HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 91L19DORNYTRUCTIONFLORIDA ENERGY EFFICIENCY CODE F Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. BY Street: V ��K� \A n _ C Permit Office: ST. LUCIE COUNTY St. Lucie City, State, Zip: FT. PIERCE , FL, Permit Number. County Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall.Types(1442.0 sqft,) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ent Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. NIA R= ft. 4. Number of Bedrooms 2 d. NIA R= ft= 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft= 6. Conditioned floor area above grade (ft') 1446 b. N/A R= ftz Conditioned floor area below grade 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.36 101.25 ft' SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft= a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor Types (1445.5 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.17 PASS Total Baseline Loads: 48.08 1 hereby certify that the plans and specifications covered by Review of the plans and THE 5T9jA this calculation are in compliance with the Florida Energy specifications covered by this OF Code. calculation indicates compliance with the Florida Energy Code. lluo. PREPAR B Before construction is completed DATE: this building will be inspected for r7 M y compliance with Section 553.908 ° ¢ I hereby certify that this building, as designed, is in compliance Florida Statutes. !,), with the Florida Energy Code. G'0 WE OWNER/AIP �� BUILDING OFFICIAL: DATE: -�� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/17/2018 4:06 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: —OwnerPlame'. --NYNNEBUILDING CROP _1446 Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE J Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 ' 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' ___ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' ____ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' — 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' — 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' — 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' 0 1 0 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY _ _ 6 ft _ _ _ 0 _ _ _42 ft' _-_ _- _ _ _ _ --0 - - 1- - - -0 -- 9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 - - - 0 1 0 ROOF _ / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 16.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InS®EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block- Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InfiEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block- Ext InfiEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InfiEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InfiEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext Insd1AUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext Ins3REAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext Ins3REAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 4/17/2018 4:06 PM EnergyGauge® USA- FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1—SE=>NW— insulated - - ENTRY - — - - None .39 3 1 6 8 20.6 ft- WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.36 