HomeMy WebLinkAboutBUILDING SITE PLANSFILE COPY PRODUCT APPROVAL SUBMITTAL AFFIDAVIT BUILDING PERMIT: BUILDING ADDRESS: LOT 38 _ BLOCK * _ PHASE 31A, RAINWOOD COURT, FT. PIERCE, FLORIDA 34945 CONTRACTOR: GLENN DAVIS CBC1261228 OPENING SCHEDULE SWING DOORS, OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS, & SKYLIGHTS: OPENING ID PRODUCT MODEL # MANUFACTURER GLASS ATTACHMENT METHOD PRODUCT APPROVAL DESIGN PRESSURES HEAD: 1/4" X 3-3/4" TAPCONS SPACED 3" FROM CORNERS, 3" & 6" FROM MULLION. JAMBS: 3068 EXTERIOR SWING DOOR FIBER -CLASSIC THERMA-TRU 3/16"TEMPERED 1/4" X 3-3/4" TAPCONS SPACED 3" FROM CORNERS, 14" O.C. MAX. SILL: 1/4" DIA. X 2-1/4" FL15225.5 +40.0-40.0PSF W/ SDLT. SMOOTH STAR TAPCONS SPACED 3" FROM CORNERS, 3" & 6" FROM MULLION. STEEL TRACK BRACKET TO WOOD: 5/16" X 1-5/8" LAG SCREW (FULLY THREADED) HEX 16070 OVHD OVERHEAD DOOR MODEL 9100 WAYNE DALTON «>> WASHER HEAD ONE PER BRACKET - (5) BRACKETS TOTAL PER VERTICAL STEEL TRACK FL9174.6 +39.2 -43.7 PSF ALL ANCHORS ARE 3/16" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT) 8068 S.G.D. SLIDING GLASS DOOR SERIES 420 MI WINDOWS AND DOORS 3/16" TEMPERED HEAD: SPACED 6" FROM CORNERS, 17" O.C. MAX. JAMBS: SPACED 6" FROM CORNERS, 17" FL15332.6 +/- 40.0 PSF (MIN) O.C. MAX. SILL: SPACED 6" FROM CORNERS, 17" O.C. MAX. ALL ANCHORS ARE 3/16" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT) 0 WINDOW 185 SH MI WINDOWS AND DOORS 1/8" ANNEALED ANCHORS 2" FROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX. FL17499.2 +/- 60.0 PSF (MIN) ALL ANCHORS ARE 3/16" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT) 03) WINDOW 185 SH MI WINDOWS AND DOORS 1/8" ANNEALED ANCHORS 2" I -ROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX. FL17499.2 +/- 60.0 PSF (MIN) PROVIDE LADDER REINFORCING & WALL TIES AT ALTERNATE LAYERS, PROVIDE (2) 1/4" DIA. GLASS BLOCK 8"x8"x4" MULIA, INC. TAPCONS AT EACH WALL TIE WITH 1-1/4" MIN. EMBEDMENT NOA 15-0916.12 +/- 90.0 PSF (MIN) ALL ANCHORS ARE 3/16" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT) 0 WINDOW 185 SH MI WINDOWS AND DOORS 1/8" ANNEALED ANCHORS 2" FROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX. FL17499.2 +/- 60.0 PSF (MIN) ALL ANCHORS ARE 3/16" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT) 0 WINDOW 185 SH MI WINDOWS AND DOORS 1/8" ANNEALED ANCHORS 2" I -ROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX. FL17499.2 +/- 60.0 PSF (MIN) ALL ANCHORS ARE 3/16" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT) WINDOW 185 SH MI WINDOWS AND DOORS 1/8" ANNEALED ANCHORS 2" I -ROM CORNERS, HEAD: 16" O.C. MAX., JAMBS: 16" O.C. MAX. FL17499.2 +/- 60.0 PSF (MIN) GALV. ROOFING NAILS, 11 OR 12 GA., WITH AT LEAST 3/8" DIA. HEADS, LONG ENOUGH ASPHALT SHINGLES CAMBRIDGE AR TAMKO BUILDING « » TO PENETRATE THROUGH PLYWOOD. USE 4 NAILS PER SHINGLE PLACED 6-1/8" FL.18355.1 PRODUCTS, INC. ABOVE BUTT EDGE, APPROX. 1" & 13" FROM EACH END & 1/2" ABOVE EACH CUTOUT. PROVIDE T-NAILS AT 12" O.C. IN F-CHANNEL SLOT ON MASONRY, PROVIDE TRIM NAILS EXTERIOR SOFFIT ALUMINUM SOFFIT AMERICAN CONSTRUCTION MATERIALS «>> ATTACHED THROUGH FASCIA AT 16" O.C. FL12019 +/- 50.0 PSF (MIN) "SAFETY EDGE" TOWN & COUNTRY METHOD OF ATTACHMENT: DIRECT MOUNT HURRICANE SHUTTERS STORM PANELS INDUSTRIES, INC. «>> ALL ANCHORS ARE 1/4" DIA. TAPCONS (1-1/4" MIN. EMBEDMENT) FL 12856.2 +/-54.0 PSF (MIN) 33 PSF: 16" O.C. SPANS UP TO 5', 9.9" SPANS UP TO 9'-2", 38 PSF: 15.8" O.C. SPANS UP TO 5', 8.6" SPANS UP TO 9'-2", 47 PSF: 12.7" O.C. SPANS UP TO 5', 7" SPANS UP TO 9'-2", 54 PSF: 11.1" O.C. SPANS UP TO 5', 6.1" SPANS UP TO 9'-2" TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND WIND DESIGN SEISMIC SUBJECT TO DAMAGE FROM WINTER ICE BARRIER FLOOD AIR MEAN SNOW Speeds Topographic DESIGN t Weatherng' Frost line° Termite` DESIGN UNDEPLAYMENT HAZARDSs FREEZING ANNUAL LOAD (mph) effects" (NA) CATEGORY depth TEMP` REQUIRED" INDEX TEMP' N/A See Fig. R301 2(4) NIA Negligible N/A Very NIA N/A N!A Heavy For ST: 1 pound per square foot = 0 0479 kPa, 1 mile per hour = 0 P17 mrs. a. Weathering is"neglible" for concrete as determined from the Weathering Probability Map [Figure R301. �(3)1. The grade of masonry unds shall be determined from ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C 652, U. Reserved. c. Termite Infestation per Figure R301 2(6) is'Very heavy." d. Wind speed shall be from the basic wind speed map [Figure R301.2(4)]. Wind exposure category shall tre determined on a site -specific basis in accordance with Secure R301.2A.4. e. The outdone design dry-bulb temperature shall be selected from the columns of 97 1/,-percent values Fir armor- Appends D of the Florida Building Cade, Plumbing- Deviations from the Appendix D temperatures shall be permitted to reflect local dimates or local weafher experience as determined by the building offiaal. f. Reserved. g. The applicants governing body shall, by local tbodpfain floodplain management ordinance, specify (a) rife date m the Jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) Me date(s) of the Flood Insurance Study and (c) the panel numbers and dates of all currently effective FIRM and FBFM, or other flood hazard map adopted by the =uthonty having junsi iction, as amended h- Reserved. i. Reserved. j. Reserved. k. Reserved. NOTE: THE CELLULOSE INSULATION TO BE USED COMPLIES WITH THE REQUIREMENTS OF SECTION R302.10 AND MEETS THE FLAME SPREAD INDEX OF NOT MORE THAN 25 AND THE SMOKE -DEVELOPED INDEX OF NOT MORE T HAN 450. NOTE: THE WALL AND CEILING FINISHES COMPLIES WITH THE REQUIREMENTS OF SECTION R302.9.1 AND MEETS THE FLAME SPREAD INDEX OF NOT MORE THAN 200 AND COMPLIES WITH THE REQUIREMENTS OF SF=CTION R302.9.2 AND MEETS THE SMOKE -DEVELOPED INDEX OF NOT MORE THAN 450. ATTIC VENTILATION CALCULATION: VENTILATION REQUIRED: ATTIC AREA = 2.353-3 SOL FT. VENTILATION AREA REQUIRED = 2,343.0 SO. FT. / 150 (F.B.C. R806.2) = 15.62 SQ. FT. PARAMETERS: LINEAR FEET OF 16' WIDE SOFFIT = 165.5, 12' YADE SOFFIT = 43.1', 8' WIDE SOFFIT = 49-V SQUARE FOOTAGE OF SOFFIT = (165.5' X 1.33') + (43.1' X 1.0') + (49.0' X .67') = 296.0 SQ. FT. NET FREE AREA OF VENTILATION FOR ACM TRIPLE 4 OR QUAD 4 FULL VENT NARROW PATTERN SOFFIT = 11.74 SQ. IN. / SQ, FT. VENTILATION PROVIDED: SOFFIT VENTILATION PROVIDED = 296.0 SQ. FT. X 11.74 SQ. IN. / SQ. FT. X 1 SO. FT. / 144 SQ. IN. = 24.14 SQ. FT. CONCLUSION: VENTILATION PROVIDED = 24.14 SQ. FT. > VENTILATION REQUIRED = 15.62 SQ. FT., THEREFORE SOFFIT VENTILATION IS ADEQUATE I have reviewed the above product approval information and approved it. Name: i ry/� ✓`YV I Signature: Certification Number: A"G) Z %0) Date: /A"D f i 3CG'- DRAWING INDEX CVR A-1.0 A-2.0 A-3.0 A-4.0 A-5.0 A-6.0 A-6.1 A-6.2 A-7.0 A-8.0 INDEX / PROJECT INFORMATION FOUNDATION PLAN FLOOR PLAN BUILDING ELEVATIONS ROOF / FRAMING PLAN ELECTRICAL PLAN WALL SECTIONS / NOTES WALL SECTIONS / NOTES WALL SECTIONS / NOTES INTERIOR ELEVATIONS HVAC PLAN COMPONENTS AND CLADDING WIND PRESSURES PER 2017 FLORIDA BUILDING CODE USING INTERIOR ZONE COEFFICIENTS AREA OF OPENINGS (SO. FT.) DESIGN PRESSURE 0 to 19.9 27.7 PSF / -313.0 PSF 20 TO 49.9 26.4 PSF / -28.7 PSF 50 TO 99.9 24.7 PSF / -27.0 PSF 100 TO 499.9 23.5 PSF / -25.9 PSF 500 AND ABOVE 20.6 PSF / -22.9 PSF USING END ZONE COEFFICIENTS AREA OF OPENINGS (SO. FT.) DESIGN PRESSURE 0 to 19.9 27,7 PSF / -37.0 PSF 20 TO 49.9 26.4 PSF / -34.5 PSF 50 TO 99.9 24.7 PSF / 411.2 PSF 100 TO 499.9 23.5 PSF / -28.7 PSF 500 AND ABOVE 20.6 PSF / -22.9 PSF *PLANS DESIGNED TO COMPLY WITH THE 2017 FLORIDA BUILDING CODE (6TH EDITION) TYPE OF CONSTRUCTION: CBS X BUILDING DESIGN: ENCLOSED X ULTIMATE DESIGN WIND SPEED:140 MPH NOMINAL DESIGN WIND SPEED: 124 MPH BUILDING CATEGORY: it EXPOSURE:B INTERNAL PRESSURE COEFFICIENT: +/- 0.18 IMPORTANCE FACTOR: 1 MEAN BUILDING HEIGHT: 15' OVERHANG:1.33 FT OPEN 160 MPH X ROOF PITCH: 6 /12 COMPONENTS AND CLADDING WIND PRESSURES: ROOF DEAD LOAD: (SHINGLES) 17 PSF (TILE) SHUTTERS: YES X IMPACT RESISTANT ASSEMBLY: YES VLe; NO X PARTIALLY ENCLOSED 17CI MPH MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE -RESIDENTIAL (6TH EDITION) m W 0 �0 � W > �m a 0 c, W Lu z mn Q m0 gU ��U LOUg �Lx OLLm WZ aZ �W� 00 I � aof 1 n O _ FIN-, W z 1-wwag (1) of Q�On 1r. MICHAEL C. ANDERSON WIq I(� FL. LIC. AR0017305 PLAN REVIEW REVISIONS 11 MASTER PLAN REVISION 10-16-18 oCrD Q-4 IZ, w � q W o O Fq ti C�6 �� w CO CYD O to CD r N o on W N W z _[BMX � DO " of Q N �L D-jD�c)co II J m p � N J ED < W (00 Z0Qh LLI LLJI-W to Z O W J W PROJECT NO. 17-015-038 DATE DRAWN 8-7-18 DRAWN BY MCA CAYMAN 1763 B3 LIVING 1763 SQFT GARAGE 387 SQFT LANAI 148 SQFT ENTRY 38 SQFT TOTAL 2336 SQFT CUBIC VOLUME OF CONDITIONED SPACE _ 14,816.1 CUBIC FEET SHEET CVR 3C Nlr=0 BY UCIe CQt title I ,;;,-n" 36" SQ. X 16" DEEP CONC. FTGS. W/ (3)-#5 EACH WAY 15'-0" I ■■ ■■ L rJ G L—I J 23'-8" 14'-4" I o 1 I ^ - 7'-0" 6'-10" 5'-2" 4'-8" w G G o I o 1 0 C D ' I 8'-0" 3'-8" I o of 00 I E r A1-1 A N � I ■ ■ ■ i� HB �j I L--- — — — — — — - 3' ? 1 co 1 /2" 1'-8" 2'-6" N RECESS SLAB 7 5/8" \ FOR S.G.D_01) — — — — _ 0 1 I ap o LAV LAV I U) ■ N I M o II rn INDICATES C.M.U. CELL FILLED W/ CONCRETE AND (1) #5 VERT. I REBAR CONT. FROM FOOTING °p TO TIE BEAM (TYPICAL) I co WC SH WR. ■ 1 9'-4 1 /8" ■ I 3E1 E2 S SOLRAB 3 1 /2" 10'-7 5/8" 1 °D I SHOWER o in I I in II SINK `' / ■ I I I DISP. I ■ o_ I 0'-0" I I I I A REFERENCE II BM i a ■ FINISH FLOOR cD 1 I. o I 4" 2500 PSI CONC. SLAB W/ I A FIBER MESH, ON 6 MIL POLY VAPOR DARRIER OVER TERMITE 'n r` TREATED COMPACTED CLEAN 1 `n ■ FILL. I M I I I I• W. - 4 ■ I yHl 'n ■ WH H1 I o RUB/SHWR WC B1 , I 7'-11 7/ d iv ® LAV 1 I R ■ r-- --- — II tot I I I L2- I w I 1'-1 5 8" 1 d o I 2'-2 1/2" 1 v' 1 I w \ 1 I I 1to D I D A co I - - 1 - 1 t m ■i N I I I G � I I ' 00 1 � a0 I 1 roj SLOPE DOWN 1" I I M AT GAR. DOOR m 00 I 1 1 T'j L — A B 5-2" 3'-7" 20" 16'-0" 20" 12'-4" 6'-4" 19'-4" 38'-0" N 6x6 - 1Ox10 WWF 6x6 - 10x10 WWF w_ OR FIBER MESH < CONC. OR FIBER MESH Q Im o GRADE �.� L L 8" 1'-4" A DETAIL 1 CONC. A/C PAD > SLAB VARIES -- Z- - b 2-#5 # BARS BARS -4" 2'-0" B DETAIL C DETAIL i 1 V) 6x6 - 1000 WWF CONC. w OR FIBER MESH SLAB a SLAB SLOPE SLAB 1 -0" is* GRADE2—# GRADE BA-1 BELOW BARS D DETAIL F DETAIL CONC. 1-#5 SLAB BAR G DETAIL 1 5 1 2" FRAME 7 5/8" BLOCK w CONC. SLAB -i ft � 2-#5 8 1'-4" BARS DETAIL - S.G.D. 1 CONC. 8 VARIES 8" SLAB N SHOWER RECESS L DETAIL 1 NOTE: ALL FOOTINGS DESIGNED FOR 2,500 PSF SOIL BEARING CAPACITY DIAGONAL DISTANCE DIMENSION FROM INSIDE CORNER OF FORMBOARDS AC = 71'-0" A = 58'-9' BD = 64'-6' BF = 68'-6" UIMENSIUNS AKE ROUNDED TO THE CLOSEST INCH FOUNDATION PLAN 1/4" = 1'-0" 3" V.T.R. I I i I I I I 1 i I I I I I I I I I I I I I I 2" TUB/ SH WR. 1-#5 CONC. BAR SLAB 8,. w H DETAIL 1 CONC. 2-#5 SLAB BAR - o 4" 4" K DETAIL 1 CONC. RECESS SLAB AT WALL GRADE 2-#"-I BARS -�j—��" M DETAIL' 1 N CONC. SLAB 7 S H1� DETAIL PIPE SLEEVE (DIA. LARGER THAN PIPING THRU FTG.) 3" MIN. FTG. PER DEPTH 3" MIN 3"MIN._ DETAIL C FOOTING & REBAR 1'-0 " 1 '-0" TRANSITION PIPE THRU PF FTC. DETAIL 1 2" LAV ,-'3- 3. W.C. 1 CONC. SLAB col 4 1 8"1 G, DETAIL 1 J 2" V.T.R. I I 2" SINK 3" 2" WASHER 3" CLEAN OUT(J 3" 3" MAIN I 1 TO SEWER MICHAEL C. ANDERSON 2" 1 OR SEPTIC TANK TUB/ SHWR- SCHEMATIC PLUMBING RISER MICHAEL C. ANDERSON, ARCHITECT OF RECORD /� 1(� /! FL. LIC. AR0017305 ` 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE -RESIDENTIAL (6TH EDITION) FL. LIC. AR0017305 F W 771 O MASTER PLAN REVISION 10-16-18 Q) d q o r'D N ti C�8co �I w Lo N Lo r CD N o m w w �p" ctmw U~0n —1 X Q fA -Q w 00 w 0 J it O J Co OWN LL J w m U` Z0 af`nU0 04 cM IL w J w H k=======J) PROJECT NO. 17-015-038 DATE DRAWN 8-7-18 DRAWN BY MCA CAYMAN 1763 B3 LIVING 1763 SQFT GARAGE 387 SQFT LANAI 148 SQFT ENTRY 38 SQFT TOTAL 2336 SQFT CUBIC VOLUME OF CONDITIONED SPACE _ 14.816.1 CUBIC FEET SHEET A 1■0 0 I I 23'-0" 1'-4" 15'-0" CONC. COLUMNS 1'-4 TOP +8'-0" A.F.F.—�, ■■ ■■ 1 ■ CONC. LINTEL ABV. ■ BOT. +6'-8" A.F.F� 23'-8" 14'-4" I 0 14'-2" COVERED PATIO 0 +7'-4" I 8' CLG_ HDR. HT. 8'-0" 3'-8" I --- R/S -- I Q f 0 I N CLG. N I 8' CLG. _8'_0" 8'-8" CLG. -I ■ ■ ■ ■ 0 O I rl HB I I i 9'-01, I n 13'-7 1 /2" I 14'-1 1 /4" R/S ■ 0 0 � I MASTER BEDROoN4 \ 42" H. 2X4 I COFFER I O KNEEWALL I n 8' CLG. I I FAMILY ROOM 4 VAULTED CLG. ■ _ - 2'-9 1/2" 2'- 4z' H.I i° I 2'-0" iv HDR. HT. ■ WALL 8' CLG � co P.T. 2-2X4 Z L CURB g I N O O N I xo N ' O ■ 0 Lo 4 Lo I ■ N I 10'-O" i� 3'-3'-0- I 4'-1 1 /4" 3'-0" 5'-0" 5'-7" 11'-4" ___ _ I RAISED-- - ---- 2'-3 1 /2" I RAISED 1 I BARTOP � DEN/BEDROOM #4 I BAR TOP 11 SINK W/ I ■ K) VAULTED CLG. n n 11 DISP. ■ 0i LIVING RM i i o LO to CATHEDRAL CLj j KITCHEN O _ 11 VAULTED CLG. N HDR. HT. ® I 11 \ Q (1 i 0 ■ R/S IN I `o m — _ ® R/S M I z I ■ ,n I [Luw-i � ■ N M O BREAK AST p I 0 I -5" VAULTED CLG. i_ 5' 7 3/4" 5'-4 1/4" �z 15'-� 1/4" 1 aao 9'-6 1/2" _ HDR. HDR. HT. HT. I 5 11 ■ cq BEDROOM #35'- N