Loading...
HomeMy WebLinkAboutEVALUATIO0N REPORT - ROOFING14o F�F�Fo EVALUATION REPORT OF q✓ N 222919 METAL SALES MANUFACTURING CORPORATION hkr `26 GA. IMAGE II PANEL' st �OCe a sn� FILE COPY FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 11560.4-R3�RP1NE® ROOFING ESY METAL ROOFING %tLU6i0"tltifdy CONCEALED FASTENERS ORATTACHMENTS ARE THE RESPONSIBIUJTYOFTHE CONTRACTOR OR RECORD Prepared For: Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 �p Telephone: (502) 855-4300�66 V Yu\ Fax: (502) 8554200���` ST. LUCIE COUNTY BUILDING D SION REVIEWED FOR COMRWUANCE zy /% wIF THESE FLANS AND ALL PROPOSED WORK DATE ' EREVIEV I ARE SUBJECT TO ANY CORRECTIONS PLANS A REQUIRED BY FIELD INSPECTORS THAT prepared By: SITE OR NO COMPLY NECESSARY IITH ALL APPLICABI ORDER TO g Bala Sockalin a Ph.D. P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) %% % OCKd �rso, Report No. C2181-4 Date: 9.8.2017 %� p S </N ie.. No 62240 e 1. 0�. STATE OFV: 0 R =i 2-0 �� FL 11560.4-R3 C2181-4 - - 9:8-2017 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Image lI Panel Description: Max. 16" wide coverage with 1" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 15/32" thick plywood or min. '/4" thick wood plank (min SG of 0.42) for new and existing constructions. Designed and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 84.25 psf @ fastener spacing of 24" o.c. (Factor of Safety = 2) Fastener Pattern: #10-12 pancake head screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum of/4". Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. FL 11560.4-R3 C2181-4 Page 3 of 3 Supporting Documents: TAS 125 Test Reports Hurricane Test Laboratory, LLC HTL Report #: 0103-0714-09, Reporting Date 9/1/09 SEE DETAIL 1 ROOF PANED MIN. 2X_ WOOD RAFTER/JOIST/ TRUSS AT MAX. 24' O.C. MIN 26 GA. NEW UNDERLAYMENT EXISTING SHINGLES (OPTIONAL) EXISTING UNDERLAYMENT (OPTIONAL) NEW UNDERLAYMENT EXISTING SHINGLES (OPTIONAL) EXISTING UNDERLAYMENT (OPTIONAL) MAX. 16" MINIMUM ATTACHMENT: Ed x 2.5' LONG RING SHANK NAIL OR QB x 2' LONG WOOD SCREWS SPACED ® 6' O.C. IN THE FIELD & 0 4' O.C. AT PLYWOOD EDGES TYPICAL PANEL INSTALLATION X-SECTION #10 PANCAKE SCREWS (MIN.) ALLOWABLE UPLIFF PRESSURE FASTENER PRESSURE SPACING (PSF) (IN) 24 84,25 PLYWOOD GENERAL NOTES. 1 HASBEEN DESIGNED IN ACCORDANCE WITH THE .I THICK (MIN.) DETAIL COOEPANEL FLORIDABUILDINGROOF 2. ROOF PANELS ARE SHALL BE MIN. 26 GA. MAX, EFFECTIVE COVERING WIDTH OF PANEL = 16'. 7. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND. LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE, IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPUCATION AND ARE THE RESPONSIBILITY OF OTHERS. or v