Loading...
HomeMy WebLinkAboutSOIL NUCLEAR GAUGElft&®Ardaman Soil Nuclear Gauge s&-Assoclates,,lnc. rmit ,90� o49r21riliih Report Date: 3/15/2019 Pert sL Lucie Branch Test Method: ASTM D 6938 Fladda CA No. 5950 460 NW Concourse Place, Unit 1 Poet St. Lucie, FL 34986 Phone: 712-976e072 Client: Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 RECEIVED Project: 113-15-66-54 B Morningside sSTel "It-6teuntyr R9rMittine Fort Pierce -- Fort Pierce, FL Test Results Test# 137 Retest Of Test Date 3/7119 ProctorlD 19-046 Method A Soil Classification — Optimum Moisture N 10.5 Maximum Dry Density (pcf) 1 126.5 In Place Moisture N 6.2 In Place Dry Density (pcf) 126.1 Probe Depth (in) 12 Percent Compaction 100 - Min Comp. (%) 98 Remark Pass Test Information Test if I Test Location Elevation IReference Gauge Make / Model / SN / Calibrated I Field Technician 137 Building - Slab on Grade: House Pad for Lot 38 on Rainwood Court. Center -1.0 Top of Pad CPN / MC-3! M330907151 / Tech, Port St. Lucie Remarks Comments �r� hl AICI'-Y Pass: Density Pass Tests are "Direct Transmission' (Method A) unless probe depth is noted as 'Backscatte'. Gauge calibration data on file with the testing agency. BY St. v St. Lucie County ARDAMAN &ASSOCIATES, INC. FL- Certificate of;Authorizabon No. 5950 h Mark Zrallack; P!F. Construction Services Manager Florida License -No, 8650) 1 AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL.