HomeMy WebLinkAboutGENERATOR RISER DIAGRAMABBREVIATIONS AC ALTERNATING CURRENT , - MDP MAIN DISTRIBUTION PANELBOARD --A/C-_ AIR CONDITIONING - MTS-- -MANUAL-TRANSFER SWITCH --' AFG ABOVE FINISHED GRADE MLO MAIN LUGS ONLY AL ALUMINUM NEC NATIONAL ELECTRICAL CODE AHU AIR HANDUNG UNIT NTS NOT TO SCALE ATS AUTOMATIC TRANSFER SWITCH NEMA NATIONAL ELECTRICAL MANUFACTURERS AMP AMPERE ASSOCIATION AFCI ARC FAULT CIRCUIT INTERRUPTER NFPA NATIONAL FIRE PROTECTION ASSOCIATION ANSI AMERICAN NATIONAL STANDARDS INSTITUTE NON -SE NON SERVICE ENTRANCE RATED C CONDUIT PLCS PLACES (QUANTITY) CU COPPER CONDUCTOR PNL PANEL COVB CRYOFVEROBEACH PVC POLYVINYL CHLORIDE CONDUIT DC DIRECTCURRENT RMC RIGID METAL CONDUIT DISC DISCONNECT RTU ROOF TOP UNIT EXIST EXISTING SE SERVICE ENTRANCE RATED FPL FLORIDA POWER S LIGHT TYP TYPICAL G GROUND TEMP TEMPORARY GFCI GROUND FAULT CIRCUIT INTERRUPTER US UNDERGROUND IRC INDIANRIVERCOUNTY UL UNDERWRITERS LABORATORY KVA KILOVOLTAMPERE LON UNLESS OTHERWISE NOTED KW KILOWATT V VOLT MC METAL CI -AD CABLE VA VOLTAMPERE MCB MAIN CIRCUIT BREAKER W WATT MCC MOTOR CONTROL CENTER XFMR TRANSFORMER SCOPE OF WORK: • INSTALL TWO NEW200AMP, 1-PHASE, NEMA3R DISCONNECTS LEFT OFTHE EXISTING METER CAN. • INSTALL NEW B'k6%t5°LONG, NEMA 3R GUTTER ABOVE NEW DISCONNECTS AND EXISTING METER CAN. • INSTALL NEW 4410 SER ALUMINUM CABLE FROM EACH DISCONNECT TO THE NEW 200AMP NON -SE RATED ATSS LOCATED INSIDE GARAGE • INSTALL NEW44M SER ALUMINUM CABLE FROM EACH NEW ATS TO EACH EXISTING HOUSE PANEL REMOVE EXISTING PANEL FEEDERS AND CONDUIT BACK TO METER CAN. INSTALL TV40200AMP NON -SE RATED ATS'S INSIDE GARAGE. INSTALL NEW 69G906°LONG, NEMA 1 GUTTER ABOVE NEW ATS5. • INSTALL COLD WATER BOND FROM ATS TO NEAREST CU WATER PIPING. • FORM AND POUR CONCRETE PAD FOR GENERATOR • PROVIDE AND INSTALL(1) 38kW KOHLER LP GAS GENERATOR. • PROVIDE AND INSTALL CONDUIT AND CONDUCTORS FROM ATS TO GENERATOR. • PROVIDE (3) LOAD SHED DEVICES PER SRING DATA THIS SHEET. • GENERATOR LP GAS CONNECTION BY OTHERS UNDER A SEPARATE PERMIT. • NO NEW BRANCH CIRCUIT LOADS SHALL BE ADDED TO HOUSE PANEL UNDER THIS SCOPE OF WORK ELECTRICAL LEGEND: (SOME SYMBOLS SHOWN MAY NOT PERTAIN TO THIS PROJECT) FR 2612E SURFACE MOUNT 120204V, 10, 34VIRE PANELSOARD l r j aOM an� NEwnnnxo NOPLFUSED DISI -�- FLUSH MOUNT 1202MV, 10, 3WIRE PANELSOARD -'�- NON MSEP -L;"[- SURFACE MOUNT 277/48OV, 30,4-WIRE PANELSOARD --Q- FLUSH MOUNT 2T//"W. 30, bWIRE PANELSOARD UTIUTY METER CAN OR METERMAIN COMBO UNIT �- SURFACE MOUNT AUTOMATIC TRANSFER SWITCH POINTOFNEWCONNECTION CU GROUND RODS 1� FRMES1 aR Ne.MlNa FUSEDDISCONNECT -ILL'_ NSE 3NE GENERATOR AND GENERATOR PAD GAS STORAGE TANK ® NATURAL GAS METER GENERAL NOTES: • THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICE ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTIUTY POWER COMPANY. • THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE STH EDITION(2017), LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE THIRTEENTH EDITION NFPA 70 (2014), • ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. • THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SECURELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NEC 110.26. • ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGI TESTING LABORATORY. • GROUNDING PER NEC ARTICLE 250. • STANDBY SYSTEM INSTALLATION PER NEC ARTICLE 702, AND MANUFACTURER INSTALLATION INSTRUCTIONS. LOAD MANAGEMENT RCM -LOAD SHED LOAD MANAGEMENT TECHNOLOGY ALLOWS THE LOAD CONTROL MODULE TO MONITOR GENERATOR PERFORMANCE AND ONLY SHED LOADS WHEN ABSOLUTELY NECESSARY BY MONITORING GENERATOR CURRENT AND FREQUENCY. BY ONLY SHEDDING THE NONESSENTIAL CIRCUITS, THE ESSENTIAL CIRCUITS ARE ALWAYS POWERED. LOADS ARE SHED THROUGH INTERRUPTION OF INDIVIDUAL CONTROL CIRCUITS (AHU/AC) AND POWER CIRCUITS (RANGE AND WATER HEATER). N7SGENERATOR ADDITION RISER DIAGRAM GENERAL NOTES: -1. UGHT LINE WORK REPRESENTS EXISTING TOREMAIN. - CT 2. DARK AND RED LINE WORK REPRESENT NEW EQUIPMENT, CONDUIT, AND WIRE CONPIETE ELECTRIC INC. - 537SEBA3TIANBLVD. KOHLER. SEBASI160533 cm) B 32�e GENERATORS Sizing Report 11med Noftmd Vde 240 Gemmtm Fuel Croke ROPane Sang Nethod(NEC 220) PMN (Pert In re4dred W wte d ft lmpeeremillm, Bode v dfar wrote ham? Ge Landg&Re Nam 1�(ENO Saame Fad" Being Camel (&•2) 3950 11s5 3ma0� C� no, inns) I4trJun Cln A 2 3 ImmOryC i6 1 1s Managed Eetlme Ne Pwa Fi Inmoa Appli.&mO Lnad.S LIMO ImnP9) 2IOV Lad lFYll Ory¢r 5.5 X SS Mivmram 13 13 Rarge-Own MTop BS X &5 CmkTap 3.0 X 3.0 PodH . X as X 0.0 WNef Heater 6.0 X 5.0 Water Heater 5.0 X 5.0 Wafer Hmtm 5.0 X 5.0 Hdn (w m 6.0 X &0 Oi50x-asler 1s 1s Reldgerelm 02 04 d50wflslum Is iS Rehgaalm o.B as R*Mealm 0.8 as Pad Pump 2.0 2.0 Well Pump 1.5 1s &M Pump 0.5 as Weg Par, 1.5 Is M1vgarl 00 24 X 5H MmegW 65m Narepelo AF ¢mNMtlm&(aoGnp Leffiv (IrW) (e ) mV LmdIFWI 5.0l um x 5.0 a 0.9 za Tmunt X 2.0 X 0.0 nal of 0.0 9 X 1.4 Man apd EaOmated Nammliale Hp &Heat Pumye finds IWO (errya) MV Lindw MaNg elmnelrtll X OA 40 X 0.0 M1eaSy WemeW e2 X 0.0 30 X 0.0 ENInved Actual uwlzed Trensient Reaalmment (MA) (LRA) (UM) lagem Motor's SlaiangAmps lLA.1) .0 50 M oa NEC Summary NECLpM (M) Re9wed GenaWU ht,&Rempm'm 16A R-in-PlainAppS &Worn 55s eamalpOGarm w.ft 723 34.9 Caosne 1A 1.4 Hea4g(wldOmeMfa ma) 0 0 Larger W HeWeg& CooOg 1.4 1.4 3akg0emdonreadmmm WNECANde220,PMN 38.3 Demlkg 0 R MlNmum elze p..W1 Mr NVor a ,leautremenm 7 BTUbad.,q ed 483840 38 kW Kohler Generator Recommended (Mq- z n U K N Viz" LU 1L 4 Lu m Q Z r`LILI ILIyaE n EL M m 2mLU 0 fn U ZE LJ 'D J V� Up U w El 1 ',^01/00/2010 1 OF 2 HANGAR ABOVE NOT SHOWN FOR CLARITY F (NEW) 941D SER CABLES NEWATS'S. NEW GUTTER ABOVE ' OT SHOWN FOR CLARITY SINGLE FAMILY RESIDENCE 19604 KITTY HAWK CT. FORT ST. LUCIE, FL 3491 KITTY HAVVK CT. 3-4)' (NEW) GENERATOR FEEDER AND CONTROLCABLESTHROUGH ATTIC TO GENERATOR (NEW) GENERATOR AND PAD N X X GENERATOR SITE PLAN w E IS 3-5 X DRILL lw DEEPER THAN ANCHOR � EMBEDMENT NOTE. THE USE OF A CARBIDE DRILL BIT CONFORMING TO ANSI STANDARD B212.15 IS RECOMMENDED. TOP VIEW i FVMIN zi �-440-�-T LEFT ELEVATION FRONT ELEVATION N.T.S. GENERATOR PAD DETAIL ---------- E2 20F2 SCALE: I- - 20'-0•