HomeMy WebLinkAboutPRODUCT APPROVALS2/11/2019 Florida Building Code Online ~ ` Business1 1 Rquiation p BQS Home 1og In I User Registrallon j Hot Topics Submit Sumharge scats ItFacts Publications Contact Us BCISSne Map Unks I Search d b a *Product Approval USER: Public User pr Wa. Pmduct Auomval Menu > Peuduetw9auT Umo. S , > Pamrmsdrt WSQ> Application Detail FL # FL5822-R2 Application Type Revision" Code Version 2010 Application Status Approved Comments Archived Product Manufacturer Smart Vent Products, Inc. Address/Phone/Email 430 Andbro Dr Unit 1 Pitman, NJ 08071 (877)441-8368 Info@smartvent.com Authorized Signature Michael Graham Info@smartvent.com Technical Representative Michael J. Graham Address/Phone/Email 20 Warrick Ave. Glassboro, NJ, NJ 08028 (888) 628-4115 mike@smartvent.com Quality Assurance Representative Address/Phone/Email SCANNED BY St. Lucie County Category Structural Components Subcategory Products Introduced as a Result of New Technology Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer + Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Alexis Spyrou Evaluation Report Florida License PE-68101 Quality Assurance Entity Architectural Testing, Inc., an Intertek Company Quality Assurance Contract Expiration Date 12/31/2015 Validated By Locke Bowden P.E. + Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL5822 R2 COI COI Smart Vent signed and cert.odf ._ .Sections from_the Code. _ _ _ _ ___.__.. 1612.5(1)(1.2) 1714.2 2/11/2019 Florida Building Code Online Product Approval kmi-6d Method 2 Option B "- - Date Submitted 12/15/2011 Date Validated 12/16/2011 —Date -Pending -FBC—Approval— 12/22/2011 Date Approved 01/31/2012 Date Revised 02/26/2015 FL # Model, Number or Name Description 5822.1 Model #1540-510 SmartVent Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 Other: One vent may be used for up to 200 sq. ft, of interior space. Installation Instructions PTID Sm II lfms✓_18aU= IInshOffmM529 Verified By: Alexis Spyrou Florida PE 68101 Created by Independent Third Party: Yes Evaluation Reports FL5822 R2 AE PER 1550 signed and tert updated odf FL5822 R2 AE SmartVent - impact Requirements Letter 12.Y5 11. signed Aad cert.pdf Created by Independent Third Party: Yes 15822.2 1 Model #1540-514 1 SmartVent Overhead Door Model Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 Other: One vent may be used for up to 200 sq. ft. of interior space. 5822.3 1 Model #1540-520 Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100. Other: One vent may be used for up to 200 sq. ft. of interior space. Installation Instructions FL5822 R2 TI Installation Instructions.lid Verified By: Alexis Spyrou Florida PE 68101 Created by Independent Third Party: Yes Evaluation Reports FL5822 R2 AE PER 1550 signed and cart u ja ed df FL5822 RZ AE SmartVent - Impact Requirements Letter 12,15.11 signed and cert.pdf Created by Independent Third Party: Yes FloodVent Installation Instructions FL582Z R2 II Installation Inctructionc_pdf Verified By: Alexis Spyrou Florida PE 68101 Created by Independent Third Party: Yes Evaluation Reports FL5822 R2 AE PER 1550 signed and cart uptlated.odf FL5822 R2 AE SmartVent- Impact Requirements Letter 12,15.11 signed and cert.pdf Created by Independent Third Party: Yes 15822.4 1 Model #1540-524 1 FloodVent Overhead Door Model Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 Other: One vent may be used for up to 200 sq. ft. of interior space. Installation Instructions FL5822 R2 II Installation Instructions.odf Verified By: Alexis Spyrou Florida PE 68101 Created by Independent Third Party: Yes Evaluation Reports FL5822 R2 AE PER 1550 signed and cert updated. odf FL5822 R2 AE