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in 0.36 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in 0.36 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in 0.36 0.25 N 37.5 ft' 1 ft 0 in 1 ft 4 in 0.65 0.21 N 40.0 ft8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None. None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000366 1349.6 74.09 139.34 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 DUCTS — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool_ 1 Attic 6 250 ft' Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre,Thermostat: C[[ei]]ling Fans: HeatiNov ng Jan ]]Y [X] Feb r[[X]]' Mar Apr M:yrX� May Jrj un [ ] Jul [[ ]] [X] Aug ff ]] [X] Sep [ ] L 1 Oct r[X'] Nov Nov rDC'� Dec Dec Venting I 1 Jan L 1 [[ 11 Feb lxl [X) Mar [ ] Jun [ ]Jul [[ ]) Aug [[ ]) Sep lxl [X] [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 58 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling /soffit y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipina and wirina Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sod kler cover Hates and walls or cinolinag a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/17/2018 4:06 PM EnergyGauge® USA- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) - _DISPLAY -CARD--- -- --- -- --- ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. , FT. PIERCE, FL, 1..New .construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Windows" Description a. U-Factor: Sgi, U=0.36 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.21 c. U-Factor: N/A SHGC: d. U-Factor: WA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: New (From Plans) 9. Wall Types Single-family a. Concrete Block - Ext Insul, Exterior b. Frame - Wood, Adjacent 1 c. N/A 2 d. N/A 10. Ceiling Types Yes a. Under Attic (Vented) 1446 b. N/A Area c. N/A 101.25 ft' 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 40.00 ft' 12. Cooling systems ft' a. Central Unit ft' 3.832 ft. 0.239 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. N/A R= ft' c. N/A R= ft' 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home:\ ,Y" ��y �p-.� � City/FL Zip: QSce Insulation Area R=4.1 1250.00 ft' R=11.0 192.00 ft' R= ft' R= ft' Insulation Area R=30.0 1446.00 ft' R= ft R= ft' R ft' 6 250 kBtu/hr Efficiency 34.8 SEER:15.00 kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 40 gallons EF: 0.97 Pstat 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/17/2018 4:06 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 wrightsDW* Project Sumilhary Entire House QUICK CALCS, INC. Lutir LNL. FT..PIERCa FL 34MB:Phone- Tn46"799 Fax 772-4A For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT..PIERCE, FL Notes: .�\4 Weather. Winter Design Conditions Outside db 42 � OF .Inside db. - 70 OF Design TD 28 OF Fort Pierce, FL; US Heating Summary Structure 17648 Btuh Ducts 5654 Btuh' Central vent (0 cfm)0 Btuh (none) . Humidification 0 .Btuh Piping 0 Btuh Equipment load _ 23503 Btuh. Infiltration Method Simplified FC,lonstructtiion quality Averagee Area t-) HPa�6 Coojing .