Product Evaluation Report FILE COPY
TteIof- a313
1.0 Nail Strip/SnapLock Seam Roof Panel over 15132" Plywood
Florida Product Approval 4 21423.8
Florida Building Code 2017 6th ad
Per Rule 61G2D-3 Method: 1—D
Category: Roofing Subcategory: Metal Roofing Compliance Method:
Rule 61G20.3
HVH2
Product Manufacturer:
Sunlast Metal
2120 SW Poma Drive
Palm City, Florida 34990
Engineer Evaluator
Vane G. Marotta, P.E. FL reg N
82591
1915 NE WST. W107
Fort Lauderdale, FL 33308
954.776.8004
Validator:
Locke Bowden, P.E., FL a49704
9450 Alysbury Place
Montgomery, AL 36117
Diane G. Marotta, P.E.
FL reg p 82591
seal
Page 1 of 4
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2,1507.1.1, 1507.4.3, 1518.9,1523.6.5.2.4
Product Description: 24GA Panel,16" Nail Strip/snap lock mechanical attached
16" Coverage Width Roof panels 1.0" Rib height
Panel thru fastened; into 15/32" APA Plywood decking. Non-structural Application.
FOR USE IN HVHZ.
Material: 24GA Steel, Galvalume conforming to Florida Building Code 2017 Section 1507.4.3
56ksi yield strength min. Corrosion Resistance: Panel Materialshallcomply with Florida Building Code 2017, Section 1507.4.3
and Section 1517 for HVHZ
Fastener: #10 X 1" Pancake -Head wood fasteners or equivalent. 3/16" minimum penetration through support. Corrosion
Resistance: Per Florida Building Code 2017, Section 1506.6,1507.4.4
Sealant: Bostick Chem Calk 915 (Silyl modified polymer (SMP) apply 1/16" bead atop rear leg of male joint, adjacent to fasteners
continuously along entire length of panel.
15/32" APA plywood, plywood supports at maximum 2,V O.C. Design of plywood and plywood supports are outside the scope of
this evaluation. Must be designed in accordance w/ Florida Building Code 2017 and RAS 133.
TABLE A Safety factor of 2:1 included
Design Pressures
Field
Perimeter/Corner
Max Design Pressure
-84.25psf
-136.75psf
Fastener Spacing
12" o.c.
6" o.c.
Fastener Size
#10
#10
Insulation: Optional Rigid Insulation board, 3" max thickness compliant with FBC 2017 section 1508.2
Quality Assurance: In accordance with FBC 2017 and Rule # 61620-3: Keystone Certification, Inc. QUA 1824
Test References: Hurricane Test Laboratory (TST1527) 0412-0306-06 RA TAS 125-2003
Architectural Testing Inc (TST 1527) # 0412-1203-07 and 0412-0621-07 TAS 125-2003
Architectural Testing Inc. (T5T 1527) C6413.01-450-18 REV 1 TAS 125-2003
PRI Construction Material Technologies(TST5878) SFMS-002-02-01 R1 TAS 100-1995
PRI Construction Material Technologies(TST5878) AKZC-001-02-01/05 ASTM B 117-2002
PRI Construction Material Technologies(TST5878) AKZC-001-02-01/05 TAS 110-2000
AKZO Nobel Coatings, Inc. Lab Form ASTM G 153
Code Compliance: The product described herein demonstrated compliance with The Florida Building Code (FBC) 2017 Section
1504.3.2.,1523.6.5.2.4.1. The product evaluation is limited to compliance with the structural wind load requirements of the FBC
2017, as relates to Rule 61620-3.
Minimum Slope Range 2/12 Minimum Slope per Florida Building Code 2017, and in accordance with Manufacturers
recommendations.
Installation: Install per manufacturer's recommended details in compliance with FBC 2017 and RAS 133
Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2017, Chapter 1507 Chart 1507.1.1
Roof Panel Fire Classification: No classification.
Shear Diaphragm: values are outside the scope of this report.
Page 2 of 4
Design Procedure: Based on_the dimensions of the structure, applicable wind loads are determined using Chapter 16 of the
Florida Building Code 2017 -roof cladding wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. Design professional shall select the applicable erection details to reference in drawings for
correct fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be
compliant with Florida Building Code 2017 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading.
Required wind loads shall be determined per project per FBC 2017 and any rational analysis computation shall be prepared by a
licensed design professional.
