Loading...
HomeMy WebLinkAboutKSM REPORTi117iYi KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net MELBOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 May 2, 2019 mct-tiVED LMAY 13 2019 I LE COPY Gonzalo Zamudio ST, LuCle County, psrmittl., 2605 Chesterfield Drive — - _.. Fort Pierce, FL 34982 SCANNED BY Re: 3707 Arnold Road St. Lucie County Ft. Pierce, Florida Permit #: KSM Project #: 190694-2d hbk Dear Mr. Zamudio: As you requested, an on -site visit was made to the above referenced site to determine the degree of compaction of the foundation soils under the house pad for the final lift. Since the house pad was in place at the time of our visit, the following method was used to determine the in -place density. 1. At locations around the exterior of the foundation, the soil was removed parallel to the bearing grade of the footer and nuclear density readings taken. 2. At random locations around the exterior of the footer, a Brainard-Killman model S-214 static cone penetrometer was used to measure the soil resistance beneath the bearing grade of the footer. Findings: Nuclear density, readings indicate that the degree of compaction ranged from 97.8 to 98.8 percent of its modified Proctor value. Penetrometer readings indicate that the filled soils to be generally firm. The soil compaction report along with our penetrometer readings is attached. Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 i%L-1PJ M KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 www.ksmengineering.net SG'ANf ff. BOURNE (321) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET BY T. LUCIE (772) 229-9093 C.A.: 5693 FAX (772) 589-6469 St. Lucie County 3707 Arnold Road -2- May 2, 2019 Ft. Pierce, Florida Based upon the field data obtained, it is our professional opinion that the compaction exceeds 95 percent of its modified dry Proctor. We trust the findings in our investigation are clear and understandable. If any n is needed, please contact our office. Email to: gonzalozamudio@gmail.com Contractor must submit original signed and sealed copy to the Building Department. Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 L%IJAVL KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM CH (5 1) 845-7445 www.ksmengineering.net SCAN ELBO (321) 768-8488 FAX 561 C.A.: 5693 E-Mail: KSM@KSMENGINEERING.NET St ay ZbUCIE FAX (772) 589-6469 SOIL COMPACTION REPORT �UCfe Coen ASTM D 1557 and ASTM D 2922 ty DATE TESTED PERMIT # CONTRACTOR JOB LOCATION May 1, 2019 Gonzalo Zamudio 3707 Arnold Road Ft. Pierce, Florida, Florida ITEM TESTED Compacted Foudnation Fill - Final Lift TEST LOCATION OF SAMPLE 2. South 3. West 4. North Soil Description: Brown Sand In Place Moisture 6.7 Percent Optimum Moisture: 12.0 Percent Max. Dry Density: 109.0 P.C.F. KSM JOB # : 190694-2d/MH/ct DEPTH PEN DRY MAX. DRY PERCENT READ DENSITY PROCTOR VALUE COMPACTION 12" - 24" 50 107.7 109.0 98.8 " 50 106.8 98.0 50 107.5 98.6 50 106.6 97.8 @ Test Locations The Density & Penetrometer Readings Indicate the Degree of Compaction Meets Minimum Required for 110.0 I I I I I W I I I I I I E I I I I I I G 109.0 J_..—. �_.._.�._.. _..—�..—.. �..—.._ H I I I I I I T I I I I I I I I I I P 108.0 }-.._.�_.. .f_.._{._.._j.. .. �..—.._ C I I I I I I I I I I I F I I I I I 107.0.._.�_.._.f_..—�._.._i._..,.._.._ D I I I I I I R I I I I I I Y 106.0 �.._.�—.._.�_..—�._.._;._.. �..—..� 9 10 11 12 13 14 15 Moisture - % of Dry Weight Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366 5oe W C� 1 A i%L"31v KEENER, SCHLEICHER & MacWILLIAM ENGIfjI�IN INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, 3 Ftff 7 qr S A ) 58 INC. . PALM BEACH (561) 845-7445 www.ksmengineering.net E (3 1) 768-8488 FAX (561) 845-8876 E-Mail: KSM@KSMENGINEERING.NET SCgNN�.$T. LUCIE (772) 229-9093 C.A.: 5693 St Cu BY CI FAX (772) 589-6469 SOIL COMPACTION REPORT Cie County ASTM D 1557 and ASTM D 2922 DATE TESTED February 19, 2019 KSM JOB # : 190694-1 d/SS/cv PERMIT# \°�pl.pygcd RECEIVED CONTRACTOR Gonzalo Zamudio JOB LOCATION 3707 Arnold Road FEB 2 5 2019 Fort Pierce, Florida ST. r,ucle County, Permitting ITEM TESTED Compacted Foundation Fill for the House Pad TEST LOCATION DEPTH PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. N.E. 0" - 12" 39 105.2 109.0 96.5 2. S.E. 37 104.4 95.8 3. Center 42 107.3 98.4 4. S.W. 44 108.2 99.3 5. N.W. 41 106.7 97.9 Soil Description: Brown Sand In Place Moisture: 8.8 Percent Optimum Moisture: 12.0 Percent Max. Dry Density: 109.0 P.C.F. @ Test Locations The Density & Penetrometer Readings Indicate the —Degree-of-Compaction Meets — 110.0 I I I I I W E j I I I I I G 109.0L.._ .�—..—�.—.. _..� ..—..._. H I I I I I I T I I I I I I P j I 1o8.0 I I C j I I I I F 107.0-- D R I I I I I I Y 106.0 4—.._.�—..—�._..�.._.. ..—. �_..- 9 10 11 12 13 14 15 Moisture - % of Dry Weight Ronald G. Keller, P.E.: 37293 / SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366