SCOPE:
This NOA is being issued under the.applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and acceptedbyMiami-Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be.valid after the expiration date stated below. The 'Miami -Dade County Produci Control, Section,
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material:fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control. Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described -herein, and has been designed to comply with the Florida Building Code
including the High Velocity, Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polygtass,Polystick Underlayments
LABELING: Each unit shall bear a permanent label:with the manufacturer's, name or logo, city, state and`following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted. herein.
RENEWAL of this NOA shall be considered after a renewal.appiication has been filed and there has been no change
in the applicable building code negatively affecting the performance of this -product.
TERMINATION of this NOA will occurafter the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any. product,
for sales, advertising or any other purposes,shall automatically terminate this NOA. Failure to comply with anysection
of this NOA shall be cause for terminatiomand removal, of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County; Florida, -and followed'
by the expiration date may be displayed in advertising literature. If any portion of the NOA, is displayed, then
it shalt be done'in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the jobsite at the request of theBuilding Official.
This NOA renews and revises NOANo.15-0410.04 and consists of pages 1 through S.
The submitted documentation was reviewed by Freddy Seminol
NOA No.: 17-0614.22
MAMCOUNTY Expiration Date: 09/13/21
N1111111l ` ' Approval Date: 07/06/17
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
__ PRODUCTS DESCRIPTION:
Test Product
.Product Dimensions. Snecification Descrinton
Polystick IR-Xe '65' x T3?1e" ASTM D 1970 A fine granular/sand top "surface self -adhering, APP'
Manufacturing Or 65' x3' polymer modified, fiberglass reinforced; bituminous
Location #1 &'#2 60 mils thick sheet material for use as an uhderlayrnegt in sloped roof
assemblies. Designed as an ice & rain shield.
Polystick"Dual Pro
61' x T3 '/s"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM'D,1970 reinforced waterproofing membrane. Designed as a
Location #2
metal roofing and roof tile underlayment.
Polystick Tile Pro
61' x-3'3 '/s"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
Manufacturing
60 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Location#2
roofing and roof tile underlayment.
Polystick TU Max
65'8" x3'3-3/8"
TAS 103 and A rubberized -asphalt self -adhering, polyester reinforced
Manufacturing;
60 mils thick
ASTM' D 1970 waterproofing membrane. Designed as a a roof the
Location #1 
underlayment.
Polystick TUP
32' 10" x 3'3='/s"
TAS 103 and A rubberized asphalt waterproofing membrane, glass -
Manufacturing
130 mils thick
ASTM' D 1970 fiber/polyester reinforced, with a granular surface
Location #2
designed for use as a tile roof underlayment.
Polystick TU Plus
65' x 31'/s"
TAS' 103 and A rubberized asphalt self adhering, glass-fiber/polyester
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as it metal
Manufacturing
roofing and roof tile underlayment.
Location #1 & #2
Polystick MTS
, 08" x 3'3= /a''
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane,: glass fiber reinforced with'polyolefinic:film.
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate,tles'and shingle: underlayment.
Polystick MTS-Plus
65'8" x3'3-;/s'
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefifiic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tles:and shingle underlayment.
Elastoflex S6 G 32' 10" x 313-W TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2 use in roof tile underlayment systems.
MnnF�oE' NO : 14.22
catmTExpiration Date: 019113iL1miiiiiiiiiiiiiaaaav
Approval Date:-07/06/17
Paget of '9
r
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven; FL
EVIDENCE SUBMITTED
Test Aeencv
Test Identifier
Test Name/Report
Date
Trinity ERD
PI0870.09.08-R1
TAS 103
12/04/08
P10870.04.69
TAS 103/ASTM D4798 &G155
04/13/09
.M360.06.10
ASTM D1970
07/01/10
P33370iO3a1
TAS 103
03/,02/11
P33370.04.11
ASTMD 1623
04/26/11
P36900.09.11
TAS 103/ASTM D4798 & G155
09/01/11
P37300.10.11
TAS 140/ASTM D4798 & D1970
10/19/11
P40396M'.12-2
ASTM D 1623
08/67/11
P37590.07.13-1
ASTM D6164
07/02/13
P45270.05.14
TAS 103, TAS 110 & ASTM D1623
05/12/14
1`46520.1014
ASTM D1623
10/03/14•
1`44360.10.14
TAS 103 & TAS 110
10107114.
