HomeMy WebLinkAboutEVALUATION REPORTC R lrl �I � Certificate of Authorization No. 29824
1��I ILI 1 17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT
FLORIDA BUILDING CODE, 6Te EDITION (2017)
Manufacturer: TAMKO BUILDING PRODUCTS
Issued September 25,2017
220 West 40 Street
Joplin, MO 64801
(417)624-6644
Manufacturing Plants: Joplin, MO
SC
Phillipsburg, KS
By
Frederick, MD
t LUCie
Dallas, TX
COun
`y
Tuscaloosa, AL
Quality Assurance: UL LLC (QUA9625)
SCOPE
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
TAP-043-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-051-02-01
TAS 100
.1995
PRI Construction Materials Technologies (TST5878)
TAP-054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-114-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-131-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-165-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-280-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-303-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-307-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-314-02-01 Rev 2
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-315-02-01
ASTM D 6381
2008(2013)e1
PRI Construction Materials Technologies (TST5878)
TAP-317-02-01
TAS 100
1995
UL LLC (TST9628)
02NK9507
ASTM D 3161
2016
UL LLC (TST9628)
04NK24366
ASTM D 3462
2010A
UL LLC (TST9628)
05NK28006
ASTM D 6381
2008(2013)e1
UL 2390
ASTM D 7158
2011
UL LLC (TST9628)
06NK03898
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
08CA59132
ASTM D 3161
2016
UL LLC (TST9628)
09NK07896
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
10CA50498
ASTM D 3462
2010A
UL LLC (TST9628)
10CA64882
ASTM D 3161
2016
.UL LLC (TST9628)
11NK14014
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
12CA24551
ASTM D 3161
2016
UL LLC (TST9628)
4786110543
ASTM D 6381
2008(2013)e1
UL LLC (TST9628)
4787043752
ASTM D 3161
2016
UL LLC (TST9628)
4787148748
ASTM D 7158
2011
ASTM D 3161
2016
ASTM D 3462
2010A
CREEK Technical Services LLC (ANE11669)
TBP15001.3
Calculations
2017
TBP15001.4
FL18355-R4
Page 1 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
C R E E K TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite Glass -Seal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick, Joplin & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass -Seal
(Frederick &
Tuscaloosa)
Glass -Seal
(Joplin)
Heritage®
(Dallas, Frederick,
Joplin, Phillipsburg &
Tuscaloosa)
Heritage® Premium
(Dallas, Frederick,
Phillipsburg &
Tuscaloosa)
Heritage® Premium
(Frederick)
12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
ceramic granules complying with ASTM D 3462.
12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass
mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shingles shall be used in the non-HVHZ only.
13-1/4" x 39-3/8", ASTM D 3161,
reinforced, laminated architectural
complying with ASTM D 3462.
13-1/4" x 39-3/8", ASTM D 3161,
reinforced, laminated architectural
complying with ASTM D 3462.
Class F and ASTM D 7158, Class H fiberglass
asphalt shingle surfaced with mineral granules
Class F and ASTM D 7158, Class H fiberglass
asphalt shingle surfaced with mineral granules
12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage_® Vintage@ __ _ 17-1/2"-x-40TASTM-D3161—Class-F and-ASAvl-D-7158-Glass-1 fiberglass reinforced,
(Phillipsburg) laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Woodgate 13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas & Frederick) reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage® Woodgate 12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick) asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles 12-1/4" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick & Joplin) shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage® Hip and Ridge 12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg) surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4 FL18355-R4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
INSTALLATION
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Elite Glass -Seal®
Basic Wind Speed (V it):
Max. 194 mph
(Frederick, Joplin &
Basic Wind Speed (Vasa):
Max. 150 mph
Tuscaloosa)
Deck (HVHZ):
In accordance with FBC requirements;
&
Solidly sheathed min. 19/32 in. plywood or woad plank for
Glass -Seal
new construction; Min. 15/32 in. plywood existing
(Frederick, Joplin (Non-
construction.
HVHZ) & Tuscaloosa)
Deck (Non-HVHZ):
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
Underlayment:
In accordance with FBC requirements.
Min. slope:
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (HVHZ):
Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installation (Non-HVHZ):
Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
Nailing
Area
Butt Edge
Figure 1. Elite Glass -Seal & Glass -Seal
4 Nail Pattern (Non-HVHZ only)
Butt Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nail Pattern
-7ff
5-1/8"
718"
i-118"
TBP15001.4 FL18355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage®
Basic Wind Speed (V,,,):
(Dallas, Frederick, Joplin,
Basic Wind Speed Nud)
Phillipsburg & Tuscaloosa)
Deck (HVHZ):
Heritage® Premium
(Dallas, Frederick
Phillipsburg & Tuscaloosa)
Deck (Non-HVHZ):
Heritage® Woodgate
(Dallas & Frederick)
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ)
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph _
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattem" or "6 Nail Pattem" detailed below.
FASTENERS
NAIL ZONE
COMMON
BOND
EXPOi URE 6-6/8"
12-1 /2" -11�-1 12-3/8" f 12-1 /2'l' - �11-1 "
Figure 3. Heritage@, Heritage@ Premium, and Heritage® Woodgate (Dallas)
4 Nail Pattern (non-HVHZ only)
1" h-7-1/2'L+- T.
FASTENERS NAIL ZONE
COMMON
�� BOND
7-1
EXPOSURE 5-5/8"
Figure 4. Heritage@ & Heritage@ Premium
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
>7=
TAMKO BUILDING PRODUCTS
Asphalt Shingles
uAn ZONE/
MON BOND
1!L k-1/2+7-1/2'44.73/8„ 112+7-1/2U� �-1"
Figure 5. Heritage@ Woodgate
6 Nail Pattern
M Common Bond
1 39-W I
Figure 6. Heritage@, Heritage@ Premium, & Heritage@ Woodgate
Alternate 6 Nail Pattern
Figure 7. Heritage@ (Tuscaloosa)
Expanded Nail Zone
Nail pafterns from Figures 3, 4, and 6 may be placed in the nail zone as described above
TBP15001.4
FL18355-R4
5 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
1-1-91
CREEK
TECHNICAL SERVICES, LLC
Heritage@ Premium Basic Wind Speed (V it):
(Frederick) Basic Wind Speed (Vasa):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph.
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattem" or "6 Nail Pattern" detailed below.
NAIL ZONE/
COMMON BOND
1 "-►I N-- 11 "- +- 12" "- �--1"
Figure 8. Heritage@ Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
5112"
Figure 9.
511
NAIL ZONE/
- 9"-4-3° 91/2n 1*-1 n
Heritage@ Premium (Frederick)
6 Nail Pattern
BOND
TBP15001.4 _ FL18355-R4 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
Heritage® Woodgate Basic Wind Speed (V"u): Max. 194_mph
(Frederick) Basic Wind Speed (Vnd): Max. 150 mph
Deck (Non-HVHZ): In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
Undedayment: In accordance with FBC requirements.