ImpactSmartVent -Reauirement5 Letter 12 I5.11 signed and cert.pd Created by Independent Third Party: Yes 15822.5 1 Model #1540-570 1 Wood Wall FloodVent Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 Other: One vent may be used for up to 200 sq. ft. of interior space. Installation Instructions FL5822 R2 II Installation Instructions.pdf Verified By: Alexis Spyrou Florida PE 68101 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: Yes 15822.6 1 Model #1540-574 1 Wood Wall FloodVent Overhead Door Model Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +100/-100 Other: One vent may be used for up to 200 sq. ft. of Interior space. ansca uavon-ansvucuons- -- ---- - ------ — FL5822 R2 II Instailation Instructions.odf Verified By: Alexis Spyrou Florida PE 68101 Created by Independent Third Party: Yes Evaluation Reports FL5822 R2 AE PER 1550 signed and cart uoda[ed.odf FL5822 R2 AE SmartVent - Impact Requirements Letter 2111/2019 Florida Building Code Online 12,M fled and cert.odf Create_.-_, idependent Third Party: Yes Back KE' Coma Us:: 2601 Blair Stare Read, Tallahassee FL 32399 Phone: 850487-1824 The State of Florida Is an Aq/EE0 employer. _Ccyryght 2007-2013 State of Florida.:: Pdvacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant W Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official communication with the Icensee. However email addresses are public record. it you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, F.S., please dick hem product Approval Accepts ® � ® ® M 4 SMI rlt Y}I hTAI C..' BUILDING DROPS 127w.FairbS4 uiteks 8 Suite 38 A Perfect Solution in Every Drop Winter Park, Fl. 32789 Certificate of Authorization: 29578 407.644.6957 PH 407:644:2366-FX contact@buildingdrops.com November 28, 2031 TO: Mr. Mike Graham President Smart Vent Products, Inc. 430 Andbro Dr. Unit 1 Pitman, NJ 08071 FROM: Alexis Spyrou, P.E. Building Drops, Inc. RE: PRODUCT NAME: FloodVent— Impact Requirements Dear Mr. Graham, The purpose of this letter is to evaluate the impact (wind-borne debris) requirements for your FloodVENT product, according to the Florida Building Code (FBC) 2007 & 2010, International Building Code (IBC), International Residential Code (IRC), and ASCE 7 engineering standards. According to the FBC Section 1626.1(c), all parts of the building envelope protection shall meet impact test criteria except for vents in a garage with four or fewer cars. The size of the vent is not to exceed the minimum required design area by more than 25%. The typical FloodVENT opening size, as indicated by the manufacturer, is 15.25" x 5", or 0.53 square feet (sf). Typically two vents are installed per wall, which provides a total net open area of 1.06 sf per installation. The total net open area provided by the vents is regarded as insignificant such that the openings do not compromise the enclosure category of the structure. An enclosed building is one defined as not partially enclosed and not open. An open building is defined as a building with each wall being at least 80% open. A garage with flood vents does not fall within the definition of an open building. A partially enclosed building is defined as a building that complies with both of the following: 1. The total area of openings in a wall that receives positive external pressure exceeds the sum of the areas of openings in the balance of the building envelope (walls and roof) by more than 30%. 