VAULTED CLG. 1 �� DINING ROOM � s CLG. N 1 CATHEDRAL CLG. 5 SH. W SHELF N ABV. ■ I 8'-0" = 8' CLG. _ Q N ACAl"D Kilu M.T. DRYER 0 o OO 3 V.T. W. ■�18' CL ® T-1 3/4" 18'-3 1/2- WH CTR. 7'-8" S-7 1 /2 d 0 I O 31" IN VAULTED CLG. `� +6'-8" ■ 2'-8" = z 0 a I I j� 2X4 � HDR. a 0 ;� O 1 KNEEWALL- HT. TOP +12'-11" 9 M.T. A.F.F. _ 0 i1 R/S — = 0� I I 22"x54" ■ AC 1 N x I ATTIC ACCESS COND -- 8 FACE OF GABLE — — — 4O 0 +12'-11" END TRUSS ABV. co CLG. HT. GARAGE 2X4 KNEEW L- IOP I I BOX OUT B TWEEN 8' CLG. +12'-11" A. TRUSSES A V. .F. I —I—It GARAGE RC OF ■ 6'-0" 1'- '3'- 3 4' ■ ■ G FACE OF 16"W. GABLE END 0 ARCH ^6, ABV. 1 -6" TRUSS ABOVE ■ HB BEDROOM #2 0 8' CLG. 1 0 Low I HDR. HT.O ■ ■ ■ ■ ■ ■ 6'-2" 12'-4" &'-4" 20" 38'-0" 16'-0" 19'-4" 20" FLOOR PLAN 1 /4" = 1'-0" DOOR SCHEDULE 0 SIZE PER R.O. SUPER. Q REMARKS 1 3068 W/ SIDE LIGHTS 1 EXT. DOOR MUNTINS IN SDLTS 2 8068 S.G.D. 1 EXT. DOOR 3 2868 SOLID CORE 1 GARAGE DOOR 4 2868 7 INT. DOOR 5 2068 POCKET 1 INT. DOOR 6 2468 POCKET 1 INT. DOOR 7 2668 BIFOLD 1 INT. DOOR 8 4068 BIPASS 3 INT. DOOR 9 2068 BIFOLD 1 INT. DOOR 10 16070 OVHD. DOOR 1 GARAGE DOOR 11 2868 POCKET 1 INT. DOOR WINDOW SCHEDULE 0 SIZE PER B R.O. SUPER`DG Q REMARKS A 35 SH ELLIPSE 1 MUNTINS B 25 SH 2 C 4'W. X S-4"H. GLASS BLOCK 1 D 33 SH 1 E 1/2 33 SH 1 OBSC. TEMPERED F 35 SH 1 G 3'-0"W. X S-6"H. FIXED GLASS W/ 2'-10"H. LEGS 1 1. WINDOWS, DOORS, AND GARAGE DOORS SHALL COMPLY WITH STANDARD BUILDING CODE WINDLOAD AND EMERGENCY EGRESS REQUIREMENTS. NOTES: 1. WOOD STUD SPACING_ (UNLESS OTHERWISE NOTED ON PLANS) -EXTERIOR FRAME WALLS AT 16" O.C. -INTERIOR FRAME BRG. WALLS AT 16" O.C. -INTERIOR FRAME NON-BRG. WALLS AT 24" O.C. -KITCHEN CABINET WALLS AT 16" O.C. 2. FRAME WALLS ARE DRAWN 3 1/2" WIDE UNLESS OTHERWISE NOTED 3. CONC. BLOCK WALLS ARE DRAWN 7 5/8" WIDE UNLESS OTHERWISE NOTED 4. TOOL CONC. BLOCK JOINTS INSIDE GARAGE WALLS (BRUSH & CLEAN) 5. DOOR & WINDOW ROUGH OPENINGS SHALL BE PROVIDED BY BUILDER 6. TOP OF TYP. BEARING WALL +8'-0" UNLESS OTHERWISE NOTED 7. HEIGHTS ARE MEASURED ABOVE TOP OF FOYER SLAB 8. SEE STRUCTURAL NOTES FOR ADDITIONAL INFORMATION MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE -RESIDENTIAL (6TH EDITION) MICHAEL C. ANDERSON FL. LIC. AR0017305 PLAN REVIEW REVISIONS MASTER PLAN REVISION 10-16-18 Wo F4" C�6 Iw w co O N Lo N Cl m ♦� w W co N _ _j CD J�MX i Q w1 fn -QW00 ( t J LL J FE C) co W J°o0°�°_N m<LL W 1_7 Sl) Z00<r- �`oUCNI O ace) W J W PROJECT NO. 17-015-038 DATE DRAWN 8-7-18 DRAWN BY MCA CAYMAN 1763 B3 LIVING 1763 SQFT GARAGE 387 SQFT LANAI 148 SQFT ENTRY 38 SQFT TOTAL 2336 SQFT F14,816.1 OLUME OF IONED SPACE _ CUBIC FEET SHEET (LA 2mO ATTACH 1-1/2' X 4-1/2" P.T. BUCK TO BLOCK WITH: GONG OR MASONRY HEAR: 1/4" X 3-3/4' TAPOONS SPACED 4" FROM CORNERS, Y & 6" FROM MUWON. JAMBS: 1/4' X 3-3/4' TAPCONS SPACED 4" FROM CORNERS, 18.W O.C. MAX. DRYWALL BOARD - C£IAENnTIWS FlNlSH DOOR �PFRM METER CAULKNG ATTACH DOOR FRAME TO 2X P.T. BUCK WITH: DOOR TRIM HEAD: 110 X 2-1/Y PFH WOW SCREWS SPAS 4' FROM CORNERS 3' & 6" FROM MULLION. JAMBS: JIG X 2-1/2' PFH WOW SCREWS SPACED 4" FROM CORNERS, 1&W O.C. MAX. HEAD/JAMB DETAIL (2X BUCK) EXT DOOR COW OR MASONRY ATTACH DOOR FRAME TO BLOCK WITH. HEAD: 1/4" X 3-3/4" TAPCONS SPACED 4' FROM CORNERS. 3' & 6* FROM MUWON. JAMBS: 1/4" X 3-3/4" TAPOONS SPACED 4" FROM CORNERS, 1&W D.C. MAX. — 3/4' x 4-1/2' P.T. BUCK SET IN SEALANT AND SECURED W/ CASE HARD NAILS 0 12" O.G. (MAX) PERIMERR 04OLKWG FLOOR WIEIM— �C£MENnnOUS FINS NOTES: 1. HOLD ALL WOOD FASCIA/SOFFIT 3/4" ABOVE ROOF SHEATHING. 2. WALL FENESTRATION PER FBCR 2017 703.4 3. PROVIDE FLASHING BETWEEN SLOPED ROOF AND VERTICAL WALL INTERSECTIONS, FLASHING SHOULD BE CONTINUOUS OR STEP FLASHING IN CONTINUOUS BED OF ROOFING CEMENT. 4. PROVIDE SEALANT PAINTED ON WINDOW / DOOR BLOCK WALL OPENINGS WITH 1X BUCKS ATTACHED WITH MASONRY NAILS, APPLY SEALANT OVER INSTALLED BUCKS - SEALANT TO BE SHERWIN WILLIAMS CONFLEX OR EQUIVALENT. FRAMED WINDOW OPENINGS SHALL HAVE TAPED WINDOW FLASHING - WINDOW WRAP BY WFM MANUFACTURING (SEE DTAIL ON SHEET A6.2). DOOR THRESHOLD SET IN BEAD OF CAULK AND FASTENED TO SILL WITH 1/4" DUL X 2-1/4" TAPCONS SPACED 3' FROM CORNERS, 3" & 6" FROM MULLION r o B �PONVER CAULKING Oo" SpOl 0 " 000 — DOOR TRIM-.� PERIMETER CAULKING CONCRETE SLAB HEAD/JAMB DETAIL (IX BUCK) EXT DOOR P.T. (2) 2X4 BUCK - CONNECT TO BLOCK W/ Xs7 x 3' TAPCONS (1 1/4' MIN. EMBEDMENT INTO BLOCK) PRECAST LINTEL AT TOP BLOCK COURSE TOP OF BLOCK WALL SILL DETAIL EXT DOOR REAR ELEVATION 2x4 VERT. AT EA. FACE OF ARCH W/ (3) 10d NAILS AT EA. END TOE NAILED W/(2) - 10d AT BUCK 2x4 SOLID BLOCKING (FULL WIDTH OF WALL) BTWN. PLYWD. ARCH FACES W/ (3) 10d NAILS THRU O.S.B. INTO EA. 2x4 P.T. (2) 2X4 BUCK - CONNECT TO BLOCK x 3' TAPCONS (1 1/4 MIN: 2X4 VE RT. BRACES EMBEDMENT INTO BLOCK) 1/2" COX PLYWOOD PANEL (BOTH SIDES) NAILED TO BUCK W/ Bd NAILS AT 4" O.C. PROVIDE Ns7 x 3" TAPCON (1 2x4 SOLID BLOCKING (FULL 1/4" MIN. EMBEDMENT INTO WIDTH OF WALL) BTWN. PLYWD. BLOCK) AT EA. SIDE BUCK-(1) ARCH FACES W/ (3) 10d NAILS WITHIN 4" MIN. TAPCON OF THRU O.S.B. INTO EA. 2x4 START OF ARCH J BUILT-UP PLYWOOD OR MASONITE BUCK - SCRIBE BACKSIDE TO FIT ARCH. CONNECT W/ 8d NAILS 1" x 3" BUCK CONTINUOUS SECTION A —A 1/4 = I -u 1/2' COX PLYWOOD A -A FPANEL (BOTH SIDES) NAILED TO BUCK W/ 8d NAILS AT 4" O.C. PRECAST LINTEL AT TOP BLOC( COURSE ARCH OPNG. ARCH IN MASONRY OPNG. DETAIL RIDGE HEIGHT — — — — — — — — — — — — — — — — — — — — — — — — — +1r-:10" A.F.F. BUILT-UP PLYWOOD OR MASONITE BUCK - SCRIBE BACKSIDE TO FIT ARCH. CONNECT W/ 8d NAILS LINE OF RECTANGULAR ROUGH OPENING 12 61 _ _TOP OF BLK +$'-0" A.F.F. — — TOP OF SLAB _ +0'-0" A.F.F. (REF. ELEV.) LEFT SIDE ELEVATION Ix3 OR Ix4 P.T. BUCK SET IN SEALANT AND NAILED WI-1/Y CASE HARDENED COL NAILS AT 12' O/C. MAX CONC. OR MASONRY RD LIME BUCK w/ TAPCON ' 0/C RILLED NUFACIURER JILKING FM9R HEAD DETAIL WIND❑W 00 3E X:I io op 1/4" = 1'-0" ALUMINUM FRAME FASTEN THRU BUCK W/ 3/16 x3 1/4" TAPCON SCREWS 0 24' 0/c MAX IN PREDRILLED HOLES BY MANUFACTURER PERIMETER CAULKING CEMB47777 US FW191 CONC OR MASONRY Ix3 OR Ix4 P.T. BUCK SET IN SEALANT AND NAILED W/1-1/2' CASE HARDENED COIL MAILS AT 12' O/C MAX DRYWALL BOARD CAULIONG JAMB DETAIL WIND❑W ALUMINUM FRAME SEWRE FRAME TO SILL NTH SUCONE LPRECAST OR POURED SILL PERIMETER CAULKING SILL DETAIL WIND❑W 12 16 _TOP OF BLK. TOP OF SLAT 0'-0" +A.F.F. (REF. ELEV.) — —TOP OF BLK� CEMENTITIOUS COATING 00 _ ON BLOCK 'S p 6"W. RAISED TRIM 12 (PROD. 3/4") 16 TRUSS BRNG. ENTRY 6"W. RAISED STUCCO +12'-11" A.F.F. FRIEZE TRIM (PROJ. 3/4") TOP OF WINDOW " ROOF AT 12'-6" A.F.F. 88 CRICKET I`'IL 16"OVERHANG 6"W. RAISED TRIM El El TYPICAL UNLESS (PROJ. 3/4") f OTHERWISE NOTE[ TOP OF BLOCK — — — 1 - 3'-0" -8" TOP OF +8 ----ee� ------------------ — — — — — 0 A F F �— +8'-0" ,TOP OF SLAB — +0 -0 A.F.F. (REF. ELEV.) R SMOOTH STUCCO FINISH AT co = FRONT DOOR I � - J FRONT ELEVATION 1/4" = 1'-O" ENTRY SECTION RIGHT SIDE ELEVATION 1/4" = 1'-O" 1/4" = 1'-O" STUCCO FINISH BIER CAUL OMG COMIC OR MASONRY 1x AT. BUD( SET IN SEALANS T AM NAILED W/1-1/2' CASE HA .