Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FILE CQ PV FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION - Florida Department -of Business -and Professional -Regulation - Residential Performance Method C Project Name: ZAMUDIO AND ROSENDIZ RESIDENCE Builder Name: Street: ARNOLD AND 38TH STREET Permit Office: ST LUCIE COUNTY �t QY��® City, State, Zip: FORT PIERCE, FL, 34981 Permit Number: 41cie Owner: GONZALI ZAMUDIO AND AURORA ROSENDIZ Jurisdiction: ST LUCIE COUNTY co �n Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2) `k 1. New construction or existing New (From Plans) 9. Wall Types (1866.7 sqft.) Insulation Area 2. Single family or multiple family Multi -family a. Concrete Block - Ext Insul, Exterior R=4.0 1866.70 ft' b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2398.0 sgfL) Insulation Area a. Under Attic (Vented) R=20.0 2398.00 ft' 6. Conditioned floor area above grade (ft2) 2400 b. NIA R= ft2 Conditioned Floor area below grade (ft2) 0 c. N/A R= ft' 11. Ducts R it' 7. Windows(243.0 sgft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 100 a. U-Factor: Sgl, U=0.65 243.00 ft2 b. Sup: Attic, Rat: Attic, AH: Attic 6 100 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 23.6 SEER:16.00 c. U-Factor: N/A ft' b. Central Unit 23.8 SEER:16.00 SHGC: 13. Heating systems kBtu/hr Efficiency ' d. U-Factor: NIA ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 6.973 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (2400.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2400.00 ft2 b. Conservation features EF: 0.980 b. NIA R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.101 Total Proposed Modified Loads: 75.42 PASS Total Baseline Loads: 75.59 1 hereby certify that the plans and specifications covered by Review of the plans and S1 - this calculation are in compliance with the Florida Energy specifications covered by this OFKiiH v Code. calculation indicates compliance yea„ "' ; , with the Florida Energy Code. 11" O� PREPARED By: Before construction is completed DATE: - this building will be inspected for ° compliance with Section 553.908 • a I hereby certify that this building, as designed, is in compli nce Florida Statutes. !) 6t with the Florida Energy Cc COP. , OWNERIAGENT• 'r BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). JAN S J':9 8:O�P��' Lucie County, Permitting 1/1012019I -SrgyGauge® USA Section R405.4.1 Compliant Software Page 1 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: ZAMUDIO AND ROSENDIZ R Bedrooms: 5 Address -Type'_ --Street Address - — — BuildingType: User Conditioned Area: 2400 Lot# Owner Name: GONZALI ZAMUDIO AND AU Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: ARNOLD AND 38TH ST Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Multi -family FL, 34981 New/Ebsting: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Healing Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU A 1198 1114144 2 AHU B 1202 11178.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 LIVING ROOM A 286 2659.8 No 0 1 Yes Yes Yes 2 KITCHEN A 121 1125.3 Yes 0 1 Yes Yes Yes 3 DEN A 121 1125 No 0 1 Yes Yes Yes 4 FOYER A 110 1023 No 0 1 Yes Yes Yes 5 WIC 2A 30 279 No 0 1 No Yes Yes 6 BEDROOM 2A 196 1822.8 No 0 1 1 Yes Yes Yes 7 BATH 2A 54 502.2 No 0 1 No Yes Yes 8 BATH 1A 54 502.2 No 0 1 No Yes Yes 9 BEDROOM 1A 182 1692.6 No 0 1 1 Yes Yes Yes 10 CLST 1A 14 130.2 No 0 1 No Yes Yes 11 HALL 30 279 No 0 1 No Yes Yes 12 LIVING ROOM B 286 2659.8 No 0 1 Yes Yes Yes 13 KITCHEN B 123 1143.9 Yes 0 1 Yes Yes Yes 14 BEDROOM 2B 123 1143.9 No 0 1 1 Yes Yes Yes 15 FOYER B 110 1023 No 0 1 Yes Yes Yes 16 MASTER BEDROO 196 1822.8 No 0 1 1 Yes Yes Yes 17 M W IC B 30 279 No 0 1 No Yes Yes 18 M BATH B 54 502.2 No 0 1 No Yes Yes 19 BATH 2B 54 502.2 No 0 1 No Yes Yes 20 BEDROOM 3 B 182 1692.6 No 0 1 1 Yes Yes Yes 21 CLST 3B 14 130.2 No 0 1 No Yes Yes 1/10/2019 8:09 PM EnergyGauge® USA Section R405A.1 Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 22 HALL B 30 279 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpel 1 Slab -On -Grade Edge Insulation LIVING ROOM A 34 It 0 286 ft- _- 1 0 0 2 Slab -On -Grade Edge Insulation KITCHEN A l i ft 0 121 112 ___ 1 0 0 3 Slab -On -Grade Edge Insulation DEN A 22 ft 0 121 ft- __ 1 0 0 4 Slab -On -Grade Edge Insulation FOYER A 5 ft 0 110 ft. __ 1 0 0 5SIab-On-Grade Edge Insulation WIC 2A 1 ft 0 30 fl' _- 1 0 0 6SIab-On Grade Edge Insulation BEDROOM 2A 14 ft 0 196 ft- 1 0 0 7SIab-OrrGrade Edge Insulation BATH 2A 1 it 0 54 ft- ___ 1 0 0 8 Slab -On -Grade Edge Insulation BATH 1A t it 0 54 ft' ___ 1 0 0 9 Slab -On -Grade Edge Insulation BEDROOM 1A 14 ft 0 182 ft- 1 0 0 10SIab-On-Grade Edge Insulation CLST 1A 1 It 0 14 ft- __ 1 0 0 11SIab-On-Grade Edge Insulation HALL A 1 It 0 30 ft- ___ 1 0 0 12SIab-On-Grade Edge Insulation LIVING ROOM B 34 ft 0 286 ft' _ 1 0 0 13SIab-On-Grade Edge Insulation KITCHEN B lift 0 123 ft' 1 0 0 14SIab-On-Grade Edge Insulation BEDROOM 2B 22 It 0 123 ft' ___ 1 0 0 1SSlab-On-Grade Edge Insulation FOYER B 5 ft 0 110 ft' __ 1 0 0 16SIab-On-Grade Edge Insulation MASTER SEDRO 14 ft 0 196 fF 1 0 0 17SIab-On-Grade Edge Insulation M W IC B 1 ft 0 30 ft' _- 1 0 0 18SIab-On-Grade Edge Insulation M BATH B 1 ft 0 54 ft' _- 1 0 0 19SIab-On-Grade Edge Insulation BATH 2B 1 it 0 54 ft- _ 1 0 0 20SIab-On-Grade Edge Insulation BEDROOM 3 B 14 ft 0 182 ft' ___ 1 0 0 21SIab-On-Grade Edge Insulation CLST 3B 1 it 0 14 ft- -- 1 0 0 22SIab-On-Grade Edge Insulation HALL B 1 it 0 30 ft' 1 0 0 ROOF _ / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2600 ft' 0 ft' Medium 0.15 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2400 ft' N N FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) LIVING ROOM A 20 Blown 286 ft2 0.1 Wood _ 2 Under Attic (Vented) KITCHEN