P43290:10.14
ASTM D 1970 & TAS 110.
10/17/14
PLYG-SC10130.M16-3
TAS 103 & TAS 110
06127/16
PLY6-10J30.06.16-1
ASTM D1970 &TAS 110
06/27/16
PRIAsp halt Technologies
PUSA-035=02-01
TAS 103
09/29/.06
PUSA-055-02.02
TAS 103
12/10/07
PUSA-089702=01.
TAS 103/ASTM D4798 & G 155
071,06/09
Momentum Technologies; Inc.
JX2047A
TAS 103/ASTM D4798 & GI55
04/01/08
RX14E8A
TAS 103/ASTM D4798 & GIS5
11/09/09
DX23D8B
TAS 103/ASTM D4798 & G155
02/18/10
DX23D8A
TAS 103/ASTM D4798 & G155
02/18/10
LABELING:
1. •AIl membranes or packaging shall -bear the imprint or identifiable marking of the manufacturer's name or logo, city
and -state -of manufacturing facility and the.following statement: "Miami -Dade County Product•Controi Approved"
6fthe Miami -Dade County Product Control Seal as shown below.
MIAMWADECOLi -
$UILDIN6.PER1YIPr. REQUIREMENTS:
Application for building petmit..s,Fiall be accompanied by dopies of the following:
1. This Notice of.Acceptance.
2. Any other documents required by -the Building Official or applicable building code in order to properly evaluate the
installation of thismaterials.
NOA No:: 17-6614.22
MIAMWAIN CAUM[Y� Expiration Date: 09/13/21.
Approval Date: 07106/17
Page 3 of. 8
INSTALLATIONTROCEDURES:
Deck Type 1- Wood, non -insulated
Deck Description: 'Min. 19132" plywood or wood plank
System Typet(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a.minimum 4" head lap. (for
base sheet only)
Membrane: Polystick'IR-Xe, Polysti&Dual Pro,,Polystick Tile Pro, PoIystickTU Must Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered.
Surfacing: See General Limitations.Below.
Deck Type 1: Wood; non -insulated,
Deck Description: Min. 19/32" plywood.or wood plank
System TypeE(2): Anchor sheet mechanically fastened to:deck, membrane adhered
AnchorMase Sheet: One or.more plies of ASTM D 226'Type ll:or ASTM D 2626..
Fastening: Per FBC 1518.2 & 1518.4 Nails -and tin caps 12" grid, 6" o.c. at a minimum 4 head lap. (for
base sheet only)
Membrane: Elastoilea S6 G; hot asphalt applied
Surfacing: See General Limitations Below.
Deck Typed: Wood, non -insulated
Deck Description: Min. l9/32"'plywood or wood plank
System Type E(3): Base sheet mechanica►ly fastened to deck, subsequent cap membrane self -adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4,"head lap: (for,
base sheet only)
Ply Sheet: Polystick MTS Plus; self-adheredwith minimum 3" horizontal, laps and minimum 6"
vertical laps.
Membrane: Polystiek.TU Plus, self -adhered:
Surfacing: See General Limitations Below.
NOA No.: 17-0614:22
�MIAMWADEeotaerr + Expiration Dater 09/1321
Approval Date:07/06t17
Page 4 of li
INSTAL"TION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck: panels, and
sweep the,deck thoroughly to re move any dust and debris prior to application.
2. Place the•underlayment over:metal drip edge in accordance with'RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove -the release -film as the membrane -is applied. All side -laps shall be -a minimum of 3"and-end laps shall
be a minimum of 6"'. Roll the membrane •into place,after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable, building code.
4. When applying the membrane in the valley, start at the low pointandwork to the high point,-rollingthe
membrane from the center outward in both directions.
3. For ridge applications, center.the membrane and roll from the center outwardn,both directions.
6." Roll or broom the entire membrane surface so as to havefidl contact with the surface, giving special attention
to,lap.areas.
