Loading...
HomeMy WebLinkAboutREVISIONS - BUILDING PERMITIN rat,4,j OFFICE USE ONLY: DATE FILED: 1 �3 REVISION FEE: 1 S a d LOCATION/SITE ADDRESS: 4795Jorgensen Road PERMIT # 1901-0104 RECEIPT # ) 5s U y _i PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT REVISIONS: Revise Tie Beam to Form Beam change from Precast Lintel CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CGC1523983 BUSINESS NAME: Larry Neese, LLC QUALIFIERS NAMED] ADDRESS: 3401 IJS-i CITY: Fort Pierce Neese II PHONE (DAYTIME): 772-361-6580 STATE: OWNERIBUILDER INFORMATION: NAME: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: Terrance Schlitt ADDRESS: 1555 Indian River BLVD Suite B-145 SCANNED ST. LUCIE CO CERT. #: ZIP: FAX: 772-361-6581 I CITY: Vero Beach STATE: FI ZIP: 32960 PHONE (DAYTIME): 772-360-4998 FAQ{: info@schlittengineedng.com 0+ k r` RRIIS101 v NLRRRY NEESE. ROOFING & CONSTRUCTION Revision Comments Permit: 1901-0104 PE: Revision Failed Inspection I111I0111MA ►T1I Formed beam on south end instead of pre -cast lintel Revised Plans Attached SEP 18 2019 Perm'"-' LARRY NEESELLC 3401 SOUTH US HIGHWAY 1-FORT PIERCE, FL 34982 772-361-6580 State Certified Roofing Contractor CCC1330608 N State Certified General Contractor CGC1523983 a w_n wycutvua Click h to Ietuto the main Pelynits page. rt Permit. 190I-0104 Permit Status: Issued Job Description: ADD PATIO ADDITION OVER EXISTING PATIO AREA. To pay a "Inspection fee, please click Eayfg9link for each fee due. You may use Yise, Mastercard, Discover Card, or ecbeck to pay the fee using the Govleller gateway. TO schedule an Inspection, please select Request for each inspection you would like to schedule. Inspection most be scheduled in fie order ofthe Priority listed below. An inspection will not schedule =61 all inspections with a lower Priority number show an "Approved" status and ALL minspection fees have been PAID. TO add a note for the Inspector for scheduled inspections, please select Add Note craernote in Inspection Notes textbox below, and click Update link for each inspection you would lik to add a note for. \ Ifyou are urMble to schedule an inspection or require any essistu=6 please contact the Building Division at (772) 462-2172. Type Cat# Stall permit Type Name Company PhaM Fax at mno-acta 29T75 _—._-.___.._..... Active BUILD RFSIDADDIDON J _,, .._.-......_._�___ TARRY C HEUEU _ ...-.._.-..-... ._-..—.._— LARRY NEESE ILC _ ("2)361-65M _...-.__— Contractor 29238 Red. ROOF -FIBERGLASS SHINGLE IARRT C NEESEn IARRYNEESE ILC QT 361.6580 Requst pod Note Payree Fee Cade Status Want, Date SNeduled Wdelmpeated Insp. to Comments Dupectlm Notes I1W-WMPACIION I AAA Nok Pay F:r: TEST-ORIGINPI- Accepted 1 B/9R019 I SnI2019 so TNWINIOOFFltF ---11(I — --- Add NOII• NY R. 105-FORM BOARD SURVEY -OFRU Approved 1 8/9/2019 e/9/2019 107 FOR PAD LOCATION. Ada Nµe, pat Fre 121-713PIrTE SPRAYAneal'add as acted 1 8/9/2019 819/2019 565 —_— Add Note, Pay Rc �OTHAR 514H ' Dtsapprwed 2 8/1312019 8,113/2019 1126 Fbc 110.SroplansmsRe Add HeC Pay Fe: 110 1IXsappmvai iWIFIyFWNOAT30N 2 8/13/2019 8/13/2019 1126 Fbc110.5reptansandle Permit box at me e.d 110- arm. riveway ' na Noe PCFro FOOTEp/iWrRWTION ADproend 2 8/19/2019 8/14/20i9 1126 RNCON. cranny— I webt 8/13/2019 2:59r14 PM. PermR beat No me and of mo Add NVs pay Fe^ Its-PRE-9AB (OT Approved!2 8/14/2019 8/14/2019 1126 REINspWrIoN. drivowery atentry— HER Web 81012019 3:0035 PM. Pe nit box at the end ofine driveway Add Note Pay rdu 118-00LUMN ;Qyjpp m.o-. 3 9/612019 9/6f2019 237 Sce.Mes at beam iropeaon atentry— Well, 9/5/2019 i q 11:21:30 AM. #FBCIO]9OetoB 5/59.1.The,6edmaMq PermR box at maend 4+" eNadment; to malwsedoesDot math rmo to*utl detal,DTI 9 ThehepreaUt tudeltti mtused,eN d�� And Nat - BEAM 3 9/6/2019 91612019 23]'Y�(i,r1A a :Mn, uWeb lstantry— /^ RE1.I_ �rcf ` I 'y N'"[M an, PAS oft WPaRNs Man, ISK 9/5/2019 ti:21:a9 6159ffi MdY Add Oot .afik �,d Pao Fro •A ��291TIEBFAN 11118�-C011lnx 3 3 OAftSPECTI IL bEINTECf1�K1W. -_ Rmuert I.>_dN,A I LticldfCoun y, hs1RAltdNmrt I ^ =�__ �..