A 20 Blown 121 ft2 0.1 Wood 3 Under Attic (Vented) DENA 20 Blown 121 ft2 0.1 Wood _ 4 Under Attic (Vented) FOYER A 20 Blown 110 ft2 0.1 Wood _ 5 Under Attic (Vented) WIC 2A 20 Blown 30 ft2 0.1 Wood _ 6 Under Attic (Vented) BEDROOM 2A 20 Blown 196 ft2 0.1 Wood 7 Under Attic (Vented) BATH 2A 20 Blown 54 ft2 0.1 Wood 8 Under Attic (Vented) BATH IA 20 Blown 54 ft2 0.1 Wood _ 9 Under Attic (Vented) BEDROOM IA 20 Blown 182 112 0.1 Wood _ 10 Under Attic (Vented) CLST IA 20 Blown 14 ft2 0.1 Wood 11 Under Attic (Vented) HALL 20 Blown 30 ft2 0.1 Wood _ 12 Under Attic (Vented) LIVING ROOM B 20 Blown 286 ft2 0.1 Wood _ 13 Under Attic (Vented) KITCHEN 20 Blown 123 ft2 0.1 Wood _ 14 Under Attic (Vented) BEDROOM 2B 20 Blown 121 ft2 0.1 Wood _ 15 Under Attic (Vented) FOYER B 20 Blown 110 ft2 0.1 Wood _ 16 Under Attic (Vented) MASTER BEDRO 20 Blown 196 ft2 0.1 Wood _ 17 Under Attic (Vented) MWICB 20 Blown 30 ft2 0.1 Wood 18 Under Attic (Vented) M BATH B 20 Blown 54 ft2 0.1 Wood _ 19 Under Attic (Vented) BATH 2B 20 Blown 54 ft2 0.1 Wood _ 20 Under Attic (Vented) BEDROOM 3 B 20 Blown 182 ft2 0.1 Wood _ 21 Under Attic (Vented) CLST 3B 20 Blown 14 ft2 0.1 Wood 22 Under Attic (Vented) HALL B 20 Blown 30 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block - Ext InsdlIVING ROO 4 16 0 9 4 149.3 ft2 0 0 0.15 0 _ 2 W Exterior Concrete Block - Ext InsillIVING ROO 4 18 0 9 4 168.0 ft2 0 0 0.15 0 _ 3 W Exterior Concrete Block - Ext InsuKITCHEN A 4 11 0 9 4 102.7 ft2 0 0 0.15 0 _ 4 S Exterior Concrete Block - Ext Insul DEN A 4 11 0 9 4 102.7 ft2 0 0 0.15 0 _ 5 W Exterior Concrete Block - Ext Insul DEN A 4 11 0 9 4 102.7 ft2 0 0 0.15 0 6 S Exterior Concrete Block - Ext Insul FOYER A 4 5 0 9 4 46.7 ft2 0 0 0.15 0 _ 7 S Exterior Concrete Block -Ext InStSEDROOM2 4 14 0 9 4 130.7 ft2 0 0 0.15 0 8 N Exterior Concrete Block- Ext Insi9EDROOM 1 4 14 0 9 4 130.7 112 0 0 0.15 0 _ 9 N Exterior Concrete Block- Ext InstUIVING ROO 4 16 0 9 4 149.3 ft2 0 0 0.15 0 _ 10 E Exterior Concrete Block - Ext InsLEIVING ROO 4 18 0 9 4 168.0 ft2 0 0 0.15 0 _ 11 E Exterior Concrete Block- Ext InsJOTCHEN B 4 11 0 9 4 102.7 ft2 0 0 0.15 0 _ 12 E Exterior Concrete Block - Ext InstREDROOM 2 4 11 0 9 4 102.7 ft2 0 0 0.15 0 _ 13 S Exterior Concrete Block- Ext Insd9EDROOM 2 4 11 0 9 4 102.7 112 0 0 0.15 0 14 S Exterior Concrete Block - Ext Insul FOYER B 4 5 0 9 4 46.7 ft2 0 0 0.15 0 _ 15 S Exterior Concrete Block - Ext InsdNASTER BE 4 14 0 9 4 130.7 ft2 0 0 0.15 0 16 N Exterior Concrete Block - Ext Ins®EDROOM 3 4 14 0 9 4 130.7 ft2 0 0 0.15 0 1/10/2019 8:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft -in -Ft- - In - - - _ 1 N Insulated LIVING ROO None .39 3 6 8 20 ft- 2 S Insulated FOYER None .39 3 6 8 20 1? 3 N Insulated LIVING ROO None .39 3 6 8 20 ft' 4 E Insulated KITCHEN None .39 2 8 6 8 17.8ft- 5 S Insulated FOYER B None .39 3 6 8 20 fl' WINDOWS - - - Orientation shown is the entered, Pro osed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft- 8 It 0 In 1 It 4 in None None 2 W 2 Metal Low-E Single Yes 0.65 0.25 N 30.0 IF 1 It 6 in 1 It 4 in None None 3 W 3 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft- 1 It 6 in 1 It 4 in None None _ 4 S 4 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft- 10 It 0 in 1 It 4 in None None _ 5 S 7 Metal Low-E Single Yes 0.65 0.25 N 20.0 W 10 ft 0 in 1 it 4 in None None _ 6 N 8 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft' 8 It 0 in 1 It 4 in None None _ 7 E 10 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft- 1 It 6 in 1 It 4 in None None 8 E 10 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft- 8 It 0 in 1 It 4 in None None 9 E 11 Metal Low-E Single Yes 0.65 0.25 N 9.0 ft' 1 It 6 in 1 It 4 in None None _ 10 S 13 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft- 10 ft 0 In 1 It 4 in None None _ 11 S 15 Metal Low-E Single Yes 0.65 0.25 N 20.0 ft- 10 ft 0 In 1 It 4 in None None 12 N 16 Metal Low-E Single Yes 0.65 0.25 N 30.0 W 8 ft 0 in 1 fl4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 2604 142.95 268.85 .3136 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Ship Heat( None COPA 17 kBlu/hr 1 sys#1 2 Electric Strip Heat( None COPA 17 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 23.6 kBtu/hr 708 cfm 0.8 1 sys#1 2 Central Unit/ Split SEER: 16 23.8 kBlu/hr 714 cfm 0.8 2 sys#2 1/10/2019 8:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Exterior 0.98 50 gal 62.3 gal 120 deg None 2 Electric None Exterior 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # Company Name System Model # Collector Model # Area Volume FEF None None -- - - ft' DUCTS _ / —Supply— Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 100 ft' Attic 12 ft- Default Leakage Attic (Default) c(Default) c 1 1 2 Attic 6 100 ft- Attic 12 ft- Default Leakage Attic (Default) c(Default) c 2 2 TEMPERATURES ProgramablejrXT']hermostat N Fans: CMar Cooling Venting FebrX,� H jJan Mar Aprrjeiling 00 Jun t ] Jul [ j Aug [X� ] Sep rr Dee Decec [ ]Jan Feb Apr [ May Jun I 1 Jul EX] 1 Aug E 1 Sep l�l Oct Nov [ Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Ccoling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 1/10/2019 8:09 PM EnergyGauge® USA Section R405A.1 Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Defauft(B lbs/sq.ft. 0 ft2 0—ft---0.3 LIVING ROOM A Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN A Default(81bs/sq.ft. ft2 it 0.3 DEN A Defaull(81bs/sq.ft. ft2 ft 0.3 FOYER A Default(B lbs/sq.ft. ft2 ft 0.3 WIC 2A Default(B lbs/sq.ft. ft2 ft 0.3 BEDROOM 2A Default(81bs/sq.ft. ft2 ft 0.3 BATH 2A Default(81bs/sq.ft. ft2 ft 0.3 BATH 1A Default(B lbslsq.ft ft2 ft 0.3 BEDROOM 1A Default(8 lbslsq.ft. ft2 ft 0.3 CLST 1A Default(81bs/sq.ft. ft2 ft 0.3 HALL A Default(81bs/sq.ft. ft2 It 0.3 LIVING ROOM B Default(B