I'APPENDIX1: ATTACHMENT REQUIREMENTS FOR WIND UPDFT RESISTANCE - _ ('
Table Deck Application Type Description Page
1A Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 2
113 Wood New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 2
1C-1 Wood New or Reroof (Tear -Oft) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 2
1C-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 3
1D Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 3
The following notes apply to the systems outlined herein: -
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: OMG $112 or #14 HD with OMG 3 in. Galvalume Steel Plate (non -ribbed) or Tru-Fast DP or HD with Trufast 3" Metal Insulation Plates. Minimum''/< -inch plywood penetration or minimum
1-inch wood plank embedment.
3. Unless otherwise noted, insulation maybe anyone layer or combination of polyisocyanumte, polystyrene, wood fiberboard, perlite or gypsum -based roof board that meets the OA requirements of F.A.C. Rule 61G20-
3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk" carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5. For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted.
6. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Stanard TAS 105.
7. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing In accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 orTesting Application Standard TAS 124.
8. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads m
P a 2
nC7 t,, n
J Q < m co
T
Exterior Research and Design, U.C. d/b/a Trinity IERD Evaluation Report T39820.12.11-R3 for FL9487-RS
Certi/icote of Authorization #9503 bra EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017
Prepared by: Robert Nieminen, PE-59166 LeakBarrier• EasyStick'" Modified Bitumen Roof Systems, (254) 913-7750 Appendix 1, Page 1 of 3
�,TRINITY ERD
TABLEIA: WOOD DECKS —NEW CONSTRUCTION; REROOF (Tear -Off) or RECOVER.
SYSTEM TYPE C: 'MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER '� i
System
Top Insulation Layer
Roof Cover
MDP
No.
Deck (Note 1)
Base Insulation Layer
(Psf)
Type
Fasteners
Attach
Base Ply
Ply
Cap
W-1'
Min. 15/32" plywood
(Optional) One or more layers,
Min. 3/8-Inch SECUROCK Gypsum-
Note 2
1 per 1 h r
EasyBase
(Optional) EasyBase
EasyStick Plus
-52.5
at max. 24" spans
any combination, loose laid
Fiber Roof Board
W 2
Min. 15/32" plywood
(Optional) One or more layers,
Min. 2-inch ACFoam II, EnergyGuard
Poly iso, ENRGY 3, H-Shield, ISO 95+
Note 2
PEasyBase
1 per 1 hr
(Optional) EasyBase
EasyStick Plus
-82.5
at max. 24" spans
any combination, loose laid
GL or Multi -Max FA3
TABLE 1B: WOOD DECKS— NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPED: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
Insulation Layer
Base Sheet
Roof Cover
MDP
No.
Deck (Note 1)
Type
Attach
Type
Fasteners
Attach
Base Ply
Cap
(psf)
W-3.
Min. 15/32" plywood
Any type, thickness or
Loose laid
EasyLay
Note 2
10-Inch o.c. in the min. 4-Inch lap and 10-inch o.c.
One or two plies,
EasyStick Plus
-60.0
at max. 24" spans
combination
in two (2), equally spaced, staggered center rows
EasyBase
WA
Min. 15/32" plywood
Any type, thickness or
Loose laid
EasyLay
Note 2
8-inch o.c. in the min. 4-Inch lap and 8-inch o.c. in
One or two plies,
EasyStick Plus
-135.0
at max. 24" spans
combination
four (4), equally spaced, staggered center rows
EasyBase
W-5.
Min. 15/32" plywood
Any type, thickness or
Loose laid
EasyNailBase
Nate 2
6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in
One or two plies,
EasyStick Plus
-135.0
at max. 24" spans
combination
four (4), equally spaced, staggered center rows
EasyBase
TABLE IC-1: WOOD DECKS —NEW CONSTRUCTION or REROOF (Tear -Off) t - +
i
_ SYSTEM TYPE E:NON-INSULATED, MECHANICALLY ATTACHED BASE ISHEET .(nails)„ BONDED ROOF COVER
System
Base Sheet
Roof Cover
MDP
No.
Deck (Note 1)
Type
Fasteners
Attach
Base Ply
Cap
(Psfl
W 6'
Min. 19/32" plywood
EasyLay
12 ga. annular ring shank nails and min. 32 ga.,1-5/8"
7-inch o.c. in the4-inch lap and 7-inch o.c. in three
One or two plies,
EasyStick Plus
-60.0
at max. 24"spans
diameter tin -caps. (Ref: FBC1517.5)
(3), equally spaced, staggered center rows
EasyBase
W 7
Min. 15/32" plywood
EasyLay
Simplex MA%X Cap Fastener
8-inch o.c. in the min. 4-inch lap and 8-inch o.c. in
One or two plies,
EasyStick Plus
-82.5
at max. 24" spans
four (4), equally spaced, staggered center rows
EasyBase
W-8.
Min. 15/32" plywood
EasyLay
12 ga. annular ring shank nails and min. 32 ga., 1-5/8"
4-inch o.c. in the 4-inch lap and 4-inch o.c. in four
One or two plies,
EasyStick Plus
-120.0
at max. 24" spans
diameter tin -caps. (Ref: FBC 1517.5)
(4), equally spaced, staggered center rows
EasyBase
W-9'
Min. 15/32"plywood
EasyNailBase
12 ga. annular ring shank nails and min. 32 ga.,1-5/8"
4-inch o.c. in the 4-Inch lap and 4-inch o.c. in five
One or two plies,
EasyStick Plus
-120.0
at max. 24" spans
diameter [in -caps. (Ref: FBC 1517.5)
(5), equally spaced, staggered center rows
EasyBase
Exterior Research and Design, U.C. d/b/a Trinity] ERD Evaluation Report T39820.12.11-R3 for FL9487-RS
Certificate ofAuthor¢ation n9503 6rx EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017
Prepared by: Robert Nieminen, PE-59166 LeakBarrier• EasyStick'" Modified Bitumen Roof Systems; (2541 913-7750 Appendix 1, Page 2 of 3
VTRINITYIERD
TABLE.SC-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
'.. SYSTEMTYPE'E: NON-INSULATED,MECHANICALLYATTACHED BASE SHEET(screws.& plates), BONDED ROOF. COVER
System
Deck (Note I)
Base Sheet
Roof Cover
MDP
No.
Type
Fasteners
Attach
Base Ply
Cap
(psf)
W-30.
Min. 15/32" plywood
Eas La
y y
Note 2
10-inch o.c. in the min. 4-inch lap and 10-inch o.c. in two (2), equally spaced,
One or two plies,
at max. 24" spans
staggered center rows
EaryBase
EasyStick Plus
-60.0
W-11.
Min. 15/32" plywood
Ea La
sy y
Note 2
8-inch o.c in the min. 4-inch lap and 8-inch o.c. in four (4), equally spaced,
One or two plies,
EasyStick Plus
-135.0
at max. 24" spans
staggered center rows
EaryBase
W 12
MIn.11/32"plywood
Eas NailBase
y
Note 2
6-Inch o.c. in the min. 4-inch lap and 6-inch o.c. in four (4), equally spaced,
One or two plies,
EasyStick Plus
-135.0
at max. 24" spans
staggered center rows
EaryBase
R TABLE ID: WOOD DECKS- NEW CONSTRUCTION orREROOF(Tear-Off),
_ SYSTEM TYPE F: BONDED ROOF COVER
System
Deck (Note 11
Roof Cover
MOP
No.
Type
Joint Treatment
Base Ply
Ply
cap
(psf)
W-13.
Min. 15/32" plywood
at max. 24" spans
None
(OpBase
(Optional) Ea sy
(Optional) Easyease
EasyStick Plus
-75.0
W 14.
Min. 15/32"plywood
Plywood joints are covered with 4-inch wide strips of EaryBase, rolled into
(Optional) EaryBase
(Optional) EaryBase
EasyStick Plus
-120.0
at max. 24" spans
place to create continuous bond.
Exterior Research and Design, U.C. d/b/a Trinity) ERD Evaluation Report T39820.12.11-R3 for FI9487-RS
CertiArote ofAuthori2ation #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017
Prepared by: Robert Niernmen, PE-59166 LeakBarfler® EasyStick'" Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 3 of 3