Loading...
HomeMy WebLinkAboutELEVATION REPORTVTRINITYIERD I'APPENDIX1: ATTACHMENT REQUIREMENTS FOR WIND UPDFT RESISTANCE - _ (' Table Deck Application Type Description Page 1A Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 2 113 Wood New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 2 1C-1 Wood New or Reroof (Tear -Oft) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 2 1C-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 3 1D Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 3 The following notes apply to the systems outlined herein: - 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: OMG $112 or #14 HD with OMG 3 in. Galvalume Steel Plate (non -ribbed) or Tru-Fast DP or HD with Trufast 3" Metal Insulation Plates. Minimum''/< -inch plywood penetration or minimum 1-inch wood plank embedment. 3. Unless otherwise noted, insulation maybe anyone layer or combination of polyisocyanumte, polystyrene, wood fiberboard, perlite or gypsum -based roof board that meets the OA requirements of F.A.C. Rule 61G20- 3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk" carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5. For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 6. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Stanard TAS 105. 7. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing In accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 orTesting Application Standard TAS 124. 8. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads m P a 2 nC7 t,, n J Q < m co T Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report T39820.12.11-R3 for FL9487-RS Certi/icote of Authorization #9503 bra EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017 Prepared by: Robert Nieminen, PE-59166 LeakBarrier• EasyStick'" Modified Bitumen Roof Systems, (254) 913-7750 Appendix 1, Page 1 of 3 �,TRINITY ERD TABLEIA: WOOD DECKS —NEW CONSTRUCTION; REROOF (Tear -Off) or RECOVER. SYSTEM TYPE C: 'MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER '� i System Top Insulation Layer Roof Cover MDP No. Deck (Note 1) Base Insulation Layer (Psf) Type Fasteners Attach Base Ply Ply Cap W-1' Min. 15/32" plywood (Optional) One or more layers, Min. 3/8-Inch SECUROCK Gypsum- Note 2 1 per 1 h r EasyBase (Optional) EasyBase EasyStick Plus -52.5 at max. 24" spans any combination, loose laid Fiber Roof Board W 2 Min. 15/32" plywood (Optional) One or more layers, Min. 2-inch ACFoam II, EnergyGuard Poly iso, ENRGY 3, H-Shield, ISO 95+ Note 2 PEasyBase 1 per 1 hr (Optional) EasyBase EasyStick Plus -82.5 at max. 24" spans any combination, loose laid GL or Multi -Max FA3 TABLE 1B: WOOD DECKS— NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPED: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Insulation Layer Base Sheet Roof Cover MDP No. Deck (Note 1) Type Attach Type Fasteners Attach Base Ply Cap (psf) W-3. Min. 15/32" plywood Any type, thickness or Loose laid EasyLay Note 2 10-Inch o.c. in the min. 4-Inch lap and 10-inch o.c. One or two plies, EasyStick Plus -60.0 at max. 24" spans combination in two (2), equally spaced, staggered center rows EasyBase WA Min. 15/32" plywood Any type, thickness or Loose laid EasyLay Note 2 8-inch o.c. in the min. 4-Inch lap and 8-inch o.c. in One or two plies, EasyStick Plus -135.0 at max. 24" spans combination four (4), equally spaced, staggered center rows EasyBase W-5. Min. 15/32" plywood Any type, thickness or Loose laid EasyNailBase Nate 2 6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in One or two plies, EasyStick Plus -135.0 at max. 24" spans combination four (4), equally spaced, staggered center rows EasyBase TABLE IC-1: WOOD DECKS —NEW CONSTRUCTION or REROOF (Tear -Off) t - + i _ SYSTEM TYPE E:NON-INSULATED, MECHANICALLY ATTACHED BASE ISHEET .