HomeMy WebLinkAboutBUILDING SITE PLANJOB SPECIFIC GENERAL NOTES: 1. HOUSE IS IN A NEGLIGIBLE WEATHER AREA 2. HOUSE IS IN A VERY HEAVY TERMITE AREA. 3. FLAME SPREAD FOR WALLS AND CEILING FINISHES SHALL BE LESS THAN 200. 4. FLAME SPREAD FOR INSULATION SHALL BE LESS THAN 25 5. SMOKE DEVELOPED INDEX SHALL BE LESS THE 450 FOR WALL FINISHES, CEILING FINISH AND INSULATION 6. GYPSUM BOARD SHALL CONFORM TO FBC R702.3 STANDARDS 7. TILE IN SHOWERS MUST BE BACKED BY "DURA ROCK" CONCRETE BOARD OR EQUAL 8. EGRESS WINDOWS COMPLY WITH 2O17 FBCR 6TH EDITION R310.2.1 MIN. NET CLEAR OPENING OF 5.0 S.F. 9. DRYER VENT TO OUTSIDE 10. LOW FLOW PLUMBING FIXTURES GENERAL NOTES: I CONCRETE NOTES: THE BUILDER SHALL REVIEW DRAWINGS IN THEIR ENTIRETY BEFORE STARTING CONCRETE HAS BEEN PERFORMED IN ACCORDANCE WITH ACI 318-05, BUILDING WORK. THE BUILDER SHALL ACCEPT FULL RESPONSIBILITY FOR ANY ERROR OR CODE REQUIREMENTS FIR STRUCTURAL CONCRETE OMISSIONS NOT REPORTED IMMEDIATELY IN WRITING TO ENGINEER OF RECORD. BY SUBMITTING THESE PLANS FOR PERMIT THE BUILDER ACCEPTS FULL NORMAL WEIGHT CONCRETE (145 PCF) 28-DAY COMPRESSIVE STRENGTHS. RESPONSIBILITY FOR THE ACCURACY OF THE INFORMATION DEPICTED WITHIN PILING 500 PSI WITH .40 WATER -CEMENT RATIO AND IT IS ASSUMED THE BUILDER HAS READ AND UNDERSTANDS THE NOTES SHALLOW FOUNDATIONS 2500 PSI. BELOW. PILE SUPPORTED FOUNDATIONS 5000 PSI WITH .40 WATER -CEMENT RATIO COLUMNS, BEAMS, AND ELEVATED SLABS, 3000 PSI. DESIGN LOADS IN ACCORDANCE WITH 2O17 FBC 6TH EDITION CHAP. 16 CONCRETE SLUMP SHALL BE AS FOLLOWS SLUMP IN INCHES ASSUMED SOIL BEARING CAPACITY: 2500 PSF MIN MAX MASSIVE SECTIONS, PAVEMENTS, AND SLABS 1Y2" 4" STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB HEAVY SLABS, BEAMS, WALLS 3" 5" SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND THIN WALLS, COLUMNS 3Y2" 6" SITE DRAWINGS MINIMUM CONCRETE CLEAR COVER SHALL BE: CONSULT ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER SLAB - -)/4" DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. BEAMS AND COLUMNS - 1Y2" 11 ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TIE COLUMNS - 74 TYPICAL AND SHALL BE CONSTRUED TO ANY SIMILAR SITUATION ELSEWHERE ON EXPOSED UNPROTECTED CONCRETE THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. FORMED CONCRETE BELOW GRADE - 3" UNFORMED CONCRETE BELOW GRADE - 3" ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN FIELD. PLACING DRAWINGS AND BAR LISTS SHALL CONFORM TO A.C.I.'S "MANUAL OF DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. IF ANY STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES."(A.C.I. DISCREPANCIES ARE DISCOVER THE ENGINEER OF RECORD MUST BE CONTACTED 315) BEFORE THE COMMENCEMENT OF CONSTRUCTION. THE STRUCTURE IS DESIGNED TO SELF SUPPORTING AND STABLE AFTER DETAILS OF CONCRETE REINFORCEMENT SHALL BE IN ACCORDANCE WITH "MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION." BUILDING IS COMPLETE. AS PUBLISHED BY THE CONCRETE REINFORCING STEEL INSTITUTE UNLESS IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES OTHERWISE INDICATED. TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. CONCRETE CONSTRUCTION TECHNIQUES SHALL CONFORM TO THE THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" (A.C.I. 301) TEMPORARY BRACING, GUYS OR TIEDOWNS. THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND ADEQUATE VERTICAL AND HORIZONTAL SHORING SHALL BE PROVIDED TO SAFELY SITE PREPARATION REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE SUPPORT ALL CONSTRUCTION LOADS CONSTRUCTION LOADS. CONCRETE BEAM SIZES MAY BE INCRE;SED AS REQUIRED FOR ARCHITECTURAL THE STRUCTURAL FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER, THE DETAILS OR TO FIT BLOCK COURSING. SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE CONCRETE ETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF A.C.I 301 AND FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL FLOOR DESIGNERS ASTM FOR MEASURING, MIXING, TRANSPORTING, ETC. LAYOUT. PROVIDE SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR APPROVAL. REVIEW OF SHOP DRAWINGS IS REQUIRED AS THE ENGIN _ER CONCRETE TICKETS SHALL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. CHECKS BEAM, WALL, COLUMN AND FOOTING CAPACITIES AGAINST THE MAXIMUM TIME ALLOWED FROM WHEN WATER IS ADDED TO THE MIX UNTIL LOADING. FAILURE TO PROVIDE SHOP DRAWINGS MAY RESUL ADDITIONAL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF ENGINEERING COSTS DURING CONSTRUCTION. _ FOR ANY REASON THERE IS A DELAY SUCH THAT A BATCH IS HELD FOR R703.8 FLASHING. y LONGER THE 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED, APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN A 'MANNER TO PREVENT ENTRY OF WATER INTO THE CALCIUM CHLORIDES SHALL NOT BE UTILIZED IN THE WORK. WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL OTHER ADMIXTURES MAY BE USED ONLY WITH THE APPROVAL OF THE ENGINEER. FRAMING COMPONENTS. SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. THE FLASHING SHALL EXTEND TO THE FBC PROVIDES AN EXCEPTION FOR RESIDENTIAL CONSTRUCTION WHERE CONTROL SURFACE OF THE EXTERIOR WALL FINISH. APPROVED JOINTS ARE NOT REQUIRED. HOWEVER, IN THAT EXCEPTION, IT SAYS THAT THE CORROSION -RESISTANT FLASHING SHALL BE INSTALLED AT ALL OF THE EXCEPTION IS ALLOWED WHERE THE OWNER ACKNOWLEDGES THAT CRACKS ARE FOLLOWING LOCATIONS: ACCEPTABLE AND UNDERSTOOD. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WELDED WIRE MESH: WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF WELDED WIRE MESH SHALL BE ASTM A185, GRADE 65, FREE FROM OIL, SCALE, THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER AND RUST AND SHALL BE PLACED IN ACCORDANCE WITH ACI TYPICAL DETAILS. FOR SUBSEQUENT DRAINAGE. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. MORE OF THE FOLLOWING OR OTHER APPROVED METHOD: 1.1. THE FENESTRATION MANUFACTURER'S WRITTEN FLASHING INSTRUCTIONS. 1.2. THE FLASHING MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. 1.3. IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, OR FMA/WDMA 250. 1.4. IN ACCORDANCE WITH THE FLASHING METHOD OF A REGISTERED DESIGN PROFESSIONAL. 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. 6. AT WALL AND ROOF INTERSECTIONS. 7. AT BUILT-IN GUTTERS. MASONARY OTES: STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.1530-05/ASCE 5-02/TMS 402-02, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY ON BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. WOOD TRUSSES: WOOD TRUSSES TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATIONS FOR SDTRESS-GRADE LUMBER AND IT FASTENINGS" BY NFPA FILE COPY NISI/DN ST. LUCIE COON BUILDIN REVIEWED FOR COMPLIA C l REVIEWED BY N F BE I EPT ON JOB DATE pLANS AND PERMIT M4 % S WILL BE MADE SITE OR NO INSPECTIOTNI( ) ALLPR0PO5E0WORK SPSISEJ�P`RT10 AESE rNC PEIR HAT EIO U1Cwoss. MENE C0100 WISH � y1,30WING �ppy tA�� CE Pj1 tAWUwACYUOS%AGC EMUS U F,N TM FpC ENEFORNO)S �W1 0NE0S "EMNO ON E'TION5 APE PPPP UNT111NSP CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD. PROJECT DESIGN DATA CODE FBC 2017 6th Edition PROJECT NAME See Border PROJECT ADDRESS See Border ARCHITECT/ENGINE:.:R See Border WIND IMPORTANCE/USE FACTOR 1. INTERNAL PRESSURE COEFFICIENT 0.18 RISK CATEGORY _ It WIND SPEED (3 Sec Gust) 160 MPH EXPOSURE C MEAN BUILDING HEIGHT =15'4' OVERHANG 2'_0 ROOF PITCH 3:12 and 6:12 COMPONENTS & CLADDING WIND PRESSURES See Elevations ROOF DEAD LOAD . ...............,.,.....,.,.,..,...,..,...,,....................., See Truss Engineerml ROOF LIVE LOAD See Truss Engineerinj FORMWORK: FLUOR LIVE LOAD N!A TRUSS DESIGN SHALL COMPLY WITH TPI/WTCABCSI 1-03 BUILDING ,,,,, ,,,,,,, „ , , ..... FORMWORK SHORING, AND BRACING FOR ALL CONCRETE BEAMS, COLUMNS, COMPONENT SAFETY INFORMATION GUIDE TO GOOD PRACTICE FOR HANDLING, SHUTTERS NO WALLS, AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE INSTALLING, & BRACING OF METAL PLATE CONNECTED WOOD TRUSSES" AND WITH A C 1 347 "RECOMMENDED PRACTICE FOR CONCRETE FORMWORK" TPI 1-02 "NATIONAL DESIGN STANDARD FOR METAL -PLATE -CONNECTED WOOD IMPACT RESISTANT ASSEMBLY Yes CONSTRUCTION ANY AND ALL PLUMBING PIPE PENETRATIONS THROUGH FORMED WORK SHOULD TIMBER NOTES: BE DONE SO THAT REINFORCING STEEL IS NOT DISRUPTED AND COVER FOR TRUSS DESIGNS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER STEEL IS NOT AFFECTED REGISTERED IN FLORIDA. ALL WOOD MEMBERS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE NATIONAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.1530-05/ASCE 6-02/TMS DESIGN SPECIFICATION FOR WOOD CONSTRUCTION AND ITS SUPPLEMENT, (NDS) SPECIFICATIONS FOR MASONRY STRUCTURES AND THE COMMENTARY ANY UTILITY PIPES PENETRATING FOOTERS TO BE PROPERLY SLEEVED TO AVOID SEE NOTES FOR SHOP DRAWINGS, ON SPECIFICATIONS FOR MASONRY STRUCTURES. ON SSE, PIPED UTILITIES FROM BEING SHEARED DURING SETTLEMENT OF STRUCTURE ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BLOCKING, CONNECTOR PLATES SHALL BE A MINIMUM THICKNESS OF 0.036" AND BE BRACING, LEDGERS, CRIPPLES, SILLS, ETC... SHALL BE SOUTHERN PINE NO. 2, ALL BLOCK WALLS SHALL BE TWO CELL HOLLOW CONCRETE MASONRY REGULAR ELECTRICAL PIPES INSIDE OF THE POURED COLUMNS SO THAT THEY DO NOT MANUFACTURED FROM STEEL MEETING THE REQUIREMENTS OF ASTM A446, KD-15 OR BETTER. MIN (3) 2"x UNDER ALL GIRDER BEARING (LOCATIONS. SEE SIZE BLOCK MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE, TAKE UP MORE THAN 10% OF THE CROSS -SECTIONAL AREA OF THE COLUMNS GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED. FLOOR PLAN F'm=1500 P.S.I. AND THEY DO NOT AFFECT THE COVER ON THE REINFORCING STEEL IN HIGHLY CORROSIVE ENVIRONMENTS, CONNECTOR PLATE AS WELL AS THE MICRO LAM BEAMS SHALL BE MANUFACTURED BY TRUS-JOIST CORP., OR AND BLOCK SHALL BE PLACED IN RUNNING BOND UNLESS OTHERWISE NOTED. LAY REINFORCING STEEL NOTES: HURRICANE STRAPS AND ALL THE NAILS, SHALL BE HOT DIPPED GALVANIZED, APPROVED EQUIVALENT AND SHALL PROVIDE A MODULUS OF ELASTICITY OF UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE PLACING CONCRETE REBAR SHALL BE ASTM A615 GRADE 60 DEFORMED BARS, FREE FROM OIL, TRIPLE ZINC S-185 COATED OR MADE OF STAINLESS STEEL. 