HomeMy WebLinkAboutMISC LETTERSKMA Engineering & Surveying, LLC 80'Royal Palm Pointe, Suite 401 Vero Beach, FL 32960 May 28, 2020 SCANNED BY David Johnson St. Lucie County St Lucie County Building Department RE: AcquaVista Lot 3 - 4422 N. Hwy Al A' Permit No. 0 We have determined, based on worst —case conditions, the minimum number of concrete screw anchors required to withstand theshear, force applied to the wood buck for all windows and doors for the above referenced project. The force has been determined for each side of each window/door based on ASCE 7-10 with 170 MPH Vult, EXPOSURE D ENCLOSED, 30' MEAN HEIGHT, 5:12 PITCH, with Kd=0.85 using the ALLOWABLE STRESS DESIGN method. These values are representative of the minimum tributary area (10-sgft); the actual wind pressure for any component larger the 10-sgft would be less. t The shear tolerance for the anchors is based on 1/4"x3" TapCons (or equal) with a minimum one - inch (1 ") embedment into medium weight hollow block with a factor of safety of 4:1 (25% ultimate load values). Further load reductions have applied for less than nominal spacing and edge distance, in accordance with manufacturer recommendations. I do hereby certify that: • The fasteners used for the installation of all windows and doors for the above referenced project meet or exceed our requirements (as described above). • The number of fasteners used to secure all exterior windows and doors for the above referenced project meets or exceeds our calculated requirement for the buck attachment. • The attachment of the wood buck to the masonry via concrete screw anchor through the associated window frame,and into the masonry, in conjunction with our preceding certifications, is in accordance with FBC 2017 requirements: The following pages contain an accounting of all installed windows and doors, with the calculated wind force and fastener requirements. Noted on each is the actual number of fasteners installed. If you have any questions please do not hesitate to contact me. -06 David S. Knight, P.E. FL Reg. No. 41060 .M 9pY ^/ Q (1�(► \18-022\Lo��8r91C tl9197 4e �9-063;79 8-022 $ion Homes ref AQVSTA LOT 3 [-] GROUND FLOOR DOOR ATTACHMENT SCHEDULE MARK *MAXIMUM PRESSURE TRIBUTARY AREA TRIBUTARY AREA TOTAL FORCE **MINIMUM FASTENER COUNT per SIDE 001 PART OF ASSEMBLY WITH WINDOW 101 & 102 (see below) 002 GARAGE DOOR — INSTALL PER MANUFACTURER SPECIFICATIONS 003 —69.3 psf 5.00 SF 346.50 Ibs. I3*** OK 004 DOOR NOT EXPOSED (INTERNAL INSTALLATION) 005 —56.1 psf 5.25 SF 294.53 Ibs. 2*** NI 006 —56.1 psf 5.00 SF 280.50 Ibs. 2*** NI GROUND FLOOR WINDOW ATTACHMENT SCHEDULE ,MARK *MAXIMUM PRESSURE TRIBUTART AREAOTAL IBUTARY AREA FORCE **MINIMUM FASTENER COUNT per SIDE 1 —56.1 psf 18.00 SF 1,009.80 Ibs. 7*** OK 2 PART OF ASSEMBLY WITH WINDOW 1 -& DOOR 1 (see above) 3 —56.1 psf 5.50 SF 308.55 Ibs. 2*** OK 4 —56.1 psf 5.50 SF 308.55 Ibs. 2*** OK 5 —69.3 psf 5.50 SF 381.15 Ibs. 3*** OK 6 —56.1 psf 6.875 SF 385.69 Ibs. 3*** OK 7 —56.1 psf 4.00 SF 224.40 Ibs. 2*** OK *BASED ON A5CE 7-10 with 170 MPH Vult, EXPOSURE D ENCLOSED, 30' MEAN HEIGHT, 5: 