7. Flash vent,pipes stacks, chimneys and penetrations in compliance with Roof Assembly currentProductControl
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The:flashing tape shall be
pressed _in place and formed around the protrusion to ensure a tight.fit. A second layer of Polystick shall be
appliednVer the underlayment.
GENERAL LImiTATIONS:
1. Fire classification is: not part of this acceptance.
2. Polystick Dual Pr`o,.PolystickTile Pro; PolystickTU Plus, Polystick NITS andPolystick MTS Plus may be
used in asphaltic shingles, woodshakes,and shingles;.non�structural metallroofing; roof tile systems -and quarry
slate roof assemblies.
Polystick'TU P may be used in all the previous assemblies listed except metal roofing.
Polystick'IR.Xe may be used in all the,previous assemblies listed except meta l.roofing_androof ti_le systems.
Polystick TU Max may be used in non -Structural metal.roofingand roof tile systems.
Elastoflex' S6 G may be used; in:rooftile systems ohly:,
3.. peck"requirements shall be in compliance with,applicable building code.
4. Polystick dR-Xe,,Polystick'Rual Pro, Polystick Tile P.ro, Polvstick TU Mai, Polystick•TU P, Polystick TA
Pius, Polystick°MTS, and Polystick MTS Plus shall'bc.applied wa smooth; clean and.dry surface: -The deck
shall be'free of, iireaularities..
5: Polystick IR-Xe, Polystick Dual Pro; PolystiekTiieTro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick,MTS and Polystick MTS,Plus shall not be adltereddirectlyover a=pre-existing; roof membrane
as'a recover _system.
6. PolysticklR-Xe, Polystick Dual Pro; Polystick Tile Pro,,Polystick TU Max; Polystick TU P, Polystick TU,
Pius, Polystick'MTS and'Polystiek MTS:Plus shall not be left exposed -as a temporary roof for longer than the
amount,of"days listed in the table below -after application. Polyglass reserves the righko revise or:alter product
exposuretimeIs;,not,to exceed the preceeding maximum time limitations.
- EitiosureLimitations
Tta s -
-
MTS I
IR-Xe
I Elastoilea
S6G_ _
TU
,Plus
T'tJP`
Tito Pro
Dual Pro
TU Mai
'MTS'Plus
Winter Raven, FL.
18o
_ 9Q . _
- t80
180'
180
180 -
180 .
180
180
Hazelton PA
NIA s
90..
1, NIA .'
180
'NIA
I N/A
I N/A
1 180,
N/A
7.- All products listed herein shall have,a quality assurance audit in accordance withtheFlorida, Buildfng'Code,and
NOA No.: 17-0614.22
Etta wane Expiratiou.Date: 0911312t
Approval Date: 07/06/17
Pages OU 8
Rule 61G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the.aMchment resistance of roof,tiles shall be as set forth in the roof tile
manufacturer's -Notice ofAeceptance.
Polystick Tile Pro,_Polystick TU Max, Polystick TU Plus or:Elastoflex S6 G may be used in both adhesive
set and"mechanicallyfastened,rooftile applications.
.Polystick Dual Proas limited, to°mechanically fastened roof the applications.
Polystiek NITS andPolystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Sectors 9.
Polystick TU P may be used in mechanically fastened -roof the applications with the exception of mortar set the
applications.
9. When,loading roof tiles on roof the underlayment-for (direct to-deek)_tile assemblies, the maximum roof slope
shall be as follows: (SeeTableBelow)
Tile
Polystick
Elastofles
- Potystick TU P1us,
Polystick
Polystick
System (E3)
Profile
MTS
S6 G
TU'Pi.Tile'Pso,
TU Max
MTS Plus
MTS Pius with '
Dual Pro
TU Plus-
FlatTile
Prohibited,
'4't12
6:12 ,
6:12
512'
6:12'
_
withoutbattens_.
Profiled
Prohibited
4:12
6:12,
6:12
4:12
5:12
Tile
without battens
The above slope limitatonsrgan.be exceeded'only by using battens in accordance with the .Approved Tile System
Notice of Acceptance and applicable Florida BL lding Code requirements. When battens are required they;shall.
be utilizedduring16adingAa d.insfallationoftiles.