—� 140-CONSIRIIC}10N - AEA NOF4 Pai Fx ROUGH FRAMING 9 , 1a11 Note Pay Fe 195-TRI65 DR�` 4 A:q Ram Y11 Fce 13]-STPAPPING 4 FAA Nete Add Fled: Pay Fe Pay Fce _� �184-FlNAL SURVEY- OFFEM 135-ROOFDRY- Mfm Tn I 9 5 TO SHOW RM STRUCNRE. ' MJ Nare F4 Fee IN-WIREIATN_i 5 Add Nr-, Ppy Fe? 167-RWFFOUL 6 Fdtl N.xe _ry ? Fe fSP CnON_� 6 i codeinspeclionpublic.stlucieco.gov 1/2 IN .> OFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT # / . ZC / "O RECEIPT# I SS9-7 PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION RECEIVED 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 SEP 16 2019 (772)462.1553 ST. Lucie County, Permitting APPLICATION FOR BUILDING PERMIT REVIS PROJECT INFORMATION SCANNED LOCATION/SITE BY AI)DRESS: St. Lucie County Kam; �, csj OC9'�% ( . DETAILED DESCRIPTION OF PROJECT STATE of FL REG./CERT. #: BUSINESS NAME: `K v,4 QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: OWNER/BUILDER INFORMATION:. NAME: ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: CITY: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130117 s STATE: Ji• ;' �a ST. LUCIE CO CERT. #: ioM Isal.2:� lIG�� ZIP: ZIP: ZIP: FORM R405-2017 ,�, /L S$o VJ 'RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance Method shall include: RECEIVED irJ This Checklist S E P 16 2919 / ie County, Permitting Z" A Form R405 report that documents that the Proposed Design complies with R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a -ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst -case orientation, name and version of the compliance software tool, name of individual completing the compliance report (one page) and an input summary checklist that can be sed for field verification (usually four pages/may be greater). Ej En y Performance Level (EPL) Display Card (one page) r� VAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 L5 Mandatory Requirements (five pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report (usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed Form R405 Duct Leakage Test Report (usually one page) 76 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC 6/4/2019 10:22:11 AM EnergyGauge® USA 6.0.03 (Rev. 1) - RaRes2017 FBC 6th Ei�, iji01 om n - Page 1 of 1 L» � _ Py a FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RENAR CAYMAN 1763 Builder Name: RENAR HOMES Street: 9620 RIANWOOD COURT PIERCE FL Permit Office: FT PIERCE �0/ Permit Number: 7V City, Stale, Zip: FT , , Owner: WESSON RESIDENCE Jurisdiction: 661100 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1616.0 sgft.) Insulation Area a. Concrete Block - Int Exterior R= 1224.00 ft' 2. Single family or multiple family Single-family cent b. Frame -Wood, Adjacent R-11.0 24.00 ft' 3. Number of units, if multiple family 1 c. N/A ft' 4 d. N/A ft' 4. Number of Bedrooms 10. Ceiling Types (1763.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1763.00 ft' 6. Conditioned floor area above grade (ft') 1763 b. N/A R= ft' ft' c. N/A R= Conditioned floor area below grade (W) 0 11. Ducts R ft' 7. Windows(153.7 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 131 a. U-Factor: Sgl, U=0.54 107.00 ft' SHGC: SHGC=0.25 12. Cooling systems kB34.2 Efficiency b. U-Factor: Sgl, U=0.61 40.00 ft' a. Central Unit 4.2 SEER:14.50 SHGC: SHGC=0.23 c. U-Factor: Sgl, U=0.47 6.67 ft' SHGC: SHGC=0.24 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 33.8 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 3.936 ft. Area Weighted Average SHGC: 0.244 t4.water systems a.. Electric Cap: 40 gallons 8. Floor Types (1763.0 sgft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1763.00 ft' b. Conservation features b. N/A R= ft' None c. NIA R= ft' 15. Credits Pstat Total Proposed Modified Loads: 55.85 SS PASS Glass/Floor Area: 0.087 Total Baseline Loads: 57.75 r d' �a� 1 hereby certify that the plans and specifications covered by Review of the plans and O THE S'p this calculation are in compliance with the Florida Energy specifications covered by this y O� Code. calculation indicates compliance F with the Florida Energy Code. nd„'•%, :•s°`.:"_�40 PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 A I hereby certify that this building, as designed, is in compliance Florida Statutes. lj, �4.5. COD with the Florida