2. The total area of openings in a wall that receives positive external pressure exceeds 4 sf or 1% of the area of that wall, whichever is smaller, and the percentage of openings in the balance of the building envelope does not exceed 20 percent. Page 1 of 2 BUILDING DROPS 127w.FairbS4 uite8 Suite 38 A Perfect Solution in Every Drop Winter Park, FL 32789 certificate of Authorization: 29578 407.644.6957 PH contact@buildingdrops.com A standard garage wall is approximately 25 feet long by 8 feet tall. This equals an approximate wall area of 200 sf. The typical net open area for two flood vents, as described above, is 1.06 sf, which is less than 4 sf and less than 1% of the wall area. It can also be assumed that 1.06 sf does not exceed more than 10% of the remaining open areas of the garage. Therefore, a garage with flood vents cannot be considered a partially enclosed building. In my professional opinion, the flood vents manufactured by SmartVent Products, Inc. do not require additional impact (wind-borne debris) protection devices to be placed over them so that they can continue functioning as flood vents. The vents do not increase the amount of openings in a wall or building such that the building classification changes from enclosed to partially enclosed. In addition, the 2010 FBC has specified applicable governing authorities to establish special flood hazard areas as per FEMA specification under 2010 FBC section 1622.3. This product has been evaluated, dependent to specific site conditions, to meet the minimum requirements of the National Flood Insurance Program (NFIP) flood plain management requirements (44 CFR) with respect to flood openings for enclosed areas for the purpose of equalizing hydrostatic pressure resulting from flooding. The product has been evaluated to conform to design principles noted in Section 2.6.2.2 of ASCE 24 for a maximum rate of rise and fall of 5.0 feet per hour by the ]CC - ES under evaluation report ESR-2074. Thus, the product may be used in wall construction to comply with 2010 FBC Section 1612.5(1)(1.2). Please feel free to contact me should you have any questions regarding this evaluation. liStilBest Regards, ,,ssoeeX1S"S?yR��i,- �cE^'sF - ALEX SPYROU Alexis Spyrou, P.E. �O FL PE No. 68101 ---, Building Drops, Inc. FBPE Cert. of Authorization No. 407.644.6957 No * 2011.12,15 TE OF C N Al E��p 08:25:51-05'00' Page 2 of 2 1. PREPARE HOLE 2. INSERT FRAME IN HOLE IN WALL 3. BENDS RAPS TO WALL THICKNESS 4. PLACE STRAPS BEHINDI WALL AND PUSH TANGS INTO - SLOTS IN FRAME INSTALL DOOR INTO FRAME. �\ FRAMED WALL INSTALLATION SHOWN \ STANDARD 16" O.C. STUD MUST BE i \ CUT AND AN 8" X 16" HOLE FRAMED WITH AN ADJACENT DUMMY STUD. L \ \ 1611 I'M \ \ "- W ' X U = SQFT i 4 W 8" 3 \ 12" '\ MAX /01 QFT / 200 = # OF VENTS REQUIRED (MINIMUM 2) IUALLY SPACE AROUND ALL PERIMETER WALLS BE USED FOR THE CERTIFIED SMART VENT® AND FLOODVENT tm � \ 55 VENT' T' Go 106 the flow" 888-628-41 '1 5 I ,b AUTOMATIC COVER ROWBWU .. VENT EOUfP 01 AS MANUACRRED BY'SLIARTVEBI' RISULAIED MOOR 1510-/10 NOTES: APPLY f INSTALL INSTALL INSURE INSURE SIAIN1 55 STEEL FIRE RATED SOLUTION - FLOOD VENT WITH FIRE RATED DAMPER INSTALLATION INSTRUCTIONS 1' `I iVI t. ELEVATION wxl SHOWN all '11PE E' PRM BO MIN fum lea W I m sEa RE wm sHm TOP AND WHOM ELEVATION USING 3/8 LUNG SS RAT READ SET METAL S m STAINLESS STEEL SLEEVE AS MANUFACIUNEB BY'SMARIVENT' SIEVE MODEL I540-531 TYPE 'E' FIRE —RATED FLOW THRU VENT > . p p ' J SCALE: 3' = 1'-0' IE RATED CAULK AROUND SLEEVE THEN SCREW DAMPER IN FOUR PLACES BOTH TOP AND BOTTOM - USE 3/8" MAX. LONG SCREWS - SLEEVE INTO 16 1/4 X 81/4 ROUGH OPENING ALL VOIDS WITH FIRE RATED CAULK FLOODVENT INTO OPPOSITE SIDE OF OPENING USING ADHESIVE iLEEVE COVERS ANY INNER BLOCK OPENINGS $Mart VENT® UOD VENT DOES NOT COME IN CONTACT WITH ARE DAMPER .WHILE BEING ROTATED FULLY IN BOTH DIRECTIONS 888-6284115 YOUR LOCAL BUILDING CODE FOR SPECIFIC ARE