Ibs/sq.ft. ft2 It 0.3 KITCHEN B Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 213 Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER B Default(81bs/sq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 M W IC B Default(81bs/sq.ft ft2 ft 0.3 M BATH B Default(81bs/sq.ft. ft2 It 0.3 BATH 2B Default(B Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 B Default(B lbs/sq.ft. ft2 It 0.3 CLST 3B Default(8 Ibs/s.ft. ft2 ft 0.3 HALL B Name: Signature: _QM222aL Rating Compant: Date: I—t—� 1/10/2019 8:09 PM EnergyGaugeO USA Section R405A.1 Compliant Software Page 7 of 7 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT_ CRITERIA Project Name: ZAMUDIO AND ROSENDIZ RESIDENCE Builder Name: Street: ARNOLD AND 38TH STREET Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34981 Permit Number: U Owner: GONZALI ZAMUDIO AND AURORA ROSENDIZ Jurisdiction: ST LUCIE COUNTY = Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped soffit PP ceilin 9/ insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop dawn stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls hosed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light futures Installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and Wring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exteriorwalls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover o fates gid walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 111012019 8:09 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE-LEVEL-(EPL)-DISPLAY- CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Multi -family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 5 13. Cooling system: Capacity 47.4 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2400 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 243.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 4.0 14. Heating system: Capacity 34.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 10151. 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 20.0 b) Cross ventilation No 11 b, c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed ased on installed code compliant features. Builder Signature: _ Date: a Address of New Home: ARNOLD AND 38TH STREET City/FL Zip: FORT PIERCE, FL 34981 1/1012019 8:09:44 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 + wrightsofto Pro 'ect Summary AH�A QUICK CALCS, INC. 317 ST LUCIE-LANE, FORTPIERCE,-FC34946Phone:772z46Gb799 FBS 772-066.679fi Email: Q KCALCWCp L.COM Project For. ZAMUDIOAND ROSENDIZ RESIDENCE ARNOLD AND 38TH STREET, FORT PIERCE, FL 34981 Notes: Job: Date: Jan 10, 2019 By: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 12734 Btuh Structure 13195 Btuh Ducts 2919 Btuh Ducts 4233 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none e) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 15654 Btuh Use manufacturer's data n Rate/swing multiplier Equipment 0.95 Btuh Infiltration sensible load 16556 Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3043 Btuh Ducts 1125 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft') 1200 1200 Equipment latent load 4168 Btuh Volume (f 3) 11160 11160 Airchanges/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 20724 Btuh Equiv. AVF (cfm) 60 30 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S241A AHRI ref Coil ASPT291314A AHRI ref 201786066 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 4.2 kW Sensible cooling 16520 Btuh Heating output 14298 Btuh Latent cooling 7080 Btuh Temperature rise 17 OF Total cooling 23600 Btuh Actual airflow 787 cfm Actual airflow 787 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlgft soft- 2019Jan-1018:39:19 ACCN •`•'-' "-'-MU^`^^ Right -Suite® Universal 2018 18.0.31 RSu081o1 Page 1 ...ghtso8 WACIZADIO AND ROSENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: S -+ wrightsoft® Project Summary7 Job: • Date: Jan 10, 2019 AHU QUICK ALCS, INC. PT LE C/O PY By: 317 ST LUCIE LANE, FORT PIERCE. FL 34946 Phone: 772466.6799 Fa[ 772466-6796 Emil: QUICKCALCS AOL.COM Project Information For. ZAMUDIOAND ROSENDIZ RESIDENCE ARNOLD AND 38TH STREET, FORT PIERCE, FL 34981 Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 12853 Btuh Structure 13570 Btuh Ducts 2919 Btuh Ducts 4233 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 15773 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 16913 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2743 Btuh Ducts 1125 Btuh Central vent (0 cfm) 0 Btuh Heatingy Coolingg (none) Area (ft2) 1200 1200 Equipment latent load 3868 Btuh Volume (ft') 11159 11159 Airchanges/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 20780 Btuh Equiv. AVF (cfm) 60 30 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S241A AHRI ref Coil ASPT291314A AHRI ref 201786066 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 4.2 kW Sensible cooling 16520 Btuh Heating output 14437 Btuh Latent cooling 7080 Btuh Temperature rise 17 OF Total cooling 23600 Btuh Actual airflow 787 cfm Actual airflow 787 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressu���� 20 Static pressure 1.00 in H2O Space thermo at p Load sensible heat ratio 0.82 J AN ST. Lucte C pn Perm ` etJla�lari�sa CCA to meet all requirements of Manual J 8th Ed. wrY9M1tsof[• 2019Jan-10 18:39;19 Right -Suite@ Universal 2016 18.0.31 RSU08101 Page 2 ...ghtsoft WAC\ZAMUDIO AND ROSENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: S wrightsoft° Right-M Worksheet Job: AHU A Date: Jan 10, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 77246"799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Fiyosed wall Room height Room dimensions Room area AHUA 100.0 ft 9.3 It 1200.0 ft' LIVING ROOM 34.0 ft 9.3 ft heat/cool 16.0 x 18.0 ft 28&0 ft' Ty Construction number U-value (Btuh/ftx°F) Or HTM (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Bluh) Heal I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 - 13AAocs 2 glazing, clr low-e 2 glazing, clr lower 11D0- - 13AAocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr lower 11DO 13A-0acs----- 2 glazing, clr lave 11D0_--_ 13AAocs 2 glazing, clr low-e 2 glazing, clr low-e 12A-tpb =�__r 22A-tph 0143 0650 0.650 �,_0.390 0. 