1 2 PITCH, with Kd=0.65 using the ALLOWABLE STRESS DE51GN method. THESE VALUES ARE REPRESENTATIVE OF THE MINIMUM ALLOWABLE TRIBUTARY AREA (TEN SQUARE -FEET), AND 50 ARE HIGHER THAN THE ACTUAL PRESSURE ON THE COMPONENT. "FASTENER 5HEARTOLERANCE HAS BEEN BASED ON 114" CONCRETE SCREW ANCHORS (TAPCON or equal) WITH A MINIMUM ONE -INCH (I") EMBEDDMENT INTO MEDIUM WEIGHT HOLLOW BLOCK WITH A 4: 1 FACTOR OF SAFETY (25% ULTIMATE LOAD). FURTHER LOAD REDUCTIONS HAVE BEEN APPLIED FOR LE55 THAT NOMINAL SPACING AND EDGE DISTANCE, TO GIVE A WORKING ALLOWABLE LOAD OF I G2 Ib5. PER ANCHOR. a MINIMUM OF TWO (2) ANCHORS IS REQUIRE4,FOR EACH SIDE: 'ADDITIONAL FASTENERS MAY BE REQUIRED PER MANUFACTURER SPECIFICATIONS. CONTRACTOR SHALL REFER TO THE APPROPRIATE NOA OR APPROVAL PRIOR TO INSTALLATION. M = MULLION IN WINDOW ASSEMBLY NI = NOT IN5ATLLED AT THE TIME OF THIS ENGINEER'S INSPECTION. OK = INSTALLATION OF THE WOOD BUCK FORTHI5 COMPONENT 15 ADEQUATE. .18-022 AQVSTA LOT 3 r m N O (D CD OP, t' c0+ M 0 0 01 D� s � �m 09 mo c� o� O p Olew m�• a �m m�y p � m Ia tz R Now IN m ®o e B 1 ST FLOOR DOOR ATTACHMENT SCHEDULE MARK *MAXIMUM PRESSURE TRIBUTARY AREA TRIBUTARY AREA TOTAL FORCE **MINIMUM FASTENER COUNT per SIDE 101 -56.1 psf 24.75 SF 1,388.48 Ibs. 9*** OK 102 -56.1 psf 20.25 SF 1,136.03 Ibs. 7*** OK 103 -42.1 psf^ 37.50 SF 2,103.75 Ibs. 10*** OK 104 -56.1 psf 14.90 SF 835.89 Ibs. 6*** OK 105 -42.1 psf^ 50.00 SF 2,805.00 Ibs. 13*** OK 106 -69.3 psf 30.00 SF 1,683.00 Ibs. 11*** OK 1 SIT 1=LOOR WINDOW ATTACHMENT. SCHEDULE MARK *MAXIMUM PRESSURE TRIBUTARY AREA TRIBUTARY AREA TOTAL FORCE **MINIMUM FASTENER COUNT per SIDE 101 -56.1 psf 1.50 SF 84.15 lbs. 2*** OK 102 -56.1 psf 1:50 SF 84.15 Ibs.' a 2*** OK 103 -56.1 psf 3.125 SF 175.31 Ibs. 2*** OK 104 -69.3 psf 2.50 SF 173.25 Ibs. 2*** OK 105 -56.1 psf 2.50 SF 140.25 Ibs. 2*** OK 106 -56.1 psf 2.50 SF 140.25 Ibs. 2*** OK 107 -56.1 psf 2.50 SF 140.25 Ibs. 2*** OK 108 -56.1 psf 2.50 SF 140.25 Ibs. 2*** OK 109 -56.1 psf 8.00 SF 448.80 Ibs. 3*** OK 110 -69.3 psf 3.33 SF 230.77 Ibs. 2*** OK 'BASED ON ASCE 7-10 with 170 MPH Vult, EXPOSURE D ENCLOSED, 30' MEAN HEIGHT, 5: 1 2 PITCH, with Kd=0.85 using the ALLOWABLE STRESS DE51GN method. THESE VALUES ARE REPRESENTATIVE OF THE MINIMUM ALLOWABLE TP113UTAPY AREA (TEN SQUARE -FEET), AND 50 ARE HIGHER THAN THE ACTUALPRE55URE ON THE COMPONENT. -FASTENER SHEAR TOLERANCE HAS BEEN BASED ON 114" CONCRETE SCREW ANCHORS (TAPCON or equal) WITH A MINIMUM ONE -INCH (I") EMBEDDMENT INTO MEDIUM WEIGHT HOLLOW BLOCK WITH A 4: 1 FACTOR OF SAFETY (25% ULTIMATE LOAD). FURTHER LOAD REDUCTIONS HAVE BEEN APPLIED FOF, _LE55 THAT NOMINAL 5PACING.AND EDGE DISTANCE, TO. GIVEA WORKING ALLOWABLE LOAD OF I,G2 Ibs. PER. ANCHOR. a MINIMUM,OF TWO (2) ANCHORS 15 REQUIRED FOR EACH. SIDE. ADDITIONAL FASTENERS MAY BE REQUIRED PER MANUFACTURER .5PECIFICATIONS. CONTRACTOR SHALL REFER TO THE APPROPRIATE NOA OR APPROVAL PRIOR TO INSTALLATION. ^ MAXIMUM PRESSURE ON LARGE OPENINGS (100 sgft OR GREATER) HAVE REDUCED VELOCITY PRESSURES IN ACCORDANCE WITH A5CE 7-10. M = MULLION IN WINDOW ASSEMBLY NI = NOT IN5ATLLED AT THE TIME OF TH15 ENGINEER'S INSPECTION. OK = INSTALLATION OF THE WOOD BUCK FORTHIS COMPONENT 15 ADEQUATE. 