- Volume (ftj 12511 12511 Airchanges/hour 0.45 - 0.23 Equiv. AVF (cfm) 94 48 Heating. Equipment Summary Make Cartier Trade CARRIERAIR CONDITIONING Model 25HBC536A`030 AHRI ref 7914585 8.5 HSPF 34600'_Btuh @ 470F 27 ,F 1180 cfm 0.049 cfm/Btuh 0.50 in H2O point = 32 OF Backup: Input = 7 kW; Output = 23069 Btuh, 100 AFUE Job: Date: By: Summer Design Conditions Outside db Inside.db - 90 75 OF OF Design TD 15 OF Daily range' ' L Relative humidity Moisture difference 50 61 % gr/lb Sensible Cooling EquipmentL:oad Sizing Structure 17520 Btuh Ducts 8536' Btuh Central bent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data Ratejswingg multipplier n 0.95 Equipment send le load 24753 Btuh Latent Cooling Equipmen4 Load Sizing Structure 3203 Btuh Ducts . Central vent (0 cfm) 2318. 0 Btuh Stuh. (none). Equipment' latent load 5521 Stuh to meet Equipment total load 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling EquipmentSummary ' Make Cartier Trade CARRIER AIR CONDITIONING Cond 25HBC536A`030 Coil' FX4DN(B,F)037 AHRI`ief 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360. Btuh Latent cooling 10440, Btuh Total cooling 34800' Btuh Actual.airfl0 1160 cfm. Airflow factor 0.045 cfm/Btuh 'Static pressure 650' in H2O Load sensible heat ratio 0.83 Manual J 8th Ed. wrightsoft 2017-Apr-11 09:29:38 R1gMSuke4D Unlrersal 201717.0.14 R$U03101 page 1 ...Wok CsloslDaownentslTliE GRAND CARLTON4446.rup Cate = MJ8 Front Door faces: N - + wrightsof - Right;J@ Worksheet Job: Entire House BIT .QUICK CALCS, INC. .3f.7 ST.. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fez 772466.6796 Email: QUICKCALC$@gOLCOM - - Y -Room name - - - - -- - - - - - o Emire House - - - EDR BEDROOM - - - - - �2 Fused v,A 3 RoomtleN t56.2 ft 8.7 R d 8.0 $ haWcool (5 4 Room dmensions Room ales 1445.6 W t.0 x 297.0 ft' - 297.0 ft Ty Construction 11-Wue 'or HiM Area (ttj Load Area (ft-) Load i - number (6tuh/fti F) (eWW" or perimeter (ft) Pull) or perimeter- (ft) (atuh) . i Heat I Coal Gross WP/S Heat Cool Gross WPIS Heat cool '6 13A-0ccs ;:...: -A143 n %:a 00 -2;55 503 -065 -. .,,1862 -:1184 '72;c 72 .,: ?38 ':<183 ir4A5-2mrr,:.' '<.0770,.rt '21,56, 19:31' .:38<' 0-..'815- 'Y,730.. ..0-'...- I• �1��1--G 13A-0acs 0.143 a 4.00 256 128 83 333 212 ..0=`. 0 0 .0 0 ,.•:''-ti 0 1Actam 1.270 a 35.56 97.29 24 2 848 2082 0 0 0 0 1, �--D ' 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W -: :JaZoes 0.143"-se .4.00 .-265 .-, .34 : 34 - .. 136 . 06 - ...0 , ., 0..:. .0:. 0. y/ 1Aclorn 0143 s 4,00 265 360 353 1414 899 216- 216 865 '550 I-C 1Ac1om 1270 .0143 s w 35.56 4.00 34.77 255 7 310 7 237 2,47 949 241 : 603 0 104 0 0 0 -.lAC-0sclm .. ..1.27o w - 3556 5521 32 2 - h40 1770 32' 72 2-: 288 1140 183 1770 -`VC-Csn- - .0770 w -�2156 .19;31 41 . 41 ..- 880 `788 :-.: 0 0 0 ?0 P 12w D 091 2.55 1.28 192 192 489 246 a 0 - 0 0 C, .t g16A30md::.'. '0.032 •:<090 .. �2:32 1446-'. 1448 .-- `,: 1295 ..'.,_;3354 :297 ,`-. 29Z 266 F 22A-tPl 0.989 2769 0.00 1446 156 - 4325 0 297 _ -.: 49 0 „1357 x ( i 627 c)AED excursion 918 .I I Enve1 °pe lass/ n 9N 14961 13340 4204 4003 12 it a). Infiltrsuon . 2397 791 848 232 ' :b) Roomven07ation" 0 0.- .. 0 0. 