2,000,000 PSI, A MINIMUM FLEXURAL STRENGTH OF 2,925 PSI, AND A MINIMUM FOR IN WALL COLUMNS. SCALE, AND RUST AND PLACED IN ACCORDANCE WITH THE TYPICAL BENDING HANDLING, ERECTION, AND BRACING OF TRUSSES SHALL BE IN ACCORDANCE HORIZONTAL SHEAR STRESS OF 285 PSI. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH ASTM C-476 AND DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS. WITH TRUSS PLATE INSTITUTE RECOMMENDATIONS. c ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK HALL NE SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 P.S.I AT 28 HORIZONTAL AND VERTICAL BARS SHALL LAP 60x BAR NO. SEE LAP SPLICE PRESSURE TREATED. ACCEPTABLE TREATMENTS INCLUDE ACQ. (AMINE COPPER DAYS. THE GROUT MIX SHALL HAVE A MAXIMUM 3 8" COURSE AGGREGATE / SCHEDULE UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEERS REVIEW. HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S QUAT) COPPER BORON ACID COPPER CHROMATE, AND COPPER CITRATE. AND SHALL BE PLACED WITH A SLUMP OF 8" TO 10". USE MECHANICAL INSTRUCTIONS. CONNECTORS OR STRAPS THAT DO NOT MATCH EXACTLY THE BORATE BASED TREATMENTSNTS SUCH AS ZINCBORATE AND SODIUM BORATE ARE ALSO VIBRATION TO CONSOLIDATE GROUT. ONES SPECIFIED IN THE DRAWINGS REGARDING STEEL YIELD OR ULTIMATE ACCEPTABLE FOR INDOOR USES. STRENGTH, STEEL GRADE, DIMENSIONS (LENGTH AND WIDTH), NUMBER AND TYPE S MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT MORTAR TENSION LAP SPLICE SCHEDULE: DIAMETER OF HOLES FOR THE SAME SIZES OF NAILS OR BOLTS. AND/OR DO FOR STRUCTURAL USES AVOID BUYING TREATED LUMBER THAT CONTAINS MORE SHALL BE PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270 HORIZONTAL AND VERTICAL MORTAR JOINTS SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO THE CELLS TO BE FILLED. ALLOW A MINIMUM OF 24 HOURS FOR MORTAR TO CURE PRIOR TO GROUTING CELLS. TENSION AND COMPRESSION LAPS = .OQ2 X BAR DIAMETER X Fs (NOTE THAT Fs= 24 KSI MAXIMUM (.4 X Fy)) (THIS EQUATES TO 48 X BAR DIAMETER) NUT HAVE THE SAME GENERAL SHAPE, WILL NOT BE ACCEPTABLE. THE 1/2" OF HEARTWOOD THE CONTRACTOR WILL BE RESPONSIBLE FOR KEEPING THE ROOF SAFELY IN PLACE IN PLACE IN THE EVENT OF HIGH WINDS TRANSIENT LOADING CONDITIONS DURING CONSTRUCTION ***FAILURE TO COMPLY WITH THESE PARAMETER WILL MAKE THE CONTRACTOR SOLELY RESPONSIBLE FOR ANY AND ALL CONSEQUENTIAL DAMAGES CAUSED BT THE HORIZONTAL THRUST DEVELOPED BY THE ROOF FRAMING DUE TO SUPERIMPOSED LOADING AND TRANSFERRED INTO THE BEAMS, WALLS, AND COLUMNS. MASONRY CONSTRUCTION SHALL BE PERFORMED UNDER THE DIRECT PROVIDE CORNER BARS LAPPED AND TIED TO EACH BEAM REBAR, TYPICAL AT CONTRACTOR SHALL SUBMIT SIGNED SEALED DRAWINGS OF ALTERNATE SUPERVISION OF A "CERTIFIED STRUCTURAL MASONRY CONTRACTOR". THE ALL CORNERS, THESE CORNER BARS SHALL BE THE SAME SIZE AS CONNECTION DETAILS AT TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR SUPERVISOR OF THE MASONRY PORTION OF THE PROJECT SHALL BE A LONGITUDINAL BEAM BARS, SEE DETAILS FOR ADDITIONAL INFORMATION. APPROVAL. ]'LAIN REIN FORCKMENT BAR NO MASONRY SP1ACI? 07twi? TEAN Too TOP BARS 86OO PSL4060 PS1 3000 PSIi4000 PSI 3 16" 16" 21" 1 In" 3 21" 22 19�y 28," h" 1, �30- P. f.,. +. 6" 05' :.30.., 7 42" 4B" 4P,. 60,, F4,, "CERTIFIED STRUCTURAL MASONRY CONTRACTOR" OF A CERTIFIED STRUCTURAL MASON" AS RECOGNIZED BY THE FLORIDA CONCRETE AND PRODUCTS REINFORCEMENT SHALL BE CAREFULLY PLACED, RIGIDLY SUPPORTED AND WELL ASSOCIATION(FC&PA). THE SENIOR MASONRY SUPERVISOR WILL BE RESPONSIBLE TIED WITH BAR SUPPORTS AND SPACERS. TO ASSURE THAT THE WORK IS ACCOMPLISHED IN ACCORDANCE WITH THE REINFORCING STEEL IN FOOTINGS SHALL BE ASSEMBLED AS MATS WITH BARS CONTRACT DOCUMENTS. THE MASONRY CONTRACTOR SHALL SUBMIT EQUALLY SPACED AND WIRED TOGETHER AT EACH INTERSECTION BEFORE CREDENTIALS FOR THE FC&PA TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO BIDDING. CONCRETE IS PLACED. REINFORCING BAR SHALL BE IN ALL WALL INTERSECTIONS AND AT EACH SIDE DOWEL COLUMN AND WALL REINFORCING TO FOOTING WITH SAME SIZE AND OF ALL OPENINGS. NUMBER OF DOWELS AS VERTICAL BARS ABOVE. POURED DOWNCELL TO BE AT EVERY GIRDER LOCATION AND REINFORCING BARS DOWEL SHALL BE HOOKED "L" AT BOTTOM AND SHALL BE LAPPED 36 BAR SHALL BE AT ALL DEL. GIRDER TRUSSES DIAMETER WITH THE COLUMN OR WALL REINFORCING ABOVE. THE ENGINEER AND ITS CONSULTANTS OR DESIGN PROFESSIONALS WILL NOT BE RESPONSIBLE FOR ANY DAMAGE CAUSED AS A CONSEQUENCE OF TERMITE INFESTATION. THE LOCATIONS OF GIRDERS AND TRUSSES SHOWN ON THE ROOF FRAMING PLAN WERE USED TO FACILITATE DESIGN OF FOUNDATIONS, WALLS, AND BEAMS, THE CONTRACTOR SHALL SUBMIT TRUSS SHOP DRAWINGS FOR REVIEW BY THE STRUCTURAL ENGINEER OF RECORD PRIOR TO FABRICATION. THE TRUSS FABRICATOR SHALL PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION PLAN SHOWING COMPONENT LAYOUT. AVOID INHALATION OF SAWDUST PRODUCED BY PRESSURE TREATED WOOD, WEAR A DUST MASK AND WORK OUTDOORS. DISPOSE OF DUST AND SCRAP BY ORDINARY TRASH COLLECTION. DO NOT BURN. PRESSURE TREATED WOOD MAY PRODUCE TOXIC FUMES. IN HIGHLY CORROSIVE ENVIRONMENTS ALL WIND RESISTING HARDWARE INCLUDING THE HURRICANE STRAPS SHALL BE MADE OF STAINLESS STEEL OR SHALL BE DIPPED (AND SCRATCHES REPAINTED) IN COL -TAR EPDXY PAIM HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. HANGERS OR STRAPS THAT DO NOT MATCH EXACTLY TO THE ONES SPECIFIED ON THE DRAWINGS IN STEEL YIELD OR ULTIMATE STRENGTH, STEEL DIMENSIONS (LENGTH AND WIDTH), NUMBER AND DIAMETER OF HOLES FOR SAME SIZES OF NAILS OR BOLTS, AND/OR DO NOT HAVE THE SAME GENERAL SHAPE WILL NOT BE ACCEPTABLE. NO POCKETS WILL BE ALLOWED IN CONCRETE OR STEEL MEMBERS FOR CONNECTION OF WOOD MEMBERS UNLESS CONNECTION DETAIL IS IN WRITING PRIOR TO INSTALLATION. ALL NAILS, SCREWS, AND BOLTS SHALL BE HOT -DIPPED GALVANIZED. 