CODE REGULATIONS WWWAMAlw4cm.aoM IRATE ENT•dwn WISH ALTERNATE STRAP LOCATIONS I ON SIDI 2—D' 3—D' Smart VENT® BLOCK OR POURED INSTALLATION INSTRUCTIONS. r 1b-1/4' KUUUH UVLNINU 10 V ,o :S e 15-1/4' OPEN 0 0 i e oQEN s �werr o P (u ST I.ti AN of AT EXTERIOR VIEW DOUR EXTERIOR REMOVED�� > > p o—C I p- -I.' 0 0 -- --------ll-A 8-1/4' HIGH X 16-1/4' WIDE ROUGH OPENING FRAME DOOR OPEN — -- — --- DOOR SHOWN OPEN FRAME ' > IN FRAME > RAPS GO BEHIND WALL M112 D CAN BE BROKEN OFF SLOTS TO AVOID + STRUCTIONS ' ' > FINAL GRADE SIDE SECTION VIEW "repare a C EAN 16-1/4' wide by 8-1/4' high rough opening for each vent, (1 block wide x I block high) with the ottom of the hole no more then 12' above finished grade. 2. Measure wail thickness and bend (more than 90°) 4 straps at nearest slot to the measurement from pointed end, 3. Remove door from frame. (turn upside down, rotate bottom of door outward and slide out of slots) 4. Insert two itraps Into two top sets of slots in frame from rear. After pushing teeth through rear set slots, ONLY PUSH STRAPS ONE CLICK INTO FRONT SLOTS, Straps should have bent legs pointing up, 5. Caulk may be applied behind front frame flange. Tilt frame so top goes Into wall opening first with strap legs going behind wall above opening,, Push frame Into opening so front flange Is tight to face of wall. 6. Reach through frame opening and Install two bent straps through two bottom sets of slots In frame, trapping wall between front flange and bent strap, Squeeze all straps tight. Frame should be flush to wall face and secure, 7. Check that frame Is square and slots are clear of debris, mortar and caulk, 8. Install door Into frame by grasping bottom of door (with plastic pins) and front (with smaller squares) facing up. Slide door Into frame such that metal pins on each side slide Into slots on sides of frame, Let the door slide down following tie path of the slots, until they are at the bottom of the slots In the dimples. 9. Let the bot tom of the door go so that the door rotates down into the frame. Check that door Is latched on both sides, INTERIOR SUPPER STRAPS BEHIND WALL ALTERNATE SIDE STRAPS BEHIND WALL 2'x 15-1/4' OPEN 3'x 15-1/4' OPEN BOTTOM STRAPS BEHIND WALL Smart VENT® 888-628 4115 W W W.SMARTVENT.COM ALTERNATE STRAPS LOCATIONS IN STIES 2 PLS. OVERLAP ONE VENT FLANGE OVER THE SILICONE JOINT \ OPEN Smart VENT® BLOCK OR POURED SIDE BY SIDE INSTALLATION INSTRUCTIONS LINTEL IS REQUIRED PER LOCAL BUILDING CODE TOUGH OPENING 33 EXTERIOR VIEW — DRILL AND INSTALL 2 SS SHEETMETAL SCREWS EXTERIOR INTERIOR ° DOOR ' > > ' > UPPER STRAPS ® ° REMOVED�� > > > BEHIND WALL > ALTERNATE DETAIL 'C' ..�"' � �> >> SIDE STRBEHINDAPS y../ TUGH ENING 8 1/4' OQ� DOOR "'• a OPEN FRAME BOTTOM STRAPS > BEHIND WALL L 12' MAX >> STRAPS GII BEHIND WALL , > AND CAN BE BROKEN OFF AT SLOTS TO AVOID > Prepare a CLEAN 33 ' wide by 8-1/4' high rough opening for each vent (2 block wide x I block high) —" A with the bottom of the hole no more then 12' above finished grade. Measure wall thickness and bend (more than 90') 8 straps at nearest slot to the measurement from pointed end. Remove door from frame. (turn upside down, rotate bottom of door outward and slide out of slots) Insert four straps Into two top sets of slots In frame from rear. After pushing teeth through rear set slots, ONLY PUSH STRAPS ONE CLICK INTO FRONT SLOTS. Straps should have bent legs pointing up. With the two outside vent frames sandwiched together drill and screw the two frames together with 2 SS sheet metal screws. Caulk or adhesive may be applied behind front frame flange. Tilt frame so top goes Into wall opening first with strop legs going behind