8-022 Sian Homes ref AauaVsta\Drowinas\Structural\Lot 3\18-022 AOVSTA LOT 3 r*�a, 0 0 0 coy C cn t•+• w G' r, (D 0 O (~D t7 CZ O 0 o'$CD 4 p I to .a 09 1 a mCIO mt bd a q po '9N� �o 0 0 2nd FLOOR DOOR ATTACHMENT SCHEDULE MARK *MAXIMUM PRESSURE TRIBUTARY AREA TRIBUTARY AREA TOTAL FORCE **MINIMUM FASTENER COUNT per SIDE 201 -56.1 psf 16.00 SF 897.60 lbs. 6*** OK 202 -56.1 psf 16.00 SF 897.60 lbs. 6*** OK 2nd FLOOR WINDOW ATTACHMENT SCHEDULE MARK *MAXIMUM PRESSURE TRIBUTARY AREA TRIBUTARY AREA TOTAL FORCE **MINIMUM FASTENER• COUNT .per SIDE 201 -69.3 psf 6.67 SF 462.23 lbs. 3*** OK 202 -56,1., psf, 18.00 SF 1,009.80 lbs. 7*** OK 203 SINGLE ASSEMBLY w/ WINDOW 202 204 205 -69.3 psf 6.25 SF 433.125 lbs. 3*** OK 206 -69.3 psf 2.50 SF 173.25 lbs. 2*** OK 207 -56.1 psf 7.50 SF 430.75 lbs. 3*** M OK 208 -56.1 psf 2.50 SF 140.25 lbs. 2*** OK 209 -69.3 psf 1.50 SF 103.95 lbs. 2*** OK 210 -69.3 psf 2.25 SF 155.93 lbs. 2*** OK 211 -56.1 psf 2.25 SF 126.23 lbs. 2*** OK 'BASED ON A5CE 7-10 with 170 MPH Vult, EXP05URE D ENCLOSED, 30' MEAN HEIGHT, 5: 1 2 PITCH, with Kd=0.85 u5lncy the ALLOWABLE 5TRE55' DE51GN method. THESE VALUES ARE REPRESENTATIVE OF THE MINIMUM ALLOWABLE TRIBUTARY AREA (TEN 5QUARE-FEET), AND 50 ARE HIGHER THAN THE ACTUALPRE55UPE ON THE COMPONENT. "FASTENER 5HEAR TOLERANCE HAS BEEN BA5ED ON 1/4" CONCRETE SCREW ANCHORS (TAPCON or equal) WITH A MINIMUM ONE -INCH (I") EMBEDDMENT INTO MEDIUM WEIGHT HOLLOW BLOCK WITH A 4: 1 FACTOR Of 5APETY (25% ULTIMATE LOAD). FURTHERLOAD REDUCTION5 HAVE BEEN APPLIED FOR LE55 THAT NOMINAL SPACING AND EDGE 715TANCE; TO GIVE A WORKING ALLOWABLE LOAD OF I G2 Ib5. PER ANCHOR. a MINIMUM OF TWO (2) ANCHOR5 15 REQUIRED FOR.EACH SIDE. -ADDITIONAL FA5TENER5 MAY BE REQUIRED PER MANUFACTURER SPECIFICATIONS. CONTRACTOR 5HALL REFER TO THE APPROPRIATE NOA OR APPROVAL PRIOR TO I1\15TALLATION. M = MULLION IN WINDOW ASSEMBLY NI = NOT IN5ATLLED AT THE TIME OF TH15 ENGINEER'S INSPECTION. OK = IN5TALLATION OF THE WOOD BUCK FOR THI5 COMPONENT 15 ADEQUATE. 0 < KMA Engineering & Surveying, LLC 8Q Roya],Pylm Pointe; Suite 401 Vero Beach, FL. 32960 "(772) 509-5505. May 13, 2020 David Johnson - -St Lucie -County Building Department SCANNED RE: AcquaVPermit No.Iat of 30 4322 N.. Hwy A1A St. Lucie COunty do hereby certify that: • That the front steps have been constructed in accordance with all applicable FBC 2017 standards. They have been constructed as a frangible element; with hollow- tinreinforced masonry retaining -walls on frangible footers (12"x16") and with a soil - supported slab saw cut to no larger than 5'x5'. These are in accordance with FDEP and FEMA guidelines, and are not structurally connected to the main residence. If you have any questions please do not hesitate to contact me. David S. Knight, P.E. FL Reg.. No. %41060 \18-9-Ult a 191c &29M 100319 McGuire & Associates, Inc. Vero Beach, FL 32960 MAR 2 0 2019 Phone: (772) 569-5505 Fax: (772) 569-1455 ST. Lucie County, Pern Letter of Transmittal To: JPI,-Inc, (Andrew) from: David Knight, P.E. Address: St. Lucie County Date: 20-Mar-19 SCAnt.,_ RE: Aquavista Lot 3 Job No. 18-022 06 Cng� CC: Permit # 1901-0543 WE ARE SENDING YOU X�Attached Under Separate Cover Via the following items: Shop Drawings Prints DCopy of Letter OSpecificationE OPlans DChange Order 2 Pyramid Hood Specs 2 Smart Vent Specs 2 Smart Vent Installation 2 Napoleon Fire Place Specs 2 Napoleon Fire Place Installation 2 lGeotechnical Reports 2 Structural Plan Sets 2 Site Plan 1 Response Letter 2 Elevator Specs 2 Architectural Package THESE ARE TRANSMITTED For Approval For Your Use F—]Foir Review / Comment DAs Requested Approved as Submitted Returned for Corrections Comments m ight, McGuire &Associates, Inc. Consulting Engineers and Planners 80 Royal Palm Pointe, Suite 401 Vero Beach, Florida 32960 Scott B. McGuire, P.E. March 20, 2019 Planning & Development Department Building & Code Regulation Division St. Lucie County 2300 Virginia Avenue Ft. Pierce, FL 34982 RE: AcquaVista Lot 2 (a.k.a. Queen Island Preserve, Block A, Lot 2) PERMIT #1901-0541 --P hon e:4T72)569-5505 Fax: (772) 569-1455 RECEIVED MAR 2 0 ''019 ST. Lucle County, Permitting In response to comment(s) for the above stated project (dated February 21, 2019), been made to the plans (comments in italics; responses in bold). PLEASE NOTE have been addressed under a separate cover. SCANNED BY St. Lucie County the following changes have : Zoning Review comments • 1) PLEASE UPDATE TO THE CURRENT BUILDING CODE EDITION- SITE DRAINAGE PLAN. (FAC. 61G20-1.001 (1)) ACKNOWLEDGED. Sheet 2of5 from the FDEP CCCL Plan Set has been updated. • 2) FLOOD ZONES ON THE HORIZONTAL CONTROL PLAN DOES NOT MATCH THE SURVEY. ACKNOWLEDGED. FDEP CCCL Horizontal Control Plan (sheet lof5) has been updated. • 3) STRUCTURAL PLANS STATE DRAWINGS ARE NOT FOR CONSTRUCTION WITHOUT CONSTRUCTION STAMP. ([A] 1,07.2.1). ACKNOWLEDGED. Structural Plans are now stamped "CONSTRUCTION SET". • 4) STAIRWELL FRAMING PLANS ARE INCOMPLETE. ([A] 107.2.1) ACKNOWLEDGED. Refer to sheet S-12 for structural framing details. Refer to Architectural sheet A8001 for interior stairway details. • 5) NO DETAILS HAVE BEEN PROVIDED FOR THE INTERIOR STAIRS. ([A] 107.2.1) Addressed by Architect. Refer to Architectural sheet A8001 for interior stairway details. • . 6) EXHAUST FAN IS MISSING FROM CABANA BATH. (M1507.4) Addressed by Architect. An exhaust fan has been included on Architectural Sheet E201. • 7) PLEASE REVIEW THE POWER RECEPTACLE SPACING & REVISE PER SECTION (E3901). Addressed by Architect. Architectural sheets E201 and E202 have been updated in accordance with FBC Electrical E3901. • 8) PLEASE LABEL THE ARC FAULT & GFC1 CIRCUITS. (E3902) Addressed by Architect. Refer to sheets E101 ELECTRICAL NOTES, GENERAL #12 for Arc -Fault note. GFI receptacles are labeled on the electrical plans sheets E201 and E202. • 9) PROVIDE SPECIFICATIONS FOR FLOOR SHEATHING & ATTACHMENT. ([A] 107.2.1) ACKNOWLEDGED. Wall sections (sheets S-7, S-8, & S-10) include specifications for sub - flooring attachment. AND by Architect... Refer to TYPICAL WALL SECTIONS sheetA801; plans call for 314" T&G plywood glued & screwed to floor trusses. • 10) PROVIDE SPECIFICATIONS FOR ROOF SHEATHING & ATTACHMENT. ([A] 107.2.1) ACKNOWLEDGED. Refer to sheet S-7, S-8, & S-10, all BU/LD/NGANALL SECTION(s) address attachment of roof sheathing to wood trusses. Architectural sheet A801 has detailed -- 0.a^Ar^Mf1A"0 Mr funs of m�thr" • 11) PLEASE PROVIDE ATTACHMENT FOR EXTERIOR RAILING. ([A] 107.2.1. Addressed by Architect. Attachment details for railing added to Architectural Sheet A801. • 12) CONCRETE SPECIFICATIONS ON THE ARCHITECTURAL AND STRUCTURAL DRAWINGS ARE IN CONFLICT, REVISE AS NEEDED. ([A] 107.2.1). ACKNOWLEDGED. Specifications on Structural -Plans are correct.- Architectural Sheet A001-hasbeen-updated. - • 13) PLEASE PROVIDE CUT SHEETS FOR THE FLOOD VENT. ([A] 107.2.1). ACKNOWLEDGED. Flood vent cut sheets have been included with this submittal. • 14) PROVIDE CUT SHEETS FORA) EXHAUST HOOD AT COOKTOP, B) FIREPLACE, C) ELEVATOR. ([A] 107.2.1) ACKNOWLEDGED. Cut sheets have been included with this submittal. • 15) PLEASE PROVIDE THE R-VALUE FOR INSULATIONAT CEILING OVER GARAGE. ([A] 107.2.1) Addressed by Architect. R-Value for garage ceiling has been added to Architectural Sheet A200. • 16) CARBON MONOXIDE DETECTORS REQUIRED (R315.1) Addressed by Architect. Carbon Monoxide detectors are called out on Architectural Sheet E101 under Smoke Detector Notes #3. • 17) PLEASE PROVIDE VAPOR BARRIER & TERMITE TREATMENT. (R318.1). ACKNOWLEDGED. Refer to sheet S-3 for general call -out of vapor barrier and termite treatment below frangible slabs; further denotation can be found on individual foundation details of sheet S-9, as well as the building/wall sections on sheets S-7, S-8, & S-10. • 18) PLEASE PROVIDE THE GEOTECHNICAL REPORT WITH FOUNDATION RECOMMENDATIONS. (R401.1). ACKNOWLEDGED. Geotechnical Report has been included with this submittal. • 19) THE MULLION PRODUCTAPPROVAL 17-1212.24 /S EXPIRED, THEALUMINUM SWING DOOR 17-1212.09 IS EXPIRED. (R609.1). Addressed by Architect. Product approvals for mullions and aluminum swing'door have been updated. • 20) PLEASE PROVIDE ATTIC ACCESS. (R807.1). ACKNOWLEDGED. Attic access included on sheets A201, A202, E201, & E202 of the Architectural Plans. Attic Access included, per Architect revision; refer to sheet S-6 of the Structural Plans. • 21) PLEASE PROVIDE A 'CONSTRUCTION DRAWINGS' FLOOD ELEVATION CERTIFICATE. (3109.1.3). Elevation Certificate, in accordance with FBC 3109.1.3, shall be provided upon completion of the LHSM, prior to further vertical development. • 22) (3109.4) FOLLOWING DOCUMENTATION SHALL BE PREPARED, SIGNED, AND SEALED BYA QUALIFIED FLORIDA-REGISTERED PROFESSIONAL ENGINEER AND SUBMITTED TO THE BUILDING OFFICIAL- FOR SHEAR WALLS, THE CERTIFICATIONS REQUIRED IN SECTION (3109.3.2) ACKNOWLEDGED. Refer to sheet S-3; sections of shearwall footing (grade beam) have been removed from the under the front entry adjacent to the elevator shaft, as they are unnecessary. This will improve the flow of water through the superstructure in the event of catastrophic flooding. All East-West shreawalls are within 20-degrees of shore normal. The total length of shore -parallel shearwall as,a projection on the shoreline is less than the allowed 20% of the shore -parallel building projection. An exception to section 3109.3.2.2 shall not be 2 required. PLEASE NOTE: The certification that you are referring to only applies to low rise structures. • 23) (1612.52 2.2). CONSTRUCTION DOCUMENTS SHALL INCLUDE STATEMENT THAT THE tiulLDIMMS-DESIGNED-INACCORDANCE-WITH ASCE-24-, iNCLUDING-THAT-THE-PILE OR COLUMN FOUNDATION AND BUILDING OR STRUCTURE TO BE ATTACHED THERETO IS DESIGNED TO BEANCHORED TO RESIST FLOTATION, COLLAPSEAND LATERAL MOVEMENT DUE TO THE EFFECTS OF WIND AND FLOOD LOADS ACTING SIMULTANEOUSLY ON ALL BUILDING COMPONENTS, AND OTHER LOAD REQUIREMENTS OF CHAPTER 16. ACKNOWLEDGED. The structure has been designed in accordance with Florida Building Code and the ASCE 24, with all applicable considerations with regard to Chapter 16 loads in conjunction with_windlwater loads. ANote has been added _on -Shoot -S-1 _under FOUNDATION NOTES #7. 24) (1612.52 2.3). FOR BREAKAWAY WALLS DESIGNED TO HAVE RESISTANCE OF MORE THAN 20 PSF DETERMINED USING ALLOWABLE STRESS DESIGN, CONSTRUCTION DOCUMENTS SHALL INCLUDE STATEMENT THAT THE BREAKAWAY WALL IS DESIGNED IN ACCORDANCE WITH ASCE 24. ACKNOWLEDGED. Frangible (breakaway) walls have been designed in accordance with the ASCE 24, the Florida Building Code, and FEMA recommendations. A note has been added on sheet S-1 under MASONRY NOTES #11. • 25) (R322.3.6) THE CONSTRUCTION DOCUMENTS SHALL INCLUDE DOCUMENTATION THAT IS PREPARED AND SEALED BYA REGISTERED DESIGN PROFESSIONAL THAT THE DESIGN AND METHODS OF CONSTRUCTION TO BE USED MEET THE APPLICABLE CRITERIA OF THIS SECTION (FLOOD RESISTANT CONSTRUCTION). Addressed by Architect. Documentation regarding flood resistant construction is included on Architectural Sheets A200, A303, A801, & E201. 26) (R322.3.4) WHERE WIND LOADING VALUES OF THIS CODE EXCEED 20 POUNDS PER SQUARE FOOT, AS DETERMINED USING ALLOWABLE STRESS DESIGN, THE CONSTRUCTION DOCUMENTS SHALL INCLUDE DOCUMENTATION PREPARED AND SEALED BYA REGISTERED DESIGN PROFESSIONAL THAT (4.1.) THE WALLS AND PARTITIONS BELOW THE DESIGN FLOOD ELEVATION HAVE BEEN DESIGNED TO COLLAPSE FROM A WATER LOAD LESS THAN THAT WHICH WOULD OCCUR DURING THE BASE FLOOD. (4.2.) THE ELEVATED PORTION OF THE BUILDING AND SUPPORTING FOUNDATION SYSTEM HAVE BEEN DESIGNED TO WITHSTAND THE EFFECTS OF WIND AND FLOOD LOADS ACTING SIMULTANEOUSLY ON STRUCTURAL AND NONSTRUCTURAL BUILDING COMPONENTS. ACKNOWLEDGED. Frangible walls have been designed in accordance with FBC requirements and ASCE 24 guidelines, in conjunction with FEMA recommendations. A Note has been added on Sheet S-1 under GENERAL NOTES #11 & #12. 27) PLEASE CLEARLY IDENTIFY THE LOCATION OFALL FRANGIBLE WALLS AND SLABS ON THE FOUNDATION PLAN, REQUIRED PER (R322.3.2, R322.3.4, 3109.3.4). ACKNOWLEDGED. All slabs below the DFE are intended to be frangible; a note has been added to sheet S-3 to reflect this. Further callouts have been added through the slab plan (sheet S-3). it had been noted on sheet S-4 (bottom -left) that all masonry walls below the DFE are to be frangible, as well as a designation for masonry shearwalls; further call -outs have been added to clarify (sheet S-4). • 28) ELECTRICAL, MECHANICAL AND PLUMBING SYSTEM COMPONENTS ARE NOT TO BE MOUNTED ON OR PENETRATE THROUGH WALLS THAT ARE DESIGNED TO BREAK AWAY UNDER FLOOD LOADS. (R322.3.4). Addressed by Architect. Notes regarding MEP components have been added and electrical plan has been modified; refer to Architectural Sheet E201. • 29) IN AREAS OF SHALLOW FLOODING (AO ZONES), BUILDINGS AND STRUCTURES SHALL HAVE THE LOWEST FLOOR (INCLUDING BASEMENT) ELEVATED TO A HEIGHT ABOVE THE 3 HIGHEST ADJACENT GRADE OF NOT LESS THAN THE DEPTH NUMBER SPECIFIED IN FEET (MM) ON THE FIRM PLUS 1 FOOT (R322.2.1). ACKNOWLEDGED. Habitable space, as defined in the FBC, is restricted to the first & second floors. The use of enclosed spaces below the DFE has been defined on Architectural Sheet A200. • 30) ENCLOSED AREAS BELOW THE DESIGN FLOOD ELEVATION SHALL BE USED SOLELY FOR PARKING OF VEHICLES, BUILDING ACCESS OR STORAGE. (R322.3.5). ACKNOWLEDGED. Habitable space, as defined in the FBC, is restricted to the first & second floors. The use of enclosed spaces below the DFE has been defined on Architectural Sheet A200. • 31) ENSURE ELEVATOR CONTROLS SHALL COMPLY WITH (3109.3.4). Addressed by Architect. Elevator control note added to -Architectural Sheet A200._ 32) SEE (R322.3.5.1) PROTECTION OF BUILDING ENVELOPE. AN EXTERIOR DOOR THAT MEETS THE REQUIREMENTS OF SECTION R609 SHALL BE INSTALLED AT THE TOP OF STAIRS THAT PROVIDE ACCESS TO THE BUILDING AND THAT ARE ENCLOSED WITH WALLS DESIGNED TO BREAKAWAY IN ACCORDANCE WITH SECTION R322.3.4. Per discussions with building officials, it has been determined that the proposed home does not lie in a Coastal A Zone, and is thus not required to meet the design standards as outlined in section R322.3 of the FBC. 33)'ENGINEER TO CLARIFY- THE TRUSSES ARE DESIGNED FOR AN ENCLOSEDBUILDING. THE BUILDING COULD POTENTIALLY BE OPENED IN A WIND/FLOOD EVENT WHEN GROUND LEVEL WALLS BREAKAWAYCREATING AN OPEN/PARTIALLY ENCLOSED BUILDING. CLARIFICATION. The house has been designed as an enclosed building, in accordance with Florida Building Code. The collapse of frangible elements of the building shall not have a noticeable impact the function of the roof system. ZONING COMMENTS 31712019 Comment: ELEVATION PAGE REQUIRED TO INDICATE THE LOBBYAREA AT 14.1'. The FBC allows for enclosed spaces below the base flood elevation, if those areas are designed in accordance with the ASCE 24 and (for structures east of the Coastal Control Line) FBC 3109 and FBC R322. The enclosed areas below the base flood elevation are intended to be used solely for vehicle parking (garage), storage, and building access (lobby). All of these enclosed areas shall have flood vents, in accordance with the ASCE and FBC. Please do not hesitate to contact me if you have any questions. We appreciate your considerations and your timely review of our resubmittal. Sincerely, -16 David S. Knight, P.E.