� COL NAYS AT 24" O/C wDRYWALL BOARD DOOR FRAME FASTEN IMU BUCK W/ W/ -1-1/4' x 1/4" (MIN) TAPCONS AT 24 O/C MAX IN PREDRILL D HOES BY MANUFACTURER JAMB/HEAD DETAIL u![lnvrr (SGD) DOOR FRAME FASTEN TO SILL W/ IS x 1' SCREWS 0 2'-0- o/c lur,M;z.as�:rr:Ta n GMT BED \ `---CONCRETE SLAB SILL DETAIL (SGD) MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE -RESIDENTIAL (6TH EDITION) TOP OF SLAB +0'-0" A.F.F. (REF. ELEV.) MICHAEL C. ANDERSON FL. LIC. AR0017305 PLAN REVIEW REVISIONS MASTER PLAN REVISION 10-16-18 �I W Q O (Z) � Q E-4 co q If 44 -�) Z 4, Qti 6 C�6 �I w c� N Lo Ln CO I N O a) cw LLI O � s J ::) O " J U) M Q z c6 u-00 LL C) J O �; —i m O GO N a.. LLI�COO U' ZOQ�(� ruU)� I-W U) U) z I- = c+) d LLI J W PROJECT NO. 17-015-038 DATE DRAWN 8-7-18 DRAWN BY MCA CAYMAN 1763 B3 LIVING 1763 SQFT GARAGE 387 SQFT LANAI 148 SQFT ENTRY 38 SQFT TOTAL 2336 SQFT CUBIC VOLUME OF CONDITIONED SPACE _ 14.816.1 CUBIC FEET SHEET A 3.0 HATCHED AREA INDICATES 2x4 BOTTOM CHORD BLKG. AT 48" O.C. SEE NOTE #2---___� l'-4" - OH 0 - OH 1/2"0 A.B. AT 32" O.C. IN LINTEL I X1 I I B-10 SEE GABLE END SECTION XX SHEET A6.1 B-8 No B-s I i B-7 I if 8 FLAT CLG. II I 11 2 "X" BRACING 11 TYP_ II I i 8' FLAT I COFFER CLG. CLG. I VAULTED CLG. OH VAULTED CLG. II II VAULTED CLG. I I 1 1 VAULTED CLG. I I B-4 I I I I CATHEDRAL CLG. 8' FLAT CLG. I 8' FLAT CLG. VAULTED CLG. 8' FLAT CLG. OH (2)2x6 2x4 "X" BRACING TYP. I I i x 22"x54" ATTIC ACCESS 2X4 KNEEWALL- TOP + 12'-11" A.F.F. II II 2X4 KNEEWALL- TOP + 12'-11" A.F.F. 8' FLAT CLG. LL ` I II II JJ II 10 II II II I II II I I 16" II II II I it II II II I I B-2 1/2"0 A.B. AT 32" O.C. IN LINTEL �o B-, 1/2"0 A.B. AT 32" O.C. IN LINTEL SEE SECTION X-X ON SHEET A6.1 x4 "X" BRACING TYP. 'ROVIDE 2x4 30TTOM CHORD ILKG. AT 48" ).C. SEE NOTE #2 ANCHOR SCHEDULE (SIMPSON STRONG -TIE PRODUCTS MODEL NUMBER) DESIGNATION MODEL # ALLOWABLE LOADS NAIL PATTERN SIMPSON HETA20 < 1810 > 10-10d x 1 1/2 USE SIMPSON HETA20 FOR ALL TRUSS TO BLOCK CONNECTIONS (U.N.O.) SIMPSON MTS12 < 1000 > 14-10d x 1 1/2 USE SIMPSON MTS12 FOR ALL TRUSS TO FRAME CONNECTIONS (U.N.O.) SIMPSON (2) HTS20 < 2900 > 24-10d X 1 1/2 TO PLATES 24-1Od X 1 1/2 TO STUDS CONNECTOR PER ANCHOR SCHEDULE 2-2X4 TOP PLATE W/ SIMPSON "SPH4" AT EACH TOP PLATE / STUD CONN. KNEEWALL W/ 2X4' SPACED 16" O.C. 2 X 6 BETWEEN TRUSSES UNDER FRAME WALL SIMPSON "SPH4" AT ALL BOT. PLATE/STUD CONN. FRAMING PLAN 1/4" = l'-0" PRECAST HEADER SCHEDULE B-X 71 LINTEL CAST CRETE ALLOWABLE ALLOWABLE MEMBER LENGTH TYPE LOAD UPLIFT B-1 208" 8F16-1B 950 PLF 361 PLF B-2 70" BF8-1B 1459 PLF 1272 PLF B-3 42" 8F16-lB 6113 PLF 3547 PLF B-4 64" 8F16-1B 5365 PLF 2290 PLF B-5 54" 8F16-lB 6039 PLF 2507 PLF B-6 70" 8F16-16 1459 PLF 1272 PLF B-7 112" 8F16-lB 1818 PLF 980 PLF B-8 64" 8F16-lB 5365 PLF 2290 PLF B-9 64" 8F16-lB 5365 PLF 2290 PLF B-10 168" 8F16-1B 1002 PLF 559 PLF 12 PER CONNECTOR PER ELEV. ANCHOR SCHEDULE ROOF TRUSS OVER ENTRY +13'-2" STD. BRG. HT. DBL. 2x4 TOP PLATE PLACE 2 X 4 STUDS OVER EACH TRUSS (2'-0" O.C.) 7/16" O.S.B. 8d ® 4" O.C. EDGES 6" O.C. FIELD CONNECTOR PER FRAMING PLAN P.T. 2X4 BOT. PLATE W/ 1/2- DIA. A.B. ® 16" O.C. W/ 2-3/4" MIN. EMBED. & 2" SQ. WASHERS KNEEWALL DETAIL 3-16d NAILS 2 X 4 VALLEY FRAMING AT 16" O.C. REFER TO TRUSS ENGINEERING FOR CUPPED GARAGE TRUSS FRAMING NOTES: 1. DESIGN LOADS: WIND: 160 M.P.H. AT 3 SECOND BURST ROOF: 37 PSF (20 LL/17 D.L.) 2. #2 OR BETTER 2x4 BLOCKING AT 4'-0" O.C. WITH 2 EA. 16d TOE NAILED EACH SIDE (DIAPHRAM AREA) 3. AT BLOCK/STRUCTURAL FRAME WALL CONNECTION, PROVIDE 1/2" DIA. COUNTERSUNK ANCHOR BOLTS W/ 2-1/4" MIN. EMBED. ® 24" O.C. VERT ® (2)2x4 P.T. VERT, 4. SEE FRAMING PLAN FOR PRECAST LINTELS TYPICAL 5. PERMANENT OR TEMPORARY BRACING OF TRUSSES PER HIB91. ANY ADDITIONAL TRUSS BRACING REQUIRED WILL BE DETERMINED BY TRUSS ENGINEER ON SIGNED AND SEALED TRUSS DIAGRAMS. 6_ ALL HEIGHTS NOTED ON PLANS ARE MEASURED FROM TOP OF FINISH FLOOR (REF. ELEV. 0'-0") 7. ALL TRUSS TO TRUSS CONNECTORS TO BE SUPPLIED BY TRUSS MANUFACTURER. 8. SEE STRUCTURAL NOTES FOR ADDITIONAL INFORMATION. 9. OVERHANG IS V-4" UNLESS NOTED OTHERWISE MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE -RESIDENTIAL (6TH EDITION) MICHAEL C. ANDERSON to//?/l c� FL. LIC. AR0017305 F EW REVISIONS MASTER PLAN REVISION 10-16-18 Q) o W Q q q I� �f- W ti 46 �I w co O Lo rn �- N O � W co i J n � X w U) M Q Q V- co 1 p M 0 C) co JmOr-N J , �w�mC9 ZOQU af Lo co Z C U2 cM 0- W J W H PROJECT NO. 17-015-038 DATE DRAWN 8-7-18 DRAWN BY MCA CAYMAN 1763 B3 LIVING 1763 SQFT GARAGE 387 SQFT LANAI 148 SQFT ENTRY 38 SQFT TOTAL 2336 SQFT CUBIC VOLUME OF CONDITIONED SPACE _ 14,816.1 CUBIC FEET SHEET A 4mO -OR VE COACH LTS. PREWIRE FEEDER 120/24OV-1PH-3W MAIN BREAKER MAIN LUG ONLY AMPS 150 AMP BUS AMPS 200 A/C 22,000 INT A/C 65,000 CIRCUIT NO. CIRCUIT ID BRK AMP WIRE SIZE A PHASE A PHASE WIRE SIZE BRK AMP CIRCUIT ID CIRCUIT NO. 1 A/C 40 8 6 60 HEAT 2 3 A/C 40 8 6 60 HEAT 4 5 DRYER 30 10 8 40 RANGE 6 7 DRYER 30 10 8 40 RANGE 8 9 REFRIDG 20 12 12 20 WASHER 10 11 KITCHEN 20 12 12 20 BATH GFI 12 13 KITCHEN 20 12 14 15 BEDROOM ARC 14 15 H-W 30 10 14 15 BEDROOM ARC 16 17 H-W 30 10 14 15 GENERAL LITE 18 19 SPACE 14 15 BEDROOM ARC 20 21 GENERAL LITE 15 14 14 15 WP/GARAGE GFI 22 23 DISHWASHER 20 12 14 15 GARAGE DOOR 24 25 14 15 GENERAL LITE 26 27 14 15 GENERAL LITE 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 ELECTRICAL LOAD CALCULATION 2074 S.F. AT 3 VA 2 SMALL APPLICANCE CIRCUITS 1500 VA EACH LAUNDRY CIRCUIT RANGE 1 WATER HEATER DISHWASHER DISPOSAL DRYER SUBTOTAL FIRST 10 kVA AT 100% REMAINDER AT 40% TOTAL OF OTHER LOAD 10 kVA OF AC AT 40% TOTAL 23,480 VA DIVIDED BY 240 V POOL SUB PANEL TOTAL USE 150 AMP SERVICE EXTENT OF AREA FOR VINYL OR TILE PER CONTRACT ELECTRICAL PLAN 1/4" = 1'-0" 6.2 kVA 3.0 kVA 1.5 kVA 12.0 kVA 3.0 kVA 1.5 kVA 1.5 kVA 5.0 kVA 33.7 kVA 3 #1 CU THHN OR AL. EQUIVALENT 2" CONDUIT 150 30 CKT PANEL 0 150 METE( M.C.B. 10.00 kVA 2" RIGID O.H. SERVICE F.P.L. 9.48 kVA 19.48 kVA 4,00 kVA 23.48 kVA NO. 4 CU. WIRE 97.8 A TO UFER GRIND. 