wall above opening. Push frame Into opening so front flange Is tight to face of wall. Reach through frame opening and Install two bent straps through two bottom sets of slots In frame, trapping wall between front flange and bent strap. Squeeze all straps tight. Frame should be flush to wall face and secure. Check that frame Is square and slots are clear of debris, mortar and caulk. Install door Into frame by grasping bottom of door (with plastic pins down) and the word 'TOP' facing up, Slide door Into Prone such that metal pins an each side slide Into slots an sides of frame. Let the door sUde down following the path of the slots, until they are at the bottom of the slots In the dimples, Let the bottom of the door go so that the door rotates down Into the frame, Check that door Is latched on both sides, Insert two thin blades or cards Into the float slots and unlatch the door to Insure free functionality, then latch again. SIDE SECTION VIEW Smart VENT® 877-441 8368 W W W.SMARTVENT.COM Smart VENT® BLOCK OR POURED SIDE 1 SIDE WITH INSIDE SLEEVE aNSTALLATIC INSTRUCTIONS ❑NE VENT FLANGE ❑VER THE ❑THER, JOINT 10 peEN 2%WW DOOR SHOWN OPEN IN FRAME OUGH ❑PENING 33 EXTERIOR VIEW DRILL AND INSTALL 2 SS SHEETMETAL SCREWS IVA VeEN -LWW 0 DETAIL 'C' DOOR REMOVED 8 1/4' DOOR —� OPEN —r FRAME 12" 1, Prepar'e a CLEAN 33 ' wide by 8-1/4' high rough opening for each vent (2 block wide x 1 block high) with the bottom of the hole no more then 12' above finished grade, 2, Remove door from frame, (turn upside down, rotate bottom of door outward and slide out of slots) 3. Dry f1i the frames in place making sure there are no obstructions and that the front flange sits against the flat outside wall. Inser,t the inner sleeve from the inside of the building through the opening and over the vent frame, 4. With the two outside vent frames sandwiched together drill and screw the two frames together with 2 SS sheet metal screws SIDE SRAPS BEHIND .. .epare a CL with the be 2. Measure wall 3. Remove door<_ 4. Assemble two Place top 1 front of f 5. Insert 2 str slots, ONL 6. Chalk may be a .the top strc 7. Reach throe hanging di 8. Install a sl the wall c 9. Make sure I 10, Hold doors fi letting me 16-1/4' ROUGH SMART VENT @ STACKING INSTRUCTIONS MODELS 1540-511 AND 1540-521 UPPER FRAME :NSTALL 2 ;CREWS FDETAIL 'C' `LOWER FRAME OpE111 DOOR SHOWN BEING '14INSERTED INTO FRAME EXTERIOR VIq,yI `STRAPS GO BEHIND WALL AND UU CAN BE BROKEN OFF AT SLOTS TO AVOID OBSTRUCTIONS 8 PLS UPPER TOP VENT \ EXSERI� WITHIN 12 LOWER FRAME +> > LEA DETAIL 'A' UPPER STRAPS BEHIND WALL SIDE STRAPS BEHIND WALL INTERIOR BOTTOM STRAPS BEHIND > WALL E +> > DETAIL 'B' NYLON SNAP -IN SPACER 2 PLCS SIDE SECTION VIEW :AN 16-1/4' wide by 16-3/8' high hole for each set of two stacking vents (1 block wide x 2 blocks high) ttom of the hole no more then 3,5' above finished grade. thickness and overbend (more than 90') 8 straps at nearest slot to the measurement from pointed end. from frames. (turn upside down, rotate bottom of door outward and slide out of slots) frames together using two nylon spacers snapped Into holes In rear of frames as shown In Detail 'B'. ^ame (one with short bottom flange) over and In front of bottom frame (one with short top flange) and Fasten ames together with two self tapping screws as shown In Details 'A' and 'C'. Do not over tighten screws, .ps Into top slots of TOP frame. Straps should have bent legs pointing up. After pushing teeth through rear ' PUSH STRAPS ONE CLICK INTO FRONT SLOTS, they will be tightened later In Installation, )plied to back of flanges for a better seal to wall face. Place frame assembly Into wall opening by sliding )s