Energy WETS OWNER! ENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/4/2019 10:22 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 F RM R405 2017 INPUT SUMMARY CHECKLIST REPORT 0 PROJECT Titlet Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: RENAR CAYMAN 1763 User WESSON RESIDENCE 1 RENAR HOMES FT PIERCE 651100 Single-family New (From Plans) Bedrooms: 4 Conditioned Area: 1763 Total Stories: 1 Worst Case: No Rotate Angle: 270 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # 38 Block/Subdivision: PlatBook: Street: 9620 RIANWOOD CO County: St. Lucie City, State, Zip: FT PIERCE, FL, CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1763 14104 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 Main 1763 14104 Yes 10 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 209 ft 0 1763 ft' ---- 0 0 1 ROOF / v # Roof Gable Roof Type Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 1910 ft' 366 ft' Light N 0.96 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1763 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1763 ft' 0.11 Wood 6/4/2019 10:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 Lint M Qt teeennoV f-U=f-k-I ICT R1=13t71ZT rIJKIVI K4U0-ZU-I 1 uv v t vw...... ^^ • - - - - - WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w IA/mIl Type Space In Arpm 1 N=>W Exterior Concrete Block - Int Insul Main 4.2 66 8 528.0 ft2 0 0.3 0 _ E=>N Exterior Concrete Block - Int Insul Main 4.2 12 8 96.0 ft' 0 0.3 0 -2 3 S=>E Exterior Concrete Block - Int Insul Main 4.2 62 8 496.0.ft' 0 0.3 0 _ W=>S Exterior Concrete Block - Int Insul Main 4.2 34 8 272.0 ft2 0 0.3 0 -4 5 N=>W Garage Frame - Wood Main 11 20 8 160.0 ft2 0 0.5 0.3 0 _ 6 E=>N Garage Frame - Wood Main 11 8 8 64.0 ft2 0 0.5 0.3 0 DOORS # Ornt Door Type Space Storms U-Value WidthArea Ft In In Ft 1 E=>N Insulated Main None .46 3 6 8 20 ft2 _ 2 N=>W Insulated Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 270 degrees). Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening _ 1 N=>W 1 Metal Single (Tinted) Yes 0.54 0.25 N 22.5 ft2 1 ft 4 in 1 ft 0 in None None _ 2 N=>W 1 Metal Single (Tinted) Yes 0.61 0.23 N 40.0 ft2 11 ft 4 in 1 ft 0 in None None _ 3 E=>N 2 Metal Single (Tinted) Yes 0.54 0.25 N 10.0 ft2 1 ft 4 in 1 ft 0 in None None _ 4 S=>E 3 Metal Single (Tinted) Yes 0.47 0.24 N 6.7 ft2 1 ft 4 in 0 ft 2 in None None _ 5 S=>E 3 Metal Single (Tinted) Yes 0.54 0.25 N 22.5 ft2 1 ft 4 in 1 ft 0 in None None _ 6 W=>S 4 Metal Single (Tinted) Yes 0.54 0.25 N 6.0 ft2 1 ft 4 in 1 ft 0 in None None _ 7 W=>S 4 Metal Single (Tinted) Yes 0.54 0.25 N 30.0 ft2 1 ft 4 in 1 ft 0 in None None 8 N=>W 1 None Single (Tinted) Yes 0.54 0.25 N 16.0 ft2 1 ft 4 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 440 ft2 440 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1645.5 90.33 169.89 .1233 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.2 33.8 kBtu/hr 1 sys#1 614/2019 10:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 unr rT cr reeenncV I`U=1-1 f ICT RPPART FORMR40b-ZUI/ . UIVKInra.. .._ —.-- COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 14.534.2 kBtu/hr 1026 cfm 0.75 1 sys#1 HOT WATER SYSTEM ` # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / --- Supply — — Return -- Air CFM 25 CFM25 HVAC # v # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 131 ft- Attic 54 ft' Default Leakage Garage (Default) (Default) 1 1 _ TEMPERATURES Programablee Thermosta[[t:]]Y C[[ei]]ling Fans: [ �]j Heat ng Jan Feb Mar �X [ ] rj JMay un Jul Aug �( [ Sep L.1 ] Oct ov r(X Nov Dee r(�t Dec IX) [XJ lxJ Venting [[ 1) Jan [I( ])) Feb ((XJ11 Mar EX1 Apr [ ] May Jun 111 Jul 1 Aug E E ]]] Sep lXl [X� [ Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) PM 80 80 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) PM 78 78 78 78 78 78 78 ' 78 78 78 78 78 78 Heating (NID) PM 68 68 68 68 68 68 68 68 68 6B 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 68 66 68 66 PM 68 68 68 68 68 68 68 68 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 0 1 - Electric Heat Pump 0% 1 - Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibsls .ft. 0 fN 0 ft 0.3 Main 6/4/2019 10:22 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software :Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 Garage c) AHU location 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 34.2 a) Split system SEER 5. Is this a worst rase? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1763 d) Room unit/PTAC EER e) Other 14.5 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.555 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.244 14. Heating system: Capacity 33.8 c) Area 7c. 153.7 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) Be. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 8.20 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.92 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.2 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c, d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: 9620 RIANWOOD COURT City/FL Zip: FT PIERCE. FL 6/4/2019 10:22:13 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) atory Reauirements for Residential Performance, Prescriptive and ERI Methods ADDRESS:, 9620 RIANWOOD COURT Permit Number: FT PIERCE, FL, II MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statutes) requires the EPL display card to be Included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. ❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelo'ibe building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance El with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. ❑ R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air Ieakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAMA/ WDMA/CSA 101/I.8.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site -built windows, skylights and doors. 6/412019 10:22 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gesketed and any water lines and ducts in the room Insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the Interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways ' for air distribution systems shall be considered duds or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(% (g) or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if Installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstrudion test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or below 55°F (13°C) shall be insulated to a minimum of R-3. El caused Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return ❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 6/4/2019 10:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) Rj03.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat trans installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'/z inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100"F to 140°F (38°C to 60'C). ❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. ❑ R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be Installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical El ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be Insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFMNVATT) AIRFLOW RATE MAXIMU (CFM) Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916 6/4/2019 10:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less ttian the 6alculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by aFlorida-registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling rapacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F (4.8°C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning Ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa healers shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 6/4/2019 10:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool healers shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas (MandatorAhe energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high -efficacy lamps or not less than 75 percent of the permanently Installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 6/4/2019 10:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: RENAR CAYMAN 1763 Builder Name: RENAR HOMES Street: 9620 RIANWOOD COURT Permit Office: FT PIERCE Y City, State, Zip: FT PIERCE, FL, Permit Number: O ul Owner: WESSON RESIDENCE Jurisdiction: 