0.650650 0.690 0.650 '- 0.390 -0.143 0.650 0.390 0.143 0.650 0.650 _0.K48 n n n _n_ a a a a a -a- s -s_ w w w _ - 4.00 18.20 18.20 �_10.92 0.00 0.00 0.00 0.00 0.00 --4.00 18.20 10.92 4.00 18.20 18.20 .23. 38.02 219 14.99 14.99 10.34.-_-20 0.00 0.00 0.00 0.00 0.00 �-2-19 14.99 _10.34 2.19 33.77 33.77 `2.20 0.00 279 30 20 0 0 0 0 0 279 40 ___20 372 9 15 _7200 1200 209 0 0 ___20 0 0 0 0 0 - 219 40 _20 348 0 0 1200 _ 100 835 546 364 �223 0 0 0 0 __ 0 876 728 ___ 219 1393 164 273 _3802 ` 3802 456 450 300 211 0 0 0 0 _ 0 - 479 600 _.___208 761 304 507 _2640 _ 0 - __ -149 0 20 _,..-_.a...20 0 0 0 0 __ 0 --0 0 0 - - 108 0 0 _20 0 0 0 0 0 0 0 0 --- 434 0 364 '287 0 300 �._211 0 0 0 0 0 '-0 0 -_y-0 333 0 507 ..m_. _ -�634 0 �-D W .____223 0 0 0 0 0, ��--0 0 1�----GGG D vp� 1-C u--D y/ IL--GG 167 0 15 '._288 -�288 152 0 0 �.,._234 �34 _0 610 0 273 -293 ,T 1293 F �1.358 6 c)AED exi:ursion 139 122 Emelope loss/gain 10903 7054 3552 2343 12 a) Infiltration b) Room ventilation 1831 0 491 0 623 0 167 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 5650 0 0 1500 Subtotal(lines 6to 13) 12734 13195 4174 4010 14 15 Less eldemal load Less transfer Redistribution Subtotal Duct loads 23% 32% 0 0 0 12734 2919 0 0 0 13195 4233 23% 32% 0 0 86 4261 977 0 0 69 4079 1309 Total room load Air required (cfm) 1 15654 787 17427 787 5237 263 5388 243 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 'fi'r' wr19ti,?tso4it- 2019Jan-1018:39:19 1�A RightSuOe® Universal 2018.0.31 RSU08101 Page 1 ...ghtsoft HVWZAMUDIO AND ROSENDIZ RESIDENCE.rup Cale =MJ8 Front Door faces: S wrightsoft' Right-J@ Worksheet AHUA QUICK CALCS, INC. 317 ST LUCI"VE, FORT PIERCE�,-FL 34946 Phone: 772A66-6799 Fas 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Jan 10, 2019 By: 1 2 3 4 5 Room name Exposed wall Room height Roam dimensions Room area 10rCHE4A 11.0 ft 9.3 ft heaticod 11.0 x 11.0 ft 121.0 ft2 DEN 22.0 ft 9.3 ft heaticool 11.0 x 11.0 ft 121.0 ft2 Ty Construction number 1-1-value (Btuh/ft�'F) Or HTM (Btuwft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) a perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cod Gross I N/P/S Heat Cold 6 11 - =gym ..- - 13A-0ocs 2 glazing, dr lowe 2 glazing, dr Ibwe -11D0 13A-0ocs 2 glazing, clr lave 2 glazing, dr low-e 2 glazing, clr lowe 11D0 13A-0ocs 2 glazing, clr lcwe 11DO 13A4ocs 2 glazing, clr low-e 2 glazing, clr lave _ - 16B-21ed--- 22A-tph -_ 0143 0.650 0.650 �0.390 0.143 0.650 0.650 0.650 =0.143 0.143 0.650 0.390 0.143 0.650 0.650 7_0,044 ,_1,35ll n n n Tn_ a a a a _e_ s s ,_s_ w w w = - 4:00 18.20 1&20 �10.92 0.00 0.00 0.00 0.00 __0.00 4 4.00 18.20 -219 14.99 14.99 _10.34 0.00 0.00 0.00 0.00 _-0.00 219 2.19:-_-0--0--0. 14.99 0 0 0. __O 0 0 0 0 0 - 0 0 - 0 0 0 -0 0 0 0 0 0 0 0 0 0 __0 0 0 0 0 __0 102 20 0 0 0 __0 0 0 0 0 0 82'330 20 0 0 0 0 '__0 0 0 0 0 _ 0 364 0 410 0 0 `149 -_837 0 0 0 _..-_0 0 0 0 0 _0 -180 300 _..r.0 224 0 0 � 266 0 __0 0 0 0 0 0 0 0 0 0 0 0. _0 0 0 0 0 0 ..._____0 0 0 0 0 4)! II--GG _10.92 4.00 18.20 18.2D -1 23 38.02 _10.34 2.19 33.77 33.77 =2,20 0.00 102 9 0 =21 121 __0 93 0 0 =t21 11 374 164 0 e_. 149 418 204 304 0 T268 _ 0 _-0 102 0 0 _^121 121 102 0 0 _121 �22 C__ � - F 6 c)AED excursion 105 -20 Envelope loss/gain 1105 880 2089 950 12 a) Infiltration b) Room ventilation 201 0 54 01 403 0 108 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 1200 0 0 500 Subtotal Qines 6to 13) 1306 2134 2492 1558 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 23% 32% 0 0 174 1480 339 0 0 123 2257 724 239/6 32% 0 0 174 2665 611 0 0 123 1681 539 Total room load Air required (cm) 1819 91 2980 135 3276 165 2221 100 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrlgM1esoa 2019Jan-1018:39:19 Right-Suite(D universal 201818.0.31 RSUD8101 Page 2 ...ghtsoft HVAC\ZAMUDIO AND ROSENDIZ RESIDENCE.rup Calc=MJB Front Doorlaees: S wrightsofC Right-J® Worksheet AHUA QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-0fi6-fi799 Fax 772-066-6796 Email: OUICKCALCS@AOL.COM Job: Date: Jan 10, 2019 By: 1 2 3 4 5 Room name Elposed wall Room height Room dimensions Room area FOYERA 5.0 fit 9.3 it heat/cool 5.0 x 22.0 it 110.0 fl2 WIC 2A 0 It 9.3 0 heat/cool 5.0 x 6.0 it 30.0 fP Ty Construction number U-value (BtuNft;°F) Or HTM (Btuhfft2) Area (fl2) or perimeter (R) Load (Btuh) Area (fP) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 11 13A-flocs ----- 2glazing, clr Iowa 2 glazing, clr Iowa 11DO 13A4ocs 2 glazing, clr Iowa 2 glazing, clr Iowa 2 glazier, Gr Iowa 11D0,__ i3A-0ocs -- 2 glazing, cIr Iowa 11DO -0.143 0.650 0.650 _,-,0.390 0. 0.650 0.650 0.650 0.390 -0.143' 0.650 --n n n -_n_ a a a a _- s s _s_ w w w - - -4.OD 18.20 18.20 _10.92 219 14.99 14.99 -10.34 -- 0 0 0 -- -- - 0 0 0 0 0 0 0 0 0 0 __0 0 0 0 0 0 58 0 - -0 0 0 _,_0 0 0 0 0 0 - --0 0 0 -0 0 0 0 0 0 0 __0 0 0 0 0 0 -,"-o 0 0 _-.Y.._.0 0 0 0 0 0 I--G ly 0.00 000 0..00 0.00 _0.00 4.00 18.20 _ 10.92 4.00 18.20 18.20 = 1.23 38.02. 0.00 0.00 0.00 0.00 _0.00 2.19 14.99 _ 10.34 2.19 33.77 33.77 _ ;2.20 _ 0.00 ____0 0 0 0 0 0 _--_0 0 0 0 0 0 26'"106 0 0 0 0 0 0 0 0 0 0 0 0 --0 0 III----GGGD V�1�G `D 47 0 0 0 0 -0 0 __0 0 0 0 =66 0 W I�-GG 13A-0ocs 2 glazing, clr Iowa 2 glazing, clr low-e _ - .. - 16&21ad 22A-tph _0.390 0.143 0.650 _0.650 ,._0.044 1.358 _20 0 0 0 _. 