Min. slope: 2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installation (Non-HVHZ): Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
NAIL ZONE/
FASTENERS COMMON BOND
5-1/2" EXPOSURE 5"
f
TLA �-- 11"--+-12-318"--+r 11" -►I [0-1"
Figure 10. Heritage® Woodgate (Frederick)
4 Nail Pattern (non-HVHZ only)
ZONFJ
VON BOND
T
5 1 FEXPOSURES"
Figure 11. Heritage® Woodgate (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4
7 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage® Vintage@ Basic Wind Speed (V,h):
(Phillipsburg)- Basic Wind Speed (Vwd):
Deck (HVHZ):
Deck (Non-HVHZ):
Undedayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with. RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturers published installation
instructions. Shingles shall be attached using either "5 Nail
Pattern" or "6 Nail Pattern" detailed below.
xpnS m
Dbxh
Figure 12. Heritage@ Vintage@
5 Nail Pattern (non-HVHZ only)
Figure 13. Heritage@ Vintage
6 Nail Pattern
TBP15001.4 - FL18355-R4 Page 8 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Hip & Ridge Basic Wind Speed (Vmd:
(Frederick & Joplin) Basic Wind Speed (Veld):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction prevailing wind
exposure
Figure 1
1�
1' 'Fastener
Figure 2
Figure 14. Hip & Ridge (Frederick & Joplin)
>xposure
TBP15001.4 FL18355-R4 Page 9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Vintage® Hip & Ridge Basic Wind Speed (V ii):
(Phillipsburg) Basic Wind Speed (Vasa):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7116 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
exposure
Figure 1
1"
Fastener
Figure 2
a-- exposure
rigures
Figure 15. Vintage® Hip & Ridge (Phillipsburg)
TBP15001.4 FL18355-R4 Page 10 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6 h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
�• No 74021
STATE OF 441
ii�Ct`Cc, O� OR 1 O p \�1��
�,'SSIONA� %
CERTIFICATION OF INDEPENDENCE
2017.09.25
11:31:41
p,—v,avn
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE11669
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.4 FL18355-R4 Page 11 of 11
This evaluation report is provided for State of Florida product approval under.Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
TRINITY I ERD
EVALUATION REPORT
TRI-BUILT Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800)516-1485
EXTERIOR RESEARCH & DESIGN, I.I.C.
-Certificate of Authorization#9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
(203)262-9245
Evaluation Report A42960.10.12-R6
SCANNED FL36048-R6
BY Date of Issuance:10/25/2012
St, Lucie County Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on o9/25/2017. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
QUNITY ERD
ROOFING COMPONENT. EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 6t6 Edition (2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2011
1SO4.3.1
Wind Uplift
UL 1897
2012
1504.6
Accelerated Weathering
ASTM G155
2005
1507.2.4 / 1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
Physical Properties
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties
S40540.11.13
11/19/2013
ERD (TST6049)
Physical Properties
S40540.03.14
03/26/2014
ERD (TST6049)
Physical Properties
544870.04.14-2
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-3
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-1
04/10/2014
ERD (TST6049)
Physical Properties
544870.04.14-4
04/10/2014
ERD (TST6049)
Physical Properties
S43530.02.14-1-RS
05/14/2014
ERD (TST6049)
Physical Properties
S43530.05.14
05/28/2014
ERD (TST6049)
Physical Properties
540540.10.14
10/31/2014
ERD (TST6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SC8520.04.15
05/27/2015
ERD (TST6049)
Wind Resistance
SC14045.05.17-RS
06/07/2017
UL, LLC. (QUA962S)
Quality Control
Multiple -Listing R16814
12/10/2015
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
Exp. 07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built
Sand-R SA Shingle Underlayment
is a self -adhering, glass -mat reinforced,
sand -surfaced, SBS
modified
bitumen roof underlayment, with a
36-inch sheet width; meets ASTM D1970.
4.2 Tri-Built
S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced,
SBS modified
bitumen
roof underlayment; meets ASTM D1970
and FRSA/TRI April 2012.
4.3 Tri-Built
Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced,
film -surfaced, SBS
modified
bitumen roof underlayment; meets
ASTM D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, I.I.C. Evaluation Report A42960.30.12-R6
Certificate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 2 of 6
�1 TRINITY ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
_ - TABLE 1: ROOF COVER OPTIONS -
Underlayment
Asphalt
Nail -On Tile
Foam -On Tile
Metal
Wood Shakes
Slate
Shingles
& Shingles
Tri-Built Sand-R SA Shingle
Underlayment
Yes
No
No
No
Yes
Yes
Tri-Built S/A HTTU
Yes
Underlayment
Yes
Yes
See 5.5.1
Yes
Yes
Yes
Tri-Built Smooth HT 5/A
Underlayment
Yes
No
No
Yes
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
_ TABLE IA: ALLOWABLE TILE ADHESIVE/ UNDERLAYMENT:COMBINATIONS _
Adhesive
Florida Product Approval
Underlayments
ICP Adhesives Polyset® AH-160
FL6332
Tri-Built S/A HTTU Underlayment
Dow TileBoncl"
FL22525
Tri-Built S/A HT TU Underlayment
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
OSB prior to installation of the self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D or TAS 114, Appendix 1.
' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, LLC. Evaluation Report A42960.30.12-R6
Certificate of Authorization#9503 6r"EDITION(2017)FBC NON-HVH2 EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 3 of 6
rTRINI-ry ERD
5.6.3 Bond to Mechanically Attached Base Laver:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 3A or
FBC 1609 for determination of design wind pressures.
#1 Maximum Design Pressure=-45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
#3 Maximum Design Pressure=-150.0 osf
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps.
#4 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet:
Underlayment:
Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Tri-Built S/A HT TU Underlayment, self -adhered.
Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6
Certificate of Authorization #9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 4 of 6
,�,I TRINITY I ERD
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
TABLE2: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECx TILE INSTALLATIONS -
Underlayment
Tile Profile
Staging Method
Maximum
Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Max. 10-tile stack (bottom 2-tile stack
shall be inverted, followed by 8 tiles high
6:12
on slope, as shown below)
Tri-Built S/A HTTU
Underlayment-s
Lugged
5.
Exterior Research and Design, LLC.
Certificate ofAuthorizotion A9503 6'"EDITION (2017)FBC NON-HVHZ EVALUATION
TRI-BUILT Roof Underlayments; (800) 516-1485
Evaluation Report A42960.10.12-R6
FL16048-R6
Revision 6: 09/25/2017
Page 5 of 6
�I ! KIMIY ERD
6. INSTALLATION: -
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlavment, Tri-Built S/A HT TU Underlavment or Tri-Built Smooth HT S/A
Underlavment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 30 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications (Tri-Built S/A HTTU Underlavment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report A42960.10.12-116
Certificate of Authorization U9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FLI6048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 6 of 6
L. Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville, NC 27023
434-688-0609
rllomas@Irlomaspe.com
Manufacturer: MI Windows and Doors, LLC
650 West Market St
Gratz, PA 17030
Product Line: 5764 - Horizontal Mullion
Engineering Evaluation Report
Report No.: 512072AB
SCANNED
SP, LucBy
ie Countu
Compliance: `y
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(d). The product
listed herein complies with requirements of the current Florida Building Code.
Supporting Technical Documentation:
1. Approval document: drawing number 08-01448 Revision B, prepared, signed and sealed by Luis Roberto
Lomas RE
2. Mullion analysis report No. 512072-1A and -2A per AAMA 450-10 Option 3, prepared, signed and sealed by
Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: refer to design pressure charts in approval document.
• Maximum single window unit size: 52 1/8" x 84"
• Window units attached to mullion must have their own separate approval.
• This product is not rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in Wind -Borne Debris Regions, up to
Wind Zone 3.
• Design pressure of mulled units shall be controlled by the lesser design pressure of the assembly
components; mullion or individual units.
• All windows attached to mullion must be manufactured by MI Windows and Doors, Inc.
Installation:
Mullion must be installed in strict accordance with manufacturer's instructions and approval document 08-01448
Revision B.
Certification of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other
entity involved in the approval process of the listed product(s).
1of1
NN
E At
*• 51 ••
•TAT OF +,�=
ORIOP #�����
ALI0�����
10/13/2017
H1
MAX.