10. Care should betaken during.the loading procedure to keep foot traffic to aminimum�and to Avoid hopping of
the directly; on the vnderlayment. Refer to'Polyglass. Tile loading detail below for loading procedare -.twat les
laid'perpendicular to slope followed by a maximum four the stack parallel to the slope, for a total of 6 tiles for
all underlaymems>6xcept Polystck MTS which shall be loaded onto battens.
NOA No.: 17-0614.22
MIAMI, D COUNTY Expiratiow-Dafe: 09(13al
- Approval Date: 07/06/17
,Sage 6 of `8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products, Polystick IR Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TV P, Polystick TU Pius, Polystick MTS, Polystick MTS. Plus or Elastoflex S6 G may
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pi•o„Polystick TU Max, Polystick•TIJ, P, Polystick TU Plus, Polystick MTS, Polystick MTS
- -Plus or Elastoflex S6 G as a component part of an assembly,in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystiek TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS,Plus or Elastoflex S6.G are _not listed; a iequest may be made to the
Authority Having Jurisdiction (AHJ) or the Miami' -Dade County Product Control Section for approval provided
that appropriate documentation is,provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES'FOR POLYSTICK MEMBRANES,
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING"LIMITATIONS OF SPECIFIC APPLICATIONS.
FOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMFNTS.AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local.building codes prior to direct deck installation to ensure this is acceptable.
Please also ieferto applicable Product Data Sheets of the corresponding products.
2. All rolls, With, the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, l t gauge ring shank type, applied with a minimum I W metal disk as
required in Miami -Bade County or simplex type nail as otherwise allowable in other regions, ata minimum rate.
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area:para clavar" on
the face of membrane, with the above stated.nails and/or disks. The head lap membrane is to cover the area tieing'
back -nailed. (Please refer to applicable local•building codes prior to installation.)
3. All sear, lap seams (selvage laps) must be rolled, with a hand roller to-ensurefull,contact.
4. All fabric over fabric; and granule over granule end laps; shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cemenf,.Polyglass PG500 MB Flashing Cement, applied in between
the application ofthe-lap. The use of mastic betweemthe laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations'#9`and 610,
6. Battens and/or Counter, -hatters, as required by the the manufacturers NOA, must be used on at l.projects for
pitchislopes of T712" or greater. It.is suggested that on pitch/slopes in excess of 6'/dY12", precautions should be:
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
S.. Polystick membranes° may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair.of Polystick-membranes is to be accomplished by, applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet(DryCement, Polyglass PG500MB Flashing Cement to the area in need of repair, followed by a -patch of the
Polystick material oflike kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such away so
that -water will run parallel to or over the top ofall laps of the patch.
NOA No.: 17-0614.12
t�nMH)PD COUNTY Expiration Date: ,09l13/21
Approval Date: 07/06117
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs fora weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small,area-s of the roof. Broomingmaybe used.where slope prohibits rolling.
11. All,appirgvedsobstrates should be dry, clean and properlypre ed,be par fore any application of Polystick
membranes commences. An approved,slubst,rate technical bulletin can"be furnished uponxequest. Iris
recommended to refer to-applicablebuilding codes,prior.to installation to verify, acceptable substrates.
12. The Plo,lygl4ss Miami-DNotice
ad1e 11 - - ofAcceptance, , (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by -,calling 1, (800) 8944563,
13. Questions in regardsto the application of Polygl*.Drciducts should be directed to durleclihical' Services
Depaitmenvai 1 (800) 894456j: — 11 1 -
14. Polyglass recommends that applicators, follow good roofing practices and I applicable .procedures ,as outlined by
the NatidriAlRoofiiie7Cotitradf6is,Ass&ciiition(NMCA)-
LOCAL SUILDING.CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
MAV-,SUPERSEDEPO -SSREQIVIREMENqS-AND RECOMMENDATI . ONS,
_�VGIA
END OF THIS ACCEPTANCE
NOA No.: 17-661411
Expir4flon Date: 09/113/21
Approval Date: 07106/17