110 _ 110 -20 0 0 __ 0 ___110 5 _219 0 0 0 = 136 190 _208 0 0 0 __242 ---0 0 0 0 _=30 30 - _-0 0 0 0 0 0 0 =37 ---0 - ___ p., F =30 0 6 c)AED excursion -7 .1 Envelope loss/gain 651 501 37 65 12 a) Infiltration b) Room ventilation 92 10 25 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 oil 0 I 0 1 0 Subtotal Pines 6 to 13) 742 525 37 65 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 230/6 32°/k 0 0 -742 0 0 0 0 -525 0 0 23% 32% 0 0 104 141 32 0 0 83 149 48 Total room load Air required (cfm) 0 0 0 0 173 9 196 9 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. - - -# wri9ht�o6it- 2019-Jan-1018:39:19 RighSENDIZ Universal RESIDENCE. 16. Cal = MJ8 01 Page 3 ...ghtsoft HVAC1ZAMUDIO AND ROSENDIZ RESIDENCE.rup CaIc=MJB Front Door faces: S wrightsoft• Right-J@ Worksheet AHUA QUICK CALCS, INC. -- - -- 317STLUCIE-LANE7ORTPIERCFFL-34946P onh e: 772366B799 Fam-772466-6786-Emil: DOIC(CALCS@AOLCOM Job: Date: Jan 10, 2019 By: 1 2 3 4 5 Room name E)gvsad wall Room height Room dimensions Room area BEDROOM 2A 14.0 ft 9.3 ft heat/cool 14.0 x 14.0 it 196.0 ft2 BATH 2A 0 ft 9.3 ft heat/cool 9.0 x 6.0 It 54.0 ft2 Ty construction number U-value (Btuh/ftx°F) Or HTM (Btuh/ft2) Area (ft') or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NIPS Heat Cool Gross N/P/S Heat Cool 6 11 -�-_ IW46 s - - 2 glazing, Ur lam 2 glaring, Ur low-e 11p0 13AAocs 2 glazing, clr lowe 2 glazing, clr low-e 2 glazing, clr lowe 1100 r13A-0ocs 2glazirg; clr lowe 11D0_ _ 13A-4ccs 2 glazing, co- lc a 2glazing, clr lore ,MB-21bd 22A-tpli . ,_ ' -"`Oi143 0.650 0.650 _-_,__0.390 n n n _n_ a a a a e_ s - s -s_ w w �s.- 4.00 1&20 18.20 10.92 219 14.99 14.99 _10.34 -0 0 0 _0 0 0 0 _0 ... 0 0 0 _0 -0 0 0 _._0 0 0 0 0 ... 0 0 0 . 0 0 0 b -`--0 0 0 w0 0. 0.650650 0.650 0.390 0.390 0.143 0.650 0.00 0.00 0.00 0.00 ,_0.00 4.00 18.20 0.00 0.00 0.00 0.00 0.00 -`2.19 14.99 0 0 0 0 0 0 0 0 0 _0 :110 20 0 0 0 0 0 0 E 4-1 364 0 0 0 0 0 - -.- 0 300 0 0 0 0 0 0 0 0 0 0 _0 0 0 0 0 0 0 0 0 0 0 0 0 F-� 130 20 0 0 0 0 0 "'-'0 0 r� ___0.390 0.143 0.650 0.650 �10.92 4.00 1112D 1&20 '-`1.23 � 3&02, `10.34 219 33.77 33.77 0 0 0 =196 196 __-_ 0 0 0 0 0 0 =241 532 `_____0 0 0 0 431 0 --0-0 0 0 0 =54 0 0 0 _-0_0w 0 0 0 0 0 0 _ C-- F F =0:044 - 1.356 '^ ...__ __. 220 __POP =1.96 14 =54 0 67 0 119 0 54 __ m 6 c)AED excursion -31 5 Errelope loss/gain 1579 941 67 114 12 a) Infiltration b) Room ventilation 256 0 69 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 16D011 0 0 250 Subtotal pines 6 to 13) 1835 2509 67 364 14 15 Less eMemal load Less transfer Redistribution Subtotal Duct loads 23% 320/6 0 0 221 2057 471 0 0 167 2566 855 23% 32% 0 0 0 67 15 0 0 0 364 117 Total room load Air required (cfm) 2528 127 3521 159 82 4 481 22 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. 2019Jan-1018:39:19 RightSuiteO universal 201818.0.31 RSUD8101 Page 4 ...ghtsoft WACIZAMUDIO AND ROSENDIZ RESIDENCE.rup Cato = MA Front Door faces: S wrightsoft Right-J@ Worksheet AHUA QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772466-6796 Email: OUICKCALCS c1�OL.COM Job: Date: Jan 10, 2019 By: 1 2 3 4 5 Room name Eposed wall Room height Room dimensions Room area BATH to 0 it 9.3 It hee/cool 9.0 x 6.0 ft 54.0 ft2 BEDROOM 1A 14.0 ft 9.3 ft heat1c of 1.0 x 182.0 If 1820 ft2 Ty Construction number U-value (Btufdft-F) Or HTM (BtutJft2) Area (ft2) or perimeter (it) Load (Btuh) Area (ft2) or perimeter (it) Lead (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A4ocs _ 2 glazing, clr love 2 glazing, clr li w JiDO_ 1344acs 2 glazing, Gr Im-e0.650650 2 glazing, clr lower 291azing, clr lower 11D0_� 13A4acs 2 glazing, dr Im-e 11D0 13A4ocs 2 glazing, clr Iow4 2 glazing, dr Im-e 16&21ad,_ 22A-1ph ___ -O.T43 0.650 0.650 _0.390 0. 0.650 0.650 0.390 -0.143 0.650 n n n ,_.n- a a a a a s- s -s_ w w w ; A 4.00 18.20 18.20 10.92 0.00 0.00 0.00 0.00 0.00 -4.00 18.20 i219 14.99 14.99 -„,_,10.34 0.00 0.00 0.00 0.00 0.00 --2A9 14.99 0 0 0 __O 0 0 0 0 0 - 0 0 0 ___0 0 0 0 0 0 � V0 0 0 0 0 __.._.0 0 0 0 0 0 � �0 0 o 0 0 __0 0 0 0 0 r0 ^ 0 0 _,_-...__0 0 0 0 _719 -`-`13D 30 0 0 "`-100 0 0 _ -__-.0 0 0 0 0 0 0 401 546 0 „_O - 219 - 450 0 _O 0 0 0 0 __0 0 0 0 Vy 0 0 0 0 „-._0 0--0-0 0 0 0 0 0 0 0 GG Ill----GD II---GD 0 0 0 V+/ - L�rf' _0.390 0.143 0.650 0.650 _. �0.044 1.358 _10.92 4.00 18.20 18.20 e . ,�123 38.02 ,_10.34 2.19 33.77 33.77 __ _,2.20 0.00 _O 0 0 0 - 54 54 __O 0 0 0 w.0 0 0 0 � 7 0 0 0 =182 _ 182 -0 0 0 0 '_'-' 182 14 -0 0 0 0 "'_224 __,_, 0 0 0 400. F _ _;,'��;54 -0 0 0 _ _532 6 c)AED excursion 4 -20 Envelope loss/gain 67 115 1704 1049 12 a) Infiltration b) Room ventilation 0 0 0 0 256 0 69 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 200 0 0 Soo Subtotal Qines 6to 13) 67 315 1960 1618 14 15 Less e#emal load Less transfer Redistribution Subtotal Duct loads 23% 32% 0 0 19 85 20 0 0 33 348 112 23% 32% 0 0 19 1979 454 0 0 33 1651 630 Total mom load Air required(cfm) 105 5 459 21 2433 122 2181 98 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. - �rightsoR� 2019Jan-1018:39:19 RightSuile® Universal 2018 18.0.31 RSU08101 Page 5 ...ghtsoft HVA0ZAMUDIO AND ROSENDIZ RESIDENCE.mp Cale = MJ8 Front Door faces: S wrightsoft' Right-M Worksheet Job: AHU A Date: Jan 10, 2019 QUICK CALCS, INC. By. 317 STLUCIE LANE, FORT MERCE, FL 34946 Phone: 772-466-6799 Fax 77246&6796 Email: QUICKCALCS AOL.COM 1 2 3 4 5 Room name 5posed wall Room height Room dimensions Room area CLST to 0 It 9.3 It heat/cool 7.0 x 20 It 14.0 ft' HALLA 0 It 9.3 0 heat/cool 5.0 x 6.0 It 30.0 ft' Ty Construction number U-value (9tu IftMi') Or HTM (etuh/ft') Area (ft� or perimeter (ft) Load (atuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 11 V ey--G 13A; o ss --- - - 2glazing, clr low-e -2 glazing, clr lava 111)0--__ 13A4ocs 2 glazing, clr lava 2 glazing, clr lava 2 glazing, clr Iowa 1100 13A-0ocs --- 2 glazing, clr low-e 11D0-- 13A4ocs 2 glazing, clr lava _2 glazing, clr Iowa 168-21M -_ 22htPh --" "0343 0.650 0.650 0.390 0. 