1
COMBINED
HEIGHT
H2
WINDOW
WINDOW
52 1/8"
MAX. UNIT WIDTH
(MULLION SPAN)
Maximum design presssure
Tributary
height
(in)
Mullion span (In)
18.00 24.00 30.00 36.00 42.00 48A0 52.13
1100
120.0
120.0
120.0
120.0
120.0
120.0
119.1
24.00
120.0
120.0
120.0
120.0
120.0
107.0
95.0
30.00
120.0
120.0
120.0
120.0
114.1
93.4
79.9
3600
120.0
120.0
120.0
120.0
107.0
85.6
71.0
42.00
120.0
120.0
120.0
120.0
104.8
81.5
65.8
48.00
120.0
120.0
120.0
120.0
104.8
80.3
63.2
54.00
120.0
120.0
120.0
120.0
104.8
80.3
62.7
MOO
120.0
120.0
120.0
120.0
104.8
80.3
62.7
66.00
120.0
120.0
120.0
120.0
104.8
80.3
62.7
72.00
120.0
120.0
120.0
120.0
1D4.8
80.3
62.7
78.00
120.0
120.0
120.0
120.0
104.0
80.3
62.7
84.00
120.0
120.0
120.01
120.01
104.8
1 80.3
1 62.7
LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE
DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT
INCLUDEFLANGE
DESIGN PRESSURE TABLE INSTRUCTIONS:
1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE
CHAPTER 16.
2) DETERMINE TRIBUTARY HEIGHT AND MULLION SPAN BASED ON
PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY HEIGHT.
3) LOCATE MULLION SPAN (UNIT WIDTH) AND TRIBUTARY HEIGHT. AT
THE INTERSECTION OF COLUMN AND ROW CONTAINING THE MULLION
SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING
FOR PRODUCT IN STEP 2.
MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED
DESIGN PRESSURE OBTAINED IN STEP 1.
TRIBUTARY HEIGHT= H1 + H2
2
TABLE OF CONTENTS
:ET NO. DESCRIPTION
1, 2 ELEVATION, NOTES AND DESIGN PRESSURE CHARTS
3 INSTALLATION DETAILS
REVISIONS
OESCROMON pnlE MPnO
A I REVISED INSTALLATION DETAILS O6/10/15 R.L.
B REVSED INSTALLATION DETPILS 10/13/fJ R.L.
NOTES:
1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO
COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND
ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE.
FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE
ARCHITECT OR ENGINEER OF RECORD.
3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE
DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION
FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS
PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3
5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS
DOCUMENT APPLY ONLY TO THE MULLION. WINDOWS MUST BE
APPROVED UNDER SEPARATE APPROVAL.
6) SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN
IN THIS DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE
MANUFACTURED BY MI WINDOWS AND DOORS
7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE
LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL
WINDOW UNIT.
8) VERTICAL MULLIONS ARE NOT PART OF THIS APPROVAL. VERTICAL
MULLIONS USED TO MULL UNITS SIDE BY SIDE MUST HAVE
SEPARATE APPROVAL,
9) FOR ADDITIONAL APPROVED CONFIGURATIONS SEE SHEET 2.
SIGNED: 1011612017
MI WINDOWSD DOORS, LLC
650GT MARKET STREET ```N''l1n :ICI� \`RATZ, PA 17030 NS`
NS�I4d
5764 HORIZONTAL MULLION _ 0 v,6jX
A
SINGLE AND TWIN WITH TRANSOM 9E
ELEVATION AND GENERAL NOTES �qf• TAT OF
oB-a1aaB B %/js/pNALENO��
3/O6/12 sNEEri OF 3//I111111111���
LROBERTOLOMASP.E I Luis R. Lomas P.E.
1DMROROLEWISWU&NC27423 FL No.: 62514
NN.lI4 rlMmvtldlMmnam mm
Hl
68"
MAX.
COMBINED
HEIGHT
WINDOW
7HE7DOW
104.25"
MAX. UNIT WIDTH
(MULLION SPAN)
Maximum
deskan aressure capacity chart
Tributary
Height
Mullion Span (in(
(In(
600
72.00
U-OO
96-00
104.25
16.00
"A
27.5
18.3
24.00
33.8
21.0
30.00
27.7
17.1
3600
23.8
4200
21.0
46.00
110.5
71.3
19.0
54.00
17.4
60.00
64.2
30.2
16.2
6600
15.3
-
7200
87.8
58.3
27.3
-
76.00
83.5
55.4
26.0
-
-
84.00
79.6
52.8
24.9
LARGEAND SMALL MISSILE IMPACT, LEVEL O, WINOZONE3
DIMENSIONS IN CNARTARE FRAMEDIMENSIONSAND DO NOT
INCLUDE FLANGE
DESIGN PRESSURE TABLE INSTRUCTIONS:
1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16.
2) DETERMINE TRIBUTARY HEIGHT AND MULLION SPAN BASED ON PRODUCT TO BE
INSTALLED. SEE FORMULA FOR TRIBUTARY HEIGHT.
3) LOCATE MULLION SPAN (UNIT WIDTH) AND TRIBUTARY HEIGHT. AT THE
INTERSECTION OF COLUMN AND ROW CONTAINING THE MULLION SPAN AND
TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP
2.
MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN
PRESSURE OBTAINED IN STEP 1.
3 3/4" -
1' AIL^ 3/81312
[t2
27/3
T---
2 X 07/32"
1 27 2"
SECT5796 CLIP 2X 07/32"
FOR CONCRETE INSTALLATION
ALUMINUM 6063-1`5.12 -TRICK
3/4"
-7�� 3/8"
SECT5796 CLIP
FOR CONCRETE INSTALLATION
ALUMINUM 6063-IS. 125'THICK
TRIBUTARY HEIGHT = H1 + H2
2
2 1/322 7/8"
8••
REY1510X5
RESCRIPTON MM gpPRp
RINSED INSTALLATION DETAILS 05/10/15 R.L.
REVISED INSTALLATION DETAILS 10/13/17 R.L.
3/32"
i
SECT5764 MULLION
ALUMINUM 6005-T5.125-THICK
3 3/4"
2 3/16"
3/8"
27/32"
1 9/161�9/116�"1n� 2X 07/32"
/1� 1 9I
SECT5796 CLIP
FOR WOOD FRAMING INSTALLATION
ALUMINUM 6063-75.125" THICK
650 WEST MARKET STREET
GRATZ, PA 17030
5764 HORIZONTAL MULLION
SINGLE AND TWIN WITH TRANSOM
ELEVATION AND COMPONENTS
V.L. 1
08-01448
' NTS Imm 03/06/12 XX-2 OF 3
L ROBERTO LOMh6P.E.
I432WO0DF2RDRDLEWISWLUF NC270E3
4346480509 bbras(dblwname.am
1011612017
Luis R. Lomas P.E.
FL No.: 62514
1 3/8" 1 /4"
MIN. EMBEDMENT
MIN. EMBEDMENT It . I
/D MIN. EDGE %/10 WOOD 3/16" ELCO
DISTANCE SCREW ULTRACON
SECT5796 5764 MULLION
WOOD FRAMING CLIP
OR 2X BUCK INTERIOR
BY OTHERS
EXTERIOR
MULLION INSTALLATION
WOOD B CONCRETE
ANCHORING NOTES:
1) FOR ANCHORING INTO CONCRETE USE 3/16" ELCO ULTRACON TAPCONS WITH SUFFICIENT
LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM
EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
2) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT
LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS
SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
3) FOR ANCHORING INTO METAL FRAMING USE #10 SMS OR SELF DRILLING SCREW WITH
SUFFICIENT LENGTH TO ACHIEVE A 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
4) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 SELF TAPPING SCREWS WITH SUFFICIENT
LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL.
LOCATE SCREWS 6" FROM EACH MULLION END AND 12" MAX. O.C. THEREAFTER. STAGGER
SCREWS AT EACH WINDOW.
5) FOR WINDOW UNITS ANCHORING SCHEDULE REFER TO WINDOW APPROVED INSTALLATION
INSTRUCTIONS.
6) ALL FASTENERS TO BE CORROSION RESISTANT.
7) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S
INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH
STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI.