7' 1 G'2009 Sheet Index C1.0 Cover Page A1.0 Elevations, Floor Plan, Typ. Wall Section S1.0 Beam Plan, Foundation Plan S2.0 Truss Strapping & Roofing Details M1.0 Electrical and HVAC Layout FDOH in St. Lucie County ,Environmental Health Site Plan Approved for Construction Supersedes All Previous Site Plans for rDs #61-W, iyt(*cr'9 & Well # S9. 9iw J Revisions: No. Date Description Drawn: Issue Date: J.D. XX.XX.XXXX 7 /r � ' I.C.E.D. Services LLC. Independent Coordinators for Engineering & Drafting Services (352) 900-ICED Phone Jdiaz@ICEDServices.com Builder: iMnil DsyslapIng, Ino, 1081 SW Bianca Ave. Port Saint Lucie, FL (772) 828-9402 phone Lic #: CBC-1261264 Project: New Single Family Residence 11100 Carlton Rd. Port Saint Lucie, FL. St. Lucie County Sheet Title: Cover Page Sheet #: C1.0 Engineer: SOUTHEAST BUILDING ENGINEERS PE-64781 S� 5911 Pescara Dr. UGC Pace, FL 32571 772-774-9086 phone TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE W/ SECTION 1609 OF THE 2017 FLORIDA BUILDING CODE 6TH ED. 1 S ott R. Sanders, P.E. FL P.E. No. 64781 RIGHT T SIDE ]ELEVATION SCALE i4 12 6 4'—0" L EFT SI[I DBE DEL VATION SCALE %a"=1'-0" "5V" METAL ROOFING ATTACHED AS PER MFG. SPECS OVER (1) LAYER OF 30 LB FELT OVER OVER rb2" PLYWOOD INSTALLED STAGGERED AND FASTENED TO PRE-ENGINEERED TRUSSES W/ 8D RINGSHANKS NAILS 0 6" O.C. EDGES AND 6" ON CENTER IN FIELD MTL. DRIP EDGE VIRSIrAo 2"x6" FASCIA 2'-0" STUCCO SOFFIT INSTALLED AS EXTERIOR CEILING DETAIL 0 STUCCO SIDING R-30 SPRAY 5/8" CIELING DRYWALL MTL. STRAP SEE STRAP SCHEDULE FOR DETAILS DBL. COURSE OF BEAM BLOCK W/ (1) #5 CONT. REBAR W/ CORNER BENDS FILLED W/ 3000 PSI CONC EA. COURSE Y2" DRYWALL #5 REBAR W/ 10" BEND N BEAM IN FILLED CELL o W/ 3000 PSI GONG, 4'-0" O.C. MAX & ALL JAMBS, CORNERS, AND BENEATH GIRDER BEARING LOCATIONS 3/4" FOIL BACKED INSUL. OVER 1"x2" FURRING STRIPS @ 24" O.C. SEE SHEET S1 FOR FOOTER STEEL DETAILS WOOD BASE BOARD FLOOR COVERING TO BE DETERMINED IN FIELD 4 a d SEE SHEET S1 FOR FOOTER DETAILS TYPICAL WALL SECTION SCALE: 3/4"=1'-0" _ �— — -- - — -- AREA SCHEDULE 1 I 1 I I I I I I I I I I I I I I i I l I ' I I I L-----t------------ ------ ------ ----- - -- ------ --------------------------------- ------ ------ L - ----- J I, C LIVING A/C 1,436 Sq Ft. FRONT PORCH 384 Sq Ft. Sq Ft. Sq Ft. TOTAL 1,820 Sq Ft. C&C Vasd Wall Wind Pressures 160 C Risk Cat. II 11<15 Ft. Zone 4 Interior Zone 5 Exterior A) 10 SF = +33.5 / -36.3 E) 10 SF = +33.5 / -44.8 B) 20 SF = +31.9 / -33.9 F) 20 SF = +31.9 / -41.1 C) 50 SF = +29.9 / -32.7 G) 50 SF = +29.9 / -37.5 D)100 SF = +28.4 / -30.3 H)100 SF = +28.4 / -33.9 E)500 SF = +24.9 / -26.6 I)500 SF = +24.9 / -26.6 RoofC&C Pressures Zone 1: -25.3 Zone 2: -53.4 Zone 3: -78.8 t FRONT ELEVATION SCALE i4 FOIL BACK INSULATION CBS BLOCK WALL & LINTEL 1 %2" P.T. FURRING STRIP Y2" EXTERIOR DRYWALL SIDING - TAPCONS SEE 1 %4" P.T. PRODUCT APPROVAL "x4" P.T. AFFIDAVIT FOR TYPE WOOD BUCK AND SPACING Window Head Note: All bucks to be flashed in compliance with R703.6 as listed on sheet C1 CBS BLOCK WALL & LINTEL EXTERIOR SIDING Y2" DRYWALL 1 %2" P.T. 1 "x4" PITA TIF 1 x P.T. BUCK FURRING STRIP "x4" P.T. WOOD BUCK USED THAN Y4"2x23/4" TAPCONS THRU DOOR FOIL BACK FRAME AS PER INSULATION PRODUCT SPECS CBS BLOCK (SEE PRODUCT WALL APPROVAL AFFIDAVIT). F 2X P.T. BUCK USED THAN 3/s"x3Y4" PCONS SEE TAPCONS SPACED AS EXTERIOR PRODUCT APPROVAL PER PRODUCT SIDING AFFIDAVIT FOR TYPE APPROVAL. AND SPACING Window Jamb TYPICAL WINDOW AND DOOR DETAILS PRE—ENG. TRUSSES { WIRE LATH STUCCOS l\ OPENING& WIRE LATH SHALL BE ATTACHED ACCORDING TO ONE OF THE FOLLOWING METHODS (FINAL METHOD TO BE DETERMINED IN FIELD): 1. DIAMOND —MESH EXPANDED METAL LATH, FLAT —RIB EXPANDED METAL LATH AND WIRE LATH SHALL BE ATTACHED TO HORIZONTAL WOOD' FRAMING MEMBERS WITH 1Y2" ROOFING NAILS DRIVEN FLUSH WITH PLASTER BASE. (ASTM 7.10.2.2) 2. EXPANDED %" RIB LATH SHALL BE ATTACHED TO HORIZONTAL WOOD FRAMING MEMBERS WITH NAILS OR STAPLES TO PROVIDE NOT LESS THAN 13/4" PENETRATION INTO WOOD FRAMING. (ASTM 7.10.2.3) WITH EITHER METHOD THE SPACING OF FASTENERS TO BE 7" O.C. ALONG SUPPORTS AS PER ASTM 7.10.2.1 AS PER ASTM 7.10.2.4 IF COMMON NAILS ARE USED THEY SHALL BE BENT OVER TO ENGAGE NOT LESS THE THREE STRANDS OF LATH, OR BE BENT OVER A RIB IF RIB LATH IS INSTALLED In N w N W FOIL BACK INSULATION DOOR THRESHOLD FASTEN 1 "x4" P.T. AS R FOIL BACK 1 "x2" P.T. PRODUCTONS APPROVAL INSULATION FURRING STRIPAf DOOR PANEL 1 "x2" P.T. FURRING STRIP 1'2" ® - DRYWALL 1 "x4" P.T. CBS BLOCK WALL ATTACH P.T. DOOR BUCKS IN SUCH A ATTACH P.T. DOOR MANNER AS TO, AS A MINIMUM, COVER BUCKS IN SUCH A EXTERIOR THE ENTIRE WIDTH (AS MEASURED FROM MANNER AS T0, AS A SIDING INSIDE TO OUTSIDE) OF PREHUNG DOOR MINIMUM, COVER THE JAMB. ENTIRE WIDTH AS IF 1x P.T. BUCK USED THAN Y4"Ox2?