behind wall and resting frame bottom on bottom of wall opening. Press flanges tight to wall face. gh bottom frame opening and Install two bent straps Into two bottom slots with the bent legs of the straps wn behind wall and trapping wall between front flange and bent strap. Squeeze tight to wall. ,ap on each side of both frame openings as shown In Detail 'D', Install with bent leg pointing outward behind id Into slots on each of upper sides. Squeeze tight to wall. Now, squeeze top frame straps tight to watt, oth frames are flush to wall face, secure, square, level and all slots are clear ofdebris, mortar and caulk. on the bottom, parallel to ground with back facing ground and re -Install Into frames by Inserting top first and :at pins find slots. Push all way back and allow door to drop and rotate down and both sides latch closed. Smart VENT@ 888-628 4115 ulosioa SCREW Smart VENT OVERHEAD DOOR INSTALLATION INSTRUCTIONS 2' OPEN 3' OPEN — 15-1/4" OPEN nncnm u® oc m � m n w0unw u.s. EXTERIOR VIEW —i I6-3/4' I6' 7 7/8' 0I/4" J ORIliz„ LL TVP4 PATTERN FOR OHO PANEL CUTOUT DOOR REMOVED FRAME ODOR SHOWN OPEN DOOR IN FRAME OPEN FRAME SCREW 3/8' ��HORIZONTAL CENTER LINE OF OH DOOR PANEL 0 EXTERIOR INTERIOR B OH DOOR PANEL Ba ]'VENT FRAME PROTRUDES INSIDE OH DOOR Ra NUT FLANGE INSTALLED DOOR SWINGING (DRIVEWAY) SIDE SECTION VIEW I. For each Vent cut a CLEAN, SQUARE, LEVEL 16' wide by 7-7/8' high hole conpletely though the button Over Head (OH) Door Panel with the botton of the hole level and no nore then 12' above finished grade (driveway). Looks best to center Vent verticoIIy of door pone). 2. For each Vent drill four ( 4 ) 1/4 inch dioneter holes conpleteIy through door pone) where shown. Vent frame nay be used as a tenpIate. 3. Clean oll sharp netal edges and burrs fron opening. Brush away any loose styrofoon iron the opening. 4. Renove Vent door fron Vent franc. (turn upside down, rotate batten of door outward and slide out of franc slots) 5. Insert Vent franc into OH Door Panel with SERIAL NUMBER LABEL on the BOTTLH. Check olignnent of holes in Vent franc with holes drilled in, OH door panel. Correct holes in OH Door panel if nessesary. Make sure Franc sits LEVEL and front flange is FLUSH with the front of Door Panel. CouIk nay be applied behind Vent front franc flange to seal Vent franc to face of OH Door Panel, 5. Place Nut lange on inside of Vent franc with nuts facing away fron OH Door, Insert 4 screws provided through front of Vent franc and through Door into Nut Flange. Tighten screws to secure frone to OH Door but do not over tighten, deforning OH Door or Vent Frone, 7. Check that franc is square and level. Check that slots are clear of debris, netal shavings, styrofoon and caulk. B. Install Yent door bock into Frone by grasping botton of Vent door (with plastic pins) and sliding the netaI pins on each side of the Vent door intaslots an the insides of franc. Let the Vent door slide down the path of the slots until they ore at the batten in the dinples. 9. Let the button of the Vent door go so that it rotates down into the Vent franc. Check that Vent door is latched on both sides. 10. Vent door should not open when (H door opens. Vent door only opens when in contact with flood water and OH Door is fully closed. SMART VENT Go with the flow I" 688-628-4115 www.snartvent .con ■OORSHOWN I -I f7i 1.1 f�1 INSTALLED AND CLOSED ' ' ' ' OPTIONAL SIDE FASTENING: 33"ROUGH OPENING' CLM1PiBRILL FROM BACK r•1 HEADER MAY BE REQUIRED DEPENDING ON WALL CONSTRUCTION r•1 WITH #33 BRILL (A 131 FOR SIDE STRAPS GO i l CONSULT LOCAL BUILDING CODES FOR STRUCTURAL REQUIREMENTS •• fla SELF TAPPING SCREW UPPER FRAME - tEHINDWALL f"I I"I I"I I"I UPPER FRAME ( LzcUt ( OltiN OlEN :I :. DOOR INSTALLED SWUNG INWARD INSTALL 4) 11a X112 LG SELF TAPPING SCREWS 3° O`CLEAT DQQR 1C-3/1' DETAIL -C• ROUGH _ cps T _, OPENING LOWER FRAME EXTERIOR LOWER FRAME MAX 1^1 I^' '^I 1^1 DOOR SHOWN BEING I I I I ' I I I DOOR SHOWN INSTALLED INSERTED INTO FRAME 4:1 1: :1 i.:1 AND OPEN r•1 r•I Ivry I..I°� I"1 :-EXTERIOR MEW" I I STRAPS GO BEHIND WALL MIS 1^I I^1 1^I 1^I CAN BE BROKEN OFF AT SLOTS 1-1 I.nI i-I To AVOID OBSTRUCTIONS 12 PLS 1. Prepare CLEAN 33" wide by 1 G-318" high hole for each set of four quad vents (2 blocks+ wide x 2 blocks high) with the bottom of the hole no more then 3.112" above finished grade. 2. Measure wall thickness and everbend (more than 9111•)12 straps at nearest slot to the measurementfrom pointed end. 3. Remove doors from frames. (tam upside down, rotate bottom of door outward and slide But of slots) 4. Assemble two sets of two frames together using two nylon spacers snapped into holes in rear of frames as shown in Betail "B". Place toplframe (one with short bottom flange) over and in front of bottom frame (one with short top flange) and Fasten front of frames together with two self topping screws as shown in Details "A° and OCO. be not over tighten screws. 5. Insert 2 straps into top slots of each TOP frame. Straps should have bent legs pointing up. After pushing teeth through rear slots, ONLY PUSH STRAPS ONE CLICK INTO FRONT SLOTS, they will be tightened later in installation. a. Caulk maybe applied to back of flanges for a better seal to wall face. Place frame assembly Into will opening by sliding the top str�ps behind wall and resting frame bottom an bottom of wall opening. Press flanges fight to wall face. 7. Reach though opening in bottom frames and install four bent straps into two bottom slots with the bent legs of the straps hanging sown behind wall and trapping wall between front flange and bent strap. Squeeze tight to back of wall. B. Install a strap on each side of frame assembly. Install with bent leg pointing outward behind the W211 and into slots on each of upper sides. Squeeze fight to wall. Now, squeeze top frame straps fightte wall. g. Make sure frames are flush to wall face, secure, square, level and all slots are dear of debris, mortar and caulk 141. Hold doors from the bottom, parallel to Bound with back facing Bound and re -install Into frames by Inserting top first and letting metal pins find slats. Push all way back and allow door to drop and rotate down. Both sides should be latched dosed. 34IT MAX FINAL GRAVE • 324 /2" X 1 0/8" ROUGH OPENING MODEL AVAILABLE AS SPECIAL ORDER Smart VENTO QUAD INSTRUCTIONS MODELS 1541-558 and 1549-561 Sim AUTOMATIC COVEN P Of EOOPMENI AS BY'SUANIVENL' IN NOTES: APPLY F INSTALL INSTALL INSURE INSURE MODEL ISO-110 SlwJ,SS SIR FIRE RATED SOLUTION - FLOOD VENT WITH ARE RATED DAMPER INSTALLATION INSTRUCTIONS 1. bl L' ELEVATION Of SBDYN on TYPE 'E' FIRE -RATED FLOW THRU VENT 'TTPE E' PRUIOE go MN nmE INIE OALI to SECURE Itul SNOYN TOP AHD 80110M ELEVATION D9N0 318 I= SS ILAT HEAD SHEET METAL SCRM >o STAINLESS STEEL SLEEVE AS MANUEACIURED BY'SNARTVENI' SIEVE MODEL 1540-Ml p p �J SCALE: 3' = 1'-0' E RATED CAULK AROUND SLEEVE THEN SCREW DAMPER IN FOUR PLACES BOTH, TOP AND BOTTOM - USE 3/8" MAX. LONG SCREWS- LEEVE INTO 16 1/4 X 8 1/4 ROUGH OPENING ALL VOIDS WITH ARE RATED CAULK LOODVENT INTO OPPOSITE SIDE OF OPENING USING ADHESIVE .EEVE COVERS ANY INNER BLOCK OPENINGS Smart VENT® .OLD VENT DOES NOT COME IN CONTACT WITH ARE DAMPER .WHILE BEING ROTATED FULLY IN BOTH DIRECTIONS 888-828 4115 YOUR LOCAL BUILDING CODE FOR SPECIFIC ARE CODE REGULATIONS WWWAMAMENT.60M ATEOVWENT. 10.1SOB