C. METAL STRUCTURE — STEEL 18GA (.048") FY=33KSI/FU=52KSI OR
ALUMINUM 6063—T5 FU=30KSI .0625" THICK MINIMUM.
2 1/2"
MIN.
EDGE
DISTANCE
MASONRY/CONCRETE
BY OTHERS
METAL STRUCTURE
BY OTHERSfjI
/2" Mu
EDGE
DISTANCE
M
PENSIONS
RfY 06CRIPIION M1[ ppPROVFD
A REVISED INSTALLATION DETAILS O6/10/15 R.L.
8 REVISED INSTALLATION DETAILS 1 10/13/17 R.L
#10 SMS OR
SELF DRILLING
SCREW
SECT5796
CLIP INTERIOR
EXTERIOR
MULLION INSTALLATION
METAL STRUCTURE
650 WEST MARKET STREET
GRATZ. PA 17030
5764 HORIZONTAL MULLION
SINGLE AND TWIN WITH TRANSOM
INSTALLATION DETAILS
SIGNED: 1011612017
NTS " 03/06/12 "13 OF 3 "n1111101"
LRO6ERTOLOMASP.E Luis R. Lomas P.E.
Id WOODFORDRDLEWISldl1£,NC21013 FL No.: fi2514
451 M6 09 rlhmRs(DObmasO .
L. Roberto Lomas P.E. Engineering Evaluation Report
1432 Woodford Rd.
Lewisville, NC 27023 Report No.: 513321 B
434-688-0609
rllomas@lrlomaspe.com
Manufacturer: MI Windows & Doors
650 West Market Street SC,gN
Gratz, PA, 17030 O'f C &y%j)
Ucie
Product Line: Series 185 Aluminum Single Hung Window 36" x 84" —Impact L'Oi•...
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a). The product listed
herein complies with requirements of the Florida Building Code.
Supporting Technical Documentation:
1. Approval document: drawing number 08-02545 revision B, prepared, signed and sealed by Luis Roberto Lomas P.E.
2. Test report No.: E1729.01-109-47 signed and sealed by Michel D. Stremmel P.E.
Architectural Testing Inc., York, PA
AAMANVDMA/CSA 101/I.S.2/A440-08
Design pressure: t60.15psf
Water penetration resistance 9.19psf
3. Test report No.: E1729.02-109-47 signed and sealed by Michel D. Stremmel P.E.
Architectural Testing Inc., York, PA
ASTM E1886-05 and ASTM E1996-12
ASTM El886/ El996 Large Missile Impact, Level D, Wind Zone 3
ASTM E1886/ E1996 Cyclic Load Test, x55.Opsf design pressure
4. Anchor calculations, report number 513321-1, prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: t55.Opsf
• Maximum unit size: 36" X 84"
• Units must be glazed per ASTM El300-04/09, according with glazing details in approval drawing.
• This product is not rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in wind borne debris regions.
• Frame material to be Aluminum 6063-T5.
Installation:
Units must be installed in accordance with manufacturer's installation instructions and approval document, 08-02545
revision B.
Certification of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity
involved in the approval process of the listed product(s).
1of1
�II11111//�
* • 0,.5t251 ••
•
A • TAT OF •w�
��'P •. �OR10 •• \ ��
Luis R. Lomas, P.E.
FL No.: 62514
10/02/2017
NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL.
5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY
FASTENED TO MASONRY. CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF
THE ARCHITECT OR ENGINEER OF RECORD.
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR
GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL: EXTRUDED RIGID PVC.
12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 11 FOR GLASS DETAILS.
13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
ROsslaNs
DE RIMN wre "PROAD
A REVISED ANCHOR SPACING h CHARTS 0]/11 /16 R.L.
B REVISED CL455 10/02/1] R.L.
15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO
SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2
1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND
INSTALLATION DETAILS.
17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF
DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND
STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
DETAILS.
18. ALL FASTENERS TO BE CORROSION RESISTANT.
19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI.
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KS1/FU=52KS1 OR
ALUMINUM 6063—T5 FU=30KSI .048" THICK MINIMUM
TABLE OF CONTENTS
SHEET NO. DESCRIPTION
MI WINDOWS AND DOORS, LLC
650 WEST MARKET STREET
GRATZ. PA 17030-0370
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
36" X 84"— LMI
NOTES
1 I NOTES N.G. 08-02545 B
2 — 3 ELEVATIONS SG4E NTS DATE 12/09/2014 s6EET I OF 11
4 — 10 INSTALLATION DETAILS LRoeE COMAS R.E
1211412017
R. Lomas P.E.
No.: 62514
f
N
FR
HE
36" MAX
FRAME WIDTH
16"
2 MAX I� 0.0 �I 'I 2" MAX
MAX
O.C.
O /
4
4X
ME
GHT
/
/
uA
1
185ALUMINUM SINGLE HUNG WINDOW
EXTERIOR VIEW
FLANGE & FINLESS INSTALLATION
SEE CHART#1 FOR SMALLER UNITS REQUIRED ANCHO,
36" MAX
FRAME WIDTH
16"
2" MAX MAX ^- -- 2" MAX
D.C.
16"
MAX OO.C.
84"
MAX
FRAME /
HEIGHT /
uA
185 ALUMINUM SINGLE HUNG WINDOW
DESIGNER EXTERIOR VIEW
FLANGE& FINLESS INSTALLATION
SEE CHART #1 FOR SMALLER UNITS REQUIRED ANCHORS
DESIGNPRESSURE RATING
IMPACTRATING
t55.0PSF
LARGE
MISSILEIMPACT
MISSILE LEVEL AWING ZONE
NOTES:
1. MAXIMUM SASH SIZE: 34 1/2" X 36".
2. MAXIMUM SASH D.L.O.: 31 1/2" X 32 1/2"
3. MAXIMUM FIXED D.L.O.: 33 1/8" X 45"
RMSIONS
REV OESCRIPiION 'ATE -PR-In
A REVISED ANCHOR SPACING k CHARTS 11/11/11 R.L.
B REVSED GU S 1 10/02/17 R.L.
CHART #1 FLANGE A FINLESS INSTALLATION
Number of anchor locations
required
Frame
Frame
Width in
Height
18.00
24.00
30.00
3&00
(in)
Head
Jamb
Head
Jamb
Head
Jamb
Head
Jamb
2400
2
3
3
3
3
3
3
3
30.00
2
3
3
3
3
3
3
3
36.00
2
3
3
3
3
3
3
3
42.00
2
4
3
4
3
4
3
4
48.00
2
4
3
4
3
4
3
4
54.00
2
5
3
5
3
5
3
5
60.00
2
5
3
5
3
5
3
5
66.00
2
5
3
5
3
5
3
5
72.00
2
6
3
6
3
6
3
6
78.00
2
6
3
6
3
6
3
6
8400
1 2
6
3
6
3
6
1 3
6,
MI WINDOWS AND DOORS, LLC
650 WEST MARKET STREET
GRATZ. PA 17030-0370
I SERIES 185 ALUMINUM SINGLE HUNG WINDOW I
36" X 84"— LMI
FLANGE AND FINLESS ELEVATIONS
NTS 1-" 12/09/2014 1'N"'2 OF 11
L ROBERIO LOWS P.E.
1132 WOODFDAD RO LEWISWLtE, NO 2M3
434i660E0B 4bnus(3(rbmaspemm
: 1211412017
MIIII/
i .'L or/,
*"�Noy6/46� "•
Luis R. Lomos P.E.
FL No.: 62514
36" MAX
FRAME WIDTH
36" MAX
FRAME WIDTH
RMSIONS
REY oEscaiPnox
OARE APPR0.4'O
10"
10"
A REVISED ANCHOR SPACING & CHARTS
07/11/16 R.L.