/4" MEASURED FROM INSIDE TO OUTSIDE) TAPCONS THRU DOOR FRAME AS PER OF PREHUNG DOOR PRODUCT SPECS (SEE PRODUCT JAMB. APPROVAL AFFIDAVIT). IF 2X P.T. BUCK USED THAN Y,6"x34" TAPCONS SPACED AS PER PRODUCT APPROVAL. Door Head Door Jamb SCALE: 1-1/2" = 1'-0" gin'-R 4'-8" 8'-0" _1 0 -8 17'-4" > OS � Q 24 SH 24-SH -EGRESS - - ��.. WH __ __ y_ h/ r_._____ I - "3 II a I LAUNDRY Co o0 cp i KITCHEN 00 TO CABINET z 1 o'-o" FLAT 1 O 10'-0" FLAT ih FACE CEILING o BEDROOM 11 i I CEILING - � #3 1 12' I 141" I 01 -----,-- 0 10'-0" FLAT J J DINING -- - ---- -- 8'-10i" CEILING 3 —8 i i 10'-0" FLAT 14'-61" I I CEILING I I° � '. W.I.C. 26ao I I � I MASTER ___ I H Wa H BATH"T 11I II1I I1III L-----I-----I < U 10LAT CEILINFG iI11I 1I • IIi 8 5'-61„ Q Ii [LCI) < BATH 2 u'01 #Q 00 _ 0'-01 T L_ o Y CEILING -- -- ---------------------- ---- -----------MASTER --JhIIII #2 I GREAT ROOM 1 BEDROOMo 10'-0" FLATBEDROOM CEILING d 10'-0" FLAT in - 10'-0" FLAT CEILING I 5mo CEILING rn 12 2' 41' 20'-44" 14'-61" 0 I 03UJL__"° 0 II II I II I . . I I -------------- 34 SH --- - ----- _ 3080 W� ---- -- ----- 7 �H -------------- 34 SH I EGRESS 12" SIDELIGHT EGRESS I 1 14+4" 1 1'-8°' 16'-8" 12'-4" FRONT PORCH 10'-0" FLAT CEILING —------------ ----------y-------- -------------------------------- --------------------------------- ---------------------------------m I I 16" 16" , 10'-4" �16" 10'-4" �,1 6" 10'- 4" �i 6" 10'-4" 16" 16" 50'-8" ANT* d- I x n N v 0 In a SCALE: 1/4" =1'-0" Revisions: No. Date Description Drawn: Issue Date: J. D. 09.25.2018 II.C.E.D. Services LLC.I Independent Coordinators for Engineering & Drafting Services (352) 900-ICED Phone Jdiaz@ICEDServices.com Builder: ICI 1081 SW Bianca Ave. Port Saint Lucie, FL (772) 828-9402 phone Lic #: CBC-1261264 I Project: I New Single I Family Residence 11100 Carlton Rd. Port Saint Lucie, FL St. Lucie County Sheet Title: Floor Plan & Elevations Sheet #: Al .0 Engineer: SOUTHEAST BUILDING ENGINEERS PE-64781 5911 Pescara Dr. Pace, FL 32571 772-774-9086 phone TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE W/ SECTION 1609 OF THE 2017 FLORIDA BUILDING CODE 6TH ED. FL P.E. No. 64781 CASTCRETE PRECAST LINTEL SCHEDULE FIELD ADDEDREBA R AT TOP • 1„ '#--^^^ C,MU. BOND'. BEAM BLOCK z J GROUT '- FIELD ADDED,REBAR AT � • � BOTTOM BOTTOM RE3h1FORCDNG PROVIDED IN LWEL NlOMNAL F = FILL® WITH GROUT I U = UNFILLED / S = SOLID ADDED REBAR AT BOTTOM OF LINTEL p rI ��++ ,y �y p -r� 8F 16 — 8/11 1 tdWIDTH � I WIDTH NOMINAL HEIGHT tDUAN r OF FIELD ADDEb RATTQP MARK LEPIt3Tµ COMPOSITE BEAM SAFE GRAVITY LOAD APPLIED GRAVITY LOAD SAFE UPLIFT LOAD SAFE UPLIFT LOAD LB-1 5'-10" 8F241807' 6036 802 3107 542 LB-2 5-8" 8RF221B/1T 8060 537 2854 1006 LB-3 5'•10" 8F241B/1T 6036 537 3107 1006 LB-4 51-10" 817241B/1T 6036 537 3107 1006 LB-5 v-0. SF16 1B71T 3486 <500 1815 <500 LB-6 11-8" 8F16 1611T 2193 <500 1153 <500 LB-7 1V-6" 8F16 1BOT 2193 <500 1153 <500 i8-8 11" 8F16 1BOT 2193 <500 1153 <500 LB-9 11'-8" 8F161B/1T 2193 <500 1153 <500 LB-10 8'-8" 8F161B/1T 3486 <500 1815 <50C LB-11 4-6" 8F24 1Bf1T 6113 <500 4043 <500 LB-12 T-6" BRF22 1B11'T 5743 784 2166 <500' LB-13 4' 6" 8F24 11311T 6113 784 4043 <500 LEI.14 4'-6" 8F24180T 6113 784 4043 <500 (.8-15 76" 8F24IBMT 6113 <500 4043 <50C LB-16 4'-6" 8F241B/1T 611,3 <500 4043 <500 II I Z , �' ii iN QI! - - -- LIGHT ATTIC S ORAGE I FINAL SIZE & DESIGN — — __. _ _ ____ TO BE _T DET=RMINED BY TRUSS MANUFACTURER - ALL BEAM HEIGHTS TO - BE @ 10'-0° A.F.F. - BRUSH CONCRETE SURFACE o p � p 4 Q CONCRETE Q p p 1/8" LARGER HOLE THAN ALL THREAD ROD OR REBAR. CLEAN OUT WITH BLOWOUT BULB. ODRILL COMPLETE HOLE PREPARATION WITH USE OF A NYLON BRUSH (DO NOT USE WIRE BRUSH) EPDXY TUBE CONCRETE SURFACE Q 4a 4 � p � p � EPDXY Q CONCRETE � p p PRIOR TO INJECTION, DISCHARGE ONE FLUID OUNCE OF EPDXY OR UNTIL UNIFORM IN COLOR. 02 FILL THE HOLE TO 1/2 THE HOLE DEPTH. EMBEDDED BOLT CONCRETE SURFACE OR REBAR Q 4 6' MIN. p Q CONCRETE p p INSERT ALLTHREAD ROD OR REBAR SLOWLY BY HAND INTO THE HOLE TO THE END USING A SLOW TWISTING MOTION. HARDENING WILL BEGIN IN 7 3 MINUTES AT ROOM TEMPERATURE. IMPORTANT DO NOT LOAD FOR 3 DAYS. EPDXY INSTALLATION PROCEDURES 0 c - °- #5 FOOTER STEEL EPDXIED - - MIN 6" INTO GONG AND MIN. 60 BAR LAP (25") ON � _a VERTICAL REBAR GRADE 4'` SLRb° ° FOOTER SEE a FOUNDATION em ,� FOR DETAILS MISSED 4 a 4. (� O 4 4 4 G' 4 4" SLAB a 14"x16" CONT. FOOTEF W/ (2) #5 REBAR W/ CORNER BENDS F7T P• F- b ICL J„T b. 5=,SA1—Q GRADE CF4 - - - a #5 FOOTER STEEL W/ _ - - 10" BEND IN FOOTER - � #5 FOOTER STEEL W/ 10" AAP ONNVERTBSTEELS ) BEND IN FOOTER AND MIN - 60 BAR (25") LAP ON VERT. - 4' SLAB.° - STEEL .. 4'4 SLAB' 4 ° 18"x16" CONT. GRADE a I FOOTER W/ (2) #5 � o � ° 4 18"x16" CONT. FOOTER REBAR W/ CORNER BENDS GRADE W/ (2) #5 REBAR W/ CORNER BENDS #5 FOOTER STEEL W/ 10" BEND IN FOOTER AND MIN 60 BAR (25") LAP ON VERT. STEEL SHOWER RECESS 4. h_ SLAB ° I ` 18"x16" CONT. FOOTER 1'-4" W/ (2) #5 REBAR W/ CORNER BENDS SHOWER RECESS_ SCALE: 3/4"=1'-0" 8" THICKENED EDGE W/ (1) #5 REBAR & CORNER BENDS I � a ° 4„ SLAB AO% FOOTER (4 SLAB Yl)�111�� � 1L �. 11L'�IIL�� l�E� ��1� 11L�� ���11L� SCALE. 34„=10„ II�2 SCALE: 3�4„=1,_®„ �3 SCALE: 3j4„=1,—®„ co / \\\X\ 100 I 7'-0" I 1 7'-o° I 3 0 F 3 S I. ' .. _,..,..� I � ..:......,..�..L ......1..:_�-------- �.:.....!_t............... ....,.. ! .;1. t....... _:..---- -------------------- j.:....1............:...1....1_!..,..1.. � I ....1.. _!..1.....1. I ........1..:.... _....._ E - r---------------------------------------------- � I I 1 S1 I I �- t I. -1 I I I / i I O I ' I 23 —0' 4_ _; I F 1 S1 2" ELECTRICAL CONDUIT � FOR ISLAND WIRING i EXACT LOCATION VERIFIED IN FIELD � •i 3 i MAIN SANITARY LINE y' I 0 � SEE Hl��EN FUN DEIAILS W I , 6" CONC SLAB W/ 6x6x1 .4 W.W.M. DOWEL ET• FOUNDATION PLAN SCALE: %4"=1'-0" 11=11-0" SCALE: 3j4„=V-0„ Revisions: No. Date Description Drawn: Issue Date: J.D. 09.26.2018 I.C.E.D. Services LLC. Independent Coordinators for Engineering &Drafting Services (352) 900-ICED Phone Jdiaz@ICEDServices.com Builder: 49=Devol5p■ 1081 SW Bianca Ave. Port Saint Lucie, FL (772) 828-9402 phone Lic #: CBC-1261264 Project: New Single Family Residence 11100 Carlton Rd. Port Saint Lucie, FL. St. Lucie County Sheet Title: Foundation and Beam Plans Sheet #: S1.0 Engineer: `i SOUTHEAST BUILDING ENGINEERS PE-64781 5911 Pescara Dr. Pace, FL 32571 772-774-90$6 phone TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE W/ SECTION 1609 OF THE 2017 FLORIDA BUILDING CODE 6TH ED. 1 � r nl (r Scott R. Sanders, REV. FL P.E. No. 64781 ROOF TRUSSES 2 X 4 DIAGCNAL BRACING 0 4'O.C. NAILED TO EACH TRUSS W/2-#16 112" MIN GYPSUM DRYWA-L 2"X4" RATRUN FOR DIAGONAL BRACING EXTENDING BACK 8' GABLE END BRACING SEE TYP. WALL SECTIONS FOR ROOFING SPECIFICATIONS 8D RINGSHANK NAILS @ 4" O.C. METAL DRIP EDGE I" X 6" CEDAR FASCIA 2" X 4" LADDER @ 24" O.C. ATTACHED @ BOTH ENDS WITH (2) 1On NAILS EACH END CONT. 2" X 4" SYP OR BETTER 3/8" PLYWOOD ATTACHED W/ (3) - 8D NAILS EVENLY SPACED @ EACH LADDER GABLE END TRUSS 12" O.H. ATTACH SHEATHING @ 6" O.C. / FIRST 3 TRUSSES 12" "LADDERED" SOFFIT DETAIL SCALE: 2" = V SEE LADDER SOFFIT DETAIL L-BRACE AS PER SCHEDULE 2-2" X 6" HEADER PER SCHEDULE 2"X4" BLOCKING @ 4'O.C. NAILED TO EACH TRUSS W/2-16D EXTEND BACK 8' GABLE END SHEATHING TO BE 112" CDX MIN. W/ 81) RINGSHANK NAILS @ 6" O.C. EDGES AND 12" O.C. FIELD TYP. TRUSS ANCHOR SEE SCHEDULE 8D NAILS @ 6" O.C. CONT. 2" X 4" SYP OR BETTER GABLE END TRUSS BRACING CHART TRUSS HEIGHT TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS--W/16D NAILS 8" U,C, VERTICAL STUD ON TRUSS F BRACING \ISTUD 2°x6" HEADER Ihn-E 2" X 4' DIAGONAL BRACE TOE -NAILED W/4-#16 TO HEADER L-BRACE NOT REQUIRED 0 TO 4'1' L-BRACE REQUIRED 4'2" TO 7'8' L-BRACE WITH HEADER 7'8" TO 14' GABLE HEADER SPACING L-BRACE WITH 2 HEADERS 14' TO 20' 1 HEADER PLACED AT CENTER OF TRUSS HEIGHT 2 HEADERS PLACED AT 1/3 AND 2/3 OF TRUSS HEIGHT i i i 2"X4" CONTINUOUS BLOCKING REQUIRED 4' UP FROM ROOF EDGE, NAILED W/ 2-16D @ EACH END. IST SHEETS FROM EDGES SHALL BE FULL 4'X 8' SHEETS. ROOF SHEATHING NAILED @ 3"O.C. ON SUBFASCIA AND AT 4" O.C. ON THE REMAINING EDGES.(BLOCKING MAY BE INSTALLED ON THE FLAT OR ON EDGE.) GABLE TRUSS BLOCKING REQUIREMENTS \ WALL SUPPORT \ \ SUB -FASCIA BOARD \ \ \ ROOF SHEATHING TO BE CARRIED BY 3 MEMBERS MINIMUM / / / CONNECTOR SCHEDULE (Simpson) Date: 9/262018 Notes: (1) Truss to block connections are mark'A' unless otherwise noted on layout.. Contractor. Above and beyond (2)Provide mark'A' at each vertical of Gable End Trusses to Bond Beam Owner: Stokes Truss MI Chambers Truss: Layout Date: 9/2012018 Engr. Date: 9/20/2018 --.._ ........ _._.. _.... _.. BRNC STRAP QTY'CONNECTOR FASTENERS CONNEGILLILEtvENTS ACTUAL'ALLOVV`. REMARKS ". Pi. ID ID UPLIFT UPLIFT d A 1 HETA 20 : (9) 14d x 1-1t2 1 Ply to Beam Block 1810 .... B 1 LLJS24 (4)10d x 1-112 mta_2'k blocking&(2) 10d nails l Ply to 2"x Blocking - 130 377 -..... _... into truss ...... .._.-_....... -._ TRUSS STRAPPING PLAN SCALE: %4"=1'-0" Revisions: No. Date Description Drawn: Issue Date: J.D. 09.26.2018 ;I I.C.E.D. Services LLC. Independent Coordinators for Engineering & Drafting Services (352) 900-ICED Phone Jdiaz@ICEDServices.com Builder: Above &Beyond Developing,lnc. 1081 SW Bianca Ave. Port Saint Lucie, FL (772) 828-9402 phone Lic #: CBC-1261264 Project: New Single Family Residence 11100 Carlton Rd. Port Saint Lucie, FL. St. Lucie County Sheet Title: Truss Strapping Layout Sheet #: S2.0 Engineer: EBE#z SOUTHEAST BUILDING ENGINEERS PE-64781 5911 Pescara Dr. Pace, FL 32571 772-774-9086 phone TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE W/ SECTION 1609 OF THE 2017 FLORIDA BUILDING CODE 6TH ED. I,- � /i Scott R. Sanders, P. . FL P.E. No. 64781 2" V.T.R. -11 TUB ------------------ --------- I II I 0x10 I --------- --------- ------ -. �W 17 I 0 CFM - op II I lOxLD 00 1 ---F -r------� 1Ox6 --- ----- -- 59 CFM V� I � � I� II ° i•I I I I I I I tOx6 129 CFM r--------- { - I!I ° C ° ___ 11 '+� /1 \J ,i A. H.U.I; Ili I ° i -}-- I}— , , o 6 --- x4 M 1Ox6 70 CFM 12x12 12 N S o • i•I I I `-----' I I II� 8x4 -- - - -�"j'--------------------'"--- 51 10x6 `-._. .-- ---- --—�_�-._ 110 CFM 15., -- -�---------------------------- -------- I 6' -_.____--------- -----------_-.----- - ---- ---------------- L - _._ ...---... 1000 10x10 --- —. li it Toxic L--� II 106 CFM 106 CFM 12x8 150 CFM I I — II II i --------- --- -------------- -------------- -------------- HVAC LAYOUT SCALE: %4"=1'-0" V.T.R. 4" TO APPROVED SANITARY SYSTEM SCALE: N.T.S. ELECTRICAL FIXTURE SCHEDULE SYM. DESCRIPTION LIGHT FIXTURE WALL M UN E LIGHT IXTURE n F.E. FLOOD LIGHT FIXTURE RECESSED LIGHT FIXTURE V VAPOR SEAL CHANDELIER FAN FIXTURE ® EXHAUST FAN/LIGHT FIXTURE ® EXHAUST FAN OARCI ARC FAULT RECEPTICLE �GFl GROUND FAULT RECEPTICALE WP WEATHER PROOF FIXTURE SWITCHED DUPLEX RECEPT. QUAD RECEPT. DUPLEX RECEPT. SINGLE DEDICATED RECEPT. 4 SWITCHED SINGLE RECEPT. 220V RECEPT. ® 220V DIRECT WIRE SO SMOKE DETECTOR W/ CARBON SWITCH $3 3 WAY SWITCH $4 4 WAY SWITCH $D DIMMER SWITCH 0 PUSH BUTTON ® T.V. CABLE OUTLET I CHIMES GARAGE DOOR SAFETY SWITCH A TELEPHONE OUTLET I FLOURESCENT FIXTURE ):====C WPC/ GFI ELECTRICAL LOAD CALCULATION 1436 SQ FT X 3 WATTS PER SQ FT 2 APPLIANCE CIR @ 1500 WATTS EACH 1 LAUNDRY CIR @ 1500 WATTS EACH 1 RANGE @ 8KW 2 DISWASHER AND DISPOSAL @ 1500 WATTS EACH 1 MICROWAVE @ 2000 WATTS 1 WATER HEATER @ 4.5 KW 1 DRYER @ 5 KW 1 REFRIGERATOR @ 1500 WATTS 2 BATHROOM @ 1500 WATTS EACH 6•I11-11:111I FIRST 10 KW @ 100% REMAINDER @ 40% A/C HEAT @ 100% rrn» 30323 WATTS DIVIDED BY 240 VOLTS = 126 AMPS USE 200 AMP SERVICE 4308 WATTS 3000 WATTS 1500 WATTS 8000 WATTS 3000 WATTS 4500 WATTS 5000 WATTS 1500 WATTS 3000 WATTS 35808 WATTS 10000 WATTS 10323 WATTS 10000 WATTS 30323 WATTS F.P.L. SERVICE (IF OVERHEAD) (3) #2/0 (THW) COPPER & (1) #4 GROUND (THW) COPPER IN 2" GALV. CONDUIT (3) #2/0 (THW) COPPER & (1) #4 GROUND (THW) COPPER IN 2" GALV. CONDUIT F.P.L. SERVICE (IF UNDERGROU r.m"o WALL (3) #2/0 (THW) COPPER & (1) #4 GROUND (THW) COPPER IN 2" GALV. CONDUIT 120/240 Volt A/C Condenser E.W.H. 1 $-3W 200 AMP 30 Circ. with Main Breaker #4 COPPER WIRE GROUND TO FOOTING STEEL, COPPER WATER PIPE, AND GROUND ROD ELECTRICAL SERVICE UNDER COUNTER FI FOR DISHWASHER d(P ----'---- -- - ------------------- GF 17 `. , Gq 0 0O _ -------- — illl------------- II I I LL CHAIN I ATTIC $p i _ GHT % ---- IF I v - WH N _ - - .---- - ° I ) o I Sp FI UGHT .I --- FAN I I A C ARCH � � --- ® RC � o FI ' lil FOR A.H.U. III; N ATTIC (PA -------------- .. ITI (—I I SD Z i Ilr --� J - SD I RC - I SD 11 i J I I I I• I -------- --- - -------------------------- (rGFI ' `\ (rGFI r I IW ELECTRICAL LAYOUT SCALE: %4"=1'—O" Revisions: No. Date Description Drawn: Issue Date: J.D. 09.26.2018 I I.C.E.D. Services LLC. Independent Coordinators for Engineering & Drafting Services (352) 900-ICED Phone Jdiaz@ICEDServices.com Builder: AlVYe &Be■ Developing, Inc. 1081 SW Bianca Ave. Port Saint Lucie, FL (772) 828-9402 phone Lic #: CBC-1261264 Project: New Single Family Residence 11100 Carlton Rd. Port Saint Lucie, FL. St. Lucie County Sheet Tltle. Electrical & HVAC Layout Sheet #: M1 .0 Engineer: ]SIGHT SIDE ELEVATION SCALE %4„=1'-0„ "5V" METAL ROOFING ATTACHED AS PER MFG. SPECS OVER (1) LAYER OF 30 LB FELT OVER OVER 1%2" PLYWOOD INSTALLED STAGGERED AND FASTENED TO PRE-ENGINEERED TRUSSES W/ 8D RINGSHANKS NAILS @ 6" O.C. @ EDGES AND 6" ON CENTER IN FIELD MTL. DRIP EDGE \-2"x6" FASCIA f 2'-0" STUCCO SOFFIT INSTALLED AS EXTERIOR CEILING DETAIL STUCCO SIDING J P17/iD VT1717Ar1,if)NT C- rATU 1/ff-1f nff c 4 3&6 R-30 S -%" CIELING DRYWALL MTL. STRAP SEE STRAP SCHEDULE FOR DETAILS DEL. COURSE OF BEAM BLOCK W/ (1) #5 CONT. REBAR W/ CORNER BENDS FILLED W/ 3000 PSI CONC EA. COURSE Y2" DRYWALL - #5 REBAR W/ 10" BEND IN BEAM IN FILLED CELL o W/ 3000 PSI CONC. 4'-0" O.C. MAX & ALL JAMBS, CORNERS, AND BENEATH GIRDER BEARING LOCATIONS 3/4" FOIL BACKED INSUL. OVER 1"x2" FURRING STRIPS @ 24" O.C. /- SEE SHEET S1 FOR FOOTER STEEL DETAILS WOOD BASE BOARD FLOOR COVERING TO BE I DETERMINED IN FIELD .I SEE SHEET 51 FOR FOOTER DETAILS ALL SECTION 3/ 59=1'-099 4 AREA SCHEDULE LIVING A/C 1,436 Sq Ft. FRONT PORCH 3M_SqFtj Sq Ft. Sq Ft. TOTAL 1,820 Sq Ft. C&C Vasd Wall Wind Pressures 160 C Risk Cat. II H<15 Ft. one 4 Interior Zone 5 Exterior SF = +33.5 / .36.3 E) 10 SF = +33.5 / -44.8 SF = +31.9 / -33.9 F) 20 SF = +31.9 / -41.1 SF = +29.9 / -32.7 G) 50 SF = +29.9 / -37.5 SF = +28.4 / -30.3 H)100 SF = +28.4 / -33.9 SF = +24.9 / -26.6 I)500 SF = +24.9 / -26.6 RoofC&C Pressures met: -25.3 Zone2:-53.4 Zone3:-78.8 ■ FRONT ELEVATION SCALE %4"=1'-019 ® is FOIL BACK FOIL BACK FOIL BACK INSULATION INSULATION INSULATION DOOR THRESHOLD FASTEN CBS BLOCK CBS BLOCK , 1%4" P.T. W/ TAPCONS AS PER WALL & LINTEL 1%2" P.T. WALL & LINTEL 1"x2" P.T. 1'x2" P.T. PRODUCT APPROVAL FURRING FURRING FURRING STRIP DOOR PANEL STRIP STRIP Y2„ Y2 • -- EXTERIOR DRYWALL EXTERIOR DRYWALL SIDING SIDING �- 1 "x4" P.T. 1 "x4" P.T. TAPCONS SEE IF 1 x P.T. BUCK PRODUCT APPROVAL 1 %4" P.T. USED THAN Y4"dx23/4" ATTACH P.T. DOOR AFFIDAVIT FOR TYPE WOOD