HomeMy WebLinkAbout2525 JET CENTER PAPERWORKBUREAU OF FIRE
P.O. BOX 3030 TELEPHONE (561)-462-2312
FT. PIERCE FL. 34948-3030 FAX NO. (561)-462-2323
2400 RHODE ISLAND AVE.
FT. PIERCE FL. 34950
PLAN REVIEW
JURISDICTION: St. Jucie County
OCCUPANCY: St. Lucie Speedway
ADDRESS: 2525 Center Rd. Fort Pierce, FI.
CONTRACTOR:Vatale Mangasniello
ARCHITECT/ENGINEER: Robert Machen
BUILDING OWNER: Frank Dimaria
OCCUPANCY TYPE: Business
GROSS SQ FT: 240 sq ft.
OCCUPANT LOAD: 3
CONSTRUCTION TYPE:(NFPA-220) Type: V (000)
F.P.B.
BUILDING DEPT. 98010208
NO. OF STORIES: Two
PHONE NO: 394-6647
PHONE NO: 337-4615
REVIEW DATE: 1-30-98
AUTOMATIC SP'KLRS: No
NET SQ FT:
BASED ON: 100 sq ft. PIP.
SBCCI: Type: VI- unprotected
New Construction: Automatic spklr: Contractor:
Tenant Improvement: Fire Narrn: Contractor:
Shell Only: Fixed Fire suppression: Contractor:
Addition: Hood & Duct System: Contractor:
Renovation: Fuel Storage: Contractor:
1. All revisions must be in compliance before the final inspection.
2. The Fire Marshal requires 24 hr. notice on all inspections.
3. The building departments schedule all final inspections by the Fire Marshal.
Required Revisions:
1. The stair tread shall be a minimum of 11 inches measured from nosing to
nosing.
2. The guard rail shall be a minimum of 42 inches from the finished floor of
the landing.
3. Provide a 2A-1013C rated fire extinguisher.
Reviewed By: 00rDate: January 30, 1998
John K. Hayde
•
RR
ST. L-UCIE COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
2300 VIRGINIA AVENUE, ROOM 201
FT. PIERCE, FL. 34982-5552
DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE
This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all
applications for building "permit involving the construction of new residence (single or muh'rfamity), residential addition. any accessory
structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided
that no structural walls, columns or other similar component is being effected) and certain other minor building permits. For further
assistance, please Contact the Building inspection Office at 462-1553 or 462-2172.
CERTIFICATION STATEMENT:
I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS
HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OFTHE BUILDING CODES
CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL
ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND
FORCES SPECIFIED BY CURRENT CODE PROVISIONS.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (Please Bieck or complete the appropriate box)
1 BUILDING CODE EDITION USED (YEM) % SBCCI ASCE 7-98 OTHER (SPECIFY)
2. BUILDING DESIGN IS (CW.cK oto ENCLOSED PARTIALLY ENCLOSED OPEN BUILDING
3, BUILDING HEIGHT: G Z S p{iC7 FT 4. WND SPEED USED IN BUILDING DESIGN: /v D MPH
5.
WIND EXPOSURE CLASSIFICATION (no-'r32 To ExPpark7E TAarEs IN mm1XNG DOOE IDENMED IN LINE 01):
1'6Y/ 5 ice`%
g.
AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE
75 PSF
7.
3 S,
PEAK WIND VELOCITY PRESSURE ON EXIMOR FACES OF STRUCTURE
PSF
6.
IMPORTANCEIUSE FACTOR (oi rAiN FRom jKmLJING coce);
9.
LOADS: FLOOR PSF ROOFIDEAD; 7 PSF
ROOFAJVE: 3v PSF
�0.
WERE SHEAR WALLS CONSIDERED FOR STRUCTURE (CfEcK OmE) YES NO
If NO, why? (attach
explanation)
f 1,
, IS A CONTINUOUS LOAD PATH PROVIDED (cnEcK ONE) YES v NO
if NO, why? (attach
explanation)
12.