0.650 0.650 0.650 0.390 --0.143 0.650 0.390 0.143 0.650 0.650 _ p py1 1.358 - n n n ._n_ a a a a _e_ s a _a_ w w w ---_ ' ` 4.00 1&20 18.20 `10.92 0.00 0.00 0.00 0.00 _ 0.00 -4.00 18.20 _ 10.92 4.00 1&20 1&20 1.23 _3&02 -- - 2.19 14.99 14.99 ,_10.34 0.00 0.00 0.00 0.00 _ _0.00 '- 219 14.99 ._10.34 219 33.77 33.77 �220 �0.00 b 0 0 0 0 0 0 0 0 0 0 0 -_,__ 0 0 0 0 0 0 _. __. _.0 0 -__0 0 0 __ 0 _ 14 __ 0 0 0 0 ,.__a 0 0 0 0 0 --_0 0 __0 0 0 0 17 0 0 0 _ 0 0 0 0 0 0 ___.__0 0 -0-0-0 0 0 ___0 0 0 0 0 0 _-_0 0 0 0 __ 0 __30 30 0 0 a 0 0 0 0 0 __�...0 0 -._0 0 0 0 0 0 - 0 0 0 ___0 0 0 0 0 0 r_.�_0 0 _._.._0 0 0 0 i66 0 I--G 1--D _0 0 0 0 0 0 --_0 0 .0 0 0 0 _37, --0 `D 0 0 __0 0 0 0 V)/ II---GG _0.___-_0 0 0 0 _C__ F _ 14 14 _ 31 0 30 " 0 0 6 c)AEDexcursion --_--_-_ p -- � q Emelope loss/gain 17 301 37 65 12 a) infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 17 30 37 65 14 15 Less eldemal load Less transfer Redistribution Subtotal Duct loads 23% 32% 1 0 0 -17 0 0 0 0 JO 0 0 23% 32% 0 0 -37 0 0 0 0 -65 0 0 Total room load Alr required (cfm) 0 0 0 0 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed 2019Jan-1018:39:19 ACC RightSuite9 Universal2018 18.0.31 RSUD8101 Page 6 ...ghtsoR HVAMZAMUDlO AND ROSENDIZ RESIDENCE.mp Cale = MJ8 Front Door faces: S F�+wrightsot Right-M)Worksheet AHU 8 QUICK CALCS, INC. 317 STLUCIEI-ANE-,-FORTPERCE. Fl_ 34946 Phone: 772A68-8799 Fax 772d66-6796 Email: QUICKCALCS(aAOL.COM Job: Date: Jan 10, 2019 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area AHU B 100.0 ft 9.3 ft 1199.8 ft' WNG ROOM B 34.0 it 9.3 If heat/cool 1.0 x 286.0 ft 286.0 fF Ty Construction number U-value (Btuvft;*F) Or HTM (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) Area (ft') or perimeter (it) Load (Btuh) Heat Cool Gross WP/S Heat Cool Grass N/P/S Heat Cool 6 11 V 13A-0ocs-' 2 glazing, clr lcwe 2 glazing, or lbw- -11D0. 13A-0ocs 2 glazing, clr low-e 2 glazing, clr lowe 2 glazing, clr lowe 1100 r13A- 2 glazing, clr low-e 11D0 13A4ccs 2 glazing, Gr lowe . 2 glazing, or love 16&21ad=._,_ 22A-tph "-0143 0650 0650 `n. n n -n_ a a a a a '-s' s 400 1820 000 _.-1092 4.20 18.20 1820 1820 10.92 V 4.00 18.20 10.92 2.19 14.99 0.00 -10.34 2.19 33.77 33.77 33.77 10.34 -2. 19 2.19 14.99 278 30 0 229'917 0 0 546 0 219 164 1164 3Z7364 364 195 - 876 728 _219 0 0 0 �1476 � -515 0 0 _____219 530 0 364 364 0 0 0 0 ` - 282 0 0 ,w.208 290 0 507 675 0 "--0 0 T-501 450 0 . 208 679 504 675 675 185 479 600 149 0 0 20 160 0 15 20 0 --0 0 129 0 0 20 130 0 0 0 0 --0 0 ly - _0.39D 0.650 0.650 0650 0650 0.390 -0143 0.650 0390 -_,_20 379 9 15 20 18 __-____20 310 0 0 0 18 �D 279 40 219 40 ly L�CG _, 0.143 0.650 0.650 _s_ w w w -"" r 0.00 0.00 0.00 1,23 3&02 -10.34 0.00 0.00 0.00 ---220 0.00 _20 0 0 0 1198 1198 ___.20 0 0 0 '"`�1196 ��' too _-_208 0 0 0 2636 ""`3802 0 -0 0 0 0 `-286 286 ,_„_____0 0 0 0 �286 �34 0 0 0 -0 0 0 0 _ 829 0 ----_ - C� F _0 044 1 358 352 1293 6 c)AED excursion 0 33 Envelope loss/gain 11022 7429 3547 2623 12 a) Infiltration b) Room ventilation 1 1831 0 491 0 1 623 0 167 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 5650 0 0 1500 Subtotal (lines 6 to 13) 12853 13570 4170 4290 14 151 Less eMemal load Less transfer Redistribution Subtotal Duct loads 23% 31% 0 0 0 12B53 2919 0 0 0 13570 4233 23% 31% 0 0 86 4256 967 0 0 69 4359 1360 Toted room load Air required (ctm) 15773 787 17803 7871 1 5223 261 5719 253 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. ,oft-FI.f wriglr,tsoR- 2019-Jan-1018:39:19 RightSuiteO universal 2018 18.0.31 RSU08101 Page 7 ...ghtsoft WAC\ZAMUDIO AND ROSENDIZ RESIDENCE.rup Cale =MJS Front Door faces: S I# wrightsoft• Right-M Worksheet Job: AHU B Date: Jan 10, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 2 3 4 5 Room name Eposed wall Room height Room dimensions Room area KITCHEN B 11.0 ft 9.3 ft heat/cool 11.0 x 11.0 it 121.0 ft2 BEDROOM 2B 22.0 it 9.3 ft heat/cool 11.1 x 11.1 ft 122.8 ft2 Ty Construction number U-value (Btuh/W2F) Or HTM (Btuh/ft2) Area (ft') or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (it) Load (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S I Heat Cool 6 11 13A-flocs 2 glazing, cir low- 2 glazing, cIr low- 11D0-_ 13AAces 2 glazing, Ur low- 2 glazing, cIr low-e 2 glazing, cIr low- 11D0 13A- _-_ 2 glazing; cIr low- 11D0 - 13AAocs 2 glazing, clr low- 2 glazing, clr low- 168-21ad 22 ph_, 0.143 0.650 _ 0.650 n n n _n_ a a a a s s _s_ w w w - 4.00 18.20 0.00 1092 4.00 18.20 18.20 1820 1092 - 4.o0 18.20 ._10.92 0.00 0.00 0.00 38,02 219 14.99 0.00 _10.34 2.19 33.77 33.77 33.77 10.34 -2.19 14.99 ._10.34 0.00 0.00 0.00 -2.20_. _-0.00 0 0 0 __0 102 9 0 0 18 �- 0-0- 0 _,.,0 0 0 0 121 121 0 0 0 0 0 0 0 ___0 302 164 0 0 195 0- 0 __0 0 0 0 ^_149 v418 0 0 0 __0 165 304 0 0 185 0 0 ___0 0 0 0 _268 0 0 0 0 0 0 0 0 0 -- 0` 0 0 __0 410 0 0 0 0 "-330 364 0 0 0 0 149 -0 0 0 -0 224 0 0 0 0 160 300 v_0 0 0 0 _ 266 �G L-D �0.390 0.143 0.650 0.650 0650 0390= --0143 0.650 75 0 0 0 18 0 __0 0 0 0 _,_,121 11 102 0 0 0 0 102 20 _-..-.,_.0 0 0 0 =121 121 102 0 0 0 0 -...