BUCK TAPCONS THIRD DOOR c BUCK IN SUCH A CBS BLOCK AND SPACING FRAME AS PER MANNER AS TO, AS A WALL ATTACH P.T. DOOR BUCKS IN SUCH A MP PRODUCT SPECS Window Head (SEE PRODUCT APPROVAL AFFIDAVIT) MINIMUM, COVER THE AS A MINIMUM, COVER THE ENTIRE WIDTH ENTIRE WIDTH (AS EXTERIOR MEASURED FROM INSIDE TO OUTSIDE) OF SIDING AMB Y2" DRYWALL 1 %2" P.T. FURRING STRIP FOIL BACK INSULATION CBS BLOCK WALL MEASURED FROM DOOR J IF 2X P.T. BUCK INSIDE TO OUTSIDE) IF 1x P.T. BUCK USED THAN 1'4"oxV/4" TA USED THAN 3/16%34" OF PREHUNG DOOR DOOR FRAME AS PER PRODUCT SPECS 1 "x4' P.T. TAPCONS SPACED AS JAMB. APPROVAL AFFIDAVIT). r OP.T. PER PRODUCT IF 2X P.T. BUCK USED THAN 3/6"x3Y4" TAI WOOD BUCKI APPROVAL. / WOO TAPCONS SEE EXTERIOR PRODUCT APPROVAL SIDING AFFIDAVIT FOR TYPE AND SPACING Window Jamb AS PER PRODUCT APPROVAL. Door Head Door Jamb Note: All bucks to be flashed in c compliance with R703.6 as -l�lyn4�� listed on sheet Cl REVISf6 TYPICAL WINDOW AND DOOR DETAILS I Foy u�C PRE-ENG. TRUSSES WIRE LAT STUCCO WIRE LATH SHALL BE ATTACHED ACCORDING TO ONE OF THE FOLLOWING METHODS (FINAL METHOD TO BE DETERMINED IN FIELD): 1. DIAMOND -MESH EXPANDED METAL LATH, FLAT -RIB EXPANDED METAL LATH AND WIRE LATH SHALL BE ATTACHED TO HORIZONTAL WOOD FRAMING MEMBERS WITH 1Y2" ROOFING NAILS DRIVEN FLUSH WITH PLASTER BASE. (ASTM 7.10.2.2) 2. EXPANDED 3/8" RIB LATH SHALL BE ATTACHED TO HORIZONTAL WOOD FRAMING MEMBERS WITH NAILS OR STAPLES TO PROVIDE NOT LESS THAN 13/4" PENETRATION INTO WOOD FRAMING. (ASTM 7.10.2.3) WITH EITHER METHOD THE SPACING OF FASTENERS TO BE 7" O.C. ALONG SUPPORTS AS PER ASTM 7.10.2.1 AS PER ASTM 7.10.2.4 IF COMMON NAILS ARE USED THEY SHALL BE BENT OVER TO ENGAGE NOT LESS THE THREE STRANDS OF LATH, OR BE BENT OVER A RIB IF RIB LATH IS INSTALLED UCT APPRON' OPENING& I MODEL# I MANUFACTURER AdWWAVM" 23 SH Window 24 SH Egress Window Series 2461 34 SH Window 3080 Entry W/ 12" Sidelight 6080 Dbl, Door SH-5500 Eastern Architectual Systems GLASS Hi -Impact PGT Opaque Fiberglass Thermo Tru Corp, Door NIA 0 "I ATTACHMENT METHOD �XP."." - t 51GN TYPE, SIZE, SPACING &EM IE AT ESSURE 3116" Tapcons x Sufficient length t per( $ ccnc. Mtn 1-1/40@ Header: 6" from Comers and @ 21" Max O.C. FL14604:6-R7 +50.01-50.0 thereafter Jambes 6" from comers & @ 12" max O C. thereafter 1/4" Tapcons x Sufficient length to penetrate cono Min 1-1/4"@ 17-0630.05 Header: 12' from Comers and equally spaced 7130/20 *65.01-70.0 (2) above meeting rail & (3) Below meeting rail Jambs: (1) 12" from comers (2) total 114" Tapoons x Sufficient length to penetrate conc. Min 1-1/4"@ FL15037.3: +50.0/-50.0 Header: 3" & 6" from Corners and 3"&7" to each side of sldlight/door mullion Jambs: 6" from comers & @ 14.5" max O.C. 171.15037A +50.W-50.0 ATTACHMENT METHOD TYPE `"""' `" ""`�"" ' PRODUCT MODEL# MANUFACTURER EXPIRATION DESIGN SIZE, SPACING EMBEDMENT &STIFFENER ETC. DATE PRESSURE Gulf Coaa( Supply #9-16 Hex head wood screws w/ searing washer FL14645.3-R 74.8 Roofing "5V" Crimp & Manufacturing @ 16" O.C. along riff Soffit Stucco Siding Stucco 4'-8" 18'-0" 10 -8 _ 1 7'-4" - -- - w 08 24 SH EGRESS -------- _. .._- ------------------ WH -- -------- -®- -� - - l ' ---- ---- 4'-64„ --- D. W _� "6 I-' LAUNDRY - o 0 Ln d i KITCHEN 00 TO CABINET 10'-0" FLAT � I � O�O 10'-0" FLAT � FACE CEILING BEDROOM 1I CEILING j !L3 7� 1 12' 141" I 01 0 10FLAT J„ DINING - -- -;I 8'-1Oil' CEILING 3'-8 l 10-0FLAT I 14'-64 i CEILING is I0 W.I.C. 2680 M _ - i- PKT. r--- _ --------- MASTER o - o ---Fw--------j------; zI -------- --------�------- IBATH 1I 6'-2I '- _wa L____-------_1 m 10'-0" FAT CEILING u xC5Kl0I a---- ri a <BATH2 10D" FLAT M Y CEILING -li-N-- ---------------------------------------------- ---_-_------ --- -- ------ ..II -'MASTER '1 o GREAT BEDROOM _ BEDROOM #2 ; ; ROOM i o'-o"FAT CEILING 10'-0" FLAT in 10'-0" FLAT CEILING - CEILING 12'-14°' 2' '�44 20'-44" 14'-64" - o ,I II G 00 � - _ I1 1 I I ' . . -------------- . ---------- --- 34 SH --------- --- 3080 W/ -------------- 34 SH 34 SH I 1 EGRESS 12" SIDELIGHT EGRESS I i 4" 11'-8" 16'-8" 12'-4" I I I I II I I FRONT PORCH 10'-D" FLAT CEILING =====__________-------________ --------------------------------- ---_________________________-----m 16" 'l 6" 1 10'-4" 16" 10'-4" 16" 10'-4" 16" 10'-4" 16" 16" 50'-8" SCALE: n N v 0 I Ln I Revisions: No. Date Description Zj, 05.02.2019 In Field Revision Drawn: Issue Date: J. D. 09.25.2018 I I.C.E.D. Services L.L.C. Independent Coordinators for Engineering & Drafting Services (352) 900-ICED Phone Jdiaz@ICEDServices.com Builder: Devslopinp, InD, 1081 SW Bianca Ave. Port Saint Lucie, FL (772) 828-9402 phone Lic #: CBC-1261264 Project: New Single Family Residence 11100 Carlton Rd. Port Saint Lucie, FL. St. Lucie County Sheet Title: Floor Plan & Elevations Sheet #: Al .0 Engineer: 35£ { a vf4� SOUTHEAST BUILDING ENGINEERS PE-64781 5911 Pescara Dr. Pace, FL 32571 772-774-9086 phone TO THE BEST OF MY KNOWLEDGE, THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE W/ SECTION 1609 OFT E 2017 FLORIDA BUILDIN$'CO ,% H ED. `�4c gyV%b Coop Sco . anders, P.E. FL P.E. No. 64781 Ak ® Al►