30.0 A 127.8 A SCHEMATIC ELECTRICAL RISER BACK TO BACK SERVICE ELECTRICAL NOTES 1. ALL BEDROOMS SHALL HAVE AFCI CIRCUIT PROTECTION UNLESS NOTED OTHERWISE. 2_ ALL COUNTERTOP KITCHEN AND BATHROOM OUTLETS SHALL BE GFI CIRCUIT PROTECTION UNLESS NOTED OTHERWISE. 3. ALL EXTERIOR OUTLETS SHALL BE WATER PROOF GFI CIRCUIT PROTECTION UNLESS NOTED OTHERWISE. 4. PROVIDE DISCONNECTS AT ALL APPLIANCES AND OTHER EQUIPMENT AS REQUIRED BY N.E.C. 5. IF NE BRANCH CIRCUITS ARE ADDED: A) ALL 120V, SINGLE PHASE, 15 & 20 A BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT (NEC 210.12 (B)). B) TAMPER RESISTANT RECEPTACLES (NEC 406.11) ARE REQUIRED IN DWELLING UNITS IN ALL AREAS AS SPECIFIED IN 2008 NEC 210.52, ALL 125V, 15 & 20A RECEPTACLES. NOTE: ELECTRICAL PLAN IS SCHEMATIC. ELECTRICIAN SHALL VERIFY THAT ALL ELECTRICAL INSTALLATIONS MEET APPLICABLE VERSION OF NATIONAL ELECTRICAL CODE AND 2017 F.B.C. LEGEND SURFACE MTD. CEILING FIXTURE PENDANT FIXTURE RECESSED LIGHT WALL MTD. BRACKET @ 72' A.F.F. FLUORESCENT FIXTURE LL fti WALL MTD. VANITY LIGHT ® EXHAUST FAN EXHAUST FAN W/ LIGHT EXTERIOR FLOODLIGHTS CEILING PADDLE FAN (PREWIRE OR W/ LIGHT AS NOTED) J WALL MTD. SMOKE DETECTOR jl O CEILING MTD. SMOKE DETECTOR CEILING MTD. CARBON MONOXIDE DETECTOR -� CHIMES -0 CHIMES PUSH BUTTON TELEPHONE JACK CABLE TELEVISION JACK 110 V. DUPLEX RECEPTACLE 1/2 SWITCHED 110 V. DUPLEX RECEPTACLE 110 V. GFI DUPLEX RECEPTACLE 220 V. RECEPTACLE H% DE➢ICATED 220 V. OUTLET 110 V. JUNCTION BOX - SWITCH @ 42' A.F.F. o- RHEOSTAT SWITCH @ 42' A.F.F. TP TOUCH PAD FOR SECURITY SYSTEM O CENTRAL VACUUM OUTLET LOCATION L= ELECTRICAL DISCONNECT MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE -RESIDENTIAL (6TH EC MICHAEL C. ANDERSON `6l 12w �l FL. LIC. AR0017305 PLAN REVIEW REVISIONS MASTER PLAN REVISION 10-16-18 Lo 41 � �� W Q q (� O N ti C�6 gal w W co co r� rn Cl N ctw W N 0 U~�I,- 16 M X z (n ' Q CLL pp W 04 0 _ o Jm000 w � (oU` z0<r- BE Lo CD Z (V O c) CL W J W PROJECT NO. 17-015-038 DATE DRAWN 8-7-18 DRAWN BY MCA CAYMAN 1763 B3 LIVING 1763 SQFT GARAGE 387 SQFT LANAI 148 SQFT ENTRY 38 SQFT "CUBIC _ SHEET A 5mO NOTE: ROOF UNDERLAYMENT SHALL COMPLY WITH SECTION R905 OF THE FLORIDA BUILDING CODE (6TH EDITION) 12 PER ELEV. R-30 INSULATION 1/2- CLG. GYP. BD. 8"x8" U-BLOCK TIE -BM. FILLED W/ CONC. & (1) #5 REBAR CON- PRE-ENG'RED PRECAST LINTEL SEE SHEET A 4.0 FOR DETAILS NOTE: 1x4 P.T. SCREWS FOR DRYWALL ON WALLS: MAX. EDGE SPACING: 7" PLOYCEL SEALANT MAX. FIELD SPACING: 16" SCREWS FOR DRYWALL ON CEILING: P.T. WOOD BUCK MAX. EDGE SPACING: 7" MAX. FIELD SPACING: 12" ALUMINUM WINDOW (REFER TO FLOOR PLAN FOR SCHEDULE) MARBLE SILL 1/2" DRYWALL ON 1x2 P.T. FURRING ® 16" O.C. R-4.2 FOIL INSULATION W/ 4 MIL VAPOR BARRIER - 4" 2500 PSI CONIC. SLAB W/ FIBER WD. BASE - MESH, ON 6 MIL. POLY VAPOR BARRIER OVER TERMITE TREATED CLEAN FILL COMPACTED TO A MINIMUM DENSITY OF 95% AS DETERMINED BT ASTM D-1557 ARCHITECTURAL FIBERGLASS SHINGLES OVER 30# FELT ON 15/32" CDX PLYWOOD SHEATHING AND PRE-ENGINEERED WOOD ROOF TRUSSES AT 24" O.C. (SEE ROOF NAILING PATTERN DETAIL) - HURR. STRAP ® EACH TRUSS REFER TO CONNECTOR SCHED. TYP. O.H. ROOF PLAN. _--TOP_OF_BLOCK ' REFER TO EXT. ELEV. ALUM. FASCIA AND DRIP EDGE UNLESS OTHERWISE NOTED ON EXT. ELEV. CONT. ALUM. VENTED SOFFIT WDW HDR. H_T. PER PLANS RAISED CEMENTITIOUS TRIM PER ELEV. PER PLANS RAISED CEMENTITIOUS TRIM PER ELEV. PER PLANS 5/8" MIN. CEMENTITIOUS COATING OVER 8x8x16 CONC. BLOCK 1-#5 VERT. BAR TIED INTO #5 BAR DOWEL W/ STD HOOK AND RUNNING INTO LINTEL (LOCATIONS PER FDTN. PLAN) __0 -0" _ - _CTOP OF SLAB FINAL GRADE STUCCO STOP AS REQ'D. PER LOCAL BLDG. DEPT. -CONC. FTG. PER FOUNDATION PLAN TYP. EXT. BLOCK WALL #_�� II I I I I I CONIC BLOCK I LTa I I I I I I I I I I - ----- EXTERIOR FRAME WALL TO LINTEL 2x4 STUDS ®SPACING PER PLANS VERTICAL FILLED CELL W/ 1-#5 BAR (2) 16d a� i n r WALL (2)2x4 P.T. W/1/2" DIA. COUNTERSUNK BOLTS ® 24" O.C. VERT 2 1 f4" MIN EMBEDMENT WITH 2" SQUARE X 1/8" THICK HURRICANE WASHER TOP OF SLAB CONC. BLOCK WALL CONNECTION REINFORCED/FlLLED CONC. BLOCK CELL 1/2" DIA L-BOLT -TT (8" LONG) W/ 2" WASHER AT 32" O.C. MAX. 2x6 P.T. JAMB DETAIL 2x4 P.T. W/ CONC. �2x6 P.T. FROM BOT. OF NAIL) Al IL UJI. MUM IV ULU. UNL iD EQUAL EQUAL :x6 '.T. 1/2" DIA L-BOLT 2xi `"I (8" LONG) W/ 2" P.1 WASHER AT 32" O.C. MAX. GARAGE DOOR OPENING N ELEVATION GARAGE DOOR DETAIL i n U e u II -(2) 1Od ® 6" O.C. 3 1 /4" DETAIL AT 90" CORNER GROUT SOLID TOP OF CELL SAWCUT APPR OPENING IN W. SAWCUT APPR OPENING IN W, 25" MIN. LAP STRUCTURAL NOTES: 1. WIND LOAD REQUIREMENTS AT 160 MPH PEAK WIND GUST FOR 3 SEC. BURST PER FBCR 2017 (6TH EDITION). 2. WINDOWS, DOORS, AND GARAGE DOORS SHALL BE DESIGNED TO THE 2017 FLORIDA BUILDING CODE. 3. ALL FLOOR SLABS TO BE OF 2500 PSI CONCRETE PLANT MIX 4" THICK WITH FIBER MESH AND/OR 6 X 6-10/10 W.W.M. W/ MIN. 1" COVER ON 6 MIL POLY VAPOR BARRIER OVER COMPACTED CLEAN FILL. 4. FIBER MESH REINFORCEMENT: FIBERS SHALL BE 1/2" TO 3/4" COLLATED POLYPROPYLENE FIBERS. REQUIRED DOSAGE RATE SHALL BE AS SPECIFIED BY THE MANUFACTURER. FIBERS SHALL BE USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITHIN TIME AS SPECIFIED IN "ASTM C94'. THE FIBERS SHALL COMPLY WITH ASTM DESIGNATION C1116 TYPE 111 4.1.3 AND WITH APPLICABLE BUILDING CODES. CERTIFICATION OF COMPLIANCE SHALL BE MADE AVAILABLE ON REQUEST. STANDARD ACI 302 PROCEDURES FOR PLACING, FINISHING, AND CURING SHALL BE FOLLOWED WHEN USING FIBER MESH CONCRETE. 5. CONCRETE MASONRY UNITS SHALL MEET ASTM C90. 6. MORTAR TO BE TYPE 'M' OR 'S': GROUT TO BE 3000 PSI AT 28 DAYS. FOLLOW GROUT CONFINEMENT PROCEDURES AS DEFINED IN ACI 53-99. f'm = 1500 psi B. REBAR TO BE SIZE #5 GRADE 40, CONT. TOP OF FILL CELLS AND CHANGES OF DIRECTION WITH MINIMUM LAP OF 30". 9. OMIT 10. UPLIFT CONNECTORS TO PROVIDE CONTINUITY FROM ROOF TRUSSES THRU PLATES TO SLAB AND FOUNDATION PER ENCLOSED DETAILS. 11. EPDXY ANCHOR ALTERNATE: THREADED ANCHOR ROD MAY BE USED IN LIEU OF ANCHOR BOLTS FOR USE AS PLATE ANCHORS OR HURRICANE ANCHORS. THE FOLLOWING CRITERIA MUST BE MET: ANCHOR SIZE CONC. HOLE SIZE MIN. HOLE DEPTH 1/2" 3/4" 5/8„ 7/8" 6" 3/4" 1 7" 7/8 1 1 /B . 