13 Internal gains: Occupants @ 230 6 1380 3 690 Appllances/other - 2000 0 I� Subtotel(Mes 6 to 13) 17848 17520 5053 4925 II 'Less mdemal load 0 0 0 .0. .lI Less Transfer 0 0 0 0 ttI Redistnhu8pn 0 0 0 0 1q' .subtotal 17848 .176M 5053 4925 15; Duct loads 32% 49% ram 8536 32% 49% 1601 24M Tow main load 1 .I Air required(chn) I 116D 1601 3281, -77 yr"-_-- RlghtSuiteO Unhamal 201717.0.14 RSY08101: . .:.tkk CalmlDocranetsk7HE GRAND CARL70N-1446.rup Calc=MJ3 Fmnt Door faces: N 2017-Apr-11 09.29:38 Page 1 F iitrrigi isoh- RighW@ Worksheet' Job: L Entire House . QUICK CALLS, INC. Bret .317 SO LUCIE LN, FT. PIERCE, FL 34946 Phone: 772d66-mg Fax 772-468-6796 Email; OWICKCALCS@AOLCOM name—_ _ _ _ _ _ _ _ _ Wrl Oft HRCHFN ,3 4 19ht Room dimensions; SO ft heaticool 8.0 ft 0ft heallcool , I, 5 Raom aea 6.0 x 54.0 fp 9.0 ft 1720 ft' 1.0 x 172.0 ft TY ConstructiontA- Wtre Or HTM AM (fM Load .A rea Load number (BtuWftm (BtuWft2) or perimeter (ft) (6tuh) or perimeter: (ft) (13tuh) Heat Coo Gross WPlS Heat Coo Gross WP/S Hea Cod jy 18y`f3A9ocsO143 0 y 4P5:2wn `0770 fl 2156 19;31 "➢' 0 0 :0 `0:' �• 11 iq 1= 11D0 1.270 a 35.56 8729 0 0 .0 0 0 0 0 1 0.390 a 10.92 11.31 0 0 0 0 0 0 0 1 i13A-0ccs 0;143 se......,a.00 .255 '. 0 o o . 0 o - 0.0 W 13A-4ocs 0.143 5 4.00 255 0 0 0 0 0 0 0 f L---G 1Actom 1270 s 3556 34.77 0 0 0 0 0 0 0 13A-0ocs- :... -0143 �w . ..4.00 256 0 `0 0 .0 U ` ..0. 0. '( I ,1Ac,1arl .1270 , w. . '35.66 .. M21 . 0 0 D - p .., p :4AS2om.. -.0.770 w"- 21,56 • 19M 0: 0 0 .0 0 0 �. .i; P 12C-0sw 0. 091 255 1.28 0 0 0 0 84 . .➢ 64 183 :18A30mtl'!:' <0 032 . i O.90 ''232 . `64 ::. ` _ 54 ": .. ,45 F _.22A-tol .ram;, .. ; ;.., 0989 - ...: 2769 0.00 54 ... 0 .. 0 .. 0 ... 172 0 0 c . _ :q . .. .. ..:. T. .....t I 1 ,I 6 c)AED exaasion -9 -170 I' 1,11 Envelope loss/gal n 48 117 . 317 311 1� a) Infi0ratton 0 0 0 0 .1i r 'b) Rocmpenf0a m o p' 0 0 1 Internal gains: 230 0 0 ➢ ,�anceslo@ther 0 2000 Subtotal Qines 6 to 13) 48 117 317 2311 . I� Less etlemal load 0 0 '0 0 Less bansfer 0 0 0 0 I' Redfstdbutlon 0 0 0 0 1¢I Subtotal Duct leads 32% 49% 48 15 117 57 32-/ aov 317 vin 2311 ssva i Calculations approved byACCA to meet all requirements of Manual J 8th Ed - �t, -* Virright ;Oiv. 2017-Apr-11 09:29:38 A ' RII;WS 0e® Unlwnsal 201717.0.14 RSU08101 page 2 ...dck CalcslDocumentsIM E GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N wrightsofr Right-J® Worksheet' °b Entire House Date: By: ,QUICK CALCS,INC. 317 ST. LUCIE UN., FT PIERCE, FL 34946 Phone: 772-16"799 Fax 77&46"796 Eoa1: OUICKCALCS@AOLCOM - - - —'T Room rlame BATH DR BEDROOM-2 i2 Bpossed wall 5.0 ft ft (3. Rgom height 8.'0 ft heatfcool 8.0 ft heaUcool [4 � ions 9.0 x 5.0 ft 1.0 x 203.5 ft Ls Room 45.0 ft2 ' 203.5 fe Ty Construction U-value Or HTA4 A rea Load AreaLOW number (Btuhffti°� (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter. (ft) (B) Heat Cooi Gross NIPIS Heat Cool Gross I wP/S Heat I Cod 6 a :13Cc4o0s 41d3 4 d 00 255 40 _ 40 : _'.160 ':,:. 102 128 %: 128 _• St3 32i I-.4A52am, lr♦! 13A-0acs 0:770 .n -2768 0 ,. 0 0^0 .0�.: 0 0.. ,. D.143 B 4.00 255 0 0 0. 0 80 56 225 141 �-G 1Actom 1.270 a 35.66 97M 0 0 0 0 24 2 848 20& 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 I IN .: <'.13A-0acs_ 0.143. se .4.00 - 255- 0 '0 0 . 0 :. 34 .34 .' 136' 8f V�1 13A4oca 0.143 s 4.00 255 0 0 0 0 32 32 128 . & I---f.' 1Aclom 1.270 s 35.66 34.77 0 0 0 0 0 0 0 g3A4oes a143 w- aoo 255 o• o o .o o a o 'I i� JActom 1270 w .35`56 55.27;0 ; 0 O, .:,0 0-. 0 O 4As2opl .. �0177.0 w ::2156 19.87, O ' 0- 0 .0 0:. 0 P „ 12C-0sw 0.091 255 1.28 , 0 0 0 0 0 0 0 [ ;0i032 - :' A6 232 4@:.-:. 45 90 . , 904 204 �::, 204 '- 182 ' •-4T i F ?2A•tpl - .. 0.989 :. - 27.69 ,.. 0;00 45 5 ..:.. 138 0 , 204 _ 34 946 C j. 1:1 Ernrlopeloss7gain 339 190 1 2978 3106 4 a) infiltration , 87 24 693 162 i b) Room ventilation 0 0 0 0 4 Internal gains: Occupants ® 230 0 0 1 .230 Appliances(other 'p p Subtotal Bines 6 tc 13) 425 214 .. 3571 . 3498 Less eetenal load 0 0 .0 .0 - Less transfer 0 - 0 0 0 Redistdbu8on 0 0 0 0 1 .Subtotai 425 214 3571 3498 1 Duct loads 32yo 49% 135 104 32% 49% 1131 1764 Total mom lead 560 318 4702 5203 'Air req-ed(cfm) 28 14 232 232 Calculations approved b ACCA to meet all requirementsW Manual J.8th Ed. . . ' wr'oh"Pft` 2017-Apr-11 09:29:38 Right-Sutte�el Universa1.201717.0.14 RSU08101' Page 3 ..:nick CaIcslDocomentslTHE GRAND CARLTON-1446.rup Cola = MJ8 Front Door faces: N - ► + Job: viiinlOtsofr RighWO Worksheet Entire House data: By. -QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Emil: QUICKCALCWOL.COM- _ _ _ _ 1 Room name LAUNDRY GRFAT/DNNG Med ag 8.0 ft 47.0 ft .13 Room height &0 ft heat/ccol 9.8 ft heat/cool 4 i5 Room dimensiorre 7.0 x 6.0 It 1.0 x 52&0 ft Room area 42.0 ft' 526.0 ft- Ty : Construction U-value Or HTlv1 Area Load Area. number pwftmF) (B wft) or perim termer (ft) (etuh) a perimeter (ft) (Btuh) Heat I Cool Gnxs N/P/S Heat Cool Gres WP/S Heat Cool v ^C4PS-20m 0143 -_11 400 256 '0'. ti - 0 �'0 255 }. 217 ->. -a69 ' 55E' - .. ... ;0770 n .;' �2t 56.. 19-91 `"0 �= 0 0 :0 .38.;' "0. 815 130 13A4= 0.143 a 400. 255 0 0 0 0 0 .0 0 0 1Aclom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 `D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W-r..,;13A-flocs 0143 se - .4.00 2-55 0 0 0 . 0 0 . 0: -0 0 W 13A-0aes a143 s 4.00 z55 48 48 192 122 0 0 0 0 �C 1Aclom 1270 s 3566 34.77 0 0 0 0 0 0 0 0 13A4ecs:' " .0143 w. 400 255 0 .0 0 0 206 165 661 420 7Aclorq -: . 1270 w 3550 ..5521 . .0 .0 0 0 0 0 ..: 0- 0 :0770 w :. 21511 " 119.31 ::0 :..: 0': 41 - 41 P 12C-0sw 0091 2.55 1:28 56 56 143 72 0:. 0 0 0 C...e r96A30md':::. r: °0032 ;090. :232 ":42'.-- 42 •_�.. '.r 38 '. .-. ".97 _526 >,;._ 526 ._,r 471 ,-.;1220 F 22A-td 0 989 27 69 0.00 42 6 166 0 526 47 1302 0 C)AED e=slon _22 668 Envelope lass/gain 539 .. 270 4897 4379 1� a): Infiltration 104 28 997 273 L. b) RoomvwdflaUm 0 0 0 0 r 13 Intemal gains: Occupants @ 230 0 0 2 .460 Appfiances/other 0 0 Subtotal Qines 6 to 13) 643 298 5994 . 5112 Less e#emal loatl 0 0 - 0 0 Less transfer 0 : 0 II Redistribution 0 0 0 0 14 S lfttol � 15 Duct loads 32% 49% 1145 32% 49PA 1899 2490 !! Tatal room loa4 846 443 7892 7802 Air mqulmd(cfm) 42 20 390 338 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - i� wrlghtsofY2017-Apr-11 09:29:380810t _ RlghtSuite® Universal 20171Z0.14 RSUPage 4 ...uick CaIcs1DocumemsX7HE GRAND CARLTON-1448.mp Cale = MJ8 Front Door faces: N wrightsoft Right.4.8 Worksheet Ehfirt H6US& QUICK CAMS, INC. 317 ST. LUCIE I.M. F1 PIERCE FL34946 Phone: 77246M799 Fax T72-4665796 E=1:QUICKCALCWOLCOM Job: Date: By, Ti -Ramnanre 2 B FOYER M. BATH. :3 corn hVgM' 7.0 ft S.0 ft Room dimertsions 8.0 ft heatfcool 8.0 ft heat/cod4 151 ROOM area 1 —value 1.0 x 50.0 ft 50.0 ft- 7.0 x 8.0 ft 56.0 ft'. Ty Coristruction Or HTM AmLoad Area (ft) Load nuryber (Btuhifo or perm((elar (ft) (Muh) or pemeter (ft) (Btuh) Heat Cod Gross N/pjS Heat I Cool am,, WpIS Heat. Cool A 16 -001 4:l AQq e r 32 0, M� 13A-1cm 0.143 a 4.00 255 48 27 108 .0 69 0 0 0 0 1.270 a 35.56 87.29 a 0 0 0 0 0 0 0 1100 0.39.0 0 11192 11.31 21 21 229 238 0 0 0 0 i W. -13A•A. . .. 