2" MAX
MAX '{
2" MAX
2" MAX
MAX --{
2" MAX
a REVISED GLISS
10/02/1] R.L
O.C.
O.C.
L
L
10" MAX
O.C.
_�
O /
10" MAX
O.C.
84"
O /
CHART #2 FIN INSTALLATION
Humber of anchor locations required
18844"
/�
MAX
/
Frame
Framee WItlN (in)
FRAME
FRAME
Height
18.00 24.00 30.00 1
36.00
HEIGHT
HEIGHT
(in)
H85
Jamb HBS IJ..b HBS Jamb HBS
Jamb
.00
3
3 3 3 4 3
5 3
30
30.00
3
4 3 4 4 4
5 4
.00
4200
3
3
5 3 5 4 5
5 3 5 4 5
5 5
5 5
Q
'71LII7'
48,8.00
3
6 3 6 4 6
5 6
54.00
3
6 3 6 4 6
5 6
60.00
66.00
3
3
7 3 7 4 7
8 3 8 4 8
5 7
5 a
72.00
3
8 3 8 4 8
5 8
F878.00
3
9 3 9 4 9
5 9
400
3
9 3 9 1 4 1 9 1
5 1 9
SINGLE HUNG
185ALUMINUM
WINDOW
185 ALUMINUM
SINGLE HUNG
WINDOW
EXTERIOR VIEW
DESIGNER EXTERIOR VIEW
FININSTALIATION
FININSTAUATION
SEE CHARTS2
FOR SMALLER UNITS REQUIRED
ANCHORS
SEE CHART#2
FOR SMALLER UNITS REQUIRED
ANCHORS
DESIGN PRESSURE RATING
IMPACTRATING
t55.OPSF
LARGE
MISSILE IMPACT
M/SS11E LEVEL D, WIND ZONE
INOTES:
1. MAXIMUM SASH SIZE: 34 1/2" X 36".
2. MAXIMUM SASH D.L.O.: 31 1/2" X 32 1/2"
3. MAXIMUM FIXED D.L.O.: 33 1/8" X 45"
MI WINDOWS AND DOORS, LLC
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
36" X 84"— LMI
FIN ELEVATIONS
umw OWG NO.
N.G. 08-02545
3C NTS IGATE 12/09/2014 IS8003 OF 11
L ROBERTO LOMAS RE
I432 WOODFORO RD LEWISVILLE, NC 27023
434E88-0 09 46nurs@/Romaq a.
SIGNED: 1211412017
Luis R. Lomas P.E.
FL No.: 62514
RL SIGNS
1 /2" MIN REv DESCRIPDON OMc APPRoAD
WOOD FRAMING
EDGE DISTANCE
A REVISED ANCHOR SPACING &CHARTS 07/11/16 R.L.
— —
OR 2% BUCK B I REVISED G1A55 10/02/17 R.L.
BY OTHERS
1 1/4" MIN.
EMBEDMENTT
BACKER ROD
& APPROVED 1/4" MAX.
SEALANT SHIM SPACE
#10 WOOD SCREW
INTERIOR
EXTERIOR k
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
SILL TO BE SET
IN A BED OF
APPROVED
STRUCTURAL
SEALANT
1/4" MAX.
SHIM SPACE
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
NOTES.,
1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWN FOR CLARITY.
2. PERIMETER AND ✓OIMTSEALANTBYOTHERS TO BE
DESIGNED INACCORDANCE WIT74ASTME2112
1 1/4" MIN. 1/4" MAX.
EMBEDMENT SHIM SPACE
1
1/2" INTERIOR
MIN
EDGE
DISTANCE
#10 WOOD
SCREW
WOOD FRAMING
OR 2X BUCK BACKER ROD
BY OTHERS It APPROVED EXTERIOR
SEALANT
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
1211412017
6ii WINDOWS
650 WEST MA D ET STREET LLC ```\\\5111R. L !0/'117j��i
GRATZ, PA 17030-0370 •��G EN,gt.'4s
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
36" % 84"— LMI !-yu*_`•, ��AT b6cOFcO.•t *l—
FLANGE INSTALLATION DETAILS
w,TE 12/09/2014 ISHM4 OF 11 " 111111110T"
LHOSERTOLOMASP.E' Luis R. Lomas P.E.
1192W000WRO flO LEWISV/LLE, NCD023 FL No.: 62514
A90E49O609 r1lDrnas(R�LNmasm.ovn
METAL
STRUCTURE
BY OTHERS
APPROVED
SEALANT
1/2" MIN
1-T EDGE DISTANCE
El /4" MAX.
SHIM SPACE
#10 SMS OR
SELF DRILLING
SCREW
INTERIOR
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
MET/
STRUCTUF
BY OTHEF
SILL TO BE SET
N A BED OF
APPROVED
STRUCTURAL
SEALANT
1/4" MAX.
SHIM SPACE
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
NOTES:
I. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
NOTSHOWN FOR CLARITY.
2. PERIMETERANDJO/NTSEALANTBYOTHERSTO BE
DESIGNED IN ACCORDANCE IWTHASTM E2112
#10 SMS OR
SELF DRILLING
SCREWS
HEV o¢C0.IPIION MT I MFRIMD
A REVISED ANCHTSPACING & CHARTS 07/11/16 R.L.
B REVISED GI SS 10/02/17 R.L
/4" MAX.
SHIM SPACE
INTERIOR
METAL EXTERIOR
STRUCTURE BACKER ROD
BY OTHERS & APPROVED
SEALANT
JAMB INSTALLATION DETAIL
METAL STRUCTUREINSTALLA77ON
MI WINDOWS AND DOORS, LLC
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
36" X 84"— LMI
FLANGE INSTALLATION DETAILS
N.G. 08-02545 B
3 A NTS JDATE 12/09/2014 ISHEU5 OF 11
L ROBERTO LOMAS P.E.
14921O 09ORD .Ckk/LLE NC27029
A30�699�0699 Nbmas@LW�.mm
SIGNED: 1211412017
Luis R. Lomas P.E.
FL No.: 62514
CONCRETE/MASONRY
BY OTHERS
OPTIONAL IX BUCK
SEE NOTES 3 — 7
SHEET 1
BACKER ROD
& APPROVED
SEALANT
2 1/2" MIN.
EDGE DISTANCE
•!a:. ;.
e 1 1/4" MIN.
°°e ' •' a' EMBEDMENT
1/4" MAX.
SHIM SPACE
3/16" TAPCON
INTERIOR
EXTERIOR
BACKER ROD
SILL TO BE S
APPROVED
BED
IN A BED OF
SEALANT
APPROVED
STRUCTURAL
OPTIONAL 1X BUCK
SEALANT
SEE NOTE 3 — 7
SHEET 1
1/4" MAX.
SHIM SPACE
CONCRETE/MASONRY
BY OTHERS
^..
a
°
VERTICAL CROSS SECTION
CONCRETEIMASONRY INSTALLATION
RNSIONS
DESLRIPLION PATE MPROVED
REVISED ANCHOR SPACING & CHARTS 07/11/16 1 R.L.
REVSED GLA96 1 10/02/17 1 R.L.
1 1/4" MIN. 1/4" MAX.
EMBEDMENT SHIM SPACE
CONCRETE/MASONRY
BY OTHERS • °
3/16" TAPCON
v I INTERIOR
2 1 /2"
MIN.
EDGE
DISTANCE
1 E
XTERIOR
OPTIONAL 1X BUCK
SEE NOTES 3 — 7
SHEET 1 JAMB INSTALLATION DETAIL
CONCRETE4MSONRY INSTALLATION
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
NOTSHOWNFORCLAnITY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE
WRHASTME2112
SIGNED: 1211412017
MI AND LLC
Rl lllfllol�77XX/i
650DOWS
W WEST MARKET STREET
GRATZ, PA 17030-0370
`\``S \Xs
` r••�NGENyF;9ip
SERIES 185 ALUMINUM SINGLE HUNG WINDOW*•
0..826
36" X 84"— -MI
— ;, f��'1(T(ir�]Xt�+�'
FLANGE INSTALLATION DETAILS
gip; STATE OF •Lyj
%OFS;°(ORIOQ; GN
om":
0" NO.
RLv
oa 50 �sas
a
ii7js10NA11��\\`�
s W E
NTS 12/09/2014 6 OF 11
LROBERTOLOMASP.E
Luls R. Lomas P.E.
faaz vr000wRORDLEvnsvnLE. nc27Dza
aucsaDsas nmmas®mmusce.rom
FL No.: 62514
1/2" MIN
EDGE DISTANCE
WOOD FRAMING
OR 2X BUCK
BY OTHERS
BACKER RD /4" MAX.
O--�
& APPROVED 1
SEALANT SHIM SPACE
`- #10 WOOD SCREW
INTERIOR
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
TILL TO BE SET
N A BED OF
\PPROVED
iTRUCTURAL
iEALANT
1/4" MAX.
SHIM SPACE
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
NOTES.-
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWNFORCLARRY.
2. PERIMETERANDJO/NTSEALANTBYO7HERSTOSE
DESIGNED IN ACCORDANCE WITH ASTM E2112
1 1/4" MIN.
EMBEDMENT
1
1 /2"
MIN
EDGE
DISTANCE
f g10 WOOD
SCREW /
NEWSIONS
REV OESCRIP110N ppiE MPRWED
A REVISED ANCHOR SPACING & CHARTS 07/11/16 R.L.
B REVISED CLASS 10/02/17 R.L.
1/4" MAX.
SHIM SPACE
INTERIOR
WOOD FRAMING EXTERIOR
OR 2X BUCK BACKER ROD
BY OTHERS & APPROVED
SEALANT
JAMB INSTALLATION DETAIL
WOOD FRAMING 0R2X BUCKINSTALLATION
MI WINDOWS AND DOORS, LLC
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
36" X 84"— LMI
FINLESS INSTALLATION DETAILS
x: DWG NO.
OB-02545
' NTS — 12/09/2014 S"u-'7 OF 11
L RODERTO LOWS P.E.
14 WOODFORD RD LEWISVILLE NO27023
1 686 609 ebm.Wmo ,s.
SIGNED: 1211412017
Luis R. Lomas P.E.
FL No.: 62514
METAL
STRUCTURE
BY OTHERS
APPROVED
SEALANT
B
1/2" MIN
EDGE DISTANCE
1/4" MAX.
SHIM SPACE
#10 SMS OR
SELF DRILLING
SCREW
INTERIOR
EXTERIOR
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
NOTES:
1.INTERIORAND EXTERIOR KNISHES, BYOTHERS,
NOTSHOWNFOR CLARITY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE
SILL TO BE SET
IN A BED OF
APPROVED
STRUCTURAL
SEALANT
1/4" MAX.
SHIM SPACE
REVISIONS
DESCRIPTION Mn MPROVFD
RENSEO ANCHOR SPACING k CHARTS 07/11/16 R.L.
REVISED GLASS 10/02/17 R.L.
1/4" MAX.
SHIM SPACE
#10 SMS OR
SELF DRILLING INTERIOR
SCREWS
1/2"
MIN.
EDGE
DISTANCE
EXTERIOR
METAL BACKER ROD
STRUCTURE & APPROVED
BY OTHERS SEALANT
JAMB INSTALLATION DETAIL
METAL STRUCTUREINSTALLATION
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
36" X 84"— LMI
FINLESS INSTALLATION DETAILS
DP N: MG NO. FEV
N.G. 1 08-02545 B
SDae NTS pA1 12/09/2014 sH� 8 OF 11
1211412017
Luis R. Lomas P.E.
FL No.: 62514
_ 2 1/2" MIN.
RENSIONS
EDGE DISTANCE
REV DESCRIPTION
M1E MPROKD
CONCRETE/MASONRY
a
A REVISED ANCHOR SPACING & CHARTS
07/11/16 R.L.
BY OTHERS
`°.4
°
n'
B REVISED cuss
10/02/17 R.L.
n
1 1/4" MIN.
OPTIONAL 1X BUCK
°'
EMBEDMENT
SEE NOTES 3 — 7
�
1 1/4" MIN.
SHEET 1
,
EMBEDMENT
CONCRETE/MASONRY
1/4" MAX.
BY OTHERS OPTIONAL 1X BUCK
BACKER ROD
SHIM SPACE
SEE NOTES 3 — 7
SHEET 1
& APPROVED
,• a
SEALANT
3/16" TAPCON
3/16" TAPCON - ° 1/4" MAX.
SHIM SPACE
INTERIOR
INTERIOR
2 1/2"
MIN. -
EDGE
EXTERIOR
DISTANCE
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
SILL TO BE SET
CONCRETE/MASONRYINSTALLATION
IN A BED OF
BACKER ROD
APPROVED
& APPROVED
STRUCTURAL
SEALANT
SEALANT
NOTES.
EXTERIOR FINISHES, BYOTHERS,
OPTIONAL 1X BUCK
1/4" MAX.
NOTSHOWNFORCLARITY.
SEE NOTE 3 — 7
SHIM SPACE
2PERIMETERANDJOINTSE4LANTBYOTHERSTOBE
SHEET 1
DESIGNED NACCORDANCE WI7HAS7ME2112
SIGNED: 1211412017
MI WIN650DOWT LLC
1R1.
CONCRETE/MASONRY
BY OTHERS
"
MARKETDDOOREET
`\``'Nl
ENSF;9iP
GRATZ, PA 17030-0370
`�••yVG
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
_�-,�12617t'•�'
FINLESS INSTALLATION DETAILS
lj AT GF ty�
•
i��•�• ACO lOa;'�
CROSS
REV
DRAWN: OWD No.VERTICAL 6 B
'�SS
CONCCRETETEJMASORYINSTALLA77ON
Sr mm SOHE0.95
i�NAL1 EO6
NTS 12/09/2014OF 11
LROBERIOLOMASP.E
LD15 R. Lomas P.E.
1472WDODFORDRDLEWISVID.ENC2=3
FL No.: 62514
1316380609 Namas®bbmasp .
PMSIOxS
1 1/4- MIN.
P[v JMCRIPiION
APPROVED SEAIANT
EM EDMENT
A REVISED ANCHOR SPACING k CHARTS
BEHIND FIN
WOOD
FRAMING
a REVISED GI -ASS
BY OTHERS
1/4" MAX.
SHIM SPACE
7/16" MIN j
EDGE DISTANCE
/j8 WOOD SCREW
" MAX
WOOD FRAMING
BY OTHERS SHIM SPACE
WOOD
SC
/ SCREW
1 IA=
INTERIOR
MEMBE
EXTERIOR
INTERIOR APPROVED
SEALANT
BEHIND FlN
7/16" MIN EXTERIOR
EDGE DISTANCE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR2X BUCKlASTALLAT/ON
0AIE MPPO
11/16 R.L.
'02/17 1 R.L.
NOTES:
1/4" MAX
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
`
r SHIM SPACE
NOTSHOWNFORCLARTTY.
2. PERIMETERAND JOINT SEALANT BYOTHERSTO BE
—�
DESIGNED IN ACCORDANCE WT M ASTM E2112
SIGNED: 1211412017
7/16" MIN
EDGE DISTANCE
MI WINDOWS AND DOORS, LLC
6GRATZ,50 S MARKET T
X�XY111111NII,,A
#8 WOOD
WOOD
PA 17030 0370T
',,*Cl���`\J\o.. ''9///i
y' SF
SCREW
FRAMING
VO •�
1 1/4" MIN.
BY OTHERS
SERIES 185 ALUMINUM SINGLE HUNG WINDOW
*• 0 5 *�
APPROVED EMBEDMENT
36" X 84'— LMI
'
q1
SEALANT
FIN INSTALLATION DETAILS
�p AT OF ;
BEHIND FIN VERTICAL CROSS SECTION
•
��'�••'P(OR10P
WOOD FRAMING OR 2X BUCKINSTALLATION
oxwwN: owc NO. PEV
N.G. 08 B
/IFS • • • G
//qS/ONA'tE�O��
5045
Dore
NTS 12/09/2014 10 OF 11
L flOBERTOWMASP.E
Luis R. Lomas P.E.
1132 WOOOPoflO ROLEW/SVPIF NC2T09
FL No.: 62514
asrceeosos mm�xsC�Mmxa�na.mx
APL
2 3/16"
13/16'
FLANGE FRAME HEAD
CM-18501
ALUMINUM 6063-T5.050' THICK
2 5/16"
3 3/8"
FLANGE FRAME SILL
CM-18502
ALUMINUM 6063-T5.055' THICK
11 V 5/�8" r
1 3
LOCKRAIL/STILE
CM-16505
ALUMINUM 6063.T5.062- THICK
GLAZING BEAD
CM-18535
RIGID PVC.050'THICK
FLANGE FRAME JAMB
CM-16503
ALUM/ NUM 6063-T5.050' THICK
2 5/16" —1
2 13/1 '
FINLESS FRAME SILL
CM-18554
ALUMINUM 601 THICK
5l
FINLESS FRAME HEAD
CM-18553
ALUMINUM 6063-T5.050'THICK
2 3/16'
EFINLESS FRAME JAMB
CM-18513
ALUMINUM 61050'THICK
2 5/16"
2 3/16"
3 3/4"
2 5/1fi"
FIN FRAME SILL FIN FRAME HEAD
CM-18509 CM-Imm
ALUMINUM 6053-T5.055-THICK ALUMINUM 6063-T5.050'THICK
1 7/16'•
1 1/6
2 51/16'
J— J�
SASH BOTTOM RAIL MEETING RAIL
CM-18555 CM-18504
ALUMINUM 6063-T5.050'TH/CK ALUMINUM 6063-T5.055'THICK
�11 3/8"
1s/16"
-I SASH STILE
CM4B507
ALUMINUM 6063-T5.050' THICK
2 3/8'•
2 3/16'
FIN FRAME JAMB
CM-18510
ALUMINUM 6063-T5.050'THICK
RMSIONS
DESCRIPTION
REVISED ANCHOR SPACING h CHARTS
REVISED GLASS
5/8"
1/8" ANN.
fE MPIR D
t1 /16 R.L.
62/1] 1 R.L.
3/32 ANN.
.090 EVE BY KURARAY
— 3/32" ANN,
EXTERIOR II METAL REINFORCED
BUTYL SPACER
J INTERIOR
7 /2" BITE SILICONE
SEALANT
SETTING BLOCK
GLAZING DETAIL
MI WINDOWS AND DOORS, LLC
I SERIES 185 ALUMINUM SINGLE HUNG WINDOW I
36" X 84"— LMI
COMPONENTS
O RP.wN: DwU NO,
N.G. 08-02545 B
SCAE NTS -1E 12/09/2014 SHEET 11 OF 11
L. ROBERTOLOMAS R.E
1211412017
Luis R. Lomas P.E.
FL No.: 62514
►�o � - dAA
CREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer:
TAMKO BUILDING PRODUCTS
220 West Street
Joplin, MO 64801
(417)624-6644
Manufacturing Plants:
Joplin, MO
Phillipsburg, KS
Frederick, MD
Dallas, TX
Tuscaloosa, AL
Quality Assurance:
UL LLC (QUA9625)
SCOPE
Certificate of Authorization No. 29824
17520 Edinburgh Dr
_Tampa, FL33647
(813)480-3421
FLORIDA BUILDING CODE, C EDITION
Issued Septemll, 25,
9
ERECEVED�'9
mitting I
Category: Roofing
Subcategory: Asphalt Shingles
Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1
Properties: Physical properties, Wind Resistance, Wind Driven Rain
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction. Materials Technologies (TST5878)
TAP-043-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-051-02.01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-054-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-114-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-117-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-130-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-131-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-165-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-280-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-303-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-307-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP-314-02-01 Rev 2
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
TAP315-02-01
ASTM D 6381
2008(2013)el
PRI Construction Materials Technologies (TST5878)
TAP-317-02-01
TAS 100
1995
UL LLC (TST9628)
UL LLC (TST9628)
02NK9507
04NK24366
ASTM D 3161
ASTM D 3462
2016
2010A
UL LLC (TST9628)
OSNK28006
ASTM D 6381
2008(2013)el
UL
ASTMM D D 7158
2011
0
UL LLC (TST9628)
06NK03898
ASTM D 3161
ASTM D 3462
2016
2010A
UL LLC (TST9628)
08CA59132
ASTM D 3161
2016
UL LLC (TST9628)
09NK07896
ASTM D 3161
2016
Uj
UL LLC (TST9628)
10CA50498
ASTM D 3462
ASTM D 3462
2010A
2010A
UL LLC (TST9628)
IOCA64882
ASTM D 3161
2016
UL LLC (TST9628)
11 NK14014
ASTM D 3161
2016
ASTM D 3462
2010A
UL LLC (TST9628)
12CA24551
ASTM D 3161
2016
UL LLC (TST9628)
4786110543
ASTM D 6381
2008(2013)el
UL LLC (TST9628)
4787043752
ASTM D 3161
2016
UL LLC (TST9628)
4787148748
ASTM D 7158
2011
ASTM D 3161
2016
ASTM D 3462
2010A
CREEK Technical Services LLC (ANE11669)
TBP15001.3
Calculations
2017
TBP15001.4
FLA8355:=,R`r^—�
Page
Of 11
This evaluation report is provided for State of Florida product approval-under-Rutet6l G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
I
CREEK TAMKO BUILDING PRODUCTS
CREEK Asphalt Shingles
TECHNICAL SERVICES, LLC
PRODUCT DESCRIPTION
Elite GlassSeal® 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 3-tab
(Frederick, Joplin & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass -Seal 12-1/4" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H self-sealing, 34ab
(Frederick & asphalt shingle with fiberglass mat coated on both sides with asphalt and surfaced with
Tuscaloosa) ceramic granules complying with ASTM D 3462.
Glass -Seal 12-1/4" x 36", ASTM D 7158, Class H self-sealing, 3-tab asphalt shingle with fiberglass
(Joplin) mat coated on both sides with asphalt and surfaced with ceramic granules complying
with ASTM D 3462. Shincles shall be used in the non-HVHZ only.
Hentag _ _,
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Da II s,;Frteder ck�
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Jophli .P.fiillipsbu�g &
complying with ASTM D 3462.
usca(oosa)
Heritage®Premium
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas, Frederick,
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
Phillipsburg &
complying with ASTM D 3462.
Tuscaloosa)
Heritage®.Premium
12" x 36", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Frederick)
laminated architectural asphalt shingle surfaced with mineral granules complying with
-
ASTM D 3462.
Heritage® Vintage®
17-1/2" x 40", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass reinforced,
(Phillipsburg)
laminated architectural asphalt shingle surfaced with mineral granules complying with
ASTM D 3462.
Heritage® Woodgate
13-1/4" x 39-3/8", ASTM D 3161, Class F and ASTM D 7158, Class H fiberglass
(Dallas & Frederick)
reinforced, laminated architectural asphalt shingle surfaced with mineral granules
complying with ASTM D 3462.
Heritage® Woodgate
12" x 36-3/8", ASTM D 3161, Class F fiberglass reinforced, laminated architectural
(Frederick)
asphalt shingle surfaced with mineral granules complying with ASTM D 3462. Shingles
shall be used in the non-HVHZ only.