(nails)„ BONDED ROOF COVER System Base Sheet Roof Cover MDP No. Deck (Note 1) Type Fasteners Attach Base Ply Cap (Psfl W 6' Min. 19/32" plywood EasyLay 12 ga. annular ring shank nails and min. 32 ga.,1-5/8" 7-inch o.c. in the4-inch lap and 7-inch o.c. in three One or two plies, EasyStick Plus -60.0 at max. 24"spans diameter tin -caps. (Ref: FBC1517.5) (3), equally spaced, staggered center rows EasyBase W 7 Min. 15/32" plywood EasyLay Simplex MA%X Cap Fastener 8-inch o.c. in the min. 4-inch lap and 8-inch o.c. in One or two plies, EasyStick Plus -82.5 at max. 24" spans four (4), equally spaced, staggered center rows EasyBase W-8. Min. 15/32" plywood EasyLay 12 ga. annular ring shank nails and min. 32 ga., 1-5/8" 4-inch o.c. in the 4-inch lap and 4-inch o.c. in four One or two plies, EasyStick Plus -120.0 at max. 24" spans diameter tin -caps. (Ref: FBC 1517.5) (4), equally spaced, staggered center rows EasyBase W-9' Min. 15/32"plywood EasyNailBase 12 ga. annular ring shank nails and min. 32 ga.,1-5/8" 4-inch o.c. in the 4-Inch lap and 4-inch o.c. in five One or two plies, EasyStick Plus -120.0 at max. 24" spans diameter [in -caps. (Ref: FBC 1517.5) (5), equally spaced, staggered center rows EasyBase Exterior Research and Design, U.C. d/b/a Trinity] ERD Evaluation Report T39820.12.11-R3 for FL9487-RS Certificate ofAuthor¢ation n9503 6rx EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017 Prepared by: Robert Nieminen, PE-59166 LeakBarrier• EasyStick'" Modified Bitumen Roof Systems; (2541 913-7750 Appendix 1, Page 2 of 3 VTRINITYIERD TABLE.SC-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER '.. SYSTEMTYPE'E: NON-INSULATED,MECHANICALLYATTACHED BASE SHEET(screws.& plates), BONDED ROOF. COVER System Deck (Note I) Base Sheet Roof Cover MDP No. Type Fasteners Attach Base Ply Cap (psf) W-30. Min. 15/32" plywood Eas La y y Note 2 10-inch o.c. in the min. 4-inch lap and 10-inch o.c. in two (2), equally spaced, One or two plies, at max. 24" spans staggered center rows EaryBase EasyStick Plus -60.0 W-11. Min. 15/32" plywood Ea La sy y Note 2 8-inch o.c in the min. 4-inch lap and 8-inch o.c. in four (4), equally spaced, One or two plies, EasyStick Plus -135.0 at max. 24" spans staggered center rows EaryBase W 12 MIn.11/32"plywood Eas NailBase y Note 2 6-Inch o.c. in the min. 4-inch lap and 6-inch o.c. in four (4), equally spaced, One or two plies, EasyStick Plus -135.0 at max. 24" spans staggered center rows EaryBase R TABLE ID: WOOD DECKS- NEW CONSTRUCTION orREROOF(Tear-Off), _ SYSTEM TYPE F: BONDED ROOF COVER System Deck (Note 11 Roof Cover MOP No. Type Joint Treatment Base Ply Ply cap (psf) W-13. Min. 15/32" plywood at max. 24" spans None (OpBase (Optional) Ea sy (Optional) Easyease EasyStick Plus -75.0 W 14. Min. 15/32"plywood Plywood joints are covered with 4-inch wide strips of EaryBase, rolled into (Optional) EaryBase (Optional) EaryBase EasyStick Plus -120.0 at max. 24" spans place to create continuous bond. Exterior Research and Design, U.C. d/b/a Trinity) ERD Evaluation Report T39820.12.11-R3 for FI9487-RS CertiArote ofAuthori2ation #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017 Prepared by: Robert Niernmen, PE-59166 LeakBarfler® EasyStick'" Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 3 of 3