Loading...
HomeMy WebLinkAboutMOBILE HOME INSPECTION REPORTSt Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce. FL 34982 Ktt-C:sv ` FILE COPY-��a,-��8� JAN 2 S 2049 ST. Lucie County, Permitting Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. SCANNED BY All used Mobile homes must be Wind Zone II certified. r8ft Lucie County Owner: WYNN 8L-D& (,Opp Date: 1119 S�ANrs{-t-ftKFS) / (Print or type) Address: 1396 9 CN CAN7T'APV Ford P1 ERCE . FL( FAI RWAY5 WIP) pp hysical Locafion of Home)[ FH3 & to y 9 9 FLA 393 S2 2 ( Year / Manufacturer r/ V F-terial # & 3 jg j f)Y?98 HUD Plate #�U 323 S.23 Width_ Length Single 1 Double Wind Zone�� C = In Compliance N = Not in Compliance Fire Safety / Electrical _ 1. Smoke Detector: Installed Missing 2. Electrical System Checked: Exposed Wiring _Other_ 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_ Unplugged Opening Other_ C 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire_ GFCI receptacles not where required_ G5. Electrical Ground: Chassis Main Panel Gas Pipe acviscd 319i05 Page I of 3 Construction C 1. Exit Doors Operable: Front Back Other 2. Exit Door Locks: Missing Inoperable 1_ 3. Egress windows: Missing Inoperable C_4. Windows: Broken Glass Inoperable r 5. Screens: Missing Damaged 6. Floor System: Joist Decking Area Damaged 7. Interior Paneling: Missing_ Loose —Damaged 8. Rodent Proofing: Bottom Board —Pipe openings —Other 9. Leaks Apparent: Ceiling _ Doors _ Floor _ Roof 10. Vertical tie -down straps: Missing _ Short _ Damaged_ 11. Structural modifications since manufactured: YES_ NO-V-/- _r__ 12. Walls: Structurally Unsound _ Loose _ Weather tight Plumbing C_ 1. Trap: Missing Not connected Other r 2. Plumbing fixtures: Missing _ Not installed _ Not Vented _' 3. Relief Valve: Missing Inoperable Other C 4. Drain Waste and Venting Piping: Missing Not supported_ Clean outs _ Use of fittings Not capped_ Heating and Air Conditioning r 1. Heating Appliances: Missing Not Connected Other 2. Deleted Heating/AC system: Not installed Other C_ 3. Thermostat: Missing Inoperable __C_ 4. Air registers: Missing Inoperable --C_ 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 6. Gas furnace Water heater vent: Missing 7. Return Air: To Furnace To A/C 8. Range: Vent Hood Loose From rooms 9. Gas Valve: Accessible Installed improperly L_ 10. Gas lines: Not capped Not supported Kinked Notbonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or eteriorated? YES NO� 2. Will a remodeling permit be required? YES NO The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and fife safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX Date inspected: it/ I h 9 Inspected By: U J 06X CC: _,__ Slgn rb7b-73a Phone Number: (�(�//w�) THEIR SEAL. License# 3`t`3j8 Page 3 of 3 EnggrsSea) STEVEN G. WOOD, P.E. FL LICENSE 34398 960 SULTAN DR It MT ST LUCIE, FL