Loading...
HomeMy WebLinkAboutEVALUATION REPORTNEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit-#13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Polyglass USA, Inc. Evaluation Report P12060.02.09-R24 1111 West Newport Center Drive SCANNED FL5259-R28 Deerfield Beach, FL 33442 BY Date of Issuance: 02/24/2009 (954) 233-1230 St. Lucie County Revision 24: 01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 CERTIFICATION OF INDEPENDENCE: The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 01/24/2018. This does not serve as an electronically signed document 1. NEMOletc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOietc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Eat Examination ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Wind Uplift ERD (TST 6049) Physical Properties ERD (TST 6049) Wind Uplift ERD (TST 6049) _ _ Wind Uplift ERD (TST 6049) Wind Uplift ERD (TST 6049) Wind Uplift ERD (TST 6049) Wind Uplift ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties , ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Wind Uplift ERD (TST 6049) Physical Properties ERD (TST 6049) Wind Uplift ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ERD (TST 6049) Physical Properties ICC-ES (EVIL 2396) IBC Compliance Miami -Dade (CER 1592) HVHZ Compliance Polyglass USA Manufacturing Affidavit Polyglass USA PA Affidavit Polyglass USA Materials Affidavit UL, LLC. (QUA9625) Quality Control 4. PRODUCT DESCRIPTION: ONEMOjetc. Reference Date P40390.08.12-1 08/06/2012 P40390.08.12-2 08/07/2012 C41420.09.12-3 09/11/2012 P39680.03.13 03/04/2013 P45370.04.13 04/26/2013 P1738.02.07-R2 04/29/2013 11757.04.01-1-R1 04/30/2013 P41630.08.13 08/06/2013 P11751.05.03-R1 11/26/2013 P11781.11.03-R1 11/26/2013 P45270.05.14 05/12/2014 6020.07.14-1 09/08/2014 6020.09.14-2 09/08/2014 6020.09.14-3 09/08/2014 6020.09.14-4 09/08/2014 6020.09.14-5 09/08/2014 6020.09.14-6 09/08/2014 P46520.10.14 10/03/2014 P43290.10.14 10/17/2014 PLYG-SC7550.03.15 03/24/2015 P40390.04.15 04/03/2015 P44360.10.14-R1 05/18/2015 PLYG-SC8080.05.15-1 05/20/2015 PLYG-SC8905.05.16-1 05/17/2016 PLYG-SC8080.07.16 07/16/2016 PLYG-SC12025.10.16 10/12/2016 PLYG-SC13040.12.16 12/27/2016 PLYG-SC11900.03.17 03/10/2017 PLYG-SC12115.08.17 08/08/2017 ESR-1697 11/01/2014 NOA 14-0717.08 01/22/2015 Products Current 02/18/2009 Mule -Hide Cross Ltg - — 03/01/2008 Polystick SA Compound 08/18/2011 Service Confirmation Exp. SO/05/2018 4.1 ..Mechanically Fastened Underlayments: - 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1-2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.1.3 Polyglass GZ Base is a fiberglass -reinforced, asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R24 Certificate of Authorization H32455 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24:01/24/2018 Page 3 of 14 ONEMOjetc. 5.5 Allowable Roof Covers: _ TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes & Shingles Slate Elastobase Yes Yes (Raze Sheet in 2-ply system) Yes (ease Sheet in 2-ply system) Yes Yes Yes Elastobase P Yes Yes lease Sheet in 2-ply system) Yes (Base Sheeting-plysYstem) Yes Yes Yes Polyglass G2 Base No Yes (ease Sheet in 2-ply system) Yes (Base Sheet in 2-plysystem) No No No Polyglass APP Base No Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-pp system) No No No Polystick M7S or MTS PLUS Polystick lR-Xe _Yes Yes _Yes No No No Yes No _ Ves _ Yes Yes Yes Polystick TUP No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick TU Max No Yes Yes (See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Elastoflex G TO Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Yes Yes Yes (See 55.1) No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIDNS I Adhesive Florida Product Underlayments Approval DAP Foam Touch'n Seal StormBond Roof FL14506 Polystick TU Plus, Polystick TU Max Tile Adhesive DOW TIIeBOnd"' FL22525 Polystick TO P, Polystick TO Plus, Polyflex SAP or Tile Pro Polystick TO P, Polystick TO Plus, Polystick TO Max, Polystick Tile Pro, ICP Adhesives Polyset® AH-160 FL6332 Elastoflex G TO, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polystick TO P, Polystick TO Plus, Polystick TO Max, Polystick Tile Pro, ICP Adhesives Polyset® RTA-1 FL6276 Elastoflex G TO, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, U.C. Evaluation Report P12060.02.09-R24 certifimte of Authari:ation#32455 6a"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 5 of 14 ONEMOletc. 5.6 Allowable Substrates: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primedstructural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: ➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. NEMO ETC, LLC, Evaluation Report P12060.02.09-R24 Certifimte of Authormotion#32455 6'"EDITION (2017)FBC NON-HVHZ EVALUATION FL5259-RZB Polyglaw Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 6 of 14 ONEMOletc. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase, Elastobase P or Mule -Hide Nail Base: 6.3.1 Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type 11 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the 'Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April2012 (04-12) Installation Manual. 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers: All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule - Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed. All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand roller to ensure full contact and adhesion. For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details NEMO ETC, I.I.C. Evaluation Report P32060.02.09-R24 Certifimte of Authorization#32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-RZ8 Polyglas Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 12 of 14