8" AFTER HOLE IS DRILLED ALL CONCRETE DUST MUST BE R90VED PRIOR TO EPDXY INSTALLATION. THREADED ROD (MIN. A36 STEEL) AND REBAR TO BE FREE OF DIRT OR GREASE. LOAD ON ROD OR REBAR CANNOT OR BE APPLIED UNTIL 12 HOURS AFTER APPLICATION. TWO COMPONENT EPDXY RESIN MATERIAL TO BE MIXED PER MFG. DIRECTIONS. 12. MISSING DOWEL PLACEMENT- NEW HOLE SHALL BE DRILLED 7/8" TO 1" WIDE AND 10" DEEP. AFTER HOLE IS DRILLED ALL CONCRETE DUST MUST BE REMOVED PRIOR TO EPDXY INSTALLATION. THREADED ROD (MIN. A36 STEEL) AND REBAR TO BE FREE OF DIRT OR GREASE. LOAD ON ROD OR REBAR CANNOT OR BE APPLIED UNTIL 12 HOURS AFTER APPLICATION. TWO COMPONENT EPDXY RESIN MATERIAL TO BE MIXED PER MFG. DIRECTIONS. 0 -w 6" DEEP HOLE FOR _T IN EPDXY ADHESIVE BLOCK WALL 25" MIN. LAP OF REBARS 3,000 PSI CONCRETE FILLED CELL W/ #5 BAR SAWCUT 1"W. OPENING IN WALL FROM TOP TO BOTTOM FOR FULL HEIGHT REBAR PLACEMENT INTO CELL - FILL SOLID W. CONCRETE X 6" DEEP HOLE FOR w #5 BAR SET IN EPDXY ADHESIVE ADDED REINF. FILLED BLOCK CELL DETAIL NOTES: -DRILLED HOLE TO BE CLEANED PRIOR TO DISPENSING ADHESIVE -EPDXY ADHESIVE TO BE HIGH STRENGTH TYPE -REBAR DOWEL TO BE CLEAN AND OIL FREE WOOD STRUCTURAL NOTES: 1. ALL WOOD TO BE SPECIES, GROUP, AND GRADE AS SHOWN ON DETAILS. DAMAGED WOOD NOT TO BE USED. 2. GROUP II WOOD IS SOUTHERN YELLOW PINE #2. Fb=1200 PSI, E=1,600,000 PSI, M.C.=19% MAX.,TYP. PINE GROUP III WOOD IS DOUGLAS FIR -LARCH, SOUTHERN YELLOW PINE, HEM -FIR, OR SPRUCE -PINE -FIR, 3. ROOF TRUSSES TO BE SET WITHIN 5" OF STUD LOCATED BELOW. 4. END JOINTS IN STRUCTURAL DOUBLE TOP PLATE SHALL BE OFFSET AT LEAST 4'. STRUCTURAL DOUBLE PLATES TO BE NAILED AT 6" O.C- MAX. 5. EXT. SHEATHING ON WALLS TO BE MIN. 15/32" CDX PLYWOOD. WALL NAIL PATTERN TO BE 6" O.C. W/ 10d NAILS UNLESS OTHERWISE NOTED. 6. ALL STRUCTURAL LUMBER (EXCLUDING PREENG. WD. TRUSSES) TO BE #2 OR BETTER GROUP 11, UNLESS OTHERWISE NOTED. 7. STRUCTURAL HEADER SIZES SHOWN ON ROOF FRAMING PLAN ARE TO BE #2 OR BETTER, SPECIES GROUP II 8. MAX. 1" HOLE DRILLED INTO EXTERIOR STRUCTURAL STUDS. 9. STUDS TO BE DOUBLED AT EACH END OF SHEARWALL AS PER DRAWINGS. 10. WHEN ANCHORING (2) WOOD ITEMS TOGETHER, THE LENGTH OF HURRICANE STRAP MUST BE EQUALLY HALF ON EA. ITEM_ 11. NAIL PATTERNS: -DOUBLE PLATE AT 12" O.C. OUTSIDE THE SPLICE ZONE (SEE NOTE #4). -DOUBLE STUD NAIL PATTERN AT 12" O.C. -DOUBLE HEADER NAIL PATTERN AT 6" O.C. AT EA. EDGE, 12" O.C. INTERNALLY. -HEADER TO STUD- 4" O.C. EA. HEADER MEMBER -STUD TO TOP OR BOTTOM PLATE- (2)16d END NAILED OR (2)16d TOE NAILED EA. SIDE -ALL INTERIOR HEADERS TO BE (2) 2x WITH 1/2" FLITCH GLUED AND NAILED WITH 16d AT 8" O.C. STAGGERED. 12. ROOF SHEATHING TO BE MIN. 15/32" COX PLWOOD NAILED PER ROOF NAILING PATTERN DIAGRAM. 13- ALL NAILING SPECIFIED TO BE APPLIED BY NAIL GUN AND/OR MANUALY. 14. TRUSS BRACING PER TRUSS MFG. DRAWINGS. 15. AT ALL INTERIOR WALLS THAT ARE NOT LOAD BEARING, METAL STUDS MAY BE SUBSTITUTED FOR WOOD STUDS. 16. ANCHOR BOLTS 8" LONG x 1/2" DIA. WITH A 2" SQUARE X 1/8" THICK HURRICANE WASHER EMBEDDED 5" UNLESS NOTED OTHERWISE. 17. ALL EXTERIOR CEILING MATERIAL TO BE 1/2" MIN. EXTERIOR GRADE GYP. BOARD OR 1/2" MIN. SOFFIT BOARD UNLESS NOTED ALL PLANS, DETAILS, AND NOTES ON THESE DRAWING ARE PROPRIETARY AND CANNOT BE USED, TRANSFERED, OR OTHERWISE REPRODUCED WITHOUT THE APPROVAL OF RENAR HOMES OROOF EDGE J O I d - - - - - - - - - - - -- y�A lO O i O ROOF EDGE 2 I 1 2o RIDGE -4 1 ' -----0 01 � z 2 --{ - It lO ZONE 1-USE 8d RING SHANK NAILS ® 6" O.C. O ZONE 2-USE ad RING SHANK NAILS O ZONE 3-USE 8d RING SHANK NAILS ® 6" O.C. ® 4" O.C. NAILING PATTERN FOR ROOF ROOF SHAPE REPRESENTS TYPICAL ZONES ONLY. MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. UC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE -RESIDENTIAL (6TH EDITION) MICHAEL C. ANDERSON FL. LIC. AR0017305 PLAN REVIEW REVISIONS MASTER PLAN REVISION 10-16-18 LID Lo m N o m �w W co n o _�vX w M Q LL 0 LL N 1 p J ii o m W J in O N J r LL W c00 z < f- � ul r = cn a w J W PROJECT NO. 17-015-038 DATE DRAWN 8-7-18 DRAWN BY MCA CAYMAN 1763 B3 LIVING 1763 SQFT GARAGE 387 SQFT LANAI 148 SQFT ENTRY 38 SQFT TOTAL 2336 SQFT CUBIC VOLUME OF CONDITIONED SPACE _ 14.816.1 CUBIC FEET SHEET A 6mO INSTALL SIMPSON HTSM16 W/ (8) 10d NAILS TO TRUSS ATTACH STRAP TO LINTEL W/ (4) 1/4" x 2-1/4- MIN TAPCONS VERIFY NUMBER OF TAPCONS WITH CONNECTOR SCHEDULE 8" X 8" X 16" — CONCRETE LINTEL BLOCK FILL WITH CONCRETE AND (1) #5 BAR ALTERNATE TRUSS ANCHOR DETAIL N.T.S. LINTEL BLOCK TOP COURSE FILLED W/ GONG. & 1-#5 1 Z Z o�_< U) C.)a ZWK TOP OF LOWER i = a BLOCK WALL F- #5 BAR DOWEL W/ STD. 90- HOOK 2x6 RAFTERS AT 24" O.C. MAX. 2x4 VERT. STUDS ® 4'-0" O.C. (PLACE ABOVE TRUSS BELOW) PRE-ENG'RED SEE TRUSSES NOTE #4 NOTES: 1. HURRICANE CONNECTORS REQ'D AT 8'-0" O.C. 2. PROVIDE "H2.5" OR "LSTA18" AT EACH RAFTER END 3. PROVIDE 2x8 RIDGE BOARD WHEN APPLICABLE 4. PROVIDE 2x4 VALLEY BLOCKING BTWN. TRUSSES AT LOCATIONS WHERE VALLEY FRAMING DOES NOT BEAR ABOVE TRUSS TOP OF HIGHER BLOCK WALL #5 BAR DOWEL W/ STD. 90' HOOK VERTICAL FILLED CELL W/ 1-#5 BAR BLOCK WALL HEIGHT TRANSITION DETAIL EL 36" ABOVE ADJACENT FLOOR 5x5xf" WELDED FLANGE ALCOA TRADITIONAL "F" CHANNEL W/ 5/8" CASEHARD "STUB" OR "T" NAILS 1 p I d1NAILSC®INOCOD.C: IN WOOD R NTH PRE-ENGINEERED 1" 1" 3" 0 x 1/4" ROOF TRUSS STEEL PIPE L 2X2 NAILED TO EVERY ®" TAPCON OTHER TRUSS TAIL W/ TYP.4 U r� (2)-10d NAILS 5x5xX' WELDED CONCRETE "U" BLOCK FLANGE TIE -BEAM TOP COURSE 1 _ HORIZ. 2X2 NAILED TO BOLLARD DETAIL VERT 2X2S w/ (2)-10d NAILS ALUM. NAILS 0.12 DIA. SHANK 3/8" DIA HEAD 1-1/2" LONG ® 6" O.C. ALUM. NAILS 0.12 DIA_ SHANK 3/8" DIA HEAD 1-1/2" LONG - (2) PER SOFFIT SEGMENT "ALCOA TRADITIONAL VENTED SOFFIT DETAIL ALUMINUM SOFFIT #V-144 N.T.S. ROOF STEEL, N SHEATHING OR WOO1 SIMPSON STRONG -TIE PANEL 'H2.5' OR 'LSTA18' AT EA. END OF 2x4 ANCHOR'. VERT. STUD NOTE #4 HAND FRAME VALLEY DETAIL THIS DETAIL APPLIES ONLY WHEN AN INDIVIDUAL 2x6 RAFTER HORIZONTAL SPAN IS GREATER THAN 8'-0" O.S.B. SHEATHING OVER WOOD TRUSSES STUCCO FINISH ON METAL LATH BOND BREAK (2) LAYERS 15# FELT MEMBRANE BRIDGE FLASHING FLASHING / CONTROL JOINT STUCCO FINISH ON BLOCK FLASHING DETAIL AT ROOF FRAMING ON MASONRY ROOF SHEATHING EXPANSK STRIP & ® JAMB HEAD LO (ONLY) MORTAR JOINTS 1/4" TO 3/8" (TYPICAL) 8"X8"X4" (NOMINAL SIZE) GLASS BLOCK UNITS PANEL ANCHORS & REINFORCEMENT EVERY OTHER COURSE OR 16" 0_C. WHICHEVER IS LESS ASPHALT EMULSION THIN MORTAR SILL LOCATION GLASS BLOCK UNITS: 8" X 8" X 4" (NOMINAL SIZE) MORTAR: TYPE "S" PER ASTM C 