0,143 se AOO '255 0 .0 0 0 0 �a i t -4ccs 13Arn 0.143 a 4.00 255 0 0 0 0 64 57 228 145 -G W IA�Ic 1 ZRI a 'w 35ZB 4.00 34.77 255 0 0 0 0 0 7 7 247 - 241 .0.143 1:270 w MW 65,21 0 0 0 0 0 0 .0 0 0 0 0 :0 0 0 0 Q.7M -W,� 21 86, jq.��j -C C 0 :0 P 12C-Osw 'SA - 0.091 255 1:28 72 72 183 92 0 0 0 0 A W . mU' dox .00 .45 116 '66 -"56 -�ifo 130 F- 22A-tpl 0989 27.69 0.00 60 7 194 0 56 8 222 0 T. w c)AED emursion -39 -38 ll ErmehWe losslon 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room venfilathan 01. 0 0 13 Internal gains: Occupants @ 230 Q 0 0 Appliancestother a 01 Subtotal (lines 6 to 13) 913 6m 885 56 Less axtental load 0 6 -Lechstransfer a 0 1251 0 Redistribution 0 0 0 14 Subtotal 913 w r '16 115 i - Duct loads 49-Al 2891 25B 32% -Fp- wrightsoft- . .. Right-Sulte@ Universal 201717.0.14 RSU08 101 ...tack CalcalDocurronts17HE GRAND CARLMN-1448.1up Calc = MJB Front Door faces: N 2017-Apr-11 09:29:38 . Page 5 - wrightsoft Duct System Summary. Endre'House QUICK CALCS, INC. ----3jrST.-LUCIEwF7.YIERmTc34ms Phone:.772<868799.. Faz 172-0668796 EmatI: DUICKCALCSna AOLCOM Far. THE GRAND WYNNE DES ztemal static pressure ff��ssuur dosses liaiiablestatic pressure Npply /_ return available pressure ,west friction rate L-tual airflow . ta( effectibe length (TEL) MENT, FT. PIERCE, FL Job: bate: By: Heating. Cooling 0.50 in H2O 0.50. in H2O 0 in H2O . 0 in H2O 0.60 :in H2O 0.60 irf H2O 0.250 / 0.250 in H2O 0.250 / 0.250in H2O 0.285 in/100ft - 0.285 irV100ft 1160 cfm 1160 oft 176 ft Name Design (Btuh) Htg (cfm) Gig (cfm) Design . FIR Diam Qn) H x W (in) Duct Mati . Actual Ln (ft) Ftg.Egv Ln (ft.) Trunk Bit h 560 28 14 0.364 4.0 OxO VIFx 22.4. 115.0 stl 0,EDROOM 2 h 4702 232 232 0.360 7.0 -OxO VIFx 23.9 1150: SH BEDROOM -A h 3327 164- 163 0.300 6.0 OxO VIFx 31.6 135.0 st2 BEDROOMS h 3327 164 163 0.285 6.0 OxO VIFx 46.6 135.0 st2 :OVER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 9REATA)IN1NG h 3946 195 169 0.300 7.0 OX0 VIFx 31.8. 135,0 st2 ORE VDIMNG-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 w?c c 3437 21 153 0.379 6.0 OxO VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361° 4.0' Ox0 VIFx 23.3 115.0 stl M•ennin h 768 58 34 0 0 Ox0 VIFx 0 0 `c ^'I 1 a 174 3 8 0.309 4.0 OXO VIFX 27.0. 135.0 S12 ■ Trunk Htg Clg . Design Veloc Diam H x W Duct !Name Type (cfm) (cfm) FIR (fpm) (In) (n) Material Trunk st2 PeakAVF 721 672 '0.285 918 12.0 0 x 0 VinIFlX st1 tb PeakAVF 1043 1091 0285: 1020. 14.0 0 x 0 VinlFix A .+VtfrlghtSoft' RIghtSuite®UnFMI]201717.0.14RSU0810i. ...Lick CelesiDoe mentsME GRAND CARLTON4446.mp Calc = MJ8 Fmnt Dobr faces: N 2017-Apr-11 09:29:38 Page 1 Grille Size ize (in)' Htg (cfm) Cli I TEL Design Velo6 Diam. H x W Stud/Joist Duct I I-Truhk- (Cfm) (ft) FR (fprh), (n) (1h) Opening-(n)_ Matl-� I ibl I GXO MO 1 11601 01 ol ol ol ox o �j -YqFx