661100 _ U Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation above -garage and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinkliar cover plates and MMIIq or ciallinas a. In addition, inspection of log walls shall be In accordance wlm me provisions or iw-vuu. 6/4/2019 10:22 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance gn17 Flrnrida Ruildina Code. Energv Conservation, 6th Edition Jurisdiction: 661100 Permit #: Job Information, Builder: RENAR HOMES Community: Lot: NA Address: 9620 RIANWOOD COURT City: FT PIERCE State: FL Zip: Air Leakage Test Results' Passingresulfsmustmeet either the Performance; Prescriptive, or ERI Method O PRESCRIPTIVE METHOD -The building or dwelling: uri t shall be tested and verified'as having an air leakage rate of not exceeding 7 air changes per -hour at a pressure of 0.2 inch'w.g. (5o Pascals) in Climate Zones 1 and 2. Q PERFORMANCE or ERl'METHOD-The.building,or"dwelling unit shall be tested and verified as having�an air leakage rate of not exceeding the selected ACH(50) value, as shown on Form R405-2017 (Performance)orR406-2017 (ERI), section labeled as infiltration, sub-sectionACH50. ACH(50) specified on Form R405-2017-Energy Cato (Performance) orR406-2017-(ERI).` 7.000 X 60 _ 14104 Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans PASS S Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or Individuals licensed as set forth in Section 489.105(3)(f), (g), or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 614/2019 10:22:15 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Cayman 1763 Wesson 9620 Rainwoodcourt HVAC Load Calculations for Renar Homes Prepared By: Preferred Air Conditioning & Mechanical 1643 Donna Road West Palm Beach, FI. 33409 561-689-1093 Tuesday, June 04,2019 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac - Residential & Light Commercial HVACLoads Elite Software Development, Inc. Preferred Air Conditioning &Mach _ Cayman 1763 Wesson 9620 Rainwoodcourt West Palm Beach, FL, 33409 Page 2 [Project Report General Project Information Project Title: Cayman 1763 Wesson 9620 Rainwoodcourt Designed By: Preferred Air Cinditioning & Mechanical Project Date: 06-04-2019 Client Name: Renar Homes Company Name: Preferred Air Conditioning & Mechanical Company Address: 1643 Donna Road Company City: West Palm Beach, FI. 33409 Company Phone: 561-689-1093 Company E-Mail Address: Company Website: GETCOLD.NET Design Data Reference City: Fort Pierce, Florida Building Orientation: Front door faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 78 59% 50% 75 61 Check Figures Total Building Supply CFM: 1,048 CFM Per Square ft.: 0.648 Square ft. of Room Area: 1,618 Square ft. Per Ton: 586 Volume (ft'): 12,944 Building Loads Total Heating Required Including Ventilation Air: 38,561 Btuh 38.561 MBH Total Sensible Gain: 25,762 Btuh 78 % Total Latent Gain: 7,378 Btuh 22 % Total Cooling Required Including Ventilation Air: 33,140 Btuh 2.76 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:1... \RENAR CAYMAN 1763.rh9 Tuesday, June 04, 2019, 10:46 AM - Residential &Light CommercialHVAC Loads Elite Software Development, Inc. Cayman 1763 Wesson 9620 Rainwoodoueferred rRhvac Air Conditioning & MechPa e3 est Palm Beach FL 33409 TOW Building Summa Loads Area Sen Let Sen Total Component Descri tion Quan Loss Gain 0 Gain 3,221 Gain 3,221 RENAR SGH: Glazing-RENAR SINGLE HUNG, U-value 55.5 1,678 1.08, SHGC 0.49 RENAR FIXED: Glazing -FIXED .47 / .24, U-value 0.47, 13.2 174 0 160 160 SHGC 0.24 RENAR SGD: Glazing-SGD .61 / .23, U-value 0.61, 52.8 902 0 739 739 SHGC 0.23 RENAR SGH: Glazing-RENAR SINGLE HUNG, U-value 30 454 0 400 400 0.54, SHGC 0.25 7A-3: Glazing -Glass or plastic block, narrow ribs or flutes, 13.2 222 0 480 480 fiberglass screen, no coating, U-value 0.6, SHGC 0.33 11 P: Door -Metal - Polyurethane Core, U-value 0.29 17.8 161 0 174 174 174 174 11 D: Door -Wood - Solid Core, U-value 0.39 17.2 49 187 203 0 0 111 111 13A-4ocb: Wall -Block, board insulation only, R-4 board insulation, open core, brick finish, U-value 0.148 R-4.2: Wall -Custom, STUCCO BLOCK R4.2 DRYWALL, 1093.5 17,881 0 11,112 11,112 U-value 0.584 12C-Obw: Wall -Frame, R-13 insulation in 2 x 4 stud 174.8 445 0 191 191 cavity, no board insulation, brick finish, wood studs, U-value 0.091 16B-30: Roof/Ceiling-Under Attic with Insulation on Attic 1582 1,418 0 2,532 2,532 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-30 insulation, U-value 0.032 36 32 0 81 81 16A-30: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Unvented Attic, No Radiant Barrier, Any Roofing Material, Any Roof Color, R-30 insulation, U- value 0.032 22A-ph: Floor -Slab on grade, No edge insulation, no 188 7,147 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil U value 1.358 .... -. ... ..... ..,.. --- _.._... .- ............. _._..... ........ ..... ... .... . ...._..... Ota $ubtIS for StfUCtUfe. 30,904 0 19,350 19,350 People: 2 400 460 860 Equipment: 0 0 3 0 3 Lighting: Ductwork: 1 3,041 752 1,973 2,725 Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Ventilation: Winter CFM: 150, Summer CFM: 150 4,616 6,226 2,473 8.698 AED Excursion: 0 0 11503... 1,503 Total Building Load Totals. 38,561 7,378 25,762 33,140 Check Fi ures Total Building Supply CFM: 1,048 CFM Per Square ft.: 0.648 Square ft. of Room Area: 1,618 Square ft. Per Ton: 586 Volume (W): 12,944 Building -Loads Total Heating Required Including Ventilation Air: 38,561 Btuh 38.561 MBH Total Sensible Gain: 25,762 Btuh 78 % Total Latent Gain: Total Cooling Required Including Ventilation Air: 7,378 Btuh 33,140 Btuh 22 2.76 % Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. CA ... \RENAR CAYMAN 1763.rh9 Tuesday, June 04, 2019, 10:46 AM Rhvac - Residential & Light Commercial HVAC Loads _ Elite Software Development, Inc. Preferred Air Conditioning & Mech Cayman 1763 Wesson 9620 Rainwoodcourt West Palm Beach FL 33409 Page 4 Total Building Summary Loads (cont'd Notes , Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ...\RENAR CAYMAN 1763.rh9 Tuesday, June 04, 2019, 10:46 AM i Rhvac - Residential & Light Commercial HVAC Loads - Elite Software Development, Inc. Preferred Air Conditioning & Mech • Cayman 1763 Wesson 9620 Rainwoodcourt West Palm Beach FL 33409 Pa e 5 S'ste(n 1 Room Load Summary Htg; : Min " "'. ; Run Run Clg... Cig Min Act Room Area Sens - Htg _Duct Duct Sens Lat Clg Sys No Name Sf' '' ' Btuh .' CFM °. ' Size Vel . Btuh Btuh CFM- CFM ---Zone 1--- 1 Bath 2 55 683 9 1-4 217 416 0 19 19 2 Bedroom 2 168 7,907 103 1-9 565 5,485 0 250 250 3 Foyer 42 927 12 1-4 320 614 0 28 28 4 Living / Dining 462 1,520 20 1-4 638 1,224 0 56 56 5 Family Room 96 3,836 50 1-6 534 2,305 0 105 105 6 Kitchen 120 1,968 26 1-4 609 1,169 0 53 53 7 Laundry 50 2,155 28 1-4 476 912 0 41 41 8 Bedroom 4 / Den 130 2,714 35 1-6 510 2,202 0 100 100 9 Wic 1 36 2,255 29 1-4 641 1,229 0 56 56 10 Master Bedroom 195 6,333 69 1-8 476 3,656 400 166 166 11 Master Bath 121 2,160 28 1-5 556 1,667 0 76 76 12 Bedroom 3......._.._ . . 31 _........ 1 6 .-.._.-..... 500...._...2159 ......_..._ 0............. 98...._...... ....3..$.. Ventilation 4,616 2,473 6,226 Duct Latent 657 Return Duct .......... . ._._ .... 84 ..... 250 95 ...-. .._ System 1 total -... _ 1,618 38 561, 440 -.. - 25 762 7 378 1 048 1 048 .... System 1 Main Trunk Size: 12x16 in. Velocity: 786 ft./min Loss per 100 ft.: 0.092 in.wg Cooling System Summary Cooling Sensible/Latent Sensible latent Total Tons S lit, ` Btuh Btuh Btuh Net Required: 2.76 78%/22% 25,762 7,378 33,140 Actual: 2.85 75% / 25% 25,650 8,550 34,200 Equipment Data I - Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: CH 14N B036*0**B* CH 14 N B036*0**B* Indoor Model: FB4CNP042L Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 8.2 HSPF 14.5 SEER Sound: 0 0 Capacity: 33,800 Btuh 34,200 Btuh Sensible Capacity: n/a 25,650 Btuh Latent Capacity: n/a 8,550 Btuh AHRI Reference No.: n/a 9162515 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain: 25,762 Btuh, Lat..gain: 7,378 Btuh, Sen. loss: 38,561 Btuh, Entering clg. coil DB: 77.4F, Entering cig. coil WB: 55.2F, Entering htg. coil DB: 60.3F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req, clg. airflow: 1048 CFM, Req. htg. airflow: 440 CFM CA ...1RENAR CAYMAN 1763.rh9 Tuesday, June 04, 2019, 10:46 AM