__ 82 20 _.._ _0 0 0 0 _121 22 U�l�G �D _0.390 0.143 0.650 _0.650 _0.044-'1:23 1.358 C= , F 6 c)AED excursion 1 -7 Emelope loss/gain 1228 921 2089 962 12 a) Infifiration b) Room ventilation 201 0 54 0 403 0 108 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 1200 0 0 500 Subtotal (lines 6 to 13) 1430 2176 2492 1570 14 15 Less exdemal load Less transfer Redistribution Subtotal Duct loads 23% 31% 0 0 174 1603 364 0 0 124 2299 717 23% 31% 0 0 174 2665 605 0 0 124 1694 529 Total room load Air required (cfm) 1968 98 3016 133 3271 163 2223 98 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -Pk- wrlgM1esof--[- 2019-Jan-1018:39:19 h A&k RightSuite® Universal 201818.0.31 RSU08101 Page 8 ...ghtsoft WAC\ZAMUDIO AND ROSENDIZ RESIDENCE.mp Calc=MJ8 Front Door faces: S wrightsoft• Right-JO Worksheet AHU B QUICK CALCS, INC. Job: Date: Jan 10, 2019 By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466.6799 Fac 772466-6796 Email: QUICKCALCSQAOL.CDM -- i 2 3 4 5 Room name E)q=ed wall Room height Room dimensions Room area FOYER B 5.0 ft 9.3 ft heat/cool 5.0 x 220 0 110.0 ft- MASTER BEDROOM B 14.0 If 9.3 ft heat/cool 14.0 x 14.0 ft 196.0 W Ty Construction number U-value (BtuWfti°F) Or HTM (Btuh/ft'j Area (0') or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cod Gross NIP/S Heat Cool 6 i t 73A-4ocs " 2 glazing, clr lowe 2 glazing, clr Im-e 11D0 _ 13A4ocs 2 glazing, dr lowe 2 glazing, or lowe 2 glazing, dr laws 1100 13A4ocs 2 glazing, dlr lowe JIDO--- 0.143 0.650 0.650 ,0.390 0.650 0.650 0.650 0.650 0.390 -0.143 0.650 n n n _n_ a a a a a sT s _s_ w w w - 4.60 18.20 0.00 _10.92 218 14.99 0.00 ,10.34 - -0 0 0 0 - - -O 0 0 0 -0 0 g _____-,0 0 0 0 0 0 ' 241 300 0 0 0 0 _____0 0 0 0 , _0 - 0 0 0 -0.---0 0 0 0 0 0 0 0 �G `D 18.20 8.20 18.20 18.20 10.92 4.00 18.20 _10.92 0.00 0.00 0.00 =�1:73 38.02 3.77 33.77 33.77 33.77 10.34 2.19 14.99 _10.34 0.00 0.00 0.00 =2.20 0.00 0 0 0 0 0 0 0 0 0 __ 0 26 0 __20 0 0 0 �110 5 0 0 0 0 0 106 0 __219 0 0 0 138 190 0 0 0 0 0 0 0 0 0 0 ' 130 20 0 0 0 0 �196 196 0 0 0 0 0 0 0 0 0 0 441 364 ---0 0 0 0 =2ri'I 532 `D. - 47 0 _20 0 0 0 _` _�110 110 58 0 208 0 0 __ 0 _242 0 110 20 --0 0 0 0 �196 14 ly __ C_ F 13A4acs 2 glazing, clr lave 2 glazing, clr lave _768-21ad 22A-toh _0.390 0.143 0.650 _0.650 _0.044 1.358 0 0 0 ---431 0 6 c)AEDexcursion S -12 Fmelope loss/gain 651 505 1579 960 12 a) Infiltration b) Room ventilation 92 0 25 0 256 0 69 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 1500 Subtotal (lines 6 to 13) 742 630 1835 2529 emal load nsfer0 bution l0 ads23% V 31% 0 -742 0 0 0 -530 0 0 23% 31% 0 0 221 2057 467 0 0 158 2687 838 omload lred(cfm) 0 0 0 0 2524 1261 3525 156 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -Fk- wrl9r+bo_Tt- 2019Jan-1018:39:19 A A RightSuite® Universal 2018 18.0.31 RSU08101 Page 9 ...ghtsoit WACIZAMUDIO AND ROSENDIZ RESIDENCE.mp Cale = MJ8 Front Door faces: S 9 it wrightsoft• Right-J@ Worksheet Job: AHU B Date: Jan 10, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-066fi7g6 Email: OUICKCALCS@AOL.CgM 1 2 3 4 5 Room lane F�posed wall Room height Room dimensions Room area M WIC B 0 it 913 ft heat/cool 5.0 x 6.0 it 30.0 W M BATH B 0 it 9.3 R heal/cool 9.0 x 6.0 ft 54.0 fP Ty Construction number U-value (BtUlVftz°F) Or HTM (Btuh/ft-) Area (ft') or perimeter (ft) Load (Bluh) Area (1111 or perimeter (ft) Load (Btuh) Heat Cool Gross N/P!S Heat Cool Gross N/P/S Heat cool fi 11 13A-0ocs 2 glazing, clr lave 2 glazing, Ur lower 1ID0 13A-0pcs 2 glazing, clr loa-e 2 glazing, clr lave 2 glazing, clr Iowa 11D0 a4llocs 2 glazing, clr Iowa _11D0 13A-4ocs 2 glazing, clr lc v e 2 glazing, clr Iowa .168-21ad 22A-tph ^ -0.143 0.650 0.650 0.30 '- n n n -n_ a a a a a s s _.s_ w w w 4.00 18.20 0.00 _10.92 .20 18.20 18.2D 18.20 10.92 i 4.00 18.20 --'-219 14.99 0.00 _10.34 . 333.7777 33.77 33.77 10.34 -'2.19 14.99 - - - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _0 0 0 0 0 0 0 0 0 0 � 0 0 0 0 "�"-0 0 0 - -0 0 0 0 0 0 --0V�/�(' 0 0 -_0 0 0 0 0 0 .. r �D Vj/ 0. 0.650650 0.650 0.650 0.390 -0.143 0.650 0 0 0 0 0 0 0 0 0 0 -0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -0 0 0 Illl----GGGD 4��G �D 0 0 -0 0 -0 0 0- 0 0 0 0 0 0 0 �0 0 -_0. 0 0 0 �719, 0 4y I�-GG 'C7 F _0.390 0.143 0.650 0.650 =0.044 1.358 _10.92 0.00 0.00 0.00 _ 1-23 38.02 -10.34 0.00 0.00 0.00 220 0 00 -0 0 0 0 =30 30 -0 0 0 0 _30 0 --0 0 0 0 �37 0 0 0 0 _66 0 0 0 0 54 __0 0 0 0 -0 0 0 0 167. 0. `54 0 �54 6 c)AED excursion 0 -2 Finelope loss/gain 37 66 67 117 12 a) Infiltration b) Room ventilation 0 1 0 0 01 0 0 0 0 13 Intemal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 250 Subtotal (lines 6 to 13) 37 66 67 367 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 239/6 31% 0 0 104 141 32 0 0 84 150 47 23% 31% 0 0 0 67 15 0 0 0 367 114 Total room load Air required (cfm) 113 9 196 9 82 4 482 21 Calculations approved byACCA to meet all requirements of Manual J Sth Ed. 2019Jan-1018:39:19 RlghtSuiteO Uniwmal2018 18.0.31 RSU08101 Page 10 ...ghtsoft WAC\ZAMUDIO AND ROSENDIZ RESIDENCE.mp Cate =MJ8 Front Door faces: S wrightsoft Right-M Worksheet Job: AHU B Date: Jan 10, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Fax T72466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Bowed wall Room height Room dimensions Room area BATH 213 0 ft 9.3 ft heaUcod 9.0 x 6.0 ft 54.0 ft- BEDROOM 3 B 14.0 It 9.3 ft heat/cool 1.0 x 182.0 ft 182.0 ft2 Ty Construction number U-value (Btuh/ftMF) Or HTM (Btuhtft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (it) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N7P7S Heat Cool 6 11 13A450 2 glazing, clr lave 2 glazing, clr lave ,11D0 _ 13A-0ocs 2 glazing, clr love 2 glazing, clr lcw a 2 glazing, dr low-e 1100 13A- 2 glazing, clr low2 J100- 13A4ws 2 glazing, clr Iow-e 2 glazing, cir Iow-e 16&_tph 27htph 4A0 18.20 0.00 _-_10.92 4.00 18.20 18.20 1820 _10.92 4.00 18.20 219 14.99 0.00 _10.34 2.19 33.77 33.77 33.77 10.34 -2.19 14.99 - 0 0 0 ,._,___,0 0 0 0 0 0 0 0 0 __ _.,_0 0 0 0 0 0 - 0 0 0 0 0 0 -0 0 0 -`130 30 0 ®._ ._.0 0 0 0 0 0 "`100 0 0 0 -401 546 0 0 - - - 219 450 0 -0. 0 0 0 0 0 - J0 0 -0 0 0 0 400. ,�,_0 -0.143 0.650 0.650 0.390 - n n n ^n_ a a a a e_ s s -s_ w w w u - 1y 0. 0.650 0.650 0.650 0.390 0.143 0.650 0.390 0 0 0 0 0 -0 0 0 0 0 0 v0 0 0 0 0 0 0 0 0 0 0 0 0 Ili-�_r--GGD 1--G �--D 0 0 0 0 -0-0-0 0 0 y/ _ I�CG C_ F 0.143 0.650 0.650 =1.358 _ 1.358 ._.10.92 0.00 0.00 0.00 -�123 33.02 ,._.10.34 0.00 0.00 0.00 '�v„ 230 0.00 _-_0 0 0 0 54 54 __.o 0 0 0 �_,54 0 -_0 0 0 0 _0 0 0 0- �119 :____0 0 0 0 „„ �182 _ 182 -0 0 0 0 �114 14 ___.0 0 0 0 �.