Hip and Ridge Shingles
12-1/4" x 12", ASTM D 3161-, Class F fiberglass reinforced, hip and ridge asphalt
(Frederick & Joplin)
shingle surfaced with mineral granules complying with ASTM D 3462.
Vintage® Hip and Ridge
12" x 12", ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle
(Phillipsburg)
surfaced with mineral granules complying with ASTM D 3462.
TBP15001.4
Of 11
This evaluation report is provided for State of Flonda product approval under Rule bi UZU-3. 1 he manufacturer snail notny URLLK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
INSTALLATION
Elite GlassSeal®
Basic Wind Speed (Vw):
(Frederick, Joplin &
Basic Wind Speed (V.m)
Tuscaloosa)
Deck (HVHZ):
&
Glass -Seal
(Frederick, Joplin (Non-
HVHZ) & Tuscaloosa)
Deck (Non-HVHZ):
Undedayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ)
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements. -
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-1/8 inch exposure in accordance with RAS
115 and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5-1/8-inch exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
)..
Figure 1. Elite Glass -Seal & Glass -Seal
4 Nail Pattern (Non-HVHZ only)
Butt Edge
Figure 2. Elite Glass -Seal & Glass -Seal
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 3 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES,
LLC
Heritage®
Basic Wind Speed (V,n):
(Dallas, Frederick, Joplin,
Basic Wind Speed (Vnd):
Phillipsburg & Tuscaloosa)
Deck (HVHZ):
Heritage® Premium
(Dallas, Frederick
Phillipsburg & Tuscaloosa)
Deck (Non-HVHZ):
Heritage® Woodgate
(Dallas & Frederick)
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max.194 mph
Max.150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15132 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5-5/8 in. exposure in accordance with RAS
115 and manufacturer's published installationinstructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5-5/8 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
NAIL ZONE
BOND
EXPOSU RE 6-6/8"
12-11211-+-12-3/8" --+- 12-1/21`�--1"
Figure 3. Heritage®, Heritage® Premium, and Heritage® Woodgate (Dallas)
4 Nail Pattern (non-HVHZ only)
FASTENERS
Figure 4. Heritage® & Heritage® Premium
6 Nail Pattern
ZONE
BOND
5-5/8°
TBP15001.4 FL18355-R4 Page 4 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
TAMKO BUILDING PRODUCTS
Asphalt Shingles
M'CommonBond
Figure 6. Heritage®, Heritage® Premium, & Heritage® Woodgate
Alternate 6 Nail Pattern
Figure 7. Heritage® (Tuscaloosa)
Expanded Nail Zone
Nail patterns from Figures 3, 4, and 6 may be placed in the nail zone as described above
TBP15001.4 FL18355-R4 I
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall ni
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this re
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes
specifically addressed herein.
5 of 11
is valid.
are not
®CREEK
TECHNICAL SERVICES, LLC
Heritage® Premium Basic Wind Speed (Vvu):
(Frederick) Basic Wind Speed (V.w):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max.194 mph
Max.150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12. .
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
5°
12° -►i-11"-►� �-1°
Figure 8. Heritage® Premium (Frederick)
4 Nail Pattern (non-HVHZ only)
L ZONFJ
AMON BOND
NAIL ZONE/
COMMONSOND
SURE 5°
1.--1 a
Figure 9. Heritage® Premium (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 6 of 11
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Heritage® Woodgate
(Frederick)
5-1/2"
1
Basic Wind Speed (V"n):
Basic Wind Speed (Vase):
Deck (Non-HVHZ):
Undedayment:
Min. slope:
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturers application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "4 Nail
Pattern" or "6 Nail Pattern" detailed below.
ZONE!
IMN BOND
r`1T
EXPOSURE Y
■A,
1"-q �- 11"—r�---12�/8"-- - 11" —' �-1"
Figure 10. Heritage® Woodgate (Frederick)
4 Nail Pattern (non-HVHZ only)
5•
F!
BOND
1"-1111 �9.1/2" 9.3/8"�►� 8 8.1l2" -4 104.
Figure 11. Heritage® Woodgate (Frederick)
6 Nail Pattern
TBP15001.4 FL18355-R4 Page 7 of 11
This evaluation report Is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
Heritage® Vintage® Basic Wind Speed (V a):
(Phillipsburg) Basic Wind Speed (V„d):
Deck (HVHZ):
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation (HVHZ):
Installation (Non-HVHZ):
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max.194 mph
Max.150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements. Refer to
the manufacturer's application instructions when installing
shingles at slopes greater than 21:12.
Installed with 5 in. exposure in accordance with RAS 115
and manufacturer's published installation instructions.
Shingles shall be attached using "6 Nail Pattern" detailed
below.
Installed with 5 in. exposure in accordance with FBC
requirements and manufacturer's published installation
instructions. Shingles shall be attached using either "5 Nail
Pattern" or "6 Nail Pattern" detailed below.
tpo
rbtd
Figure 12. Heritage® Vintage®
5 Nail Pattern (non-HVHZ only)
Figure 13. Heritage® Vintage
6 Nail Pattern
FL18355-R4
8 of 11
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product atttibutes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
Hip & Ridge Basic Wind Speed (V,a):
(Frederick & Joplin) Basic Wind Speed (Ve,d):
Deck (HVHZ):
TBP15001.4
Deck (Non-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max. 194 mph
Max. 150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in. plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15/32 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5-1/8 inch exposure in accordance with the
FBC and manufacturer's published installation instructions.
The direction of the exposed end shall be away from the
prevailing wind.
Direction of prevailing wind
exposure
Figure 1
Fastener
<S,�n
Figure 2
Figure 14. Hip & Ridge (Frederick & Joplin)
FL18355-R4
exposure
9 of 11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
Vintage® Hip & Ridge Basic Wind Speed (Vmt):
(Phillipsburg) Basic Wind Speed (V„a):
Deck (HVHZ):
Deck (Nan-HVHZ):
Underlayment:
Min. slope:
Installation:
TAMKO BUILDING PRODUCTS
Asphalt Shingles
Max.194 mph
Max.150 mph
In accordance with FBC requirements;
Solidly sheathed min. 19/32 in, plywood or wood plank for
new construction; Min. 15/32 in. plywood existing
construction.
In accordance with FBC requirements;
Solidly sheathed min. 15132 in. plywood or wood plank for
new construction; Min. 7/16 in. OSB existing construction.
In accordance with FBC requirements.
2:12 and in accordance with FBC requirements.
Installed with 5 inch exposure in accordance with the FBC
and manufacturer's published installation instructions. The
direction of the exposed end shall be away from the
prevailing wind.
Direction prevailing wind
n]
exposure
Figure 1
/I Fastener
Figure 2
o" exposure
rrgure s
Figure 15. Vintage® Hip & Ridge (Phillipsburg)
TBP15001.4
11
This evaluation report is provided for State of Flonda product approval under Rule 61G20.3. The manufacturer shall notify GREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the,duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
® CREEK TAMKO BUILDING PRODUCTS
Asphalt Shingles
TECHNICAL SERVICES, LLC
LIMITATIONS
1) Fire Classification is not within the scope of this evaluation.
2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ.
4) Classification to ASTM D 7158 applies to exposure B & C with a building mean roof height of 60-ft or less.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underiayment application. -
6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the
deck.
7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and code compliant detail shall prevail.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 61h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
tttiIIII
%%%.. Rpro.
r� C E N j* ��s 2017.09.25
No 74021 % ----:11:31:41
:0 STATE OF _04t0
0
r
;off O R t O P: �_Zachary R. Priest, P.E.
Florida SS;ONq ��, OrganiationNo.Registration No. 1 ANE11669
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor Wil acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor Wil acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT
TBP15001.4
11
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.