48 3 -76 83 _66 0 0.989 27.69 0.00 32 0 0 0 48 61 c) AEG excursion Envelope loss/gain 51 41 279 124 12 a) Infiltration b) Roomventila8on 0 0 0 0 59 0 16 0 13 Internal gains: Occupants@ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 51 41 338 139 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 18% 14% 0 0 51 0 0 0 0 41 0 0 18% 14% 0 0 0 338 62 0 0 0 139 19 AirlraGuuedl(cfm) I I I 011 001 I I 415I 157I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -F}'- =2011_rrtes- 2018-Deo-1709:27:41 .Oft Mill Universe1201818.0.19 RSU08101 Page ...ADocumentsUrightsoft HVAC\Reals Residence.mp Cale =MJ8 Front Door faces: W 0 3 9 I. III 0 .I� Hil I1111111N�s ICI' TIy III il 111111 I111111 1 III. ••f i�ii III I III _ gi' III III III � III I. F; 'III I II I III I_il .i us 2 §I III EEE�E III III 4 fii " 3 1i19 E 3! iq�b III Ili <'. Is02. '3 l��li is: J.Jar iiii�o lii.l q��, I III III II 3 +� wrightsoftN Right-M Worksheet Job: Date: By. Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.wrn 1 2 3 4 5 Room name Exposed wa0 Room height Room dimensions Room area Closet 2 7.0 ft 10.0 ft heaV000l 6.0 x 7.0 ft 42.0 fix Closet 3 0 ft 10.0 ft heattmot 8.0 x 5.0 ft 40.0 fl2 Ty Conslmction number ue U-val'F (atuNft%1y I Or I HTM (Btuh/W) Area (ft.) I or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heal Cool Gross N/P!S Heal Cool Gross N/PIS Heal Cool r-� 6 V�-.13A-4om _1-G 10D.m_ 0.143 __1.390 n _n_ 4.00 -38.92. 2.19 -20.03 70 _0 70 _a 280 0 153 __0 0 _w,0 0 . 0 0 0 0 0 71 13A-4= 10D-m 4A5-2om 4AS20m 4A5-2om 4A5.2omd 4B5_2fm 13A�10as 4A5-2om 13A4ocs 4A5-tom 4A5-2om 4A5-2om 11D0_ .10X19-0mtl 22A-Ipl 0.143 1.390 0.770 0.770 0.770 0.770 0.590 0.143 -0.770 0.743 0.170 0.770 0.770 0.390 �0.408 0.989 a a a a a a ,ea s -a_ w w w w w = 4.00 38.92 21.56 21.56 21.56 21.56 16.52 '4:00 -21.56 1. 21.5656 21.56 21.56 70.92 _1.69 2.19 22A6 46.95 46.95 46.95 22.78 16.82 2.19 _19.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 sW L-G 0 0 0. ______0 0 - 0 0 -0 0 0 0 0 0 -0 0 0 2.19 4.97 33.90 3720 10.34 1.37. 0 0 0 0 0 ___42 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _55 0 - F -42 -67 _67 40 40 _.___r63 27.69 0.00 42 7 194 0 40 0 0 61 c)AED excursion -13 S Envelope loss/gain 541 198 63 52 12 a) Infiltration b) Rminventilatian 137 0 37 0 1 0 1 0 0 0 13 Internal gains: Occupants@ 230 Applianceslother 0 0 1 0 0 1 1 0 0 Subtotal (lines 6 to 13) 6781 2341 1 1 63 52 14 15 Less external lead Less transfer Redistribution Subtotal Duct loads 18% 14% 0 0 0 678 123 0 0 0 234 33 18% 14% 0 0 18 82 15 0 0 75 67 9 I end To relqu edl(ofm) Air I I I 831I 212 71 I I 94I 73 61 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -►{� =nollr mo 201&Dec-1709:27.41 RightSuite® U niversal 2018 18.0.19 RSU08101 Page 9 ...ADoeumentslWrightsoft HVACIReals Residence.rup Cale=MJ8 Front Door faces: W + wrightsoft Right-M Worksheet Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com Job: Date: By. 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Han 0 ft 10.0 it heat/cool 11.0 x 8.0 It 88.0 fP Ty Construction number U-value I (Btuh/fP--°F19 I Or I HTM (Btuh/ft')' I Area (ft.) or perimeter (ft) I Load I (Bluh) Area _I or perimeter Load Heat Cool Gross N/P/S Heal I Coal Gross N/PB Heal Cool 6 1--G 13A4ocs -10D-m - 0.143 7.390 s -n_ 4.0019 _38.92 _,20.03 0 -0 0 -0 0 _0 -0 11 13A4oce 10D-m 4A5-2om 4A5-2om 4A5-20m 4A5-2omd ASS-2fm 13A 40cs 4A5-2om- 0.143 1.390 0.770 0.770 0.770 0.770 �0.590 0.143 -0.770 a a a a a a a -sr-4.00 _se 4.00 38.92 21.56 21.56 21.56 21.56 16.52 -21.56 2.19 22.46 46.95 46.95 46.95 22.78 16.82 2.19 -19.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ^--0 0 0 0 0 0 0 0 Vy `G 0 -0 -0--- -0-0--0 0 - 13A40cs 4AS2om 4A5-20m 4AS20m 11D0 22A-WI 0.143 0.770 0.770 0.770 0.390 =0.408 0.989 w w w w _w _ - 4.00 21.56 21.56 21.56 10.92 _1.59. 27.69 2.19 46.97 33.90 37.20 10.34 -1.37. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -140 0 0 0 0 C-.ifiX79-0md F E-88 �86 _120 0.00 88 0 0 0 _ 61 0AED excursion -6 Envelope loss/gain 140 114 12 a) Infiltration b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 Appliances/other 0 0 0 Subtotal (lines 6 to 13) 140 114 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 18Y .4 0 0 -140 0 0 0 0 -114 0 0 Atrrequired(cfm) I I I 01 0I _ Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. 2018-Deo1709:27:41 Aft RightSuite® Universal 201818.0.19 RSU08101 Page 10 ...ADocumentslWdghtsoft HVACIReals Residence.mp Cale =MJ8 Front Door faces: W Duct System Summary Job: +�- wrightsofte Y ry Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickealcs@aol.com For: Reals Residence XXX NW Dunn Road, Fort Pierce, FL 34983 External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.230 in/100ft 1400 cfm 218 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.230 in/100ft 1400 cfm Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath h 1872 72 39 0.273 6.0 Ox0 VIFX 53.3 130.0 st4 Bathe h 1870 72 30 0.230 6.0 OXO VIFx 67.7 150.0 st5 Badmom 2 C 2038 90 91 0.275 7.0 OX 0 VIFx 52.1 130.0 st4 Bedroom 3 h 3293 127 113 0.263 7.0 Ox 0 VIFx 60.2 130.0 st4 Closet h 801 31 12 0.235 4.0 Ox0 VIFx 62.7 150.0 st5 Closet h 97 4 3 0.241 4.0 Ox0 VIFx 57.4 150.0 sty Great Room C 3097 118 138 0.351 7.0 Ox 0 VIFx 32.6 110.0 st3 Great Room -A C 3096 118 138 0.362 7.0 Ox 0 VIFX 28.3 110.0 st3 Great Room-B C 3096 118 138 0.351 7.0 OXO VIFX 32.6 110.0 st3 Xltchen o 2625 36 117 0.460 6.0 Ox0 VIFx 18.8 90.0 st2 IGtchen-A c 2625 36 117 0.460 6.0 Ox0 VIFx 18.8 90.0 st2 Master Bath h 2240 86 43 0.446 6.0 Ox0 VIFx 22.0 90.0 st1 Master Bedroom h 3906 150 117 0.471 8.0 Ox0 VIFX 16.2 90.0 st1 Master Closet h 991 38 16 0.443 5.0 OXO VIFX 22.9 90.0 st1 Nook h 3682 142 98 0.416 7.0 Ox 0 VIFx 30.2 90.0 st2 Pantry h 400 15 7 0.427 4.0 Ox 0 VIFX 27.0 90.0 st2 Study C 3055 99 136 0.275 7.0 Ox0 VIFX 51.7 130.0 SO Toilet h 1188 46 16 0.419 5.0 Ox0 VIFx 29.4 90.0 st1 Utility C 653 6 29 0.469 4.0 Ox0 VIFx 16.7 90.0 SO Aj- wrightsoft, 2018-oeo-170927:42 C A- ....•� �.�.._.�, RighlSuiteO Universal 201818.0.19 RSU08101 Pagel RM ... r�Documents WWdghtsoft HVACIReals Residence.mp Cale=MJ8 Front Door faces: W Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st5 Peak AVF 106 45 0.230 398 7.0 0 x 0 VinlFlx st4 st4 Peak AVF 494 424 0.230 462 14.0 0 x 0 VinlFlx st3 st3 Peak AVF 846 839 0.230 606 16.0 0 x 0 VinlFlx st2 st2 Peak AVF 1075 1178 0.230 667 18.0 0 x 0 VinlFlx st1 Peak AVF 325 222 0.419 414 12.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (Cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mail Trunk rb1 Ox0 1400 1400 0 0 0 0 Ox 0 VIFx M�C '*' wrightso6fY Rig htSuite® Universal 201818.0.19 RSU08101 T/M�...r1DOCnrnents WWflghl50ft HVAC\Reals Residence.rup Cale =MJB Front Door faces: W 2018-Deo17 09:27:42 Page 2