Certificate of Independence: DianeG. Marotta,.P.E. does not have nor will acquire financial interest in. any company
manufacturing or distributing products under this evaluation. Diane G. Marotta, P.E. is not owned or operated or controlled by
any company manufacturing or distributing product under this report.
PRODUCT EVALUATION REPORT
Page 3 of 4
I
5uh/ast Meta/
Value Engineered Metal Roofing 7M
TABLE A #10 X V Pancake -Head wood fasteners or equivalent. 3/16" minimum penetration through support
Roof Areas Field Perimeters and Comers
Maximum Design Pressures -84.25psf -136.75 psf
Screw Spacing 12" O.C. 6" O.C.
INSTALLATION METHOD
DRAWINGS
TYPICAL ASSEMBLY PROFILE VIEW
16" Coverage
Striations Optional
TYPICAL ASSEMBLY ISOMETRIC VIEW
;-Bead of flosilk
Ghernfau* 915
.dh..'ne 11 -
Fash,nerSpadng
a:Zr.1. Table A
h
Page 4 of 4
Certificate of Authorization No. 29824
G " E E K- - — - _ 17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 6Te EDITION
Manufacturer:
TRI-BUILT Materials Group Issued July2, 2018
9050 Louisiana Street
Merrillville, IN 46410
55
FILE
L
www.tribuiltmate ri alsprou a.
conFI E COPY
Manufacturing Location:
Tuscaloosa, AL
1'� I21%&4—'31gb 1 _ D39 3
Quality Assurance:
UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Undedayments
CONCEALED FASTENERSORATTACHMENTS
Code Sections:
1504.3.1, 1507.1.1, 1523.1.1
ARETHE RESPONSIBILITY OFTHE
Properties:
Physical properties
CONTRACTOR OR RECORD
REFERENCES
Enti Report No. Standard Year
PRI Construction Materials Technologies (TST5878) MSA-044-02-01 ASTM D 1970 2015a
PRI Construction Materials Technologies (TST5878) MSA-047-02-01 ASTM D 1970 2015a
PRODUCT DESCRIPTION
Ice and Rain Stopper Ice and Rain Stopper is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.8-ft and has a
nominal thickness of 50 mils.
THESE PLANS AND ALL PROPOSED VJORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
ST. LUCIE COUNTY BUILDING
REVIEWED FOR COMPLIANCE,,
PLANg-A-96 PtiiMiT MUST BE KEPj�N JOB
SITE OR NO INSPECTION(S) WI E MADE
TBM18001 FL27483 Pace 1 of 3
This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
D TRI-BUILT MATERIALS GROUP
1-C Self -Adhering Underlayments
TECHNICAL. SERVICES,. LLB— ----- - - - - -
PRODUCT APPLICATION
Min. Roof Slope: 2:12 or in accordance in with the FBC
Application: All underlayments shall be installed in accordance with the FBC.
In the HVHZ, the underlayment shall be installed in accordance with Section 1518.3.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to
underlayment application. Prior to beginning installation, the underlayment shall be
unrolled and allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed
firmly into place to ensure complete contact with the deck. The underlayment shall
be installed with the roll length parallel to the eave, starting at the eave, and with
minimum 3" side laps and minimum 6" end laps staggered min. 6-ft.from preceding
course.
It is permissible to back nail the underlayment 12-inches on -center as needed (nails
shall be installed perpendicular to deck with the nail heads flush to the top surface of
the underlayment).
Min. Application Temperature: 40°F; Contact the manufacturer when installing at temperatures below the minimum
application temperature.
Allowable Roof Coverings: Ice and Rain Stopper is permitted to be used as prescribed in FBC Section 1507.1.1
for mechanically attached roofing coverings.
GENERAL LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
3) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
4) The space under the deck area shall be properly ventilated in accordance with the FBC requirements.
5) All side lap seams shall be installed to shed water from the deck.
6) The underlayment may be used as described in other current FBC product approval documents.
7) The underlayment shall not be left exposed for longer than 30 days.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads
determined for the roof assembly.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
TBM18001
FL27483
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report invalid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
D I-i �" .,TRI-BUILT MATERIALS GROUP
CREEK
Self -Adhering Underlayments
TECHNICAL SERVICES,-LLC— - - - - - - - - -
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
�\CENSF
No 74021
9 STATE OF
< O R \ 1D. I?. I N��;`
S/�NA� ����%
CERTIFICATION OF INDEPENDENCE
2018.07.02
09:07:50
_..-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT