HomeMy WebLinkAboutSOIL NUCLEAR GAUGElft&®Ardaman Soil Nuclear Gauge
s&-Assoclates,,lnc. rmit ,90� o49r21riliih
Report Date: 3/15/2019
Pert sL Lucie Branch Test Method: ASTM D 6938
Fladda CA No. 5950
460 NW Concourse Place, Unit 1
Poet St. Lucie, FL 34986
Phone: 712-976e072
Client:
Renar Development Corp.
3725 S. East Ocean Boulevard, Suite 101
Stuart, FL 34996
RECEIVED
Project:
113-15-66-54 B
Morningside sSTel "It-6teuntyr R9rMittine
Fort Pierce --
Fort Pierce, FL
Test Results
Test#
137
Retest
Of
Test
Date
3/7119
ProctorlD
19-046
Method
A
Soil
Classification
—
Optimum
Moisture
N
10.5
Maximum
Dry Density
(pcf)
1 126.5
In Place
Moisture
N
6.2
In Place
Dry Density
(pcf)
126.1
Probe
Depth
(in)
12
Percent
Compaction
100 -
Min Comp.
(%)
98
Remark
Pass
Test Information
Test if
I Test Location
Elevation
IReference
Gauge
Make / Model / SN / Calibrated
I Field Technician
137
Building - Slab on Grade: House Pad for Lot 38 on Rainwood Court. Center
-1.0
Top of Pad
CPN / MC-3! M330907151 /
Tech, Port St. Lucie
Remarks
Comments
�r� hl AICI'-Y
Pass: Density Pass
Tests are "Direct Transmission' (Method A) unless probe depth is noted as
'Backscatte'. Gauge calibration data on file with the testing agency.
BY
St. v
St. Lucie County
ARDAMAN &ASSOCIATES, INC.
FL- Certificate of;Authorizabon No. 5950
h
Mark Zrallack; P!F.
Construction Services Manager
Florida License -No, 8650) 1
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.