ARE COMPONENT AND CLADDING DETAILS PROVIDED (CFEcK Otq YES _ NO_
If NO, wiry? (attach
f3•
MINIMUM SOIL BEARING PRESSURE: SGy PSF,
i AS
WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION
INCLUDED WITH' THIS
CERTIFICATION IS T/�RUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND BELIEF. Zl�+15
NAME: 1�/%y71i(CjQ%2P/✓1/(/a/
CERTIFICATION NO:
RESIGN
FIRM: PATE
•
•. [SEAL HERE
_ .:_.. CnmavO
;0
ST. LUCIE COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
• 2300 VIRGINIA AVENUE, ROOM 201
• F/ FT. PIERCE, FL. 34982-5652
-- 407-462-4553 — - - --
DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE
This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all
applications for building permit involving the construction of new residence (single or mulli-famiry), residential addition, any accessory
structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided
that no structural walls, columns or other similar comfionenl is being effected) and certain other minor building permits. For further
assistance, please contact the Building Inspection Office at 462-1553 or 462-2172. _
PROJECT NAh1E
S-f.' Lx,cr E 5 ��¢ua,< g Ld *1- Z
_ _ ... ........,...,..... .... :,,.
STREET ADDRESS
�p s2 S L� E-µ>-T-u
....,...,
PR NUM9ER
T / E/dGt- E40-1
PERMIT NUMBER
OCCP. TYPE
CST. TYPE
CERTIFICATI2N STATEMENT:
I CERTIFY THAT, TO THE BEST OF MY KNOWLEDGE AND BELIEF, THESE PLANS AND SPECIFICATIONS
HAVE BEEN DESIGNED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OFTHE BUILDING CODES
CURRENTLY ADOPTED AND ENFORCED BY ST. LUCIE COUNTY. I ALSO CERTIFY THAT STRUCTURAL
ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND
FORCES SPECIFIED BY CURRENT CODE PROVISIONS.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (plea,, diedc or complete the app oPilate box)
t BUILDING CODE EDITION USED (rTaR) � SBCCI ASCE 7-98 OTHER (SPECIFY)
2. BUILDING DESIGN IS (cneCK ON_ry ENCLOSED PARTIALLY ENCLOSED OPEN BUILDING
3. BUILDING HEIGHT: G Z S AfC, Ff 4. W)ND SPEED USED IN BUILDING DESIGN: /r (7 MPH
5. WIND EXPOSURE CLASSIFICATION wErr=-R TU eCP 5 IE TABLES W ER"NG CODES IDr1mFIED IN UNE 01): 1 e'll S
e. AVERAGE WIND VELOCITY PRESSURE ON EXTERIOR FACES OF STRUCTURE 75 PSF
7- PEAK WIND VELOCITY PRESSURE ON EXTERIOR FACES OF 5TRUciURE: --11 S_ PSF
IMPORTANCE/USE FACTOR (OBTAIN FROM bUILI NG COW:
LOADS: FLOOR PSF ROOFIDEAD: / % PSF
WERE SHEAR WALLS CONSIDERED FOR STRUCTURE (uEax oNn YES
explanation)
IS A CONTINUOUS LOAD PATH PROVIDED (ct!EcK otr8)
explanation)
ARE COMPONENT AND CLADDING DETAILS PROVIDED tc+EcK oNE)
explanation)
13. MINIMUM SOIL BEARING PRESSURE G SU"1) PSF
ROOFA.IVE: 3 J PSF
NO _ If NO, why, (alladi
G/
YES NO
YES _ NO_
AS WITNESSED BY MY SEAL, I HEREBY CERTIFY THAT THE INFORMATION
CERTIFICATION IS TRUE AND CORRECT, TO THE BEST OF MY KNOWLEDGE AND
NAME: - IV,4-t-72,reGQ IjQ}2�>/✓Vr/I CERTIFICATION NO: i 6 � 3S
DESIGN FIRM:
DATE:
H NO, why? (attach
if NO, whyl (attach
DNrWI'Ti:135fIIH15� 1
AT
------------- —