__ _.___,224. �532 �67 0 0 6 c)AED e¢ursion -2 S Envelope loss/gain 67 117 1704 1062 12 a) Infiltration b) Room ventilation 0 0 0 01 256 0 69 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 200 0 0 500 Subtotal (lines 6 to 13) 67 317 1960 1630 14 15 Less e#emal load Less transfer Redistribution Subtotal Duct loads 23% 31% 0 0 19 85 19 0 0 33 350 109 239/6 31% 0 0 19 1979 450 0 0 34 1664 519 Total room load Air required (ofm) 105 ,55 460 20 2429 121 2183 97 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wM9titso_iP[- 2019dan-1018:39:19 .CA RightSude® Universal 2018 18.0.31 RSU08101 Page 11 ...ghtsoft WAC\ZAMUDIO AND ROSENDIZ RESIDENCE.rup Calc=MJ8 Front Door faces: S wrightsoft Right-M) Worksheet Job: AHU B Date: Jan 10, 2019 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fos 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Bposed wall Room height Room dimensions Room area CLST 3B 0 ft 9.3 N heat/cod 7.0 x 2.0 it 14.0 W HALL B 0 ft 9.3 It heat/cod 5.0 x 6.0 it 30.0 ft- Ty Construction number U-value (Btuh/WF) Or HTM (Btuh/f -) Area (it-) or perimeter (ft) Load (Btuh) Area (ftj or perimeter (ft) Load (Bluh) Heat I Coot Gross WP/S Heat Cool Gross WP/S I Heat I Cod 6 11 V jI--G 13A;4cs _ _ 2 glazing, air Iowa' 2 glazing, clr lave 11D0____ - 13A-0ocs 2 glazing, clr lave 2 glazing, clr lave 2 gluing, clr Iowa 1100_ 13A-0ocs - 2 glazing, dr low-e JIM___ 13A4o:s 2glazing, air lwx 2 glazing, clr Iowa _%B-21ad__,_ 22A-tDh__ _6._43'n 0,650 0.650 - 0.390 0. 0.650650 0.650 0.650 0.390 - -- 0.143 0.650 n n _n_. a a a a a s - s _s_ w w w - - 4.06___2.19 18.20 0.00 _70.92 4.00 18.20 18.20 18.20 10.92 4.00 18.20 14.99 0.00 ,10.34 2.19 33.77 33.77 33.77 10.34 2.19 14.99 10.34 ____0__ 0 0 _.,___0 0 0 0 0 0 ^-0 0 _ _0 0 0 __0 0 0 0 0 0 ---- 0 0 0 __ 0 0 0 _ __0 0 0 0 0 0 0 0 0 0 0 0 _ ___0 0 0 0 0 0 --0 0 0 __0 0 0 ___0 0 0 0 0 0 _-0 0 0 0 0 __._0 0 0 0 0 ___ 0 0 0 -0-0 0 0 _-__ 0 0 0 0 0 0 0 0 __0 0 0 0 0 0 I--G �--D �j I-=C �D 0 0 0 -'0 0 __0 0 0 0 -30 _ 0. 0, Vy II----GG -0.390 0.143 0.650 0.650 __0.044 __7.358 -10.92 0.00 0.00 0.00 = M 38.02 _ 0.00 0.00 0.00 = 220 _ 0._00 __0 0 0 0 == 14 __ 14 0 0 0 0 0 0 0 0 0 --V_31 � 0 __0 0 0 0 _,__0 0 0 0 = 0 0 0 0 `__97 0 C_ F 14 0 =--17 _� 0 - 30 __ 30 6 c)AED excursion 0 0 Envdope loss/gain 17 31 37 66 12 a) Induration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 17 31 37 66 14 15 Less exdemal load Less transfer Redistribution Subtotal Duct loads 23% 31% 0 0 -17 0 0 0 0 31 0 0 23% 31% 0 0 37 0 0 0 0 -66 0 0 Total room load Air required(cfm) 0 0 0 0 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-1018:39:19 Right -Suite® Universal 201818.0.31 RSU08101 Page 12 ...ghtsoft WACIZAMUDIO AND ROSENDIZ RESIDENCE.mp Cale =MJB Front Door faces: S 9 9 Duct System SummaryJob: WI'1 F1tSOft' � Date: Jan 10, 2019 AHU A By: - -- QUICK-CALCS,-INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: T72-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM Project Information For. ZAMUDIO AND ROSENDIZ RESIDENCE ARNOLD AND 38TH STREET, FORT PIERCE, FL 34981 Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 787 cfm 177 Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 787 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) CIg (cfm) Design FIR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH IA c 459 5 21 1.000 5.0 Ox0 VIFx 37.2 135.0 st3 BATH 2A c 481 4 22 1.000 5.0 Ox0 VIFx 42.0 135.0 SIM BEDROOM to h 2433 122 98 1.000 7.0 Ox0 VIFx 37.2 135.0 s13 BEDROOM 2A c 3521 127 159 1.000 8.0 Ox0 VIFx 23.3 115.0 stl DEN h 3276 165 100 1.000 7.0 Ox0 VIFx 26.5 115.0 st1 KITCHEN A C 2980 91 135 1.000 7.0 Ox 0 VIFx 25.5 115.0 st1 LIVING ROOM A h 2619 132 122 1.000 7.0 Ox 0 VIFx 42.2 135.0 st3 LIVING ROOM A -A h 2619 132 122 1.000 7.0 Ox 0 VIFx 35.5 135.0 st3 WIC 2A c 196 9 9 1.000 4.0 0x0 VIFx 21.3 115.0 st1 Supply Trunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st3 Peak AVF 395 384 1.000 724 10.0 0 x 0 VinlFlx st1 st1 Peak AVF 787 787 1.000 854 13.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (Cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Jotst Opening (in) Duct Mall Trunk rb2 Ox0 787 787 0 1 0 0 0 Ox 0 1 VIFx Wrightsoft' 2019Jan-1018:39:21 �p •�+•• a-.�+-, RighlSuite® Universal 2078 18.0.37 RSU08101 Page 1 ...ghtsoft HVACIZAMUDIO AND ROSENDIZ RESIDENCE.rup Calc = MJ8 Front Door faces: S 1- wrightsoft Duct System Summary AHU B _QUICK CALLS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM For. ZAMUDIO AND ROSENDIZ RESIDENCE ARNOLD AND 38TH STREET, FORT PIERCE, FL 34981 Job: Date: Jan 10, 2019 By: Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual airflow 787 cfm 787 cfm Total effective length (TEL) 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2B C 460 5 20 1.000 5.0 OxO VIFx 36.0 135.0 st4 BEDROOM 213 h 3271 163 98 1.000 7.0 Ox0 VIFx 27.4 115.0 st2 BEDROOM 3B h 2429 121 97 1.000 7.0 0x0 VIFx 36.5 135.0 st4 KITCHEN c 3016 98 133 1.000 7.0 Ox0 VIFx 25.6 115.0 st2 LIVING ROOM B h 2611 130 126 1.000 7.0 Ox 0 VIFx 33.7 135.0 st4 LIVING ROOM B-A h 2611 130 126 1.000 7.0 Ox 0 VIFx 40.9 135.0 st4 M BATH B C 482 4 21 1.000 5.0 Ox 0 VIFx 39.3 135.0 st4 M WIC B c 196 9 9 1.000 4.0 Ox 0 VIFx 20.6 115.0 st2 MASTER BEDROOM B C 3525 126 156 1.000 8.0 Ox0 VIFx 24.0 115.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st4 Peak AVF 391 391 1,000 717 10.0 0 x 0 VinlFlx st2 st2 Peak AVF 787 787 1.000 854 13.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mall Trunk rb1 Ox0 787 787 0 0 0 0 Ox 0 VIFx wrightsoft- 2019Jan-10 18:39:21 •�u•� �� RighlSufte® Unh,ersal 2018 18.0.31 RSU08101 Page 2 AI.t.N ...ghtsoft FIVAC1ZAMUDIO AND ROSENDIZ RESIDENCE.mp Celc = M.8 Front Door faces: S