270. REINFORCEMENT: LADDER TYPE, 9—GAUGE, 2" WIDE WITH BUTT —WELDED CROSS WIRES AT 16" O.C., HOTT DIPPED GALVANIZED. PANEL ANCHORS: 20 GAUGE PERFORATED STRIPS, 24" X 1 3/4", HOT —DIPPED GALVANIZED, AT BOTH JAMB AND HEAD LOCATIONS ANCHORED WITH #10 X 1 1/4" LONG PANHEAD SCREWS WITH #10 WASHERS (2 PER PANEL ANCHOR) OR (1)3/16" X 1 1/4" HILT] KWIK BOLT II. EXPANSION MATERIAL: 3/8" THICK POLYETHYLENE TYPE. SEALANT: SILICONE TYPE. GLASS BLOCK INSTALLATION USE SIX GALVANIZED 11 OR 12 GAUGE ROOFING NAILS WITH HEADS AT LEAST 3/8" IN DIAMETER. ALL NAILS MUST BE DRIVEN FLUSH WITH THE SHINGLE SURFACE AND PENETRATE THROUGH THE WOOD DECK BY AT LEAST 1/8" PLACE NAILS 6-1/8" FROM BOTTOM EDGE OF EACH SHINGLE AND 1" FROM EACH END. USE 6 NAILS PER SHINGLE ALL NAILS TO BE PLACED ON 6-1/8" NAIL LINE SHINGLE SIDE VIEW SHINGLE NAILING DETAIL HIGH WIND OR STEEP SLOPE N.T.S. MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE -RESIDENTIAL (6TH EDI MICHAEL C. ANDERSON tad/TI /a FL. LIC. AR0017305 PLAN REVIEW REVISIONS MASTER PLAN REVISION 10-16-18 Lo O � � Q C() q 4d IW CYD O 0 C) N o 0') w Ill CD N �� U H rn $ 55 M X z Q w1 uS QLLcli � 0 —1 C) co Jm0r—N J LL W c0(9 z0Qn� `n co O r 2 ch O_ UJ J W F PROJECT NO. 17-015-038 DATE DRAWN 8-7-18 DRAWN BY MCA CAYMAN 1763 B3 LIVING 1763 SQFT GARAGE 387 SQFT LANAI 148 SQFT ENTRY 38 SQFT TOTAL 2336 SQFT CUBIC VOLUME OF CONDITIONED SPACE _ 14,816.1 CUBIC FEET SHEET A6ml CORNER_` ^ \� FLASHING TAPE VVV CORNER FLASHING TAPE FLASHING TAPE SIDE FLASI TAPE FIN CORNER WINDOW TOP NAILING 12111111=010I•IM WINDOW BOTTOM SILL FLA SIL 1. CUT THE WATER RESITIVE BARRIER (1C)ATER RESISTIVE BARRIERI I 19ST CUT I I ITH CUT, I I I I MAKE A 6" CUT UP I I �3R91 I FROM EACH TOP I I CUTI I CORNER AT A 450 I I 1 ANGLE TO ALLOW THE I I 450I WATER BARRIER TO I I �� I I BE LAPPED OVER THE I FIN AT THE j j/-�2ND�- I I THE WINDOW. HEAD OF OL�_ CUT _�SI L— — — — — — — — — — — — J 2. FOLD THE WATER RESISTIVE BARRIER (11)). FOLD SIDE AND BOTTOM FLAPS INTO THE OPENING AND STAPLE TO INSIDE WALL FOLD TOP FLAP UP AND TEMPORARILY FASTEN 3. APPLY SILL FLASHING TAPE #1. CUT A PIECE OF FLASHING TAPE 12" LONGER THAN THE OPENING WIDTH. APPLY AT THE BOTTOM OF THE OPENING AS SHOWN (1E) SO IT OVERHANGS i" TO THE EXTERIOR. NOTE: THE TAPE IS CUT 12" LONGER THAN THE WIDTH SO THAT IT WILL EXTEND 6" UP EACH SIDE OF THE OPENING. 4. TAB THE SILL FLASHING TAPE AND FOLD. CUT 1" WIDE TABS AT EACH CORNER (V FROM EACH SIDE OF CORNER) (1F) FOLD TAPE TO THE EXTERIOR AND PRESS FIRMLY TO ADHERE IT TO THE WATER RESISTIVE BARRIER. 5. APPLY SILL FLASHING TAPE #2. CUT A PIECE OF FLASHING TAPE 12" LONGER THAN THE OPENING WIDTH. APPLY AT THE BOTTOM, OVERLAPPING TAPE #1 BY AT LEAST 1". DO NOT ALLOW THE TAPE TO EXTEND PAST THE INTERIOR FACE OF THE FRAMING (1G). NOTE: THE FLASHING MAY NOT FULL COVER THE FRAMING MEMBERS. 1. APPLY SIDE FLASHING TAPE. CUT TWO PIECES OF FLASHING TAPE 4' LONGER THAN THE FRAME HEIGHT OF THE WINDOW. APPLY ONE PIECE TO EACH SIDE OVER THE NAILING FIN AND ONTO THE WATER RESITIVE BARRIER. THE TAPE SHOULD EXTEND 2" ABOVE THE TOP OF THE WINDOW AND 2" BELOW THE BOTTOM OF THE WINDOW. PRESS THE TAPE DOWN FIRMLY. I 2. APPLY TOP FLASHING TAPE. CUT A PIECE OF FLASHING TAPE LONG ENOUGH TO GO ACROSS THE TOP OF THE WINDOW AND EXTEND AT LEAST 1" PAST THE SIDE FLASHING TAPE ON BOTH SIDES. APPLY THE TAPE OVER THE TOP NAILING FIN AS SHOWN. NOT" DO NOT TAPE OR SEAL THE BOTTOM NAILING FIN. 3. FOLD DOWN TOP FLAP OF WATER RESISTIVE BARRIER (3C) 4. APPLY FLASHING TAPE TO DIAGONAL CUTS. CUT PIECES OF FLASHING TAPE AT LEAST 1" LONGER THAN THE DIAGONAL CUTS IN THE WATER RESISTIVE BARRIER. APPLY THE TAPE COVERING THE ENTIRE DIAGONAL CUT IN THE WATER RESISTIVE BARRIER AT BOTH UPPER CORNERS OF THE WINDOW. NOTE: BE SURE TO OVERLAP THE TOP CORNERS (3D) l I � � I I I I I I I I. ROOF SHEATHING 2x4 BLKG. ® 48" O.C. ALUM. FASCIA & DRIP EDGE (2) 16d COMMON NAILS AT EA. 2X4 LADDER FRAMING GABLE END TRUSS AIR -INFILTRATION BARRIER OVER EXT_ SHEATHING (SEE EXT. ELEV. FOR FINISH MAT'L.) ROOF SHEATHING HURRICANE STRAP ® EACH TRUSS PER FRMG. PLAN — TRUSS SETBACK PER FRMG. PLAN NAIL (2) 16d EACH SIDE �- 2x4 BLKG. ® 48' O.C. PRE-ENG. TRUSSES ® 24" O.C. 2x4 45' CROSS BRACING AT TRUSS MID -PT. AND AT 8'-0" O.C. (MAX.) 12 PER FELEV. 2x4 TRUSS BOTTOM CHORD BLKG. AT 4'-0" O.C. REFER TO FRAMING PLAN (2) 16d COMMONS TOE NAILED EA. SIDE 8x8 U-BLOCK TIE -BEAM FILLED W/ CONC. & (1) #7 BAR CONT. VERT. #5 BAR AT EA. REINF. FILLED CELL PER FDTN. PLAN GABLE END SECTION @ HIP ROOF Y-Y TOE NAIL (2) 16d EACH SIDE 2x4 TRUSS TOP CHORD BLKG. @ 48' D.C. PRE-ENG. TRUSSES AT 24' D.C. — 2X4 45" CROSS BRACING W/(2)16d NAILS AT EA. TRUSS WEB MEMBER 2x4 45' CROSS BRACING SCHEDULE SPAN BRACING REQ'D. GREATER THAN 20 FT. SPACED 4'-0' O.C. 10 FT. TO 20 FT. (3) PAIRS AT 1/4 LESS THAN 10 FT. POINTS (1) PAIR AT MIDPOINT 2x4 TRUSS BOTTOM CHORD BLKG. AT 4'-0' O.C. REFER TO FRMG. PLAN — (2) 16d COMMONS TOE NAILED EA. SIDE 8x8 U-BLOCK TIE -BM. FILLED W/ CONC. & (1) #5 BAR CONT. VERT. #5 BAR AT EA. REINF. FILLED CELL PER FDN. PLAN GABLE END SECTION X-X 7/16 DSB DECKING 2x4 BLKG. @ 48' D.C. ALUM. FASCIA & DRIP EDGE (2) 16d COMMON NAILS AT EA, 2X4 LADDER FRAMING 2X4 STRONGBACK IF GABLE TRUSS IS �— TALLER THAN 8'-0' GABLE END TRUSS SET 3/4' FROM FACE OF CONC. BLOCK 7/16' SHEATHING OVER GABLE END TRUSS FASTEN WITH 8d NAILS AT 6' O.C. I 2X4 'T' OR 'L' STRONGBACK AT GABLE VERTICAL LONGER THAN 48' - CONNECT WITH 12d NAILS AT 12' D.C, SIMPSON HETA20 AT EACH TRUSS VERT WEB MEMBER (24' O.C. MAX) COMMON NAILS AT 6' O.C. TO 2x6 P.T. PLATE _LV16d STUCCO FINISH OVER FRAME CDNSTRUCTIION APPLIED 2 LAYERS OF AN APPROVED N WATER RESISTANT BARRIER MATERIAL DR I LAYER OVER AN APPROVED HOUSE WRAP, EXPANSION JOINT AT STUCCO FINISH 2x6 P.T. PLATE CONT. W/ 1/2'x 8' ANCHOR BOLTS @ 32' O.C. MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE -RESIDENTIAL (6TH EDITION) MICHAEL C. ANDERSON FL. LIC. AR0017305 PLAN REVIEW REVISIONS MASTER PLAN REVISION 10-16-18 Q)co ® Q 6-1 C�d �I w co CYD Lo Lo m � N O C9 w W (o CN o r s J X " cr) Q z ap LL J W 0 0 J m Q co N J cawLLmC9 Z0<t- w ur) z r^) (L W J W h PROJECT NO. 17-015-038 DATE DRAWN 8-7-18 DRAWN BY MCA CAYMAN 1763 B3 LIVING 1763 SQFT GARAGE 387 SQFT LANAI 148 SQFT ENTRY 38 SQFT TOTAL 2336 SQFT CUBIC VOLUME OF CONDITIONED SPACE _ 14,816.1 CUBIC FEET SHEET A 6m2 OPEN TO FAMILY RM. BEYOND BAR TOP Eno m is I" KITCHEN FAMILY RM. BEYOND W3C 0 36 0 W3 0 12 0 W3 0 24 0 HOOD 100 F-1 To BREAKFAST ROOM RAD. [01 N mil B 15 FILLER IILLER RNG KIT. AT RNG. KIT. NOTES: 1. BATHROOM TOWEL BARS AT 54" A.F.F. 2. BOTTOM OF MEDICINE CABINETS AT 54" A.F.F. 3. TOP OF BATHROOM SHOWER TILE TO CEILING HT. 4. SHOWER HEADS AT 6'-8" A.F.F. 0 �_ _ I Z tZ r� < 0 30 I = RAID. 0 El OPEN oo 1, TO 1 0 HALL D_ O HALL ARCH WALL MTD. LT. FILLER BATH 2 CER. TI LE RAISE BARI -FILLER W3 12 0 0 REF W21 II OPEN TO 30 BEYOND 0 AT SINK SINK n MIa�l m DW DW/REF WALL MTD. LT. MIRROR /// FILLER L A V LAV J 0 0 0 0 w 0�_ Lu I Z t1 Y > 0 MOOno j M. BATH VANITY GREAT RM. WALL ELEVATION 14" 3/4" MICA TOP ON SHIM SCREWED TO SECURE 1 X 4 TOP PLATE WOOD TRIM NOTE: NO REVEAL BETWEEN BACKSPLASH AND TOP 2x4 STUDS Li AT 16" O.C. r) 1 /2" DRYWALL rn = 0 o- KITCHEN BASE CABINET 7 BARTOP DETAIL MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE -RESIDENTIAL i6TH EDITIOI MICHAEL C. ANDERSON 1D1/ Y//,, FL. LIC. AR0017305 PLAN REVIEW MASTER PLAN REVISION 10-16-18 Lo Lo o) C) N o o') �w wID� 0 �~(n"- w MX LL U Q U N /11 p�0om W J m 0 N mow" z < I-- Ix�c~nz N O n S M a w J w 17 PROJECT NO. 17-015-038 DATE DRAWN 8-7-18 DRAWN BY MCA CAYMAN 1763 B3 LIVING 1763 SQFT GARAGE 387 SQFT LANAI 148 SQFT ENTRY 38 SQFT TOTAL 2336 SQFT CUBIC VOLUME OF CONDITIONED SPACE _ 14.816.1 CUBIC FEET SHEET A 7mO ALL DUCTWORK PENETRATING GE CEILING SHALL BE R-6 GLASS DUCT WORK. R VENT I WALL AC-1 EQUIPMENT SCHEDULE: MFG. CARRIER 3 TON C.U. CH14NBO360OG A.H.U. FB4CNF042 HEAT 05 KW COOLING CAP. 35,600 HEAT CAP. 34,000 ELECT. 208-230-1 BRKR. CU - 35 AHU - 30 REF. LINES 3/4 & 3/8 S.E.E.R. 14.00 HSPF 8.5 RETURN GRILLE SUPPLY DUCT A.H,U. PRIMARY DRAIN DRYWALL STAND AIR HANDLER DETAIL HVAC PLAN 1/4" = 1'-0" CoMmyam uw filmh, ' 4,3 AR COOLED CONDENSING UNIT SLAB MOUNTED mm MICHAEL C. ANDERSON, ARCHITECT OF RECORD FL. LIC. AR0017305 1020 SW PROVINCETOWN LANE, PORT ST. LUCIE, FL 34953 (772)418-2118 PLANS DESIGNED TO MEET THE REQUIREMENTS OF THE 2017 FLORIDA BUILDING CODE -RESIDENTIAL (6TH EDITION) MICHAEL C. ANDERSON le8ff/ g FL. LIC. AR0017305 7F-7777777, W REVI MASTER PLAN REVISION 10-16-18 ti W� o � �Q co jK' W O O V ti f q 48 l W 00 w -V 0 Lo Lo r N O (o w CO N O ~ w J inMQ z LL co 04 LL oiFro O J m Q N r �CD wwcoCO ZOQ�U En Z ti O M 0 w J w H PROJECT NO. 17-015-038 DATE DRAWN 8-7-18 DRAWN BY MCA CAYMAN 1763 B3 LIVING 1763 SQFT GARAGE 387 SQFT LANAI 148 SQFT ENTRY 38 SQFT TOTAL 2336 SQFT CUBIC VOLUME OF CONDITIONED SPACE _ 14,816.1 CUBIC FEET SHEET A 8mO M 0 12' 4" 23' 0" 15' 0" PLYWOOD NAILER BY BLDR 12' - 11" FLAT CLG T01GE I 6' 4" 381011 N 19' 4" q 2" ACCESS 1 b �--- `-.1 h a b N CD N 1 NOTE: TRUSSES ARE DESIGNED FOR ASPHALT SHINGLES. IF OTHER ROOFING MATERIAL IS USED, PLEASE NOTIFY TRUSS MANUFACTURER. O M O L\ M • HATCH LEGEND 1 SLOPE CLG 8' - 8" C1g. Hgt. r 8' - 0" A.F.F. 12'-11" Truss Load Alert Box Truss I.D. Gravity (> 5,000#) / Uplift (> - Horizontal (> 350#) n FILE CO * NOTE: ALL TRUSS TO WALL AND/OR TRUSS TO LEDGER CONNECTIONS BY BUILDER = °° (UNLESS NOTED OTHERWISE) - _ awe=���•d� * NOTE: ALL CEILING DROPS BELOW BEAM ARE d N = e o BY BUILDER (UNLESS NOTED OTHERWISE) - 9 ' d = s e o y c o o m o * NOTE: THIS TRUSS PLACEMENT DIAGRAM IS TO SHOW a = o y ` _ TRUSS I.D. AND TRUSS LOCATION ONLY. a _' n THE BUILDING DESIGNER IS REPSONSIBLE FOR THE = c STRUCTURAL STABILITY OF THE ENTIRE STRUCTURE. e .- e e H O C e] N REFER TO THE INDIVIDUAL TRUSS ENGINEERING DRAWINGS FOR GRAVITY AND UPLIFT LOADS. Q M ' _ FOR BRACING & ERECTION DETAILS REFER " s e E c v a e •- N "- +- TO BCSI-03 AND/OR ENGINEER OF RECORD e i ^ O O N AD R 14 m 'm � 3 � c •= REPRESENTS THE LEFT SIDE OF EACH TRUSS DRAWING s „ ; 4o a c a�03eaADe (A JUS24 N " H�`THD46 CQ)e ° > o E = c CB) JUS26 D MSH422 o = ; „ = o �i THD26 K) MUS26 e v �D) THD28 lL > - - a s N e THD26-2 OF THD28-2 - - - _L - 44 2 _ m C = e e e JUS46�El � = - y 6 N N N c HBB' HANGER BY BUILDER BB� BEAM BY BUILDER d 9 R e * NOTE: UPLIFT CONNECTIONS FOR ALL COMMON d °�- TRUSSES BEARING ON ANOTHER TRUSS TO BE LSTA12 = W " 9 T = e! STRAP (BY OTHERS) UNLESS NOTED OTHERWISE Wes " (EXCLUDES VALLEY AND PIGGYBACK TRUSSES) 5 N e e LOADING ROOF FLOOR WIND LOAD _ a N _ ; m .� .E a c e N= �LIVE D 20 ASCE 7-10oN a 0 m c E e _ ~ 0 DEAD LOAD 7 160 MPH EXP B e F LIVE LOAD 10* CATEGORY 11 9 0 o 00 -�— P ao 5 DEAD LOAD 10 ENCLOSED = E ' e N TOTAL LOAD 37 G FBC - 2017 ` _ e m o v DURATION FACTOR 1.25 TPI - 2014 o T REVI DATE BY REMARKS GABLE END TRUSSES REVISED. BALLOON s = 9 9 1 03/13/15 RH FRAMING REQ e e d " ❑ BALLOON FRAMING WALLS REMOVED. NOTE _ = r = 2 08/21/15 RH REMOVED ; 5 " = e ; o, LAYOUT UPDATED W/ CURRENT ENGINEER = _ '� 3 08/21/15 RH ;NAME a o d M=" e� — 3� 4 10/12/17 RH LAYOUTUPDATED d fi: _ s " 7ff 3 e c Lc c 5 10/ 12/ 17 RH EYEBROW TRUSSES ADDED OVER REAR PORCH j , cc 6 08/29/18 RH UPDATED CODE E " c o e o E e o= O > O 6.- u !� a >• E An N L e R 7 08/29/18 RH EXTENDED LANAI2' It is understood that above = p e �' conditions have been reviewed J APPROVED E e = e o c v w ac v o a & are acceptable for the fabrication at trusses, ❑ APPROVED AS NOTED =.9 E € N elevations, pitches, overhangs, fascias,ceiling REVISE AND RESUBMIT ��9�.NeNNe elevations/pitches, bearing d 9 e a _ m= -londitions & all detail pertaining REJECTED N a c s E w to this truss placement plan. No �E ❑ `ey-ski back charges will be accepted 9 DATE T- " t N =- 3 E AD without previous written = = o o approval from an A-1 Roof " ` S Trusses representative. REVIEWED BY e o 'm e E a PLAN DATE ARCH: 05/16/17 STRUCT: E /-/— _ d 9 E H _ = "e- N CUSTOMER RENAR HOMES - e JOB NAME OWENS RESIDENCEcc d a 3 s e N AD >• s c `y o, m e e OPTION(S) 15 X 10 COVERED LANAI E V e COMMNTY L = _ _ L®T # MORNINGSIDEI LOT 38 / =CL: „' AD CITY FT PIERCE e e v e- o = COUNTY S L LUCIE, FL L E m 'n- —:a aa AD Jg �/�y /r /� p j v = BLDG BLDG I' � e, = e TYPE 1763 �3 # - _ a s o = m•d �._.9 �I E: c y c a c e I E a ram-. a o e JOB # 73922 MASTER WRMSCMB3L15X10 D t " s c e T :i= E `e ` `o a DRAWN SCALE 'a t A o AnthonyT.TDmbDIII DATE 08/29/18 _ s = I rno 00 � ,��,•��,�,�^" xuvr nz 2977e2 " ••" FASCIA 413 n HIP LINE 62 R SERIAL, #`: IVALLEY LINE 0 R 4d36b989999e20a51 bEQCI2SL N6 AREA UNDER VALLEY TRUSSES AND WASTE MATERIAL NOT INCLUDED OLOR TO VERIFY CALCULATIONS RH N.T.S. o ee�=sue Z ° �e s u 44\.A. c 4AP"III• 0 e c O R= A-1 OG O 6 a o oA06*--TRUSSES � A FLORIDA CORPORATION Ph 772-409-1010 / Fax 772-409-1015 y ,� e a? _ o f '3a e http://Www.aItruss,com ~ = _ _ „ e a R a